41
INSTALLATION MANUAL MEMOCam ® MEMOCam ® PLUS MEMOCam ® DVR MEMOCam ® PLUS/S

MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

  • Upload
    vonhu

  • View
    215

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

INSTALLATION MANUAL

MEMOCam®

MEMOCam®PLUS

MEMOCam®DVR

MEMOCam®PLUS/S

Page 2: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

Version 3.2.001

PN/V7122550

Page 3: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

Copyright Video Domain Technologies Ltd. 2003

The information in this manual was accurate and reliable at the time of its release. However, Video Domain Technologies Ltd. reserves the right to change the specifications of the product described in this manual without notice at any time. As such, the descriptions and data included in this document may not be current. Video Domain Technologies Ltd. assumes no responsibility for any inconsistencies between the actual product and this manual's description of it. Any party electing to use this manual does so with the full knowledge of the possibility of such inconsistencies and takes full responsibility for any consequences that may arise while installing and/or using this product.

Video Domain Technologies Ltd. holds the copyright to this manual. All rights are reserved. No part of this publication may be reproduced or transmitted in any form or by any means without prior written consent from Video Domain Technologies Ltd.

Disclaimer

Video Domain Technologies Ltd. makes no warranties regarding the content of this document. Video Domain Technologies Ltd. reserves the right to alter, modify and revise the specification without notice. Video Domain Technologies Ltd. assumes no responsibility for any errors contained herein.

The customer should note that in the field of multimedia there are a number of patents held by various parties. It is the responsibility of the user to assure that a particular implementation does not infringe on those patents. Video Domain Technologies Ltd. does not indemnify the user from any patent or intellectual property infringement.

Registered Trademarks

All other proprietary names mentioned in this manual are the trademarks of their respective owners.

Video Domain Technologies Ltd.

www.vdomain.com

Page 4: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

Manufacturer: Video Domain Technologies Ltd. Model: MemoCam Rated voltage(s): 12VDC Current(s) (or power): 0.5 A

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

(2) This device must accept any interference received, including interference that may cause undesired operation.

This Class A/B digital apparatus complies with Canadian ICES-003.

Cet appareil numẻrique de la classe A/B est conforme ả la norme NMB-003 du Canada.

FCC

Changes or modifications not expressly approved by Video Domain could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.

Page 5: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

TABLE OF CONTENTS

Introduction .................................................................... 1

Main Features ................................................................................3

Installing the MemoCam Unit ......................................... 5

System Requirements.....................................................................5 PC Minimum Requirements ........................................................5 Pocket PC Minimum Requirements .............................................5

Packing List ....................................................................................6 Mounting the Device......................................................................7 Connecting the Power Supply ........................................................9 Optional Connections (Advanced Features)..................................10

MemoCam Terminal Blocks ......................................................11 Terminal Wire Connections.......................................................12 Connecting an External Device .................................................14

Operating the MemoCam.............................................. 17

Using the Multimedia Card ..........................................................17 LED Indicators ..............................................................................18 Audible Signals (Beeps) ................................................................19

Using the Remote Control ............................................. 21

Arming the MemoCam.................................................................22 Disarming the MemoCam ............................................................22 Manual Image Recording – Snapshot...........................................23 Using the Video Output ...............................................................23

Troubleshooting ............................................................ 25

Page 6: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

Technical Specifications .................................................27

Dimensions ..................................................................................27 Camera ........................................................................................27 Multimedia Card ..........................................................................28 Multimedia Card Reader ..............................................................28 Infrared Motion Detector – Dual Element PIR...............................29 Terminal Connectors and Switches...............................................29 Power Supply ...............................................................................29

Appendix for MemoCam Plus/S .....................................30

RS-485 ID Settings .......................................................................30 Termination Dipswitch .................................................................33 Wiring RS-485 ..............................................................................33 Host Device ..................................................................................34 Wiring RS-232 ..............................................................................34

Glossary .........................................................................35

Page 7: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

1

INTRODUCTION

This manual is applicable for the following products:

MemoCam

MemoCam Plus

MemoCam DVR

MemoCam Plus/S

MemoCam is a complete stand-alone digital CCTV system in a single device. It is a high performance camera with automatic digital recording features contained in a single compact enclosure.

The MemoCam system includes a CCD camera, a video compression engine, a removable Multimedia card, and a Passive Infrared (PIR) detector.

The MemoCam unit automatically records events on the Multimedia card following an alarm trigger. The trigger can be activated by an external open contact or the internal PIR detector. Single snapshots can be recorded using the external remote control unit.

