Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
1199
VIL
LAG
E R
OA
DC
AR
BO
ND
ALE
, CO
. 816
23
ME
DIC
AL
OFF
ICE
BU
ILD
ING
INTE
RN
ATI
ON
AL
BU
ILD
ING
CO
DE
(IB
C 2
009)
IN
TER
NA
TIO
NA
L P
LUM
BIN
G C
OD
E (I
PC
200
9)
IBC
GR
OU
P B
IBC
TY
PE
V-B
- A
NY
CO
NS
TRU
CTI
ON
PE
RM
ITTE
D B
Y IB
C
BU
ILD
ING
CO
DE
S:
OC
CU
PA
NC
Y:
CO
NS
TRU
CTI
ON
TY
PE
:
SP
RIN
KLE
R S
YS
TEM
:
NFP
A 7
2 - N
ATI
ON
AL
FIR
E A
LAR
M C
OD
EN
FPA
70
- NA
TIO
NA
L E
LEC
TRIC
AL
CO
DE
(NE
C 2
014)
INTE
RN
ATI
ON
AL
ME
CH
AN
ICA
L C
OD
E (I
MC
200
9)
NFP
A 1
3 - I
NS
TALL
ATI
ON
OF
FIR
E S
PR
INK
LER
SY
STE
MS
ALL
OW
ED
:P
RO
VID
ED
:
BU
ILD
ING
AR
EA
:
ICC
/AN
SI A
117.
1-20
03 A
CC
ES
SIB
LE &
US
AB
LE B
UIL
DIN
GS
AM
ER
ICA
NS
WIT
H D
ISA
BIL
ITIE
S A
CT
(AD
A)
INTE
RN
ATI
ON
AL
FUE
L G
AS
CO
DE
(IFG
C 2
009)
IN
TER
NA
TIO
NA
L E
NE
RG
Y C
ON
SE
RV
ATI
ON
CO
DE
(IE
CC
200
9)
INTE
RN
ATI
ON
AL
FIR
E C
OD
E (I
FC 2
009)
IBC
TA
BLE
503
ALL
OW
S 9
,000
SQ
UA
RE
FE
ET
TAB
ULA
R B
AS
E A
RE
AFO
R B
OC
CU
PA
NC
Y.
BU
ILD
ING
AR
EA
MO
DIF
ICA
TIO
NS
PE
RM
ITTE
DB
Y IB
C S
EC
TIO
N 5
06 A
RE
AP
PLI
CA
BLE
: AU
TOM
ATI
C F
IRE
SP
RIN
KLE
R:
200%
AR
EA
INC
RE
AS
E A
LLO
WE
DFR
ON
TAG
E IN
CR
EA
SE
:
47.9
% A
RE
A IN
CR
EA
SE
ALL
OW
ED
TOTA
L A
LLO
WED
AR
EA W
ITH
INC
REA
SES
= 31
,311
SF
THE
BU
ILD
ING
S W
ILL
BE
FU
LLY
PR
OTE
CTE
D B
Y A
NA
UTO
MA
TIC
FIR
E S
PR
INK
LER
SY
STE
M M
EE
TIN
G N
FPA
13.
NO
T R
EQ
UIR
ED
BY
IBC
FO
R B
OC
CU
PA
NC
Y.
PO
RTA
BLE
FIR
E E
XTI
NG
UIS
HE
RS
:TH
E B
UIL
DIN
G W
ILL
BE
EQ
UIP
PE
D W
ITH
PO
RTA
BLE
FIR
EE
XTI
NG
UIS
HE
RS
ME
ETI
NG
NFP
A 1
0.R
EQ
UIR
ED
BY
IBC
906
.1 F
OR
GR
OU
P B
FIR
E A
LAR
M S
YS
TEM
:A
UTO
MA
TIC
FIR
E A
LAR
M S
YS
TEM
WIT
H O
CC
UP
AN
TN
OTI
FIC
ATI
ON
SY
STE
M P
RO
VID
ED
(NO
MA
NU
AL
FIR
EA
LAR
M B
OX
ES
) & C
ON
NE
CTE
D T
O F
IRE
SP
RIN
KLE
RS
YS
TEM
PE
R N
FPA
72
IBC
SE
CTI
ON
907
.2.2
- E
XC
EP
TIO
N: M
AN
UA
L FI
RE
ALA
RM
ISN
OT
RE
QU
IRE
D F
OR
A B
UIL
DIN
G E
QU
IPP
ED
WIT
H A
FIR
ES
PR
INK
LER
SY
STE
M F
OR
B O
CC
UP
AN
CY
.
BU
ILD
ING
HE
IGH
T:2
STO
RY
PR
OV
IDE
D.
CU
RR
EN
T B
UIL
DIN
G H
EIG
HT
IS31
'-6" F
RO
M G
RA
DE
TO
HIG
HE
ST
PO
RTI
ON
OF
THE
ELE
VA
TOR
TO
WE
R R
OO
F.
IBC
TA
BLE
503
ALL
OW
S 2
STO
RY
AN
D 4
0 FE
ET
PLU
S A
NIN
CR
EA
SE
OF
1 S
TOR
Y A
ND
20
FEE
T P
ER
IBC
504
.2 F
OR
AB
UIL
DIN
G E
QU
IPP
ED
WIT
H A
N A
UTO
MA
TIC
FIR
E S
PR
INK
LER
SY
STE
M.
RO
OF
STR
UC
TUR
ES
:R
OO
F LI
NE
IS L
ES
S T
HA
N 2
0 FE
ET
AB
OV
E A
LLO
WA
BLE
BU
ILD
ING
HE
IGH
T.IB
C 5
04.3
PE
RM
ITS
CO
MB
US
TIB
LE R
OO
F S
TRU
CTU
RE
SH
EIG
HTS
OF
UP
TO
20
FEE
T A
BO
VE
ALL
OW
AB
LE B
UIL
DIN
GH
EIG
HT.
TYP
E O
F C
ON
STR
UC
TIO
N:
TYP
E V
-B
IB
C T
AB
LE 6
01 N
O F
IRE
-RE
SIS
TAN
T R
ATI
NG
RE
QU
IRE
D F
OR
BU
ILD
ING
ELE
ME
NTS
.
EX
TER
IOR
WA
LLS
DO
NO
T H
AV
E T
O B
E F
IRE
-RA
TED
IBC
TA
BLE
602
:W
ES
T W
ALL
: X
>30
NO
RA
TIN
G R
EQ
UIR
ED
EA
ST
WA
LL:
10<X
<30
NO
RA
TIN
G R
EQ
UIR
ED
NO
RTH
WA
LL: X
>30
NO
RA
TIN
G R
EQ
UIR
ED
SO
UTH
WA
LL: X
>30
NO
RA
TIN
G R
EQ
UIR
ED
EX
TER
IOR
WA
LL F
IRE
-RE
SIS
TAN
TR
ATI
NG
BA
SE
D O
N F
IRE
SE
PA
RA
TIO
ND
ISTA
NC
E:
IBC
SE
CTI
ON
705
.8 E
XC
EP
TIO
N 2
. BU
ILD
ING
S W
HO
SE
EX
TER
IOR
BE
AR
ING
WA
LLS
, EX
TER
IOR
NO
NB
EA
RIN
GW
ALL
S A
ND
EX
TER
IOR
PR
IMA
RY
STR
UC
TUR
AL
FRA
ME
AR
E N
OT
RE
QU
IRE
D T
O B
E F
IRE
-RE
SIS
TAN
CE
RA
TED
SH
ALL
BE
PE
RM
ITTE
D T
O H
AV
E U
NLI
MIT
ED
UN
PR
OTE
CTE
D O
PE
NIN
GS
.
IBC
TA
BLE
705
.8 F
OR
UN
PR
OTE
CTE
D O
PE
NIN
GS
IN A
FU
LLY
SP
RIN
KLE
RE
D B
UIL
DIN
G:
WE
ST
WA
LL:
30
OR
GR
EA
TER
: NO
LIM
ITS
PO
RTI
ON
OF
EA
ST
WA
LL:
10
TO L
ES
S T
HA
N 1
5: 4
5%N
OR
TH W
ALL
: 30
OR
GR
EA
TER
: NO
LIM
ITS
SO
UTH
WA
LL: 3
0 O
R G
RE
ATE
R: N
O L
IMIT
S
MA
XIM
UM
OP
EN
ING
S IN
EX
TER
IOR
WA
LLS
BA
SE
D O
N F
IRE
SE
PA
RA
TIO
ND
ISTA
NC
E:
FIN
ISH
ES
TH
RO
UG
HO
UT
SH
ALL
BE
MIN
. CLA
SS
C E
XC
EP
T IN
EX
IT E
NC
LOS
UR
ES
& E
XIT
PA
SS
AG
EW
AY
S W
HIC
H S
HA
LL B
EM
IN. C
LAS
S B
PE
R IB
C T
AB
LE 8
03.9
INTE
RIO
R F
INIS
HE
S:
EG
RE
SS
WID
TH:
OC
CU
PA
NT
LOA
D O
N F
IRS
T FL
OO
R IS
:O
CC
UP
AN
T LO
AD
ON
SE
CO
ND
FLO
OR
IS:
IBC
100
5.1
THE
ME
AN
S O
F E
GR
ES
S W
IDTH
SH
ALL
NO
T B
E L
ES
STH
AN
TH
E O
CC
UP
AN
T LO
AD
SE
RV
ED
BY
TH
E M
EA
NS
OF
EG
RE
SS
TIM
ES
0.2
" (0.
