Page 1: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Menvier Fire Systems

Page 2: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

2

ONE COOPEREvery day, thousands of people all over the world use products made by Cooper

Industries. As a premier global manufacturing company, we believe that great brands are

built on high quality and excellent service. Which is why our brands have earned leading

positions in the markets we serve. Cooper Safety specialises in products designed to save

lives and protect property in commercial, industrial and residential buildings. It’s just one

of the seven divisions that continue to uphold our reputation through unparalleled sales

support and customer service.

Page 3: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

3

Conventional

5 Conventional Contents 7 Fire Panels15 Detectors17 Standard Base19 Relay Base21 Remote Indicator23 Reflective Beam Detectors25 Callpoints27 Bells29 Flush Sounders31 Sounder and Sounder Beacon33 Surface Sounders37 Xenon Beacons41 LED Beacons45 Door Retainers

Intelligent Addressable

47 Intelligent Addressable Contents49 Fire Panels61 Repeater Panels65 Sensors67 Standard Base69 Sounder Base71 Sounder Beacon Base73 Loop Connected Remote Indicator75 Reflective Beam Detectors77 Callpoints79 Wall Sounders81 Wall Sounder Beacons83 LED Beacons85 Interfaces97 Micro Interfaces

Ancillaries and Test Equipment

103 Heavy Duty Relay Unit105 Power Supply Unit107 Loop Tester Kit108 Addressable Device Programmer

Page 4: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

4

About us

Cooper Safety Fire Systems

Cooper Fire offers a comprehensive rangeof Menvier fire detection products suitablefor a wide range of projects, from a smallsimple installation to a large complex multibuilding site.

Cooper Fire manufacture a wide range ofproducts and offers complete firesolutions, not just individual components.A complete system can be specified froma single source, confident in theknowledge that all the components havebeen specifically designed and tested to

ensure they are all fully compatible witheach other and will function as a trulyintegrated fire detection and alarm system.

It is absolutely vital that all the elements ofa fire detection system are fully compatiblewith each other. To support thisphilosophy, a large multi-disciplinedresearch and development team is basedin the UK at the Cooper Doncaster facility,responsible for the integration of the verylatest technology into the design of ourcomprehensive range of fire products.

LO

SS

PR

EV

EN

T

ION C E R T I F I C

AT

I ON

BO

A

RD

LPCBLPCB

Page 5: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

5

Conventional Contents

Page 7Control PanelsMF9300

Page 11Control PanelsMF200 and MF400

Page 15DetectorsMPD821, MPT951, MFR830MMT860 and MHT890

Page 17Standard BaseMDB800

Page 19Relay BaseMDB800R

Page 23Reflective Beam DetectorsMBD50R and MBD100R

Page 25Callpoints MBG914 and MBG917

Page 27Bells MBM246. MBM248 andMWB824

Page 29Flush Sounders MFS324 and MFS324W

Page 31Sounder and Sounder Beacon MDS824 and MDS824B

Page 33Surface SoundersMWS424SB and MWS424DB

Page 35Low Current SounderMLC624

Page 37Xenon Beacons MXB124SB and MXB124DB

Page 39Xenon Sounder BeaconsMCD524SB and MCD524DB

Page 41LED Beacons MLB124SB and MLB124DB

Page 43LED Sounder BeaconMSB124SB and MSB124DB

Page 45Heavy Duty Door RetainersMDR240 and MDR25L

Page 21Remote Indicator CIR301

Page 6: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

6

Conventional System Architecture

The philosophy of a conventional system revolvesaround dividing the building into a number of areascalled zones. The detectors and callpoints withineach zone are then wired on dedicated circuits. In theevent of a detector or callpoint being triggered,the panel is able to identify which circuit contains thetriggered device and thereby indicate which zone thefire alarm has come from.

It is then necessary to manually search the indicatedzone to pinpoint the exact cause of the fire alarm.

Unwanted AlarmsBecause most conventional detectors are simple twostate devices they can only be in either a normal orfire condition. Although modern components andgood system design can go some way to reducingpotential problems, it is not uncommon forconventional systems to generate unwanted alarmsdue to certain operating conditions or transientenvironmental conditions such as the presence ofsteam near to a smoke detector.

A key development aimed at reducing such unwantedalarms has been the multi-criteria detector.Traditionally, detectors were designed to respond toparticular fire phenomena such as heat or thepresence of smoke. However, Cooper now offermulti-criteria devices, which contain both a smokesensing element and a thermal sensing element.

The fire alarm decision is taken by analysis of theresponses from both elements, resulting in improveddetection performance as well as greatly enhancedfalse alarm suppression.

Sounder CircuitsIn addition to the detection circuits, there is also aneed for separate circuits of alarm annunciationdevices such as sounders and beacons to signal theexistence of a fire alarm condition to the buildingusers. For sounder circuit continuity monitoring tofunction effectively, sounder circuits have to be wiredin a single radial circuit, spurs and tees are notpermitted.

Almost every conventional fire panel will havefacilities for more than one sounder circuit andgenerally the higher the specification of the panel orthe higher the number of detection zones provided,the more sounder circuits will be provided.

Normally however there will be less sounder circuitsthan detection zone circuits so it will be necessary fora sounder circuit to provide cover for more than onezone.

This increases installation complexity by forcing thesounder wiring to follow different routes to that of thedetector wiring.

When designing a conventional system it is importantto ensure that the panel has adequate zone capacityfor the size and complexity of the building and thatthe panel can support the intended sounder circuitwiring and loading.

Zone 2

Zone 4

Zone 1

Zone 3

Page 7: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

7

MF9300 Range Control Panel

Overview

The Menvier MF9300 is a range of high specificationconventional control panels designed for a widerange of building types and sizes at a competitiveprice.

Available in a choice of 2, 4, 8 or 16 zone versions, theMF9300 range is designed for ease of installation andsimple operation.

All panels can be either surface or flush mounted,without the need of additional bezels or back boxes.

System flexibility is emphasised by the availability ofmatching repeater panels for the 4, 8 and 16 zonepanels.

MFR9300 repeater panel

Features• 2, 4, 8 or 16 zone panels• Matching repeaters available

for 4, 8 and 16 zone panels • Coincidence detection and

non-latching zone features on 4, 8 and 16 zone panels

• Surface or flush mounting option as standard

• Up to 32 detectors per zone• 72 hour standby as standard• 24 hour standby available

Benefits• Designed for ease of installation• One man walk test facility• Fully compatible with Menvier

range of ancillaries

simple access to connection terminals and batteries

MF9304 control panel

Page 8: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

8

Conventional Control Panel - MF9300 Range

Code MF9302 MF9304 MF9308 MF9316

Description 2 zone control panel 4 zone control panel 8 zone control panel 16 zone control panel

Standards EN54 Pt2 & Pt4 1998 EN54 Pt2 & Pt4 1998 EN54 Pt2 & Pt4 1998 EN54 Pt2 & Pt4 1998

EN50130-4:1996 EN50130-4:1996 EN50130-4:1996 EN50130-4:1996

EN500081-1:1992 & EN61000-2-2:1994 EN500081-1:1992 & EN61000-2-2:1994 EN500081-1:1992 & EN61000-2-2:1994 EN500081-1:1992 & EN61000-2-2:1994

Specification

Number of Zones 2 4 8 16

Detectors per Zone 32 32 32 32

Number of Alarm Circuits 2 2 4 4

Alarm Circuit Load 500mA per circuit. 1A total 500mA per circuit. 1A total 500mA per circuit. 2A total 500mA per circuit. 2A total

End of Line Devices Detection circuits: 12KΩ resistor Detection circuits: 12KΩ resistor Detection circuits: 12KΩ resistor Detection circuits: 12KΩ resistor

Alarm lines: 12KΩ resistor Alarm lines: 12KΩ resistor Alarm lines: 12KΩ resistor Alarm lines: 12KΩ resistor

Auxiliary Fire Signal Output 1A 24V dc (resistive) single pole 1A 2 4V dc (resistive) single pole 1A 24V dc (resistive) single pole 1A 24V dc (resistive) single pole

changeover contacts. Isolate facility available changeover contacts. Isolate facility available changeover contacts. Isolate facility available changeover contacts. Isolate facility available

Auxiliary Fault Output N/A 1A 2 4V dc (resistive) single pole 1A 24V dc (resistive) single pole 1A 24V dc (resistive) single pole

changeover contacts changeover contacts changeover contacts

Auxiliary Common Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA

Auxiliary dc Output 24V dc fused. 100mA 24V dc fused. 100mA 24V dc fused. 350mA 24V dc fused. 350mA

Repeater output N/A 2 wire serial link 2 wire serial link 2 wire serial link

(repeater also requires separate 230V ac supply) (repeater also requires separate 230V ac supply) (repeater also requires separate 230V ac supply)

Mains Input Voltage 230V ac ±10%. 50/60Hz 230V ac ±10%. 50/60Hz 230V ac ±10%. 50/60Hz 230V ac ±10%. 50/60Hz

System Operating Voltage 24V dc 24V dc 24V dc 24V dc

Standby Duration 72 hours 72 hours 72 hours (24 hours option) 72 hours (24 hours option)

Battery 2 x 7Ah sealed lead acid battery 2 x 7Ah sealed lead acid battery 2 x 12Ah sealed lead acid battery 2 x 12Ah sealed lead acid battery

Recharge Period 24 hours 24 hours 24 hours 24 hours

Environmental

Operating Temperature -5°C to +40°C -5°C to +40°C -5°C to +40°C -5°C to +40°C

Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH 0 to 75% RH

Physical

Construction ABS/Polycarbonate housing & back box ABS/Polycarbonate housing & back box ABS/Polycarbonate housing & steel back box ABS/Polycarbonate housing & steel back box

Dimensions (H x W x D) 344mm x 395mm x 95mm 344mm x 395mm x 114mm 386mm x 395mm x 114mm 386mm x 395mm x 114mm

Weight 10.6kg 10.6kg 16.8kg (24 hours option 16.0kg) 16.9kg (24 hours option 16.0kg)

Ingress Protection IP20 IP20 IP20 IP20

Cable entries Top: 13 x 20mm knockouts Top: 13 x 20mm knockouts Top: 27 x 20mm knockouts Top: 27 x 20mm knockouts

Back: 1 x 20mm knockout Back: 1 x 20mm knockout Back: 1 x 20mm knockout Back: 1 x 20mm knockout

Technical Specification

Code DescriptionMF9302 Conventional 2 zone control panelMF9304 Conventional 4 zone control panelMF9308 Conventional 8 zone control panelMF9316 Conventional 16 zone control panelMF9308L Conventional 8 zone control panel (24 hour standby)MF9316L Conventional 16 zone control panel (24 hour standby)MFR9308 Conventional 8 zone repeater panelMFR9316 Conventional 16 zone repeater panelMFALOG Fire alarm system log book

Product Codes

Dimensions

W

H

D2

D1

Description H (mm) W (mm) D1 (mm) D2 (mm)MF9302 344 395 25 70MF9304 344 395 25 70MF9308 386 395 25 119MF9316 386 395 25 119MFR9308 386 395 25 119MFR9316 386 395 25 119

Description Cut-out (mm)MF9302 324 x 385MF9304 324 x 385MF9308 376 x 385MF9316 376 x 385

Note: If surface mounting add D1 and D2 to obtain depth dimension.

Note: If a repeater panel is required to operate with the MF9304, use the MFR9308, 8 zone repeater.

Page 9: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Control Panel - MF9300 Range

9

Installation1. A full set of installation and user instructions is

supplied with each panel to assist the installer to carry out the work efficiently and safely, and the end user to perform routine tests.

2. Panels are designed to be wall mounted. When surface fixed use keyhole slot mounting holes found on back of housing, if recessed mounted use an appropriate cut-out for panel and fixed via 6 x screw fixing holes around the housing flange.

3. Mains power supply cable must be routed via the designated 20mm conduit entry knockouts on the top or rear of the housing. The mains terminal block is provided with fuse protection.

4. Conduit entry knockouts are provided on the top ofthe housing for zone, alarm and output cables. A total of 13 (2/4 zone) or 27 (8/16 zone) knockouts are provided.

5. Standby batteries are connected via push-on terminal connectors.

6. End of line (EOL) devices are supplied with the panel and must be fitted at the end of each detector and alarm circuit wiring.

7. Front cover is screw fixed with hinged battery compartment door and hinged upper door for access to zone/alarm connections and configuration settings, which requires use of a special tool for access.

System Functionality1. Normal and supervisor mode facility. Supervisor

mode protected by 4 digit security code to prevent unauthorised use. Service engineer and configuration modes accessed by further security codes.

2. Supervisor mode provides access to test mode, where zones can be tested individually or in any combination.

3. One man walk test feature permits each manual callpoint and detector on the zone(s) in test mode to be put into fire condition and activates the alarms for 2 seconds. Panel automatically resets the zone(s) 10 seconds after each device has beentested. A fire condition received from a zone not in test mode results in an immediate alarm, overridingthe test mode.

4. Supervisor mode also provides facility to disable/isolate the following for maintenance or other purposes• each detection zone independently• the alarm circuits• the remote signal output (except 2 zone panel)

5. Non-latching zone facility can be selected on one zone, enabling the direct interconnection of panels in a simple network.

6. Coincidence detection facility can be selected on

one zone (except 2 zone panel). An alarm conditionis dependant upon a fire signal from 2 detectors within a defined period, when facility is selected. A single detector fire signal is indicated by sounding the integral buzzer and flashing LED on the panel. Any fire signal from a manual callpoint on the zone immediately operates the alarm.

7. An alarm line delay feature can be selected (except2 zone panel). Preset delays of 1 to 7 minutes can be programmed during commissioning, permanently illuminating a panel indicator when set. Indicator and zone LED flash when fire signal is received and delay is in operation. Any fire signalfrom a manual callpoint immediately operates the alarm.

User Interface1. Stylish and attractive panel with easy to use 8

button keypad to control all functions.2. Comprehensive power, fire and fault LED

indicators and integral piezo buzzer for on-board fire or fault indication.

3. Panel can be surface mounted or recessed, without the need of an additional fixing bezel or back box.

4. Special tool used to release hinged upper door to access connections and configuration settings or bottom door to access battery.

Interface Options1. Class change input facility. Terminals provided for

switching of alarm circuits to indicateschool/college class change.

2. Auxiliary 1A 24V dc fault relay (except 2 zone panel).

3. Remote signal 1A 24V dc relay for remote location signalling, or operation of a remote dialler (can be isolated during tests/servicing).

4. 24V dc common output provided (does not operate with non-latching zone).

5. Auxiliary 24V dc output power supply provided as standard.

Detection Capacity1. Up to 32 detectors per zone. End of line

monitoring devices must be fitted and are suppliedas standard.

2. Detector circuits are monitored for open circuit, short circuit and detector removal.

Alarm Capacity1. 2 separate alarm lines on 2 and 4 zone panels.

500 mA maximum load per line.2. 4 separate alarm lines on 8 and 16 zone panels.

500mA maximum load per line.3. Alarm lines are monitored for open circuit and

short circuit faults.

Repeater Panels1. Repeaters match the style and

appearance of main controlpanels.

2. Facility for signalling to repeater panels provided on allmain panels (except 2 zone).

3. Displays essential information at other key locations in a largebuilding/site.• Zone fire or fault conditions• Zones or alarm lines in test

mode• Zones or alarm lines in

disabled mode• Alarm delays• Faults, isolations and test

mode for control outputs4. Repeater panel requires only a

single pair of wires to receivesignals from main control panel, plus local mains power supply, reducing cost of installation.

Page 10: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

10

Conventional Control Panel - MF9300 Range

NOTES:1. All sounders must be polarised and suppressed.2. Connection details for door release units when required.3. Connection details for repeater panels when required.

ZONE1

ZONE15

ZONE14

ZONE13

ZONE12

ZONE10

ZONE8

ZONE11

ZONE9

ZONE7

ZONE6

ZONE5

ZONE4

ZONE16

ZONE3

ZONE2

ALARM

1

ALARM

2

ALARM

4

ALARM

3

EA

RT

H

FAULT

RELAY

REMOTE

SIGNAL

RELAY

AU

XIL

IAR

Y 2

4V

DC

OU

TP

UT

AU

XIL

IAR

Y C

OM

MO

N O

UT

PU

T (

NO

TE

2)

CLA

SS

CH

AN

GE

RE

PE

AT

ER

GR

OU

ND

RE

PE

AT

ER

TR

AN

SM

IT

- + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + NC NOC NC NOC - + - +

MDB800DETECTOR

BASE

MBG914/917CALLPOINT

connect as per instructions

- VE IN & OUT

ON 2

+ VE IN & OUT

ON 1

END OF LINE12K RESISTOR

subsequent zones

END OF LINE12K RESISTOR

subsequent alarm lines

(NOTE 1)

+

+

+

FAU

LT

TO A

PP

LIC

ATIO

NS

R

EQ

UIR

ING

RE

LAY

W

ITH

ISO

LATI

NG

FA

CIL

ITY

TO V

OLT

FR

EE

CO

NTA

CTS

TO R

EP

EAT

ER

PA

NE

L(N

OTE

3)

+

-MAR724HEAVYDUTYRELAY

NC NC

C C

TO DOOR RELEASE UNITS

230V ac +/- 10% 50/60Hz

24V dc 10mA COIL

Standard Panel Connections

Page 11: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

11

MF200 and MF400 Range Control Panels

Overview

The Menvier MF200 and MF400 range ofconventional control panels offer a competitivesolution for smaller installations.

Easy to install and operate, the panels are designedto provide fire detection and alarm facilities inbuildings where the basic elements of protection tomeet BS5839 are required.

Available as either a 2 zone or 4 zone panel with upto 20 detectors per zone can be connected.

This range of Menvier control panels are convenientlysupplied complete with end of line devices andbatteries offering 24 hours standby as standard, withthe option of 72 hours on the 4 zone version.

One man walk test and class change facilities,along with 24V dc remote signalling fire and faultoutputs augment a value for money range.

MAR424 fits inside MF200 and MF400 panels

Features• 2 or 4 zone panels• Competitively priced• Supplied complete with battery

and end of line devices

Benefits• Simple end user operation• One man walk test facility• Fully compatible with Menvier

range of ancillaries

MAR424 remote fire and fault relay PCB

MF200 control panel

Page 12: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

12

Conventional Control Panels - MF200 and MF400

DimensionsD W

H

H (mm) W (mm) D (mm)300 300 74

Code DescriptionMF200 Conventional 2 zone control panelMF400 Conventional 4 zone control panelMF400-72 Conventional 4 zone control panel (72 hour standby)MAR424 Conventional fire and fault relay PCBMFALOG Fire alarm system log book

Product Codes

Code MF200 MF400

Description 2 zone control panel 4 zone control panel

Standards EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996

Specification

Number of Zones 2 4

Detectors per Zone 20 20

Number of Alarm Lines 2 2

Alarm Circuit Load 375mA per circuit. 750mA total 375mA per circuit. 750mA total

End of Line Devices Detection circuits: 22KΩ resistor Detection circuits: 22KΩ resistor

Alarm lines: 22KΩ resistor Alarm lines: 22KΩ resistor

Auxiliary Fire Signal Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA

Auxiliary Fault Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA

Auxiliary dc Output 24V dc fused. 32mA 24V dc fused. 32mA

(up to 100mA at the expense of alarm load) (up to 100mA at the expense of alarm load)

Mains Input Voltage 240V ac +10%-15% 240V ac +10%-15%

System Operating Voltage 24V dc 24V dc

Standby Duration 24 hours 24 hours (72 hours on MF400-72)

Battery 1 x 4Ah sealed lead acid battery 1 x 4Ah sealed lead acid battery

(1 x 7Ah on MF400-72)

Recharge Period 48 hours (80% in 24 hours) 48 hours (80% in 24 hours)

Environmental

Operating Temperature -5°C to +40°C -5°C to +40°C

Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH

Physical

Construction ABS/Polycarbonate housing. Steel back box. ABS/Polycarbonate housing. Steel back box.

Dimensions (H x W x D) 300mm x 300mm x 74mm 300mm x 300mm x 74mm

Weight 4.8kg 4.8kg (6.0kg on MF400-72)

Ingress Protection IP30 IP30

Cable entries Top: 10 x 20mm conduit entries Top: 10 x 20mm conduit entries

Bottom: 1 x 20mm conduit entry (mains cable) Bottom: 1 x 20mm conduit entry (mains cable)

Back: 1 x mains cable entry slot Back: 1 x mains cable entry slot

Technical Specification

Page 13: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Control Panels - MF200 and MF400

13

Installation1. A full set of Installation and user Instructions is

supplied with each panel to assist the installer to carry out the work efficiently and safely, and the user to perform routine tests.

