Security System SensorIntelligent Passive Infrared Sensor 1Passive Infrared Sensor 1 ~ 5Anti-masking base unit 5Passive Infrared Sensor (for outdoor use) 6 ~ 7Flame Sensor 8Combination Sensor 9Microwave Sensor 9Miniature Photoelectric Beam Sensor 10Photoelectric Beam Sensor 11 ~ 14Explosion-proof Photoelectric Beam Sensor 14Solar Powered Beam Sensor System 15Shutter Sensor 17Glass Sensor 18Magnetic Switch 19
Access Door Sensor SystemAuto Door Sensor (Passive Infrared) 24Auto Door Sensor (Photoelectric Beam) 25 ~ 26
Multi-channel Control Panel 20
Control Panel
Sensor Speaker 21Sensor Switch 22
Sensor Speaker & Sensor Switch
Homey Goods 23Voice Speaker 23Key Post 23
Homey Goods & Voice Speaker & Presence Timer Sensor
Weight
Detection System
Detection System
Alarm Output
Supply VoltagePower Consumption
Features
Mounting Position
Optional
External DimensionsWeight
Ambient Temperature
1
Passive Infrared Sensor
Intelligent Passive Infrared Sensor
PA-IN-5012FWide angle protection(Coverage: 12m)
¡Anti-blindingThis unique circuitry prevents the sensor frombeing sabotaged by spray paint, paper orattachment of other materials in an attempt todeliberately “blind” the unit.
¡Self-checkingThe sensor monitors every 3.5 hours for anyinternal failure. If the unit detects a malfunctionof the circuitry, it will issue a trouble indication.
¡Trouble buzzerAudible indication of trouble on the antiblindingor self-checking functions.
¡Quad MAC circuit (patent registered) MAC circuit + two separate dual elementsensors allow rejection of common false alarmproblems such as small animals, airturbulence (heating / air conditioning) andexternal lights.
QuadDry contact (Semi-conductor) output:N/O or N/CReset time: approx. 2sec.24V (AC/DC) 0.25A Max10.5V to 30V DC (non-polarity)60mATrouble Output• Self-checking• Anti-blindingAlarm Memory!15˚C to +55˚C
Flush mount attachment, Wallmount attachment, Level checker
Ceiling, wall (indoor)
144mm dia " 86.5mm330g
PA-IN-5030FVertical curtain protection(Coverage: 30m)
SECURITY <SENSOR>
U.S. PATENT REGISTRATED : 1 / INTERNATIONAL PATENT PENDING: 2 • PATENT PENDING : 2 • UTILITY MODEL PENDING : 6
[ PATENT PENDING : 2 • UTILITY MODEL PENDING : 6 • DESIGN PENDING : 1 ]
[ ]
™E : Available in English version
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Ambient Temperature
Dry contact (semi-conductor) relayoutput N/O or N/C selectableReset time: 2sec.24V (AC/DC) 0.25A Max
10.5V to 28V DC (non-polarity)
25mA
Pulse countLED control
!15˚C to +55˚C
Ceiling / wall mount attachment
Ceiling, wall (indoor)
120mm dia " 55mm
135g
™E PA-5312EWide angle protection(Coverage: 12m)
™E PA-5325EVertical curtain protection(Coverage: 25m)
¡Slight motion detection.
84°
3m
0 12m5 10
Top viewSide view
0 5 10 15 20 25m
3m
Top view
Side view
Alarm Output
Supply VoltagePower Consumption
Features
Mounting Position
Optional
External DimensionsWeight
Ambient Temperature
QuadDry contact relay output: N/O or N/CselectableReset time: approx. 2sec.30V (AC/DC) 0.25A Max9.5V to 30V DC (non-polarity)25mAFuzzy LogicTrouble Output• Malfunction of equipment• Low voltage• Mis-replacementIndication of Malfunction• Self-check up of alarm contact output!10˚C to +55˚C
Flush mount attachment, Levelchecker
Ceiling, wall (indoor)
147.3mm dia " 59mm250g
™E PA-6612E"TWIN MIRROR" PIRWide angle protection(Coverage: 12m)
¡Drastically reduced false alarm to be causedby small animals, by incorporating new twinoptical system.
Detection System Twin " 2
0 5 12m10
2.5m
Top view
Side view
84°
0 5 10 15 20 25 30m
2.3m
Side view
Top view
0 4 8 12m
84°
2.3m
Top view Side view
2
Passive Infrared Sensor
™E PA-6812EWide angle protection(Coverage: 12m)
™E PA-6820EVertical curtain protection(Coverage:20m)
™E PA-6805ESpot protection(Coverage:H4.9m " 4m dia)
™E PA-6810E360˚ Round protection(Coverage: H4.9m " 15.2m dia)
™E PA-7012EWide angle protection(Coverage: 12m)
™E PA-7030EVertical curtain protection(Coverage: 30m)
84˚
2.6m
0' 6m
53˚
8˚
12m
30˚ Variable range
(5˚~35˚)
Side viewTop view
2.6m
20m15.2m9m
Side view
Top view
4.0m4.9m
45˚67.5˚
Side viewTop view
Side viewTop view
30˚
15.2m
4.9m
0 6 12m
80°
3m
Side viewTop view
0
3m
10 20 30m
Side view
Top view
SECURITY <SENSOR>
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Twin
Dry contact (Semi-conductor)output: N/C or N/O selectableReset time: approx. 2sec.24V (AC/DC) 0.25A Max
10.5 to 30V DC (non-polarity)
25mA: N/C
Alarm LED controlPulse count (PA-6812E only)
!15˚C to +55˚C
Ceiling / wall mount attachment
Ceiling, wall (indoor)
120mm dia " 47mm
110g
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Twin
Dry contact (Semi-conductor)output: N/C or N/O selectableReset time: approx. 2sec.24V (AC/DC) 0.25A Max
10.5 to 30V DC (non-polarity)
25mA: N/C
Alarm LED controlPulse count
!15˚C to +55˚C
Ceiling / wall mount attachment
Ceiling, wall (indoor)
120mm dia " 47mm
110g
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Quad
Dry contact relay output: 1cReset time: approx. 2sec.30V (AC/DC) 0.1A Max
9 to 18V DC (non-polarity)
15mA
Alarm memory
!10˚C to +55˚C
Flush mount attachment
Ceiling, wall (indoor)
144mm dia " 92mm
330g
INTERNATIONAL PATENT REGISTRATED : 2 • PATENT REGISTRATED : 1 • UTILITY MODELREGISTRATED : 3 • DESIGN REGISTRATED : 2 / PATENT PENDING : 6 • UTILITY MODELPENDING : 10 • DESIGN PENDING :12
[ ]
™E : Available in English version
PA-8410EWide angle protection(Coverage: 10m)
PA-8420EWide angle protection(Coverage:20m)
¡Protection area especially designed to protect fromhigh mounting positions
0
0
0
33' (10m)
33' (10m)
33' (10m)
33' (10m)
Installation height 26'(8m) Max. detection distance (Area Setting : F)
Top view
0
Side view 26' (8m)
0
7.4'(2.3m)Top view
Side view 26' (8m)
66'(20m)33'(10m)0
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Passive infraredDry contact (semi-conductor) output:N.C./N.O.24V (AC/DC) 0.25A (resistive load)9 to 30V DC (non-polarity)
30mA• Trouble alarm • Low supply voltage alarm• Tamper signal • LED control• Area control • Alarm LED (ON/OFF)• Sensitivity adjustable for 60/80/100/120%• Pulse count selectable for 1/2/3/4
(PA8410E only)
!20˚C to +50˚C
Water-proof grommet, Tapping screw
Indoor or outdoor ceiling
184.5mm dia. " 136mm
950g
3
Passive Infrared Sensor
™E PA-7100E360˚ Round protection(Coverage: 100m2)
PA-6412PI (PET IMMUNE)Wide angle protection(Coverage: 12m)
PA-370Wide angle / Vertical curtain protection(lens replacement)(Coverage: H5m " W6.7m)
3m
4.2m
Front view Lens W Side view
3m
4.2m 1.8m
Front view Lens M Side view
SECURITY <SENSOR>
Detection System
Detection System
Supply VoltagePower Consumption
Ambient TemperatureMounting PositionOptionalExternal DimensionsWeight
Features
Alarm Output
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Two quad
Twin
10 to 18VDC (non-polarity)25mA
!15˚C to +55˚CIndoor ceilingCeiling / wall mount attachment147mm dia " 60mm160g
Pulse countLED disable switchLow voltage alarm
Dry contact (Semi-conductor) output:N/C or N/O selectableReset time: approx. 2sec.24V (AC/DC) 0.25A Max
Dry contact relay output: 1cReset time: approx. 2sec.30V (AC/DC) 0.1A Max
9 to 18V DC (non-polarity)
15mA
Manual memory
!10˚C to +55˚C
Flush mount attachment
Ceiling (indoor)
144mm dia " 92mm
330gDetection System
Alarm Output
Supply VoltagePower Consumption
Features
Mounting Position
Optional
External DimensionsWeight
Ambient Temperature
TwinDry contact (semi-conductor)relay outputN/O or N/C selectableReset time: 2sec.24V (AC/DC) 0.25A Max10 to 18V DC (non-polarity)25mAPulse countLED disable switchLow voltage alarmAuto reset memory!15˚C to +55˚C
Ceiling / wall mount attachment,Line protection lens
Ceiling, wall (indoor)
120mm dia " 45mm120g
INTERNATIONAL PATENT REGISTRATED : 2 • PATENT REGISTRATED : 1 • UTILITY MODELREGISTRATED : 3 • DESIGN REGISTRATED : 2 / PATENT PENDING : 6 • UTILITY MODELPENDING : 10 • DESIGN PENDING :12
[ ]
™E : Available in English version
6m 2.5 2.5 6m0
3.6m
Top view
Side view
12m
84°
Top view
Area adjustment
40'(12)
(10)(5)0
8.3'
(2.5
)(5°~35°)
30°
8°
65.5°
Side view
Weight
™E PA-450Wide angle protection(Coverage: 11m)
2.5m84°
0 5 10 11m
Top view
Side view
Detection System
Alarm Output
Supply VoltagePower Consumption
Features
Mounting PositionOptionalExternal Dimensions
Ambient Temperature
TwinDry contact (semi-conductor)relay outputN/O or N/C selectableReset time: 2sec.24V (AC/DC) 0.25A Max9 to 18V DC (non-polarity)25mAPulse countLED disable switchLow voltage alarmAuto reset memory
Ceiling / wall mount attachmentWall, wall corner (indoor)!15˚C to +55˚C
W70mm " H110mm " D45mm120g
Weight
™E PA-450PI (PET IMMUNE)Wide angle protection(Coverage: 11m)
¡20kg pet immunity with multiple zone technology.
