Metal Buss Tape ReliabilityJason Hevelone, Nikesh Dhar, & Chris Richardson

March 1, 2012

Page 2: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 1

Why am I here?

-Tom Krause

Page 3: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 2

What exactly are metal buss tapes?

Typically used for interconnect within a thin-film module to route generated power to the junction box.Most were derived from EMI shielding tape products and have evolved over time to meet the durability needs of PV modules

Page 4: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 3

Buss Tape Technologies

PossibilitiesMetal foil with pressure-sensitive adhesive (PSA)Metal foil with epoxy adhesiveMetal foil with ultrasonic soldering / resistive weldingMetal foil with no adhesive (contract force alone)

VariationsEmbossed vs. smoothConductive vs. non-conductive adhesive

Make up and size distribution of conductive filler particlesInclusion of carbonBalance between adhesive and filler conduction vs. adhesion

Foil metallurgyWidth and thicknessAdhesive properties over temperature

Embossed Smooth

Page 5: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 4

Possible Reliability / Quality Concerns

Joint failureLoss of adequate tape adhesionArcing / fusing of conduction points

Current carrying capacity (ampacity)Tape itselfTape-to-back metalTape-to-tape joint

Arcing between tapes at junction box (spacings)

Shorting out adjacent cells (loss of power)

Metallurgical compatibility (galvanic corrosion)

Material CTE mismatches (Coefficient of Thermal Expansion)

Page 6: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 5

Process Variability

Roller pressureRoller durometerRoller wear outSpeed of tape applicationAdhesive wettingEmbossing depth controlConductive filler particle size & distributionUniformity of conductive filler particles in adhesiveAbility of tape vendors to monitor quality factors important for PV durabilitySlitting quality (coining, slitting tool wear, adhesive contamination, liners, etc)Tape batch variations and ability to detect good vs. bad (i.e. quality controls)Adhesive voids (i.e. trapped air pockets)Cleanliness of surface in contact with tapeTopology of surface in contact with tape

SmoothHeavily emboss

Medium emboss

Over emboss creating voids in adhesive

Page 7: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 6

Catastrophic failures experiences and your reactions to them

Film damage at burned conduction points

T-­‐Joint failures

Buss damage along length of collector buss

Buss damage as seen from the backside of the module

Poor solder joint wetting

Page 8: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 7

How best to accelerate buss tape failure mechanisms?

Stress Test Catch Buss Failure Mechanism?

Reason

Temperature Cycling Test: UL1703, 35(-­‐40C to +90C, 200 cycles, small fwd bias current to assure continuity during cycle) Occasionally

Failure mechanism requires both thermal fatigue and high current flow during cycles

High Temperature Bake(90C, 1000 hours, with and without high fwd bias current) No

Failure mechanism requires both thermal fatigue and high current flow

Reverse Current Overload: UL1703, 28(Fwd bias at 130% of fuse rating, 1 hour)

Occasionally

Failure mechanism requires thermal fatigue. Much higher current flow (>200-­‐500% of Isc) and longer stress duration increase chances of detecting failure mechanism. Hard to correlate to product lifetimes.

Damp Heat: IEC61646, 10.13(85C, 85% R.H., 1000 hours, unbiased) No

Failure mechanism requires both thermal fatigue and high current flow

Humidity Freeze: UL1703, 36(-­‐40C to +85C/85%R.H., 10 cycles, small fwd bias current to assure continuity during cycle)

No

Failure mechanism requires both thermal fatigue and high current flow during cycles. Ten cycles is insufficient to provide enough thermal fatigue.

High Current Stress Temperature Cycling(-­‐40C to +90C, test to failure, high fwd bias current, >2x-­‐4x Isc) Yes

Failure mechanism requires both thermal fatigue and high current flow during cycles. Must test to failure in order to get to tape wear-­‐out.

Existing UL/IEC test methods are often insufficient to catch buss tape durability failure mechanisms

Page 9: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 8

Temperature Cycle with varied T, constant DC currentLooking at effects of two different T stress levels

ReliaSoft ALTA 7 -­ www.ReliaSoft.com

Acceleration Factor vs Stress

Std=0.6955;; K=2.5327E-­12;; n=4.6238T emperature Delta (degrees C)

Acceleration Factor

0 15030 60 90 1200

900

180

360

540

720

Acceleration Factor

Data 1Inverse Power LawLognormal30F=45 | S=1AF Line

ReliaSoft ALTA 7 -­ www.ReliaSoft.com

Probability -­ Lognormal

Std=0.6955;; K=2.5327E-­12;; n=4.6238Cycles

Unreliability

1 20000010 100 1000 100001

5

10

50

99 Probability

Data 1Inverse Power LawLognormal110 delta TF=26 | S=1Stress Level PointsStress Level Line

