15
Compliance Certification Services Inc. Report No: 90626003-MlL(RS103) Date of Issue: August 22, 2010 MILSTD461E/F TEST REPORT For 19" Military LCD Monitor Model Number: WMRM919 Trade Name: iTech Issued to iTech Company LLC 41758 Christy Street, Fremont CA 94538 USA Issued by Compliance Certification Services Inc. No. 11, Wugong 6 ,h Rd., VVugu Industrial Park Taipei Hsien 248, Taiwan http://www.ccsemc.com.rw [email protected] Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Sen'ices Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 Total Page: 15 Rev. 00

MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

Compliance Certification Services Inc. Report No: 90626003-MlL(RS103) Date of Issue: August 22, 2010

MILSTD461E/F

TEST R E P O R T

For

19" Military LCD Monitor

Model Number: WMRM919

Trade Name: iTech

Issued to

iTech Company LLC 41758 Christy Street,

Fremont CA 94538 USA

Issued by

Compliance Certification Services Inc. No. 11, Wugong 6,h Rd., VVugu Industrial Park

Taipei Hsien 248, Taiwan http://www.ccsemc.com.rw

[email protected]

Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Sen'ices Inc. This document may be altered or revised by Compliance Certification

Services Inc. personnel only, and shall be noted in the revision section of the document.

Page 1 Total Page: 15 Rev. 00

Page 2: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

ccs Compliance Certification Sennces Inc. Report No: 90626003-MIL(RS 103) Dale of Issue: August 22, 20 ] 0

TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION 3

2. EUT DESCRIPTION 4

3. TEST METHODOLOGY 5

4. INSTRUMENT AND CALIBRATION 5

4.1 MEASURING INSTRUMENT CALIBRATION 5 4.2 MEASUREMENT EQUIPMENT USED 5

5. FACILITIES AND ACCREDITATIONS 6

5,1 FACILITIES 6

6. SETUP OF EQUIPMENT UNDER TEST 7

6.1 SETUP CONFIGURATION OF FUT 7 6.2 PHOTOGRAPHS OF EUT 7 6.3 SUPPORT EQUIPMENT 7 6.4 TEST SETUP 7

7. MIL STD461E/F REQUIREMENTS 8

7.1 RS103, RADIATED SUSCEPTIBILITY, ELECTRIC, 2 MHZ TO 40 GHZ 8

8. APPENDIX I PHOTOGRAPHS OF TEST SETUP 15

Page 2 Rev. 00

Page 3: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

,ccs Compliance Certification Services Inc. Report No: 90626003-MII.(RSI03) Daleot'lssue; August 22. 2010

1. TEST RESULT CERTIFICATION

Applicant: iTech Company LLC 41758 Christv Slrcct.Frcmont CA 94538 USA

Equipment Under Test:

Trade Name:

Model Number:

19" Military LCD Monitor

iTcch

WMRM919

Date of Test: August 18, 2010

APPLICABLE STANDARDS

STANDARD TEST RESULT

Mil . STD 461 E/F No non-compliance noted

Applicable Standard Test Result

MIL STD 461 E/F

RSI03, radiated susceptibility, electric field, 2 MHz to 40 GHz. (Test frequency 200 MHz to 18 GHz / 50V/m)

No non-compliance noted

Deviation from Applicable Standard

N/A

The above equipment was tested by Compliance Certification Services Inc. for compliance with the requirements set forth in MIL STD 461 E/F. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce ihe same results due to production tolerance and measurement uncertainties.

Approved by: Reviewed by:

r r James Lee Section Manager Compliance Certification Services Inc.

I ^ <y U £JA Bruce Chen Senior Engineer Compliance Certification Services Inc.

Page 3 Re\ 00

Page 4: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

ccs Compliance Certification Services Inc. Report No: 90626003-MIL(RS103) Date oflssue: August 22, 2010

2. EUT DESCRIPTION Product 19" Military LCD Monitor

Trade Name iTcch

Model Number WMRM919

Model Discrepancy

EUT Power Rating

MB: iTech / R2A Panel LCD: 20.1 AUO/ M201UN02-V6 Power Board: Wearnes/ WDS080121 RS232 Port: Link PC /Touch

Remark: for more details, please refer to the User's manual of the EUT.

