MICRO SWITCH™ Door SwitchesAC Series
Datasheet
2 sensing.honeywell.com
What makes our switches better? Available with Honeywell MICRO SWITCH™ V3, V7, SM, SE, or
BZ Series switches; there are no exposed contacts
Temperature ranges (-40 °C to 85 °C [-40 °F to 185 °F]) allow for reliable performance usage in harsh conditions
Many catalog listings have internal threaded actuators that allow customers to attach auxiliary plungers
Choice of switch actuation: two position momentary, two position momentary with a twist-latch feature, or a three position with push momentary and pull maintained action
MICRO SWITCH™ AC Series Door SwitchesWhen the application is more complex than a “stand alone” switch can provide, consider the MICRO SWITCH™ AC
Series Door Switch. The AC Series switch assembly monitors the position of a service door or panel whether “closed”
or “open”. The AC Series switches are a compact switch assembly designed for equipment applications ranging from
vending machine service doors or panels, monitoring doors for truck trailers, and military-related doors and/or panels.
When the equipment (door or panel, etc.) which is electrically interlocked through the AC Series switch is opened, the
action of the AC Series switch disconnects the electrical power. The AC Series switch can provide an electrical signal
to an annunciator circuit such as a light or horn indicating the door or panel is open. Another feature that is common
to most AC Series switch assemblies is a “pull-to-override” position which allows the service door to be open and yet
apply electrical power through the switch assembly. The “pull-to-override” switch position could be useful for trouble
shooting equipment as required.
AC Series switch assemblies are available with up to four switch elements which can provide discrete outputs as
required for control and/or indicator circuits. Select catalog listings are available with UL and CSA agency certification.
Where the application is military related, catalog listings are available with a military specification part number.
RIGHT SWITCH FOR THE RIGHT APPLICATIONPERFORMANCE • RELIABILITY
Right form factor combined with the right operating characteristics make a precise combination for door switch applications.
3sensing.honeywell.com
Features and Benefits Features and Benefits
RELIABLE PERFORMANCEThe switch automatically disconnects electrical power to equipment when service door, panel, or drawer is opened.
CHOICE OF SWITCH ACTUATIONChoose the standard switch assembly with one of three mechanical positions: push-momentary with a pull-to-override maintained position, the two position momentary switch assembly, or the two position switch assembly with a push-momentary and a push-and-turn-to-latch maintained position.
MOUNTING EASE The switch assembly is designed to be installed as a side mount or end mount for versatility.
WIDE ELECTRICAL RANGEWide range of current from less than 1 A to 21 A to interface with control and signal circuits.
AGENCY CERTIFICATIONS Select switch assemblies are certified to CSA and UL component recognition where agency certification is desired or required. When the application involves military requirements, several different styles of AC Series door switches are offered with military specifications.
CIRCUIT FLEXIBILITYSwitch assemblies are available with single throw or double throw action with up to four poles to provide control circuits and optional signal circuits as required.
TERMINATION OPTIONSTwo different types of switch termination (screw or quick connect blades) are available to meet machine design requirements.
Tough answer for tough door interlock needs
Enhanced switch offerings
4 sensing.honeywell.com
VENDING MACHINESIndicates front panel of vending machine is closed
HVAC EQUIPMENTServes as interlock for one or more service panels
APPLIANCESEquipped as interlock for service panels or access panels
COMMUNICATION EQUIPMENTProvides interlocking capability for service or access panels
BUSINESS EQUIPMENTProvides interlocking capability for service or access panels
TRUCK TRAILER OR SEMI-TRUCK TRAILER DOORSIndicates the door is closed and/or latched
COMMERCIAL DOORS AND GATESMonitors the door or gate is open or closed
MILITARY EQUIPMENTServes as a cabinet and service panel interlock for land-based electrical/electronic equipment
Potential Applications
5sensing.honeywell.com
MICRO SWITCH™ Door Switches
Table 1. Specifications • Metal Plunger
Catalog Listing
Figure No.
DescriptionSwitch Type
Elec. Rat-ing
Plunger ActionF.P.
max. mm [in.]
