20
© 2018 OTT HydroMet 1 © 2018 OTT HydroMet 1 Stefan Siedschlag Product Manager Hydrology / Discharge MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP Add text

MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 1© 2018 OTT HydroMet 1

Stefan Siedschlag – Product Manager Hydrology / Discharge

MF PRO MEASUREMENT PROCEDURE FW 2.0

STEP BY STEP

Add text

Page 2: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 2© 2018 OTT HydroMet 2

AGENDA

OTT MF pro – Measurement Procedure

1. Site Selection

2. Site Demarcation

3. Instrument Assembly

4. Meter Setup

5. Measurement Setup

6. Start Measurement – Basics

7. Start Measurement – Edge Position

8. Conduct Measurements at Stations

9. End Measurement – Edge Position

10. End Measurement – Review Results

11. End Measurement – Save Data

12. Data Download and Review

OTT MF pro – Step by Step user guidance for FW 2.0

Page 3: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 3© 2018 OTT HydroMet 3

SITE SELECTION

OTT MF pro – Step by Step user guidance for FW 2.0

90°

• Select a site with straight reach and uniform cross-section.

• The flow should be parallel to the bank and at a right angle to the measurement section.

• Take care for stable river bed and banks.

• Avoid sites with reverse flow, dead water zones or swirls.

• The cross-section should be unobstructed by obstacles.

Page 4: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 4© 2018 OTT HydroMet 4

SITE DEMARCATION

left bank

righ

t b

ank

• Define a reference point at the bank

• Divide the cross-section in a certain number of stations (verticals).

• Consider the number of stations according to ISO 748 *)

• A cross-section survey in advance is recommended and should be used for locating stations where the bottom elevation changes significantly.

• Use a tape for measuring the distances of bank and station positions.

• Mark left edge, station positions and right edge clearly visible.

*) ISO 748:2007 Hydrometry – Measurement of liquid flow in open channels using current-meters or floats

left

right

direction of flow

reference point = 0

OTT MF pro – Step by Step user guidance for FW 2.0

Page 5: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 5© 2018 OTT HydroMet 5

INSTRUMENT ASSEMBLY

Prepare your instrument components:

1. 20 mm universal rod 2. Relocation device HERES3. MF pro sensor4. MF pro adapter for use with 20 mm universal

rod5. MF pro portable meter6. MF pro adjustable meter mount

1 2

3 4 5 6

OTT MF pro – Step by Step user guidance for FW 2.0

Page 6: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 6© 2018 OTT HydroMet 6

INSTRUMENT ASSEMBLY

1

2

3

4

5

6

7

820 mm rod

HERES

OTT MF pro – Step by Step user guidance for FW 2.0

Page 7: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 7© 2018 OTT HydroMet 7

METER SETUP

Setup time and date

Setup discharge calculationmethod

Setup measurement resolution

OTT MF pro – Step by Step user guidance for FW 2.0

Page 8: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 8© 2018 OTT HydroMet 8

Prior measurement start please check for the correct setting of the FPA time (Fixed Period Average) for velocity measurements (menu <Setup>). The FPA time is recommended to be at least 30 s. Then select <Stream>.

START MEASUREMENT – BASICS

1 2 3 4 5

OTT MF pro – Step by Step user guidance for FW 2.0

Page 9: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 9© 2018 OTT HydroMet 9

START MEASUREMENT – EDGE POSITION

left bank

left bank

1

2

OTT MF pro – Step by Step user guidance for FW 2.0

Page 10: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 10© 2018 OTT HydroMet 10

START MEASUREMENT – EDGE POSITION

If the MF pro sensor is used with a rod which has a spike and the spike does not cave in the ground you’ll need to enter the offset value. For OTT 20 mm universal rods it is 0.035 m. The offset can be changed at each station.

3

OTT MF pro – Step by Step user guidance for FW 2.0

Page 11: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 11© 2018 OTT HydroMet 11

0,2

12

m

Please note:

For trapezoidal banks or natural river banks the depth at station 1 is zero. For vertical banks you‘ll need to measure the depth.

Station 1 Station 1

START MEASUREMENT – EDGE POSITION

The edge factor corresponds with the roughness of the bank (see manual).

4

OTT MF pro – Step by Step user guidance for FW 2.0

Page 12: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 12© 2018 OTT HydroMet 12

5 6

START MEASUREMENT – EDGE POSITION

If all settings for the edge position (station 1) are done select <Next> to move forward to station 2.

OTT MF pro – Step by Step user guidance for FW 2.0

Page 13: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 13© 2018 OTT HydroMet 13

CONDUCT MEASUREMENTS AT STATIONS

1 2 3

OTT MF pro – Step by Step user guidance for FW 2.0

Page 14: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 14© 2018 OTT HydroMet 14

Select an appropriate velocity method. Move the probe until the sensor depth proposal is met (green background). Select <Capture>, repeat this procedure for all points where appropriate. Check the velocity distribution (<Verify>. Return to the <Main> menu and select <Next> to move forward to the next station.

CONDUCT MEASUREMENTS AT STATIONS

4 5 6 7

8 9 10 11 12

OTT MF pro – Step by Step user guidance for FW 2.0

Page 15: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 15© 2018 OTT HydroMet 15

END MEASUREMENT – EDGE POSITION

righ

t b

ank

right bank

1 2 3 4

OTT MF pro – Step by Step user guidance for FW 2.0

Page 16: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 16© 2018 OTT HydroMet 16

END MEASUREMENT – REVIEW RESULTS

Each bar represents the measured depth at the station.

Each bar represents the percentage of measured discharge q per station related to the total Q.

Green = q ≤ 5%

Yellow = 5% < q ≤ 10%

Red = q > 10%

Each bar represents the mean velocity at the station.

OTT MF pro – Step by Step user guidance for FW 2.0

Page 17: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 17© 2018 OTT HydroMet 17

END MEASUREMENT – SAVE DATA

Finish your measurement by selecting <Save Data and Exit>. The proposal for the file name is taken form the entered name for the stream profile.

OTT MF pro – Step by Step user guidance for FW 2.0

Page 18: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 18© 2018 OTT HydroMet 18

DATA DOWNLOAD AND REVIEW

*.TSV output file

1. Set the USB port to „Mass Storage“. 2. Connect the meter with the PC via USB cable3. Switch the meter on. 4. Download your measurement from the folder named “P”.

OTT MF pro – Step by Step user guidance for FW 2.0

Page 19: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 19© 2018 OTT HydroMet 19

DATA DOWNLOAD AND REVIEW

Open you measurement in Qreview Version 3.0.9.8 for data post-processing.

OTT MF pro – Step by Step user guidance for FW 2.0

Page 20: MF PRO MEASUREMENT PROCEDURE FW 2.0 STEP BY STEP · © 2018 OTT HydroMet 3 SITE SELECTION OTT MF pro –Step by Step user guidance for FW 2.0 90° • Select a site with straight

© 2018 OTT HydroMet 20© 2018 OTT HydroMet 20

Thank you for your attention!

Thank you for your attention!

OTT MF pro – Step by Step user guidance for FW 2.0