Detection System
Alarm Output
Supply VoltagePower Consumption
Features
Mounting PositionOptionalExternal Dimensions
Ambient Temperature
TwinDry contact (semi-conductor)relay outputN/O or N/C selectableReset time: 2sec.24V (AC/DC) 0.25A Max10 to 18V DC (non-polarity)25mAPulse countLED disable switchLow voltage alarmAuto reset memory
Ceiling / wall mount attachmentWall, wall corner (indoor)!15˚C to +55˚C
W70mm " H110mm " D45mm120g
8.3'(2.5m) 65° 49° 30.8° 14° 7°
84°
0 10' 20' 30' 36'(5m) (10m)(11m)
Top view
Side view
Detection System™E PA-460Vertical curtain protection(Coverage: 16.5m)
Top view
Side view
2.5m
0 5 10 15 16.5m
Alarm Output
Supply VoltagePower Consumption
Features
Mounting PositionOptionalExternal DimensionsWeight
Ambient Temperature
TwinDry contact (semi-conductor)relay outputN/O or N/C selectableReset time: 2sec.24V (AC/DC) 0.25A Max9 to 18V DC (non-polarity)25mA
LED disable switchLow voltage alarmAuto reset memory
Ceiling / wall mount attachmentWall, wall corner (indoor)!15˚C to +55˚C
W70mm " H110mm " D45mm120g
4
Passive Infrared Sensor
SECURITY <SENSOR>
INTERNATIONAL PATENT REGISTRATED : 2 • PATENT REGISTRATED : 1 • UTILITY MODELREGISTRATED : 3 • DESIGN REGISTRATED : 2 / PATENT PENDING : 6 • UTILITY MODELPENDING : 10 • DESIGN PENDING :12
[ ]
™E : Available in English version
™E PA-470LWide angle / Vertical curtain protection(lens replacement)• Wide angle protection
(Coverage: 16m)• Vertical curtain protection
(Coverage: 20m)
2.5m84
°
0 5 10 1516m
Top viewSide view
Top view
Side view
0 5 10 15 20m
1m
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Quad
Dry contact relay output: N/C or N/O(changeover on switch)Reset time: approx. 2sec.30V (AC/DC) 0.25A Max
9 to 18V DC (non-polarity)
28mA
Memory controlLED controlLow voltage
!10˚C to +50˚C
Ceiling, wall mount attachment
Wall, wall corner (indoor)
W90mm " H127mm " D62.5mm
165g
™E PA-480SWide angle protection (180˚)(Coverage: 8m)
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Twin
Dry contact relay output: N/CReset time: approx. 2sec.30V (AC/DC) 0.1A Max
9 to 18V DC (non-polarity)
32mA
Low voltage alarmArea adjustment• downward 20˚ (5positions)
!10˚C to +50˚C
Ceiling / wall mount attachment
Wall, wall corner (indoor)
W90mm " H127mm " D62.5mm
165g
0 5 8m
170°
2.5m
Top view
Side view
5
Passive Infrared Sensor
SECURITY <SENSOR>
INTERNATIONAL PATENT REGISTRATED : 2 • PATENT REGISTRATED : 1 • UTILITY MODELREGISTRATED : 3 • DESIGN REGISTRATED : 2 / PATENT PENDING : 6 • UTILITY MODELPENDING : 10 • DESIGN PENDING :12
[ ]
™E : Available in English version
Weight
™E PA-4810EWide angle protection(Coverage: 12m)
™E PA-4820EVertical curtain protection(Coverage: 25m)
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting PositionOptionalExternal Dimensions
Ambient Temperature
Quad
Dry contact relay output: N/C or N/O(changeover on switch)Reset time: approx. 2sec.30V (AC/DC) 0.25A Max
10 to 30V DC (non-polarity)32mA
Slight motion detectionMemory control LED controlTrouble alarm
Ceiling / wall mount attachmentWall, wall corner (indoor)!10˚C to +55˚C
W90mm " H127mm " D60mm165g
3m
Top view
Side view
0 5 10 15 20 25m
0 5 12m10
84°
3m
Top view
Side view
Anti-masking base unit
Optional Accessories for Passive Infrared Sensor
Flush mount attachment
™E BU-2000(for PA-3000 series)BU-5000(for PA-5000 series)
BU-5300(for PA-5300 series)BU-6700(for PA-6700 series)
™E BU-7000(for PA-7000 series)
™E BCW-401Ceiling / wall mount attachment(for PA-370/410/420/450/460/470/480/4800/6600/6800 series)
BL-5000Wall mount attachment(for all ceiling mount series)
EL-02Sensitivity level checker(for PA-5300 series)
BP-150AE
¡Anti-masking functionality.¡Tamper output.
Detection System
Trouble AlarmOutput
Supply VoltagePower Consumption
Compatible Models
External DimensionsWeight
Mounting Position
Direct reflection system by near infraredDry contact (Semi-conductor) output N/CRating: 24V AC/DC Max. 0.25AContact protection resistor 3.3 ohmsOR-gated with tamper output throughterminal t & y10.5 to 30VDC15mA
PA-6812E, PA-6820E, PA-6805E, PA-6810E, PA-6612E, FS-2000E
Indoor ceiling150mm dia " 15mm120g
6
Passive Infrared Sensor (For outdoor use)
™E MS-100E
¡4 detection patterns are available.(Wide angle • Vertical curtain •long range • Spot)
¡Can be mounted on ceiling orwall.
¡Can be mounted on pole andmetal plate. (with optionalaccessories)
¡Rain-proof construction allowsoutdoor installation.
¡With Day / Night Discriminatingfunction.
™E PA-15WEWide angle protection(Coverage: 15m)
¡Rain proof device.¡Attachable to ceiling, wall, pole.¡Easy angle adjustment.
™E PA-30NELong range protection (Coverage: 30m)
MS-12TE(Dual Zone : Variable Angle up to 90 degrees)
MS-12FE(2 Dual Zones : Variable Angle up to 180 degrees)
Spot
4m2.7m
64°
3m
2m
64°
Wide area
1.2m
0 5 10m
Vertical curtain
1.2m
0 5 10m
Long range1.
2m
0 10 20m
0
2.5m
15m
5 10 15m
Top view Side view
Top view
Side view
2.5m
0 10 20 30m
SECURITY <SENSOR>
Detection System
Alarm Output
Supply VoltagePower Consumption
Features
Mounting Position
Optional
External DimensionsWeight
Ambient Temperature
TwinDry contact relay output: N/C or N/O(changeover on switch)Reset time: approx 2sec. ~ 5min.30V (AC/DC) 0.5A Max10.5 to 30V DC (non-polarity)30mAWide angle 10m Max.Vertical curtain 10m Max.Long range 20m Max.Spot 3m Max.
Pole cover, Pole attachment, Wallmount bracket, Wall / Ceil ingattachment, Magnetic sheet.
Wall, ceiling, pole, metal plate (indoor, outdoor)
!20˚C to +50˚C
W77mm " H171mm " D70mm220g
Detection System
Model
Detection System
Alarm Output
Supply Voltage
Power Consumption
Ambient Temperature
Mounting Position
External Dimensions
Weight
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Twin
MS-12TE
Twin
MS-12FE
Twin " 2
Dry contact relay output: N/C orN/O selectable30V (AC/DC) 0.5A MaxReset time: approx 2sec. ~ 5min.