3" F
OR
STA
IRW
AY
S)
AC
CE
SS
IBLE
ME
AN
S O
F E
GR
ES
S:
IBC
100
7.1
ON
E A
CC
ES
SIB
LE M
EA
NS
OF
EG
RE
SS
IS R
EQ
UIR
ED
IN N
EW
BU
ILD
ING
S W
HE
RE
ON
LY O
NE
ME
AN
S O
F E
GR
ES
S IS
RE
QU
IRE
D.
IBC
101
4.3
- E
XC
EP
TIO
N 1
. 100
FE
ET
FOR
GR
OU
P B
EQ
UIP
PE
DW
ITH
AN
AU
TOM
ATI
C S
PR
INK
LER
SY
STE
M.
CO
MM
ON
PA
TH O
F E
GR
ES
STR
AV
EL:
IBC
TA
BLE
101
5.1
ON
E E
XIT
OR
EX
IT A
CC
ES
S D
OO
RW
AY
IS A
LLO
WE
D F
RO
M B
OC
CU
PA
NC
Y W
HE
N T
HE
IR O
CC
UP
AN
T LO
AD
IS 4
9 O
R L
ES
S.
NU
MB
ER
OF
EX
ITS
:
IBC
TA
BLE
101
6.1
- FO
R B
UIL
DIN
G W
ITH
SP
RIN
KLE
R:
300
FEE
T A
LLO
WE
D F
RO
M B
OC
CU
PA
NC
IES
EX
IT A
CC
ES
S T
RA
VE
L D
ISTA
NC
E:
IBC
TA
BLE
101
8.2
- N
OT
LES
S T
HA
N 4
4" O
R E
XC
EP
TIO
N 2
- 36
"W
HE
N S
ER
VIN
G L
ES
S T
HA
N 5
0 O
CC
UP
AN
TS.
MIN
IMU
M C
OR
RID
OR
WID
TH:
PE
R T
AB
LE 5
08.4
NO
SE
PA
RA
TIO
N IS
RE
QU
IRE
DB
ETW
EE
N B
OC
CU
PA
NC
IES
.G
RO
UP
B -
BU
SIN
ES
S A
ND
OU
TPA
TIE
NT
CLI
NIC
WH
ER
EP
ATI
EN
TS A
RE
NO
T R
EN
DE
RE
D IN
CA
PA
BLE
OF
SE
LFP
RE
SE
RV
ATI
ON
BY
TH
E S
ER
VIC
ES
PR
OV
IDE
D.
OC
CU
PA
NC
Y G
RO
UP
:
CO
RR
IDO
R F
IRE
RE
SIS
TAN
CE
RA
TIN
G N
OT
RE
QU
IRE
D W
ITH
FIR
E S
PR
INK
LER
SY
STE
M F
OR
B O
CC
UP
AN
CIE
S P
ER
IBC
TAB
LE 1
018.
1
CO
RR
IDO
R F
IRE
RE
SIS
TAN
CE
:
EX
ISTI
NG
GR
OS
S B
UIL
DIN
G A
RE
A F
OR
BU
ILD
ING
IS10
,703
S.F
.
INTE
RN
ATI
ON
AL
GR
EE
N C
ON
STR
UC
TIO
N C
OD
E (I
GC
C 2
012)
WIT
H T
OW
N O
F C
AR
BO
ND
ALE
AM
EN
DM
EN
TS
10,7
03 S
F TO
TAL
GR
OS
S B
UIL
DIN
G A
RE
AB
UIL
DIN
G A
RE
A:
THE
OC
CU
PA
NT
LOA
D O
F E
AC
H F
LOO
R IS
LE
SS
TH
AN
49
AN
D O
NE
ME
AN
S O
F E
GR
ES
S IS
RE
QU
IRE
D. O
NE
AC
CE
SS
IBLE
ME
AN
S O
F E
GR
ES
S IS
PR
OV
IDE
D.
IBC
708
.4 F
IRE
RE
SIS
TAN
CE
RA
TIN
G O
F S
HA
FTS
SH
ALL
BE
1H
OU
R W
HE
RE
CO
NN
EC
TIN
G L
ES
S T
HA
N F
OU
R S
TOR
IES
.
IBC
708
.1 E
XC
EP
TIO
N 1
1: A
SH
AFT
EN
CLO
SU
RE
IS N
OT
RE
QU
IRE
D F
OR
FLO
OR
OP
EN
ING
S C
RE
ATE
D B
Y U
NE
NC
LOS
ED
STA
IRS
IN A
CC
OR
DA
NC
E W
ITH
EX
CE
PTI
ON
3 O
R 4
IN S
EC
TIO
N10
16.1
IBC
708
.14.
1 E
XC
EP
TIO
N 4
: EN
CLO
SE
D E
LEV
ATO
R L
OB
BIE
SA
RE
NO
T R
EQ
UIR
ED
WH
ER
E T
HE
BU
ILD
ING
IS E
QU
IPP
ED
BY
AN
AU
TOM
ATI
C S
PR
INK
LER
SY
STE
M P
ER
NFP
A 1
3.
SH
AFT
EN
CLO
SU
RE
:
IBC
101
6.1
EX
CE
PTI
ON
3: 5
0% O
F E
XIT
S IS
PE
RM
ITTE
DTH
RO
UG
H U
NE
NC
LOS
ED
EX
IT A
CC
ES
S S
TAIR
WA
Y W
HE
NC
ON
NE
CTI
NG
A M
AX
IMU
M O
F TW
O S
TOR
IES
.
EX
IT T
HR
OU
GH
OP
EN
LO
BB
Y:
2 E
XIT
S A
RE
PR
OV
IDE
D F
RO
M E
AC
H F
LOO
R S
INC
E T
HE
UN
EN
CLO
SE
D E
XIT
AC
CE
SS
STA
IRW
AY
IS U
SE
D IN
TH
ELO
BB
Y P
ER
101
6.1
EX
CE
PTI
ON
3.
2 E
XIT
S A
RE
PR
OV
IDE
D
IBC
102
2.1
STA
IRW
AY
CO
NN
EC
TIN
G L
ES
S T
HA
N F
OU
RS
TOR
IES
SH
ALL
HA
VE
AN
EX
IT E
NC
LOS
UR
E O
F N
OT
LES
STH
AN
1 H
OU
R R
ATI
NG
.
INTE
RIO
R E
XIT
STA
IRW
AY
:TH
E S
EC
ON
D R
EA
R E
XIT
STA
IRW
AY
IS E
NC
LOS
ED
IN A
1 H
R R
ATE
D E
NC
LOS
UR
E.
THE
ELE
VA
TOR
SH
AFT
AN
D R
EA
R E
XIT
STA
IR A
RE
EN
CLO
SE
D W
ITH
A 1
HR
RA
TED
EN
CLO
SU
RE
.
THE
LO
BB
Y S
TAIR
IS E
XE
MP
T FR
OM
BE
ING
EN
CLO
SE
D IN
A F
IRE
RA
TED
EN
CLO
SU
RE
.
THE
LO
BB
Y IS
EX
EM
PT
FRO
M B
EIN
G E
NC
LOS
ED
IN A
FIR
E R
ATE
D E
NC
LOS
UR
E.
CO
RR
IDO
RS
PR
OV
IDE
D A
RE
NO
T LE
SS
TH
AN
44"
OC
CU
PA
NT
LOA
D:
IBC
TA
BLE
100
4.1.
1 B
US
INE
SS
AR
EA
100
SF/
OC
CU
PA
NT
AC
CE
SS
OR
Y,S
TOR
AG
E&
ME
CH
. RO
OM
S 3
00S
F/O
CC
UP
AN
TO
CC
UP
AN
T LO
AD
CA
LCU
LATI
ON
:1S
T FL
OO
R O
FFIC
E S
PA
CE
: 4,7
78 /
100
= 48
OC
CU
PA
NTS
1ST
FLO
OR
AC
CE
SS
OR
Y S
PA
CE
: 693
/ 30
0 =
3 O
CC
UP
AN
TS2N
D F
LOO
R O
FFIC
E S
PA
CE
: 4,0
12 /
100
= 41
OC
CU
PA
NTS
2ND
FLO
OR
AC
CE
SS
OR
Y S
PA
CE
: 1,1
21 /
300
= 4
OC
CU
PA
NTS
TOTA
L B
UIL
DIN
G O
CC
UP
AN
T LO
AD
: 96
OC
CU
PA
NTS
A O
NE
HO
UR
RA
TED
SE
PA
RA
TIO
N IS
PR
OV
IDE
DB
ETW
EE
N T
HE
FIR
ST
AN
D S
EC
ON
D F
LOO
RS
AN
D A
T TH
EP
ER
IME
TER
OF
SU
ITE
#4
ON
TH
E S
EC
ON
D F
LOO
R.
IBC
101
8.4
EX
CE
PTI
ON
#4
- IN
GR
OU
P B
WIT
H A
N A
UTO
MA
TIC
SP
RIN
KLE
R S
YS
TEM
TH
E L
EN
GTH
OF
THE
DE
AD
EN
DC
OR
RID
OR
SH
ALL
NO
T E
XC
EE
D 5
0 FE
ET.
DE
AD
EN
DS
:N
O D
EA
D E
ND
CO
RR
IDO
R E
XC
EE
DS
50
FEE
T.
