Advanced Architecture

World’s first 40 GHz handheld cable & antenna analyzer = widest frequency coverage

Highest Dynamic Range 110 dB typical

Highest corrected directivity = highest measurement accuracy

The most built-in Waveguide calibration support, 10 bands standard + 4 custom

Full 4 receiver VNA architecture

Will support full reversing S-Parameter measurements (Future VNA Option)

1 Hz frequency resolution across full range of operation, even up to 40 GHz

Slide 2

1 MHz to 8, 14, 20, 30, 40 GHz Cable and Antenna AnalyzerHighest RF Immunity (+17 dBm)

250 x 177 x 61 mm (10.0 x 7.1 x 2.4 in) <3.0 kg (6.6 lbs)

Page 3: Microwave Site  Master™  S820E

Advanced Architecture

Uses same sampler technology as our premium VectorStar™ VNA models

Instant On from standby mode

Highest RF Immunity +17 dBm

650 us/point measurement speed typical

New efficient circuitry delivers >4 hour battery life

Rugged K(m) connectors on units 20 GHz and above. Easily convert to N(f) type without compromising field ruggedness

Measure long, embedded transmission systems easily with USB Transmission Sensor and USB Extenders

Slide 3

Ruggedized K(m) test ports easily and robustly converted to N(f)

using 71693-R adapters stands up to rugged field use

Page 4: Microwave Site  Master™  S820E

Easy to use (Integrated Help)

Integrated Help function

System Info Tab displays instrument info, hardware info and software info in one convenient screen

FAQ Tab displays multiple frequently asked questions. Touch any of the desired questions to reveal the answer. Some FAQ answers may include hyperlinks to the built-in User Guide for more detailed information

User Guide Tab provides easy access to the instrument’s full HTML based user guide. No longer need to carry a hardcopy with you in the field

Slide 4

Help screen illustrating multiple help selection tabs

Page 5: Microwave Site  Master™  S820E

Easy to use (Easy Guided Calibration)

Easy Guided Calibration

4 step Cal Setup allows you to select from a variety of calibration types, choose the calibration type that best suits your needs

Choose between Coaxial or Waveguide line type and following calibration steps will change accordingly

Select the DUT connector type, photos provide examples of what each connector typically looks like

Once DUT connector type is selected, the selection of built-in calibration kits is narrowed down to models that fit the chosen DUT type

Slide 5

S820E Guided Calibration simplifiescalibration process, minimizes errors

Page 6: Microwave Site  Master™  S820E

Easy to use (S820D-like Classic Mode)

S820D-like Classic Mode

Mimics the same basic GUI operation as the former S810D/S820D models

Supports 2-Port Cable Loss like the S8X0D series but uses extendable USB sensors instead of basic diode detectors

1-port measurements like the S8X0D models, no Smith Chart, no 1-port phase measurement helps to minimize confusion and reduce errors with new users

Switch to Advanced Mode when comfortable to gain access to more measurement types and more performance enhancing user control features like adjustable IFBW

Slide 6

820D-like Classic Mode GUISimilar flow of operation compared

to previous S8X0D models

Page 7: Microwave Site  Master™  S820E

Easy to use (All connectors conveniently located on top)

All connectors located on top

Allows instrument to be used while in protective softcase

No need to spend time looking for desired connector

Keeps sides clear for easy handling

Reduces risk of cabling getting caught or snagged on nearby items

Slide 7

1. RF Port 1 6. DC Power Input

2. RF Port 2 7. Two USB 2.0 Type A ports

3. BNC External Trigger Input 8. Ethernet Port 10/100 MB/s

4. BNC External Reference Input 9. 3.5 mm Aux Headphone Jack Output

5. USB Type Mini B

Page 8: Microwave Site  Master™  S820E

Versatile features and options (Advanced Mode)

Advanced Mode (Default)

Additional measurement types like Smith Chart, 1-Port Phase, Transmission (2 port) Transmission (Ext. Sensor)

Dual Display Format

Mix any 2 measurement types

Simultaneously measure RL/VSWR and 2-Port Cable loss using external sensor

Supports different calibration types for each display, EG:Upper trace has standard 1-port OSL calibration, lower trace has 2-Port external sensor transmission calibration

Slide 8

820E Advanced ModeDual Display

Page 9: Microwave Site  Master™  S820E

Versatile features and options (Advanced Mode Continued)

System Function Tool Bar

Provides one-touch access to common system functions like Preset, Save, Help, Screenshot, Mode Selector, Full Screen

User Defined Shortcuts

Quick one-touch access to six favorite user defined shortcuts. Recall favorite setups without having to open Menu screen or File menu

Additional Markers (8 vs 6) and additional marker functions

Slide 9

820E Advanced ModeSystem Function Tool Bar

And User Defined Shortcuts

Page 10: Microwave Site  Master™  S820E

Versatile features and options (High Accuracy Power Meter)

Measure True RMS power accurately using Anritsu MA series USB power sensors

As low as ±0.16 dB uncertainty

Supports Inline High Power Measurements with MA24105A

Easily configure upper/lower measurement limits and scale

Displays both dBm and Watts simultaneously

Choose which one you prefer as the main readout

Easily add offsets to correct for external loss/gain

Easily set relative measurements

Slide 10

820E-High Accuracy Power Meter

Page 11: Microwave Site  Master™  S820E

Versatile features and options (Standard Features)

