Menvier Fire Panels 70 Conventional Fire MF200 / MF400 Range This range of conventional fire panels offer a competitive solution for smaller installations. Both easy to install and operate. Supplied with battery & end of line devices Choice of 2 and 4 zone panels • 72 hour standby option (MF40072) • One man walk test facility • Auxiliary 24V dc output • Optional fire and fault relay PCB (MAR424) MF9300 Range The MF9300 range of conventional fire panels are designed for ease of installation and simple operation. All of the panels in this range can be either surface fixed or recessed mounted without the need of additional bezels or back boxes. Up to 32 detectors per zone Choice of 2, 4, 8 and 16 zone panels • 72 hour standby option (standard version) • One man walk test facility • Non-latching zone facility • Surface or recessed mounting

Menvier Fire Panels - Eworld Enterpriseeworldenterprise.weebly.com/uploads/7/8/7/5/7875975/cc... · 2018. 9. 6. · Menvier Fire Panels 70 Conventional Fire MF200 / MF400 Range This

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • Menvier Fire Panels

    70 Conventional Fire

    MF200 / MF400 Range

    This range of conventional fire panels offer a competitive

    solution for smaller installations. Both easy to install and

    operate.

    • Supplied with battery & end of line devices

    • Choice of 2 and 4 zone panels

    • 72 hour standby option (MF40072)

    • One man walk test facility

    • Auxiliary 24V dc output

    • Optional fire and fault relay PCB (MAR424)

    MF9300 Range

    The MF9300 range of conventional fire panels are

    designed for ease of installation and simple operation.

    All of the panels in this range can be either surface fixed

    or recessed mounted without the need of additional

    bezels or back boxes.

    • Up to 32 detectors per zone

    • Choice of 2, 4, 8 and 16 zone panels

    • 72 hour standby option (standard version)

    • One man walk test facility

    • Non-latching zone facility

    • Surface or recessed mounting

  • Conventional Fire

    Fire Systems

    71

    Catalogue Numbers

    Product Code Zones Standby (hrs) Weight (kg)

    MF200 / MF400 Range

    MF200 2 24 4.8

    MF400 4 24 4.8

    MF40072 4 72 6.0

    MF9300 Range

    MF9302 2 72 10.6

    MF9304 4 72 10.6

    MF9308 8 72 16.8

    MF9316 16 72 16.9

    MF9308L 8 24 16.0

    MF9316L 16 24 16.0

    MF9300 Repeater Panels

    MFR9308 8 72 16.8

    MFR9316 16 72 17.2

    Optional Accessories Description

    MAR424 Fire and Fault Relay Unit (for MF200 and MF400)

    Dimensions

    Options H W D/D1 D2 Cut out

    (mm) (mm) (mm) (mm) (mm)

    MF200 / MF4002 / 4 Zone 300 300 74 - -

    MF9300 Recessed2 / 4 Zone 344 395 25 70 324 x 3858 / 16 Zone 386 395 25 119 376 x 385

    Note: If surface mounting, add D1 & D2 to obtain depth dimension.

    Product Code MF200 MF400 MF9302 MF9304 MF9308 MF9316

    Number of Zones 2 4 2 4 8 16

    Detectors Per Zone 20 32

    Number of Alarm Circuits 2 2 4

    Alarm Circuit Load 375mA per circuit. 750mA total 500mA per circuit. 1A total 500mA per circuit. 2A total

    End of Line Devices Detection circuits: 22kΩ resistor Detection circuits: 12kΩ resistor

    Alarm lines: 22kΩ resistor Alarm lines: 12kΩ resistor

    Auxiliary Fire Signal Output 24V dc pull to 0V. Max 10mA 1A 24V dc (resistive) single pole change over contacts

    Auxiliary Fault Output 24V dc pull to 0V. Max 10mA 1A 24V dc (resistive) single pole changeover contacts

    Auxiliary Common Output 24V dc pull to 0V. Max 10mA - - - -

    Auxiliary dc Output 24V dc fused. 32mA 24V dc fused. 100mA 24V dc fused. 350mA

    (up to 100mA at the expense of alarm load)

    Repeater Output - -

    2 wire serial link

    (Repeater also requires separate 230V AC supply)