THES
E PL
ANS
ARE
INST
RUM
ENTS
OF
PROF
ESSI
ONAL
SER
VICE
AND
ARE
PROT
ECTE
D BY
COM
MON
LAW
, STA
TUTO
RY A
NDOT
HER
RES
ERVE
D RI
GHTS
INCL
UDIN
G CO
PYRI
GHT.
TH
EY M
AYNO
T BE
REP
RODU
CED
OR U
SED
FOR
ANY
PURP
OSE
WIT
HOU
TTH
E W
RITT
EN C
ONSE
NT O
F TH
E DE
SIGN
PRO
FESS
IONA
L©20
14
PR
OJE
CT
SC
OP
E O
F W
OR
K
SIT
E S
AFE
TY N
OTE
S
WE
CE
RTI
FY T
HA
T TO
TH
E B
ES
T O
F O
UR
KN
OW
LED
GE
AN
D IN
FOR
MA
TIO
N, A
ND
IN A
CC
OR
DA
NC
E W
ITH
AC
CE
PTE
D P
RO
FES
SIO
NA
L S
TAN
DA
RD
S, W
E H
AV
E C
OM
PLI
ED
WIT
H A
PP
LIC
AB
LE G
OV
ER
NIN
G C
OD
ES
PE
RTA
ININ
G T
O B
UIL
DIN
G A
CC
ES
SIB
ILIT
Y F
OR
TH
E P
HY
SIC
ALL
Y H
AN
DIC
AP
PE
D A
ND
TH
E A
ME
RIC
AN
S W
ITH
DIS
AB
ILIT
IES
AC
T (A
DA
) TIT
LE II
I AC
CE
SS
IBIL
ITY
GU
IDE
LIN
ES
FO
R B
UIL
DIN
G A
ND
FA
CIL
ITIE
S.
IN T
HE
EV
EN
T O
F C
ON
FLIC
TS, E
XP
LAN
ATO
RY
NO
TES
IN T
HE
DR
AW
ING
S T
AK
E P
RE
CE
DE
NC
E O
VE
R G
RA
PH
ICIN
DIC
ATI
ON
S; L
AR
GE
-SC
ALE
DR
AW
ING
S A
ND
DE
TAIL
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
MA
LLE
R S
CA
LE D
RA
WIN
GS
,A
ND
FIG
UR
ED
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D D
IME
NS
ION
S.
IF A
ND
TO
TH
E E
XTE
NT
OF
AN
Y IN
CO
NS
ISTE
NC
Y, A
MB
IGU
ITY
, DIS
CR
EP
AN
CY
, OR
ER
RO
R IN
TH
E C
ON
TRA
CT
DO
CU
ME
NTS
(RE
FER
RE
D T
O A
S "D
ISC
RE
PA
NC
Y" C
OLL
EC
TIV
ELY
IN T
HIS
PA
RA
GR
AP
H),
THE
CO
NTR
AC
TOR
SH
ALL
IMM
ED
IATE
LY S
EE
K C
LAR
IFIC
ATI
ON
TH
RO
UG
H T
HE
CO
NS
TRU
CTI
ON
MA
NA
GE
R W
HO
MA
Y IN
TU
RN
SE
EK
CLA
RIF
ICA
TIO
N F
RO
M T
HE
AR
CH
ITE
CT.
IN
INTE
RP
RE
TIN
G T
HE
CO
NTR
AC
T D
OC
UM
EN
TS, A
LL T
ER
MS
AN
DC
ON
DIT
ION
S S
HA
LL B
E H
AR
MO
NIZ
ED
AN
D E
FFE
CTU
ATE
D, A
ND
NO
NE
SH
ALL
BE
RE
ND
ER
ED
SU
PE
RFL
UO
US
OR
ME
AN
ING
LES
S.
IN T
HE
EV
EN
T O
F A
DIS
CR
EP
AN
CY
TH
AT
CA
NN
OT
BE
HA
RM
ON
IZE
D, T
HE
INTE
RP
RE
TATI
ON
TH
AT
IMP
OS
ES
TH
E M
OS
T S
TRIN
GE
NT
PE
RFO
RM
AN
CE
OB
LIG
ATI
ON
ON
TH
E C
ON
TRA
CTO
R S
HA
LL C
ON
TRO
L.
ALL
DIM
EN
SIO
NS
ON
CO
RE
AN
D S
HE
LL D
RA
WIN
GS
AR
E T
O T
HE
EX
TER
IOR
FA
CE
OF
FOU
ND
ATI
ON
WA
LL O
RS
TRU
CTU
RA
L G
RID
LIN
ES
U.N
.O.
INS
TALL
SE
ALA
NT
AT
EX
TER
IOR
SID
E O
F A
LL J
OIN
TS, S
EA
MS
, CO
NN
EC
TIO
NS
OR
OP
EN
ING
S A
S W
ELL
AS
SID
EW
ALK
S A
BU
TTIN
G T
O B
UIL
DIN
G, W
HIC
H W
OU
LD A
LLO
W W
ATE
R O
R A
IR IN
FILT
RA
TIO
N E
XC
EP
T A
S N
OTE
DO
THE
RW
ISE
. SE
ALA
NT
CO
LOR
TO
MA
TCH
AD
JAC
EN
T S
UR
FAC
E.
DO
OR
OP
EN
ING
S IN
FR
AM
E C
ON
STR
UC
TIO
N W
HIC
H A
RE
NO
T D
IME
NS
ION
ED
AR
E E
ITH
ER
CE
NTE
RE
D IN
TH
EW
ALL
OR
LO
CA
TED
4" F
RO
M T
HE
FA
CE
OF
STU
D T
O T
HE
FIN
ISH
ED
JA
MB
ON
TH
E H
ING
ED
SID
E.
ALL
SP
EC
IAL
AC
CE
SS
IBLE
FA
CIL
ITIE
S S
HA
LL B
E ID
EN
TIFI
ED
WIT
H A
PP
RO
VE
D S
IGN
AG
E.
THE
CO
NTR
AC
TOR
IS R
ES
PO
NS
IBLE
FO
R P
RO
DU
CIN
G A
WE
ATH
ER
TIG
HT
BU
ILD
ING
- - D
ETA
ILS
AN
D O
MIS
SIO
NS
TO D
RA
WIN
GS
NO
T W
ITH
STA
ND
ING
. A
LL D
RA
WIN
G C
ON
FLIC
TS W
HIC
H M
AY
NO
T A
LLO
W T
HIS
AR
E T
O B
EB
RO
UG
HT
TO T
HE
IMM
ED
IATE
ATT
EN
TIO
N O
F TH
E A
RC
HIT
EC
T A
ND
CO
NS
TRU
CTI
ON
MA
NA
GE
R.
DIS
CR
EP
AN
CIE
S B
ETW
EE
N A
CTU
AL
CO
ND
ITIO
NS
AN
D P
LAN
S S
HA
LL B
E B
RO
UG
HT
TO T
HE
IMM
ED
IATE
ATT
EN
TIO
N O
F TH
E A
RC
HIT
EC
T A
ND
CO
NS
TRU
CTI
ON
MA
NA
GE
R.
ALL
FLO
OR
S W
ITH
DR
AIN
S A
RE
SLO
PE
D A
MIN
IMU
M O
F 1/
8" P
ER
FO
OT
TO D
RA
IN U
NLE
SS
NO
TED
OTH
ER
WIS
E.
LOC
ATI
ON
OF
EX
ISTI
NG
UTI
LITI
ES
AR
E S
HO
WN
TO
TH
E B
ES
T O
F O
UR
KN
OW
LED
GE
. CO
NTR
AC
TOR
SH
ALL
HA
VE
THE
RE
SP
ON
SIB
ILIT
Y O
F V
ER
IFY
ING
IN T
HE
FIE
LD B
EFO
RE
CO
NS
TRU
CTI
ON
STA
RTS
, AN
D C
OO
RD
INA
TIN
G A
LLN
EW
UTI
LITY
LO
CA
TIO
NS
, CO
NN
EC
TIO
NS
, AN
D P
EN
ETR
ATI
ON
S.
ALL
RE
QU
IRE
D E
XIT
S S
HA
LL B
E O
PE
RA
BLE
FR
OM
TH
E IN
SID
E W
ITH
OU
T S
PE
CIA
L K
NO
WLE
DG
E O
R T
HE
US
E O
F A
KE
Y.
PR
OV
IDE
BLO
CK
ING
AS
RE
QU
IRE
D &
CA
LLE
D O
UT
ON
PLA
NS
TO
SE
CU
RE
LY A
NC
HO
R A
LL W
ALL
MO
UN
TED
EQ
UIP
ME
NT
(E.G
., C
AB
INE
TS, T
OIL
ET
RO
OM
, AC
CE
SS
OR
IES
, HA
RD
WA
RE
, ETC
.) B
LOC
KIN
G S
HA
LL P
RO
VID
E A
RIG
ID C
ON
NE
CTI
ON
CA
PA
BLE
OF
SU
PP
OR
TIN
G L
OA
DS
AS
DE
TER
MIN
ED
BY
MA
NU
FAC
TUR
ER
. PR
OV
IDE
SO
LID
BLO
CK
ING
SE
CU
RE
D T
O 2
MA
IN W
ALL
STU
DS
TO
SE
CU
RE
LY S
UP
PO
RT
ALL
WA
LL S
TOP
S (D
OO
R B
UM
PE
R).