MemoCam Plus supports the use of two additional cameras, video motion detection (VMD), and video output capability.

Figure 1. MemoCam Plus

Page 8: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

2

MemoCam DVR does not contain a camera or PIR, but can support up to three external cameras, video motion detection (VMD), and video output capability.

Figure 2. MemoCam DVR

All images are stored in the Multimedia card. To analyze the recorded events on a PC, the Multimedia card is removed from the MemoCam unit and images are downloaded using a Multimedia card reader and the MemoCam software.

One or more stand-alone units can be placed at different site locations. The units are configured using the Multimedia card. The MemoCam is activated using the remote control unit.

Figure 3. The MemoCam System

Page 9: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

3

Main Features The MemoCam system has the following features:

Stand-alone integrated CCTV system packaged in a standard PIR detector case (MemoCam DVR contains no internal camera or PIR).

B/W camera – Color option available (MemoCam, MemoCam Plus).

CCIR, EIA B/W video inputs (2 for MemoCam Plus, 3 for MemoCam DVR).

Two relays for activation of external devices.

Automatic recording upon trigger.

Standard 16 MB memory card can contain up to 1500 recorded images. 64 MB card can contain up to 6000 images.

Automatic setup using the Multimedia card.

User defined image quality, frame rate, and recording time per event, delay between frames, and more.

Fixed or cyclic recording modes.

Pre-alarm recording.

Image integrity protection.

Event and Arm/Disarm Scheduler.

Video motion detection (MemoCam Plus, DVR).

Multi camera support (MemoCam Plus, DVR).

Video out (MemoCam Plus, DVR).

Remote Control unit.

Covert case.

The stand-alone MemoCam unit replaces the classic Time Lapse VCR + PIR detector + Camera equipment set.

Modular solution from single camera to multiple site and multiple camera systems.

Easy to use PC software.

Economical system expansion.

Page 10: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation
Page 11: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

5

INSTALLING THE MEMOCAM UNIT

In addition to the system requirements described below, installation of the MemoCam unit will require a screwdriver and two screws. Depending on the hardness of the wall, a drill and two screw-anchors may also be required.

System Requirements The following are the minimum system requirements for installing the MemoCam viewer application on a PC, or the Pocket PC viewer application on a pocket PC.

PC Minimum Requirements

CPU Pentium II 200Mhz or higher.

RAM 16 MB or higher.

Graphic adapter Super VGA or higher

Display resolution 640x480, 16 bit or higher.

Operating systems Windows 95, 98, 2000, ME, NT, or XP with Internet Explorer TM 5.0 or higher

Multimedia card reader

Pocket PC Minimum Requirements

CPU ARM (or compatible)

RAM 16 MB or higher

Display resolution 320x240, 16 bit or higher

Operating systems Windows CE 3.0 or higher

Multimedia card reader

Page 12: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

6

Packing List The MemoCam Kit includes the following items:

MemoCam unit.

16 MB Multimedia card.

Protective card cover (MemoCam Plus only).

Mounting Kit (brackets).

Power Supply.

IR Remote Control Unit and 2 AAA Batteries.

Software CD.

MemoCam Installation Manual (this manual).

MemoCam Quick Setup Guide.

MemoCam software CD.

Page 13: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

7

Mounting the Device The MemoCam unit is wall-mounted. However, it is not necessary to wall-mount the MemoCam DVR.

Begin by selecting a mounting location on the wall. Choose a location most likely to intercept an intruder. Make sure that the MemoCam unit’s power cord can reach a nearby power receptacle. If necessary, an extension cord can be used.

The PIR is most sensitive in detecting sideways motion.

The MemoCam unit performs best in steady light and stable temperature.

Avoid the following locations:

Facing direct sunlight or light sources.

Facing areas subject to rapid quick temperature changes.

Areas with air ducts or substantial air flows.

Facing areas with high light contrast.

A MemoCam mounting bracket is included with the MemoCam unit.

Figure 4. Mounting Bracket

Page 14: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

8

To mount the MemoCam unit:

1. Loosen the two pieces of the mounting bracket without separating them. The two sections of the bracket should swing freely.

2. Place the wall-mount section of the bracket on the desired location on the wall, and mark the drill points through the two fastener holes.

3. Drill the holes (if necessary) and attach the bracket to the wall with screws.

4. Retighten the two mounting bracket pieces so that the MemoCam Mount section can still be rotated with slight pressure.