130 delta TF=19 | S=0Stress Level PointsStress Level Line

Use Level Line

130 T 110 T

Use T

130 T

110 T

Use T

Buss Tape Details:Conductive adhesiveHigh temperature rated adhesiveUL Listing for PV

Observations:Thermal fatigue ( T) is a significant accelerant for buss tape failureThe use of two or more stress conditions allow for extrapolation to use conditions and hence projections on ability to meet warranty for different climatic geographiesA third T condition will improve use condition prediction accuracy and narrow confidence bounds

Page 10: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 9

ReliaSoft Weibull++ 7 -­ www.ReliaSoft.com

Unreliability vs Time Plot

125%\Data 1: 100%\Data 1: 75%\Data 1:

Cycles

Unreliability, F(t)=1-­R(t)

0 20040 80 120 1600.0

1.0

0.2

0.4

0.6

0.8

Unreliability

75%\Data 1Lognormal-­2PRRX SRM MED FMF=3/S=2Data PointsUnreliability Line

100%\Data 1Lognormal-­2PRRX SRM MED FMF=10/S=0Data PointsUnreliability Line

125%\Data 1Lognormal-­2PMLE SRM MED FMF=5/S=0Data PointsUnreliability Line

Temperature Cycle with constant T, varied DC currentLooking at effects of three different current (irradiance) stress levels

Isc bias125% Iscbias

75% Iscbias

Buss Tape Details:Non-conductive adhesive

rating (i.e. not high temp rated)Former EMI tape with UL Listing for PV

Observations:Current (irradiance) is a significant accelerant for buss tape failure (ampacity)Tape UL Listing does not guarantee adequate PV reliability

ReliaSoft ALTA 7 -­ www.ReliaSoft.com

Acceleration Factor vs Stress

Beta=1.7932;; K=0.0008;; n=4.0975Current

Acceleration Factor

0 .0 2 .5 Isc0 .5 Isc Isc 1 .5 Isc 2 Isc0

100

20

40

60

80

Acceleration Factor

Data 1Inverse Power LawWeibull1.5F=28 | S=2AF Line

Page 11: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 10

Temperature Cycle with varied T, constant DC currentLooking at effects of two different manufacturing process parameters

ReliaSoft ALTA 7 -­ www.ReliaSoft.com

Use Level Probability Weibull

Experiment Split #2\Data 1: Beta=1.5954;; K=1.5744E-­10;; n=3.6665Experiment Split #1\Data 1: Beta=4.4504;; K=7.1642E-­10;; n=3.4347

Cycles

Unreliability

0 150003000 6000 9000 120000

1

0 .2

0 .4

0 .6

0 .8

Experiment Split #1\Data 1Inverse Power LawWeibull30F=10 | S=0Data PointsUnreliability Line

Experiment Split #2\Data 1Inverse Power LawWeibull50F=33 | S=1Data PointsUnreliability Line

Buss Tape Details:Conductive adhesiveHigh temperature rated adhesiveUL Listing for PV

ReliaSoft ALTA 7 -­ www.ReliaSoft.com

Use Level Probability Weibull

Experiment Split #2\Data 1: Beta=1.5954;; K=1.5744E-­10;; n=3.6665Experiment Split #1\Data 1: Beta=4.4504;; K=7.1642E-­10;; n=3.4347

Cycles

f(t)

0 200004000 8000 12000 160000

3 .E-­4

5 .E-­5

1 .E-­4

2 .E-­4

2 .E-­4

Experiment Split #1\Data 1Inverse Power LawWeibull30F=10 | S=0Pdf Line

Experiment Split #2\Data 1Inverse Power LawWeibull50F=33 | S=1Pdf Line

Split # 2

Split #1

Observations:Tape reliability can be significantly modulated with processing parameters / variability

Control your variability & optimize your process

Split #1

Split # 2

Page 12: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 11

Need to characterize and establish a Cell Temperature Model for your product based on readily available weather measurements such as ambient temperature, wind speed and irradiance 1, 2

Sampling rates of weather data can have a big influence on cycle counts, particularly on partly cloudy days. 3 This is often an issue with publically available weather data, which tends to average raw data or record measurements too infrequently (ex. hourly)

Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & Valley) and means to process weather data into temp cycle counts

5

Seasonality and geography are huge factors in the accumulation and magnitude of T cycles3