THE
GE
NE
RA
L C
ON
TRA
CTO
R S
HA
LL V
ER
IFY
AN
D C
OO
RD
INA
TE W
ITH
ALL
TR
AD
ES
, SIZ
ES
AN
D L
OC
ATI
ON
S O
F A
LLO
PE
NIN
GS
ME
CH
AN
ICA
L &
ELE
CTR
ICA
L E
QU
IPM
EN
T, E
QU
IPM
EN
T P
AD
S O
R B
AS
ES
, AS
WE
LL A
S P
OW
ER
, WA
TER
,A
ND
DR
AIN
INS
TALL
ATI
ON
S, B
EFO
RE
PR
OC
EE
DIN
G W
ITH
WO
RK
. AN
Y C
ON
CE
RN
S O
R S
TRU
CTU
RA
L C
ON
FLIC
TS,
SH
ALL
BE
BR
OU
GH
T TO
TH
E A
TTE
NTI
ON
OF
THE
AR
CH
ITE
CT.
ALL
FLO
OR
OR
WA
LL O
PE
NIN
GS
RE
QU
IRE
D F
OR
PIP
ES
, DU
CTS
, CO
ND
UIT
S, E
TC. S
HA
LL B
E S
EA
LED
IN A
NA
PP
RO
VE
D M
AN
NE
R.
STR
UC
TUR
AL
NO
TES
GO
VE
RN
TY
PIC
AL
CO
ND
ITIO
NS
WH
ETH
ER
OR
NO
T S
PE
CIF
ICA
LLY
DE
TAIL
ED
OR
NO
TED
.
CO
NTR
OL
JOIN
TS S
HA
LL B
E P
RO
VID
ED
IN C
ON
CR
ETE
FLO
OR
SLA
BS
AN
D M
AS
ON
RY
WA
LLS
WH
ETH
ER
OR
NO
TS
PE
CIF
ICA
LLY
RE
FER
EN
CE
D O
N P
LAN
S. T
HE
MA
XIM
UM
AR
EA
PE
RM
ITTE
D B
ETW
EE
N J
OIN
TS S
HA
LL B
E 4
00S
QU
AR
E F
EE
T FO
R R
EIN
FOR
CE
D C
ON
CR
ETE
SLA
BS
, 250
SQ
UA
RE
FE
ET
FOR
NO
N-R
EIN
FOR
CE
D S
LAB
S A
ND
400
SQ
UA
RE
FE
ET
FOR
MA
SO
NR
Y U
NLE
SS
SH
OW
N O
THE
RW
ISE
.
ALL
FIR
E S
PR
INK
LER
, ELE
CTR
ICA
L, M
EC
HA
NIC
AL
AN
D P
LUM
BIN
G W
OR
K S
HA
LL B
E C
ON
CE
ALE
D F
RO
M V
IEW
EX
CE
PT
WH
ER
E E
XP
OS
ED
TO
STR
UC
TUR
E. L
OC
ATE
PIP
ING
AN
D S
UP
PO
RTS
IN A
NE
AT
AN
D C
ON
SIS
TEN
TM
AN
NE
R.
IT IS
TH
E C
ON
TRA
CTO
RS
RE
SP
ON
SIB
ILIT
Y T
O F
OLL
OW
DR
AW
ING
S F
OR
LO
CA
TIO
N O
F E
LEC
TRIC
AL
RE
CE
PTA
CLE
S O
R S
WIT
CH
ES
TO
AV
OID
CA
SE
WO
RK
, DO
OR
S, E
TC.
PR
OV
IDE
FIR
E E
XTI
NG
UIS
HE
RS
IN T
YP
E, S
IZE
, QU
AN
TITY
AN
D L
OC
ATI
ON
S A
S R
EQ
UIR
ED
BY
TH
E B
UIL
DIN
G A
ND
FIR
E D
EP
AR
TME
NTS
.
CO
NTR
AC
TOR
TO
PR
OV
IDE
ALL
LA
BO
R &
EQ
UIP
ME
NT
TO P
ER
FOR
M T
HE
WO
RK
IND
ICA
TED
ON
TH
ES
E D
RA
WIN
GS
.P
ER
MIT
S W
ILL
BE
PR
OV
IDE
D B
Y T
HE
OW
NE
R.
CO
NTR
AC
TOR
SH
ALL
VIS
IT T
HE
SIT
E F
OR
VE
RIF
ICA
TIO
N O
F A
LLC
ON
DIT
ION
S T
HA
T M
AY
AFF
EC
T TH
E P
RO
JEC
T, P
RIO
R T
O T
HE
STA
RT
OF
CO
NS
TRU
CTI
ON
.
ALL
EX
CA
VA
TIO
N A
ND
BA
CK
FILL
SH
ALL
FO
LLO
W A
LL G
EO
TEC
HN
ICA
L (S
OIL
S) R
EP
OR
TS R
EC
OM
ME
ND
ATI
ON
S.
GE
NE
RA
L C
ON
TRA
CTO
R IS
RE
SP
ON
SIB
LE F
OR
AN
Y D
AM
AG
E (A
BO
VE
OR
BE
LOW
GR
AD
E) T
O T
HIS
FA
CIL
ITY
,D
UR
ING
CO
NS
TRU
CTI
ON
.
GE
NE
RA
L C
ON
TRA
CTO
R T
O W
AR
RA
NTY
ALL
WO
RK
AS
OU
TLIN
ED
IN T
HE
RE
QU
ES
T FO
R P
RO
PO
SA
L (R
FP)
THE
SE
PLA
NS
AR
E S
CH
EM
ATI
C O
NLY
. GE
NE
RA
L S
CO
PE
IS D
EFI
NE
D. H
OW
EV
ER
, TH
E O
WN
ER
RE
SE
RV
ES
TH
ER
IGH
T TO
ALT
ER
OR
EX
PA
ND
TH
E S
CO
PE
OF
WO
RK
.
ALL
WO
RK
TO
BE
IN A
CC
OR
DA
NC
E W
ITH
ALL
AP
PLI
CA
BLE
CO
DE
S,
AN
D P
ER
ALL
LO
CA
L R
EQ
UIR
EM
EN
TS.
SIG
NA
GE
CO
NTR
AC
TOR
IS R
ES
PO
NS
IBLE
FO
R P
RO
VID
ING
SH
OP
DR
AW
ING
S T
O O
WN
ER
AN
D C
ITY
AG
EN
CIE
S,
FOR
AP
PR
OV
AL
PR
IOR
TO
FA
BR
ICA
TIO
N A
ND
INS
TALL
ATI
ON
.
GE
NE
RA
L C
ON
TRA
CTO
R T
O P
RO
VID
E T
EM
PO
RA
RY
ON
-SIT
E R
ES
TRO
OM
FA
CIL
ITIE
S D
UR
ING
ALL
CO
NS
TRU
CTI
ON
PH
AS
ES
.
GE
NE
RA
L C
ON
TRA
CTO
R S
HA
LL B
E R
ES
PO
NS
IBLE
FO
R C
OO
RD
INA
TIO
N O
F A
LL T
AS
KS
AN
D IT
EM
S R
EQ
UIR
ED
WIT
HIN
TH
E E
NTI
RE
CO
NS
TRU
CTI
ON
DO
CU
ME
NT
PA
CK
AG
E F
OR
ALL
TR
AD
ES
.
CO
NTR
AC
TOR
SH
ALL
FO
LLO
W R
EQ
UIR
EM
EN
TS O
UTL
INE
D IN
TH
E C
ON
TRA
CTO
R B
ID P
AC
KA
GE
.
WH
EN
TH
E C
ON
TRA
CTO
R B
ELI
EV
ES
TH
AT
ALL
CO
NTR
AC
TUA
L W
OR
K O
N T
HIS
PR
OJE
CT
IS C
OM
PLE
TED
, TH
EY
SH
ALL
NO
TIFY
TH
E A
RC
HIT
EC
T A
ND
CO
NS
TRIC
TIO
N M
AN
AG
ER
(CM
) IN
WR
ITIN
G.
THE
AR
CH
ITE
CT
AN
D C
M S
HA
LLR
ES
PO
ND
PR
OM
PTL
Y W
ITH
AC
CE
PTA
NC
E, O
R A
SP
EC
IFIC
LIS
TIN
G O
F D
EFI
CIE
NC
IES
. CO
NTR
AC
TUA
L W
OR
KS
HA
LL B
E D
EE
ME
D C
OM
PLE
TE T
O A
DE
GR
EE
SU
FFIC
IEN
T TO
PE
RM
IT T
HE
OP
ER
ATO
R T
O C
OM
ME
NC
E IN
ITIA
LO
PE
RA
TIO
N. T
HE
CO
NTR
AC
TOR
SH
ALL
INC
LUD
E IS
SU
AN
CE
TO
TH
E A
RC
HIT
EC
T A
ND
CM
BY
TH
E C
ITY
A V
ALI
D"C
ER
TIFI
CA
TE O
F O
CC
UP
AN
CY
" TO
SU
BS
TAN
TIA
TE P
RO
JEC
T C
OM
PLE
TIO
N.
AT
THE
BE
GIN
NIN
G O
F TH
E P
RO
JEC
T, T
HE
GE
NE
RA
L C
ON
TRA
CTO
R S
HA
LL S
UB
MIT
A C
OM
PLE
TE L
IST
OF
RE
QU
IRE
D "C
ITY
AG
EN
CY
" BU
ILD
ING
PE
RM
IT IN
SP
EC
TIO
NS
PE
R R
EC
EIV
ED
PE
RM
ITS
AN
D S
PE
CIF
IC P
RO
JEC
TS
CO
PE
OF
WO
RK
.