O.P. min.
mm [in.]
D.P. max.
mm [in.]
1AC2 1SPDT (1), screw
terminals, threaded plunger
BZ A3 position,
push-momentary, pull-maintained
11,1 [0.438]
6,35 [0.25]
3,17 [0.125]
2AC59 (MS16106-1)
3SPDT (1), screw
terminals, threaded plunger
V3 E3 position,
push-momentary, pull-maintained
9,53 [0,375]
5,16 [0.203]
3,17 [0.125]
2AC6 2SPDT (1), screw
terminals, threaded plunger
V3 C3 position,
push-momentary, pull-maintained
9,53 [0,375]
5,16 [0.203]
3,17 [0.125]
8AC1 6SPDT (4), solder
terminalsSM B
3 position, push-momentary, pull-maintained
9,53 [0,375]
5,16 [0.203]
3,17 [0.125]
13AC1 8SPDT (1), screw
terminals, threaded plunger
V3 C
2 position (special), push-
momentary, push & twist maintained
15,9 [0.625]
12,3 [0.485]
6,68 [0.263]
17AC1-T 9SPDT (1), solder
terminalsSM B
3 position, push-momentary, pull-maintained
9,53 [0,375]
5,59 [0.22]
4,45 [0.175]
Table 2. Electrical Ratings (in amperes)
Rating Code
Electrical Rating
A 15 A, 125, 250, or 480 Vac; 1/2 A, 125 Vdc; 1/4 A, 250 Vdc
B5 A, 125 or 250 Vac
30 Vdc ind.: 3 A (sea level) and 2.5 A (50,000 ft)30 Vdc res: 5 A (sea level and 50,000 ft); max. in-rush 24 A
C15 A, 125 or 250 Vac; 5 A, 125 Vac “L”; 1/2 A, 125 Vdc;
1/4 A, 250 Vdc; 1/2 hp, 125 or 250 Vac
D 21 A, 1 hp 125, 250, 277 Vac; 2 hp 250, 277 Vac
E
10 A res. and ind. (sea level), 28 Vdc and 125 Vac10 A res. (50,000 ft), 28 Vdc and 125 Vac
10 A ind. (50,000 ft), 125 Vac6 A ind. (50,000 ft), 28 Vdc
F 5 A, 125, 250, 277 Vac 1/10 hp, 250 Vac
F.P. • Free PositionO.P. • Operating Position
D.P. • Depressed Position
6 sensing.honeywell.com
AC Series
Table 3. Specifications • Plastic Plunger
Catalog Listing
Figure No.
DescriptionSwitch Type
Elec. Rat-ing
Plunger ActionF.P.
max. mm [in.]
O.P. min.
mm [in.]
D.P. max.
mm [in.]
8AC9 (MS16106-3)
7SPDT (4), solder
terminals, threaded plunger
SM B3 position,
push-momentary, pull-maintained
9,52 [0.375]
5,15 [0.203]
3,17 [0.125]
22AC1 10SPDT (1), screw
terminalsV3 C
3 position, push-momentary, pull-maintained
9,52 [0.375]
5,15 [0.203]
3,17 [0.125]
22AC2 11SPDT (1), screw
terminals, threaded plunger
V3 C3 position,
push-momentary, pull-maintained
9,52 [0.375]
5,15 [0.203]
3,17 [0.125]
22AC2-UL 12SPDT (1), screw
terminals, threaded plunger
V3 C3 position,
push-momentary, pull-maintained
9,52 [0.375]
5,15 [0.203]
3,17 [0.125]
23AC2 13SPDT (1), screw
terminals, threaded plunger
V3 C3 position,
push-momentary, pull-maintained
9,52 [0.375]
5,15 [0.203]
3,17 [0.125]
23AC81 14SPDT (1), quick
connect terminals, threaded plunger
V7 F2 position,
push-momentary9,52
[0.375]5,15
[0.203]3,17
[0.125]
24AC1 15SPDT (2), screw
terminalsV3 C
3 position, push-momentary, pull-maintained