Quantifying T Cycle Counts from Weather Data

Page 13: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 12

Quantifying T Cycle Counts from Weather Data

Partly cloudy day

Sunny day

Page 14: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 13

Histograms of Cycle Count data1 minute data

Bin Frequency Cum %5 1627 91.71%10 65 95.38%20 50 98.20%30 22 99.44%40 3 99.61%50 3 99.77%60 2 99.89%70 2 100.00%

1 hour dataBin Frequency Cum %

5 9 45.00%10 2 55.00%20 0 55.00%30 1 60.00%40 1 65.00%50 6 95.00%60 1 100.00%70 0 100.00%

Hourly data grossly underestimates the amount of thermal fatigue during partly cloudy day

Page 15: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 14

Geography and measurement interval differences

Cycle count depends largely on location3

Readily available weather measurement data varies considerably1-hour interval weather data is very gross and inadequate to model predictions15-minute interval weather data is better, but not ideal1-minute interval weather data is best and recommended

Page 16: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 15

Tying lab data to weather for field projections

Multiple condition stress test data and actual field failure data can be enteredinto an accelerated life test analysis tool such as ALTA®

Data is used to find a best fit failure distribution curveData can include suspensions (i.e. modules that have survived someamount of time/stress majority of field samples)Temperature profiles can be fed into software as an input to account fordifferent geographies, times of year, etc.Monte Carlo analysis can be used to tighten confidence bounds whenanalysis sample sizes are limitedTime-to-failure, confidence intervals, failure mechanism activationenergies, acceleration factors, and warranty information can be calculatedat different geographies

Predictability

Page 17: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 16

FA techniques LBIC (Light Beam Induced Current)

LBIC used in conjunction with 2 cm lengths of perpendicular laser isolation

LBIC DescriptionScanning of a light beam over a cell while measuring the resulting short-circuit current for each position.The collected current variations are correlated to laser locations resulting in a current map.

Dark vertical line shows location where a 2 cm length of the metal buss tape is not making contact with the back metal

After additional stress testing, another 2 cm length of metal buss tape has failed

Page 18: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 17

FA Technique Acoustic Analysis

Page 19: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 18

FA Technique Acoustic Analysis (2)

Acoustic image of poor tape application that results in buss tape failure

Acoustic image of good tape application that results in reliable buss tape

Page 20: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 19

FA Technique - Thermography

Infrared (IR) imaging is a technique that has been in existence for a long time.Great at finding shunt related defects that have a high thermal emissionCannot easily detect series related resistances due to uniform thermal heatingTechnique is limited by spatial resolution and thermal diffusion due to integrating under full power over time

Lock-in Thermography (LIT) synchronizes the excitation source (light,

Allows detection of subtle thermal responses beyond the noise floor limitations of the IR camera. Mapping of the weaker shunting/series resistance defects are enabled because of the better detection limits.A much lower excitation is needed to acquire the thermal response on a module, this prevents over current/voltage stressing of the module which will result in damage.

Page 21: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 20

FA Technique - Infrared (IR) camera

IR image showing poor ohmic contact areas along metal buss tape prior to failure

IR spatial resolution and thermal diffusion usually limit its usefulness for buss tape analysis

Page 22: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 21

FA Technique Lock-in ThermographyInadequate buss tape

Post 24 CyclesTime Zero Post 74 CyclesOptical photo of film

surface

Page 23: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 22

FA Technique Lock-in Thermography (2)Inadequate buss tape

Optical image was overlaid onto the LIT image

High correlation of visible burned film and the lock-in thermal response.

Page 24: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 23

FA Technique Lock-in Thermography (3)Robust buss tape

Time zero Post 104 Cycles (2A)

Post 275 Cycles (2A)

Post 507 Cycles (2A)

Module shows no signs of film damage or degraded performance

Page 25: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 24

-Sven Goran Eriksson

-Walter Brunell

-Colin Powell

Dave Checkett

Benjamin Franklin

Page 26: Metal Buss Tape Reliability - Energy.gov · 2012. 3. 26. · Need to select a cycle counting algorithm3,4 (ex. Rainflow or Peak & ... 1-hour interval weather data is very gross and

Contains no confidential informationAbound Solar, Inc. 25

References

1. D.L. King, W.E. Boyson, and J.A. KrotochvilNational Laboratories SAND2004-3535, 2004.

2.vol.70, pp. 349-359, 2001

3.Reliability Workshop, 2011

4.1049-85, West Conshohacken, PA 2005.

5. D. Storera, StoFlo Rainflow Cycle Counting Excel Template with Macros, http://stotera.com/stoflo/