2
Quick Hardware Installation Guide English MAN-BBU-QH 02-20-03 MegaRAC™ G2 Battery Backup Unit (for Series 827) Thank you for purchasing the MegaRAC™ G2 Battery Backup Unit. Please take a few minutes to review this quick guide before beginning the installation process. Contents for the MegaRAC™ G2 Battery Backup Unit You should have received the following: one MegaRAC™ G2 Battery Backup Unit (BAT-LIION-3.6-01) one battery clip this MegaRAC™ G2 Optional Battery Quick Installation Guide Technical Support If you need help installing or configuring the MegaRAC G2 Battery Backup Unit, call American Megatrends technical support at 770- 246-8645. Technical Support Web Site: http://www.ami.com/support/ Technical Support Email: [email protected] Hardware Installation Following the steps in this guide to install the MegaRAC G2 Battery Backup Unit. Note: Inspect the cardboard carton for obvious damage. If damaged, call 770-246-8645. Leave the MegaRAC G2 Battery Backup Unit in its original packing. Unpack the MegaRAC G2 Battery Backup Unit and Battery Clip Inspect the cardboard carton for obvious damage. If damaged, call 770-246-8600. Leave it in its original packing. Perform all unpacking and installation procedures on a ground-connected anti-static mat. The MegaRAC G2 battery backup unit is an optional component. When the optional battery is installed, your MegaRAC G2 card can stay powered on for 30 minutes without any external power from the host system or AC adapter. To install the Battery Backup Unit, plug the battery cable into the J1 connector and place the battery pack in between the three mounting holes. Next, align and snap the plastic battery clip into the three mounting holes over the battery pack. See the diagram on the right. Charging the Battery Backup Unit WARNING! Risk of explosion if battery type used is incorrect. ONLY use American Megatrends battery part number BAT- LIION-3.6-01. The Battery Backup Unit is shipped uncharged. The MegaRAC G2 card automatically starts to charge the battery after you install it. You must charge the battery pack before it can be used to provide backup power to the MegaRAC G2 card. Diagram Align and snap the battery clip into the three mounting holes on top side of the PCB over the battery backup unit Place the battery in between the three mouniting holes Plug the battery cable into the J1 connector

MegaRAC™ G2 Battery Backup Unit · 2014-11-18 · Quick Hardware Installation Guide English Charging the Battery Backup Unit, Continued The minimum time that the battery must be

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MegaRAC™ G2 Battery Backup Unit · 2014-11-18 · Quick Hardware Installation Guide English Charging the Battery Backup Unit, Continued The minimum time that the battery must be

Quick Hardware Installation Guide EnglishMAN-BBU-QH

02-20-03

MegaRAC™ G2Battery Backup Unit

(for Series 827)

Thank you for purchasing the MegaRAC™ G2 Battery Backup Unit.Please take a few minutes to review this quick guide before beginningthe installation process.

Contents for the MegaRAC™ G2 Battery BackupUnit

You should have received the following:

• one MegaRAC™ G2 Battery Backup Unit (BAT-LIION-3.6-01)• one battery clip• this MegaRAC™ G2 Optional Battery Quick Installation Guide

Technical Support

If you need help installing or configuring the MegaRAC G2 BatteryBackup Unit, call American Megatrends technical support at 770-246-8645.

Technical Support Web Site: http://www.ami.com/support/Technical Support Email: [email protected]

Hardware Installation

Following the steps in this guide to install the MegaRAC G2 BatteryBackup Unit.

Note: Inspect the cardboard carton for obvious damage. Ifdamaged, call 770-246-8645. Leave the MegaRAC G2 BatteryBackup Unit in its original packing.

Unpack the MegaRAC G2 Battery Backup Unitand Battery Clip

Inspect the cardboard carton for obvious damage. If damaged, call770-246-8600. Leave it in its original packing. Perform all unpackingand installation procedures on a ground-connected anti-static mat.

The MegaRAC G2 battery backup unit is an optional component.When the optional battery is installed, your MegaRAC G2 card canstay powered on for 30 minutes without any external power from thehost system or AC adapter.

To install the Battery Backup Unit, plug the battery cable into the J1connector and place the battery pack in between the three mountingholes. Next, align and snap the plastic battery clip into the threemounting holes over the battery pack. See the diagram on the right.

Charging the Battery Backup Unit

WARNING!

Risk of explosion if battery type used is incorrect.ONLY use American Megatrends battery part number BAT-

LIION-3.6-01.