12 to 30VDC (non-polarity)
35mA 40mA
!20˚C to +50˚C
Indoor/Outdoor
W80mm " H234mm " D91mm
390g 470g
Dry contact relay output: 1cReset time: approx 2sec.30V (AC/DC) 0.5A Max
10.5 to 30V DC (non-polarity)
25mA
Pole attachment, Vise
Indoor, outdoor
!20˚C to +50˚C
72mm dia " 211mm
500g
[UTILITY MODEL PENDING : 1 • DESIGN PENDING : 2 ]
™E : Available in English version
PIR-30WEWide angle protection(Coverage: 30m)
PIR-50NEVertical curtain protection (Coverage: 50m)
¡Protection area especially designed to protectfrom high mounting positions
00 33'
(10m)
11.5' (3.5m)
66' (20m)
100' (30m)
51° 100.7'(30.7m)
100.7'(30.7m)
100.7'(30.7m)
82.3'
(25.1m)
73°
73°
Top viewSide view
33' (10m)
66' (20m)
100' (30m)
135' (40m)
165' (50m)
11.5' (3.5m)
00
10'(3m)
Top view
Side view
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Passive infrared
Dry contact (semi-conductor) output: N.C./N.O.24V (AC/DC) 0.25A (resistive load)
Features
• Low supply voltage alarm• Tamper signal• LED control (L/C)• Alarm LED (ON/OFF)• Sensitivity adjustable between 30%
and 170%
9 to 30V DC (non-polarity)
25mA
Water-proof grommet, Tapping screw
Indoor or outdoor wall
!20˚C to +50˚C
184.5mm dia. " 136mm
1600g
Detection distance
Downward Zone
Horizontal Zone
• External Passive Infrared Sensors are primarily designed for the activation of devices such as Security Cameras, Lights and Sounders.For installations requiring the highest levels of security Takex recommend the use of Active Infrared Beams, Active Microwave or Combination sensors.
• The movement of heavy vegetation such as large bushes, trees etc may cause activations if they are in the sensor field of view.In temperature environments where ambient temperature is similar to body temperature the sensitivity of the sensor can be seriously inhibited.
7
Optional Accessories for Outdoor Passive Infrared Sensor
BP-11Pole cover(for MS-100E)
BP-22Pole attachment(for MS-12TE/12FE)
BW-24Wall mount bracket(for MS-12TE/12FE)
™E BCW-401Wall, ceiling attachment(for MS-100E)
BP-12Pole attachment(for MS-100E)
BR-M5Magnetic sheet(for MS-100E)
BW-14Wall mount bracket(for MS-100E)
BP-01Pole attachment(for PA-15WE/30NE)
BP-02Pole attachment(for PA-15WE/30NE)
WO-2DWall bracket(for HO-150S)
BL-8400Wall mount attachment(PA-8400 Series・PIR-30W・50N)
BP-03Pole attachment(PA-8400 Series・PIR-30W・50N)
BU-8400Embedding attachment(PA-8400 Series)
BV-03Vise attachment(for PA-15WE/30NE)
SECURITY <SENSOR>
8
SECURITY <SENSOR>
Weight
Ultraviolet rays detection10m (7cm lighter flame 10m ahead)
Alkali battery (LR-6) " 2 or 9 to 30V DC
50mA
Open collector (semi-conductor)output N/O30V DC • 50mA MaxDelay time (approx. 10sec)
Ceiling, wall (indoor)120mm dia " 40mm200g
Detection SystemDetection Distance
Power Supply
Power Consumption
Mounting PositionExternal DimensionsWeight
External Output
Flame Sensor
™E FS-1000E(Ultraviolet rays detection system)
¡High sensitivity enables an instant flamedetection.
¡External output enables system extension.¡Versatile, high quality and low cost.
10m
™E FS-2000E(Ultraviolet raysdetection system)
¡High sensitivity enables an instant flamedetection.
¡Detection area adjustment, Tamper, Alarmmemory, Form C output are incorporated inaddition to FS-1000E.
™E FS-3000E
¡Instant flame detection.¡Selectable warning message among 4
languages.¡Battery operation.¡Open collector output.
™E FS-5000E(Ultraviolet rays detection system-Outdoor)
¡Instant flame detection.¡Rain-proof housing.¡Day/Night discernment function.¡Detection time setting.¡Output time set up.
™E FS-6000C/E
¡Instant flame detection.¡Selectable warning message among 4
languages.¡Rain-proof.¡Alarm output Form C.
Detection System
Detection SystemDetection Distance
Power Supply
Power Consumption
Battery Life
Warning Message
External Output
InstallationWeight
Detection DistanceSupply Voltage
Power Consumption
External Output
Mounting PositionExternal Dimensions
Ultraviolet rays detection
Detection System
Detection Distance
Power Supply
Power Consumption
External Output
Ambient Temperature
Installation
Weight
Ultraviolet rays detection
Abt.10meters with 7cm flame
DC10 - 30V (Non-polarity)
35mA or less
Dry contact relay Form CContact capacity: 30V (AC/DC) 0.5A or less
!20˚C to +50˚C
Outdoor, Indoor
550g
Ultraviolet rays detection10m (7cm lighter flame)
Stand by 70µA or lessOperate 300mA or less (at max. volume of speaker activating)Using type-3 alkaline battery approx. 2 years (at stand by)Using exclusive lithium battery approx. 5 years (at stand by)*English *Spanish *French *ItalianNPN open collector output30V (DC) 50mA, one-shot operation ("ON" when outputting)Output time: Same as message output time.Indoor (Ceiling or wall mount)approx. 8.1oz (230g) including battery (accessory) 1.8oz (50g)
Type-3 alkaline battery (LR6) X2 (3V) accessoryExclusive lithium battery (CR17450E-R-2-CM2) X1(3V) optional
10m (7cm lighter flame 10m ahead)10 to 30V DC (non-polarity)
Stand-by: 25mA or lessAlarm: 75mA or less with buzzer
40mA or less without buzzer
Dry contact relay Form CAction: offdelay 2sec.Capacity: 30V (AC/DC) 0.3A
Ceiling, wall (indoor)120mm dia " 40mm150g
MAX.10m
MAX.10m
Detection System
Detection Area
Power Supply
Power Consumption
Warning Message
External Output
Ambient Temp. Range
Installation
Weight
Ultraviolet rays detection
Distance 10m (7cm lighter flame)
DC12V ±2V (non-polarity)
Stand by 35mA or less
Operate 500mA or less
English, Chinese, Korean, Turkish (FS-6000C only)English, Spanish, French, Italian (FS-6000E only)
Dry contact relay form C (alarm: open/close)Contact capacity: 30V (AC/DC) 0.5A or less (resistance load)
!4˚F to +122˚F (!20˚C to +50˚C)
Indoor, Outdoor
approx. 35 oz (1,000g)
™E : Available in English version
[m]
1
8[m]
10
765432
987654321
sensitivity; "L"
15°
Side view
(33ft.)
(20ft.)
1 2 3 4 5 6 7 8 9 10(33ft.)
(20ft.)
[m]
[m]
sensitivity; "L"
12345678
15° Side view
23'[7m][7m] [6m][6m] [3m][3m]23'20'
30'
10'
20'
30'
10'
20'
[10m]
[9m]
[6m]
[3m]
[9m]
[6m]
[3m]
33'
20'10' 10'
9
Combination Sensor
COM-IN-50HF(Coverage: Outdoor 50m)
¡Combination of photoelectr ic beam andmicrowave.
¡And-gated or Or-gated available.¡4 frequencies selectable.¡Environmental module.
Detection system
Alarm output
Supply VoltagePower Consumption
Features
Mounting PositionOptionalExternal DimensionsWeight
Photoelectric beam + MicrowaveDry contact relay output 1CReset time: Detection time + delaytime (approx. 2sec.)30V (AC/DC) 1A Max12 to 30V DC165mAAlarm Output: And-gated or Or-gatedavailableEnvironmental Output4 frequencies selectableAutomatic gain control (AGC) circuitMonitor jack
Outdoor (perimeter)Pole cover (BP-50COM)W104mm " H627mm " D102mmTransmitter 1,850g Receiver 2,000g
Detection system
Alarm output
Supply VoltagePower Consumption
Features
Mounting PositionOptionalExternal DimensionsWeight
Photoelectric beam + MicrowaveDry contact relay output 1CReset time: Detection time + delaytime (approx. 2sec.)30V (AC/DC) 1A Max12 to 30V DC175mAAlarm Output: And-gated or Or-gatedavailableEnvironmental Output4 frequencies selectableAutomatic gain control (AGC) circuitMonitor jack
Outdoor (perimeter)Pole cover (BP-100COM)W130mm " H703mm " D126mmTransmitter 2,120g Receiver 2,270g
[ UTILITY MODEL PENDING : 2 • DESIGN PENDING : 3 ]
SECURITY <SENSOR>
COM-IN-100A(Coverage: Outdoor 100m)
¡Combination of photoelectr ic beam andmicrowave.
¡And-gated or Or-gated available.¡4 frequencies selectable.¡Environmental module.
External Dimensions
Detection System
Model
Alarm Output
Supply Voltage
Features
Optional
Power Consumption
Microwave 24.11GHz
MW-50L
Microwave 24.19GHz
MW-50H
Dry contact relay output 1C30V (AC/DC) 0.5A or less
12 to 30V DC
100mA
Monitor outputAdjustment mode switchAutomatic Gain Control circuit
Pole cover (BP-50MW)
W112mm " H232mm " D102mm
Microwave Sensor
Weight Transmitter 710g Receiver 760g
MW-50(Coverage: Outdoor 50m)
¡2 frequencies (H) and (L) available.¡Automatic Gain Control circuit.¡Adjustment mode switch available.