Page 4 Rev. 00

Page 5: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

Compliance Certification Sennces Inc. Report No: 90626003-MTL(RS 103) Dale of Issue: August 22, 2010

3. TEST METHODOLOGY All tests were performed in accordance with the procedure documented in MIL STD 461E/F.

4. INSTRUMENT AND CALIBRATION 4.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer's recommendations for utilizing calibration equipment, which is traceable to recognized national standards.

4.2 MEASUREMENT EQUIPMENT USED Equipment Used for Emissions Measurement

RS103 (RS Chamber)

Name of Equipment Manufacturer Model Serial Number Calibration Due

Pulse Generator Agilent 81101A DE41B01423 10/31/2009 Signal Generator (250kHz-40GHz) Agilent E8257C US42340383 07/14/2010

500 Watt 10kHz Amplifier

Amplifier Research 500A100A 300299 N C R

500 Watts 80-1000MHz Amplifier Amplifier Research 500W 1000A 320994 NCR.

250 Watts 1-2.5GHz Amplifier Amplifier Research 250T1G3M1 320245 N.C.R.

300 Watts 2.5-7.5GH.Z Amplifier Amplifier Research 300T2G8M1 320255 N.C.R.

250 Watts 7.5-18GHz Amplifier Amplifier Research 250T8G18M1 320246 N.C.R.

RF Test System Controller Amplifier Research SC1000M3 306666 N.C.R.

Power Meier Boonlon 4232A-01-02 98501 10/30/2009

Power Sensor Boonlon 5I013-4E 32864 10/30/2009

Power Sensor Boonlon 51013-1E 32862 10/30/2009

Bi-log Antenna SCHWARZBECK VULB9166 9166-1093 N.C.R

Log-Periodic Antenna Amplifier Research ATI080 306709 N.C.R.

Horn SCHWARZBECK BBHA9120D 530 N.C.R.

Field Probe(3M-18GHz) Amplifier Research FP7018 311430 07/10/2010 Dual Directional Coupler

(80-1000MHz) Amplifier Research DC6180A 320285 N.C.R.

Dual Directional Coupler (0.8-4,2GHz) Amplifier Research DC7144A 313674 N.C.R.

Dual Directional Coupler (2-8GHz) Amplifier Research DC7280A 320524 N.C.R.

Dual Directional Coupler (7.5-18GHZ) Amplifier Research DC7450M1 0320073 N.C.R.

Antenna Tower Amplifier Research TP2000 N/A N.C.R.

Probe Stand Amplifier Research PS2000 N/A N.C.R.

LISN R&S AT/A3 8 8448773 10/27/2009

Software SWI006

Page 5 Rev. 00

Page 6: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

xcs Compliance Certification Services Inc. Report No: 90626003-MTL(RS103) Dale of Issue: August 22, 2010

5. FACILITIES AND ACCREDITATIONS

5.1 FACILITIES All measurement facilities used to collect the measurement data are located at

I I No. 199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R O C

Tel: 886-2-2217-0894/Fax: 886-2-2217-1029

>3 No.ll, Wugong6th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan Tel: 886-2-2299-9720/Fax: 886-2-2299-9721

I I No.81-1, Lane 210, Bade 2nd Rd., Luchu Hsiang, Taoyuan Hsien 338, Taiwan

Tel: 886-3-324-0332 / Fax: 886-3-324-5235 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22.

Page 6 Rev. 00

Page 7: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

Compliance Certification Services Inc. Report No: 90626003-MIL(RS 103) Dale of Issue: August 22, 2010

6. SETUP OF EQUIPMENT UNDER TEST 6.1 SETUP CONFIGURATION OF EUT See test photographs attached in Appendix 1 for the actual connections between EUT and support equipment.