9,52 [0.375]
4,75 [0.187]
3,17 [0.125]
4AC54 (MS16106-2)
4SPDT (2), screw
terminals, threaded plunger
V3 E
3 position, push-momentary
(1 sw.), pull-maintained (both
switches)
9,52 [0.375]
4,75 [0.187]
3,17 [0.125]
4AC55 (MS16106-5)
5SPDT (2), screw
terminals, threaded plunger
V3 E3 position,
push-momentary, pull-maintained
9,52 [0.375]
4,75 [0.187]
3,17 [0.125]
423AC2-E9 16SPDT (1), quick-
connect terminals, threaded plunger
V7 D3 position,
push-momentary, pull-maintained
9,52 [0.375]
5,15 [0.203]
3,17 [0.125]
F.P. • Free PositionO.P. • Operating Position
D.P. • Depressed Position
7sensing.honeywell.com
MICRO SWITCH™ Door Switches
GENERAL DIMENSIONSFigure 1. MICRO SWITCH™ 1AC2
19,44 mm [0.766 in]
8-32 NC 2B Thread0.75 in min. depth
10,5 mm [0.415 in]
35,05 mm [1.38 in]
23,35 mm [0.92 in]
6,75 mm ref [0.266 in ref]
Flexible insulatorCommon terminal
6-32 NC thread (2)
11,09 mm[0.437 in]
11,09 mm[0.437 in]
6,35 mm[0.25 in]
Ø 6,35 mm [Ø 0.25 in]
5,54 mm [0.218 in]
78,49 mm [3.09 in]
11,12 mm [0.438 in] max. free position
6,35 mm [0.25 in] min. operating position
3,17 mm [0.125 in] max. depressed position
57,15 mm [2.25 in]7,87 mm[0.31 in]25,4 mm [1.0 in]
17,06 mm[0.672 in]
Positive overtravel stop is provided on rod under spring
Ø 6,35 mm [Ø 0.25 in]
Ø 4,75 mm[Ø 0.187 in]
6-32 NC thread (2)
6-32 NC x 0.812 in ref.round head machine screw and lockwasher (2)
Normally open terminal
Normally closed terminal
6-32 NC x 0.218 in ref.binder head terminal screw and cupwasher (3)
9,6 mm[0.38 in]
19,8 mm[0.78 in]
20,3 mm[0.81 in]
Figure 2. MICRO SWITCH™ 2AC6
Ø 6,35 mm max. [Ø 0.25 in max.]
Flexible insulator
9,52 mm [0.375 in] max. free position
3,17 mm [0.125 in] max. depressed position
47,7 mm[1.88 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
6-32 UNC-2B Thread X
0.375 min.
Positive overtravel stop is provided on rod
under spring
V3-13 basic switch
6,35 mm[0.25 in]
31,0 mm[1.22 in]
4,8 mm[0.19 in]
2,79 mm [0.11 in]
Ø 4,75 mm[Ø 0.185 in]
5,53 mm [0.218 in]
2X 6-32 UNC Thread
6,73 mm ±0,25 mm[0.265 in ±0.01 in]
40,4 mm[1.594 in]
12,7 mm[0.50 in]
6,76 mm[0.266 in]
2X 6-32 UNC Thread
5,15 mm [0.203 in] min. operating position
Ø 6,35 mm max. [Ø 0.25 in max.]
13,2 mm ±0,76 mm [0.52 in ±0.03 in]
33,0 mm[1.30 in]
10,3 mm ±0,25 mm[0.406 in ±0.01 in]
3X 4-40 NC x 0.125 in round head terminal screws and lockwashers
4,54 mm ±0,25 mm[0.179 in ±0.01 in]
20,61 mm[0.812 in]
Figure 3. MICRO SWITCH™ 2AC59
Ø 6,35 mm max. [Ø 0.25 in max.]
Flexible insulator
9,52 mm [0.375 in] max. free position
3,17 mm [0.125 in] max. depressed position
47,7 mm[1.88 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
6-32 UNC-2B Thread X
0.375 min.
