SUPPLY DIFFUSER CONNECTION - SOLID DUCT WITH FLEXIBLE CONNECTION
AutoCAD SHX Text
N T S
AutoCAD SHX Text
3
AutoCAD SHX Text
M4.0
AutoCAD SHX Text
5
AutoCAD SHX Text
SQUARE DUCTWORK FITTINGS
AutoCAD SHX Text
M4.0
AutoCAD SHX Text
4
AutoCAD SHX Text
ROUND DUCTWORK FITTINGS
AutoCAD SHX Text
M4.0
AutoCAD SHX Text
6
AutoCAD SHX Text
DOMESTIC HOT WATER HEATER PIPING SCHEMATIC - SIMPLEX TANKS
AutoCAD SHX Text
M4.0
AutoCAD SHX Text
7
AutoCAD SHX Text
NFPA 96 KITCHEN EXHAUST DETAIL
AutoCAD SHX Text
M4.0
AutoCAD SHX Text
3"
AutoCAD SHX Text
76" RECOMMENDED
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
LTD
AutoCAD SHX Text
F A X : 2 5 0 3 5 2 - 6 5 4 2
AutoCAD SHX Text
T E L : 2 5 0 3 5 2 - 5 3 7 1
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
FAIRBANK
AutoCAD SHX Text
N E L S O N , B C V I L 4 E 5
AutoCAD SHX Text
4 0 4 V E R N O N S T R E E T
AutoCAD SHX Text
PROJECT STATUS
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
DRAWING DATE:
AutoCAD SHX Text
PROJECT No.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
EOR:
AutoCAD SHX Text
COMMUNITY CENTRE
AutoCAD SHX Text
ISSUED FOR COORDINATION
AutoCAD SHX Text
AUG 03 17
AutoCAD SHX Text
692 7th AVE.
AutoCAD SHX Text
16659.001
AutoCAD SHX Text
AUG 17
AutoCAD SHX Text
JB
AutoCAD SHX Text
MO
AutoCAD SHX Text
AS
AutoCAD SHX Text
MIDWAY, B.C.
AutoCAD SHX Text
ISSUED FOR REVIEW
AutoCAD SHX Text
AUG 22 17
AutoCAD SHX Text
M4.0
AutoCAD SHX Text
1/4"=1'-0"
AutoCAD SHX Text
DETAILS
1 GRADE OR PAVING.
2 CAST IRON CLEANOUT WITH COVERFOR DUTY REQUIRED.
3 150 THICK CONCRETE PAD.
4 SEWER PIPE.
5 45° BEND.
6 SEWER MAIN.
7 FROM BUILDING DRAIN.
DRAWINGS NOTES APPLY WHERE INDICATED:
76
5
4
1 2 3
DRAWING NOTES APPLY WHERE INDICATED:
1 HINGED ACCESS DOOR.
2 TOP RAIL SUPPORT BOLTED TO COVER FRAME.
3 LIFTING CHAIN.
4 JUNCTION BOX.
5 3" INLET PIPE.
6
7
GATE VALVE.
8
SWING CHECK VALVE.
9
10
DISCHARGE PIPING.
VERTICAL PIPE GUIDE RAILS AS REQUIRED.
11
SUBMERSIBLE NON-CLOG PUMP.
12
13
BOTTOM OF BASIN MUST HAVE SMOOTH
15
14
LIFT-OUT ASSEMBLY.
TROWELED SURFACE FOR MOUNTING OF THE SUPPORT CASTING.
4" (100mm)
ALARM LEVEL.
TURN ON ONE PUMP.
TURN OFF ONE PUMP.
2 1/2" VENT.
8"(200mm)
8"(200mm)
48"(1200mm)
4" (100mm)
4" (100mm)
16
17
INLET LEVEL.
13
14
15
16
12
1110
9
8
7 7
6 6
8
5 5
4
33
2
1 1
17
STORM COLLAR (TYP.)