6.2 PHOTOGRAPHS OF EUT See test photographs attached in Appendix 2 for the EUT's internal structure.

6.3 SUPPORT EQUIPMENT No. Device

Type Brand Model Series No. FCC ID Data Cable Power Cord

1 Notebook PC DliLL PP19L G1I645 A03 E2KWM3945ABG N/A N/A

Remarks: 1. All the above equipment/cables were placed in worse case positions to maximize emission signals

during emission test. 2. Grounding was established in accordance with the manufacturer's requirements and conditions for

the intended use.

6.4 TEST SETUP The equipment under test was configured and operated in normal continuously EUT tends to maximize its emission characteristics in a typical application for immunity test. The EUT was active during the immunity test measurements.

Page 7 Rev. 00

Page 8: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

xcs Compliance Certification Services Inc. Report No: 90626003-MIL(RS 103) Dale of Issue: August 22, 2010

7. MIL STD 461E/F REQUIREMENTS 7.1 RS103, radiated susceptibility, electric, 2 MHz to 40 GHz

LIMIT The EUT shall not exhibit any malfunction, degradation of performance, or deviation from specified indications, beyond the tolerances indicated in the individual equipment or subsystem specification, when subjected to the radiated electric fields listed in Table VII and modulated as specified below. Up to 30 MHz, the requirement shall be met for vertically polarized fields. Above 30 MHz, the requirement shall be met for both horizontally and vertically polarized fields. Circular polarized fields are not acceptable.

Table VII. RS103 limits.

LIMIT LEVEL (VOLTS MEIER) jj N. PLATTORM

EREQ X

(EXTERNAL ; R SAFETY

CRITICAL)

ARCXAFT KTEKMAL

ALL SHL?S

[ABOVE EECKSl

SUBltAKC'SS .'EXTERNAL;."

SHIPS (METALLIC)

(BELOW DECKS)

SHIPS ,?JCW-METALLIC)

(BELOW DECKS; sntaaMBOM

(INTERNAL) GROUND iPACE

1 30 MHz

A. 200 200 ^|V 10 50 :• 50 20 1

30 MHz K : > > : 200 200 10 50 5 •Q 20 1

30 MHz AF :>;>: 20 - - 10 20 30 MHz

i 1 E-iz

A :oo 200 CO 10 10 10 50 20 30 MHz

i 1 E-iz

K 200 200 200 10 10 10 20 20 30 MHz

i 1 E-iz AF 200 20 - - - - 19 20 1 E iz

i LEGHz

A 200 200 200 10 10 10 50 20 1 E iz

i LEGHz

N 200 200 200 10 10 10 50 20 1 E iz

i LEGHz AF 200 SO - - - - 50 20

IE GHz

i +0GHz

A 200 200 200 10 10 10 50 20 IE GHz

i +0GHz

K 200 S5 200 10 i : : ■ ; , 50 20

IE GHz

i +0GHz AF 200 60 - 50 20

KEY A = Anny K = Navy AF = Air Forts

* ror equipmeuc Jot jred eternal to the preiiTFe fcull o:a iiibniarLne but iviihm rks stperiinierure. l^e SHIPS (METALLIC J'EELOW DECKS)

Page 8 Rev. 00

Page 9: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

Compliance Certification Sennces Inc. Report No: 90626003-MIL(RS 103) Dale of Issue: August 22, 2010

CLASSIFICATION OF FUNCTIONAL STATUS All classifications are for the total device/system functional status. Class A: all functions of a device/system perform as designed during and after exposure to

disturbance. Class B: all functions of a device/system perform as designed during exposure. However, one or

more of them can go beyond specified tolerance. All functions return automatically to within normal limits after exposure is removed

Class C: one or more functions of a device/system do not perform as designed during exposure but return automatically to normal operation after exposure is removed.

Class D: one or more functions of a device/system do not perform as designed during exposure and do not return to normal operation until exposure is removed and the device/system is reset by simple "operator/use" action.

Class E: one or more functions of a device/system do not perform as designed during and after exposure and cannot be returned to proper operation without repairing or replacing the device/system.