Positive overtravel stop is provided on rod
under spring
V3-1001 basic switch
6,35 mm[0.25 in]
31,0 mm[1.22 in]
4,8 mm[0.19 in]
2,79 mm [0.11 in]
Ø 4,75 mm[Ø 0.187 in]
5,54 mm [0.218 in]
Rivets flush orunderflush
2X 6-32 UNC Thread
6,73 mm ±0,25 mm[0.265 in ±0.01 in]
40,4 mm[1.594 in]
12,7 mm[0.50 in]
6,7 mm[0.266 in]
2X 6-32 UNC Thread
5,15 mm [0.203 in] min. operating position
Ø 6,35 mm max. [Ø 0.25 in max.]
13,2 mm ±0,76 mm [0.52 in ±0.03 in]
33,0 mm[1.30 in]
10,3 mm ±0,25 mm[0.406 in ±0.01 in]
3X 4-40 NC x 0.125 in round head terminal screws and lockwashers
4,54 mm ±0,25 mm[0.179 in ±0.01 in]
20,61 mm[0.812 in]
8 sensing.honeywell.com
AC Series
Figure 4. MICRO SWITCH™ 4AC54
Figure 5. MICRO SWITCH™ 4AC55
Figure 6. MICRO SWITCH™ 8AC1
Hole in bracket
3,5 mm [0.14 in]
Ø 6,35 mm max. [Ø 0.25 in max.]
2X flexible insulators
9,52 mm [0.375 in] max. free position
4,77 mm [0.188 in] max. pretravel
3,17 mm [0.125 in] max. depressed position
47,77 mm[1.88 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
6-32 UNC-2B Thread X
0.375 min.
Positive overtravel stop is provided on rod
under spring
6X 4-40 NC x 0.125 in round head terminal screws and lockwashers
2X V3-1001 basic switch
Ø 6,35 mm[Ø 0.25 in]
31,0 mm[1.22 in]
4,8 mm [0.19 in]
2,79 mm [0.11 in]
3,18 mm[0.145 in]
2X 6-32 UNC Thread
5,53 mm [0.218 in]
Rivets flush orunderflush
2X 6-32 UNC Thread
46,0 mm ±0,25 mm[1.812 in ±0.01 in]
4,54 mm ±0,25 mm[0.179 in ±0.01 in] 20,61 mm
[0.812 in]
40,4 mm[1.594 in]
11,07 mm ±0,25 mm[0.436 in ±0.01 in]
6,73 mm ±0,25 mm[0.265 in ±0.01 in]
13,2 mm [0.52 in]
6,75 mm [0.266 in]
6,75 mm [0.266 in]
53,05 mm[2.09 in]
23,0 mm[0.906 in]
Hole in bracket
3,5 mm [0.14 in]
Ø 6,35 mm max. [Ø 0.25 in max.]
2X flexible insulators
9,52 mm [0.375 in] max. free position
4,78 mm [0.188 in] max. pretravel
3,17 mm [0.125 in] max. depressed position
47,7 mm[1.88 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
6-32 UNC-2B Thread X
0.375 min.
Positive overtravel stop is provided on rod
under spring
6X 4-40 NC x 0.125 in round head terminal screws and lockwashers
2X V3-1001 basic switch
Ø 6,35 mm[Ø 0.25 in]
31,0 mm[1.22 in]
4,826 mm [0.19 in]
2,79 mm [0.11 in]
Ø 4,75 mm[Ø 0.187 in]
2X 6-32 UNC Thread
5,53 mm [0.218 in]
Rivets flush orunderflush
2X 6-32 UNC Thread
46,0 mm ±0,25 mm[1.812 in ±0.01 in]
4,54 mm ±0,25 mm[0.179 in ±0.01 in] 20,61 mm
[0.812 in]
40,4 mm[1.594 in]
11,07 mm ±0,25 mm[0.436 in ±0.01 in]
6,73 mm ±0,25 mm[0.265 in ±0.01 in]
13,2 mm [0.52 in]
90° ±10° X SUR Ø 4,1 mm [Ø 0.16 in]6,75 mm [0.266 in]
6,75 mm [0.266 in]
53,05 mm[2.09 in]
23,0 mm[0.906 in]
Positive overtravel stop is provided on rodunder spring
Ø 6,35 mm max. [Ø 0.25 in max.]