CONE FLASHINGBELOW STORMCOLLAR (TYP.)
STORM COLLAR
ROOF JACK
TOP VIEW
SIDE VIEW
VENT
CAP FLASHING OVERTOP OF CONE FLASHING
VENT
COMBINATION AIR INLET
COMBINATION AIR INLET
DRAWING NOTES APPLY WHERE INDICATED:
1 HANGER ROD.
2 LOCK NUT.
3 SUPPORT NUT.
4 HEAVY DUTY CLEVIS HANGER.
5 VAPOUR BARRIER INSULATION.
6 INSULATION WHERE SPECIFIED BUTT AGAINST PIPE HANGER.
7 16 GA ZINC COATED SHEET METAL PIPE COVERING PROTECTIONSADDLE. LENGTH SHALL BE AT LEAST TWICE THE OUTSIDEDIAMETER OF THE INSULATION BUT NOT LESS THAN 300mm LONG.
NOTE:COPPER PIPING SHALL BE SUPPORTED BYCOPPER PLATED HANGERS. SEE SPEC.
2 1/8" SLOTS CUT IN TO BOTTOM OF RADON VENT PIPE. SLOTS TO BECUT THE FULL LENGTH OF ALL PIPE INSTALLED BELOW GRADE.
DRAWING NOTES APPLY WHERE INDICATED:
1 DISCHARGE OF STACK TO BE 25' (7.6M) AWAY FROM ANY AIR INTAKE.
2
RADON EXHAUST FAN RF-1. 3
4
5
1
2
3
5
6
REFER TO ARCHITECTURAL FOR ALL ROOFPENETRATION, MEMBRANE AND FLASHING DETAILS
CONNECT FAN TO PIPE WITH RUNNER PIPE CONNECTORS.
6
2
4
6" (150mm) SYSTEM 15 PVC PIPE. PROVIDE WARNING LABELINDICATING "WARNING, STACK MAY CONTAIN HIGH LEVELSOF RADON. DO NOT PLACE AIR INTAKE WITHIN 25 FEET."
24"
(600
mm
)18
"(4
50m
m)
SUPPORT BY MECHANICAL INCLUDING EDPM BOOT, SECURED WITHDRAW BAND AND POLYURETHANE SEALANT WHERE REQUIRED.
GOOSENECK C/W BIRDSCREEN7
7
210-1715 Dickson Ave. Kelowna, BC V1Y 9G6250.762.9993 www.falcon.ca
AutoCAD SHX Text
1
AutoCAD SHX Text
CLEANOUT TO GRADE
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
2
AutoCAD SHX Text
SUBMERSIBLE SIMPLEX PUMP DETAIL
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
3
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
GAS FIRED EQUIPMENT COMBINATION AIR/VENT TERMINATION ON ROOF DETAIL
AutoCAD SHX Text
4
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
5
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
6
AutoCAD SHX Text
PIPE HANGER DETAIL
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
SHEET METAL HOUSING
AutoCAD SHX Text
DUCT SUSPENSION - EXPOSED
AutoCAD SHX Text
WM
AutoCAD SHX Text
PRV
AutoCAD SHX Text
WATER ENTRY
AutoCAD SHX Text
N.C.
AutoCAD SHX Text
7
AutoCAD SHX Text
SLOTTED RADON VENT PIPE
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
8
AutoCAD SHX Text
RADON EXHAUST FAN MOUNTING ARRANGEMENT
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
LTD
AutoCAD SHX Text
F A X : 2 5 0 3 5 2 - 6 5 4 2
AutoCAD SHX Text
T E L : 2 5 0 3 5 2 - 5 3 7 1
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
FAIRBANK
AutoCAD SHX Text
N E L S O N , B C V I L 4 E 5
AutoCAD SHX Text
4 0 4 V E R N O N S T R E E T
AutoCAD SHX Text
PROJECT STATUS
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
DRAWING DATE:
AutoCAD SHX Text
PROJECT No.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
EOR:
AutoCAD SHX Text
COMMUNITY CENTRE
AutoCAD SHX Text
ISSUED FOR COORDINATION
AutoCAD SHX Text
AUG 03 17
AutoCAD SHX Text
692 7th AVE.