    Mains Input Voltage 240V ac +10%-15% 230V ac ±10%. 50/60 Hz 240V ac +10%-15% 230V ac ±10%. 50/60 Hz

    Standby Duration 24 hours (72 hours on MF40072) 72 hours (24 hours option on 8 & 16 zone)

    System Operating Voltage 24V dc 24V dc

    Battery 1 x 4Ah sealed lead acid battery 2 x 7Ah sealed lead acid battery 2 x 12Ah sealed lead acid battery

    (1 x 7Ah on MF40072) (2 x 7Ah for 24 hour version)

    Recharge Period 48 hours (80% in 24 hours) 24 hours

    Panel Construction ABS/Polycarbonate housing ABS/Polycarbonate housing ABS/Polycarbonate housing

    Steel back box Steel back box Steel back box

    Cable Entries Top: 10 x 20mm knockout Top: 13 x 20mm knockouts Top: 27 x 20mm knockouts

    Bottom: 1 x 20mm knockout back: 1 x 20 mm knockouts back: 1 x 20 mm knockouts

    Back: 1 x mains cable entry slot

    Environmental Rating IP30. -5°C to +40°C. IP20. -5°C to +40°C

    Humidity 75% max (non-condensing) Humidity 75% max (non-condensing)

    Technical Specification

    D W

    H

    W

    H

    D2

    D1

    MF200 / MF400 MF9300

  • JSB Fire Panels

    72 Conventional Fire

    FX2200 Range

    The FX2200 range of panels provide a solution to

    any conventional system requirement. Features include

    a simple “one-shot” user test facility, class change

    contacts, battery voltage alarms and charger

    temperature compensation. For larger installations,

    custom configuration of the panels offers even greater

    flexibility, allowing project specific requirements to be

    easily met, in a competitive and cost effective package.

    • Supplied with battery & end of line devices

    • Choice of 1, 2, 4 or 8 zones

    • Maintenance free polyswitch circuit protection

    • Custom configured versions available

    FX4200 Range

    Easy to install and use, the FX4200 range of

    conventional fire panels delivers fire detection and alarm

    facilities at exceptional value for money. Designed with

    smaller installations in mind, a choice of 2, 4 and 8 zone

    compact panels are available. The FX4200 range’s

    standard features, such as class change, zone or

    sounder circuit disabling and programmable relay output

    facilities complete a highly competitive solution.

    • Supplied with battery & end of line devices

    • Choice of 2, 4 or 8 zones

    • Simple ‘one shot’ auto reset user test facility

    • Programmable fire / fault output relay

  • Conventional Fire 73

    Catalogue Numbers

    Product Code Zones Standby (hrs) Weight (kg)

    FX4200 Range

    FX4202 2 24 4.8

    FX4204 4 24 4.8

    FX4208 8 24 6.2

    FX2200 Range

    FX2201 1 24 5.2

    FX2202 2 24 5.2

    FX2204 4 24 5.8

    FX2208 8 24 6.0

    FX2200 Range (Configured for use with a repeater)

    FX2202CR 2 24 5.8

    FX2204CR 4 24 5.8

    FX2200 Repeater Panel

    FXRP2200 8 24 6.0

    Optional Accessories Description

    FX22003300 MB Semi Recessing box for the FX2200 ( 2, 4, 8 zone)

    Dimensions

    Options H W D/D1 D2 Cut out

    (mm) (mm) (mm) (mm) (mm)

    FX42002 / 4 Zone 300 300 74 - -8 Zone 265 391 105 - -

    FX22001 Zone 212 260 72 - -2 / 4 / 8 Zone 270 332 45 47 265 x 327

    Note: If surface mounting, add D1 & D2 to obtain depth dimension.