THE
CO
NTR
AC
TOR
SH
ALL
IDE
NTI
FY A
T TH
E T
IME
OF
BID
, AN
Y O
F TH
E IT
EM
S IN
CLU
DE
D IN
TH
IS P
RO
JEC
TR
EQ
UIR
ING
A "S
PE
CIA
L O
RD
ER
", E
XTE
ND
ED
LE
AD
-TIM
E O
R S
PE
CIA
L D
OC
UM
EN
TATI
ON
WIT
H D
RA
WIN
GS
TO
CO
MP
LETE
TH
E A
TTA
CH
ED
SC
OP
E O
F W
OR
K.
AD
EQ
UA
TE T
IME
SH
ALL
BE
GIV
EN
TO
TH
E A
RC
HIT
EC
T TO
RE
VIE
W A
LL S
HO
P D
RA
WIN
GS
AN
D S
UB
MIT
TALS
.
IT S
HA
LL B
E T
HE
RE
SP
ON
SIB
ILIT
Y O
F E
AC
H S
UB
CO
NTR
AC
TOR
INV
OLV
ED
IN T
HIS
PR
OJE
CT,
RE
QU
IRIN
G A
NY
TYP
E O
F FI
ELD
INS
PE
CTI
ON
S D
UR
ING
AN
Y P
AR
T O
F TH
E C
ON
STR
UC
TIO
N P
RO
CE
SS
, TO
BE
PR
ES
EN
T O
N T
HE
CO
NS
TRU
CTI
ON
SIT
E A
T TH
E T
IME
OF
INS
PE
CTI
ON
TO
PR
OV
IDE
DIR
EC
T R
ES
PO
NS
E T
O Q
UE
STI
ON
S A
ND
CO
MM
EN
TS O
F TH
E F
IELD
INS
PE
CTO
R. T
HIS
INC
LUD
ES
BU
T IS
NO
T LI
MIT
ED
TO
ELE
CTR
ICA
L, P
LUM
BIN
G,
ME
CH
AN
ICA
L, S
TRU
CTU
RA
L S
TEE
L, C
ON
CR
ETE
, AS
WE
LL A
S A
NY
AD
DIT
ION
AL
ITE
MS
IND
ICA
TED
BY
TH
EG
EN
ER
AL
CO
NTR
AC
TOR
.
PR
OJE
CT
GE
NE
RA
L N
OTE
S
STD
. MA
TER
IAL
IND
ICA
TIO
NS
STD
. RE
FER
EN
CE
SY
MB
OLS
NO
RTH
THE
GE
NE
RA
L C
ON
TRA
CTO
R IS
RE
SP
ON
SIB
LE T
O M
AIN
TAIN
A D
AIL
Y "O
N-S
ITE
" SA
FETY
LO
G B
OO
K A
S W
ELL
AS
THE
"SIT
E S
AFE
TY P
LAN
"
THE
GE
NE
RA
L C
ON
TRA
CTO
R IS
RE
SP
ON
SIB
LE F
OR
ALL
SA
FETY
AC
TIV
ITIE
S R
EQ
UIR
ED
DA
Y-T
O-D
AY
AN
D S
HA
LLB
E R
ES
PO
NS
IBLE
TO
MA
INTA
IN A
ND
PR
OV
IDE
SA
FE W
OR
KIN
G C
ON
DIT
ION
S F
OR
ALL
OW
NE
R E
MP
LOY
EE
S,
SU
BC
ON
TRA
CTO
R'S
EM
PLO
YE
ES
, VE
ND
OR
S, A
S W
ELL
AS
HIS
OR
HE
R O
WN
EM
PLO
YE
ES
.
AN
Y N
OTI
CE
AB
LE S
AFE
TY V
IOLA
TIO
N S
HA
LL B
E R
EC
OR
DE
D IN
TH
E D
AIL
Y "S
AFE
TY L
OG
" BY
TH
E G
EN
ER
AL
CO
NTR
AC
TOR
.
GE
NE
RA
L C
ON
TRA
CTO
R IS
RE
QU
IRE
D T
O C
OM
PLY
WIT
H A
ND
EN
FOR
CE
ALL
O.S
.H.A
. AN
D O
THE
R R
EC
OG
NIZ
ED
SA
FETY
PR
AC
TIC
E G
UID
ELI
NE
S.
GE
NE
RA
L C
ON
TRA
CTO
R IS
RE
SP
ON
SIB
LE T
O P
RO
VID
E A
DD
ITIO
NA
L O
N-S
ITE
HA
RD
-HA
TS A
T A
LL T
IME
S.
K.
LC
UU.N
.O.
U.B
.C.
UN
FIN
.U
.L.
U.G
.T.
U.G
.E.
UP
PE
RU
NLE
SS
NO
TED
OTH
ER
WIS
EU
NIF
OR
M B
UIL
DIN
G C
OD
EU
NFI
NIS
HE
DU
ND
ER
WR
ITE
RS
LA
BO
RA
TOR
IES
UN
DE
RG
RO
UN
D T
ELE
PH
ON
EU
ND
ER
GR
OU
ND
ELE
CTR
ICA
L
V.F
.V
.C.T
.V
ES
T.
V.I.
F.
WD
.W
/OW
/W
.GL.
WTH
.W
.F.
W.
W.W
.M.
WT.
WP
.W
.C.
WS
CT.
WO
OD
WIT
HO
UT
WIT
HW
IRE
GLA
SS
WID
THW
IDE
FLA
NG
EW
ES
TW
ELD
ED
WIR
E M
ES
HW
EIG
HT
WA
TER
PR
OO
FIN
G, W
EA
THE
RP
RO
OF
WA
TER
CLO
SE
TW
AIN
SC
OT
VIN
YL
FAB
RIC
VIN
YL
CO
MP
OS
ITE
TIL
EV
ES
TIB
ULE
VE
RIF
Y IN
FIE
LD
TYP
.TR
.D.
T.O
.W.
T.O
.S.
T.O
.M.
T.O
.F.
T.O
.D.
T.O
.C.
T.O
.B.
T.&
B.
T.&
G.
T.P
.D.
TOIL
., TL
TTH
K.
THE
RM
O.
TER
.
TYP
ICA
LTR
EN
CH
DR
AIN
TOP
OF
WA
LLTO
P O
F S
TEE
LTO
P O
F M
AS
ON
RY
TOP
OF
FOO
TIN
GTO
P O
F D
EC
KTO
P O
F C
UR
BTO
P O
F B
EA
MTO
P A
ND
BO
TTO
MTO
NG
UE
AN
D G
RO
OV
ETO
ILE
T P
AP
ER
DIS
PE
NS
ER
TOIL
ET
THIC
K, T
HIC
KN
ES
STH
ER
MO
STA
TTE
RR
AZZ
O
DW
G.
DW
R.
DR
.D
.S.
DN
.D
WL.
HO
T W
ATE
RH
OR
IZO
NTA
LH
OS
E B
IBB
H.W
.H
OR
IZ.
H.B
.
RU
ST.
RU
B.
R.O
.R
M.
RFG
.R
.S.
R.D
.L.
R.D
.
RE
T.R
.O.W
.
RE
SIL
.R
EQ
'D.,
RE
QR
LF.
RE
INF.
RE
G.
RE
FR.
RW
D.
R.F
.D.
RC
PT
RU
STI
CA
TIO
NR
UB
BE
RR
OU
GH
OP
EN
ING
RO
OM
RO
OFI
NG
RO
OF
SC
UP
PE
RR
OO
F D
RA
IN L
EA
DE
RR
OO
F D
RA
IN
RE
TUR
NR
IGH
T O
F W
AY
RE
SIL
IEN
TR
EQ
UIR
ED
RE
LIE
FR
EIN
FOR
CE
, RE
INFO
RC
ING
RE
GIS
TER
RE
FER
, RE
FER
EN
CE
RE
DW
OO
D
RE
CE
SS
ED
FLO
OR
DR
AIN
RE
CE
PTA
CLE
KD
.K
IT.
JOIS
T B
EA
RIN
GJO
IST
JOIN
TJA
NIT
OR
KN
OC
K D
OW
NK
ITC
HE
NK
IP =
1,0
00 L
B. F
OR
CE
LOU
VE
RLO
CK
ER
LOC
ATE
, LO
CA
TIO
N
LIG
HT
LEN
GTH
LAV
ATO
RY
LAM
INA
TELA
BO
RA
TOR
Y
EX
T.E
XP
O.
E.J
.E
XP
.E
XIS
T.E
XH
.E
XC
.E
QU
IV.
EQ
UIP
.E
Q.
EN
T.E
NG
R.
EN
CL.
EM
ER
.E
L.E
LEV
.E
.W.C
.E
LEC
.E
.E
.W.
E.F
.E
A.
LVR
.LK
R.
LOC
.
LT.
LGTH
.LA
V.
LAM
.LA
B.
JST.
BR
G.
JST.
JT.
JAN
.
INT.
INS
UL.
I.F.
I.D.
I.M.H
.
IN.
ILLU
M.
INTE
RIO
RIN
SU
LATI
ON
INS
IDE
FA
CE
INS
IDE
DIA
ME
TER
(DIM
EN
SIO
N)
INLE
T M
AN
HO
LE
INC
HIL
LUM
INA
TIO
N
PR
OP
ER
TY L
INE
PR
OP
ER
TY
PR
EFA
BR
ICA
TED
PR
EC
AS
TP
OW
ER
PO
LEP
OU
ND
S P
ER
SQ
UA
RE
INC
HP
OU
ND
S P
ER
SQ
UA
RE
FO
OT
PO
UN
DP
OR
TLA
ND
CE
ME
NT
PO
LYV
INY
L C
HLO
RID
EP
OIN
TP
LYW
OO
D
P.L
.P
RO
P.