External Dimensions
Detection System
Alarm Output
Supply Voltage
Features
Optional
Power Consumption
Model MW-100AL MW-100AH
Microwave 24.11GHz Microwave 24.19GHz
Dry contact relay output 1C30V (AC/DC) 0.5A or less
12 to 30V DC
100mA
Monitor outputAdjustment mode switchAutomatic Gain Control circuit
Pole cover (BP-100MW)
W130mm " H307mm " D126mm
Weight Transmitter 930g Receiver 980g
MW-100A(Coverage: Outdoor 100m)
¡2 frequencies (H) and (L) available.¡Automatic Gain Control circuit.¡Adjustment mode switch available.
Detection area 3.3"~6.6"(1m~2m)
Protection distance
3.3"~165"(1m~
50m)
Detection area 3.3"~6.6"(1m~2m)
Protection distance
16.5"~330"(5m~
100m)
Detection area 3.3"~6.6"(1m~2m)
Detection area 3.3"~6.6"(1m~2m)
Protection distance
16.5"~330"(5m~
100m)
Protection distance
3.3"~165"(1m~
50m)
™E PB-4RTNS(E)Twin beam reflective 13ft.(Coverage: 4m)
(Note) Nonsensitive zones depend upon thesensitivity volume.
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
External Dimensions
Weight
Ambient Temperature
Near infrared (reflection type)
Dry contact relay output: N/O orN/C selectableReset time: Detection time + delaytime (approx. 1sec.)30V (AC/DC) 0.3A Max
10 to 30V DC (non-polarity)
55mA or less
!25˚C to +55˚C
Indoor or semi-outdoor
Sensor 15mm dia " 16mmAmplifier W45mm " H120mm " D29mmReflector W69mm " H84mm " D13mm
Sensor 60g Amplifier 95g
™E PB-4RNS(E)Single beam reflective 13ft.(Coverage: 4m)
(Note) Nonsensitive zones depend upon thesensitivity volume.
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
External Dimensions
Weight
Ambient Temperature
Near infrared (reflection type)
Dry contact relay output: N/O orN/C selectableReset time: Detection time + delaytime (approx. 1sec.)30V (AC/DC) 0.3A Max
10 to 30V DC (non-polarity)
45mA or less
!25˚C to +55˚C
Indoor or semi-outdoor
Sensor 15mm dia " 16mmAmplifier W45mm " H120mm " D29mmReflector W69mm " H84mm " D13mm
Sensor 60g Amplifier 95g
™E PB-10TNS(E)Twin beam 33ft.(Coverage: 10m)
¡Sensitivity adjustment(Adjust the sensitivity adjustment controldepending on the protection distance.)
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
External Dimensions
Weight
Ambient Temperature
Near infrared (through type)
Dry contact relay output: N/O orN/C selectableReset time: Detection time + delaytime (approx. 1sec.)30V (AC/DC) 0.3A Max
10 to 30V DC (non-polarity)
55mA or less
!25˚C to +55˚C
Indoor or semi-outdoor
Sensor 15mm dia " 16mmAmplifier W45mm " H120mm " D29mm
Sensor 120g Reflector 95g
™E PB-10NS(E)Single beam 33ft.(Coverage: 10m)
¡Sensitivity adjustment(Adjust the sensitivity adjustment controldepending on the protection distance.)
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
External Dimensions
Weight
Ambient Temperature
Near infrared (through type)
Dry contact relay output: N/O orN/C selectableReset time: Detection time + delaytime (approx. 1sec.)30V (AC/DC) 0.3A Max
10 to 30V DC (non-polarity)
45mA or less
!25˚C to +55˚C
Indoor or semi-outdoor
Sensor 15mm dia " 16mmAmplifier W45mm " H120mm " D29mm
Sensor 120g Amplifier 95g
Protection distance : 33ft. (10m) or less
Transmitter Receiver
10
Miniature Photoelectric Beam Sensor <Amplifier separate type>
SECURITY <SENSOR>
UTILITY MODELPENDING : 1[ ]
™E : Available in English version
Sensitive zonesNonsensitive zones
Reflector
(Transmitter)(Receiver)
Protection distance : 13ft. (4m) or less
Sensitive zonesNonsensitive zones
Reflector
(Transmitter)(Receiver)
Protection distance : 13ft. (4m) or less
Protection distance : 33ft. (10m) or less
Transmitter Receiver
Detection System
™E PR-10B(Surface mount type)
PR-10BU(Flush mount type)(Coverage: Indoor 10m)
¡Single beam for indoor short distance use.¡Reflection type.
Protection distance Reflector
Sensor
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Near infrared (reflection type)
Dry contact relay output: N/CReset time: approx. 1sec30V (AC/DC) 0.5A Max
10.5 to 15V DC (non-polarity)
30mA
!25˚C to +55˚C
L bracket
Wall, pillar (indoor)
W62mm " H157mm " D62mm
220g (PR-10B)
PR-11BEOutdoor 3.3 to 36ft. (1 to 11m)Indoor 3.3 to 49ft. (1 to 15m)
# Protection distance (between sensor/reflector)should be placed in the rated range.
Detection System
Alarm Output
Supply Voltage
Power Consumption
Ambient Temperature
Mounting Position
External Dimensions
Weight
Features
Near infrared (reflection type)
Dry contact relay output: N/O orN/C selectable30V (AC/DC) 0.5A Max
10.5 to 30V DC (non-polarity)
55mA
¡Tamper output¡Monitor jack output
!35˚C to +60˚C
Outdoor / Indoor
Sensor W73mm " H170mm " D71.5mmReflector W93mm " H231.5mm " D100mm
Sensor 430g Reflector 490g
™E PR-5B(Coverage: Indoor 5m)
¡Single beam for indoor short distance use.¡Reflection type.
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Near infrared (reflection type)
Dry contact relay output : 1cReset time : Detection time + delaytime (approx. 1sec)30V (AC/DC) 0.5A Max
10.5 to 26V DC (non-polarity)
37mA
!20˚C to +50˚C
Flush mount plate, L bracket
Wall, pillar (indoor)
W62mm " H106mm " D23.5mm
Sensor 90g Reflector 50g
Protection distance Reflector
Sensor
Transmitter
Receiver
ReflectorSensor
Outdoor : 3.3’ to 36’ (1 to 11m)Indoor : 3.3’ to 49’ (1 to 15m)
11
SECURITY <SENSOR>
Photoelectric Beam Sensor
™E PR-1B(Coverage: 1m)
¡Motionless objects can be detected.¡Direct reflection system.
(no reflector reguired)¡Sensitivity abjustment.¡Slim and compact size.¡Flush mount is available with optional
attachment.
Protection distance
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Near infrared (direct reflection type)
Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 0.5sec)30V (AC/DC) 0.5A Max
10.5 to 22V DC (non-polarity)
60mA
!20˚C to +50˚C
Flush mount plate, L bracket
Wall, pillar (indoor)
W62mm " H106mm " D23.5mm
75g
PATENT REGISTRATED : 3 • UTILITY MODEL REGISTRATED : 2 • DESIGNREGISTRATED : 1 / INTERNATIONAL PATENT PENDING : 1 • UTILITY MODELPENDING : 10 • DESIGN PENDING : 2
[ ]
™E : Available in English version
Weight
™E PB-30TK (K) (2 beams type)(Coverage: Outdoor 30m / Indoor 60m)
™E PB-60TK (K) (2 beams type)(Coverage: Outdoor 60m / Indoor 120m)
™E PB-100TK (K) (2 beams type)(Coverage: Outdoor 100m / Indoor 200m)
¡Double beam AND gated.¡Frost proof cover / AGC circuit / monitor jack
output.
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Ambient Temperature
Near infrared (through type)
Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 1 ~ 3sec)30V (AC/DC) 0.5A Max
10 to 30V DC (non-polarity)
53mA to 80mA
• Double modulation frequency• Frost proof cover• AGC circuit• Monitor jack output
!35˚C to +60˚C
Pole, Pole cover, housing
Outdoor, indoor
W73mm " H170mm " D71.5mm
Transmitter: 380g Receiver: 400g
Protection distance
Receiver
Transmitter
Detection System
™E PB-30SU (Flush mount type)(Coverage: Indoor 30m)
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
External Dimensions
Weight
Ambient Temperature
Near infrared (through type)
Dry contact relay output: N/C or N/OReset time: Detection time + delaytime (approx. 2sec)24V (AC/DC) 0.25A Max
10 to 30V DC (non-polarity)
32mA
!15˚C to +55˚C
Wall, pillar (indoor)
W70mm " H120mm " D45mm
90g
Protection distance Receiver
Transmitter
™E PB-20TE (2 beams type) (Coverage: Outdoor 20m / Indoor 40m)
™E PB-40TE (2 beams type)(Coverage: Outdoor 40m / Indoor 80m)
™E PB-60TE (2 beams type)(Coverage: Outdoor 60m / Indoor 120m)
¡Intelligent twin beam.¡Changeover of modulation frequency: 4 stages.¡Double beam AND gated.¡Frost proof cover / AGC circuit / monitor jack
output.
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Near infrared (through type)
Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 1 ~ 3sec)30V (AC/DC) 0.5 A Max
10 to 30V DC (non-polarity)
55mA to 80mA
• Double modulation frequency• Frost proof cover• AGC circuit• Monitor jack output
!35˚C to +60˚C
Pole, Pole cover, housing
Outdoor, indoor
W73mm " H170mm " D71.5mm
Transmitter: 380g Receiver: 400g
Protection distance
Receiver
Transmitter
™E PB-30TK (W) (2 beams type)(Coverage: Outdoor 30m / Indoor 60m)
™E PB-60TK (W) (2 beams type)(Coverage: Outdoor 60m / Indoor 120m)
¡White cover.¡Double beam AND gated.¡Frost proof cover / AGC circuit / monitor jack
output.