2. Panels are wall mounted via keyhole slot mounting holes on back of housing.

3. Mains power supply cable must be routed via the designated 20mm conduit entry on the top or bottom of the housing, or via the rear cable entry slot. The mains terminal block is provided with fuseprotection.

4. A total of 10 x 20mm conduit entries are provided on the top of the housing for zone, alarm and output cables. Blanking plugs are supplied for un-used entries.

5. Standby battery connected via push-on terminal connectors.

6. End of line (EOL) devices are supplied with the panel and must be fitted at the end of each detector and alarm circuit wiring.

7. Front cover retained by anti-tamper screws.

System Functionality1. Normal and supervisor mode facility. Supervisor

mode protected by 4 digit security code to prevent unauthorised use.

2. Supervisor mode provides access to test mode, where zones can be tested individually.

3. One man walk test feature permits each manual callpoint and detector on the zone in test mode to be put into fire condition and activates the alarms for 2 seconds. Panel automatically resets the zone 10 seconds after each device has beentested. A fire condition received from a zone not in test mode results in an immediate alarm, overridingthe test mode.

4. Supervisor mode also provides facility to disable/isolate the following for maintenance or other purposes• each detection zone independently• the alarm circuits• the remote signal outputs

User Interface1. Attractive compact panel with easy to use 5 button

keyboard to control all functions2. Comprehensive power, fire and fault LED indicators

and integral piezo buzzer for on-board fire or fault indication

Interface Options1. Class change input facility. Terminals provided for

switching of alarm circuits to indicate school/college class change.

2. 24V dc outputs provided for remote signalling of fire and fault conditions.

3. Optional relay board available (MAR424) to convertfire and fault signals to volt free change over rated at 24V dc, 1A dc.

4. Auxiliary 24V dc output power supply provided as standard.

Detection Capacity1. Up to 20 detectors per zone. End of line monitoring

devices must be fitted and are supplied as standard.

2. Detector circuits are monitored for open circuit, short circuit and detector removal.

Alarm Capacity1. Two separate alarm lines, each with a maximum

rated load of 375mA.2. Alarm lines are monitored for open circuit and short

circuit faults.

Page 14: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

14

Conventional Control Panels - MF200 and MF400

ZONE1

ZONE4*

ZONE3*

ZONE2

+ - E

MDB800DETECTOR

BASE

MBG914/917CALLPOINT

connect as per instuctions

+ VE IN & OUT

ON 1

- VE IN & OUT

ON 2

END OF LINE22KOhm RESISTOR

subsequent

zones

END OF LINE22KOhm RESISTOR

+ - E + - E + - EALARM

2ALARM

1

+ - E + - E

subsequent alarm lines

REMSIG

AUXFAULT

+ - E + - E

FAU

LTS

IGN

AL

ISO

LATI

NG

FIR

E S

IGN

AL

MAR724MAR424

24V 10mA

AUXDC

CLASSCHANGE

+ - E + - E

SW

ITC

H /

CO

NTA

CTO

R/T

IME

R(A

PP

LY N

O V

OLT

AG

E)

24V

dc

AU

XIL

AR

Y S

UP

PO

RT

* MF400 ONLY

AUXFAULT

+ - EREMOTESIGNAL

+ - E

+ - E + -

C NC NO E E C NC NO

MAR424

AUXFAULT

REMOTESIGNAL

RELAY OUTPUTS24V 1A (resistive)

24V10mACOIL

24V10mACOIL

AUX FAULT /REMOTE SIGNAL

+ - E

24V dc 10mAPULL TO 0V

DOOR RELEASE UNITSRELAY OUTPUTS

240V dc 10A

AUX FAULT /REMOTE SIGNAL

+ - E

MAR724

NC C NO NO C NC

24V10mACOIL

+ -

C = COMMONNC = NOT NORMALLY CONNECTEDNO = NORMALLY OPEN

Standard Panel Connections

Page 15: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

15

Detectors

Overview

The Menvier range of conventional detectorshave been specifically designed to operate withMenvier control panels.

The Menvier optical detector MPD821 is suitable formost applications giving the fastest response to slowburning or smouldering fires which give rise to largevisible smoke particles.

The Menvier photo-thermal detector MPT951 willrespond quickly to fast clean burning fires yetmaintain the advantage of optical detectors whendetecting smouldering fires. The thermalenhancement of this detector allows a higher alarmthreshold which provides a greater rejection of falsealarms. The detector will also raise an alarm attemperatures exceeding 60ºC.

The Menvier fixed heat detectors MMT860 andMHT890 will detect temperatures above 77ºC and92ºC. The rate of rise heat detector MFR830 is usedto detect rapid increases in temperature with amaximum threshold of 60ºC.

These detectors are designed to be used inenvironments where the ambient conditions mightcause false alarms if smoke detection were to beused, for example where there is a high level of dust,fumes, steam or smoke under normal conditions.

innovative light pipe technology allows LED to beseen from any angle

Features• Quick and simple to install• Stylish low profile design• 360º viewable LED• Removable detector chamber• Drift compensation

Benefits• ‘Clean me’ feature means

detector can be cleaned onsite using the Menvier manualcleaning procedure

• Common mounting base• Positive ‘lock’ indication

optical / photo-thermal / heat detectors

Page 16: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

16

Conventional Detectors

Installation1. Detectors are fixed and wired via common

mounting base.2. Cable entry into base can be rear or side.3. A locking facility is provided which can be

activated if required to prevent unauthorised detector removal without the use of a special tool.

4. Positive click mechanism incorporated to provide clear indication when detector is correctly located in base.

Dimensions

Dia

D

Code DescriptionMPD821 Conventional optical smoke detectorMPT951 Conventional photo-thermal detectorMFR830 Conventional rate of rise heat detectorMMT860 Conventional fixed heat detector (77°C)MHT890 Conventional fixed heat detector (92°C)MDB800 Conventional detector baseMDP201 Duct Probe

Product Codes

Code MPD821 MPT951 MFR830 MMT860 MHT890

Description Optical smoke Detector Photo-thermal detector Rate of rise detector Fixed heat detector (77ºC) Fixed heat detector (92ºC)

Standards EN54 Pt7 2000, A1 2002 EN54 Pt 5 & Pt 7 2000, A1 2002 EN54 Pt 5 2000, A1 2002 EN54 Pt 5 2000, A1 2002 EN54 Pt 5 2000, A1 2002

Supply Ratings

Operating Voltage 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc

Standby Current 30µA (max) 30μA (max) 30μA (max) 30μA (max) 30μA (max)

Startup Current 340µA (max) 340μA (max) N/A N/A N/A

Alarm Current 25mA (max) 25mA (max) 25mA (max) 25mA (max) 25mA (max)

Fixing Information

Mounting Position Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas

Mounting Options Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base

Area Coverage 100m² (subject to local standards) 100m² (subject to local standards) 50m² (subject to local standards) 50m² (subject to local standards) 50m² (subject to local standards)

System Wiring 2 Core 2 Core 2 Core 2 Core 2 Core

Operation

Detection Mode Light scatter principle Light scatter principle & Heat sensitive element Heat sensitive element Heat sensitive element

Heat sensitive element

Heat Class N/A A2S A2R BS CS

Alarm Temperature N/A 60ºC 60ºC 77ºC 92ºC

Indication 360º visible LED 360º visible LED 360º visible LED 360º visible LED 360º visible LED

Environmental

Operating Temperature -20ºC to 60ºC -20ºC to 45ºC -20ºC to 45ºC -20ºC to 60ºC -20ºC to 75ºC

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH 0 to 93% RH 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS PC/ABS PC/ABS PC/ABS

Colour White White White White White

Dimensions Excl Base (Dia x H) 101mm x 33mm 101mm x 43mm 100mm x 43mm 101mm x 43mm 101mm x 43mm

Dimensions Incl Base (Dia x H) 101mm x 45mm 101mm x 55mm 100mm x 55mm 101mm x 55mm 101mm x 55mm

Ingress Protection IP40 IP40 IP40 IP40 IP40

EMC CE Marked CE Marked CE Marked CE Marked CE Marked

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems

Description Dia (mm) D (mm) D (mm)(excl base) (incl base)

Optical 101 33 45Photo-thermal 101 43 55Heat 101 43 55

User Interface1. Red LED to indicate alarm

condition.2. Amber LED to indicate

chamber fault/driftcompensation limit (enhanced versions only).

3. All wiring connections are via acommon mounting base (supplied separately).

Technical Specification

Note: For wiring information please see MDB800 base.

Page 17: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

17

Standard Base MDB800

Overview

The MDB800 Menvier conventional base has beenspecifically designed to be compatible with theMenvier range of conventional detectors.

This standard base has been designed for flexibility,simplicity and speed of installation.

It incorporates purpose designed devices to providefault warning if detector is removed whilstmaintaining full zone wiring integrity.

The base has a spring contact switch and a parallelzener diode to enable fault monitoring.

MPD821 optical detector

MPT951 photo-thermal detector

Features• Quick and simple to install• Separate zone in and zone out

terminals• Stand off fixing feature• Selectable detector locking

Benefits• Accepts side entry surface

cables• Common base for Menvier

conventional detectors

MFR830, MMT860, MHT890 heat detectors

MDB800 standard base

Suitable detectors for use withthe MDB800 standard base

Page 18: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

18

Conventional Standard Base - MDB800

Installation1. Base incorporates a retaining clip to provide

positive feedback when detector is correctly fitted.2. Separate terminals are provided for zone in and

zone out connections.3. Each terminal can accept up to 2 x 2.5mm cables4. Base incorporates a substantial cable entry

aperture in the rear of the base.5. Breakouts are provided to enable the detector

base to sit neatly over surface cables and then enter via the rear entry aperture.

6. Base mounting incorporates a stand off feature to help prevent distortion when mounted on an uneven surface.

7. Fixings are suitable for standard BESA box or direct fixing to suitable surface

8. Optional locking devices (supplied with base) to prevent unauthorised detector removal.

Dimensions

D

Dia

Dia (mm) D (mm)104 22

Code DescriptionMDB800 Conventional standard baseMDB800*10 Conventional standard base (pack of 10)CIR301 Conventional remote indicator

Product Codes

Standard Connection

WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact - use sleeves for end of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact.

Com

pat

ible

Men

vier

Con

vent

iona

lC

ontr

ol P

anel

+

-

ZO

NE

2

4

1

3

E

LED

+ VE

remote indicator (optional)+

- VE

2

4

1

3

E

LED

end

of l

ine

resi

stor

Code MDB800

Description Standard base

Physical

Construction PC/ABS

Colour White

Dimensions (Dia x D) 104mm x 22mm

Compatibility

Suitable for use with Menvier conventional detectors

Technical Specification

Interface Options1. Menvier conventional

detectors and bases support the use of a remote LED (optional extra CIR301).

Page 19: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

19

Relay Base MDB800R

Overview

The MDB800R Menvier conventional relay base hasbeen specifically designed to be compatible withthe Menvier range of conventional detectors.

This relay base as been designed for flexibility,simplicity and speed of installation.

It provides a local relay signal in the event of its hostdetector being triggered, making it ideal forinstigating a local response.

Features• Quick and simple to install• Designed specifically for use

with Menvier detectors• Provides remote signal for

external interfacing

Benefits• First fix mounting plate for

ease of installation• Local control output from host

detector

MDB800R relay base

Suitable detectors for use withthe MDB800R relay base

MPD821 optical detector

MPT951 photo-thermal detector

MFR830, MMT860, MHT890 heat detectors

Page 20: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

20

Conventional Relay Base - MDB800R

Installation1. Relay base is supplied with a first fix fixing plate.2. Fixing plate has a central cable aperture.3. Cable entry is from rear.4. Main body is then clipped into place on base, body

locks into place when pressed into position.

System Functionality1. Relay is controlled by status of host detector.2. If host detector is triggered relay activates.

Dimensions

D

Dia

Dia (mm) D (mm)102 40

Code DescriptionMDB800R Conventional relay base

Product Codes

Code MDB800R

Description Relay base

Specification

Relay Contact Rating 1A at 24V dc

Relay Trigger Source Detector remote LED output

Detector Locking Facility Supplied as standard

Physical

Construction PC/ABS

Colour White

Dimensions (Dia x D) 102mm x 40mm

Compatibility

Suitable for use with Menvier conventional detectors

Technical Specification

Interface Options1. Bases are compatible with

latest generation conventional Menvier detectors.

Standard Connection

WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact - use sleeves for end of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact.

Com

pat

ible

Men

vier

Con

vent

iona

lC

ontr

ol P

anel

+

-

ZO

NE

2

4

1

3

E

LED

+ VE

remote indicator (optional)+

- VE

end

of l

ine

resi

stor

2

4

1

3

E

LED

Page 21: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

21

Remote Indicator CIR301

Overview

The CIR301 conventional remote indicator isdesigned to provide discreet remote indication foruse with Menvier conventional detectors.

The remote indicator is ideal for applications such asvoid spaces or outside locked or inaccessible roomsto provide indication of the activation of an automaticdetector.

Features• Quick and simple to install• Wide viewing angle high

brightness LED• Attractive styling

Benefits• High profile LED• Fits onto standard single gang

back box

CIR301 remote indicator

Page 22: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

22

Conventional Remote Indicator - CIR301

Code CIR301

Description Remote indicator

Environmental

Operating Temperature -10°C to +55°C

Humidity (Non Condensing) 0 to 95% RH

Physical

Construction ABS

Colour White

Lens Colour Red

Dimensions (H x W x D) 87mm x 87mm x 30mm

Weight 0.28kg

Ingress Protection IP30

Compatibility

Suitable for use with Menvier conventional fire systems

Technical Specification

Installation1. Mounting plate fixes to single gang back box or

can be direct fixed to wall or ceiling.2. Cable entry is normally from rear but breakouts are

provided in side of base plate.3. Cables connect to terminals on PCB within base

plate.4. Front cover is pushed onto base plate and locks in

place.

DimensionsD

H

W

H (mm) W (mm) D (mm)87 87 30

System Functionality1. The remote indicator is

connected to an individual detector.

2. The remote indicator activates if detector is triggered.

3. LED cancels when detector is reset.

4. Low current consumption.

Code DescriptionCIR301 Conventional remote indicatorM1R195B Conventional remote indicator (with buzzer)

Product Codes

Terminal block unplugs for ease of connection

Standard Connection

Com

pat

ible

Men

vier

Con

vent

iona

lC

ontr

ol P

anel

+

-

ZO

NE

2

4

1

3

E

LED

+ VE

remote indicator (optional)+

- VE

CIR301

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

DE

TEC

TOR

BA

SECompatible

Menvier Conventional Control Panel

+ -

IN

Page 23: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

23

Reflective Beam Detectors MBD50R and MBD100R

Overview

The Menvier range of zone powered reflective beamdetectors are specifically designed to be compatiblewith the full range of conventional Menvier controlpanels.

Two versions are available, the MBD50R with a rangeof up to 50 metres, and the MBD100R with a range of50 - 100 metres.

Both of these units are extremely simple to install, theyrequire no separate power supply, operate on areflective principle and have a simple set up mode toenable easy and quick alignment during installation.

Beam detectors are designed to replace individualpoint detectors in large open areas such aswarehouses.

Fire and fault conditions are signalled to panel usingstandard zone wiring so no additional interconnectionis required.

In normal operation only one beam detector may beconnected per zone, however special versions areavailable to work with external power supply if multiplebeam detectors are required to be connected to asingle zone.

combined transmitter and receiver for ease ofinstallation

optional mounting bracket with cable clamp facilities

Features• Quick and simple to install• Simple two wire connection• No power supply required

Benefits• Single device to install instead

of numerous point detectors• Single point of maintenance• Wall mounted for ease of

maintenance

MBD50R and MBD100R reflective beam detectors

Page 24: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

24

Conventional Reflective Beam Detector - MBD50R and MBD100R

Dimensions

H D

W

H (mm) W (mm) D (mm)210 130 120

Code DescriptionMBD50R Conventional reflective beam detector, 50m rangeMBD100R Conventional reflective beam detector, 100m rangeMRBFP Mounting bracket

Product Codes

Code MBD50R MBD100R

Description Reflective beam detector Reflective beam detector

Standards EN54 Pt 12 2002 EN54 Pt 12 2002

Specification

Operating Voltage 18V dc to 30V dc 18V dc to 30V dc

Quiescent Current <5mA (no LED’s illuminated) <5mA (no LED’s illuminated)

Alarm Current <9mA <9mA

Alignment Current <18mA <18mA

Power up Time 20 seconds (approx) 20 seconds (approx)

Operating Range 5 to 50 metres 50 to 100 metres

Tolerance to Beam

Misalignment at 35% Detector ± 0.8°, Prism ± 5.0° Detector ± 0.8°, Prism ± 5.0°

Fire Alarm Thresholds 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 2.50dB (25%) 3.74dB (35%) 6.02dB (50%)

Optical Wavelength 880nm 880nm

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour White White

Dimensions (H x W x D) 210mm 130mm x 120mm 210mm 130mm x 120mm

Weight 0.8kg 0.8kg

Ingress Protection IP40 IP40

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical Specification

Installation1. Must be fixed to solid structure.2. Recommended mounting height is 0.3 to 0.6

metres below the ceiling.3. Only 1 conventional reflective beam allowed per

control panel zone, if multiple beams per zone required, special externally powered version available.

4. Cables can be terminated into separate terminationbox (not supplied) or use purpose designed mounting bracket (MRBFP) ordered separately.

5. Mounting bracket has facilities for glanding of incoming cables plus simple fixing of beam detector.

6. Test filter is supplied with detector to simulate required smoke obscuration level and confirm correct operation.

System Functionality1. Beam detectors have 3 modes

• Prism targeting modedesigned to provide simple initial alignment of beam andreflector assembly.

• Alignment mode Enables accurate fine tuningof beam alignment without the need for additional calibration equipment or a second operator.

• Normal running mode

User Interface1. Beam detector status LEDs

• Red LED constantly illuminated indicates fire condition.

• Flashing amber LED indicates fault condition.

Interface Options1. Conventional beam detectors

are connected directly to the Menvier conventional panel.

Standard Connection

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of zone.

ZO

NE

IN

EOLDEVICE

CompatibleMenvier Conventional

Control Panel

+ -

IN

to beam detector socket

+ -

MBD50R / MBD100R

Page 25: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

25

Callpoints MBG914 and MBG917

Overview

This attractively designed, simple to install, range ofcallpoints have been specifically developed to becompatible with Menvier conventional fire panels.

There are 2 versions of callpoint in this range. TheMBG914 which can be either surface or flushmounted and the MBG917 which is a weatherproofversion.

All callpoints are supplied as standard with afrangible glass element and a test key for ease ofmaintenance.

A comprehensive range of accessories are availableto maximise the functionality of the callpoint forparticular applications.

MBGHCC protective hinged cover

Features• High visibility status LED • Standard and weatherproof

versions available• Wide range of accessories • Heavy duty terminals

Benefits• Quick and simple to install• Fast fit clip on front cover• Single tool for test and access

MBG917 weatherproof callpoint

MBG914 callpoint

MBGBEZ recessing bezel

Page 26: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

26

Conventional Callpoints - MBG914 and MBG917

Installation1. Surface callpoint has standard rear BESA fixing

facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted.

2. Callpoint has test facility via special test key to prevent unauthorised operation.

3. Insertion of test key for test purposes and for coverremoval is at bottom of callpoint to facilitate ease of access when mounted next to door architrave.

4. Test key is dual function, used to test callpoint operation by simulating activation and also to allowremoval of clip on cover to gain access to element.

5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key).

6. Separate zone in and zone out terminals are provided for all connections.

7. Surface/flush callpoints are IP42, weatherproof is IP65.

User Interface1. To enable quick and simple installation, callpoints

use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied).

2. Callpoint is triggered by pressing against the element.

Code DescriptionMBG914 Conventional surface/flush callpointMBG917 Conventional weatherproof callpointMBGHCC Protective hinged coverMBGSP Spacer plates (pack of 10)MBGBEZ Recessing bezels (pack of 10)MBGREKIT Resettable element kit (pack of 10)MBG118 Spare break glasses (pack of 5)MBG119 Earth continuity links (pack of 5)MFBGKEY3 Callpoint keys (pack of 10)

Product Codes

Accessories• Semi recess bezel• Spacer plates• Hinged clear cover• Resettable plastic element• Replacement test key• Replacement glass elements• Earth continuity links

Code MBG914 MBG917

Description Surface/flush mount callpoint Weatherproof callpoint

Standards EN54 Pt11 EN54 Pt11

Specification

Operating Voltage 18V dc to 30V dc 18V dc to 30V dc

Environmental

Operating Temperature -10°C to +55°C -25°C to +70°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Dimensions (H x W x D) 87mm x 87mm x 57mm (36mm flush) 87mm x 87mm x 59mm

Weight 0.2kg 0.2kg

Ingress Protection IP42 IP65

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical SpecificationDimensions

D

H

W

Description H (mm) W (mm) D (mm)Flush mounted 87 87 36Surface mounted 87 87 57Weatherproof 87 87 59

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:470Ω connection is for standard Menvier conventional panels.