Ø 4,75 mm max. [Ø 0.188 in max.]
Flexible insulators
20,62 mm [0.812 in]
47,7 mm [1.88 in]
3,17 mm [0.125 in] max. depressed position
5,15 mm [0.203 in] min. operating position
9,52 mm [0.375 in] max. free position
2,8 mm [0.11 in]
4,82 mm [0.19 in]30,9 mm [1.22 in]
1,47 mm [0.058 in] dia. hole in terminals
(2) 6-32 UNC thread
(2) 6-32 UNC thread
Ø 6,35 mm max. [Ø 0.25 in max.]
11,09 mm [0.437 in]
5,53 mm [0.218 in]
6-32
UNC
-2B
thre
ad0.
375
min
. dep
th
hole inbracket
CL
7,55 mm [0.30 in]
40,35 mm [1.59 in]
25,4 mm [1.0 in]
12,7 mm [0.5 in]
8,63 mm [0.34 in]
15,0 mm [0.59 in]
16,5 mm [0.65 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operated position until reset for automatic return
by next full-stroke “push” operation
4,54 mm[0.179 in]
1SM1 basic switch (4)
9sensing.honeywell.com
MICRO SWITCH™ Door Switches
Figure 7. MICRO SWITCH™ 8AC9
Figure 8. MICRO SWITCH™ 13AC1
Figure 9. MICRO SWITCH™ 17AC1-T
Positive overtravel stop is provided on rodunder spring
Ø 6,35 mm max. [Ø 0.25 in max.]
Ø 4,77 mm max. [Ø 0.188 in max.]
Flexible insulators
20,61 mm [0.812 in]
47,7 mm [1.88 in]
3,17 mm [0.125 in] max. depressed position
5,15 mm [0.203 in] min. operating position
9,52 mm [0.375 in] max. free position
2,8 mm [0.11 in]
4,83 mm [0.19 in]31,0 mm [1.22 in]
0.058 dia. hole interminals
(2) 6-32 UNC thread
(2) 6-32 UNC thread
Ø 6,35 mm max. [Ø 0.25 in max.]
11,09 mm [0.437 in]
5,53 mm [0.218 in]
6-32
UNC
-2B
thre
ad0.
375
min
. dep
th
hole inbracket
CL
7,62 mm [0.30 in]
40,3 mm [1.59 in]
25,4 mm [1.0 in]
12,7 mm [0.5 in]
8,6 mm [0.34 in]
15,0 mm [0.59 in]
16,5 mm [0.65 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operated position until reset for automatic return
by next full-stroke “push” operation
4,54 mm[0.179 in]
11SM357-T basic switch (4)
6,35 mm[0.25 in]
Ø 6,35 mm [Ø 0.25 in]
before knurl
45,97 mm [1.81 in]
12,7 mm[0.50 in]
Flexible insulator
3X 4-40 NC x 0.125 in round head terminal screws and lockwashers
Positive overtravel stop is provided on rod under spring
15,9 mm [0.625 in] max. free position
12,3 mm [0.485 in] min. operating position
6,68 mm [0.263 in] max. depressed position
48,2 mm[1.90 in]
Push to operate-returns automaticallyto position shown.
Push and turn (approximately 60° clockwise)to latch. Remains in operated position
until reset for automatic returnby next push operation
2X 6-32 UNC Thread V3-13 basic switch
38,07 mm ±0,25 mm[1.50 in ±0.01 in]
Rivets flush orunderflush 3X 6-32 UNC Thread
Hole inbracket
6-32 UNC-2B Thread X
0.375 min.