5. Clip the upper part of the MemoCam unit’s holder (1) to the bracket and rotate, as indicated in Figure 5, until the MemoCam unit snaps into place (2).

6. Adjust the position of the MemoCam unit by moving it slowly up/down and left/right to the desired position.

7. Remove the MemoCam unit carefully from the bracket without changing the bracket position.

8. Tighten the two mounting bracket pieces firmly to prevent further movement.

9. Re-attach the MemoCam unit to the bracket as indicated in step 5 above.

Figure 5. Mounting the MemoCam Unit

Page 15: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

9

Connecting the Power Supply Connect the power adapter to the power connector coming out of the MemoCam unit.

Plug the power supply unit into a wall socket. The MemoCam status LED indicators illuminate (refer to LED Indicators on page 18 for details).

Figure 6. MemoCam Unit – Rear View

Page 16: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

10

Optional Connections (Advanced Features) Optional security system devices can be connected to the MemoCam unit. These external elements include cameras, video monitors (in MemoCam Plus and DVR), battery backups, detectors, and control panels.

To connect external elements to the MemoCam unit, you must remove the MemoCam unit’s front cover by unscrewing the holding screw on the bottom end of the device as shown in Figure 7.

Figure 7. Removing the MemoCam Front Cover

Page 17: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

11

MemoCam Terminal Blocks

The MemoCam unit’s printed circuit board contains a wire-connection terminal block, six separate terminal blocks and a jumper as shown in Figure 8.

Figure 8. MemoCam Plus/DVR Terminal Block

MemoCam does not have the video terminals.

MemoCam DVR has a factory-connected cable for Video In 1.

Page 18: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

12

Terminal Wire Connections

The terminal block wire connections are described in Table 1.

The terminal block can be used to connect the MemoCam power sources as follows:

Single Power Source – The MemoCam unit is powered by a 12VDC, 500mA power supply that feeds both the PIR and the video circuits. The MemoCam DVR is powered by a 12 VDC, 400mA power supply.

Dual Power Source – The MemoCam unit can be connected to a normal power supply and a backup power source. In this configuration, when the ordinary power supply is not available, the backup battery powers only the PIR, and thus can still activate an alarm. The MemoCam cannot record images in backup power mode.

The jumper is used as follows:

Installed (Default) – The MemoCam unit is powered by a single DC power supply connected between terminals 1 and 2.

Not Installed – In this mode, the MemoCam unit can be connected to a backup power supply such as UPS or a battery from an alarm panel, in addition to the main power supply. The backup power supply is connected between terminals 1 and 2, feeding the PIR, while the video circuits can be fed by an ordinary power supply via terminals 1 and 3.

Page 19: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

13

Table 1. Terminal Block Connectors

Terminal Description

1 GND – Common power supply ground.

2 +12V – Connects to the positive output of the ordinary power supply when jumper J1 is installed or to the backup power supply when jumper J1 is not installed.

3 +12VID – Connects to the positive output of the ordinary power supply. Use only when jumper is not installed (open).

4 and 5 RELAY 1 terminals, which are Normally Closed (N.C.) contacts. This relay is activated by the PIR, and can be used to activate an external alarm device. When triggered by detected movement, the relay N.C. contact opens for 1.8 seconds (standard).

6 and 7 RELAY 2 terminals, which are Normally Open (N.O.) contacts. This relay is software-activated. When tripped, the relay N.O. contact opens for a pre-defined period that is user selectable.

Used to switch on an external device such a video recorder.

1 and 8 IN1 Input – Connects an auxiliary device such as a door or window switch.

9 and 10 Tamper terminals, which are Normally Closed contacts that open when the MemoCam cover is removed. They can be connected to an external alarm or other device.

Other Terminal Blocks (MemoCam Plus and DVR)

IN2 and GND Connects an auxiliary device for external alarm triggers.

IN3 and GND Connects an auxiliary device for external alarm triggers.

V_IN2 and GND

Connects to an external camera.

V_IN3 and GND

Connects to an external camera.

V_GND and VIDEO OUT

Connects to an external video monitor.

TX and RX Reserved (MemoCam Plus only).

Page 20: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

14

In MemoCam DVR only, connect camera1 using the external video plug as shown in Figure 9.

Figure 9. MemoCam DVR External Connectors

The same video standard CCIR or EIA must be used for all cameras (internal and external in MemoCam Plus, and all external cameras in MemoCam DVR).