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Near infrared (through type)
Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 1 ~ 3sec)30V (AC/DC) 0.5A Max
10 to 30V DC (non-polarity)
53mA to 80mA
• Double modulation frequency• Frost proof cover• AGC circuit• Monitor jack output
!25˚C to +60˚C
Pole, Pole cover, housing
Outdoor, indoor
W73mm " H170mm " D71.5mm
Transmitter: 380g Receiver: 400g
Protection distance
Receiver
Transmitter
Photoelectric Beam Sensor
12
PATENT REGISTRATED : 3 • UTILITY MODEL REGISTRATED : 2 • DESIGNREGISTRATED : 1 / INTERNATIONAL PATENT PENDING : 1 • UTILITY MODELPENDING : 10 • DESIGN PENDING : 2
[ ]
™E : Available in English version
SECURITY <SENSOR>
Detection System™E PB-50F (4 beams type) (Coverage: Outdoor 50m)
PB-100F (4 beams type)(Coverage: Outdoor 100m)
PB-200F (4 beams type)(Coverage: Outdoor 200m)
¡4-stacked synchronized beam for long distance use.¡Double modulation frequency + PLL circuit
adopted.¡Frost and dow proof cover.
Alarm Output
Supply VoltagePower Consumption
Features
Mounting Position
Optional
External DimensionsWeight
Ambient Temperature
Near infrared (through type)
Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 1sec)30V (AC/DC) 0.5A Max
10 to 30V DC (non-polarity)75mA• Double modulation frequency• PLL circuit adopted• Frost proof cover
!25˚C to +60˚C
Pole, poleattachment, pole-sidecover, heater, flash mount housing
Outdoor, indoor
W104mm " H390mm " D98mm1,300g
Protection distance Receiver
Transmitter
Detection System™E PB-IN-100AT (4 beams type) (Coverage: Outdoor 100m)
¡For anti crawl.
Alarm Output
Supply Voltage
Power Consumption
Features
Optional
External Dimensions
Weight
Ambient Temperature
Near infrared (through type)
Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 1.5sec)30V (AC/DC) 1A Max
10 to 30V DC (non-polarity)
85mA• Double modulation frequency• Four frequency selection• Dual response time system
!25˚C to +60˚C
Pole, poleattachment, pole-sidecover, heater, housing
W104mm " H390mm " D98mm
Transmitter 1,200g Receiver 1,300g
ReceiverTransmitter
Beam received
Beam received
Not received
Not received
™E PB-IN-50HF (4 beams type) (Coverage: Outdoor 50m)
™E PB-IN-100HF (4 beams type)(Coverage: Outdoor 100m)
™E PB-IN-200HF (4 beams type)(Coverage: Outdoor 200m)
¡Intelligent quad beam.¡4-frequencies changeover.¡Beam power selection.¡Auto-gain lock.
Detection System
Alarm Output
Supply VoltagePower Consumption
Features
Mounting Position
Optional
External DimensionsWeight
Ambient Temperature
Near infrared (through type)Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 1.5sec)30V (AC/DC) 1A Max10 to 30V DC (non-polarity)60mA to 85mA• Double modulation frequency• Beam power selection• Auto-gain lock• Frost proof cover!25˚C to +60˚C
Pole, poleattachment, pole-sidecover, heater, flash mount housing
Outdoor, indoor
W104mm " H390mm " D98mmTransmitter 1,200g Receiver 1,300g
Protection distance Receiver
Transmitter
13
SECURITY <SENSOR>
Weight
Detection SystemPB-60TU (2 beams, Flush mount type)(Coverage: Indoor 60m)
¡Changeover of modulation frequency: 4 stages.¡Double beam AND gated.¡AGC circuit / monitor jack output.
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
External Dimensions
Ambient Temperature
Near infrared (through type)
Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 1 ~ 3sec)30V (AC/DC) 0.5A Max
10 to 30V DC (non-polarity)
75mA
!25˚C to +60˚C
Wall, pillar (indoor)
W116mm " H116mm " D69mm
350g
Protection distance Receiver
Transmitter
Photoelectric Beam SensorPATENT REGISTRATED : 3 • UTILITY MODEL REGISTRATED : 2 • DESIGNREGISTRATED : 1 / INTERNATIONAL PATENT PENDING : 1 • UTILITY MODEL PENDING :10 • DESIGN PENDING : 2
[ ]
™E : Available in English version
Weight
14
Photoelectric Beam SensorPATENT REGISTRATED : 3 • UTILITY MODEL REGISTRATED : 2 • DESIGNREGISTRATED : 1 / INTERNATIONAL PATENT PENDING : 1 • UTILITY MODEL PENDING :10 • DESIGN PENDING : 2
[ ]
™E : Available in English version
SECURITY <SENSOR>
Detection System™E PB-100ST (2 beams type) (Coverage: Outdoor 100m)
¡Double modulation frequency.¡Automatic Gain Control.¡Frost and dew proof cover.¡Insect protection.
Alarm Output
Supply Voltage
Power Consumption
Optional
External Dimensions
Ambient Temperature
Mounting Position
Near infrared (through type)
Dry contact relay output: 1cReset time: Detection time + delaytime (approx. 1sec)30V (AC/DC) 0.5A Max
10 to 30V DC (non-polarity)
80mA or less
!25˚C to +60˚C
Outdoor, Indoor
Pole, poleattachment, pole-sidecover, heater, housing
W104mm " H390mm " D98mm
Transmitter/Receiver 1,200g each
Protection distanceWithin 100m (330ft.)
ReceiverReceiverTransmitter
195mm
Beam dia34mm34mm
Beam dia34mm
Weight
™E PH-200SE(Coverage: Outdoor 200m)
™E PH-600SE(Coverage: Outdoor 600m)
¡External environmental diagnostic function.
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Ambient Temperature
Near infrared (through type)
Dry contact relay output: N/CReset time: Detection time + delaytime (approx. 2sec)30V (AC/DC) 0.5A Max
10.5 to 30V DC (non-polarity)
45mA
SEC Circuit board, pole, long hood
Outdoor, indoor
!25˚C to +55˚C
W124mm " H170mm " D240mm (PH-200SE)
2,000g (200SE)・8,000g (600SE)
Protection distance
Transmitter Receiver
Explosion-proof Photoelectric Beam Sensor
™E PB-100EX(Coverage: Outdoor 100m)
™E PB-200EX(Coverage: Outdoor 200m)
™E PB-400EX(Coverage: Outdoor 400m)
¡Ideal for monitoring hazardous locations.¡For beam protection.
Detection System
Explosion-proof Construction
Applicable Locations
Applicable Gases
Labor MinistryApproval No.
Supply VoltagePower ConsumptionAmbient Temperature
Alarm Output
Near infrared (through type)Intrinsically safe explosion proofing+ pressure resistant explosionproof constructionClass 1 and 2 hazardous locations2G4(Explosion class: 2) (Ignition class: G4)Transmitter: No.T62011Receiver: No.T62010Dry contact relay output: N/CReset time: Detection time +deraytime (approx 1 sec)220V (AC/DC) 0.5A or 10VA Max100V AC 50/60Hz or 200V AC 50/60Hz5.5VA!10˚C to +40˚CW198mm " H258mm " D350mm20,000g ~ 25,000g
Protection distance
External DimensionsWeight
PATENT REGISTRATED : 1 • DESIGNREGISTRATED : 1[ ]
SECURITY <SENSOR>
Optional Accessories for TA series tower
PTKHQuick release brackets for the KH beam units. Provided with KH beamunit.
PTSThermostat, acting on the basis of temperature variation. It activates - deactivates the heater. It is recommanded at least one thermostat per column.
PTHHeater, 12v 250mA. Indispensable when there is a risk of condensation. It is recommanded to install one heater under each beam unit.
CRFBConcrete floor base. It contains a plate to support the level offering a wide and clear surface support. Indispensable when the ground surface is not suitable to directly anchor too.
TAPSAnti-Climb tamper. Activates an alarm when a intruders attempt to climb over the tower by supporting themselves on the lid. Activation accurse when a pressure greater than 20Kg is applied.
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Ambient Temperature
Near infrared (through type)Dry contact relay output: 1cReset time: Detection time delaytime (approx. 1.5sec)30V (AC/DC) 1A Max10 to 30V DC (non-polarity)60mA to 85mA
Double modulation frequencyBeam power selectionAuto-gain lock
180° Free standing ColumnPB-50HF/KH 50m Quad tower beamPB-100HF/KH 100m Quad tower beamPB-200HF/KH 200m Quad tower beamPB-100KH/AT 100m Quad Anti-Crawl tower beam
SECURITY <SENSORSECURITY <SENSOR>
Colonnes série TA pour fixations libres et murales
180° Free standing ColumnTAS100 1.0m Single sided / 180º / Beam towerTAS150 1.5m Single sided / 180º / Beam towerTAS200 2.0m Single sided / 180º / Beam towerTAS300 3.0m Single sided / 180º / Beam tower 360° Free standing ColumnTAD100 1.0m Double sided / 360º / Beam towerTAD150 1.5m Double sided / 360º / Beam towerTAD200 2.0m Double sided / 360º / Beam towerTAD300 3.0m Double sided / 360º / Beam tower180° Wall !xed Column TAW100 1.0m Single sided / 180º / Beam towerTAW150 1.5m Single sided / 180º / Beam towerTAW200 2.0m Single sided / 180º / Beam towerTAW300 3.0m Single sided / 180º / Beam tower
TAMPER PROTECTION
Floor instalation Towers (TAS & TAD) or wall (TAW).Standard heights range from 1, 1’5, 2 to 3m covering all possible needs. Furthermore, specific measures can be manufactured upon client’s requests.Large range of accessories are available to solve possible difficulties during the intallation. Guy-wires for extreme windy areas, extra-large lateral supports for specific installations, concrete floor bases for difficult grounds, heaters and thermostat to face risk of condensation that can interfere in the good functioning of infrared devices.Tamper switch: Anti-sabotage system is included in all our beam towers, avoiding manipulations of the equipments inside.