NOTE: The word "function" in this context refers only to the function performed by the electronic system.

Page 9 Rev. 00

Page 10: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

xcs Compliance Certification Services Inc. Report No: 90626003-MIL(RS 103) Dale of Issue: August 22, 2010

TEST CONFIGURATION

TEST SETUP BOUNDARY Electric Field

Sensor

EUT

LISN

3 m

.5 m

SZ Antenna

RF Amplifiers

Signal Source

i

i i

t t i i

Shielded Enclosure

Stimulation and Monitoring

Equipment

Electric Field Sensor Display

FIGURE RS103-1. Test equipment configuration.

Page 10 Rev. 00

Page 11: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

ccs Compliance Certification Services Inc. Report No: 90626003-MIL(RS 103) Dale of Issue: August 22, 2010

TEST SETUP BOUNDARY

LISN ■<« Electric

/ s

s v N / Field Is*\ Sensor

tr EUT EUT EUT EUT

Antenna >,/ Positions

Shielded Enclosure

RF Amplifiers

Stimulation and Monitoring

Equipment

Signal Source

Electric Field Sensor Display

FIGURE RS103-2. Multiple test antenna locations for frequency > 200 MHz.

Page I ] Rev. 00

Page 12: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

ccs Compliance Certification Services Inc. Report No: 90626003-MIL(RS 103) Dale or Issue: August 22, 2010

TEST SETUP BOUNDARY i

VJ -" O IVItJLWI Sj

LISN s s

s

*

i

i

i •

s s

s

*

i

i

i

■r EUT

9 EUT

i ■r

EUT N Electric Field Sensor

EUT i

i Posrtions

i

i

D N "

i

i

i

\ /+ lA /v D N "

i i

N Antenna Positions Shielded Enclosure

i i

RF Amplifiers

Stimulation and Monitoring

Equipment

RF Amplifiers

Stimulation and Monitoring

Equipment

Signal Electric Field Sou rce Sensor Display

FIGURE RS103-3. Multiple test antenna locations for N positions, D > 3 meters.

Page 12 Rev. 00

Page 13: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

xcs Compliance Certification Services Inc. Report No: 90626003-MIL(RS 103) Dale of Issue: August 22, 2010

Signal Source

RF Amplifiers

TEST SETUP BOUNDARY

Path for Measurement

Directional Coupler

Power Meter

Data Recorder

Receive Antenna

Signal Generator

Path for Check System

Transmit Antenna

Shielded Enclosure

Attenuator

Measurement Receiver

Data Recorder

FIGURE RS103-4. Receive antenna procedure (1 to 40 GHz).

TESTPROCEDURE The magnetic emission of EUT representative of its type shall be tested by the method(s) according to MIL STD 461E/F.

Page 13 Rev. 00

Page 14: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

Compliance Certification Sennces Inc. Report No: 90626003-MIL(RS 103) Dale of Issue: August 22, 2010

TEST RESULTS No non-compliance noted Test Data

Test Frequency

(MHz)

Field Strength

(V/m) Radiate Signal Polarity

Test Result

Remark

200-1000 50 PM lkHz/50% H A Normal function

200-1000 50 PM lkHz/50% V A Normal function

1000-2500 50 PM 1 kHz/50% H A Normal function

1000-2500 50 PM lkHz/50% V A Normal function

2500-7500 50 PM 1 kHz/50% H A Normal function

2500-7500 50 PM lkHz/50% V A Normal function

7500-18000 50 PM lkHz/50% H A Normal function

7500-18000 50 PM lkHz/50% V A Normal function

Page 14 Rev. 00

Page 15: MILSTD461E/F TEST REPORT For 19 Military LCD Monitor Model

xcs Compliance Certification Services Inc. Report No: 90626003-MIL(RS 103) Dale or Issue: August 22, 2010

8. APPENDIX I PHOTOGRAPHS OF TEST SETUP

RS103, radiated susceptibility, electric, 2 MHz to 40 GHz (Test frequency 200 MHz to 18 GHz)

Page 15 Rev. 00