Connecting an External Device

To connect an external device to the MemoCam unit:

1. Open one of the pre-marked wire access holes (Figure 10) on the top end of the MemoCam unit.

2. Insert the device wires through the wire access hole.

3. Connect the wires (Figure 11) from the connectors on the terminal block as shown in Figure 8.

If you are connecting a backup power device, ensure that the jumper is not connected.

4. Reposition the unit’s cover and fasten the holding screw (Figure 7).

Page 21: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

15

Figure 10. MemoCam Wire Access Knockout Holes

Figure 11. Connecting the Wires

Page 22: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation
Page 23: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

17

OPERATING THE MEMOCAM

The MemoCam has default configuration parameters that allow for immediate use upon initial installation. You can also control the MemoCam by the parameters that you configure onto the Multimedia card using the Multimedia card reader. Refer to the MemoCam Software Manual for more details.

Using the Multimedia Card When first using a new Multimedia card, format the card as follows:

1. Ensure that the MemoCam unit is powered.

2. Insert the Multimedia card into the card slot on the bottom of the MemoCam unit as shown in Figure 12. Verify that the card is securely locked into the slot.

3. Wait until the Multimedia Card Status (left) LED turns off.

4. Remove the Multimedia card by pushing it gently into the card slot and quickly releasing it. This will unlock the card from the slot.

5. Insert the Multimedia card into the Card Reader that is connected to your PC. You can now configure the MemoCam in accordance with the procedures in the MemoCam Software Manual.

Figure 12. Inserting the Multimedia Card

Page 24: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

18

Your MemoCam unit is supplied with a protective cover for the Multimedia card slot. You must remove this cover before attempting to insert or remove the Multimedia card.

The MemoCam must be in disarm mode before you remove the Multimedia card.

LED Indicators The MemoCam unit contains three LED status indicators.

The LED indicators are located on the front of the MemoCam unit as shown in Figure 13 and described in Table 2.

Figure 13. LED Indicators

Page 25: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

19

Table 2. LED Indications

LED Color Description

Left

(Multimedia Card Status)

Red Multimedia card is faulty or not inserted correctly

Blinking Green

Data is being written to the Multimedia card

Orange Multimedia card is full

Middle

(PIR Activation)

Flashing Red

Movement detected

(Power Indication for DVR) Red Power is connected.

Right

(Arm Mode)

Orange

None

ARM mode

DISARM mode

Audible Signals (Beeps) The MemoCam unit can be configured to emit an audible signal (beep) when you use the remote control to:

Arm the unit – Long beep.

Enter a disarm code – Short beep after each button is pressed.

Disarm the unit – Two short beeps and one long beep.

The MemoCam unit can also emit an audible signal when:

In Disarm mode.

The Multimedia card is not inserted.

When configuration returns to the factory default.

Audible signals can be configured according to the procedures in the MemoCam Software Manual.

Page 26: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation
Page 27: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

21

USING THE REMOTE CONTROL

The Remote Control Unit provided with your MemoCam is used to Arm, Disarm, and manually record image snapshots. It can also be used to control the image displayed on a connected video monitor for MemoCam Plus and DVR.

Figure 14. The MemoCam Remote Control Unit

The remote control unit has the following buttons:

Rec – Triggers a snapshot to be taken.

Arm – Activates the MemoCam for operation.

Disarm – Deactivates the MemoCam.

Function – Not in use.

Four digit buttons numbered 1, 2, 3, 4 – Allows for Disarm Code entry. Selects from multiple cameras in MemoCam Plus and MemoCam DVR only.

Page 28: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

22

Insert batteries into the Remote Control unit before use.

Arming the MemoCam To activate (arm) the MemoCam:

1. Make sure the MemoCam unit is plugged in, and the Multimedia card is inserted.

2. Point the Remote Control unit at the MemoCam and press the Arm button. The MemoCam unit beeps once and the Arm Mode (right) LED illuminates orange to inform you that the unit is armed.

An exit delay allows you several seconds to exit the room before the MemoCam detector arms the system.

You can also automatically arm the MemoCam unit upon Multimedia card insertion, or schedule MemoCam to arm itself at particular times. Refer to the MemoCam Software Manual for details.

Disarming the MemoCam To de-activate (disarm) the MemoCam:

1. Point the Remote Control unit at the MemoCam and enter the Disarm Code using the four digit buttons. To define a Disarm Code, refer to the MemoCam Software Manual.

2. Press the Disarm button. The MemoCam unit beeps three times and the Arm Mode (right) LED turns off to inform you that the unit is disarmed.