AutoCAD SHX Text
16659.001
AutoCAD SHX Text
AUG 17
AutoCAD SHX Text
JB
AutoCAD SHX Text
MO
AutoCAD SHX Text
AS
AutoCAD SHX Text
MIDWAY, B.C.
AutoCAD SHX Text
ISSUED FOR REVIEW
AutoCAD SHX Text
AUG 22 17
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
1/4"=1'-0"
AutoCAD SHX Text
DETAILS
7
7
7 7
777
7
7
7
7 7 7 7
7
7 7 7
7
DRAWING NOTES APPLY WHERE INDICATED:
1. BEAM OVER.
2. BULKHEAD OR FURRING.
3. CAP FOR FUTURE.
4. EXISTING TO REMAIN IN SERVICE.
5. EXISTING TO BE ABANDONED. REMOVE AS REQUIRED TOSUIT NEW CONSTRUCTION.
6. EXISTING TO BE RELOCATED.
7. EXISTING TO BE REMOVED.
8. CAP EXISTING IN THIS APPROXIMATE LOCATION.
9. CONNECT TO EXISTING IN THIS APPROXIMATE LOCATION.
10. PVC SYSTEM 15 RADON EXHAUST PIPE. CONNECT TO PIPEPROVIDED BY THE GENERAL TRADE AND TERMINATE WITHGOOSENECK ON THE ROOF.
11. FOR CONTINUATION, SEE SITE SERVICES.
12. ROOF ACCESS.
13. CEILING ACCESS.
14. BUILDING GAS SERVICE AND METER.
15. CLEAN-OUT AT GRADE. REFER TO DETAIL.
16. RUN PIPE AT 2% SLOPE WHERE INDICATED BY DRAWINGNOTE.
17. IRRIGATION WATER SERVICE.
18. ROUGH-IN HOT, COLD, WASTE AND VENT PIPING IN WALLFOR FUTURE FIXTURE.
19. PROVIDE 1-1/2" TRAPPED WASTE AND 1/2" VALVED HOTWATER SUPPLY TO SUIT DISHWASHER.
20. PROVIDE NEW CONDENSATE ACID NEUTRALIZER. RUN 1-1/4"DRAIN LINE TO FLOOR DRAIN. 2 BOILER CONNECTIONS PERACID NEUTRALIZER.
21. GAS PRV (FROM 2 psi TO 7" wc) C/W ISOLATION VALVE.PROVIDE PRV VENT AS PER GAS CODE.
22. GAS SUPPLY UP TO ROOF MOUNTED EQUIPMENT. REFER TODETAIL.
23. EXTEND DOMESTIC WATER SERVICE TO THIS POINT ANDDISTRIBUTE HOT AND COLD SUPPLY TO EACH FIXTURE INTHE ROOM.
24. 3" BUILDING VENT.