4V7 connection can be used with MF9300 to enable certain

features on the Menvier MF9300 range of control panels.

-+ -

CO

MM

ON

470Ω

4V7

+ - -

MBG914 / MBG917

Page 27: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

27

Bells MBM246, MBM248 and MWB824

Overview

Bells still remain a popular choice for manyapplications such as schools where they cansometimes be used as a signal for non firepurposes such as class change.

MBM246 and MBM248The MBM246 and MBM248 Menvier internal bellsincorporate highly efficient rotary centrifugalmovements combining high sound output with lowcurrent consumption.

MWB824The MWB824 Menvier weatherproof bell enables acommon bell sound to be achieved throughout acomplete site, including areas where a weatherproofdevice is required.

MWB824 weatherproof bell

Features• Quick and simple to install• High sound output• Low current consumption• Multi-fixing base plate (internal)• IP42 rated (internal)• IP54 rated (weatherproof)

Benefits • Can be used for non fire

applications

MBM246 and MBM248 internal bells

Page 28: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Code MBM246 MBM248 MWB824

Description Internal 6 Inch bell Internal 8 Inch bell Weatherproof 8 Inch bell

Standards EN54 Pt3 EN54 Pt3 EN54 Pt3

Specification

Operating Voltage 24V dc 24V dc 24V dc

Current Consumption 25mA at 24V dc 28mA at 24V dc 28mA at 24V dc

Sound Output 93-95dB(A) at 24V dc 95-97dB(A) at 24V dc 95dB(A) (+/-2)

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH 0 to 93% RH

Physical

Construction gong - steel / base-polycarbonate gong - steel / base-polycarbonate stove enamelled

Colour Red Red Red

Dimensions (Dia x D) 152mm x 63mm 203mm x 67mm 200mm x 104mm

Weight 0.85kg 1.7kg 0.49kg

Ingress Protection IP21C IP21C IP54

Cable Entry Rear Rear Via separate back box

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems

28

Conventional Bells - MBM246, MBM248 and MWB824

Installation

MBM246 / MBM2481. Multiple rear fixing options, can be fixed direct to

wall or mounted on suitable BESA box.2. Cable entry into bell is from rear.3. Incorporates heavy duty terminals suitable for

2.5mm cables.

MWB8241. Supplied with heavy duty gasketed back box

which supports bottom entry cables.2. Incorporates heavy duty terminals.

Code DescriptionMBM246 Conventional internal 6 Inch bellMBM248 Conventional internal 8 Inch bellMWB824 Conventional weatherproof 8 Inch bell

Product Codes

Technical Specification

Device Functionality

MBM246 / MBM2481. Sound output is fixed and

determined by size of the bell.2. Operation is driven by an

internal motor and strikerarrangement.

3. Bells are polarised and suppressed.

MWB8241. Bell operates via solenoid.2. Bell is polarised and

suppressed.

DimensionsD

Dia

Description Dia (mm) D (mm)6 inch internal bell 152 638 inch internal bell 203 678 inch weatherproof bell 200 104

Dia

D

Internal bell Weatherproof bell

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

- ++-

MBM246 / MBM248 / MBM824

Page 29: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

29

Flush Sounders MFS324 and MFS324W

Overview

The Menvier discreet flush sounder is designed tobe compatible with Menvier conventional firesystems. Available in a choice of colours MFS324red and MFS324W white.

These flush sounders provide an excellentcombination of high sound output and discreetappearance. Ideal for retail, hotel and residentialapplications such as sheltered housing.

Features• Choice of colours• Separate volume control• Choice of tone is determined

by selection of appropriateterminal for negative connection

Benefits• Quick and simple to install• Low profile design

MFS324W white flush sounder

MFS324 red flush sounder

Page 30: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

30

Conventional Flush Sounder - MFS324 and MFS324W

Installation1. Sounder fixes to a single gang deep back box.2. Fixing screws included.3. Connections are to main sounder body.4. Separate loop in and loop out terminals are

provided.5. For surface mount applications a separate red

single gang box can be ordered separately.

Dimensions

D

W

H

H (mm) W (mm) D (mm)86 86 36

Code DescriptionMFS324 Conventional flush sounder, redMFS324W Conventional flush sounder, whiteMFSSBB Back box, red

Product Codes

Interface Options1. Operates from nominal 24V dc

supply and can be connected to any suitably rated conventional sounder circuit.

Code MFS324 MFS324W

Description Flush sounder Flush sounder

Standards EN54 Pt3 EN54 Pt3

Specification

Operating Voltage 6V dc to 28V dc 6V dc to 28V dc

Current Consumption 20mA at 24V dc 20mA at 24V dc

Sound Output 98dB(a) at 1 Metre (+/- 2) 98dB(a) at 1 Metre (+/- 2)

Environmental

Operating Temperature -25ºC to +55ºC -25ºC to +55ºC

Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH

Physical

Construction ABS ABS

Colour Red White

Dimensions (H x W x D) 86mm x 86mm x 36mm 86mm x 86mm x 36mm

Weight 0.3kg 0.3kg

Ingress Protection IP20 IP20

Cable Entry Via separate back box Via separate back box

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical Specification

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

-+ -

CO

MM

ON

1st

SO

UN

D

2nd

SO

UN

D

+ - -

MFS324 / MFS324W

Page 31: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

31

Overview

The Menvier base mountable sounder and sounderbeacon have a slim and aesthetically pleasingdesign and can be installed as either as a discreetstand alone sounder / sounder beacon or ceilingmounted as shown, with detector and base.

When mounted with a detector and base it simplifiesthe installation of the system by enabling a detectorand sounder to be fixed at a single common point.

When used as a stand alone sounder the device canbe either wall or ceiling mounted and completed withan optional cover plate (MDS824COV).

The sounder is ideal for applications such as hotelbedrooms or where a detector sounder / sounderbeacon is required.

Features• Quick and simple to install• Low profile design• Discreet appearance• Blanking plate available when

used as a stand alone sounder

Benefits• Single installation point• Can be wired as a stand alone

unit

MDS824B sounder beacon with conventionaldetector and base

MDS824 base mountable sounder

MDS824B sounder beacon with blanking plate(MDS824COV)

Sounder and Sounder Beacon MDS824 and MDS824B

Page 32: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

32

Sounder and Sounder Beacon - MDS824 and MDS824B

Installation1. Sounder/beacon fixes to mounting surface.2. Cables pass through the middle of the sounder.3. Sounder/beacon wiring terminates at the sounder

terminals.4. Detector wiring terminates at normal connections

on detector base.5. If no detector is to be fitted, a blanking plate can

be fitted instead.

Code DescriptionMDS824 Conventional sounderMDS824B Conventional sounder beaconMDS824COV Blanking plate (pack of 5)

Product Codes

Code MDS824 MDS824B

Description Sounder Sounder beacon

Standards EN54 Pt3 EN54 Pt3

Specification

Operating Voltage 10V dc to 28V dc 10V dc to 28V dc

Current Consumption 5mA (low) 7 ma (high) at 24V 7mA (low) 10 ma (high) at 24V

Sound Output 80/90dB(a) (+/-3) @ 1 Metre 80/90dB(a) (+/-3) @ 1 Metre

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction ABS ABS

Colour White White

Dimensions (Dia x D) 111mm x 26mm 111mm x 26mm

Weight 0.4kg 0.4kg

Ingress Protection IP30 IP30

Cable Entry Rear Rear

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical SpecificationDimensionsDia

D

Dia (mm) D (mm)111 26

Interface Options1. Operates from nominal 24V dc

supply and can be connected to any suitably rated conventional sounder circuit.

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

--

1st

SO

UN

D

2nd

SO

UN

D

+

CO

MM

ON

+--

MDS824 / MDS824B

Page 33: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

33

Surface Sounders MWS424SB and MWS424DB

Overview

These general purpose conventional surfacesounders have been specifically designed to workwith Menvier conventional control panels.

MWS424SBThe MWS424SB is a low profile surface sounder.

Volume is adjustable via the internal volume controland 32 different alarm tone selections are provided.

Depending on the selected tone, sound levels of upto 105dB(A) can be achieved.

MWS424DBThe MWS424DB is a weatherproof (IP65) surfacesounder.

Volume is adjustable via the internal volume controland 32 different alarm tone selections are provided.

Depending on the selected tone, sound levels of upto 105dB(A) can be achieved.

low profile base

weatherproof base

Features

MWS424SB• Low profile design• Pre drilled cable entries• 32 selectable tones

MWS424DB• Weatherproof version (IP65)• Choice of cable entry positions• 32 selectable tones

Benefits• Low current, high sound

output• Suitable for a wide range of

applications• Automatic synchronisation

MWS424DB weatherproof surface sounder MWS424SB low profile surface sounder

Page 34: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

34

Conventional Surface Sounders - MWS424SB and MWS424DB

Installation

MWS424SB1. Supplied with simple to install first fix mounting

base.2. Fixing and cable entry holes are pre-drilled.3. Cable entry is from rear.4. Connections are to main sounder body.5. Separate zone in and zone out terminals are

provided.6. Main body is pushed into sounder base and then

twisted to lock into place.

MWS424DB1. Supplied with simple to install first fix mounting

base.2. To maintain weatherproof integrity, fixing holes are

drilled upon installation.3. Cable entry can be rear or side.4. Connections are to main sounder body.5. Separate zone in and zone out terminals are

provided.6. Main sounder body is pushed into mounting base

and twisted to lock.

Code DescriptionMWS424SB Conventional low profile surface sounderMWS424DB Conventional weatherproof surface sounder

Product Codes

Interface Options

MWS424SB / MWS424DB1. Operates from nominal 24V dc

supply and can be connected to any suitably rated conventional sounder circuit.

Options

MWS424SB / MWS424DB1. Choice of tone setting (set via

DIP switches can be altered atany time).

DimensionsD

Dia

Description Dia (mm) D (mm)Low profile surface sounder 93 63Weatherproof surface sounder 93 93

D

Dia

Low profile surface sounder

Weatherproof surface sounder

Code MWS424SB MWS424DB

Description Low profile surface sounder Weatherproof surface sounder

Standards EN54 Pt3 EN54 Pt3

Specification

Operating Voltage 9V dc to 28V dc 9V dc to 28V dc

Current Consumption 16mA at 24V dc 16mA at 24V dc

Sound Output 105dB(a) max (+/-2) at 24V dc 105dB(a) max (+/-2) at 24V dc

Number of Tones 32 32

Environmental

Operating Temperature -25°C to +70°C -25°C to +70°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Dimensions (Dia x D) 93mm x 63mm 93mm x 93mm

Weight 0.24kg 0.3kg

Ingress Protection IP54 IP65

Cable Entry Rear Rear/side

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical Specification

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

-+ -

CO

MM

ON

1st

SO

UN

D

2nd

SO

UN

D

+ - -

MWS424SB / MWS424DB

Page 35: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

35

Low Current Sounder MLC624

Overview

The MLC624 Menvier low current sounder has beendesigned to provide a high sound output with a lowcurrent consumption.

It is ideal for applications where high sound levelsneed to be achieved but where available soundercircuit capacity is limited.

The low current sounder is simple to install and usesa first fix back plate onto which the main bodyattaches with a self locking press fix assembly.

Features• Quick and simple to install• Low current consumption• High efficiency design• 3 different tones• Separate volume control

Benefits• Low current, high sound

output• Automatic synchronisation• Self locking assembly

MLC624 low current sounder

Page 36: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

36

Conventional Low Current - MLC624

Installation1. First fix mounting plate is fixed to wall.2. Cable entry is from rear, or top/bottom.3. Connections are to main sounder body.4. Separate alarm line in / out terminals are provided.

Code DescriptionMLC624 Conventional low current sounder

Product Codes

Dimensions

Interface Options1. Operates from nominal 24V dc

supply and can be connected to any suitably rated conventional sounder circuit.

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

-+ -

CO

MM

ON

1st

SO

UN

D

2nd

SO

UN

D

+ - -

MLC624

Code MLC624

Description Low current sounder

Standards EN54 Pt3

Specification

Operating Voltage 12V dc to 30V dc

Current Consumption 5mA at 24V dc

Sound Output 100dB(a) at 24V dc

Environmental

Operating Temperature -25°C to +70°C

Humidity (Non Condensing) 0 to 93% RH

Physical

Construction PC/ABS

Colour Red

Dimensions (H x W x D) 105mm x 105mm x 95mm

Weight 0.25kg

Ingress Protection IP42

Cable Entry Rear or top/bottom

Compatibility

Suitable for use with Menvier conventional fire systems

Technical Specification

D

H

W

H (mm) W (mm) D (mm)105 105 95

Page 37: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

37

Xenon Beacons MXB124SB and MXB124DB

Overview

This range of Menvier xenon beacons is available tocomplement purely audible alarms for use in areaseither where people may be present who haveimpaired hearing or areas with high ambient noiselevels.

Xenon beacons have a high light output to maximisethe attention attracting potential of the device.

MXB124SBThe MXB124SB low profile xenon beacon features ahigh performance light source. Pre-drilled fixing andcable entry holes it is simple to install.

MXB124DB The MXB124DB weatherproof xenon beacon isIP65 rated and supports side entry surface cablesmaking it ideal for industrial applications.

Lower power LED variants are also available whichoffer a lower current consumption but have aconsequently lower light output than traditional xenontypes (MLB124SB and MLB124DB LED beacons).

low profile base

weatherproof base

FeaturesMXB124SB • Unobtrusive low profile design• High output xenon beacon• Pre drilled cable entries

entry holes

MXB124DB • Weatherproof version (IP65)• High output xenon beacon• Choice of cable entry positions

Benefits• first fix base• Compatible with range of

Menvier fire detection panels• Weatherproof version

MXB124DB weatherproof xenon beacon MXB124SB low profile xenon beacon

Page 38: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

38

Conventional Xenon Beacons - MXB124SB and MXB124DB

Installation

MXB124SB1. Supplied with simple to install first fix mounting

base.2. Fixing and cable entry holes are pre-drilled.3. Cable entry is from rear.4. Connections are to main beacon body.5. Separate alarm line in / out terminals are

provided.6. Main body is pushed into sounder base and then

twisted to lock into place.

MXB124DB1. Supplied with simple to install first fix mounting

base.2. Cable entry is from rear or side.3. Connections are to main beacon body.4. Separate alarm line in / out terminals are

provided.5. Main body is pushed into sounder base and then

twisted to lock into place.

Code DescriptionMXB124SB Conventional low profile xenon beacon, 1 WattMXB124DB Conventional weatherproof xenon beacon, 1 WattMXB224SB Conventional low profile xenon beacon, 2 WattMXB224DB Conventional weatherproof xenon beacon, 2 Watt

Product Codes

Interface Options

MXB124SB / MXB124DB1. Operates from nominal 24V dc

supply and can be connected to any suitably rated conventional sounder circuit.

Dimensions

D

Dia

Description Dia (mm) D (mm)Low profile xenon beacon 93 72Weatherproof xenon beacon 93 101

D

Dia

Low profile xenon beacon

Weatherproof xenon beacon

Code MXB124SB MXB124DB

Description Low profile xenon beacon Weatherproof xenon beacon

Specification

Operating Voltage 24V dc 24V dc

Current Consumption 45mA at 24V dc 45mA at 24V dc

Operation Continuous Continuous

Flash Energy 1.45J 1.45J

Flash Frequency 60 per minute 60 per minute

Environmental

Operating Temperature -20°C to +55°C -20°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93 RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Lens Colour Red Red

Dimensions (Dia x D) 93mm x 72mm 93mm x 101mm

Weight 0.2kg 0.25kg

Ingress Protection IP54 IP65

Cable Entry Rear Rear/side

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical Specification

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

-++ -

MXB124SB / MXB124DB

Page 39: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

39

Xenon Sounder Beacons MCD524SB and MCD524DB

Overview

This range of Menvier xenon sounder beacons isavailable to complement purely audible alarms foruse in areas either where people may be presentwho have impaired hearing or areas with highambient noise levels.

The key benefit of these devices is that an audibleand a visual alarm are combined together and requireonly a single installation point. This greatly reducesinstallation time and cost and is much less obtrusivethan 2 separate devices. Xenon beacons have a highlight output to maximise the attention attractingpotential of the device.

MCD524SBThe MCD524SB low profile xenon sounder beaconfeatures a high performance light source andadjustable volume control. Due to predrilled fixingand cable entry holes it is simple to install.

MCD524DBThe MCD524DB weatherproof xenon sounderbeacon is IP65 rated and features a high performancelight source and adjustable volume control.

Lower power LED variants are also available whichoffer a lower current consumption but have aconsequently lower light output than traditional xenontypes (MSB124SB and MSB124DB LED sounderbeacons).

low profile base

weatherproof base

Features

MCD524SB• Unobtrusive low profile design• High output xenon beacon• Pre drilled cable entries• Sounder and beacon with a

single installation point• 32 selectable tones

MCD524DB • Weatherproof version (IP65)• High output xenon beacon• Side entry surface cables• Sounder and beacon with a

single installation point• 32 selectable tones

Benefits• Combined audio / visual unit• Single installation point

MCD524DB weatherproof xenon sounder beacon MCD524SB low profile xenon sounder beacon

Page 40: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

40

Conventional Xenon Sounder Beacons - MCD524SB and MCD524DB

Installation

MCD524SB1. Supplied with simple to install first fix mounting

base.2. Fixing and cable entry holes are pre-drilled.3. Cable entry is from rear.4. Connections are to main beacon body.5. Separate alarm line in / out terminals are

provided.6. Main body is pushed into sounder base and then

twisted to lock into place.7. Supply is common for sounder and beacon

MCD524DB1. Cable entry is from rear or side.2. Connections are to main beacon body.3. Separate alarm line in / out terminals are

provided.4. Main body is pushed into sounder base and then

twisted to lock into place.5. Supply is common for sounder and beacon

Code DescriptionMCD524SB Conventional low profile xenon sounder beaconMCD524DB Conventional weatherproof xenon sounder beacon

Product Codes

Interface Options

MCD524SB / MCD524DB1. Operates from nominal 24V dc

supply and can be connected to any suitably rated conventional sounder circuit.

DimensionsD

Dia

Description Dia (mm) D (mm)Low profile xenon sounder beacon 93 92Weatherproof xenon sounder beacon 93 121

D

Dia

Low profile xenon sounder beacon

Weatherproof xenon sounder beacon

Code MCD524SB MCD524DB

Description Low profile xenon sounder beacon Weatherproof xenon sounder beacon

Specification

Operating Voltage 18V dc to 30V dc 18V dc to 30V dc

Current Consumption 68mA (av) 73mA (peak) 68mA (av) 73mA (peak)

Operation Continuous Continuous

Flash Energy 0.7J 0.7J

Flash Frequency 60 per minute 60 per minute

Sound Output 101dB(a) max (+/-3) at 24V dc 101dB(a) max (+/-3) at 24V dc

Number of Tones 32 32

Environmental

Operating Temperature -20°C to +55°C -20°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Lens Colour Red Red

Dimensions (Dia x D) 93mm x 92mm 93mm x 121mm

Weight 0.25kg 0.33kg

Ingress Protection IP54 IP65

Cable Entry Rear Rear/side

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical Specification

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

- +-

CO

MM

ON

1st

SO

UN

D

2nd

SO

UN

D

+--

MCD524SB / MCD524DB

Page 41: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

41

LED Beacons MLB124SB and MLB124DB

Overview

This range of Menvier LED beacons is available tocomplement audible alarms for use in areas eitherwhere people may be present who have impairedhearing or areas with high ambient noise levels.

LED technology offers a greatly reduced currentconsumption compared to xenon types making themideal for use with fire panels with restricted soundercircuit current capacity.

MLB124SBThe MLB124SB low profile LED beacon is simple toinstall, and offers a reduced depth with pre-drilledfixing and cable entry holes, suitable for both wall orceiling mounting. This beacon utilises 18 carefullypositioned LED's to provide a high intensity output.Both output intensity and flash frequency isselectable using internal DIP switch.