    Product Code FX4202 FX4204 FX4208 FX2201 / FX2202 FX2204 FX2208

    Number of Zones 2 4 8 1 / 2 4 8

    Detectors Per Zone 20 20

    Number of Alarm Circuits 2 2 4

    Alarm Circuit Load 150mA per circuit 400mA per circuit 150mA per circuit 400mA per circuit 500mA per circuit

    0.3A total 0.8A total 0.3A total 0.8A total 2.0A total

    End of Line Devices Detection circuits: EOLM-1 monitoring unit Detection circuits: EOLM-1 monitoring unit

    Alarm lines: 6.8kΩ resistor Alarm lines: 6.8kΩ resistor

    Auxiliary Relay(S) Single relay selectable fire or fault Single relay selectable fire or fault fire and fault

    5A 24V dc single pole CO contacts 5A 24V dc single pole CO contacts

    Auxiliary dc Output 24V dc. 30mA - - 24V dc. 30mA

    Mains Input Voltage 240V ac +10%-15% 240V ac +10%-15%

    Standby Duration 24 hours 24 hours

    System Operating Voltage 24V dc 24V dc

    Battery 1 x 3.2Ah 1 x 3.2Ah 2 x 3.2Ah

    Recharge Period 24 hours 24 hours

    Panel Construction Polycarbonate housing & back box Polycarbonate housing & back box

    Cable Entries Top: 10 x 20mm Top: 17 x 20mm Top: 10 x 20mm Top: 10 x 20mm

    Bottom: 1 x 20mm Rear cable entry conduct entries conduct entries

    Rear cable entry Rear cable entry Rear cable entry

    Environmental Rating IP30. -5°C to +40°C. IP30. -5°C to +40°C.

    Humidity 75% max (non-condensing) Humidity 75% max (non-condensing)

    Technical Specification

    D W

    H

    W

    H

    D2

    D1

    1 2 3 4 5

    SCROLLMUTE

    BUZZER

    FX4200 FX2200

    Fire Systems

  • Detectors and Detector Bases

    74 Conventional Fire

    Menvier and JSB Detector Bases

    Two conventional detector mounting base types are

    available which have been specifically designed to be

    compatible with respective Menvier or JSB detectors

    and their associated control panels. The bases have

    been designed for flexibility, simplicity and speed of

    installation.

    • Selectable detector locking feature

    • Separate zone in and out connections

    • Base incorporates features to support surface wiring

    Menvier and JSB Detectors

    The Menvier and JSB ranges of conventional detectors

    have been specifically designed to operate with their

    respective control panels. The Menvier 800/900 range

    and JSB FXN500/600 range of conventional detectors

    are third party approved to the relevant section of EN54.

    • LPCB approved

    • Drift compensation

    • Ultra low profile, 360° viewing angle LED

    • Photo/Thermal alternative to old ionisation types

  • Conventional Fire 75

    Catalogue Numbers

    Product Code Description

    Menvier Detectors

    MPD821 Optical Detector

    MPT951 Photo/Thermal Detector

    MMT860 Fixed Heat Detector (77ºC)

    MHT890 Fixed Heat Detector (92ºC)

    MFR830 Rate of Rise Detector

    Menvier Detector Base

    MDB800 Common Mounting Base

    JSB Detectors

    FXN533 Optical Detector

    FXN632 Photo/Thermal Detector

    FXN524 Fixed Heat Detector (77ºC)

    FXN526 Fixed Heat Detector (92ºC)

    FXN525 Rate of Rise Detector

    JSB Detector Base

    FXN520 Common Mounting Base

    Dimensions

    Options Dia D (excluding base) D (including base)

    (mm) (mm) (mm)

    Menvier and JSB DetectorsOptical Detector 101 33 45Photo/Thermal Detector 101 43 55Heat Detectors (77 / 92 / RoR) 101 43 55

    Menvier and JSB Detector BasesDetector Base 104 22 -

    D

    Dia

    Dia

    D

    Detector BaseDetector

    Optical Detector

    Photo/Thermal Detector

    Heat Detector

    Fire Systems

  • Sounders

    76 Conventional Fire

    Speech Sounders

    • 100dB(A) output

    • Clear intelligible human speech

    Flush Sounders

    • Low profile design

    • Volume control

    Ceiling Mounted Sounder

    • Reduced install time

    • Optional blanking (for use without a detector)

    Discreet Sounder

    • Audible and visual alarm

    • LED indication

    Surface Sounders - Low Profile

    • Choice of colour

    • 32 selectable tones

    Surface Sounders - Weatherproof

    • Weatherproof design

    • Choice of cable entry

    Sounders - High Output

    • Choice of tones

    • Ideal for areas with high ambient noise

    Sounders - Low Current

    • Simple to install

    • High efficiency design

    Speech Sounders Flush Sounders Ceiling Mounted Sounder

    Discreet Sounder Low Profile / Weatherproof Sounders High Output / Low Current Sounders