DESCRIPTION
The Active Infrared Beam sensors installed in traditional ways; undisguised mounted on poles, and/or anchored to walls, are easily detectable and allow intruders to surpass such systems. Nevertheless the same infrared beam installation mounted on a tower tackles this issue since intruders are unable to determine the number, position, type and orientation of the security sensors installed inside.
MATERIALS
The central body is an anodized aluminum column which offers a great resistance to oxydation. Beam devices are installed over the screw rails included with the hardware kit provided. Using the BEAG accessory you can obtain easy and quick fixation saving time and workforce (TAKEX Beams only).The main structure is covered by a dark vandal resistant polycarbonate external cover, totally transparent to the infrared. Its strong resistance and blow absorption, prevents acts of vandalism from dammaging the security system.
15
SECURITY <SENSOR>
Detection System
Weight
Solar Powered Beam Sensor System
BA-6SL (Rain-proof)
This model consists ofOne solar panelOne power unit
¡Which will be sold separately from PB-IN-75SW.
Output Voltage
Inner Battery
Installation
DC6V, 12mADC12V
6V, 7.2Ah
Outdoor
Solar panel : 900gPower unit : 2,700g
™E PB-IN-75SW (E) (4 beams type) (Coverage: Outdoor 75m)
¡Extreamly low current consumption.¡4 frequencies selection.¡Double modulation beam.¡Automatic gain lock.
Alarm Output
Power Supply
Power Consumption
Weight
External Dimensions
Ambient Temperature
Mounting Position
Near infrared (through type)
Dry contact relay form CReset time: Detection time + delaytime (approx. 2secs)30V (AC/DC) 1A
5 to 8V DC or 10 to 30V DC (with polarity)
5 to 8V DC : 6mA (TR. side 3.7mA) orless when armed
10 to 30V DC : 25mA (TR. side 15mA)or less when armed
!25˚C to +60˚C
Outdoor
Transmitter 1,200g / Receiver 1,300g
W104mm " H390mm " D98mm
TAKEX new system saves a lot ofinstallation work.This system consists of
PB-IN-75SW (E) : Beam sensorANDBA-6SL : Solar panel + power unit
With this system, No wiring will berequired for transmitter. And onlysignal wiring will be required forreceiver.
Protection distanceWithin 75m
ReceiverReceiver
Transmitter95mm
95mm
134mm
Beam dia34mm34mm
Beam dia34mm
1.8m
at p
rote
ctio
ndi
stan
ce 7
5m
™E : Available in English version
16
SECURITY <SENSOR>
™E : Available in English version
Optional Accessories for Photoelectric Beam Sensor
KH-120Housing case(for outdoor typesensor)
KH-120SHousing case(stainless steel type)(for outdoor typesensor)
BR-5 Reflector(for PR-5B/PB-10S/4RT)BR-10 Reflector(for PR-10B/10BU)
™E BP-200FPole cover(for PB-50F/100F/200F/PB-IN-50F/100F/200F/PB-IN-100AT)
SEC circuit boardEnvironmental level check(for PH-200SE/600SE)
BP-5B Flush mount plateBP-5D Flush mount plate(for PR-1B/PR-5B)
BP-5CFlush mount plate(for PB-10Sa/Sb/4RT/PR-5B (for reflector)
BL-5 L fittings(for PR-1B (sensor) PR-5B (sensor,reflector) PB-10Sa/Sb/4RT (reflector)BL-10 BL-30(for PR-10B) (for PH-50B)
™E HTF-24E (24V DC)HTF-100 (100V AC)
Heater (for PB-50F/100F/200F/PB-IN-50F/100F/200F/PB-IN-100AT)
BP-60TEPole cover(for PB-30TK/60TK/PB-20TE/40TE/60TE)
BH-30hood attachment(for PH-50B)
™E BP-60APole attachment(for PB-30TK/60TK/PB-20TE/40TE/60TE)
Long hoodhood attachment(for PH-200SE)
BS-50FPole side cover(for PB-50F/100F/200F/PB-IN-50F/100F/200F/PB-IN-100AT)
BU-50FFlush mount attachment(for PB-50F/100F/200F/PB-IN-50F/100F/200F/PB-IN-100AT)
17
SECURITY <SENSOR>
Optional Accessories for Shutter Sensor
Shutter Sensor
PR-S3(Distance: 5 to 40cm)
¡Double beam.¡Built-in operation LED output point.¡Built-in attenuation LED.
SH-M5(Distance: 3 to 12cm)
BZ-S2Sensor bracket(for PR-S3 • SH-M5)
BF-S3Sheet bracket(for BR-S3/M5)
BS-S3Sensor bracket(for over slide shutter use)(for PR-S3 • SH-M5)
BR-S3Reflection sheet(for PR-S3)
BR-M5Magnetic sheet(for SH-M5)
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Near infrared (reflection type)
Dry contact relay output: 1cResponse time: 1 to 2sec30V (AC/DC) 0.5A Max
10 to 30V DC (non-polarity)
30mA
LED lights up
Sensor bracket, sheet bracket
Shutter case, lintel (indoor)
!20˚C to +50˚C
W97.5mm " H50mm " D40mm
115g
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Magnetic modulation
Dry contact relay output: 1cResponse time: 1 to 2sec30V (DC) 0.5A Max
10 to 30V
38mA
Sensor bracket, sheet bracket
Shutter (indoor)
!20˚C to +50˚C
W92mm " H74mm " D36mm
95g
15¡
Reflection sheet 2
Reflection sheet 1
Reflection sheet 3
Double beam
Distance5 ~ 40cm
Distance3 ~ 12cm
SlatSensor
Magnetic sheet
Shutter surface
[ DESIGN REGISTRATED : 1 / PATENT PENDING : 2 • UTILITY MODEL PENDING : 3 • DESIGN PENDING : 1 ]
18
SECURITY <SENSOR>
Glass Sensor
Optional Accessories for Glass Sensor
GS-1000(Non-contact microphone type)(Coverage: 4m " 6m)
¡Non-contact microphone.¡Ceiling / wall mount type.
™E GS-1100E(Non-contact microphone type)(Coverage: 7m " 8m)
¡Non-contact microphone.¡Wall mount type.
GS-02 (Straight cord)GS-02C (Curled cord)(Coverage: radius 180cm max)
¡Piezoelectric type.¡Contact relay output.¡Memory reset function.
EG-1000Glass sensor operation cheker(for GS-1000/1100)
KE-347TGlue(for GS-02/02C)
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Ultrasonic
Dry contact relay output: 1cReset time: approx. 2sec24V (DC) 0.5A Max
10.5 to 20V DC (non-polarity)
50mA
Glass checker
Wall, ceiling (indoor)
!10˚C to +50˚C
147mm dia " 39mm
170g
Detection System
Alarm Output
Supply Voltage
Power Consumption
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Ultrasonic
Dry contact relay output: N/CReset time: approx. 2sec30V (AC/DC) 0.1A Max
9 to 20V DC (non-polarity)
30mA
Glass checker
Wall (indoor)
!10˚C to +50˚C
W70mm " H110mm " D32mm
120g
Detection System
Alarm Output
Supply Voltage
Power Consumption
Features
Mounting Position
Optional
External Dimensions
Weight
Ambient Temperature
Piezoelectric type
Dry contact relay output: N/CReset time: approx. 2sec30V (AC/DC) 0.5A Max
10.5 to 15V (non-polarity)
20mA
Memory reset
Glass checker, Glue
Surface of glass (indoor)
!30˚C to +55˚C
37mm dia " 15mm
30g (GS-02) 50g(GS-02C)
180cm
4m max.6m m
ax.
8m max.
7m m
ax.