MLB124DBThe MLB124DB weatherproof LED beacon is IP65rated making them ideal for industrial applications.This beacon utilises 18 carefully positioned LED's toprovide a high intensity output. Both output intensityand flash frequency is selectable using internal DIPswitch.

low profile base

weatherproof base

Features

MLB124SB• Unobtrusive low profile design• Low power consumption LED’s• Choice of flash frequency • Choice of power settings• Pre drilled cable entries

MLB124DB• Weatherproof version (IP65)• Low power consumption LED’s • Choice of flash frequency• Choice of power settings• Choice of cable entry positions

Benefits• Low power requirement • Selectable flash frequency• Selectable flash intensity

MLB124DB weatherproof LED beacon MLB124SB low profile LED beacon

Page 42: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

42

Conventional LED Beacons - MLB124SB and MLB124DB

Installation

MLB124SB1. Supplied with simple to install first fix mounting

base.2. Fixing and cable entry holes are pre-drilled.3. Cable entry is from rear.4. Connections are to main beacon body.5. Separate alarm line in / out terminals are

provided.6. Main body is pushed into base and then twisted to

lock into place.

MLB124DB1. Supplied with simple to install first fix mounting

base.2. Cable entry is from rear or side.3. Connections are to main beacon body.4. Separate alarm line in / out terminals are

provided.5. Main body is pushed into base and then twisted to

lock into place.

Code DescriptionMLB124SB Conventional low profile LED beaconMLB124DB Conventional weatherproof LED beacon

Product Codes

Interface Options

MLB124SB / MLB124DB1. Operates from nominal 24V dc

supply and can be connected to any suitably rated conventional sounder circuit.

Dimensions

Description Dia (mm) D (mm)Low profile LED beacon 95 53Weatherproof LED beacon 95 80

D

Dia

Low profile LED beacon

Weatherproof LED beacon

Code MLB124SB MLB124DB

Description Low profile LED beacon Weatherproof LED beacon

Specification

Operating Voltage 18V dc to 30V dc 18V dc to 30V dc

Current Consumption 3 to 6mA at 24V dc (depending on power setting) 3 to 6mA at 24V dc (depending on power setting)

Flash Frequency 30 or 60 per minute (selectable) 30 or 60 per minute (selectable)

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Lens Colour Red Red

Dimensions (Dia x D) 95mm x 53mm 95mm x 80mm

Weight 0.1kg 0.15kg

Ingress Protection IP54 IP65

Cable Entry Rear Rear/side

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical Specification

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

-++ -

MLB124SB / MLB124DB

D

Dia

Page 43: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

43

LED Sounder Beacon MSB124SB and MSB124DB

Overview

This range of Menvier LED sounder beacons isavailable to complement purely audible alarms foruse in areas either where people may be presentwho have impaired hearing or areas with highambient noise levels.

LED technology offers a greatly reduced currentconsumption compared to xenon types making themideal for use with fire panels with restricted soundercircuit current capacity.

MSB124SBThe MSB124SB low profile LED sounder beaconfeatures a low current LED light source andadjustable volume control. Choice of tones can beselected via the DIP switch. With predrilled fixing andcable entry holes it is simple to install.

MSB124DBThe MSB124DB weatherproof LED sounder beaconis IP65 rated and features a low current LED lightsource and adjustable volume control.

low profile base

weatherproof base

Features

MSB124SB• Unobtrusive low profile design• Low current LED beacon• Sounder and beacon with a

single installation point• Pre-drilled fixing and cable

entry holes• 32 selectable tones

MSB124DB• Weatherproof version (IP65)• Low current LED beacon• Sounder and beacon with a

single installation point• Choice of cable entry positions• 32 selectable tones

Benefits• Low power requirement• Adjustable sounder volume• Selectable tones

MSB124DB weatherproof LED sounder beacon MSB124SB low profile LED sounder beacon

Page 44: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

44

Conventional LED Sounder Beacon - MSB124SB and MSB124DB

Installation

MSB124SB1. Supplied with simple to install first fix mounting

base.2. Fixing and cable entry holes are pre-drilled.3. Cable entry is from rear.4. Connections are to main beacon body.5. Separate alarm line in / out terminals are

provided.6. Main body is pushed into sounder base and then

twisted to lock into place.7. Supply is common for sounder and beacon

MSB124DB1. Cable entry is from rear or side.2. Connections are to main beacon body.3. Separate alarm line in / out terminals are

provided.4. Main body is pushed into base and then twisted to

lock into place.5. Supply is common for sounder and beacon

Code DescriptionMSB124SB Conventional low profile LED sounder beaconMSB124DB Conventional weatherproof LED sounder beacon

Product Codes

DimensionsDia

D

Description Dia (mm) D (mm)Low profile LED sounder beacon 93 80Weatherproof LED sounder beacon 95 109

Dia

D

Low profile LED sounder beacon

Weatherproof LED sounder beacon

Code MSB124SB MSB124DB

Description Low profile LED sounder beacon Weatherproof LED sounder beacon

Standards EN54 Pt3 EN54 Pt3

Specification

Operating Voltage 9V dc to 28V dc 9V dc to 28V dc

Current Consumption 20mA at tone 3 20mA at tone 3

Operation Continuous Continuous

Flash Frequency 60 per minute 60 per minute

Number of Tones 32 32

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Lens Colour Red Red

Dimensions (Dia x D) 93mm x 80mm 95mm x 109mm

Weight 0.25kg 0.3kg

Ingress Protection IP54 IP65

Cable Entry Rear Rear/side

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical Specification

Interface Options

MSB124SB / MSB124DB1. Operates from nominal 24V dc

supply and can be connected to any suitably rated conventional sounder circuit.

.

Standard Connection

CompatibleMenvier Conventional

Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

-+ -

CO

MM

ON

1st

SO

UN

D

2nd

SO

UN

D

+ - -

MSB124SB / MSB124DB

Page 45: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Conventional Product Range

45

Heavy Duty Door Retainers MDR240 and MDR24L

Overview

This range of Menvier heavy duty magnetic doorretainers are robust and simple to install, makingthem ideal for a wide range of applications, such asnursing homes, hospitals, schools and industrialpremises.

Two versions are available, the mains poweredMDR240 which has a holding force of 40kg and theMDR24L 24V dc powered also with a holding force of40kg

Both versions enable doors to be held open undernormal conditions but to be automatically released inthe event of fire alarm activation.

Their die cast aluminium construction with plasticfront cover plate make them suitable for mostapplications.

Both versions are supplied with door mounted strikerplates and can be fixed directly to a suitable wall,alternatively a floor bracket can be used to allow floormounting.

An override switch is fitted as standard to enabledoor to be manually released as required.

door strike plate

Features• Heavy duty construction• Mains and 24V dc version• Manual release switch• Optional floor mounting

bracket available

Benefits• Quick and simple to install• Slim profile unit

floor mounted heavy duty door retainer

wall mounted heavy duty door retainer

Page 46: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

46

Conventional Heavy Duty Door Retainers - MDR240 and MDR24L

Installation1. Door retainer unit and striker plate should be fixed

to a smooth surface.2. A single 20mm cable entry facility is provided.3. Door retainer can be rotated to provide cable entry

at either top, bottom or side as required.4. Fixings should be able to support at least double

the holding force of the magnet.

Code DescriptionMDR240 Conventional mains powered heavy duty magnetic door retainer MDR24L Conventional 24V dc heavy duty magnetic door retainer ZMDRFBB Floor mounting bracket for heavy duty door retainer

Product Codes

Code MDR240 MDR24L

Description Mains powered heavy duty door retainer 24V dc powered heavy duty door retainer

Specification

Operating Voltage 230V ac to 240V ac 24V dc

Power Consumption 1.2VA 40mA

Holding Force 40kg 40kg

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour White body / black plate White body / black plate

Dimensions (H x W x D) Magnet: 95mm x 95mm 40mm Magnet: 95mm x 95mm 40mm

Striker plate: 65mm x 65mm x 48mm Striker plate: 65mm x 65mm x 48mm

Weight 1.0kg 1.0kg

Ingress Protection IP40 IP40

Compatibility

Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Technical SpecificationDimensions

W

W

D

D

H

H

Description H (mm) W (mm) D (mm)Magnet 95 95 40Striker Plate 65 65 48

Standard Connection

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

INPUT VOLTAGE

TO HEAVY DUTY DOOR MAGNET

MDR240 / MDR24L

System Functionality1. Designed to operate only with

self closing doors.2. Door retainer is fitted to wall or

floor using floor bracket.3. Striker plate is fitted to door.4. Door retainer is fed with a

constant supply via an externalcontrol device.

5. Supply energises an electromagnet, which holds the striker plate securely against the magnet.

6. If supply to magnet is interrupted, magnet de-energises.

7. Door closes under control of its own self closing device.

Page 47: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

47

Intelligent Addressable Contents

Page 49Control PanelsDF6100

Page 55Control PanelsDF6000

Page 65Sensors MAP820, MAOH850 andMAH830

Page 67Standard Base MAB800

Page 69Sounder Base MAS850

Page 75Reflective Beam DetectorsMAB50R and MAB100R

Page 77Callpoints MBG813 and MBG817

Page 81Wall Sounder BeaconsMASB860 and MASB860WP

Page 71Sounder Beacon BaseMASB870

Page 79Wall Sounders MAS850LPS andMAS850LPSWP

Page 73Loop Connected Remote Indicator MRIAD

Page 85Interfaces

Page 83Loop Connected LED BeaconMAB870

Page 97Micro Interfaces

Page 61Passive Repeater PanelDF6000PR

Page 63Touch Screen Repeater PanelDTPR6000

Page 103Ancillaries and TestEquipment

Page 48: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable System Architecture

48

Intelligent Addressable Product Range

Standard conventional systems utilise simple twostate detectors, which simply provide a switch typesignal to the conventional control panel.

To enable the source of the alarm to be identified,each zone must be wired using a separate circuit,furthermore in the event of a fire alarm beingtriggered, the panel can only identify which zonecontains the triggered device, it is then necessary tomanually search the affected zone to discover theactual cause of the alarm.

Intelligent addressable systems overcome theselimitations, each fire detecting sensor or callpoint iselectronically coded with a unique identification or'address' which is programmed into the device duringinstallation.

The control panel is then able to conduct two waycommunication with any of the addressable devicesconnected to the system by using the unique addressnumber to define which device it wishes tocommunicate with. This operates in a similar mannerto that of a telephone number enablingcommunication between specific telephones.

Under normal conditions the control panelcontinuously interrogates each device in sequenceusing a low power digitally pulsedsignal, and analyses the reply to determine the statusof the sensor or callpoint.

In this manner, the panel can ascertain whether eachdevice is functioning correctly and also discover theamount of smoke or heat that the device is currentlysensing.

This technology allows the panel to make intelligentdecisions as to the appropriate action to take basedon the information it receives from the individualsensors.

This has many advantages, for example very slowbuild up of apparent smoke density seen by a sensorcan cause a warning or pre alarm condition to betriggered by the alarm panel prior to the situationbecoming serious enough to warrant a full alarm.

A typical practical benefit of this technology is thesituation whereby airborne dust particles enter smokedetectors and mimic the appearance of smoke, overtime the concentration of dust can increase to a pointwhere it can cause the detector to falsely trigger analarm condition. With an intelligent addressablesystem, a pre alarm condition will normally betriggered rather than a full alarm giving the buildingoperator the opportunity to clean or replace thesensor rather than suffer the disruption of anunwanted false alarm.

If whilst continually interrogating the smoke and heatsensors, the panel determines that the data gatheredfrom a specific device is appropriate to instigateeither a fire, fault or pre alarm condition, it uses theunique identifying number or address to determinewhich device is involved. Consequently the panel canpinpoint and identify precisely which device hastriggered the fire, fault or pre alarm condition.

This level of sophistication removes the need for eachzone of the building to be wired as a separate circuit.For this reason intelligent addressable systemcomponents are typically connected to the panelusing a small number of large loops thus greatlysimplifying the installation of the system and reducingthe installation cost.

Detectors instead of being simple two state devicesnow function as sensors continually communicatingwith the control panel and providing informationregarding the temperature or concentration ofsmoke in their local environment.

Zone 2

Zone 4

Zone 1

Zone 3

Mains Supply

1 2

3

4

5

6

78910

11

12

13

14

15 16

Page 49: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

49

DF6100 Control Panels

Overview

The Menvier DF6100 range is available as a highspecification 1 or 2 loop intelligent addressablecontrol panel, offering sophisticated functionalitywith simple end user operation.

The simplicity of operation, powerful cause and effectprogramming capability, and competitive pricingmake the system suitable for a wide range of small tomedium sized projects.

DF6100 uses soft addressing to minimise installationtime and remove the potential for error associatedwith manual addressing.

These panels can operate as a stand alone panel oras part of a network with the Menvier range ofDF6000 panels or other DF6100 panels, (additionalnetwork card required).

The DF6100 panel has an integral power supply andis supplied with batteries as standard.

An extensive range of compatible intelligentaddressable system ancillaries are available to workwith the DF6100 all of which incorporate an integralshort circuit isolator to provide maximum protectionagainst short circuits on the loop.

Features• Large versatile touch screen

display• Competitive single or two loop

system• Spur tolerant soft addressing• Large selection of compatible

ancillaries• Full network capability• Integral battery and power

supply• 200 address capacity per loop• Approved to EN54 Pt13

and EN54 Pt2 and Pt4

Benefits• Simple end user interface• Range of compatible ancillaries• System protocol allows fast

and accurate configuration

DF6100 control panel, interior DF6100 control panel

Page 50: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

50

Intelligent Addressable Control Panel - DF6100 and DF61002

Dimensions

WD

H

H (mm) W (mm) D (mm)375 375 95

Code DescriptionDF6100 Intelligent addressable 1 loop control panelDF61002 Intelligent addressable 2 loop control panelNC Add to end of product code if network card requiredDF61NETKIT Network kit (retro fit)DF6000PR Passive repeater panelDTPR6000 Touch screen repeater panelMFALOG Fire alarm system log book

Product Codes

Code DF6100 DF61002

Description 1 loop control panel 2 loop control panel

Standards EN54 Pt2 1997 & 2006: A1, EN54 Pt4 1997 & 2002: A1 EN54 Pt2 1997 & 2006: A1, EN54 Pt4 1997 & 2002: A1

EN54 Pt13, EN50130-4 EN54 Pt13, EN50130-4

Specification

Number of Loops 1 2

Addresses per Loop 200 200

Number of Conventional 2 monitored for open and short circuit 2 monitored for open and short circuit

Sounder Circuits (max 1.5A combined) (max 1.5A combined)

Auxiliary Fire Routing

Equipment Output (Monitored) 24V dc 30mA (max) 24V dc 30mA (max)

Auxiliary Fire Protection

Equipment Output (Monitored) 24V dc 30mA (max) 24V dc 30mA (max)

Auxiliary Fault Routing

Equipment Output (Monitored) 12V dc 30mA (max) 12V dc 30mA (max)

System Operating Voltage 24V dc (nom) 24V dc (nom)

Mains Input Supply 230V ac +10% / -15% 230V ac +10% / -15%

Class Change Facility Terminals for connection of external contacts, Terminals for connection of external contacts,

can also be instigated via input interface can also be instigated via input interface

Auxiliary Relay 1 set of changeover contacts 1 set of changeover contacts

operate in event of fire condition operate in event of fire condition

Output Ports RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc

Standby Duration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration

Battery 2 x 7Ah 2 x 7Ah

Environmental

Operating Temperature -5°C to +40°C -5°C to +40°C

Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH

Physical

Construction Steel back box Steel back box

Dimensions (H x W x D) 375mm x 375mm x 95mm 375mm x 375mm x 95mm

Weight 8kg 8kg

Ingress Protection IP30 IP30

Cable entries Top: cable knockouts (20mm) Back: cable aperture Top: cable knockouts (20mm) Back: cable aperture

System Networking Fully Networkable up to 127 panels Fully Networkable up to 127 panels

(requires additional network card, per panel) (requires additional network card, per panel)

Technical Specification

Page 51: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Control Panel - DF6100 and DF61002

51

Installation1. Panel is designed for surface or recessed mounting

(without the need for an additional bezel).2. Cable entry is by means of top entry knockouts in

the metal back box, along with a substantial rear entry cutout.

3. Panels are wall mounted via keyhole/slot mounting holes on back of housing.

4. Key operated hinged lockable door provides access to all internal wiring.

5. Cable entry can either be top or rear.6. Mains input protection is provided by integral fuse7. All external wiring should be in accordance with

relevant section of latest edition of BS5839-Pt1.8. Comprehensive installation and operation manual

provided with each system.

System Functionality1. Panel has 3 modes of operation, normal mode,

user maintenance mode and engineer mode.2. User maintenance and engineer modes can only

be accessed by entering relevant pass codes3. Maintenance mode allows access to system test

functions, enable and disable menus, view analogue level menus and functions such as evacuate, silence alarms and reset.

4. Engineer mode allows alteration of system configuration and programming of site specific data such as device text and sounder programming.

5. Engineer mode also allows adding and removal of devices and alteration of existing text.

6. DF6100 is designed to ensure simplicity of future expansion. If an additional device is added after the system has been programmed, the DF6100 willallocate the next available address, it will not alter any of the existing address number allocation thus enabling simple updating of ‘as fitted’ drawings etc. Similarly if a device is removed, the relevant address is saved as a spare address for future use,the addresses of the remaining devices are not affected.

7. All devices are soft addressed during commissioning however once allocated, addressesare locked until manually altered thus enabling simple system additions and deletions withoutaffecting other addresses.

8. In event of an external short circuit occurring, shortcircuit isolators on output of the devices nearest to each side of the short circuit open thus isolating the short circuit. The panel then drives communication from both ends of the loop thus maintaining full communication with all devices.

User Interface1. The main element of the user interface with

DF6100 is a large (120mm x 90mm visible area) touch screen display, which provides comprehensive user information and also acts as amultifunctional keypad. With other more basic systems, the user is limited to a small number of dedicated pushbuttons and consequently system interaction is restricted and complicated.

2. Comprehensive context sensitive help information is provided throughout the menus to assist unfamiliar users with system operation.

3. The DF6100 touch screen display automatically reconfigures to suit the selected function, for example, if the change device text menu option is selected, the touch screen is automaticallyformatted as a full QWERTY keyboard to enable fast and simple text entry.

4. As well as a large format LCD display providing full system status information, the panel incorporates 16 traditional zone indication LED's to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the system. In addition there are a number of system status LED's designed to give clear status information to non technical users

5. Audible buzzer with mute facility.6. Hinged lockable door provides access to all

internal wiring and components.

Detection Capacity1. Up to 200 addresses per loop which can be a

mixture of callpoints, detectors, interfaces or loop sounders.

2. DF6100 panels can be networked with all Cooper intelligent addressable and wireless panels.

Alarm Capacity1. Up to 80 loop powered outputs per loop

(60 sounders/beacons and 20 I/O units).2. 3 stages of cause and effect programming per

output device.3. 0.8A of panel connected conventional sounders.4. Additional conventional sounders can be

connected via loop mounted MPU424 units.

Interface Options• Day night mode override via

external switched signal. (Can be a timer).

• Multiple Programmable remoteinputs can be set:• Override of day night mode

setting- Photo-thermal detectors

go to thermal only.- Rate of rise detectors go

to fixed high temperature mode.

- High temperature heat detectors go to rate of rise mode.

• T1 and T2 timer.• HMO facility.• Comprehensive cause and

effect programming.• Test per zone or address.• Alarm verification per zone.• Coincidence detection.• Disablement of pre assigned

group of addresses.• Class change.• Non latching zone input.• Evacuate.• 2 Conventional sounder

circuits provided.• Zone monitor units can be

used to connect zones of suitable conventional detectorsor loop powered beam detectors.

• Sounder circuit controllers can be used to provide additional conventional sounder circuits without wiring back to main panel.

• Mains rated input/output unit available.

• 3 way 24V rated input/output unit available.

• Spur isolator available to allow spurs of intelligent addressabledevices.

• Compact input and output modules available

• Shop unit interface allows the connection of a conventional detection zone along with a power supply and 2 conventional sounder circuits, ideal for linking small self contained units onto a main addressable panel.

Page 52: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

52

Intelligent Addressable Control Panel - DF6100 and DF61002

System NetworkingDF6000 and DF6100 systems can both be networkedtogether. Up to 126 DF6000 panels, DF6100 panelsand low cost repeaters can be networked together tooperate as a single networked system.

To achieve this each panel must be fitted with anetwork card (optional extra). When operating as anetworked system all fire and fault event informationcan be displayed at every panel.

Panels can be configured by service engineers tocontrol whether fire and fault information from eachpanel is transmitted around the network or not.

Silencing and resetting of alarms can also be carriedout from any panel on a networked system.

Networked panels are connected using a looptopology as illustrated.