PR
EFA
B.
PR
CS
T.P
.P.
P.S
.I.P
.S.F
.LB
.P
.C.
PV
C.
PT.
PLY
WD
.
T.V
.TE
L.T.
BD
.
TELE
VIS
ION
TELE
PH
ON
ETA
CK
BO
AR
D
NU
MB
ER
NO
T TO
SC
ALE
NO
T IN
CO
NTR
AC
TN
OR
THW
ES
TN
OR
THE
AS
TN
OR
THN
OM
INA
L
H.M
.F.
H.M
.H
.C.
HT.
HD
.WD
.H
DW
R.
PLU
MB
ING
PLA
TELAM
INA
TEP
LAS
TIC
PLA
STE
RP
EN
NY
PA
RTI
TIO
N
PA
NE
LP
AIR
PA
INT,
PA
INTE
D
OV
ER
HE
AD
OU
TSID
E F
AC
E
(DIM
EN
SIO
N)
OU
TSID
E D
IAM
ETE
R,
OU
NC
E
OP
PO
SIT
E
OP
EN
ING
ON
CE
NTE
RO
FFIC
EO
BS
CU
RE
GW
BG
YP
.BD
.G
YP
.G
ND
.G
.BM
.G
R.
G.B
.G
L.
GE
N.
GA
.G
.I.G
ALV
.G
AL.
NO
. OR
#N
.T.S
.
N.I.
C.
N.W
.N
.E.
N.
NO
M.
PLB
G.
PL.
P.L
AM
.P
LAS
.P
.P
TN.
PN
L.P
R.
PN
T, P
TD.
O.H
.O
.F.
O.D
.O
Z.
OP
P.
OP
NG
.O
.C.
OFF
.O
BS
.
FUT.
FUR
R.,
FUR
FUR
N.
F.S
.FD
N.
FTG
.FL
UO
R.
F.L.
F.D
.FL
R.
FLA
SH
.FI
XT.
F.S
TP.
F.H
.F.
H.C
.
F.E
.C.
F.E
.F.
DP
R.
F.F.
FIN
.FT
.F.F.
O.W
.F.
O.S
.F.
O.F
.F.
O.C
.FA
B.
SY
M.
SU
SP
.S
UR
F.S
PT.
SU
P.
S.C
.T.
STR
UC
T.S
T.S
.S
TIR
.S
TL.
STA
.S
TD.
S.S
.S
.F.
SQ
.S
PR
.S
P.G
R.
SP
.BLK
.S
PE
CS
.S
.W.
S.B
.C.
S.E
.S
.T.C
.S
.S
.C.
S.D
.S
IM.
SH
.B.
SH
LVS
., S
SH
F.S
HT.
SH
THG
.S
.SK
.S
EC
T.S
CH
ED
.S
A.S
.S
.N.D
.S
AN
.S
.B.
S.R
.
SY
MM
ETR
ICA
LS
US
PE
ND
SU
RFA
CE
SU
PP
OR
TS
UP
PLY
STR
UC
TUR
AL
CLA
Y T
ILE
STR
UC
TUR
AL
STO
RM
SE
WE
RS
TIR
RU
PS
TEE
LS
TATI
ON
STA
ND
AR
DS
TAIN
LES
S S
TEE
LS
QU
AR
E F
EE
TS
QU
AR
ES
PR
INK
LER
SP
LAS
H G
RA
TES
PLA
SH
BLO
CK
SP
EC
IFIC
ATI
ON
SS
OU
THW
ES
TS
OU
THE
RN
BU
ILD
ING
CO
DE
SO
UTH
EA
ST
SO
UN
D T
RA
NS
MIS
SIO
N C
LAS
SS
OU
THS
OLI
D C
OR
ES
OA
P D
ISP
EN
SE
RS
IMIL
AR
SH
OW
ER
BE
NC
HS
HE
LVE
S, S
HE
LVIN
GS
HE
LFS
HE
ET
SH
EA
THIN
GS
ER
VIC
E S
INK
SE
CTI
ON
SC
HE
DU
LES
AN
ITA
RY
SE
WE
RS
AN
ITA
RY
NA
PK
IN D
ISP
EN
SE
RS
AN
ITA
RY
SA
ND
BLA
ST
SA
G R
OD
MU
L.M
TD.
MIS
C.
MIN
.M
M.
M.
M.T
.P.
M.S
.C.
MTL
.M
EM
B.
ME
M.
ME
CH
.M
AX
.M
.O.
MA
S.
MFR
.M
.H.
MU
LLIO
NM
OU
NTE
DM
ISC
ELL
AN
EO
US
MIN
IMU
MM
ILLI
ME
TER
ME
TER
PA
RTI
TIO
NM
ETA
L TO
ILE
T
CO
MP
AR
TME
NT
ME
TAL
SH
OW
ER
ME
TAL
ME
MB
RA
NE
ME
MB
ER
ME
CH
AN
ICA
LM
AX
IMU
MM
AS
ON
RY
OP
EN
ING
MA
SO
NR
YM
AN
UFA
CTU
RE
RM
AN
HO
LE
DR
AW
ING
DR
AW
ER
DR
AIN
DO
WN
SP
OU
TD
OW
ND
OW
EL
EX
TER
IOR
EX
PO
SE
DE
XP
AN
SIO
N J
OIN
TE
XP
AN
SIO
NE
XIS
TIN
GE
XH
AU
ST
EX
CA
VA
TEE
QU
IVA
LEN
TE
QU
IPM
EN
TE
QU
AL
EN
TRA
NC
E, E
NTE
RE
NG
INE
ER
EN
CLO
SE
, EN
CLO
SU
RE
EM
ER
GE
NC
YE
LEV
ATO
RE
LEV
ATI
ON
ELE
CTR
IC W
ATE
R C
OO
LER
ELE
CTR
ICE
AS
TE
AC
H W
AY
EA
CH
FA
CE
EA
CH
B.O
.C.A
BLD
G.
B.L
.B
R.
BR
KT.
B.O
.C.
BO
T.B
.S.
BD
.B
LKG
.B
LK.
BIT
UM
.B
EV
.B
TWN
.B
.M.
BM
.B
SM
T.
C
ON
GR
ES
S O
F A
ME
RIC
AB
UIL
DIN
G O
FFIC
IALS
BU
ILD
ING
BR
ICK
LE
DG
EB
RIC
KB
RA
CK
ET
BO
TTO
M O
F C
UR
BB
OTT
OM
BO
TH S
IDE
SB
OA
RD
BLO
CK
ING
BLO
CK
BIT
UM
INO
US
BE
VE
LB
ETW
EE
NB
EN
CH
MA
RK
BE
AM
BA
SE
ME
NT
D.G
L.D
.A.
DB
L.
DIS
P.
DIM
.D
IFF.
DIA
.D
IAG
.D
TL.,
DE
TD
EP
T.
DE
MO
.
DB
.D
.P.
DP
R.
HO
LLO
W M
ETA
L FR
AM
EH
OLL
OW
ME
TAL
HO
LLO
W C
OR
EH
EIG
HT
HA
RD
WO
OD
HA
RD
WA
RE
GY
PS
UM
WA
LL B
OA
RD
GY
PS
UM
BO
AR
DG
YP
SU
MG
RO
UN
DG
RA
DE
BE
AM
GR
AD
EG
RA
B B
AR
GLA
SS
GE
NE
RA
LG
AU
GE
, GA
GE
GA
LVA
NIZ
ED
IRO
NG
ALV
AN
IZE
DG
ALL
ON
DO
UB
LE G
LAS
SD
OU
BLE
AC
TIN
GD
OU
BLE
DIS
PE
NS
ER
DIM
EN
SIO
ND
IFFU
SE
RD
IAM
ETE
RD
IAG
ON
AL
DE
TAIL
DE
PA
RTM
EN
T
DE
MO
LIS
H, D
EM
OLI
TIO
N
DE
CIB
EL
DA
MP
PR
OO
FD
AM
PE
R
C.Y
.C
NTR
., C
CO
RR
.
C.J
.C
ON
TR.
CO
NT.
CS
.JT.
CO
NS
T.C
ON
N.
C.M
.U.
CO
NC
.
CO
L.C
.W.
CL.
CLR
.C
.O.
CH
AM
.C
.T.
CE
R.
CM
.C
TR.,
CN
TRC
EM
.C
LG.
C.B
.C
.I.P
.C
.I.C
PT.
CA
B.