25. EXACT LOCATION OF DOMESTIC HOT AND COLD WATER TOBE DETERMINED IN FIELD.
26. SANITARY AND DOMESTIC WATER SERVICES INSTALLEDTIGHT TOGETHER.
27. SYSTEM 15 PVC.
28. DISCHARGE FORCE MAIN INTO TOP OF GRAVITY MAIN.
29. ISLAND VENT.
30. NEW 2 PSI FORTIS NATURAL GAS METER. COORDINATE WITHFORTIS FOR REPLACEMENT.
31. SLAB ELEVATION 100' - 0"
32. RUN 1" CONDENSATE DRAIN LINE TO FUNNEL FLOOR DRAIN.
33. SOLENOID VALVE TO CONNECT TO KITCHEN FIRESUPPRESSION SYSTEM.
210-1715 Dickson Ave. Kelowna, BC V1Y 9G6250.762.9993 www.falcon.ca
4' 3' 2' 1'
12'8'4'0
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
Furnace Room
AutoCAD SHX Text
Storage
AutoCAD SHX Text
HALL
AutoCAD SHX Text
HWT
AutoCAD SHX Text
HWT
AutoCAD SHX Text
WPT
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
ACCESS POINT IN PARKING LOT
AutoCAD SHX Text
SANITARY SUMP PUMP
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
LV
AutoCAD SHX Text
UR
AutoCAD SHX Text
WC
AutoCAD SHX Text
UR
AutoCAD SHX Text
WC
AutoCAD SHX Text
WC
AutoCAD SHX Text
LV
AutoCAD SHX Text
LV
AutoCAD SHX Text
SK
AutoCAD SHX Text
SK
AutoCAD SHX Text
SK
AutoCAD SHX Text
SK
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
LTD
AutoCAD SHX Text
F A X : 2 5 0 3 5 2 - 6 5 4 2
AutoCAD SHX Text
T E L : 2 5 0 3 5 2 - 5 3 7 1
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
FAIRBANK
AutoCAD SHX Text
N E L S O N , B C V I L 4 E 5
AutoCAD SHX Text
4 0 4 V E R N O N S T R E E T
AutoCAD SHX Text
PROJECT STATUS
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
DRAWING DATE:
AutoCAD SHX Text
PROJECT No.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
EOR:
AutoCAD SHX Text
COMMUNITY CENTRE
AutoCAD SHX Text
ISSUED FOR COORDINATION
AutoCAD SHX Text
AUG 03 17
AutoCAD SHX Text
692 7th AVE.
AutoCAD SHX Text
16659.001
AutoCAD SHX Text
AUG 17
AutoCAD SHX Text
JB
AutoCAD SHX Text
MO
AutoCAD SHX Text
AS
AutoCAD SHX Text
MIDWAY, B.C.
AutoCAD SHX Text
ISSUED FOR REVIEW
AutoCAD SHX Text
AUG 22 17
AutoCAD SHX Text
M5.0
AutoCAD SHX Text
1/4"=1'-0"
AutoCAD SHX Text
BASEMENT FLOOR PLUMBING - DEMOLITION
7
7
7
7
DRAWING NOTES APPLY WHERE INDICATED:
1. BEAM OVER.
2. BULKHEAD OR FURRING.
3. CAP FOR FUTURE.
4. EXISTING TO REMAIN IN SERVICE.
5. EXISTING TO BE ABANDONED. REMOVE AS REQUIRED TOSUIT NEW CONSTRUCTION.
6. EXISTING TO BE RELOCATED.
7. EXISTING TO BE REMOVED.
8. CAP EXISTING IN THIS APPROXIMATE LOCATION.
9. CONNECT TO EXISTING IN THIS APPROXIMATE LOCATION.
10. PVC SYSTEM 15 RADON EXHAUST PIPE. CONNECT TO PIPEPROVIDED BY THE GENERAL TRADE AND TERMINATE WITHGOOSENECK ON THE ROOF.
11. FOR CONTINUATION, SEE SITE SERVICES.
12. ROOF ACCESS.
13. CEILING ACCESS.
14. BUILDING GAS SERVICE AND METER.
15. CLEAN-OUT AT GRADE. REFER TO DETAIL.
16. RUN PIPE AT 2% SLOPE WHERE INDICATED BY DRAWINGNOTE.
17. IRRIGATION WATER SERVICE.
18. ROUGH-IN HOT, COLD, WASTE AND VENT PIPING IN WALLFOR FUTURE FIXTURE.
19. PROVIDE 1-1/2" TRAPPED WASTE AND 1/2" VALVED HOTWATER SUPPLY TO SUIT DISHWASHER.
20. PROVIDE NEW CONDENSATE ACID NEUTRALIZER. RUN 1-1/4"DRAIN LINE TO FLOOR DRAIN. 2 BOILER CONNECTIONS PERACID NEUTRALIZER.