You have a few seconds to enter the room before the MemoCam detector records an image in the system. Refer to the MemoCam Software Manual for information on how to define the Entry Delay.

Page 29: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

23

Manual Image Recording – Snapshot To manually record an image:

1. Make sure that the MemoCam is in disarm mode, and the Multimedia card is inserted.

2. Point the Remote Control unit at the MemoCam and press the Rec button. The Multimedia Card Status (left) LED blinks green informing you that an image is being recorded.

The Snapshot function should also be used to check the MemoCam after initial installation.

In MemoCam Plus and DVR, all connected cameras record snapshots according to the configuration programmed with the software.

Using the Video Output This function is available in MemoCam Plus and MemoCam DVR only when the unit is in Disarm mode.

The Video Output function can be used for fine adjustment of the MemoCam unit’s position while in disarm mode, and for live video monitoring.

Use the numbered buttons on the remote control unit to select which camera’s image is displayed on the video monitor as follows:

Button 1 – Displays the image from Camera 1.

Button 2 – Displays the image from Camera 2.

Button 3 – Displays the image from Camera 3.

Button 4 – Cycles the image between all selected cameras.

Refer to the MemoCam Software Manual for details.

Page 30: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation
Page 31: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

25

TROUBLESHOOTING

Use the following table to troubleshoot your MemoCam. Should you require further assistance or support in using your MemoCam, you can visit the support section of our web site at www.vdomain.com and file a problem report, or contact the local Video Domain representative.

Problem Symptom Solution

Unit does not work.

Impossible to operate unit, left LED does not glow, and PIR LED does not blink.

Check power supply and power cable.

The MemoCam unit does not record even though a Multimedia card is inserted in the unit.

Left red LED remains illuminated when Multimedia card is inserted into the unit. The unit does not recognize the Multimedia card.

1. Remove the Multimedia card from MemoCam unit.

2. Re-power the MemoCam unit.

3. Insert the card back into the MemoCam unit. After a few seconds, the left red LED should go off.

4. ARM the unit and make sure the left LED flashes GREEN when new images are recorded on the MMC.

Remote control does not work.

Unit does not arm and other remote control functions do not work. No beeping.

Check remote control batteries.

Cannot arm unit using remote control.

Unit may already be armed. Try to disarm the unit first.

Page 32: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

26

Problem Symptom Solution

Cannot disarm unit using remote control.

Unit may be already be disarmed, or you may not be disarming the unit properly. You must enter the disarm code and the click the disarm button. Check that the code is correct.

Image recording using the remote control does not function.

Ensure unit is disarmed – You cannot use snapshot recording when system is armed.

MemoCam application does not correctly read the Multimedia card.

You have error messages.

Check that Multimedia card is inserted correctly into reader. Try restarting MemoCam application.

MemoCam application does not start correctly.

Check that you installed the application as described in the manual. If not, reinstall the application.

You have error messages while working with MemoCam application.

Restart application.

Reader is not installed as additional drive.

You see the Multimedia card as A: or B: drive. MemoCam Application works in demo mode.

Edit the memocam.ini file to force the reader drive as follows: [Source] MMC-Source=a:\

Page 33: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

27

TECHNICAL SPECIFICATIONS

Following are the specifications for the various MemoCam systems.

Dimensions External dimensions W x H x D (excluding base)

67 x 135 x 56 mm

Weight (excluding base) 250 g

Camera For MemoCam and MemoCam Plus only.

TV standard B&W CCIR or EIA

Resolution 420 TV lines

Sensitivity 0.1 Lux (F2.0)

S/N Ratio Better than 48db

Shutter control Automatic 1/50 - 1/100,000

Pinhole lens F4.3 mm standard

Page 34: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

28

Multimedia Card Image Capacity (number of images)

Card Size High Quality: 20 KB per frame

Medium Quality: 10 KB per frame

Lowest Quality: 5 KB per frame

8 MB 350 700 1400

16 MB 750 1500 3000

32 MB 1500 3000 6000

64 MB 3000 6000 12000

128 MB 6000 12000 24000

Multimedia Card Reader Picture format JPEG with automatic Thumbnails

Support.

Picture quality options Good, Great, Better, and Best modes, from 5K up to 20K image sizes.

Recording rates From 3 images per second to 1 image per 5 minutes.

Recording options Fixed – Records fixed number of events until memory is full. Cyclic – Continues recording from start when Multimedia card is full.

Delay time between alarm triggers 1 sec to 999 sec

Number of images per event 1 to 101 images

Page 35: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

29

Infrared Motion Detector – Dual Element PIR For MemoCam and MemoCam Plus only.