CE
NTE
R L
INE
CU
BIC
YA
RD
CO
UN
TER
CO
RR
IDO
R
CO
NTR
OL
JOIN
TC
ON
TRA
CTO
RC
ON
TIN
UO
US
CO
NS
TRU
CTI
ON
JO
INT
CO
NS
TRU
CTI
ON
CO
NN
EC
TIO
NC
ON
CR
ETE
MA
SO
NR
Y U
NIT
CO
NC
RE
TE
CO
LUM
NC
OLD
WA
TER
CLO
SE
TC
LEA
RC
LEA
NO
UT
CH
AM
FER
CE
RA
MIC
TIL
EC
ER
AM
ICC
EN
TIM
ETE
RC
EN
TER
CE
ME
NT
CE
ILIN
GC
ATC
H B
AS
INC
AS
T IN
PLA
CE
CA
ST
IRO
NC
AR
PE
TC
AB
INE
T
FUTU
RE
FUR
RIN
GFU
RN
ISH
FULL
SIZ
EFO
UN
DA
TIO
NFO
OTI
NG
FLU
OR
ES
CE
NT
FLO
W L
INE
FLO
OR
DR
AIN
FLO
OR
FLA
SH
ING
FIX
TUR
EFI
RE
STA
ND
PIP
EFI
RE
HY
DR
AN
T, F
IRE
HO
SE
FIR
E H
OS
E C
AB
INE
TC
AB
INE
TFI
RE
EX
TIN
GU
ISH
ER
FI
RE
EX
TIN
GU
ISH
ER
FIR
E D
AM
PE
RFI
NIS
H F
LOO
RFI
NIS
HFE
ET,
FO
OT
FAH
RE
NH
EIT
FAC
E O
F W
ALL
FAC
E O
F S
TUD
FAC
E O
F FI
NIS
HFA
CE
OF
CO
LUM
NFA
BR
ICA
TE
AU
TO.
AS
PH
.A
SB
.A
.DR
.
AR
CH
.
A.B
.A
PP
'D.
ALU
M.
ALT
.A
GG
R.
AD
J.A
DH
.A
.C.T
.A
CO
US
T.A
.P.
A.F
.F.
AU
TOM
ATI
C
AS
PH
ALT
AS
BE
STO
SA
RE
A D
RA
IN
AR
CH
ITE
CT,
AR
CH
ITE
CTU
RA
L
AN
CH
OR
BO
LTA
PP
RO
VE
D
ALU
MIN
UM
ALT
ER
NA
TEA
GG
RE
GA
TEA
DJU
STA
BLE
AD
HE
SIV
EA
CO
US
TIC
AL
CE
ILIN
G T
ILE
AC
OU
STI
CA
LA
CC
ES
S P
AN
EL
AB
OV
E F
INIS
H F
LOO
R
AB
BR
EV
IATI
ON
S
QU
AR
RY
TIL
EQ
.T.
ELE
VA
TIO
N
RE
FLE
CTE
D C
EIL
ING
PLA
N
SY
MB
OL
DE
SIG
NA
TOR
SD
ES
CR
IPTI
ON
SE
CTI
ON
/ P
LAN
#
NA
ME
# #
DW
G
###P1
LB #
#
DW
G
ELE
VD
ES
CR
IPTI
ON
#
DW
G
###
BM
= C
OO
RD
INA
TE, E
LEV
ATI
ON
, OR
STA
TIO
N S
EQ
UE
NC
E D
ES
IGN
ATI
ON
NO
=D
ETA
IL N
UM
BE
RD
WG
= S
HE
ET
NU
MB
ER
ELE
V =
ELE
VA
TIO
N
# =
ALP
HA
NU
ME
RIC
GR
IDD
ES
IGN
ATI
ON
# =
DE
TAIL
NU
MB
ER
DW
G =
SH
EE
T N
UM
BE
R
###
= D
OO
R N
UM
BE
R
# =
EQ
UIP
ME
NT
DE
SIG
NA
TIO
N
DIM
= D
ISTA
NC
E, F
AC
E O
F FR
AM
ING
TO F
AC
E O
F FR
AM
ING
, GR
ID L
INE
TO
GR
ID L
INE
, GR
ID L
INE
TO
FR
AM
ING
ELE
V =
FIN
ISH
GR
AD
E E
LEV
ATI
ON
ELE
V =
EX
ISTI
NG
GR
AD
E E
LEV
ATI
ON
P =
FIN
ISH
DE
SIG
NA
TIO
NF
= FL
OO
R F
INIS
H D
ES
IGN
ATI
ON
B =
BA
SE
DE
SIG
NA
TIO
N
# =
GLA
SS
TY
PE
OR
OP
EN
ING
DE
SIG
NA
TIO
N
# =
NO
TE D
ES
IGN
ATI
ON
INC
OR
PO
RA
TED
INTO
TIT
LE B
LOC
K
# =
PA
RTI
TIO
N T
YP
E D
ES
IGN
ATI
ON
# =
RE
VIS
ION
DE
SIG
NA
TIO
N
NA
ME
= N
AM
E O
F S
PA
CE
# =
RO
OM
DE
SIG
NA
TIO
N
# =
AC
CE
SS
OR
Y D
ES
IGN
ATI
ON
FIN
= F
INIS
H S
CH
ED
ULE
DE
SIG
NA
TIO
N
#= D
ETA
IL N
UM
BE
RD
WG
= S
HE
ET
NU
MB
ER
RE
AD
AN
D U
ND
ER
STA
ND
TH
E S
OIL
S R
EP
OR
T P
RIO
R T
O T
HE
STA
RT
OF
CO
NS
TRU
CTI
ON
.
VE
RIF
Y A
LL IN
VE
RT
ELE
VA
TIO
NS
PR
IOR
TO
INS
TALL
ING
SA
NIT
AR
Y O
R S
TOR
M L
INE
S.
THE
GE
NE
RA
L C
ON
TRA
CTO
R S
HA
LL B
E R
ES
PO
NS
IBLE
FO
R R
EV
IEW
ING
HIS
/HE
R S
UB
CO
NTR
AC
TOR
S B
IDS
TO E
NS
UR
E T
HA
T A
LL IT
EM
S ID
EN
TIFI
ED
ON
TH
ES
E D
RA
WIN
GS
HA
VE
BE
EN
BID
.
MIS
CE
LLA
NE
OU
S S
TEE
L IS
SH
OW
N A
ND
DE
TAIL
ED
ON
TH
E A
RC
HIT
EC
TUR
AL
DR
AW
ING
S O
R S
TRU
CTU
RA
LD
RA
WIN
GS
.
CO
NTR
AC
TOR
AN
D A
LL S
UB
-CO
NTR
AC
TOR
S A
RE
RE
QU
IRE
D T
O H
AV
E F
ULL
KN
OW
LED
GE
OF
THE
CO
DE
AN
D A
LL L
OC
AL
RE
QU
IRE
ME
NTS
. IG
NO
RA
NC
E O
F TH
E C
OD
E A
ND
RE
QU
IRE
ME
NTS
BY
CO
NTR
AC
TOR
OR
AN
Y S
UB
-CO
NTR
AC
TOR
SH
ALL
NO
T G
IVE
RIS
E T
O A
NY
CH
AN
GE
, EX
TRA
S,
OR
CH
AN
GE
OR
DE
RS
AT
THE
CO
ST
OF
THE
OW
NE
R O
R D
EV
ELO
PE
R.
IMP
OR
TAN
T:
B.R
.G.
BE
AR
ING
#
DW
G
NO
=D
ETA
IL N
UM
BE
RD
WG
= S
HE
ET
NU
MB
ER
WD
WW
IND
OW
VFY
VE
NT
VA
C
VE
RIF
YV
EN
TILA
TIO
NV
AC
UU
M
VTR
VE
NT
THR
OU
GH
RO
OF
VE
RT.
VE
RTI
CA
L
UC
UN
DE
R C
OU
NTE
R
UR
.U
RIN
AL
TEM
PTE
MP
ER
ED
TRTM
TTR
EA
TME
NT
SID
LTS
IDE
LIG
HT
RE
V.
RE
F
RE
C
R.
RE
VE
RS
E
RE
FRIG
ER
ATO
R
RE
CE
SS
ED
RA
DIU
S
RD
RO
D
QU
AR
TER
QTR
PA
RTI
CLE
PA
RT
PR
OJE
CT
PR
OJ
AT
(TH
E R
ATE
OF)
AN
GLE
WIT
HO
UT
BY
(AS
6"x
8")
RO
UN
D /
DIA
ME
TER
W/O
LP W/
xØ
PLA
TE
WIT
H
@
Den
tal E
quip
men
t Sup
plie
r
Impo
rtant
not
e fo
llow
ing.
OP
ER
ATO
RY
OP
.
OW
NE
R S
UP
PLI
ED
/ C
ON
TR IN
STA
LLE
DO
SC
I
NA
TUR
AL
GA
SN
ATU
RA
LN
GN
AT
NO
T IN
CO
NTR
AC
T / C
ON
TR IN
STA
LLE
DN
ICIC
MG
ME
DIC
AL
GA
SE
S
LIN
OLE
UM
LIN
LOW
ER
CA
BIN
ET
LIND
IND
ICA
TES
HC
HA
ND
ICA
P(P
ED
)
HD
HE
AV
Y D
UTY
HO
UR
HR
HV
AC
HE
ATI
NG
, CO
OLI
NG
&A
IR C
ON
DIT
ION
ING
GC
GE
NE
RA
L C
ON
TRA
CTO
R
DE
DD
ED
ICA
TED
DE
SD
EN
TAL
EQ
UIP
ME
NT
SU
PP
LIE
R
DR
DO
OR
DW
DIS
HW
AS
HE
R
CA
CO
MP
RE
SS
ED
AIR
CO
OR
DC
OO
RD
INA
TE
BTU
(/H)
BR
ITIS
H T
HE
RM
AL
UN
IT (P
ER
HO
UR
)
AW
IA
RC
H. W
OO
DW
OR
K IN
STI
TUTE
AS
ST
AS
SIS
TAN
T
AN
SI
AM
ER
. NA
T'L
STA
ND
AR
DS
INS
TITU
TE
CC
HA
NN
EL
poin
t of c
oord
inat
ion.