Place label on this surface
12,05 mm [0.475 in] max. latched position
8,25 mm [0.325 in] min. unlatch position
15,2 mm[0.6 in]
Ø 4,75 mm[Ø 0.187 in]
7,9 mm[0.31 in]
40,4 mm[1.592 in]
5,1 mm[0.20 in]
4,1 mm[0.16 in]
8,68 mm[0.342 in]
19,0 mm ±0,25 mm[0.75 in ±0.01 in]
30,0 mm [1.182 in]
Ø 2,79 mm [Ø 0.11 in]
Ø 1,27 mm [Ø 0.05 in]
9,01 mm max.[0.355 in max.]
1,47mm [0.058 in]
4,8 mm [0.19 in]
4,8 mm [0.19 in]
8,88 mm ±0,51 mm[0.350 in ±0.02 in]
Flexible insulator
Positive overtravel stop is provided on plungerunder spring
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operated position until next full-stroke by plunger
9,53 mm [0.375 in] max. free position
5,58 mm [0.220 in] min. operating position
4,44 mm [0.175 in] max. depressed position
38,8 mm ±0,76 mm [1.53 in ±0.03 in]
5,84 mm ±0,25 mm[0.230 in ±0.01 in]
11,09 mm [0.437 in]
6,6 mm[0.26 in]
9,91 mm[0.39 in] 14,67 mm
[0.578 in]
4-48 UNF-28 (3)
6,6 mm[0.26 in]
8,6 mm[0.34 in]
24,9 mm [0.98 in]
28 mm [1.1 in]
11SM1-T basic switch (1)
10 sensing.honeywell.com
AC Series
Figure 10. MICRO SWITCH™ 22AC1
Figure 11. MICRO SWITCH™ 22AC2
Figure 12. MICRO SWITCH™ 22AC2-UL
6,35 mm[0.25 in]
Ø 6,35 mm [Ø 0.25 in]
6,75 mm[0.266 in]
33,0 mm [1.30 in]
10,31 mm ±0,25 mm[0.406 in ±0.01 in]
12,7 mm[0.50 in]
2X 6-32 UNC Thread
Ø 6,35 mm max. [Ø 0.25 in max.]
Flexible insulator3X 4-40 NC x 0.125 in round headterminal screw and lockwasher
Positive overtravel stop isprovided on rod under spring
Ø 4,52 mm [Ø 0.178 in]
2,79 mm ±0,76 mm[0.11 in ±0.03 in]
40,4 mm [1.59 in]
9,52 mm [0.375 in] max. free position
5,15 mm [0.203 in] min. operating position
3,17 mm [0.125 in] max. depressed position
47,7 mm [1.88 in]31 mm[1.22 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
20,61 mm [0.812 in]
4,8 mm [0.19 in]
2X 6-32 UNC Thread
V3-13 basic switch
13,2 mm ±0,76 mm[0.52 in ±0.03 in]
6,73 mm ±0,25 mm[0.265 in ±0.01 in]
5,53 mm ±0,25 mm[0.218 in ±0.01 in]
Rivets flush orunderflush
4,54 mm ±0,25 mm[0.179 in ±0.01 in]
6,35 mm [0.25 in]
Hole in bracketØ 6,35 mm [Ø 0.25 in]
13,2 mm[0.52 in]
33,0 mm [1.30 in]
10,3 mm ±0,25 mm[0.406 in ±0.01 in]
12,7 mm[0.50 in] 4X 6-32 UNC Thread
4-40 UNC Thread0.375 in min.
Ø 6,35 mm max. [Ø 0.25 in max.]
Flexible insulator
3X 4-40 NC x 0.125 in round headterminal screw and lockwasher
Positive overtravel stop isprovided on rod under spring
Ø 4,69 mm [Ø 0.185 in]
2,79 mm ±0,76 mm[0.11 in ±0.03 in]
7,87 mm[0.31 in]
40,44 mm [1.59 in]
9,52 mm [0.375 in] max. free position5,15 mm [0.203 in] min. op. position3,17 mm [0.125 in] max. depr. pos.