21. GAS PRV (FROM 2 psi TO 7" wc) C/W ISOLATION VALVE.PROVIDE PRV VENT AS PER GAS CODE.
22. GAS SUPPLY UP TO ROOF MOUNTED EQUIPMENT. REFER TODETAIL.
23. EXTEND DOMESTIC WATER SERVICE TO THIS POINT ANDDISTRIBUTE HOT AND COLD SUPPLY TO EACH FIXTURE INTHE ROOM.
24. 3" BUILDING VENT.
25. EXACT LOCATION OF DOMESTIC HOT AND COLD WATER TOBE DETERMINED IN FIELD.
26. SANITARY AND DOMESTIC WATER SERVICES INSTALLEDTIGHT TOGETHER.
27. SYSTEM 15 PVC.
28. DISCHARGE FORCE MAIN INTO TOP OF GRAVITY MAIN.
29. ISLAND VENT.
30. NEW 2 PSI FORTIS NATURAL GAS METER. COORDINATE WITHFORTIS FOR REPLACEMENT.
31. SLAB ELEVATION 100' - 0"
32. RUN 1" CONDENSATE DRAIN LINE TO FUNNEL FLOOR DRAIN.
33. SOLENOID VALVE TO CONNECT TO KITCHEN FIRESUPPRESSION SYSTEM.
210-1715 Dickson Ave. Kelowna, BC V1Y 9G6250.762.9993 www.falcon.ca
4' 3' 2' 1'
12'8'4'0
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
Coats
AutoCAD SHX Text
Pass-thru
AutoCAD SHX Text
Freezer
AutoCAD SHX Text
Refrige
AutoCAD SHX Text
Loading Dock
AutoCAD SHX Text
Overhang
AutoCAD SHX Text
Overhang
AutoCAD SHX Text
Overhang
AutoCAD SHX Text
Sidewalk
AutoCAD SHX Text
Duct Shaft
AutoCAD SHX Text
DW
AutoCAD SHX Text
Site Fabricated Walk In Cooler
AutoCAD SHX Text
10' Pass-thru
AutoCAD SHX Text
Roll-up Shutter
AutoCAD SHX Text
Sidewalk
AutoCAD SHX Text
Duct Shaft
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
Lobby
AutoCAD SHX Text
Hall
AutoCAD SHX Text
Stage
AutoCAD SHX Text
EXISTING 3/4" HOSE BIBB
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
LTD
AutoCAD SHX Text
F A X : 2 5 0 3 5 2 - 6 5 4 2
AutoCAD SHX Text
T E L : 2 5 0 3 5 2 - 5 3 7 1
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
FAIRBANK
AutoCAD SHX Text
N E L S O N , B C V I L 4 E 5
AutoCAD SHX Text
4 0 4 V E R N O N S T R E E T
AutoCAD SHX Text
PROJECT STATUS
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
DRAWING DATE:
AutoCAD SHX Text
PROJECT No.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
EOR:
AutoCAD SHX Text
COMMUNITY CENTRE
AutoCAD SHX Text
ISSUED FOR COORDINATION
AutoCAD SHX Text
AUG 03 17
AutoCAD SHX Text
692 7th AVE.
AutoCAD SHX Text
16659.001
AutoCAD SHX Text
AUG 17
AutoCAD SHX Text
JB
AutoCAD SHX Text
MO
AutoCAD SHX Text
AS
AutoCAD SHX Text
MIDWAY, B.C.
