MICS Data Processing Workshop
CSPRO Applications
Creating a Data Entry Application
We’ll now create a data entry application The application will make use of the test
dictionary and form Before creating the application, I’ll briefly
discuss– order of operations in CSPRO– data entry path– most common data entry commands
CSPRO Procedure Types
– Global procedure (proc global) logic executed when application begins/ends
– Form file procedure (proc form_file_name) logic executed before/after each case
– Level procedure (proc level_name) logic executed before/after level
– group procedure (proc group_name) logic executed before/after a form or roster
– variable procedure (proc variable_name) logic executed before/after variable’s field entered
Preproc and Postproc
Procedures are broken into two parts– Preproc
logic executed before item for example, skip a variable
– Postproc logic executed after item for example, check if data entered is consistent for example, skip to a variable
If no explicit statement, logic is in the postproc by default
Order of Operations
Global proc Form file preproc
– Level 1 preproc Form 1.1 preproc
– Field 1.1.1 preproc– Field 1.1.1 postproc– ...other form 1 fields
Form 1.1 postproc ...other level 1 forms Level 2 preproc
– Form 2.1 preproc Field2.1.1 preproc Field 2.1.1 postproc
– Form 2.1 postproc– ...other level 2 forms
Level 2 postproc
– Level 1 postproc
Form file postproc
The Data Entry Path
The data entry path contains all of the questions that a respondent should be asked
It is determined by– the type of the questionnaire– the responses to questions in conjunction
with questionnaire skips questionnaire filters
Controlling the Data Entry Path
CSPRO allows one to control completely the data entry path
The first step is to– open DE application– go to options --> data entry– select system controlled– (while you are there, make all alphanumeric
variables upper case)
Questionnaire Skips
CSPRO has 2 ways of implementing skips– The skip to command
if the variable being skipped to is in a single record To skip to a variable or group useskip to variable_name;
skip to group_name;
– The skip to next command if the var. being skipped to is in a multiple record
Reentering
To force the data entry operator to reenter a field (e.g., if the data entered are inconsistent) usereenter;
if command
Use to check for a condition:if HH9 <> 1 then
skip to HH16;endif;
if not HH6 in 1,2 thenreenter;
endif;
Ending a Level
You must manually end a level if– the last variable in the data path is not the
last variable on the questionnaire– you have entered the last woman or under-
five questionnaire This is accomplished using the endlevel
command
The ENDLEVEL Command
The effect of the endlevel command depends upon its context– In field/roster/form proc, passes control to the
level postproc– In level preproc or postproc, passes control to
postproc of next highest level– In postproc of level 1, pass control to the
form file’s postproc
Ending a Group
A group is a record or roster A group is ended by the endgroup command The effect of the command depends upon
context:– In an item procedure, passes control to the
current group’s postproc– In the preproc of the group, skips the entire group
and passes control to the group’s postproc
Working Variables
Working variables must be declared in the global procedure
Numeric working variables can be declared together– numeric var1 var2;
Alphanumeric working variables are declared separately– alpha(length) avar1;– alpha(length) avar2;
Setting Parameters
Global parameters should be declared in the preproc of the forms procedure– e.g., minimum age at first birth
Assign a value to a working variable created for the purpose
Comment your parameter using braces For example
– minab = 144; {minimum age at first birth in months}
Recoding Variables
To recode variables, use the recode command
The following logic recodes women’s age into groupsrecode WM9 => agegrps;
15-19 => 1;
20-24 => 2;
=> 3;
endrecode;
Generating Error Messages
If the cluster number is invalid, the following code will display an error message
errmsg(0010);
Providing an Error Message
Error messages must have user-defined text to be effective
For the preceding example, one would add a line0010 cluster number invalid
To view the error message file– to do so, right click on the message tab while
editing a procedure’s logic
Error Message Parameters
The values of any variables listed after the error message number will be passed to the error message
Parameters are displayed in the error message using– %d for numeric values– %s for alphanumeric values
Creating the Application
Select file --> new Select object type data entry application Use file name: test Use folder: c:\mics\cspro\test Click next Click yes when prompted to use the test
form Click finish
Modifying the Application
Add logic to– check the household number is consistent
display message and data entry if not
– implement the region skip – check the date of interview is consistent
display message and require reentry if not
Compile and then save your application
Testing the Application
Click once on execute button on toolbar (traffic light)
Use nodata.dat datafile Enter a case