47,75 mm [1.88 in]
31,0 mm [1.22 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
6,35 mm[0.25 in]
Place label onthis surface
20,62 mm [0.812 in]
4,54 mm ±0,25 mm[0.179 in ±0.01 in]
4,5 mm [0.17 in]
Ø 6,35 mm [Ø 0.25 in]
13,21 mm ±0,76 mm[0.52 in ±0.03 in]
33,0 mm [1.30 in]
10,31 mm ±0,25 mm[0.406 in ±0.01 in]
12,7 mm[0.50 in]
2X 6-32 UNC Thread
4-40 UNC-2B ThreadX 0.375 in min. Ø 6,35 mm max.
[Ø 0.25 in max.]
4X Flexible insulator
Positive overtravel stop isprovided on rod under spring
Ø 4,52 mm [Ø 0.178 in]
2,79 mm ±0,76 mm[0.11 in ±0.03 in]
50,8 mm [2.00 in]
9,53 mm [0.375 in] max. free position
5,16 mm [0.203 in] min. op. position
3,175 mm [0.125 in] max. depr. pos.
47,75 mm [1.88 in]
30,98 mm [1.22 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
6,35 mm[0.25 in]
20,62 mm[0.812 in]
4,5 mm ±0,25 mm[0.179 in ±0.01 in]
4,83 mm [0.19 in]
6,73 mm ±0,25 mm[0.265 in ±0.01 in]
Rivets flush or underflush
8,51 mm[0.335 in]
3X 4-40 UNC X 0.125 inround head terminal screwsand lockwashers
2X 6-32 UNC Thread
5,54 mm ±0,25 mm[0.218 in ±0.01 in]
V3-3013 Basic switch
11sensing.honeywell.com
MICRO SWITCH™ Door Switches
Figure 13. MICRO SWITCH™ 23AC2
Figure 14. MICRO SWITCH™ 23AC81
Figure 15. MICRO SWITCH™ 24AC1
2X 6-32 UNC Thread6,35 mm [0.25 in]
Hole in bracket
Ø 6,35 mm [Ø 0.25 in]
13,2 mm[0.52 in]
45,9 mm [1.81 in]
38,07 mm[1.5 in]
19,03 mm[0.75 in]
8,70 mm[0.343 in]
4,06 mm [0.16 in]
3X 6-32 NC Thread
4-40 UNC Thread9,52 mm [0.375 in] min.
Ø 6,35 mm max. [Ø 0.25 in max.]
Flexible insulator
3X 4-40 NC x 0.125 in round headterminal screw and lockwasher
Positive overtravel stop isprovided on rod under spring
Ø 4,75 mm [Ø 0.186 in]
2,79 mm ±0,76 mm[0.11 in ±0.03 in]
7,9 mm [0.31 in]
40,4 mm [1.59 in]
9,52 mm [0.375 in] max. free position
5,15 mm [0.203 in] min. operating position
3,17 mm [0.125 in] max. depressed position
47,7 mm [1.88 in]33,8 mm [1.33 in]
15,2 mm [0.6 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
1.500
CL
2X 6-32 UNC Thread6,35 mm [0.25 in]
Hole in bracket
Ø 6,35 mm [Ø 0.25 in]
13,2 mm[0.52 in]
45,9 mm [1.81 in] 38,1 mm
[1.5 in]
19,03 mm[0.75 in]
8,70 mm[0.343 in]
4,06 mm [0.16 in]
3X 6-32 NC Thread
4-40 UNC Thread9,52 mm [0.375 in] min.
Ø 6,35 mm max. [Ø 0.25 in max.]
Flexible insulator
3X 4,75 mm W x 0.51 mm T[0.187 in W x 0.020 in T]quick connect terminals
Positive overtravel stop isprovided on rod under spring
Ø 4,75 mm [Ø 0.186 in]
7,9 mm [0.31 in]
40,4 mm [1.59 in]
9,52 mm [0.375 in] max. free position5,15 mm [0.203 in] min. operating position3,17 mm [0.125 in] max. depressed position
42,67 mm [1.68 in]
30,99 mm [1.22 in]12,7 mm
[0.5 in]
Push to operate-returns automaticallyto position shown.
Hole in bracket
3,56 mm [0.14 in]
Ø 6,35 mm max. [Ø 0.25 in max.]