Mains Supply Mains SupplyMains Supply

Mains Supply Mains SupplyMains Supply

Mains Supply

2 circuits ofconventionalsounders

fire or non fire input

mains rated output relay contact

3 separate inputsto accept fire or non fire inputs

3 independentvolt free outputcontacts

4 independently controlledconventional sounder circuits

Mains Supply

spur of analogue devices

zone of compatible conventional devices

Mains Supply

input/output unit

3 way input/output unit

sounder controller unit

spur isolator unit zone monitor unit

shop monitor unit

control panel

zone of compatible conventional devices

2 circuits ofconventional

sounders

loop connectedrepeater panel

network connectedrepeater panel

Typical System Architecture

DF6100

DF6000, DF6100 and DTPR6000

Page 53: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Control Panel - DF6100 and DF61002

53

6K8 EOL RESISTOR*

}MENVIER CONVENTIONAL SOUNDERS(IF REQUIRIED)

6K8 EOL RESISTOR*

LOOP 1 CONNECTIONS

24V dc OUTPUT

NETWORK 2

NETWORK 1

FAULT RELAY

VOLT FREE CHANGE OVER CONTACT

VOLT FREE CHANGE OVER CONTACT

LOOP 2 CONNECTIONS (IF DF61002)

FIN

ISH

LO

OP

TE

RM

INA

LS

ST

AR

T L

OO

P T

ER

MIN

ALS

* required to be fitted to terminal if circuits not used

LO

OP

2

F-

F+

E

LO

OP

1+

24V

OU

TN

ET

WO

RK

2

F-

F+

E

S-

S+

ES

-S

+E

-+

EY

XB

A

NE

TW

OR

K 1

EY

XB

A

FA

ULT

RE

LA

YA

UX

RE

LA

Y 2

-+

NC

CN

O

AU

XR

ELA

Y 1N

CC

NO

SO

UN

DE

RC

IRC

UIT

1

+-

SO

UN

DE

RC

IRC

UIT

2

+-

6K8 EOL RESISTOR*6K8 EOL RESISTOR*

Standard Panel Connections

Page 54: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

54

Intelligent Addressable Product Range

Page 55: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

55

DF6000 Range Control Panels

Overview

The Menvier DF6000 is a high specificationintelligent addressable control panel available invarious loop configurations. It combinessophisticated functionality with simple operationand a very aesthetically pleasing design.

The large capacity, ability to support complex causeand effect programming and wide range of usercontrollable functions make the system suitable for adiverse range of projects from sheltered housing tolarge office developments and industrial applications.

DF6000 uses soft addressing to minimise installationtime and remove the potential for error associatedwith manual addressing.

The DF6000 can operate as a stand alone panel or aspart of a networked system. They have powerfulprogramming options that allow configurable controlover whether messages from specific panels aretransmitted around the network or remain local.

The DF6000 panel has integral power supply andbatteries the batteries are supplied with the panel asstandard.

An extensive range of compatible intelligentaddressable systems ancillaries are available to workwith the DF6000 all of which incorporate an integralshort circuit isolator to provide maximum protectionagainst short circuits on the external loop.

Features• 1, 2 and 4 loop versions• Spur tolerant soft addressing• Full network capability• Optional integral printer• Integral battery and power

supply• 200 addresses per loop• Charger with temperature

compensation built in• Checks battery capacity

Benefits• Simple end user interface• Range of compatible ancillaries• Easy to design system• System Integrity • Battery life can be extended

DF6000 control panel with printer DF6000 graphite control panel with protective cover and printer

rack mounted panels

Page 56: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

56

Intelligent Addressable Control Panels - DF6000 Range

Dimensions

D2

W

H

D1

Description H (mm) W (mm) D1 (mm) D2 (mm)Standard 395 495 55 125EB 395 495 55 225

Note: If surface mounting add D1 and D2 to obtain depth dimension.

Code DescriptionDF60001 1 loop control panelDF60002 2 loop control panelDF60004 4 loop control panelDF60001P 1 loop control panel, integral printerDF60002P 2 loop control panel, integral printerDF60004P 4 loop control panel, integral printerDF60001G 1 loop control panel, graphite finishDF60002G 2 loop control panel, graphite finishDF60004G 4 loop control panel, graphite finishDF60001PG 1 loop control panel, integral printer, graphite finishDF60002PG 2 loop control panel, integral printer, graphite finishDF60004PG 4 loop control panel, integral printer, graphite finishDF60002EB 2 loop control panel, extended batteryDF60004EB 4 loop control panel, extended batteryDF60002PEB 2 loop control panel, integral printer, extended batteryDF60004PEB 4 loop control panel, integral printer, extended batteryDF60002GEB 2 loop control panel, graphite finish, extended batteryDF60004GEB 4 loop control panel, graphite finish, extended batteryDF60002PGEB 2 loop control panel, graphite finish, integral printer, extended batteryDF60004PGEB 4 loop control panel, graphite finish, integral printer, extended batteryNC Add to end of product code if network card requiredDF6000NETKIT Network kit (for retor fit)DF6000COV Hinged protective cover kitDF6000PR Passive repeater panelDTPR6000 Touch screen repeater panel39UECRACK 19" rack, 39 units high*MFALOG Fire alarm system log book

Product Codes

Code DF60001 DF60002 DF60004

Description 1 loop control panel 2 loop control panel 4 loop control panel

Standards EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4

Specification

Number of Loops 1 2 4

Addresses per Loop 200 200 200

Number of Conventional

Sounder Circuits 4 monitored for open and short circuit 4 monitored for open and short circuit 4 monitored for open and short circuit

Auxiliary Fire Routing

Equipment Output (Monitored) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max)

Auxiliary Fire Protection

Equipment Output (Monitored) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max)

Auxiliary Fault Routing

Equipment Output (Monitored) 12V 30mA (max) 12V 30mA (max) 12V 30mA (max)

System Operating Voltage 24V dc (nom) 24V dc (nom) 24V dc (nom)

Mains Input Supply 230V ac +10% / -15% 230V ac +10% / -15% 230V ac +10% / -15%

Class Change Facility Terminals for connection of external contacts, Terminals for connection of external contacts, Terminals for connection of external contacts,

can also be instigated via input interface can also be instigated via input interface can also be instigated via input interface

Auxiliary Relay 1 set of changeover contacts operate in event of fire condition 1 set of changeover contacts operate in event of fire condition 1 set of changeover contacts operate in event of fire condition

Output Ports RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc

Standby Duration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration

Battery 2 x 12Ah (standard versions) 2 x 12Ah (standard versions) 4 x 12Ah (EB versions) 2 x 12Ah (standard versions) 4 x 12Ah (EB versions)

Environmental

Operating Temperature -5°C to +40°C -5°C to +40°C -5°C to +40°C

Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH

Physical

Construction Back box - mild steel, front door - PC/ABS Back box - mild steel, front door - PC/ABS Back box - mild steel, front door - PC/ABS

Dimensions (H x W x D) Standard versions: 395mm x 495mm x 180mm Standard versions: 395mm x 495mm x 180mm Standard versions: 395mm x 495mm x 180mm

EB versions: 395mm x 495mm x 280mm EB versions: 395mm x 495mm x 280mm

Weight 18kg 18kg 18kg

Ingress Protection IP30 IP30 IP30

Cable entries Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm)

System Networking Fully networkable up to 126 panels Fully networkable up to 126 panels Fully networkable up to 126 panels

(requires additional network card - 1 per panel) (requires additional network card - 1 per panel) (requires additional network card - 1 per panel)

Technical Specification

* For further information on the 39UERACK 19" rack and associated panels contact Cooper Fire technical support: 01302 303350

Page 57: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Control Panels - DF6000 Range

57

Installation1. Standard panel is designed for surface or recessed

mounting (without the need for an additional bezel).2. Cable entry is by means of top entry knockouts in

the metal back box, along with a substantial rear entry cutout.

3. Panels are wall mounted via keyhole/slot mounting holes on back of housing.

4. Front cover retained by screws, accessed after opening the printer bay door.

5. Flush mounting requires suitable aperture and fixings.

6. Mains input protection is provided by a polyswitch.7. All external wiring should be in accordance with

relevant section of latest edition of BS5839-Pt1.8. Comprehensive installation and operation manual

provided with each system.9. Maximum length of network cable loop is 1500

metres, beyond this distance or where cables passbetween buildings, boosters will be required.

System Functionality1. Panel has 3 modes of operation, normal mode,

user maintenance mode and engineer mode.2. User maintenance and engineer modes can only

be accessed by entering relevant pass codes3. Maintenance mode allows access to system test

functions, enable and disable menus, view analogue level menus and functions such as evacuate, silence alarms and reset.

4. Engineer mode allows alteration of system configuration and programming of site specific data such as device text and sounder programming.

5. Engineer mode also allows adding and removal of devices and alteration of existing text.

6. DF6000 is designed to ensure simplicity of future expansion. If an additional device is added after the system has been programmed, the DF6000 willallocate the next available address, it will not alter any of the existing address number allocation thus enabling simple updating of ‘as fitted’ drawings etc. Similarly if a device is removed, the relevant address is saved as a spare address for future use,the addresses of the remaining devices are not affected.

7. All devices are soft addressed during commissioning however once allocated, addressesare locked until manually altered thus enabling simple system additions and deletions withoutaffecting other addresses.

8. In event of an external short circuit occurring, shortcircuit isolators on output of devices nearest to each side of the short circuit open thus isolating the short circuit. The panel then drives communication from both ends of the loop thus maintaining full communication with all devices.

User Interface1. The main element of the user interface with

DF6000 is a large (120mm x 90mm visible area) touch screen display, which provides comprehensive user information and also acts as amultifunctional keypad. With other more basic systems, the user is limited to a small number of dedicated pushbuttons and consequently system interaction is restricted and complicated.

2. Comprehensive context sensitive help information is provided throughout the menus to assist unfamiliar users with system operation.

3. The DF6000 touch screen display automatically reconfigures to suit the selected function, for example, if the change device text menu option is selected, the touch screen is automaticallyformatted as a full QWERTY keyboard to enable fast and simple text entry.

4. As well as a large format LCD display providing full system status information, the panel incorporates 96 traditional zone indication LED's to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the system. In addition there are a number of system status LED's designed to give clear status information to non technical users

5. Access to printer (when fitted) is via separate locked access door. Paper can be changed by nonskilled personnel without exposure to any live components.

6. The printer can either be set to print on demand or to automatically print all system events as they occur.

7. The hinged front door provides simple access to allinternal components and wiring.

8. The panel door cannot be opened without the use of a special key (supplied with panel).

9. For applications requiring a high level of resilience, a clear hinged lockable front cover is available that still allows full system visibility but prevents unauthorized access to the touch screen.

Interface Options• Monitored output to fire routing

equipment.• Monitored output to fire

protection equipment.• Monitored output to fault

monitoring equipment.• Multiple Programmable remote

inputs can be set:• Override of day night mode

setting- Photo-thermal detectors

go to thermal only.- Rate of rise detectors go

to fixed high temperature mode.

- High temperature heat detectors go to rate of rise mode.

• Disablement of pre assigned group of addresses.

• Class change.• Non latching zone input.• Evacuate.• 4 Conventional sounder

circuits provided.• Zone monitor units can be

used to connect zones of suitable conventional detectors and callpoints.

• Sounder circuit controllers can be used to provide additional conventional sounder circuits without wiring back to main panel.

• Mains rated input/output unit available.

• 3 way 24V rated input/output unit available.

• Spur isolator available to allow spurs of intelligent addressabledevices.

• Compact input and output modules available

• Shop unit interface allows the connection of a conventional detection zone along with a power supply and 2 conventional sounder circuits, ideal for linking small self contained units onto a main addressable panel.

Detection Capacity1. Up to 200 addresses per loop which can be a

mixture of callpoints, detectors, interfaces loop sounders or repeaters.

2. To comply with EN54 requirements no more than 512 addresses should be connected to a single panel.

3. Panels are available with up to 4 detection loops, up to 126 panels can be networked together givinga total system capacity of over 32,000 devices.

Alarm Capacity1. Up to 80 loop powered outputs per loop

(60 sounders/beacons and 20 I/O units).2. 3 stages of cause and effect programming per

output device.3. Depending on loop load up to 3A of panel

connected conventional sounders.4. Additional conventional sounders can be

connected via loop connected MPU424 units.

Page 58: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

58

Intelligent Addressable Control Panels - DF6000 Range

System NetworkingDF6000 and DF6100 systems can both be networkedtogether. Up to 126 DF6000 panels, DF6100 panelsand low cost repeaters can be networked together tooperate as a single networked system.

To achieve this each panel must be fitted with anetwork card (optional extra). When operating as anetworked system all fire and fault event informationcan be displayed at every panel.

Panels can be configured by service engineers tocontrol whether fire and fault information from eachpanel is transmitted around the network or not.

Silencing and resetting of alarms can also be carriedout from any panel on a networked system.

Networked panels are connected using a looptopology as illustrated.

Mains Supply Mains SupplyMains Supply

Mains Supply Mains SupplyMains Supply

Networking DF6000

DF6000, DF6100 and DTPR6000

Mains Supply

2 circuits ofconventionalsounders

fire or non fire input

mains rated output relay contact

3 separate inputsto accept fire or non fire inputs

3 independentvolt free outputcontacts

loops 2-4 if fitted

4 independently controlledconventional sounder circuits

Mains Supply

spur of analogue devices

zone of compatible conventional devices

Mains Supply

input/output unit

3 way input/output unit

sounder controller unit

spur isolator unit zone monitor unit

shop monitor unit

control panel

zone of compatible conventional devices

2 circuits ofconventional

sounders

network connectedrepeater panel

loop connectedrepeater panel

Typical System Architecture

Page 59: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Control Panels - DF6000 Range

59

CLASS CHANGE INPUT IF REQUIRED

VOLT FREE CHANGE OVER CONTACT

6K8 EOL RESISTOR*

START LOOP 1

}

6K8 EOL RESISTOR*

6K8 EOL RESISTOR*

FINISH LOOP 1

START LOOP 2

FINISH LOOP 2

START LOOP 3

FINISH LOOP 3

START LOOP 4

FINISH LOOP 4

6K8 EOL RESISTOR*}

MENVIER CONVENTIONAL SOUNDERS(IF REQUIRED)

6K8 EOL RESISTOR*

* required to be fitted to terminal if circuits not used

+5.5V SUPPLY FOR PRINTER (IF FITTED)

AU

XR

ELA

YF

AU

LT

RE

LA

Y+

24V

O/P

FIR

ER

/E

FIR

EP

/ELO

OP

1LO

OP

2LO

OP

3LO

OP

4

LO

OP

CIR

CU

ITS

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1

SO

UN

DE

RC

IRC

UIT

2M

OD

EM

/PC

Rs2

32

MIM

CR

EP

EA

TE

R

NO

CN

C-

+-

+-

-+

S+

S-

F-

F+

S+

S-

F-

F+

S+

S-

F-

F+

S+

S-

F-

F+

-+

1-

++

2-

1-

++

2-

Rx

Tx

CT

SR

TS

0V

Tx+

Tx-

+

Standard Panel Connections

Page 60: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

60

Intelligent Addressable Product Range

Page 61: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

61

Passive Repeater Panel DF6000PR

Overview

The DF6000PR is a cost effective passive repeaterpanel which can be programmed via its informativedisplay to be either fully passive (display only) orsemi passive (restricted system control).

When loop connected the repeater panel will displaythe system information text of the connected controlpanel and will provide a fire indication, with panelnumber, of any connected network control panel thathas fire activation.

The DF6000PR repeater panel only requiresprogramming with local text information.

In addition to the repeater panels main menu driven 2 x 40 backlit LCD display, which provides systemstatus information, it also has 6 supervisory LED’s(Power On, Alarm, Trouble, Supervisory, Test InProgress, and Scroll).

2 x 40 backlit LCD display and 6 supervisory LED’s

Features• Up to 20 repeaters can be

connected to the loop• 2 x 40 backlit LCD display and

6 supervisory LED’s• Compact size• Can be surface or semi-

recessed mounted

Benefits• Menu driven easy to operate• Simple connection to panel

loop circuit reduces wiring and installation time

• Distance run up to 2km frommain panel without additionalcable and equipment, saving cost

simple user interface DF6000PR passive repeater panel

Page 62: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

62

Intelligent Addressable Passive Repeater Panel - DF6000PR

Code CF30000PR

Description Passive repeater panel

Standards EN54 Pt4

Specification

Mains Input Voltage 230V ac +10% / -15%

Operating Voltage 24V dc

System Indicators Power on, fire, fault, test, disable and scroll

System Controls Silence alarms, evacuate and reset

Input Ports RS232 (for connection of programmer)

Battery 1 x 12V 3.2Ah

Standby Duration 24 hours

Environmental

Operating Temperature 0°C to +25°C

Humidity (Non Condensing) 0 to 75% RH

Physical

Construction PC/ABS

Colour Light Grey

Dimensions (H x W x D) 332mm x 270mm x 92mm

Weight 3.6kg

Ingress Protection IP30

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Technical Specification

Installation1. Wall mounted by means of 4 fixing screws.2. Cable entry at top or back.3. 12 top entry gland holes with push out blanking

plugs.4. 4 separate rear access cable entry facilities.5. Local mains supply required.

System Functionality1. Panel operates in either normal, supervisor or

engineer mode.2. Supervisor and engineer modes are accessed via

4 digit pass codes.3. Supervisor mode allows silence, evacuate and

reset commands to be sent to host panel (loop connected) or to network (network connected).

4. Engineer mode enables password to be changed ifrequired and allows access to text download menu

5. When connected to network, all text is transmitted via network, changes to other network panels update automatically.

6. When connected to a detector loop, text for host isdownloaded to repeater and updated manually as required.

7. Zonal fire and fault indication isby means of 2 x 40 character LCD display.

Device Overview1. Panel can be connected to

either the detection loop of a single panel or to a network as part of a networked system.

2. Supplied with integral power supply and standby battery.

Dimensions

W

H

D2

D1

1 2 3 4 5

SCROLLMUTEBUZZER

H (mm) W (mm) D1 (mm) D2 (mm)270 332 45 47

Code DescriptionDF6000PR Intelligent addressable passive repeater panel, loop connectedDF6000PRNC Intelligent addressable passive repeater panel, network connected

Product Codes

Mains Supply

Network Link

Mains Supply

Mains Supply

Network Link

Loop Connected

Network Connected

Note: In this configuration the repeater would give ‘text’ information for the panel that is on the loop, but only address number for the other panel on the network.

Standard Connection

- +SC

RE

EN

- +SC

RE

EN

LOOPOUT

LOOPIN

SC

RE

EN

Tx

+

Tx

-

Rs485MIMIC

TEXT DOWNLOAD

Page 63: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

63

Touch Screen Repeater Panel DTPR6000

Overview

The DTPR6000 touch screen repeater panelprovides sophisticated ‘touch screen’ functionalityyet achieves a simple end-user interface operationwithin a compact panel design.

The DTPR6000 is designed to work with all Menvierintelligent addressable fire alarm control panels aswell as other network repeaters.

The Menvier touch-screen repeater panel is easy toinstall and commission. All text is transmitted via thenetwork and is automatically updated.

Features• Plug and play. All information is

downloaded through the network

• Touch-screen display• Integrated network capability

allows networking with the latest Menvier range of intelligent addressable fire alarm control panels

• Multi language capability• Up to 126 repeaters can be

connected to the network• Programmable as an active or

passive repeater

Benefits• Plug and play requires no

programming• User friendly touch screen

display• System integrity, fire alarm

system continues to operateeven if there is a short circuit oropen joint on cable

• Multi language capability

DTPR6000 touch screen repeater panel

Page 64: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

64

Touch Screen Repeater Panel - DTPR6000

Installation• Wall mounted by means of 4 fixing screws.• Cable entry at top or back.• 11 top entry gland holes. • Separate rear access cable entry facility.• Local mains supply required.• Must be network connected.

System Functionality• Panel operates in either normal, supervisor or

engineer mode.• Supervisor and engineer modes are accessed via

4 digit pass codes.• Supervisor mode allows full system operation.• Engineer mode enables password to be changed if

required and allows access to text download menu• When connected to network, all text is transmitted

via network, changes to other network panels update automatically.

Device Overview• Panel is connected to the

network as part of a networkedsystem.

• Supplied with integral power supply and standby battery.

• Touch screen user interface.