AutoCAD SHX Text
ISSUED FOR REVIEW
AutoCAD SHX Text
AUG 22 17
AutoCAD SHX Text
M5.1
AutoCAD SHX Text
1/4"=1'-0"
AutoCAD SHX Text
MAIN FLOOR PLUMBING - DEMOLITION
DRAWING NOTES APPLY WHERE INDICATED:
1. REFER TO DETAIL FOR REQUIRED VALVING ARRANGEMENT.
2. BULKHEAD OR FURRING.
3. CAP FOR FUTURE.
4. EXISTING TO REMAIN IN SERVICE.
5. EXISTING TO BE ABANDONED. REMOVE AS REQUIRED TOSUIT NEW CONSTRUCTION.
6. EXISTING TO BE RELOCATED.
7. EXISTING TO BE REMOVED.
8. CAP EXISTING IN THIS APPROXIMATE LOCATION.
9. CONNECT TO EXISTING IN THIS APPROXIMATE LOCATION.
10. PVC SYSTEM 15 RADON EXHAUST PIPE. CONNECT TO PIPEPROVIDED BY THE GENERAL TRADE AND TERMINATE WITHGOOSENECK ON THE ROOF.
11. FOR CONTINUATION, SEE SITE SERVICES.
12. ROOF ACCESS.
13. CEILING ACCESS.
14. DUCT IN JOIST SPACE.
15. DUCT TIGHT TO UNDERSIDE OF STRUCTURE IN CEILINGSPACE.
16. ALL DUCT RUNOUTS TO DIFFUSERS ARE TO BE DIFFUSERNECK SIZE UNLESS OTHERWISE INDICATED.
17. PROVIDE MANUAL VOLUME DAMPER. PROVIDE ACCESS ASREQUIRED.
18. MOUNT GRILLE 8" ABOVE FLOOR LEVEL.
19. DUCT UP TO GOOSENECK ON ROOF.
20. MOUNT AT HIGH LEVEL.
21. PROVIDE BACKDRAFT DAMPER AT BUILDING ENVELOPEPENETRATION. REFER TO SPEC.
22. PROVIDE TRANSITION FOR DUCT UNDER BEAM.
23. ELECTRIC HEAT.
24. GRAVITY BACKDRAFT DAMPER.
25. PROVIDE FIRE DAMPER AT FIRE SEPARATION.
26. RE-BALANCE EXISTING GRILLE OR DIFFUSER TO NEWSPECIFIED AIR FLOW.
27. NEW SEWAGE LIFE STATION, SEE PLUMBING FOR DETAILS.
28. COMBUSTION AIR AND VENTS TO BE DUCTED TO ROOF.DUCT ROUTING SHOWN ON LOW LEVEL MECHANICAL ROOMPLAN.
29. UNDERCUT DOOR.
30. NFPA 96 KITCHEN EXHAUST HOOD.
31. FIRE RATED FURRING.
32. ACCESS PANEL.
33. CONFIRM JOIST SPACING TO DETERMINE RELIEF GRILLE CONFIGURATION/ SIZE TO NOT CONFLICT WITH STRUCTURE.
34. INSTALL ACOUSTIC INSULATION FOR FIRST 5FT AFTER WALLPENETRATION.
35. REQUIRES 42"x42" HOUSEKEEPING PAD. REFER TOSTRUCTURAL FOR DETAILS.
210-1715 Dickson Ave. Kelowna, BC V1Y 9G6250.762.9993 www.falcon.ca
4' 3' 2' 1'
12'8'4'0
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
HWT
AutoCAD SHX Text
HWT
AutoCAD SHX Text
WPT
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
Furnace Room
AutoCAD SHX Text
Storage
AutoCAD SHX Text
HALL
AutoCAD SHX Text
FAN
AutoCAD SHX Text
FAN
AutoCAD SHX Text
FAN
AutoCAD SHX Text
(TYP. 12)
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
LTD
AutoCAD SHX Text
F A X : 2 5 0 3 5 2 - 6 5 4 2
AutoCAD SHX Text
T E L : 2 5 0 3 5 2 - 5 3 7 1
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text
FAIRBANK
AutoCAD SHX Text
N E L S O N , B C V I L 4 E 5
AutoCAD SHX Text
4 0 4 V E R N O N S T R E E T
AutoCAD SHX Text
PROJECT STATUS
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
DRAWING DATE:
AutoCAD SHX Text
PROJECT No.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
EOR:
AutoCAD SHX Text
COMMUNITY CENTRE
AutoCAD SHX Text
ISSUED FOR COORDINATION
AutoCAD SHX Text
AUG 03 17
AutoCAD SHX Text
692 7th AVE.