Flexible insulators
9,52 mm [0.375 in] max. free position
4,77 mm [0.188 in] max. pretravel
3,17 mm [0.125 in] max. depressed position
47,7 mm[1.88 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
Positive overtravel stop is provided on rod
under spring
6X 4-40 NC x 0.125 in round head terminal screws and lockwashers
2X V3-13 basic switch
Ø 6,35 mm[Ø 0.25 in]
31 mm[1.22 in]
4,826 mm [0.19 in]
2,79 mm [0.11 in]
4,72 mm[0.186 in]
2X 6-32 UNC Thread
5,53 mm [0.218 in]
Rivets flush orunderflush
2X 6-32 UNC Thread
46,0 mm[1.812 in]
4,54 mm ±0,25 mm[0.179 in ±0.01 in] 20,61 mm
[0.812 in]
40,4 mm[1.594 in]
11,07 mm ±0,25 mm[0.436 in ±0.01 in]
7,03 mm ±0,25 mm[0.277 in ±0.01 in]
13,2 mm [0.52 in]
6,75 mm [0.266 in]
6,75 mm [0.266 in]
53,05 mm[2.09 in]
23,0 mm[0.906 in]
12 sensing.honeywell.com
AC Series
Figure 16. MICRO SWITCH™ 423AC2-E9
CL
3X 6-32 UNC Thread
2X 6-32 UNC Thread6,35 mm [0.25 in]
Hole in bracket
Ø 6,35 mm [Ø 0.25 in]
±0,76 mm [±0.03 in]
45,9 mm [1.81 in]
38,1 mm ±0,25 mm[1.5 in ±0.01 in]
19,05 mm[0.75 in]
8,71 mm[0.343 in]
4,1 mm [0.16 in]
3X 6-32 UNC Thread
4-40 UNC Thread0.375 in min.
Ø 6,35 mm max. [Ø 0.25 in max.]
Flexible insulator
3X 0.25 in wide x 0.032 in thickquick connect terminal
Positive overtravel stop isprovided on rod under spring
Ø 4,72 mm [Ø 0.186 in]
2,79 mm ±0,76 mm[0.11 in ±0.03 in]
7,87 mm [0.31 in]
44,7 mm ±0,76 mm[1.761 in ±0.03 in]
40,4 mm [1.59 in]
9,52 mm [0.375 in] max. free position
5,15 mm [0.203 in] min. operating position3,17 mm [0.125 in] max. depressed position
47,7 mm [1.88 in]33,76 mm [1.33 in]
15,2 mm [0.6 in]
Push to operate-returns automaticallyto position shown.
Pull to operate-remains in operatedposition until reset for automatic return
by next full-stroke “push” operation
13sensing.honeywell.com
MICRO SWITCH™ Door Switches
ADDITIONAL INFORMATIONThe following associated literature is available on the Honeywell web site at sensing.honeywell.com:• Product installation instructions
• Product range guide
• Product application-specific information
– Technical note: Applying precision switches
WARNINGPERSONAL INJURYDO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION• The information presented in this product sheet is for
reference only. Do not use this document as a product installation guide.
• Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
WARRANTY/REMEDYHoneywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particu-lar purpose. In no event shall Honeywell be liable for conse-quential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
13AC117AC18-T17AC1-T17AC28-H5817AC34-T1AC11AC21AC2422AC122AC1-D822AC222AC2-D822AC2-UL23AC223AC8023AC80-UL23AC8123AC8224AC124AC2224AC27-D92AC1092AC110
This datasheet supports the following MICRO SWITCH™
AC Series Door Switches
2AC192AC592AC62AC97-D83AC1203AC493AC53AC63AC683AC6-D8423AC2-E94AC544AC554AC604AC794AC87AC127AC78AC18AC278AC29-UL8AC9
004981-1-EN IL50 GLO May 2014Copyright © 2014 Honeywell International Inc. All rights reserved.
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
Find out moreHoneywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office.
To learn more about Honeywell’s
sensing and control products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to