DimensionsWD

H

H (mm) W (mm) D1 (mm)375 537 50

Code DescriptionDTPR6000 Intelligent addressable touch screen repeater panel

Product Codes

Mains Supply

Network Link

Network Connected

Code DTPR6000

Description Touch screen repeater panel

Standards EN54 Pt4

Specification

Mains Input Voltage 230V ac +10% / -15%

Operating Voltage 24V dc

System Indicators Power on, fire, fault, test, disable and scroll

System Controls Silence alarms, evacuate and reset

Input Ports RS232 (for connection of programmer)

Battery 2 x 12V 3.2Ah

Standby Duration 24 hours

Environmental

Operating Temperature -5°C to +40°C

Humidity (Non Condensing) 0 to 75% RH

Physical

Construction PC/ABS

Colour Graphite

Dimensions (H x W x D) 375mm x 357mm x 50mm

Weight 8kg

Ingress Protection IP30

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Technical Specification

Standard Connection

+24V dcIN

-+

+24V dcOUT

-+

NETWORK 1

A B X Y E

NETWORK 2

A B X Y E

FAULTRELAY

NO NCC

AUXRELAY

NO NCC

PROGRAMMABLEINPUT

E

TO PANEL EARTH

Page 65: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

65

Sensors MAP820, MAOH850 and MAH830

Overview

The Menvier range of intelligent addressablesensors have been specifically designed to operatewith Menvier intelligent addressable control panels.

All sensors are third party approved to the relevantsection of EN54 (part 7 for smoke detectors & part 5for heat detectors).

Features• Soft addressed• Integral short circuit isolator• Wide range of sensor types• 360° visibility LED

Benefits• Single ‘multi-mode’ heat

sensor

MAP820 optical sensor

MAOH850 photo-thermal sensor

MAH830 heat sensor

optical / photo-thermal / heat detectors

Page 66: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Code MAP820 MAOH850 MAH830

Description Optical smoke sensor Photo-thermal sensor Multi-mode heat sensor

Standards EN54 Pt7 2000 + A1:2002 EN54 P5 & P7 2000 + A1:2002 EN54 Pt5 2000 + A1:2002

Operating voltage 18V dc to 30V dc 18V dc to 30V dc 18V dc to 30V dc

Standby Current 220µA (max) 220µA (max) 220µA (max)

Alarm Current 5mA (max) 5mA (max) 5mA (max)

Addressing Mode Auto address Auto address Auto address

Specification

Mounting Position Ceiling in open areas Ceiling in open areas Ceiling in open areas

Mounting Options Surface mount with MAB800 base Surface mount with MAB800 base Surface mount with MAB800 base

Area Coverage 100m² (subject to local standard) 100m² (subject to local standard) 50m² (subject to local standard)

System Wiring Min. 1.5mm, 2 core loop or spur Min. 1.5mm, 2 core loop or spur Min. 1.5mm, 2 core loop or spur

Heat Class

Rate of Rise N/A A1S A1R

Fixed Heat 77ºC N/A N/A BS

Fixed Heat 90ºC N/A N/A CS

Alarm Temperature (static)

AIR N/A 60ºC 60ºC

BS N/A N/A 77ºC

CS N/A N/A 90ºC

Indication 360° visibility light pipe 360° visibility light pipe 360° visibility light pipe

Environmental

Operating Temperature -20°C to +60°C -20°C to +50°C -20°C to +60°C

Humidity (non condensing) 0 to 95% RH 0 to 95% RH 0 to 95% RH

Physical

Construction PC/ABS PC/ABS PC/ABS

Colour White White White

Dimensions Excl Base (Dia x D) 101mm x 33mm 101mm x 43mm 101mm x 43mm

Dimensions Incl Base (Dia x D) 104mm x 45mm 104mm x 55mm 104mm x 55mm

Weight (without base) 76g 76g 76g

Compatibility

Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

66

Intelligent Addressable Sensors - MAP820, MAOH850 and MAH830

Installation1. Sensors are fixed and wired via common

mounting base.2. Cable entry into base can be rear or side.3. A locking facility is provided which can be

activated if required to prevent unauthorised sensor removal without the use of a special tool.

Technical Specification

Dimensions

Dia

D

Code DescriptionMAP820 Intelligent addressable optical smoke sensorMAOH850 Intelligent addressable photo/thermal sensorMAH830 Intelligent addressable multi-mode heat sensorMAB800 Intelligent addressable common baseMAB800*10 Intelligent addressable common base (pack of 10)MDP201 Duct Probe

Product Codes

Description Dia (mm) D (mm) D (mm)(excl base) (incl base)

Optical 101 33 45Photo-thermal 101 43 55Multi-mode heat 101 43 55

User Interface1. LED indicates detector status,

can be set to flash to confirm communication with control panel, illuminates continuously under fire conditions.

2. All wiring connections are via acommon mounting base (ordered separately).Note: For wiring information please see

MAB800 base

Page 67: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

67

Standard Base MAB800

Overview

The MAB800 Menvier intelligent addressablestandard base has been specifically designed to becompatible with Menvier intelligent addressablesensors.

This standard base has been designed for flexibility,simplicity and speed of installation. It incorporates apurpose designed shorting link to ensure wiringcontinuity if a sensor is removed.

The standard base incorporates a retaining clip toprovide positive feedback when sensor is correctlyfitted and a retaining clip that can be replaced withlocking device (supplied with base) to preventunauthorised sensor removal.

Features• Sensor shorting link• Separate loop in and loop out

terminals• Stand off fixing feature• Accepts side entry cables• Selectable sensor locking

feature

Benefits• Quick and simple to install• Accepts side entry surface

cables• Common base for Menvier

intelligent addressable sensors

MAB800 standard base

MAP820 optical sensor

MAOH850 photo-thermal sensor

MAH830 multi-mode heat sensor

Suitable sensors for use with theMAB800 standard base

Page 68: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

68

Intelligent Addressable Standard Base - MAB800

Installation1. Separate terminals are provided for loop in and

loop out connections.2. Each terminal can accept up to 2 x 2.5mm cables.3. Base incorporates a substantial cable entry

aperture in the rear of the base.4. Breakouts are provided to enable the sensor

base to sit neatly over surface cables and then enter via the rear entry aperture.

5. Base mounting incorporates a stand off feature to help prevent distortion when mounted on an uneven surface.

6. Fixings are suitable for standard BESA box or direct fixing to suitable surface.

Dimensions

D

Dia

Dia (mm) D (mm)104 22

Code DescriptionMAB800 Intelligent addressable standard base

Product Codes

Standard Connection

2

4

1

3

ELE

D

WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact

Ensure that cable or end of line resistor leg does not short onto the contact.

2

4

1

3

E

LED

+ V

- VE IN

- VE OUT

Com

pat

ible

Men

vier

In

telli

gent

Ad

dre

ssab

le

Con

trol

Pan

el

Lo

op

finis

hLo

op

sta

rt S+

S-

F+

F-

remote indicator (optional)+

earth screen of cable must be continuous

Code MAB800

Description Standard base

Physical

Construction PC/ABS

Colour White

Dimensions (Dia x D) 104mm x 22mm

Compatibility

Suitable for use with Menvier intelligent addressable sensors

Technical Specification

User Interface1. Heavy duty terminals are

provided for each connection, each terminal can accept 2 x 2.5mm cables.

2. Separate loop in and loop out terminals are provided for eachconnection.

Page 69: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

69

Sounder Base MAS850

Overview

The intelligent addressable Menvier sounder basehas been developed specifically to operate with thelatest generation of Menvier intelligent addressablepanels and to complement the latest generation ofMenvier intelligent addressable sensors.

The MAS850 sounder base incorporates a sensormounting base, a sensor can be fitted to the sounderbase or alternatively an optional cover plate can beused to enable the sounder to operate as a dedicateddiscreet stand alone sounder.

Features• Integral sensor mounting base• Can be used with a sensor as

a sounder base or stand alone sounder

• Optional cover plate available

Benefits• First fix base• Selectable tones controlled by

the panel• Adjustable volume controlled

by the panel

MAS850 incorporates standard detector base

MAS850 with cover fitted

MAS850 sounder base

Page 70: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

70

Intelligent Addressable Sounder Base - MAS850

Installation1. Installation is simple using first fix base.2. First fix base is fixed to mounting surface via

2 fixings holes.3. Cables enter through aperture in base (rear entry

only)4. Main body is then clipped into place on base, main

body locks into place when pressed into position.5. Cables pass through aperture in sounder body and

terminate at the front.6. Connections are to connector block on front of

main sounder body.

Dimensions

D

Dia

Dia (mm) D (mm)102 40

Code DescriptionMAS850 Intelligent addressable sounder baseMASC Sounder cover plates (pack of 5)

Product Codes

Standard Connection

2

4

1

3

E

LED

+ - + -

2

4

1

3

E

LED

+ - + -

Com

pat

ible

Men

vier

In

telli

gent

Ad

dre

ssab

le

Con

trol

Pan

e l

Lo

op

finis

hLo

op

sta

rt

S+

S-

F+

F-

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Earth screen must be continuous along entire length of loop.

NOTE:Base terminal 1, 2, 3 and 4 not used. All wiring terminates as shown above.

Code MAS850

Description Sounder base

Standards EN54 Pt3

Specification

Operating Voltage 17V dc to 32V dc

Standby Current < 320μA

Tones (set by panel) Continuous: 910Hz

Pulsed: 910Hz / 0Hz pulse 1Hz

Two tone: 610 / 910Hz @ 1Hz cycle

Slow whoop

Sound Output @ +/-3dB Low volume : 84dB at <4mA

(set by panel) Medium volume : 92dB at <8mA

High volume : 95dB @ <12mA

Environmental

Operating Temperature -10 to +55°C

Humidity (Non Condensing) 0 to 95% RH

Physical

Construction PC/ABS

Colour White

Dimensions (Dia x D) 120mm x 40mm

Weight 0.2kg

Ingress Protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Technical Specification

7. Sensor or cover plate is then fixed to sounder.

8. Sensor or cover plate can be locked in place if required.

System Functionality1. Volume and tone are set by

control panel, no need to access sounder to alter setting.

2. Soft addressed.

Page 71: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

71

Sounder Beacon Base MASB870

Overview

The intelligent addressable Menvier sounderbeacon base has been developed specifically tooperate with the latest generation of Menvierintelligent addressable panels and Menvier sensors.

The MASB870 sounder beacon base includes all thefeatures of the intelligent addressable sounder baseas well as a powerful LED beacon.

The intelligent addressable beacon base incorporatesa detector mounting base, a sensor can be fitteddirectly to the base, or alternatively an optional coverplate can be used to provide a dedicated discreetstand alone device.

Features• Integral sounder base• Integral high output LED

beacon• Integral sensor mounting base• Can be used with a sensor or

stand alone• Selectable tones controlled by

the panel• Adjustable volume controlled

by the panel• Optional cover plate available

Benefits• Saves time and installation

costs• Single point connection for

sensor, sounder and LED strobe

MASB870 sounder beacon base

MASB870 with sensor fitted

Page 72: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

72

Intelligent Addressable Sounder Beacon Base - MASB870

Installation1. Installation is simple using first fix base.2. First fix base is fixed to mounting surface via

2 fixings holes.3. Cables enter through aperture in base (rear entry

only)4. Main body is then clipped into place on base, main

body locks into place when pressed into position.5. Connections are to connector block on front of

main sounder body.6. Sensor or cover plate is then fixed to sounder, (can

be locked in place if required).

Dimensions

Dia

D

Dia (mm) D (mm)115 44

Code DescriptionMASB870 Intelligent addressable sounder beacon baseMASC Sounder beacon cover plates (pack of 5)

Product Codes

Code MASB870

Description Sounder beacon base

Standards EN54 Pt3

Specification

Operating Voltage 17V dc to 32V dc

Standby Current < 320μA

Tones (set by panel) Continuous: 910Hz

Pulsed: 910Hz / 0Hz pulse 1Hz

Two tone: 610 / 910Hz @ 1Hz cycle

Slow whoop: 500 – 1200Hz in 3.5 Seconds

Sound Output at +/-3dB Low volume : 77dB at <6.6mA

(set by panel) Medium volume : 89dB at <8mA

High volume : 90dB @ <9mA

Environmental

Operating Temperature -10 to +55°C

Humidity (Non Condensing) 0 to 95% RH

Physical

Construction PC/ABS

Colour White

Dimensions (Dia x D) 115mm x 44mm

Weight 0.2kg

Ingress Protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Technical Specification

System Functionality1. Volume and tone are set by

control panel, no need to access sounder to alter setting.

2. Soft addressed.

Standard Connection

2

4

1

3

E

LED

+ - + -

2

4

1

3

E

LED

+ - + -

Com

pat

ible

Men

vier

In

telli

gent

Ad

dre

ssab

le

Con

trol

Pan

el

Lo

op

finis

hLo

op

sta

rt

S+

S-

F+

F-

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Earth screen must be continuous along entire length of loop.

NOTE:Base terminal 1, 2, 3 and 4 not used. All wiring terminates as shown above.

Page 73: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

73

Loop Connected Remote Indicator MRIAD

Overview

The MRIAD intelligent addressable loop connectedremote indicator is designed to provide discreetremote indication, which is controlled by theintelligent addressable fire panel, whilst providingthe ability to monitor multiple detectors within anarea thereby minimising wiring requirements.

The unit is connected directly on the loop, is ‘softaddressed’ by the panel on system start up and isfitted with integral short circuit isolators.

When using “Site installer” the MRIAD should beprogrammed as an address output (sounder) andcan be programmed using the comprehensive causeand effect tables to operate continuous, pulsing, byglobal, panel, zone, address or on double knock inputetc.

The unit is supplied complete with back box and issurface mounted.

Features• Simple to install• Fits onto standard single gang

back box• Wide viewing angle high

brightness LED• Attractive styling

Benefits• Can be remote mounted• Controlled by the panel• Can be activated by cause and

effect• Reduced cost• Minimises cabling

MRIAD loop connected remote indicator

Page 74: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

74

Intelligent Addressable Remote Indicator - MRIAD

Code MRIAD

Description Loop connected remote indicator

Specification

Operating Voltage 24V dc

Quiescent Current 220μA

Alarm Current 6mA

Cable Size 0.5 mm² to 2.5 mm²

Environmental

Operating Temperature -10°C to +55°C

Humidity (Non Condensing) 0 to 95% RH

Physical

Construction ABS

Colour White

Lens Colour Red

Dimensions (H x W x D) 87mm x 87mm x 49mm

Weight 0.28kg

Ingress Protection IP30

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Technical Specification

Installation1. Mounting plate fixes to single gang back box or

can be direct fixed to wall or ceiling.2. Cable entry is normally from rear but breakouts are

provided in side of base plate3. Cables connect to terminals on PCB within base

plate.4. Front cover is pushed onto base plate and locks in

place.

DimensionsD

H

W

H (mm) W (mm) D (mm)87 87 49

System Functionality1. MRIAD is addressable and is

programmed to activate when selected detectors are triggered.

2. LED cancels when detector is reset.

3. Low current consumption.

Code DescriptionMRIAD Intelligent addressable loop connected remote indicator

Product Codes

Terminal block unplugs for ease of connection

Standard Connection

LOO

PIN

LOO

PO

UTCompatible Menvier

Intelligent Addressable Control Panel

- + - +

IN OU

T

screen connected using suitable terminal in backbox

MRIAD

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of loop.

Page 75: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

75

Reflective Beam Detectors MAB50R and MAB100R

Overview

The Menvier loop powered reflective beamdetectors are specifically designed to function withthe latest intelligent addressable Menvier controlpanels.

Two versions are available, the MAB50R with a rangeof up to 50 metres, and the MAB100R with a range of50 - 100 metres.

Both of these units are extremely simple to install,they require no separate power supply, operate on areflective principle and have a simple set up mode toenable easy and quick alignment during installation.

Beam detectors are designed to replace individualpoint detectors in large open areas such aswarehouses.

Fire and fault conditions are signalled to panel usingstandard loop wiring so no additional interconnectionrequired.

combined transmitter and receiver for ease ofinstallation

optional mounting bracket with cable clamp facilities

Features• Quick and simple to install• IP40 protection• Simple loop connection• No power supply required

Benefits• Saves time and installation

costs• Single device to install instead

of numerous point detectors• Single point of maintenance• Wall mounted for ease of

maintenance, especially inwarehouses with racking

MAB50R and MAB100R reflective beam detectors

Page 76: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

76

Intelligent Addressable Reflective Beam Detectors - MAB50R and MAB100R

Installation1. Must be fixed to solid structure.2. Recommended mounting height is 0.3 to 0.6

metres below the ceiling.3. Cables can be terminated into separate termination

box (not supplied) or use purpose designed mounting bracket (MRBFP) ordered separately.

4. Mounting bracket has facilities for glanding of incoming cables plus simple fixing of beam detector.

5. Test filter is supplied with detector to simulate required smoke obscuration level and confirm correct operation.

Dimensions

H D

W

H (mm) W (mm) D (mm)210 130 120

Code DescriptionMAB50R Intelligent addressable reflective beam detector 50m rangeMAB100R Intelligent addressable reflective beam detector 100m rangeMRBFP Mounting bracket

Product Codes

System Functionality1. Beam detectors have 3 modes

• Prism targeting modedesigned to provide simple initial alignment of beam andreflector assembly.

• Alignment mode Enables accurate fine tuningof beam alignment without the need for additional calibration equipment or a second operator.

• Normal running mode

User Interface1. Beam detectors status LEDs

• Red LED constantly illuminated indicates fire condition

• Flashing amber LED indicates fault condition

Code MAB50R MAB100R

Description Reflective beam detector Reflective beam detector

Standards EN54 Pt 12 & 17 2002 EN54 Pt 12 & 17 2002

Specification

Operating Voltage 18V dc to 30V dc 18V dc to 30V dc

Quiescent Current <5mA (no LED’s illuminated) <5mA (no LED’s illuminated)

Alarm Current <9mA <9mA

Alignment Current <18mA <18mA

Power up Time 10 seconds (approx) 10 seconds (approx)

Operating Range 5 to 50 metres 50 to 100 metres

Tolerance to Beam

Misalignment at 35% Detector ± 0.8°, Prism ± 5.0° Detector ± 0.8°, Prism ± 5.0°

Fire Alarm Thresholds 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 2.50dB (25%) 3.74dB (35%) 6.02dB (50%)

Optical Wavelength 880nm 880nm

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour White White

Dimensions (H x W x D) 210mm 130mm x 120mm 210mm 130mm x 120mm

Weight 0.8kg 0.8kg

Ingress Protection IP40 IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Technical Specification

Standard Connection

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of loop.

LOO

PIN

LOO

PO

UTCompatible Menvier

Intelligent Addressable Control Panel

+ -

IN OU

T

screen connected using suitable terminal in backbox

to beam detector socket

+ -

MAB50R / MAB100R

Page 77: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

77

Callpoints MBG813 and MBG817

Overview

This attractively designed simple to install range ofcallpoints have been specifically developed to becompatible with Menvier intelligent addressable firesystems.

There are two versions of callpoint in this range. TheMBG813 which can be either surface or flushmounted and the MBG817 weatherproof version.

All callpoints are supplied as standard with afrangible glass element and a test key for ease ofmaintenance.

A comprehensive range of accessories are availableto maximise the functionality of the callpoint forparticular applications.

Features• Fast fit clip on front cover• High visibility status LED • Standard and weatherproof

versions available• Wide range of available

accessories• Heavy duty terminals

Benefits• Quick and simple to install• Fast fit clip on front cover• Single tool for test and access

MBG817 weatherproof callpoint

MBG813 callpoint

MBGBEZ recessing bezel

MBGHCC protective hinged cover

Page 78: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

78

Intelligent Addressable Callpoints - MBG813 and MBG817

Installation1. Surface callpoint has standard rear BESA fixing

facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted.

2. Callpoint has test facility via special test key to prevent unauthorised operation.

3. Insertion of test key for test purposes and for coverremoval is at bottom of callpoint to facilitate ease of access when mounted next to door architrave.

4. Test key is dual function, used to test callpoint operation by simulating activation and also to allowremoval of clip on cover to gain access to element.

5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key).

6. Separate loop in and loop out terminals are provided for all connections including screen continuity on intelligent addressable callpoints.

7. Surface/flush callpoints are IP42, weatherproof is IP65.

User Interface1. To enable quick and simple installation, callpoints

use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied).

2. Callpoint is triggered by pressing against the element.

Code DescriptionMBG813 Intelligent addressable surface/flush callpointMBG817 Intelligent addressable weatherproof callpointMBGHCC Protective hinged coverMBGSP Spacer plates (pack of 10)MBGBEZ Recessing bezels (pack of 10)MBGREKIT Resettable element kit (pack of 10)MBG118 Spare break glasses (pack of 5)MBG119 Earth continuity links (pack of 5)MFBGKEY3 Callpoint keys (pack of 10)

Product Codes

Accessories• Semi recess bezel• Spacer plates• Hinged clear cover• Resettable plastic element• Replacement test key• Replacement glass elements• Earth continuity links

Code MBG813 MBG817

Description Surface / flush mounting callpoint Weatherproof callpoint

Standards EN54 Pt11 EN54 Pt11

Specification

Operating Voltage 17V dc to 32V dc 17V dc to 32V dc

Quiescent Current < 250μA < 250μA

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Dimensions (H x W x D) 87mm x 87mm x 57mm (36mm flush) 87mm x 87mm x 59mm

Weight 0.2kg 0.2kg

Ingress Protection IP42 IP65

Compatibility

Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Technical SpecificationDimensions

D

H

W

Description H (mm) W (mm) D (mm)Flush mounted 87 87 36Surface mounted 87 87 57Weatherproof 87 87 59

Standard Connection

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of loop.