AutoCAD SHX Text
16659.001
AutoCAD SHX Text
AUG 17
AutoCAD SHX Text
JB
AutoCAD SHX Text
MO
AutoCAD SHX Text
AS
AutoCAD SHX Text
MIDWAY, B.C.
AutoCAD SHX Text
ISSUED FOR REVIEW
AutoCAD SHX Text
AUG 22 17
AutoCAD SHX Text
M5.2
AutoCAD SHX Text
1/4"=1'-0"
AutoCAD SHX Text
BASEMENT FLOOR HVAC - DEMOLITION
DRAWING NOTES APPLY WHERE INDICATED:
1. REFER TO DETAIL FOR REQUIRED VALVING ARRANGEMENT.
2. BULKHEAD OR FURRING.
3. CAP FOR FUTURE.
4. EXISTING TO REMAIN IN SERVICE.
5. EXISTING TO BE ABANDONED. REMOVE AS REQUIRED TOSUIT NEW CONSTRUCTION.
6. EXISTING TO BE RELOCATED.
7. EXISTING TO BE REMOVED.
8. CAP EXISTING IN THIS APPROXIMATE LOCATION.
9. CONNECT TO EXISTING IN THIS APPROXIMATE LOCATION.
10. PVC SYSTEM 15 RADON EXHAUST PIPE. CONNECT TO PIPEPROVIDED BY THE GENERAL TRADE AND TERMINATE WITHGOOSENECK ON THE ROOF.
11. FOR CONTINUATION, SEE SITE SERVICES.
12. ROOF ACCESS.
13. CEILING ACCESS.
14. DUCT IN JOIST SPACE.
15. DUCT TIGHT TO UNDERSIDE OF STRUCTURE IN CEILINGSPACE.
16. ALL DUCT RUNOUTS TO DIFFUSERS ARE TO BE DIFFUSERNECK SIZE UNLESS OTHERWISE INDICATED.
17. PROVIDE MANUAL VOLUME DAMPER. PROVIDE ACCESS ASREQUIRED.
18. MOUNT GRILLE 8" ABOVE FLOOR LEVEL.
19. DUCT UP TO GOOSENECK ON ROOF.
20. MOUNT AT HIGH LEVEL.
21. PROVIDE BACKDRAFT DAMPER AT BUILDING ENVELOPEPENETRATION. REFER TO SPEC.
22. PROVIDE TRANSITION FOR DUCT UNDER BEAM.
23. ELECTRIC HEAT.
24. GRAVITY BACKDRAFT DAMPER.
25. PROVIDE FIRE DAMPER AT FIRE SEPARATION.
26. RE-BALANCE EXISTING GRILLE OR DIFFUSER TO NEWSPECIFIED AIR FLOW.
27. NEW SEWAGE LIFE STATION, SEE PLUMBING FOR DETAILS.
28. COMBUSTION AIR AND VENTS TO BE DUCTED TO ROOF.DUCT ROUTING SHOWN ON LOW LEVEL MECHANICAL ROOMPLAN.
29. UNDERCUT DOOR.
30. NFPA 96 KITCHEN EXHAUST HOOD.
31. FIRE RATED FURRING.
32. ACCESS PANEL.
33. CONFIRM JOIST SPACING TO DETERMINE RELIEF GRILLE CONFIGURATION/ SIZE TO NOT CONFLICT WITH STRUCTURE.
34. INSTALL ACOUSTIC INSULATION FOR FIRST 5FT AFTER WALLPENETRATION.
35. REQUIRES 42"x42" HOUSEKEEPING PAD. REFER TO
210-1715 Dickson Ave. Kelowna, BC V1Y 9G6250.762.9993 www.falcon.ca