  • Conventional Fire 77

    Catalogue Numbers

    Product Code Description

    Menvier Speech Sounders

    MSS7MR 24V Speech Sounder (red) Message A

    MSS20MR 24V Speech Sounder (red) Message B

    MSS28MR 24V Speech Sounder (red) Message C

    MSS7MW 24V Speech Sounder (white) Message A

    MSS20MW 24V Speech Sounder (white) Message B

    MSS28MW 24V Speech Sounder (white) Message C

    Menvier Flush Sounders

    MFS324 Flush Sounder (red)

    MFS324W Flush Sounder (white)

    Menvier Ceiling Mounted Sounder

    MDS824 Ceiling Mounted Sounder

    MDS824COV Cover Plate - pack of 5

    Menvier Discreet Sounder

    600112FUL-0000 Discreet Sounder

    Menvier Surface Sounders

    MWS424SB Surface Sounder - Low Profile (red)

    MWS424DB Surface Sounder - Weatherproof (red)

    Menvier Sounder - Low Current

    MLC624 Sounder - Low Current (red)

    JSB Flush Electronic Sounder

    FX003 Flush Sounder (red)

    JSB Surface Sounders

    FX002 Surface Sounder - Low Profile (red)

    FX002W Surface Sounder - Low Profile (white)

    FX000WP Back box - Weatherproof (red)

    JSB Sounder - High Output

    FX007 Sounder - High Output (red)

    Dimensions

    Options H W D Dia

    (mm) (mm) (mm) (mm)

    Speech Sounder - - 105 95

    Flush Sounder 86 86 36 -

    Ceiling Mounted Sounder - - 26 111

    Discreet Sounder 87 87 30 -

    Sounder - Low Profile - - 63 93Sounder - Weatherproof - - 93 93

    Sounder - High Output 105 105 95 -Sounder - Low Current 105 105 95 -

    Dia

    D

    D

    W

    H

    D

    Dia

    D

    Dia

    D

    H

    W

    Dia

    D

    D

    H

    W

    D

    H

    W

    Speech Sounder Flush Sounder

    Ceiling Mounted Sounder Discreet Sounder

    Sounder - Weatherproof

    Sounder - Low Current

    Sounder - Low Profile

    Sounder - High Output

    Fire Systems

  • Beacons and Sounder Beacons

    78 Conventional Fire

    Xenon Beacons / Weatherproof Xenon Sounder Beacons / Weatherproof LED Beacons / Weatherproof

    LED Sounder Beacons / Weatherproof

    Xenon Beacons

    • High light output

    • Weatherproof version supports side entry surface cables

    • Unobtrusive low profile design

    Xenon Sounder Beacons

    • Sounder & beacon with a single installation point

    • Weatherproof version

    LED Beacons

    • Low profile consumption

    • Discreet low profile design

    • Choice of flashing frequency

    LED Sounder Beacons

    • Sounder & beacon with a single installation point

    • Choice of cable entries

    • Weatherproof version

    LED Ceiling Mounted Sounder Beacon

    • Reduced install time

    • Optional blanking (for use without a detector)

    LED Ceiling Mounted Sounder Beacon

  • Conventional Fire 79

    Catalogue Numbers

    Product Code Description

    Menvier Xenon Beacons

    MXB124SB Xenon Beacon - Low Profile (red)

    MXB124DB Xenon Beacon - Weatherproof (red)

    Menvier Xenon Sounder Beacon

    MCD524SB Xenon Sounder Beacon - Low Profile (red)

    MCD524DB Xenon Sounder Beacon - Weatherproof (red)

    Menvier LED Beacon

    MLB124SB LED Beacon

    MLB124DB LED Beacon - Weatherproof

    Menvier LED Sounder Beacon

    MSB124SB LED Sounder Beacon

    MSB124DB LED Sounder Beacon - Weatherproof

    Menvier LED Ceiling Mounted Sounder Beacon

    MDS824B LED Ceiling Mounted Sounder Beacon

    MDS824COV Cover Plate - pack of 5

    JSB Xenon Beacons

    FX004R Xenon Beacon - Low Profile (red)

    FX004A Xenon Beacon - Low Profile (amber)