3 Year Warranty (1 year on battery)

2-Port Transmission Measurements

2-Port Cable Loss Measurement (requires external USB Sensor)

High Accuracy Power Meter (requires external USB Sensor)

Ethernet 10/100 port

Remote Control/PC File Transfer

3 USB ports (2 Type A, 1 Type mini-B)

Remote Control/PC File transfer

Peripheral device support

Large Internal Memory

Internally store >2000 files

Sweeps, setups, screenshotsSlide 11

820E-0720 includes two 71693-R ruggedized adapters

as standard accessories

Page 12: Microwave Site  Master™  S820E

Versatile features and options (Standard Features)

Built-in GPS support (requires 2000-1723-R)

10 user selectable languages

Fast preview of stored sweeps

Large 800 x 600 8.4” Easy to read High Resolution TFT Touchscreen

Supports Daylight & Nighttime modes

Touch screen provides efficient GUI and ease of use, with or without gloves

Alphanumeric keyboard

EZ Name Quick Matrix for fast saving

Can lock touch screen and use cursor mode or USB mouse for instrument control

Slide 12

820E-0720 includes two 71693-R ruggedized adapters

as standard accessories

Page 13: Microwave Site  Master™  S820E

Versatile features and options (Standard Features)

Active Thermal Management

Allows for faster warmup

Provides superior measurement stability

Passes stringent MIL-PRF-28800F Section 4.5.6.3 Explosive Atmosphere Requirement

Increases MTBF and reliability

Hi Capacity Li-Ion field replaceable battery

Extend field operating time by adding a spare optional battery

Hot swappable when externally powered

S820E-0720 model comes standard with two 71693-R ruggedized K(f) to N(f) adapters

Slide 13

820E-0720 includes two 71693-R ruggedized adapters

as standard accessories

Page 14: Microwave Site  Master™  S820E

Versatile features and options (Standard Features)

easyTest™ Tools

Generate and share measurement script files among multiple users

Display images, work instructions, details

Allows multiple users to achieve consistent results with reduced errors

Saves valuable time in the field

Line Sweep Tools (LST) Software

Edit sweeps, rename, archive

Generate PDF or HTML reports

Convert RL/VSWR to DTF

Convert RL/VSWR to Smith Chart

Slide 14

820E-0720 includes two 71693-R ruggedized adapters

as standard accessories

Page 15: Microwave Site  Master™  S820E

New accessories supporting S820E (New calibration kits)

New series of high performance coaxial calibration OSL/TOSL kits

Specified across full instrument operating temperature range: -10°C to +55°C. This is an industry leading first

Newly developed and manufactured by Anritsu, not 3rd party OEM like most competitor’s offerings

Provides unbeatable performance up to 40 GHz.

K type (2.92mm) mechanically compatible with SMA and 3.5mm connectors

1-year recommended calibration cycle

Slide 15

OSLX50A-XX, TOSLX50A-XXHigh performance, full temperature

Coaxial Calibration Kits

Page 16: Microwave Site  Master™  S820E

New accessories supporting S820E (New calibration kits)

New series of high performance coaxial calibration OSL/TOSL kits

Male and Female Models with through component have equal electrical length

Each calibration kit comes with its own soft case pouch, and includes hardcopy of technical data sheet

Cal coefficients are built into S820E firmware, just select the model and the analyzer takes care of the rest

Other Anritsu hand held analyzers will support new calibration kits via future firmware updates

Slide 16

OSLX50A-XX, TOSLX50A-XXHigh performance, full temperature

Coaxial Calibration Kits

Page 17: Microwave Site  Master™  S820E

New accessories supporting S820E (New Flexible Cables)

New series of 40 GHz high performance phase-stable test port extension cables

Available with Ruggedized K(f) connectors to mate securely to S820E test ports

Available with standard K type connectors

Can be used with Anritsu bench top VNA’s like VectorStar™ and Lightning™

Provides best performance/price ratio

Highly flexible for easy connection and usage

Available in 0.6m and 1.0m lengths

Slide 17

14 Series Phase-Stable Flexible Cables

Page 18: Microwave Site  Master™  S820E

New accessories supporting S820E (USB Transmission Sensor)

New SC8268 USB Transmission Sensor

Designed to optimize 2-Port cable loss measurement/2-Port Transmission (Ext. Sensor) measurement

Provides full coverage from 1 MHz to 40 GHz

Delivers most accurate results with lowest uncertainty

Slide 18

SC8268 USB Transmission Sensor

Page 19: Microwave Site  Master™  S820E

New accessories supporting S820E (USB Extender + Cat 5e)

New 2000-1717-R USB Extender

Extends USB Sensor up to 85m for measuring 2-Port cable loss on embedded cables, or on any DUT with ends located physically far from each other

Completely passive, requires no additional power source

Use with standard Cat 5e cable available everywhere (Cat 6 recommended for best results)

Use with 2100-28-R Cat 5e cable to extend up to 22.5m or purchase custom length from local cable supplier

Slide 19

S820E shown with 2000-1717-R USB Extender and 2100-28-R cable and SC8268 USB Transmission Sensor

Page 20: Microwave Site  Master™  S820E

Microwave Site Master™ S820E Cable/Antenna Analyzer

Slide 20

Advanced architecture, Easy to use, Versatile features and options