Lens Type Hard Spherical Lens

Sensitivity 1.6 oC ( 3oF)@0.6 m/sec (2 ft/sec)

Detection Speed 0.3-1.5 m/sec (1-5 ft/sec)

Temp. compens. Bi-directional

Pulse count 1,2 Dipswitch; 2-3 Automatic depending on speed spectrum analysis.

Coverage Wide angle 90º 18m x 18m (60ft x 60ft)

RFI Protection 30V/m 10-1000 MHz

EMI Protection 50,000V of electric interference from lightning or power through.

Terminal Connectors and Switches External input Isolated dry contact input

Relay output 1) 28VDC, 0.1A with 10 ohm serial resistor, opens for 1.8 sec upon detection. Normally Closed

2) Control relay – Normally Open

Tamper switch If cover is removed.

Separated power feeds Optional Separated power feeds for PIR and Recording module sections.

Power Supply Total power consumption Maximum – 500 mA @ 12 VDC

PIR detector only Typical – 30 mA @ 12 VDC

MemoCam DVR Typical – 400 mA @ 12 VDC

Page 36: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

30

APPENDIX FOR MEMOCAM PLUS/S

The MemoCam Plus/S allows for serial communication. The Plus/S can be connected, together with additional Plus/S units, to a PC.

RS-485 ID Settings The MemoCam Plus/S unit has a built-in RS485 serial port (optional RS-232).

You must allocate a different RS-485 address for each MemoCam Plus/S unit installed on a parallel RS-485 line.

The RS-485 address range is 0-31. You can install up to 32 MemoCam Plus/S units on the same line. On the MemoCam Plus/S board, there are 5 dipswitches to define the RS-485 unit.

The following picture displays a view of the dipswitch board.

Figure 15. Dipswitch Board

Do not change the position of dipswitches 6 and 7. They should always be in the down position.

Page 37: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

31

The following table describes the dipswitch settings and the corresponding RS-485 unit ID number assigned.

RS-485 unit ID number

RS-485 Dip Switch Settings

RS-485 unit ID number

RS-485 Dip Switch Settings

0 Factory Default

16

1

17

2

18

3

19

4

20

5

21

6

22

7

23

8

24

9

25

Page 38: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

32

10

26

11

27

12

28

13

29

14

30

15

31

Page 39: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

33

Termination Dipswitch Dipswitch #8 is assigned for termination. If more than one unit is installed on the same line, dipswitch #8 should be in the up position in the last unit. In all other units, dipswitch #8 should be in the down position. For a single unit installed on the line, dipswitch #8 should be in the up position.

Figure 16. Termination Dipswitch

Wiring RS-485 The Host device or each COM port on your PC must be connected to the MemoCam Plus/S unit’s RS-485 terminal connector with four-wire cable in a daisy chain configuration.

The following picture shows possible connections of 3 MemoCam Plus/S units to a host device.

Figure 17. Connecting to Host

Page 40: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

34

Host Device Host RS-485 connection (or RS-485 converter) to your PC must be configured with following parameters:

RS-485 full duplex.

RS-485 master.

No flow control.

Wiring RS-232 The MemoCam Plus/S units can also be factory supplied for RS-232 connection.

When working with MemoCam Plus/S units with RS-232, you can only connect one unit.

The following picture shows the connections for RS-232.

Figure 18. RS-232 Connections

Page 41: MemoCam Installation Manual - Absolute Automation ...knowledgebase.absoluteautomation.com/documents/usr/memocam/... · Multimedia card following an alarm trigger. ... MemoCam Installation

35

GLOSSARY

Arm Enables of the automatic detection and recording function.

Cyclic Recording Continuous recording. The MemoCam records over older images from start of the cycle when Multimedia card is full.

Disarm Disables the automatic detection and recording function.

Entry Delay Time between first trigger and actual recording (unit is armed)

Entry delay can be used when entering a room to avoid event recording until the unit is disarmed.

Event The recording of one or more images as a result of a trigger.

Exit Delay Once the operator arms the unit, a delay can be used to avoid event recording when exiting the room.

LED Light Emitting Diode

Multimedia card A stamp-sized plastic card containing read/write non-volatile memory.

PIR Passive Infrared motion detector.

Snapshot Recording of a single picture.

Trigger A signal that activates the recording process. Usually generated by an alarm contact.

VMD Video Motion Detection. A feature that detects changes in video frames.