    FX004B Xenon Beacon - Low Profile (blue)

    JSB Xenon Sounder Beacon

    FX002CR Xenon Sounder Beacon (red)

    FX002CA Xenon Sounder Beacon (amber)

    FX002CB Xenon Sounder Beacon (blue)

    Dimensions

    Options D Dia

    (mm) (mm)

    Xenon Beacon - Low Profile 72 93Xenon Beacon - Weatherproof 101 93

    Xenon Sounder Beacon - Low Profile 92 93Xenon Sounder Beacon - Weatherproof 121 93

    LED Beacon 53 95LED Beacon - Weatherproof 80 95

    LED Sounder Beacon 80 93LED Sounder Beacon - Weatherproof 109 95

    LED Ceiling Mounted Sounder Beacon 26 111

    D

    Dia

    D

    Dia

    D

    Dia

    D

    Dia

    D

    Dia

    Xenon Beacon - Low Profile Xenon Beacon - Weatherproof

    Xenon Sounder Beacon - Low Profile

    Xenon Sounder Beacon -Weatherproof

    LED Beacon - Weatherproof

    LED Sounder Beacon - Weatherproof

    LED Beacon

    LED Sounder Beacon

    Dia

    D

    LED Ceiling Mounted Sounder Beacon

    Fire Systems

  • Ancillaries

    80 Conventional Fire

    Bells / Weatherproof Callpoints / Weatherproof

    Door Retainers - Heavy Duty

    Remote Indicator

    Relay Unit - Heavy Duty

    Bells

    • High sound output

    • Low current consumption

    • Weatherproof version

    Callpoints

    • Fast fit clip on front cover

    • Heavy duty terminals

    • Weatherproof version

    Remote Indicator

    • Simple to Install

    • Fits onto standard single gang back box

    • High brightness LED

    Door Retainers - Heavy Duty

    • Heavy duty construction

    • Manual release facility

    • Mains and 24V versions

    Door Retainers - Compact

    • Compact dimensions

    • Manual release facility

    • Mains and 24V versions

    Relay Unit - Heavy Duty

    • Simple to Install

    • Visible status LED

    • 2 sets of contacts

    Door Retainers - Compact

  • Conventional Fire 81

    Catalogue Numbers

    Product Code Description

    Menvier Bells

    MBM246 150mm Bell - Internal

    MWB824 200mm Bell - Weatherproof

    Menvier Callpoints

    MBG914 Callpoint - Surface / Flush

    MBG917 Callpoint - Weatherproof

    Menvier Heavy Duty Door Retainers

    MDR240 Heavy Duty Door Retainer (mains powered)

    MDR24L Heavy Duty Door Retainer (24V dc powered)

    ZMDRFBB Floor Mounting Bracket

    Menvier Relay Unit - Heavy Duty

    MAR724 Relay Unit - Heavy Duty

    JSB Bells

    FX006 150mm Bell

    JSB Callpoints

    FX201 Callpoint - Surface / Flush

    FX203 Callpoint - Weatherproof

    Remote Indicator

    FXD251D Remote Indicator

    JSB Compact Door Retainers

    FX021240LC Compact Door Retainer (mains powered)

    FX02124VLC Compact Door Retainer (24V dc powered)

    FX021LCFB Floor Mounting Bracket

    Dimensions

    Options H W D Dia

    (mm) (mm) (mm) (mm)

    150mm Bell - Internal - - 63 152200mm Bell - Weatherproof - - 104 200

    Callpoint - Surface / Flush 87 87 57 / 36 -Callpoint - Weatherproof 108 108 70 -

    Remote Indicator 87 87 30 -

    Door Retainer - Heavy DutyMagnet 95 95 40 -Sticker Plate 65 65 48 -

    Door Retainer - CompactMagnet 71 108 41 -Sticker Plate 65 65 48 -

    Relay Units - Heavy Duty 87 87 30 -

    D

    Dia

    Dia

    D

    W

    W

    D

    D

    H

    H

    W

    WD

    D

    H

    H

    D

    H

    W

    W

    H

    D

    Bell - Internal Bell - Weatherproof

    Callpoint Remote Indicator

    Door Retainer - Compact

    Relay Unit - Heavy Duty

    Door Retainer - Heavy Duty

    Fire Systems