The Battery Backup Unit is shipped uncharged. The MegaRAC G2card automatically starts to charge the battery after you install it. Youmust charge the battery pack before it can be used to provide backuppower to the MegaRAC G2 card.

Diagram

Align and snap the battery clip into the threemounting holes on top side of the PCB over thebattery backup unit

Place the batteryin between the three mouniting holes

Plug the battery cableinto the J1 connector

Page 2: MegaRAC™ G2 Battery Backup Unit · 2014-11-18 · Quick Hardware Installation Guide English Charging the Battery Backup Unit, Continued The minimum time that the battery must be

Quick Hardware Installation Guide EnglishCharging the Battery Backup Unit, Continued

The minimum time that the battery must be charged is:

AMI Part Number Description Weight TimetoCharge

Changing the Battery Backup Unit

The optional MegaRAC G2 Battery Backup Unit must be replacedevery 400 cycles. Cells retain 80% of their original capacity after 400cycles. A cycle is defined as a full charge (4.2V) followed by a fulldischarge (2.8V). Keep in mind that cycling or storing the cells atelevated temperatures can reduce the cell capacity and cycle life.Cells discharged and stored at low temperatures can extend the shelflife of the batteries.

BAT-LIION-3.6-01 Battery, Li-Ion, 3.6 V,855/900 mAh on-boardbattery pack withmounting brackets

33 g sixhours

Step Action1 Bring down the operating system properly. Turn the

computer power off. Remove the computer cover. Removethe MegaRAC G2 card.

2 Disconnect the battery pack cable from the J1 jumper on theMegaRAC G2 card. Remove the plastic battery clip andthen replace the Battery Backup Unit.

3 Install a new battery pack and connect the new battery packto the J1 jumper.

4 Reinstall the MegaRAC G2 card into the host system.

Note: Li-Ion has no memory effect. Lithium-ion cells offerextended cycle life when cycled at low depth of discharge.

Storage

If you keep a stock of extra MegaRAC G2 batteries, store them atroom temperature.

Note: The recoverable capacity of cells stored for over one year atroom temperature and fully charged is 94%. The retained capacity ofthese same cells is 87%. This means the self-discharge rate for a fullycharged cell is approximately 150 mAh per year or 427 uAh per day.The self-discharge rate for cells is non-linear. A partially charged cellhas a self-discharge rate of about 80 uAh per day.

Disposing of a Battery Pack Battery Disposal Laws

WARNING!

Do not dispose of the MegaRAC G2 Battery Backup Unit byfire. Do not mutilate the battery pack. Do not damage it in anyway. Toxic chemicals can be released if it is damaged. Do not

short-circuit the battery pack.

IMPORTANT!

Most used Lithium-ion batteries are not classified ashazardous waste under the federal RCRA (Resource

Conservation and Recovery Act). Although Minnesota lawrequires that Lithium-ion batteries be labeled “easily

removable” from consumer products, and that Lithium-ionbatteries must be collected by manufacturers, the

Minnesota Pollution Control Agency (MPCA) has granteda temporary exemption from these requirements.

The material in the battery pack contains heavy metals that cancontaminate the environment. Federal, state, and local laws prohibitdisposal of some rechargeable batteries in public landfills. Thesebatteries must be sent to a specific location for proper disposal. Callthe Rechargeable Battery Recycling Corporation at 678-419-9990(FAX: 678-419-9986) for an authorized battery disposal site near you.For a list of battery disposal sites, write to:

Rechargeable Battery Recycling Corporationhttp://www.rbrc.org/1000 Parkwood CircleSuite 450Atlanta, GA 30339Phone: 678-419-9990Fax: 678-419-9986

Other Laws in Other Areas

American Megatrends reminds you that you must comply with allapplicable battery disposal and hazardous material handling laws andregulations in the country or other jurisdiction where you are using anBattery Backup Unit on the MegaRAC G2 card.

AMI Corporate HeadquartersAmerican Megatrends Inc.5555 Oakbrook Parkway, Building 200,Norcross, Georgia 30093Sales (800)828-9264 [email protected] (770)246-8600 Fax (770)246-8790 All trademarks & trade names used in this document refer to either the entities claiming the marks & names or their products. AMI disclaims any proprietary interest in trademarks & trade names other than its own. ©1985-2010 American Megatrends Inc. All Rights Reserved.

www.ami.com