LOO

PIN

LOO

PO

UTCompatible Menvier

Intelligent Addressable Control Panel

- + - +E E

Scr

een

IN OU

T

Scr

een

MBG813 / MBG817

Page 79: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

79

Wall Sounders MAS850LPS and MAS850LPSWP

Overview

The Menvier intelligent addressable wall sounderhas been developed specifically to operate withMenvier intelligent addressable control panels.

The high efficiency design of these wall soundersoffer excellent sound output levels despite the lowcurrent consumption.

MAS850LPSThe Menvier MAS850LPS is designed for wallmounting, has a choice of different tones and volumelevels, a built in short circuit isolator and is softaddressed for ease of installation.

MAS850LPSWPThe Menvier MAS850LPSWP is IP66 rated sosuitable for external and wash down areas, it isdesigned for wall mounting, has a choice of differenttones and volume levels, a built in short circuitisolator and is soft addressed for ease of installation.

Features

MAS850LPS• Loop powered• High efficiency design• Selectable tones controlled by

the panel• Adjustable volume controlled

by the panel• Simple clip fixing assembly

MAS850LPSWP• Weatherproof version (IP66)• Loop powered• High efficiency design• Selectable tones controlled by

the panel• Adjustable volume controlled

by the panel• Simple clip fixing assembly

Benefits• Low current consumption• First fix back box• Built in short circuit isolators

MAS850LPSWP weatherproof wall sounder MAS850LPS internal wall sounder

internal base

weatherproof base

Page 80: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

80

Intelligent Addressable Wall Sounders - MAS850LPS and MAS850LPSWP

Installation

MAS850LPS1. Installation is simple using first fix base.2. First fix base is fixed to mounting surface using

2 fixing holes.3. Cable entry can be rear or side.4. Connections are to connector block on main

sounder body.5. Main body is then clipped into position on

mounting base, body locks into position when pressed home.

MAS850LPSWP1. Installation is simple using first fix base.2. First fix base is fixed to mounting surface using

2 fixing holes.3. Cable entry can be rear or side.4. Connections are to connector block on main

sounder body.5. Main body is then fastened onto base, using

4 allen head screws (supplied).

Code DescriptionMAS850LPS Intelligent addressable internal wall sounderMAS850LPSWP Intelligent addressable weatherproof wall sounder

Product Codes

Code MAS850LPS MAS850LPSWP

Description Internal wall sounder Weatherproof wall sounder

Standards EN54 Pt3 EN54 Pt3

Specification

Operating Voltage 17V dc to 32V dc 17V dc to 32V dc

Standby Current < 320μA < 320μA

Tones (set by panel) Continuous: 984Hz Continuous: 984Hz

Pulsed: 984Hz / 0Hz pulse 1Hz Pulsed: 984Hz / 0Hz pulse 1Hz

Two tone: 644 / 984Hz @ 1Hz cycle Two tone: 644 / 984Hz @ 1Hz cycle

Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap

Sound Output @ +/-3dB Low volume : 87dB at <2mA Low volume : 87dB at <2mA

(set by panel) Medium volume : 93dB at <3mA Medium volume : 93dB at <3mA

High volume: 100dB @ <6mA High volume: 100dB @ <6mA

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Dimensions (H x W x D) 105mm x 105mm x 95mm 108mm x 108mm x 103mm

Weight 0.25kg 0.57kg

Ingress Protection IP42 IP66

Cable Entry Rear/side Rear/side

Compatibility

Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Technical SpecificationDimensions

Description H (mm) W (mm) D (mm)Internal 105 105 95Weatherproof 108 108 103

D

H

W

w

D

H

Internalwall sounder

Weatherproof wall sounder

System Functionality

MAS850LPS / MAS850LPSWP1. Volume is set by fire control

panel, no need to access sounder to alter setting.

2. Tone is set by fire control panel, no need to access sounder to alter setting.

Standard Connection

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of loop.

LOO

PIN

LOO

PO

UTCompatible Menvier

Intelligent Addressable Control Panel

- + - +E E

Scr

een

IN OU

T

Scr

een

MAS850LPS / MAS850LPSWP

Page 81: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

81

Wall Sounder Beacons MASB860 and MASB860WP

Overview

The Menvier intelligent addressable wall sounderbeacon has been developed specifically to operatewith the latest generation of Menvier intelligentaddressable control panels.

The high efficiency design offers excellent soundoutput levels despite the low current consumption.Whilst also includes a high powered LED beacon toprovide both audible and visual alarm signals.

MASB860The Menvier MASB860 is designed for wall mounting,has a choice of different tones and volume levels, abuilt in short circuit isolator and is soft addressed forease of installation.

MASB860WPThe Menvier MASB860WP is IP66 rated so suitablefor external and wash down areas, it designed forwall mounting, has a choice of different tones andvolume levels, a built in short circuit isolator and issoft addressed for ease of installation.

internal base

weatherproof base

Features

MASB860• Loop powered• Combined sounder beacon• High efficiency design• Selectable tones controlled by

the panel• Adjustable volume controlled

by the panel

MASB860WP• Weatherproof version (IP66)• Loop powered• Combined sounder beacon• High efficiency design• Selectable tones controlled by

the panel• Adjustable volume controlled

by the panel

Benefits• Low current• High efficency audio / visual

unit suitable for DDA compliance

MASB860WP weatherproof wall sounder beacon MASB860 internal wall sounder beacon

Page 82: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

82

Intelligent Addressable Wall Sounder Beacons - MASB860 and MASB860WP

Installation

MASB8601. Installation is simple using first fix base.2. First fix base is fixed to mounting surface using

2 fixing holes.3. Cable entry can be rear or side.4. Connections are to connector block on main.

sounder body.5. Main body is then clipped into position on

mounting base, body locks into position when pressed home.

MASB860WP1. Installation is simple using first fix base.2. First fix base is fixed to mounting surface using

2 fixing holes.3. Cable entry can be rear or side.4. Connections are to connector block on main

sounder body.5. Main body is then fastened onto base, using

4 allen head screws (supplied).

Code DescriptionMASB860 Intelligent addressable internal wall sounder beaconMASB860WP Intelligent addressable weatherproof wall sounder beacon

Product Codes

Code MASB860 MASB860WP

Description Internal wall sounder beacon Weatherproof wall sounder beacon

Standards EN54 Pt3 EN54 Pt3

Specification

Operating Voltage 17V dc to 32V dc 17V dc to 32V dc

Standby Current < 320μA < 320μA

Tones (set by panel) Continuous: 984Hz Continuous: 984Hz

Pulsed: 984Hz / 0Hz pulse 1Hz Pulsed: 984Hz / 0Hz pulse 1Hz

Two tone: 644 / 984Hz @ 1Hz cycle Two tone: 644 / 984Hz @ 1Hz cycle

Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap

Sound Output @ +/-3dB Low volume: 92dB at <6.5mA Low volume: 92dB at <6.5mA

(set by panel) Medium volume: 97dB at <7.5mA Medium volume: 97dB at <7.5mA

High volume: 100dB @ <8.5mA High volume: 100dB @ <8.5mA

Flash Energy 1Hz 1Hz

Environmental

Operating Temperature -10°C to +55°C -10°C to +55°C

Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH

Physical

Construction PC/ABS PC/ABS

Colour Red Red

Lens Colour Red Red

Dimensions (H x W x D) 105mm x 105mm x 95mm 108mm x 108mm x 103mm

Weight 0.21kg 0.32kg

Ingress Protection IP42 IP66

Cable Entry Rear/side Rear/side

Cable Size / Type 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC

Compatibility

Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Technical SpecificationDimensions

Description H (mm) W (mm) D (mm)Internal 105 105 95Weatherproof 108 108 103

Internalwall sounder beacon

Weatherproof wall sounder beacon

System Functionality

MASB860 / MASB860WP1. Volume is set by fire control

panel, no need to access sounder to alter setting.

2. Tone is set by fire control panel, no need to access sounder to alter setting.

Standard Connection

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of loop.

LOO

PIN

LOO

PO

UTCompatible Menvier

Intelligent Addressable Control Panel

- + - +E E

Scr

een

IN OU

T

Scr

een

MASB860 / MASB860WP

Page 83: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

83

Loop Connected LED Beacon MAB870

Overview

The Menvier intelligent addressable loop connectedLED beacon is available to complement audiblealarms for use in areas either where people may bepresent who have impaired hearing or areas withhigh ambient noise levels.

The Menvier MAB870 is designed for both wall andceiling mounting, has a built in short circuit isolatorand is soft addressed for ease of installation.

Features• High efficiency design• LED technology• Low profile design

Benefits• Low current• High efficency LED / visual

unit suitable for DDA compliance

MAB870 loop connected LED beacon

Page 84: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

84

Intelligent Addressable Loop Connected LED Beacon - MAB870

Installation1. Installation is simple using first fix base.2. First fix base is fixed to mounting surface via

2 fixings holes.3. Cable entry is from the rear.4. Connections are to connector block on beacon

body.5. Beacon body is pressed into first fix base then

twisted to lock into position.

Dimensions

D

Dia

Dia (mm) D (mm)95 53

Code DescriptionMAB870 Intelligent addressable loop connected LED beacon

Product Codes

Code MAB870

Description Loop connected LED beacon

Specification

Operating Voltage 17V dc to 32V dc

Standby Current < 250μA

Alarm Current < 4.1mA

Flash Frequency 1/2Hz

Environmental

Operating Temperature -10°C to +55°C

Humidity (Non Condensing) 0 to 95% RH

Physical

Construction PC/ABS

Colour Red

Dimensions (Dia x D) 95mm x 53mm

Weight 0.15kg

Ingress Protection IP54

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Technical Specification

System Functionality1. Utilises multiple LED's

combined with careful optical design to provide high intensityflash with low current consumption.

2. Low profile design for discreet installation.

Standard Connection

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Screen (Earth) must be continuous along entire length of loop.

LOO

PIN

LOO

PO

UTCompatible Menvier

Intelligent Addressable Control Panel

- + - +E E

Scr

een

IN OU

T

Scr

een

MAB870

Page 85: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

85

4 Way Sounder Controller Unit MPU424

Overview

An extensive range of interfaces are available tosupport the Menvier range of control panels,providing solutions for most design requirements.

The MPU424 4 way sounder controller unit is a loopconnected interface, which provides the facility topower and control 4 independent conventionalsounder circuits. This greatly simplifies installation inapplications where specialist sounders or beaconsare required by avoiding the need to connect themdirectly to the intelligent addressable control panel.

The unit only uses a single address yet each circuitcan be independently controlled according to therequired cause and effect programming.

Features• Quick and simple to install• Avoids the need to wire

conventional sounders backto the main panel

• 4 separate sounder circuits(0.4A)

• All outputs are independentlyprogrammable

• Battery backup via integralbattery

• Built in short circuit isolator• Built in power supply

Benefits• Plug and play, no hard

addressing required• Increased system integrity• No external short circuit

isolator required• Beacon and strobe can be

wired direct to the interfacethereby saving time and cabling

• Reduce cost of installation

MPU424 4 way sounder controller unit

Page 86: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

86

Intelligent Addressable 4 Way Sounder Controller Unit - MPU424

Code DescriptionMPU424 4 way sounder controller unit

Product Codes

Dimensions

W

H

D H (mm) W (mm) D (mm)300 300 74

Technical SpecificationCode MPU424

Description 4 channel sounder controller unit

Standards EN54 Pt4 & Pt17 2005

Specification

Operating Voltage 24V dc

Quiescent Current 250μA

Mains Supply Voltage 230V ac

Mains Current Consumption 0.4A

Battery 2 x 12 V, 4Ah, SLA

Standby Period 24 hours + 30 minutes ringing

Sounder Circuit Output 0.4A (max)

Sounder Load 1.6A (max)

Fire Relay Switching Voltage 30V dc

Switching Current 1A (resistive), 0.5 A (inductive) (max)

Environmental

Operating Temperature -10ºC to +45ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction ABS/steel

Dimensions (H x W x D) 300mm x 300mm x 74mm

Weight 5.4kg

Ingress Protection IP30

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Installation1. The sounder controller interface requires a local

unswitched 230V supply and incorporates a back up battery to maintain functionality under mains failure conditions.

2. Cable entry can be top or rear.3. Top entry is via 20mm conduit entries (pre-fitted

with blanking plugs for unused entries).4. Rear entry via substantial cable slot in metal back plate5. Top cover secured with tamper resistant screws

intelligent addressable loop

NOTES:1. Earth (Screen) cable must be connected to its adjacent earth terminal.2. The end of line resistor must always be fitted, even if input is not used.3. Sounder circuits are monitored for wiring open and short circuit.4. Output fire relay is a set of changeover volt free-contacts and is not monitored.5. This unit should only be finally connected to the 230V ac mains supply and battery, during system commissioning.

L N E E + - E + - E + - E + - E E-

--

-+

++

+

N/O

BATT

C N/C

OUT IN

230V ac mains

FIRE RELAY

back upbattery

6K8 6K8 6K8 6K8

Standard Connections

Page 87: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

87

Zone Monitor Unit MIU871

Overview

An extensive range of interfaces are available tosupport the Menvier range of control panels,providing solutions for most design requirements.

The MIU871 zone monitor unit connects zonesof suitable conventional detectors.

Features• Quick and simple to install• Accepts a zone of Menvier

conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base)

• Only takes a single address• Input monitored for open, short

circuits and ground trouble• Built in short circuit isolator

Benefits• Plug and play no hard

addressing required• Easy to expand a system using

existing wiring• No external short circuit

isolator required

MIU871 zone monitor unit

Page 88: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

88

Intelligent Addressable Zone Monitor Unit - MIU871

Code DescriptionMIU871 Zone monitor unit

Product Codes

Dimensions

W

H

D

H (mm) W (mm) D (mm)88 147 60

Technical SpecificationCode MIU871

Description Zone monitor unit

Standards EN54 Pt17 & Pt18 2005

Specification

Operating Voltage 18V dc to 30 V dc

Quiescent Current 2.8mA

Alarm Current 8mA

Current with 20 Detectors 3.4mA

Detector Load 20 detectors per zone (max)

Callpoint Load Unlimited

Environmental

Operating Temperature -10ºC to +60ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 88mm x 147mm x 60mm

Weight 0.23kg

Ingress Protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Installation1. Zone monitor unit is fixed to a deep double gang

back box (supplied).2. All connections are via heavy duty terminals.3. Cable entry can be top, bottom, side or rear.4. Can be surface or semi recessed mounted.

intelligent addressable loop

Callpoints can be connected with detectors on detector zone if preferred

CALLPOINTZONE

DETECTOR ZONELOOP

INOUT

6K

EOLM-1

OUT

IN

OUT

IN

--

--

+

+

++

+ + + +----E E E E

NOTES:1. Earth (Screen) cable must be connected to its adjacent earth terminal.2. The end of line resistor must always be fitted, even if input is not used.3. Maximum spur length - see BS5839 Pt:1 2002 for zone coverage.4. There is no maximum number of conventional callpoints allowed per zone output.5. Unit can only be used with its respective Cooper fire systems and compatible sensor and base.

Standard Connections

Note: The MIU871 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base)

Page 89: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

89

Shop Monitor Unit MSU840

Overview

An extensive range of interfaces are available tosupport the Menvier range of control panels,providing solutions for most design requirements.

The MSU840 shop monitor unit is designed toenable small units with conventional fire detection tobe fully integrated with a main intelligent addressablefire system. It is ideal for applications such asconnecting individual shop units into a mainshopping centre system. An external power supply isrequired to drive the 2 conventional sounder circuits.This power supply must be regulated for fire andcurrent limited.

Features• Quick and simple to install• Accepts a zone of Menvier

conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base)

• Provides 2 conventionalsounder circuits

• Only takes a single address• Includes output changeover

relay• Inputs monitored for open,

short circuits and groundtrouble

Benefits• Plug and play no hard

addressing required• Easy to expand a system using

existing wiring• No external short circuit

isolator required• Reduced installation cost by

using the 2 sounder circuits

MSU840 shop monitor unit

Page 90: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

90

Intelligent Addressable Shop Monitor Unit - MSU840

Code DescriptionMSU840 Shop monitor unit

Product Codes

Dimensions

W

H

D

H (mm) W (mm) D (mm)88 147 60

callpoints can be connected with detectors on detector zone if preferred

CALLPOINTZONE

DETECTOR ZONE

OutIn

+

FIRE RELAY

SOUNDER

EXTERNAL

PSU

MONITOR

24V

EXTERNAL

PSU

INPUT

LOOPINOUT

EOLM-124V dc output

power supply unit

FAULT CONTACTN/O

24VO/P

++-

-

OutIn +

+-

-

1 2

+ -- E

+-

N/O N/CC +-+ -+ -+-+-+-+-E E E E E

intelligent addressable loop

6K8 12K 12K

12K

Standard Connections

Technical SpecificationCode MSU840

Description Shop monitor unit

Standards EN54 Pt17 & Pt18

Specification

Operating Voltage 15V dc to 30V dc

Quiescent Current 3.4mA (max)

Quiescent Load Current 2.8mA (max)

Alarm Current 8mA (max)

Zone Circuits

Number Input Circuits 2

Zone Circuit 1 Callpoints only

Zone Circuit 2 Detectors and Callpoints

Number of Callpoints Unlimited

Callpoint Resistance 470Ω to 680Ω

Zone Circuit 1 EOL 6K8

Zone Circuit 2 EOL Active EOL

Number of Detectors 20 (max)

Short Circuit Fault Threshold 150Ω

Open Circuit Fault Threshold N/A active EOL

Sounder Circuits

Number of Sounder Circuits 2

Load per Output 300mA (max)

Sounder Circuit 1 and 2 EOL 12K

Relay

Fire Relay Single Pole C/O 1A - 30V dc

Environmental

Operating Temperature -10ºC to +60ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 88mm x 147mm x 60mm

Weight 1kg

Ingress Protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Note: The MSU840 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base)

Page 91: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

91

Spur Isolator Unit MSI850

Overview

An extensive range of interfaces are available tosupport the Menvier range of control panels,providing solutions for most design requirements.

The MSI850 spur isolator unit enables a spur ofintelligent addressable devices to be connected to amain analogue loop, the device is designed tosimplify installation of remote parts of buildings or forsimple system extensions.

Features• Quick and simple to install• Allows a spur of intelligent

addressable devices to be fed from the main loop

• Integral short circuit isolatorsfor the loop and the spur

• Automatically controlsaddressing sequence

• Built in short circuit isolator

Benefits• Plug and play no hard

addressing required• Easy to expand a system using

existing wiring• Reduced installation cost• No external short circuit

isolator required

MSI850 spur isolator unit

Page 92: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

92

Intelligent Addressable Spur Isolator Unit - MSI850

Code DescriptionMSI850 Spur isolator unit

Product Codes

Dimensions

W

H

D

H (mm) W (mm) D (mm)88 147 60

Technical SpecificationCode MSI850

Description Spur isolator unit

Standards EN54 Pt17 2005

Specification

Quiescent Current 170μA

Environmental

Operating Temperature -10ºC to +60ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 88mm x 147mm x 60mm

Weight 0.23kg

Ingress Protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Installation1. Please refer to current edition of BS5839-1 for

details of the maximum allowable area to be covered by a single zone.

2. Spur isolator unit is fixed to a deep double gang back box (supplied).

3. All connections are via heavy duty terminals.4. Cable entry can be top, bottom, side or rear.5. Can be surface or semi recessed mounted.

NOTES:1. Earth (Screen) cable must be connected to its adjacent earth terminal.2. For maximum spur length/load see BS5839 Pt1:2002.3. Unit can only be used with its respective Cooper fire systems and compatible sensor and base.

no end of lineresistor required

OUT

INSPUR

E

+

E

+

m

+

intelligent addressable loop

Standard Connections

Page 93: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

93

3 Channel I/O Unit MIO324

Overview

An extensive range of interfaces are available tosupport the Menvier range of control panels,providing solutions for most design requirements.

The MIO324 3 channel I/O unit enables simpleinterfacing between the fire system and otherequipment such as nurse call systems or accesscontrol systems. The inputs are fully monitored foropen and short circuits.