[ UTILITY MODEL PENDING : 1 • DESIGN PENDING : 2 ]
™E : Available in English version
19
SECURITY <SENSOR>
Magnetic Switch
MG-103S¡Mounting Position: Exposed type¡Operating distance: 15mm max¡Alarm output: N/C¡Features: Testing hole for loop
check / Removable cover Withspacer, stopper
¡W50mm " H14mm " D12mm¡Weight: 20g
MG-104S¡Mounting Position: Exposed type¡Operating distance: 20mm¡Alarm output: N/C¡Features: Easy wiring, just only
to insert wire into wiring hole,and tighten the screw withspacer, stopper
¡W48.5mm " H11.5mm " D9mm¡Weight: 20g
MG-104¡Mounting Position: Exposed type¡Operating distance: 20mm¡Alarm output: N/C¡Features: Easy wiring, just only
to insert wire into wiring hole,and tighten the screw
¡W48.5mm " H11.5mm " D9mm¡Weight: 20g
!AMS-9¡Mounting Position: Exposed type¡Operating distance: 12mm¡Alarm output: N/C¡Features: Super minia-turized
magnetic switch / Lead wiretype
¡W25mm " H5.5mm " D6mm¡Weight: 6g
!AMS-10C¡Mounting Position: Exposed type¡Operating distance: 20mm¡Alarm output: N/C¡Features: Miniaturized magnetic
switch / Lead wire type¡W33.5mm " H8.5mm " D14.5mm¡Weight: 16g
!AMS-17¡Mounting Position: Concealed type¡Operating distance: 8mm¡Alarm output: N/C¡Features: Super minia-turized
magnetic switch / Lead wiretype
¡11mm dia " 16mm¡Weight: 10g
!AMS-25B¡Mounting Position: Concealed type¡Operating distance: 20mm¡Alarm output: 1c¡Features: Lead wire type¡24mm dia " 30mm¡Weight: 30g
!AWS-21¡Mounting Position: Concealed type¡Operating distance: 30mm¡Alarm output: N/C¡Features: Magnetic switch for
wide gap¡Switch: 11mm dia " 33mm
Magnet: 11mm dia " 37mm¡Weight: 18g
[ DESIGN REGISTRATED : 1 ]
™E : Available in English version ! : Required to ask lead time in advance : Manufactured after order confirmation
20
SECURITY <CONTROL PANEL>
Warning Bell ¥ Siren
Flashlight Auto-dialer
General public lineCommunication destination
Bell box
Control Panel
Squaretype
Rotatingtype
Bell Siren
Intrusion Sensor
Passive infrared sensor
Emargencypush-button
Fire Sensor Gas Sensor
Photoelectricbeam sensor
Photoelectricbeam sensor
Shutter sensor Magnetic switch
Fire Sensor
Key Switch ¥ Card Switch
Model No.
Weight
Multi-channel Control Panel
COV-150 (15ch)
COV-300 (30ch)
¡100V AC ±10% power supply.¡Loop check function.¡Arm / Disarm LED.¡Back-up battery.¡5 alarm time adjustments: continuous, 10sec.,
20sec., 30sec., 60sec.
Supply Voltage
Sensor Power
Back-up Battery
External Output
Alarm Sound
External Dimensions
Alarm Input
COV-150 COV-300
100V AC ±10%
12V DC (13.8V) 1.2A
12V DC 2.0Ah
N/C 15ch N/C 30ch
Total output Form CArmed/Disarmed output Form C
Electric siren
W275mm ! H460mm ! D100mm
7,000g
[ UTILITY MODEL PENDING : 1 ]
21
Sensor Speaker (vocal guide / watch man)
SECURITY <SENSOR SPEAKER • SENSOR SWITCH>
™E PV-12(12V DC • with alarm output)
PV-12A(100V AC • with alarm output)
PV-12AC(100V AC • with AC plug cord / Vise mount type)
¡You can one-touch Recording / playback withhorn speaker type.
¡Recording time is 8sec max.¡You can record only by speaking to microphone.
™E PVW-12TE
¡Two recordable messages with playback.¡You can select message for day and night.¡Contact input can trigger messages.¡Reliable PIR with dual zone system.¡microphone and jack are equipped for
recording message.¡Rain proof housing.
Sensor speaker sends a messagesuch like guidance or warningautomatically when the built-insensor detects people.Sensor speaker with contact outputmodel is available, so this can beused as burglar alarm for securitypurpose.
Watch yoursteps please
Do not enter
from here
Model
Model
Detection System
Detection System
Coverage Area
Coverage Area
Supply Voltage
Supply Voltage
Voice Output
Current Consumption
Alarm Output
Contact Output
PV-12
PVW-12TE
PV-12A PV-12AC
""
Passive infrared
Passive infrared
Wide angle protection(Coverage 12m max)
Horizontal coverageMax. detection distance 12mDetection angle 90˚
12V DC
10 to 30V DC
2W
55mA Max. for standby300mA Max. for operationDry contact relay output NO/NC selectablewith a switchContact capacity: 30V (AC/DC), 0.5A Max.Contact operation: One shot operation
Approx. 2 sec.
100V AC
Dry contact relayoutput: 1cReset time :approx 8sec30V (AC/DC) 0.5A
Dry contact relayoutput: N/OReset time :approx 8sec30V (AC/DC) 5A
1,000g 1,200g 1,650gW115mm ! H172mm ! D289mm
W80mm ! H234mm ! D91mm480g
External Dimensions
External DimensionsWeight
Weight
[ DESIGN PENDING : 2 ]
™E : Available in English version
PBS-15T
¡Detection distance: 15m¡Frequency is selectable for L or H to avoid
cross talk.¡Response time is adjustable between 0.05
sec. and 0.7 sec.¡AGC circuit¡Frost proof cover
Detection SystemSupply Voltage
Current Consumption
Alarm Output
Simultaneous breaking of 2 beams
10 to 18V DC (Non-polarity)Transmitter: 24mA Receiver:250mA
Dry contact relay output N.C./N.O.selectable30V AC/DC 0.5A (resistive load)Contact action: Interruption time(Min.2 sec.)
W73mm ! H332mm ! D67.2Transmitter: 560g Receiver: 620g
External DimensionsWeight
22
SECURITY <SENSOR SPEAKER • SENSOR SWITCH>
Sensor Switch
™E MS-15WEWide angle protection(Coverage : 15m)
™E MS-30NEVertical curtain protection(Coverage : 30m)
¡Sensor switch also detects sound.¡Rain-proof construction allows outdoor installation.¡Can be mounted on ceiling, wall or pole.¡With Day / Night Discriminating function.¡Timer function. (approx. 2sec to 10min)
Detection System
Detection System
Alarm Output
Alarm Output
Supply Voltage
Supply Voltage
Power Consumption
Power Consumption
External Dimensions
External Dimensions
Weight
Weight
Passive infrared + sonic
Passive infrared
Dry contact relay output : 1cReset time : approx. 2sec to10min30V (AC/DC) 0.5A Max
Dry contact relay output : N.C/N.O selectableOutput time : detection time + Offdelay
approx. 5sec to 5min30V (AC/DC) 0.5A
10.5 to 30V DC
10.5 to 30V DC (non polarity)
30mA
40mA
500g
220g
72mm dia ! L212mm
W77mm ! H171mm ! D70mm
™E : Available in English version
™E MS-60EDirectional detection(Coverage : 0.5 to 6.0m)
¡Direction Conscious Sensor.¡Rain proof housing.¡Adjustable output timer. (approx. 5sec to 5min)¡Selectable day or night time operation.
• External Sensor Switchs are primarily designed for the activation of devices such as Security Cameras, Lights and Sounders.For installations requiring the highest levels of security Takex recommend the use of Active Infrared Beams, Active Microwave or Combination sensors.
• The movement of heavy vegetation such as large bushes, trees etc may cause activations if they are in the sensor field of view.In temperature environments where ambient temperature is similar to body temperature the sensitivity of the sensor can be seriously inhibited.
23
Detection System
Alarm Output
Supply Voltage
Power Consumption
Ambient Temperature
External Dimensions
Weight
Supply Voltage
Weight
Detection System
SECURITY <HOMEY GOODS • VOICE SPEAKER • PRESENCE TIMER SENSOR>
Detection area
Power Supply
External Dimensions
Passive infra-red
3m ! 30˚
Type 1 alkaline battery ! 4 (accessory)
W250mm ! H510mm ! D580mm
1,700g
Homey Goods
Watch DogSDT-101¡He detects a moving human within 3m in front
with built-in PIR, barks 3 times (total 4.5sec.),and make flashes of his eyes.
¡Siberian husky model.
Voice Speaker
™E AV-100E¡To give an audio message after being
triggered by a PIR etc.¡Recording time is 8sec., Max.¡You can record only by speaking into
microphone.
Passive infrared
Dry contact (semi-conductor)output: N.O.24V (AC/DC) 0.25A (resistive load)
9 to 18V DC (with polarity)
25mA
W73mm. ! H332mm ! D67.2
#15ºC to +55ºC
Mounting Position Indoor ceiling
Weight 230g
Presence Timer Sensor
SA-750E
™E : Available in English version
Voice Output
Alarm Input
External Dimensions
12V DC
2W Max
Dry contact N/O
W115mm ! H172mm ! D289mm
1,000g
(Front view) [Wide] (Front view) [Narrow]
24
Weight
External Dimensions
Mounting Position
Ambient Temperature
Power Consumption
Supply Voltage
Alarm Output
Detection System
Auto Door Sensor (Passive Infrared)
ACCESS DOOR SENSOR SYSTEM
™E : Available in English version
UTILITY MODEL PENDING : 1DESIGN PENDING : 2[ ]
™E PS-520E(White, Silver)(Coverage : H4m ! W2.4m)
Passive Infrared
Dry contact relay output: 2cHold time : Adjustable approx.0.25sec to 60sec30V (AC/DC) 1A
12 to 24V DC
40mA / DC 70mA / AC
#10˚C to +50˚C
Wall, Ceiling (indoor)
W160mm ! H60mm ! D40mm
170g
1.2m 2.4m
4m
Front View
<Single door> <Double door>
35
0.5m
Adjustable
0.5m
Adjustable
angle 20
20
Side View
<Wall mount> <Ceiling mount>
25
External Dimensions
Detection System
ACCESS DOOR SENSOR SYSTEM
Auto Door Sensor (Photoelectric Beam)
™E : Available in English version
™E DA-101E(Bronze, Silver, White, Black)
¡Near infrared beam type.¡Ultra-slim 30mm body.¡Excellent external light immunity.¡Selectable frequency.
