Methodology for Liquid Ultrasonic Flow Measurement within the Laminar to Turbulent Transitional Zone Dave Seiler Daniel Measurement and Control March 25, 2014
2
Heavy Oil Definition !! !!the API classifies heavy oil as crudes with a
gravity below 22.3° API !! !!although variously defined, the upper limit for
heavy oil is 22° API gravity with a minimum viscosity of 100 cp (centipoise).
!! Heavy oil deposits around the world share only one characteristic: they are challenging to produce.
!! The “easy” crude oil is becoming harder to find
2!
3
Traditional Measurement Technology – Displacement Meter
All Displacement Meters rely on a capillary seal for good performance
Dual Rotor
Measuring Chamber
Meter Housing
Rotor
Cam Inner Unit Housing
Static Liquid
Blade Path of Blades
Flowing Liquid
Sliding Vane
Bearings
Capillary Seal
4
Reynolds Number Affect on Displacement Meter
Minimum “slippage”
3!
5
Alternative Technologies
Helical Turbine Meter
Coriolis Meter Ultrasonic Meter
6
Ultrasonic Meters !! Industry acceptance of Liquid Ultrasonic is driving
technology growth !! Technology is well entrenched into custody
transfer type applications !! Manufacturers are continuing to invest and drive
for “ease of use” and improvements in measurement
!! Customers are applying the technology into more complex applications
4!
7
Transit Time USM – How It Works?
!! Measures transit times of ultrasonic pulses
!! Transducer locations placed for optimum measurement accuracy
!! Transducers act alternately as transmitter and receiver
Multipath Liquid USM
Multipath Liquid USM
4321
1
1382.03618.03618.01382.0 vvvv
vwVn
iiiaverage
!+!+!+!=
="=
AVQ average !=where Q = flow rate A = cross sectional area of the
Meter bore
Flow
8
Liquid Ultrasonic Meter High Viscosity Flow Measurement Challenge
•! Measurements are dependent on velocity profile •! Velocity profile is Reynolds number (Re) (i.e. flow regime)
dependent •! Turbulent: Re>5000 •! Laminar: Re<2000 •! Transitional 2000<Re<5000
•! Liquid ultrasonic flow meters perform the best in the turbulent regime
•! Measurement non-linearity increases rapidly as Re<104 in conventional flow measurement applications
5!
9
The Challenge !! Develop a transducer capable of transmitting a signal
through a high viscosity fluid
!! Accurately measure volume through all flow regimes including Transitional
Transducer Housing
Transducer Capsule
Transducer Retainer
10
Objective
Develop a methodology to measure high viscosity fluid flow rate using liquid ultrasonic meters with high accuracy required for custody transfer applications
6!
11
Typical Meter Run – API 5.8
12
Installations
Flow
Elbow Flow
Tee or Header
7!
13
Conventional Flow Measurement Error vs. Reynolds Number Curves
Turbulent Laminar Transition
Experimental Error
14
Conventional Flow Measurement Error vs. Reynolds Number Curves
Turbulent Laminar Transition
8!
15
Conventional Flow Measurement Error Curves
16
Conventional Flow Measurement Error Curves
9!
17
Potential Solutions
•! Correct meter error without changing the fluid flow velocity profile (electronic corrections in meter firmware)
•! Difficult to formulate algorithms across flow regimes and for different upstream piping configurations
•! Modify fluid flow velocity profile to one that can be accurately measured
•! Utilize special (custom) flow conditioners •! Employ a combination of both of the above for the entire
Reynolds number range
18
Proposed Piping Solutions
CPA Plate
3D
With large upstream pipe Without large upstream pipe
10!
19
Flow Development with an Upstream Diffuser
-! Velocity Profile "! Average Velocity along path
20
Flow Development with an Upstream Diffuser !! Re_1000_TRANS_VenturiC_3DHEAD_PORTS_
DivConv_POS_VelProfDev.avi !! Re_1985
TRANS_VenturiC_3DHEAD_PORTS_POS_VelProfDev.avi
!! Re_6150 Turb_VenturiC_3DHEAD_PORTS_POS_VelProfDev.avi
!! Re_6150_Turb_VenturiC_3DHEAD_PORTS_DivConv_POS_VelProfDev.avi
11!
21
!! High viscosity flow loop –! up to 1000cSt –! Temperature controlled –! 8” PD Master Meter –! 18” SVP
Daniel Test Loop - Houston
22
Performance Results - 8” Liquid Ultrasonic Meter with Proposed Piping
!! SVP proves the master meter !! Master proves the Liquid USM !! Master Meter re-proven
12!
23
Performance Results - 8” Liquid Ultrasonic Meter with Proposed Piping
24
Liquid Ultrasonic Flow Meter Performance for Different Viscous Fluids
13!
25
Performance of Different Size Meters
26
Summary
•! CFD provided additional insight to improve liquid ultrasonic flow meter performance with Gaussian quadrature integration with Chebyshev’s polynomials of second kind
•! Flow conditioning has a significant effect on 4 path liquid ultrasonic meter performance in low Reynolds number regions
•! Employing the proposed piping solutions can achieve the accuracy required for custody transfer within laminar to turbulent transitional zone
•! Utilization of flow conditioning upstream of a reducer provided approximately 80% less pressure drop compared to conventional bore matched flow conditioning
14!
27
“People who say it cannot be done should not interrupt those
who are doing it."
– George Bernard Shaw