Features• Quick and simple to install• Soft addressed• 3 separate inputs and 3

separate outputs• Inputs monitored for open and

short circuits• Integral short circuit isolator

Benefits• Plug and play no hard

addressing required• Built in short circuit isolator no

additional hardware required• Unit takes 3 inputs, 3 outputs

- only 1 address required tomonitor and control saving onequipment and installation

MIO324 3 channel I/O unit

Page 94: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

94

Intelligent Addressable 3 Channel I/O Unit - MIO324 and MIO324T

Code DescriptionMIO324 3 channel I/O unitMIO324S 3 channel I/O unit, resets on silenceMIO324T 3 channel I/O unit, contains 3 separate addresses

Product Codes

Dimensions

W

H

D

H (mm) W (mm) D (mm)88 147 60

Technical SpecificationCode MIO324

Description 3 channel I/O unit

Standards EN54 Pt17 & Pt18 2005

Specification

Operating Voltage 18V dc to 30V dc

Quiescent Current 310μA

Maximum Switching Voltage 50V ac or 30V dc

Output Relay Contact Rating 1A at 30V resistive, 0.5A inductive

Environmental

Operating Temperature -10ºC to +60ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 88mm x 147mm x 60mm

Weight 0.23kg

Ingress Protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Installation1. 3 Channel input output unit is fixed to a deep

double gang back box (supplied).2. All connections are via heavy duty terminals.3. Cable entry can be top, bottom, side or rear.4. Can be surface or semi recessed mounted.5. Relay contacts are rated at 24V dc 1A.

intelligent addressable loop

NOTES:1. Earth (Screen) cable must be connected to its adjacent earth terminal.2. The end of line resistor must always be fitted, even if input is not used.3. Input circuit is monitored for wiring open and short circuit.4. Output relay is a set of changeover volt free-contacts and is not monitored.

5K6 5K65K6

22K 22K 22K

LOOP

IN OUT INPUTS

OUTPUTSN/O C N/C N/O C N/C N/O C N/CE E- + - + - + - + - +

Standard Connections

Page 95: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

95

230V ac Relay Unit MIO1240

Overview

An extensive range of interfaces are available tosupport the Menvier range of control panels,providing solutions for most design requirements.

The MIO1240 230V ac relay unit enables simpleinterfacing between the fire system and otherequipment such as nurse call systems or accesscontrol systems.

The ability of the output unit to switch mains alsomakes the unit ideal for plant control or mainspowered door holders.

The input is monitored for open and short circuitstherefore can be used for fire input applications suchas monitoring sprinkler flow switches.

Features• Quick and simple to install• Soft addressed• Only takes a single address• Integral short circuit isolator

Benefits• Plug and play no hard

addressing required• Easy to expand a system using

existing wiring• No external short circuit

isolator required

MIO1240 relay unit

Page 96: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

96

Intelligent Addressable - 230V ac Relay Unit - MIO1240

Installation1. Mains rated input relay is designed for surface

fixing.2. All connections are via heavy duty terminals.3. Cable entry can be top, bottom or side.4. Output relay contacts are rated at 230V ac.

Code DescriptionMIO1240 230V ac relay unit

Product Codes

Dimensions

W

H

D H (mm) W (mm) D (mm)129 180 60

Technical SpecificationCode MIO1240

Description 230V ac relay unit

Standards EN54 Pt17 & Pt18 2005

Specification

Operating Voltage 18V dc to 30V dc

Quiescent Current 310μA

Maximum Switching Voltage 250V ac or 30V dc

Maximum Switching Current 8A

Environmental

Operating Temperature -10ºC to +60ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 129mm x 180mm x 60mm

Weight 0.6kg

Ingress Protection IP65

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

intelligent addressable loop

IN OUTSPUR INPUT

volt-free output 230V rated

5K6

22K

E C N/C N/OE E- --+ ++

NOTES:1. Earth (Screen) cable must be connected to its adjacent earth terminal.2. The end of line resistor must always be fitted, even if input is not used.3. Input circuit is monitored for wiring open and short circuit.4. Output relay is a set of changeover volt free-contacts and is not monitored.

Standard Connections

Page 97: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

97

Micro Zone Monitor Unit MIU872

Overview

An extensive range of micro interfaces are availableto support the Menvier range of control panels,providing solutions for most design requirements.

The MIU872 is a single zone input, soft addressed,micro interface, incorporating integral short circuitisolators.

It is fully compatible with the current range of Menvierintelligent addressable fire detection panels.

It is suitable for interfacing a zone of up to 20conventional Menvier detectors onto a Menvierintelligent addressable control panel.

It will operate with any Menvier conventional detectorin configuration with a schottky diode type base.

Features• Quick and simple to install• Accepts a zone of Menvier

conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base)

• Only takes a single address• Input monitored for open and

short ground trouble• Active end of line monitoring• Built in short circuit isolator

Benefits• Plug and play no hard

addressing required• Easy to expand a system using

existing wiring• No external short circuit

isolator required

MIU872 micro zone monitor unit

Page 98: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

98

Intelligent Addressable Micro Zone Monitor Unit - MIU872

Installation1. Suitable for use with any Menvier conventional detector.2. Connections suitable for single strand fireproof cable up.

to 2.5mm2.3. Loop and output cable screen must be connected to

interface earth terminals.

Note: No addressing of the interface is required(see control panel operation for details)

Technical SpecificationCode MIU872

Description Micro zone monitor unit

Standards EN54 Pt17 & Pt18

Specification

Operating Voltage 18V dc to 30V dc

Quiescent Current 2.6mA (nom)

Load With 20 Detectors,

and Unlimited Callpoints 3.2mA (nom)

Alarm Load With 20 Detectors,

and Unlimited Callpoints 8.0mA (nom)

Detector Zone

Detectors per Zone 20 (max)

End of Line Monitor Active end of line unit - EOLM-1

Fire Input Trigger Resistance 680Ω (nom)

Short Circuit Fault

Threshold Resistance 100Ω (max)

Open Circuit Fault

Threshold Resistance 39KΩ (min)

Environmental

Operating Temperature -10ºC to +60ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 65mm x 35mm x 18.5mm

Weight 0.28kg

Ingress Protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Code DescriptionMIU872 Micro zone monitor unit

Product Codes

LOOP IN

LOOP OUT

IN+

IN-

INPUTmaximum 20 Cooper conventional detectors

EO

LM-1

EARTH

Dimensions

W H

D

H (mm) W (mm) D (mm)65 35 18.5

Standard Connections

Mounting Details

37.5mm

22m

m

Note: The MIU872 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base)

Page 99: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

99

Micro Single Channel Output Units MCOM

Overview

An extensive range of micro interfaces are availableto support the Menvier range of control panels,providing solutions for most design requirements.

The MCOM is a single output, soft addressed, microinterface, incorporating integral short circuit isolators.It is extremely compact and therefore ideal forincorporation into other equipment.

The MCOM is fully compatible with the current rangeof Menvier intelligent addressable fire control panels.

It is suitable for switching low voltage (24V dc at 1Amaximum), via a set of non latching relay contacts.

It is suitable for switching HVAC control circuits, plantshutdown control circuits, fire door closure etc.

Optional Variants

The MCOM-R gives a 5 second pulse on reset.

The MCOM-S is identified by the panel as a sounder.Dose not reset on silence, resets on reset only.

MCOM-SMCOM-S micro single channel output unit

Features• Quick and simple to install• Compact size• Soft Addressed• Integral short circuit isolator

Benefits• Plug and play no hard

addressing required• No external short circuit

isolator required

MCOM-R micro single channel output unit MCOM micro single channel output unit

Page 100: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

100

Intelligent Addressable Micro Single Channel Output Units

Code DescriptionMCOM Micro single channel output unit (recognised as output unit)MCOM-S Micro single channel output unit (recognised as sounder)MCOM-R Micro single channel output unit (5 second reset pulse)

Product Codes

Installation1. Suitable for switching 24V dc control circuits

(fire door retainers etc).2. Connections suitable for single strand fireproof

cable up to 2.5mm2.3. Loop and output cable screen must be connected

to interface earth terminals.4. The relay output is a set of change over,

non-latching, volt free contacts which are non monitored.

Note: No addressing of the interface is required(see control panel operation for details)

Technical SpecificationCode MCOM

Description Micro single channel output unit

Standards EN54 Pt17 & Pt18

Specification

Operating Voltage 18V dc to 30V dc

Quiescent Current 310μA

Output Relay

Switching Voltage 24V dc to 30V dc

Contact Rating 1A

Switching Power 30 Watts

Environmental

Operating temperature -10ºC to +60ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 65mm x 35mm x 18.5mm

Weight 0.078kg

Ingress protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

LOOP IN

LOOP OUT

N/O

N/C

OUTPUT

C

Standard Connections

Dimensions

W H

D

H (mm) W (mm) D (mm)65 35 18.5

Mounting Details

37.5mm

22m

m

Page 101: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Intelligent Addressable Product Range

101

Micro Single Channel Input Units MCIM

Overview

An extensive range of micro interfaces are availableto support the Menvier range of control panels,providing solutions for most design requirements.

The MCIM is a single input, soft addressed microinterface, incorporating integral short circuit isolators.It is extremely compact and therefore ideal forincorporation into other equipment.

The MCIM is fully compatible with the current rangeof Menvier intelligent addressable fire control panels.

It is suitable for monitoring a set of normally open,volt free contacts such as sprinkler system flowswitches, auxiliary panel fire/fault signals as well asnon fire input signals such as flow valve opencontacts, generator start up, fire door closed etc.

Optional Variants

The MCIM-NF is designed for non-fire applications.

The MCIM-C is identified by the panel as a callpoint.

Features• Quick and simple to install• Compact size• Soft Addressed• Integral short circuit isolator

Benefits• Plug and play no hard

addressing required• No external short circuit

isolator requiredMCIM-C micro single channel output unit

MCIM-NF micro single channel output unit MCIM micro single channel output unit

Page 102: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

102

Intelligent Addressable Micro Single Channel Input Units

Code DescriptionMCIM Micro single channel input unit (recognised as input unit)MCIM-C Micro single channel input unit (recognised as callpoint)MCIM-NF Micro single channel input unit (non fire input)

Product Codes

Technical SpecificationCode MCIM

Description Micro single channel input unit

Standards EN54 Pt17 & Pt18

Specification

Operating Voltage 18V dc to 30V dc

Quiescent Current 310μA

Inputs

Trigger Resistance 5K6Ω

End of Line Resistor 22KΩ

Short Circuit Fault

Threshold Resistance 1KΩ

Open Circuit Fault

Threshold Resistance 33KΩ

Environmental

Operating temperature -10ºC to +60ºC

Humidity (non condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 65mm x 35mm x 18.5mm

Weight 0.078kg

Ingress protection IP40

Compatibility

Suitable for use with Menvier intelligent addressable fire systems

Installation1. Inputs monitored for open and short circuit fault

conditions.2. Suitable for monitoring normally open volt free contacts

(flow switches etc).3. Connections suitable for single strand fireproof cable up

to 2.5mm2.5. Loop and output cable screen must be connected to

interface earth terminals6. The end of line monitoring resistor, must always be fitted

at the end of the input wiring, if the input is unused the end of line resistor must be fitted at the interface input terminals.

Note: No addressing of the interface is required(see control panel operation for details)

LOOP IN

LOOP OUT

IN+

IN-

INPUT

5K6

EARTH

22K

Standard Connections

Dimensions

W H

D

H (mm) W (mm) D (mm)65 35 18.5

Mounting Details

37.5mm

22m

m

Page 103: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Ancillaries and Test Equipment

103

Heavy Duty Relay Unit MAR724

Overview

The Menvier heavy duty relay unit is designed forinterfacing heavy loads such as door release unitsor plant shut down equipment with fire alarmsystems.

It is simple to fix and install and the neat unobtrusivedesign makes it suitable for use in a wide range ofareas.

The heavy duty relay is powered by 24V dc externalsupply and is provided with 2 separate sets ofchangeover contacts. The front mounted status LEDilluminates when relay is energised.

Features• Simple to install• Visible status indication LED• Double pole change over

contacts

Benefits• Low current consumption• 230V ac rated contacts• Will switch up to 10A (resistive)

MAR724 heavy duty relay

Page 104: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

104

Heavy Duty Relay Unit - MAR724

Code MAR724

Description Heavy duty relay unit

Specification

Coil Rating 24V dc 10mA

Contact Rating 10A at 240V ac or 30V dc

Contacts 2 x sets of changeover contacts

Environmental

Operating Temperature -10°C to +55°C

Humidity (Non Condensing) 0 to 95% RH

Physical

Construction PC/ABS

Dimensions (H x W x D) 89mm x 150mm x 58mm

Weight 0.24Kg

Ingress Protection IP30

Compatibility

Suitable for use with Menvier fire systems

Technical Specification

Installation1. Heavy duty relay unit fixes to a standard deep

double gang back box (supplied).2. Cable entry is via back box, cables are terminated

into heavy duty terminals on relay PCB.

Interface Options1. Relay is powered by an external 24V dc supply.

Dimensions

W

H

D

H (mm) W (mm) D (mm)89 150 58

Standard Connection

Compatible Menvier Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

+NC

24V dc OUTPUT

C NO NC C NO -

RELAY 1 RELAY 2

MAR724

Code DescriptionMAR724 Heavy duty relay unit

Product Codes

Page 105: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Ancillaries and Test Equipment

105

Power Supply Unit FX1A

Overview

The FX1A is a 24V dc battery backed power supplyunit complete with back up batteries.

The output is continuous and transition from mains tobattery is without break in the output. It is monitoredand has local fault indication as well as volt freecontacts for remote fault signalling, making it ideal asa general purpose power supply for fire alarmapplications.

Features• Compact enclosure• Integral battery• Fault indicator• Remote fault contact

Benefits• Simple to use• Secure steel enclosure• Built in battery back up

FX1A power supply unit

Page 106: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

106

Power Supply - FX1A

Code FXA1

Description Power supply unit

Standards EN54 Pt4

Specification

Maximum Continuous Load 0.8A

Maximum Intermittent Load 1.0A

Standby Batteries 2 x 12V 2.1 Ah

Fault Relay Contact Rating 3A at 24V dc

Fuse Protection Mains input, charger output, system output

Output Voltage (mains healthy) 27.5V dc

Output Voltage (mains failed) 20.4 - 24V dc dependant on battery status

Physical

Construction Mild steel

Dimensions (H x W x D) 230mm x 323mm x 77mm

Ingress Protection IP30

Compatibility

Suitable for use with Menvier fire systems

Technical Specification

Installation1. Enclosure is designed for wall mounting.2. 2 x 20mm knockouts are provided for cable entry

at the top of the enclosure.3. A fused terminal block is provided for mains

supply connection.4. Output is protected by internal 1.5A fuse.

Dimensions

WD

H

H (mm) W (mm) D (mm)230 323 77

System Functionality1. FX1A power supply provides a

maximum output of 1A.2. Output is used to supply any

connected load and also torecharge the integral batteries.

3. To enable batteries to be charged correctly maximumcontinuous external load should not exceed 0.8A.

4. LED indicators are provided to signify:• Mains healthy• System fault• Output supply fault• Charger output fault

5. Mains healthy and system faultLED's are visible withoutremoving front cover.

Code DescriptionFX1A 24V dc power supply unit, with battery backupFASP0429 24V dc power supply unit, no battery backup

Product Codes

Page 107: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Ancillaries and Test Equipment

107

Loop Tester Kit LP800KIT

Overview

The LP800 loop tester is a hardware / softwarecombination that can be used to test, commissionand fault find a loop of up to 200 Menvier intelligentaddressable devices (sensors, sounders, ancillarydevices) without having to connect the loop to theMenvier intelligent addressable fire panel.

The loop tester is connected between the loop andPC. It allows the engineer to quickly identify andlocate any loop device that is operating outside itsoperating conditions by varying the alarm thresholdof any loop device (alarm, prealarm and fault).

The loop tester hardware requires a free serial port onthe PC, either internal or via a USB extension, amains power supply and a direct connection to thedevice loop.

LP800KIT loop tester kit box

Features• Pre-addressing: Identifies all

Menvier field devices anddetermines their address and device type

• Analogue Values: Constantly displays in real time the analogue value of all Menvier loop devices in order todetermine their status

• Test LED: This command operates the LED of anyinputs (detector/call points) as well as controls the outputs of sounders and output modules

• Device Settings: Analogue values of all devices can beinterpreted according to ranges which can be set andaltered by the user (OK, pre-alarm, fire)

• Event Log: A history of events can be stored from the date the application was started

• Soft addressing: Automatically assigns a new, and potentially different, address to every device found on the loop

LP800KIT loop tester kit in box LP800KIT loop tester

Code DescriptionLP800KIT Programmer

Product Codes

Page 108: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

108

Ancillaries and Test Equipment

Addressable Device Programmer CF800PROG

Overview

The CF800PROG programmer is a versatile tool toaid the installation, commissioning, maintenanceand servicing of current addressable devices andfire alarm systems.

This unit is light, robust and easy to operate using auser friendly menu structure on 2 x 40 character LCDdisplay. It is powered from a single PP3 size, heavyduty battery or an external supply.

The programmer has a built in addressable base aswell as two external terminals for use with all othercurrent addressable ancillary devices.

Features• Reads addresses• Writes addresses• Reads analogue values• Tests devices• Deletes addresses• Programmes the 3 heat

settings

CF800PROG programmer, back

CF800PROG addressable device programmer

Code DescriptionCF800PROG Addressable device programmer

Product Codes

Page 109: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Notes

109

Page 110: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

110

Notes

Page 111: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

Global PresenceCooper Industries is a diversified global manufacturerof world-class electrical products, components andtools, with 2009 revenues of $4.5 billion. TheCompany has seven operating divisions withmanufacturing facilities in 23 countries, and employsmore than 25,000 people throughout the world.

With its broad range of products and global brandsincluding; Bussmann electrical and electronic fuses;Crouse-Hinds and CEAG explosion-proof electricalequipment; Halo, Metalux, Menvier and Cromptonmains and emergency luminaires; Kyle and McGraw-Edison power systems products; Menvier and JSBfire systems, Cooper is uniquely positioned forseveral long-term growth trends, including the currentglobal infrastructure developments, improvements toenhance the reliability and productivity of the electricgrid, the increased demand for energy-efficientproducts and the need for improved electrical safety.

Principles• To observe all environmental laws and regulations• To respond effectively to environmental concerns

involving Cooper facilities and products• To minimize and, wherever possible, to eliminate

the generation of all wastes• To conduct operations in a manner that

demonstrates respect for the environment• To cooperate with federal, state and local

governments in developing scientifically based environmental standards

• To encourage the development of environmentally sound procedures and to conduct business with the best-available technology

• To maintain environmental monitoring programs that ensure compliance with governmental requirements and these principles

• To provide training programs that emphasize the individual's responsibility for sound environmental decisions

In line with this global policy Cooper Lighting andSafety Ltd has an Environmental Management Policywhich satisfies the requirements of

BS EN 14001:2004

Cooper IndustriesEnvironmental PolicyOn May 1, 1990, Cooper Industries issued a formal policy to affirm itscommitment to the environment. The principles of this policy, reinforcestandards of operation already in place and remind employeesthroughout the world that environmental considerations have the highestpriority at Cooper.

The CarbonTrust StandardIn 2010 the UK facilities of Cooper Industries have been awarded theCarbon Trust Standard after taking action on climate change bymeasuring, managing and reducing its carbon emissions by 17%. TheCarbon Trust Standard recognises organisations for real carbonreduction. Based on a rigorous, independent assessment, it certifies thatorganisations have measured, managed and reduced their carbonemissions across their own operations, and are committed to reducingthem year on year.

Page 112: Menvier Fire  · PDF fileof Menvier fire detection products suitable ... integrated fire detection and alarm system. ... A full set of installation and user instructions is

The trade names and brand names contained herein are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use theCooper Trademarks without the prior written consent of Cooper Industries.

Cooper Industries plc600 Travis, Suite 5600Houston, TX 77002 - 1001T: 713 - 209 - 8400www.cooperindustries.com

SalesT: +44 (0)1302 303 999F: +44 (0)1302 303 333E: [email protected]

Technical and QuotationsT: +44 (0)1302 303 350F: +44 (0)1302 303 332E: [email protected]

ServiceT: +44 (0)1302 303 352F: +44 (0)1302 303 332E: [email protected]

ExportT: +44 (0)1302 303 344F: +44 (0)1302 303 345E: [email protected]

Cooper Safety Fire SystemsCooper Lighting and Safety LtdWheatley Hall RoadDoncasterSouth YorkshireDN2 4NBUnited Kingdom

www.cooperfire.com

Conditions of saleAll goods supplied are subject to the company’s general conditions of sale which are available on request.

Trade DescriptionsAll descriptions represent only particulars of the goods to which they apply and do not form part of any contract. The company reserves the right to change specificationwithout prior notification or public announcement.

®2011 Cooper Lighting and SafetyAll rights reserved.

Publication reference: CFS0018_UK_R1