™E DA-301E(Bronze, Silver, White, Black)
¡Near infrared beam type.¡Super-slim 30mm body.¡High-density detection pattern with 4 lines
depth and each 8 areas per line.¡Stationary detection.¡Excellent external light immunity.¡Selectable frequency.
DA-800(Bronze, Silver, White, Black, Mirror)
¡Near infrared beam type.¡Side of l intel or below of l intel, both of
installation patterns are available.¡Excellent external light immunity.
Max Installation Height
Area Adjustable Angle
Power Supply
External Output
Output Holding Time
Stationary Detection Time
Ambient Temperature
Weight
External Dimensions
Power Consumption
Near infrared beam direct reflection
3,000mm
Main body adjustable angle: 0˚ to +10˚Depth: 1lineWidth: adjustable by area switch
12 to 110V AC or DC ± 10%
1.8VA or less at 100V AC1.0VA or less at 12V AC 80mA or less at 12V DC1.3VA or less at 24V AC 40mA or less at 24V DC
Dry contact relay N/O, 50V DC0.1A or less
Approx. 0.5 seconds
2, 15, 60 and 180sec. selectable by dip switch
#20˚C to +60˚C
190g
W212mm ! H65mm ! D35mm
Detection System
Max Installation Height
Area Adjustable Angle
Power Supply
Power Consumption
External Output
Output Holding Time
Stationary Detection Time
Ambient Temperature
Weight
External Dimensions
Near infrared beam direct reflection
3,000mm
Main body adjustable angle: 0˚ to +5˚Depth: 1line to 4 linesWidth: Adjustable by switch
12 to 24V AC or DC ± 10%
1.3VA at AC24V, 1.0VA at AC12V40mA at DC24V, 80mA at DC12V
Dry contact relay N/O, 50V DC0.1A or less
Approx. 0.5 seconds
2, 15, 60sec. and selectable by dip switch
#20˚C to +60˚C
190g
W212mm ! H65mm ! D30mm
Detection System
Max Installation Height
Area Adjustable Angle
Power Supply
External Output
Ambient Temperature
Weight
Power Consumption
Near infrared beam direct reflection
2,500mm
Max 60˚
100V AC 50/60Hz
3VA or less
Dry contact relay N/O, 100V AC0.3A or less
#20˚C to +60˚C
230g
W230mm ! H46mm ! D50mm
10°
2.5m 8.2'
2.0m 6.6'
1.5m 4.9'
1.0m 3.3'
0.5m 1.6'
0.5m 1.6'
1.0m 3.3'
1.5m 4.9'
2.0m 6.6'
2.5m 8.2'
3.0m 9.9'
0m 0'
0
(m ) 2.0 6.6'
2.0 6.6' 0
1.5 4.9'
1.5 4.9'
1.0 3.3'
1.0 3.3'
0.5 1.6'
0.5 1.6'
0.5m 1.6' 1.0m 3.3' 1.5m 4.9' 2.0m 6.6' 2.5m 8.2' 3.0m 9.9'
Side viewFront view
2m 0.94m
Front view Side view
2.5m
0.5m
2.65m1.2m 1.6m
Front view Side view(Single door) (Double door)
3m
26
External Dimensions
Detection System
ACCESS DOOR SENSOR SYSTEM
Auto Door Sensor (Photoelectric Beam)
™E : Available in English version
DA-3000(Silver, Bronze, White, Black, Soutien collar, Mirror)
DA-4800H(Silver)
DA-6500E(Gold)
Max Installation Height
Area Variable Range
Power Supply
External Output
Output Holding Time
Stillness Holding Time
Ambient Temperature
Weight
External Dimensions
Power Consumption
Near infrared beam direct reflection
3,200mm
Start area: 0˚ to 10˚ (Set using the area adjustment lever)Presence area: 0˚ to 8˚ (Set using the area adjustment lever)Monitor area: 2 to 5 rows (Set using the DIP switch)Single/Both sliding: Set using the area mask
12 to 100 VAC or DC ±10% 50/60Hz
3.5 VA max. for 100V AC1.5 VA for 12V AC, 2.0 VA for 24V AC80mA for 12V DC, 50mA for 24V DCDry contact relay output N.O.50V DC: 0.1A (resistive load)Approx. 0.5 sec
Start area: 2 sec., 15 sec., 60 min., InfinityPresence area: 2 sec., 15 sec., 60 min., Infinity(Set using the DIP switch)
#20˚C to +60˚C
250g
W230mm ! H66.5mm ! D33.5mm
Detection System
Max Installation Height
Area Variable Range
Power Supply
Power Consumption
External Output
Output Holding Time
Stillness Holding Time
Ambient Temperature
Weight
External Dimensions
Near infrared beam direct reflection
4,200mm
Fine adjustment angle of the sensor body: 0˚ to 10˚ (5 levels)Stepping: 1 to 4 rows (Set using the DIP switch)Single/Both sliding: Set using the area adjustment lever Position 1 to 5
12 to 100 VAC or DC ±10% 50/60Hz
3.0 VA for 12V AC, 3.0 VA for 24V AC150mA for 12V DC, 75mA for 24V DC
Dry contact relay output N.O.50V DC: 0.1A (resistive load)
Approx. 0.5 sec
Limited stillness detection (2 sec., 60 sec., 10 min., Infinity)
#20˚C to +60˚C
350g
W260mm ! H75mm ! D43mm
Detection System
Max Installation Height
Area Adjustable Angle
Power Supply
External Output
Ambient Temperature
Weight
Power Consumption
Near infrared beam direct reflection
6,500mm
Max 15˚
12 to 100 VAC or DC ±10% 50/60Hz
2.8 VA for 12V AC, 2.8 VA for 24V AC180mA for 12V DC, 90mA for 24V DC
Dry contact relay output N.O.50V DC: 0.1A (resistive load)
#20˚C to +60˚C
830g
W2321mm ! H101.8mm ! D90.5mm
m m m
Front view Side view
m
m m m
Front view Side view
m
m m
Front view Side view
m
m m
Front view Side view
m
15° 15°
m m
Front view Side view
m
m m m
Front view Side view
m
27
28
AAMS-10C 19AMS-17 19AMS-25B 19AMS-9 19AV-100E 23AWS-21 19
BA-6SL 15BCW-401 5 • 7BF-S3 17BH-30 16BL-10 16BL-30 16BL-5 16BL-5000 5BL-8400 7BP-01 7BP-02 7BP-03 7BP-11 7BP-12 7BP-150AE 5BP-200F 16BP-22 7BP-5B 16BP-5C 16BP-5D 16BP-60A 16BP-60TE 16BR-10 16BR-5 16BR-M5 7 • 17BR-S3 17BS-50F 16BS-S3 17BU-2000 5BU-5000 5BU-50F 16BU-5300 5BU-6700 5BU-7000 5BU-8400 7BV-03 7BW-14 7BW-24 7BZ-S2 17
B
CCOM-IN-100A 9COM-IN-50HF 9COV-150 20COV-300 20
DDA-101E 25DA-3000 26DA-301E 25DA-4800H 26DA-6500E 26DA-800 25
HHTF-24E 16HTF-100 16
EEG-1000 18EL-02 5
FFS-1000E 8FS-2000E 8FS-3000E 8FS-5000E 8FS-6000C/E 8
GGS-02 18GS-02C 18GS-1000 18GS-1100E 18
KKE-347T 18KH-120 16KH-120S 16
MMG-103S 19MG-104 19MG-104S 19MS-100E 6MS-12FE 6MS-12TE 6MS-15WE 22MS-30NE 22MS-60E 22MW-100A 9MW-50 9
PPA-15WE 6PA-30NE 6PA-370 3PA-450 3PA-450PI 4PA-460 4PA-470L 4PA-480S 4PA-4810E 5PA-4820E 5PA-5312E 1PA-5325E 1PA-6412PI 3PA-6612E 1PA-6805E 2PA-6810E 2PA-6812E 2PA-6820E 2PA-7012E 2PA-7030E 2PA-7100E 3
PA-8410E 2PA-8420E 2PA-IN-5012F 1PA-IN-5030F 1PB-100F 13PB-100ST 14PB-100TK(K) 12PB-10NS(E) 10PB-10TNS(E) 10PB-200F 13PB-20TE 12PB-30SU 12PB-30TK(K) 12PB-30TK(W) 12PB-40TE 12PB-4RNS(E) 10PB-4RTNS(E) 10PB-50F 13PB-60TE 12PB-60TK(K) 12PB-60TK(W) 12PB-60TU 13PB-IN-100AT 13PB-IN-100HF 13PB-IN-200HF 13PB-IN-50HF 13PB-IN-75SW(E) 15PBS-15T 21PB-100EX 14PB-200EX 14PB-400EX 14PH-200SE 14PH-600SE 14PIR-30WE 6PIR-50NE 6PR-10B 11PR-10BU 11PR-11BE 11PR-1B 11PR-5B 11PR-S3 17PS-520E 24PV-12 21PV-12A 21PV-12AC 21PVW-12TE 21
SSA-750E 23SDT-101 23SEC circuit board 16SH-M5 17
WWO-2D 7
OTHERLong hood 16