#= E
LEV
ATI
ON
CH
AN
GE
IN IN
CH
ES
PR
OP
OS
ED
DE
NT
AL
OFF
ICE
WIT
H U
NFI
NIS
HE
D O
FFIC
E A
BO
VE
:TH
E P
RO
JEC
T C
ON
SIS
TS O
F O
NE
10,
604
S.F
.OFF
ICE
BU
ILD
ING
, CO
NS
TRU
CTE
D O
F S
TEE
L P
OS
T A
ND
EN
GIN
EE
RE
DW
OO
D B
EA
M F
RA
MIN
G, A
ND
EN
GIN
EE
RE
D W
OO
D J
OIS
TS.
THE
RO
OF
STR
UC
TUR
E W
ILL
CO
NS
IST
OF
PR
E-M
AN
UFA
CTU
RE
D W
OO
D T
RU
SS
ES
WIT
H A
STA
ND
ING
SE
AM
ME
TAL
RO
OF
SY
STE
M.
THE
ME
CH
AN
ICA
LS
YS
TEM
SH
ALL
INC
LUD
E, B
UT
NO
T B
E L
IMIT
ED
TO
, DO
ME
STI
C W
ATE
R D
ISTR
IBU
TIO
N, S
AN
ITA
RY
SE
WE
R A
ND
RO
OF
MO
UN
TED
VE
NTS
. TH
E E
LEC
TRIC
AL
SY
STE
M S
HA
LL IN
CLU
DE
, BU
T N
OT
BE
LIM
ITE
D T
O, E
XTE
RIO
R S
ITE
LIG
HTI
NG
, EX
TER
IOR
AN
D IN
TER
IOR
BU
ILD
ING
LIG
HTI
NG
, ELE
CTR
ICA
L P
AN
ELS
INC
LUD
ING
TH
E S
ER
VIC
EE
NTR
AN
CE
.
DE
SIG
N B
UIL
D E
LEM
EN
TS
:FI
RE
SP
RIN
KLE
R S
YS
TEM
FIR
E A
LAR
M S
YS
TEM
EM
S S
YS
TEM
FO
R M
ETE
RIN
G M
ON
ITO
RIN
G A
ND
RE
PO
RTI
NG
RO
UTI
NG
OF
THE
AU
TO-D
EM
AN
D R
ES
PO
NS
ER
AD
ON
EX
HA
US
T S
YS
TEM
SO
LAR
PH
OTO
-VO
LTA
IC S
YS
TEM
LAN
DS
CA
PE
IRR
IGA
TIO
N S
YS
TEM
PR
IMA
RY
STA
IR IN
EN
TRY
LO
BB
Y
DE
SIG
N-B
UIL
D P
AR
AM
ETE
RS
:FI
RE
SY
STE
M D
ES
IGN
MU
ST
ME
ET
ALL
GO
VE
RN
ING
CO
DE
S.
DE
SIG
NS
MU
ST
BE
SU
BM
ITTE
D T
O O
WN
ER
FO
RR
EV
IEW
AN
D A
PP
RO
VA
L P
RIO
R T
O S
UB
MIT
TIN
G T
O L
OC
AL
RE
VIE
W A
GE
NC
Y F
OR
PE
RM
ITTI
NG
. A
LL C
OS
TS F
OR
DE
SIG
N, E
NG
INE
ER
ING
, SH
OP
DR
AW
ING
S, I
NS
TALL
ATI
ON
, IN
SP
EC
TIO
N, E
TC. T
O B
E P
AID
FO
R B
Y T
HE
CO
NTR
AC
TOR
AN
D IN
CO
RP
OR
ATE
D IN
TO T
HE
SC
HE
DU
LE.
FOR
TH
E F
IRE
ALA
RM
, EA
CH
SY
STE
M M
US
T IN
CLU
DE
NO
N-P
RO
PR
IETA
RY
FIR
E A
LAR
M P
AN
EL
AN
D D
EV
ICE
S S
UC
H A
S, B
UT
NO
T LI
MIT
ED
TO
, FIR
ELI
TE C
ON
TRO
L P
AN
EL,
AD
T M
AN
UA
L P
ULL
STA
TIO
NS
, CH
EM
ETR
ON
IC H
EA
T D
ETE
CTO
RS
, SY
STE
M S
EN
SO
R S
MO
KE
AN
D D
UC
TD
ETE
CTO
RS
; HO
RN
S A
ND
STR
OB
ES
. FO
R T
HE
FIR
E S
PR
INK
LER
SY
STE
M, P
RO
VID
E A
N A
UTO
MA
TIC
WE
T P
IPE
SY
STE
M T
HR
OU
GH
OU
T TH
E E
NTI
RE
BU
ILD
ING
, CO
MP
LETE
IN A
LL A
SP
EC
TS A
ND
RE
AD
Y F
OR
OP
ER
ATI
ON
INC
LUD
ING
TE
ST
AN
D D
RA
IN L
INE
S, P
RE
SS
UR
E G
AU
GE
S, H
AN
GE
RS
, SU
PP
OR
TS, S
IGN
S A
ND
OTH
ER
RE
QU
IRE
DA
PP
UR
TEN
AN
CE
S.
WIR
ING
SH
ALL
BE
PR
OV
IDE
D U
ND
ER
TH
E E
LEC
TRIC
AL
DIV
ISIO
N.
BA
SIS
OF
DE
SIG
N S
HA
LL B
EN
FPA
13
OR
DIN
AR
Y H
AZA
RD
, HO
WE
VE
R, D
ES
IGN
/BU
ILD
CO
NTR
AC
TOR
SH
ALL
VE
RIF
Y A
LL R
EQ
UIR
EM
EN
TS W
ITH
THE
AU
THO
RIT
IES
HA
VIN
G J
UR
ISD
ICTI
ON
PR
IOR
TO
BID
DIN
G, D
ES
IGN
, AN
D C
ON
STR
UC
TIO
N.
SIT
E /
BU
ILD
ING
DE
MO
LIT
ION
:N
ON
E R
EQ
UIR
ED
.
THES
E PL
ANS
ARE
INST
RUM
ENTS
OF
PROF
ESSI
ONAL
SER
VICE
AND
ARE
PROT
ECTE
D BY
COM
MON
LAW
, STA
TUTO
RY A
NDOT
HER
RES
ERVE
D RI
GHTS
INCL
UDIN
G CO
PYRI
GHT.
TH
EY M
AYNO
T BE
REP
RODU
CED
OR U
SED
FOR
ANY
PURP
OSE
WIT
HOU
TTH
E W
RITT
EN C
ONSE
NT O
F TH
E DE
SIGN
PRO
FESS
IONA
L©20
14
FE
FE
FE
SU
ITE
520
5
SU
ITE
120
1
JAN
ITO
R20
8
30'-0
"
SU
ITE
420
4
AR
EA
1,15
3 S
FO
CC
UP
AN
T LO
AD
=
12R
EQ
UIR
ED
EX
IT 1
AR
EA
564
SF
OC
CU
PA
NT
LOA
D =
6
RE
QU
IRE
D E
XIT
1
AR
EA
2,29
5 S
FO
CC
UP
AN
T LO
AD
=
23
RE
QU
IRE
D E
XIT
1
COMMON PATH OF EGRESS TRAVEL 34'-0"
MA
XIM
UM
TR
AV
EL
TO E
XIT
130
'-4"
12 O
C.
2.4"
RE
Q. E
XIT
WID
TH34
" PR
OV
IDE
D
6 O
C.
1.2"
RE
Q. E
XIT
WID
TH34
" PR
OV
IDE
D
8 O
C.
1.6"
RE
Q. E
XIT
WID
TH34
" PR
OV
IDE
D
7 O
C.
1.4"
RE
Q. E
XIT
WID
TH34
" PR
OV
IDE
D
8 O
C.
1.6"
RE
Q. E
XIT
WID
TH34
" PR
OV
IDE
D
21 O
C.
6.3"
RE
Q. E
XIT
STA
IR W
IDTH
44" P
RO
VID
ED
20 O
C.
6" R
EQ
. EX
ITS
TAIR
WID
TH44
" PR
OV
IDE
D
20 O
C. S
EC
ON
D F
LOO
R4.
8" R
EQ
. EX
IT W
IDTH
34" P
RO
VID
ED
EX
IT #
2
OC
CU
PA
NT
LOA
D =
48
SU
ITE
110
1
VE
STI
BU
LE10
0
STA
IR
FIR
E R
ISE
R
STO
RA
GE 51'-9"
MA
XIM
UM
TR
AV
EL
TO E
XIT
118
'-3"
DIAGONAL
DIS
TANCE
= 10
6'-4"
DISTANCE BETWEEN EXITS = 72'-0"
SU
ITE
# 1
01O
CC
UP
AN
T LO
AD
48
NU
MB
ER
OF
EX
IT R
EQ
UIR
ED
: 1
EX
ITS
PR
OV
IDE
D:
2M
AX
IMU
M T
RA
VE
L D
ISTA
NC
E T
O E
XIT
= 11
8'-3
"M
AX
IMU
M C
OM
MO
N P
ATH
OF
EG
RE
SS
TR
AV
EL
TO E
XIT
=
51'-9
"
24 +
20
= 4
4 O
C.
EX
IT #
1
EX
IT #
2
24+
21=
45
OC
.9"
RE
Q. E
XIT
WID
TH34
" PR
OV
IDE
D
FIR
ST
FLO
OR
24
OC
.4.
8" R
EQ
. EX
ITE
XIT
WID
TH34
" PR
OV
IDE
D
24 O
C.
4.8"
RE
Q. E
XIT
WID
TH34
" PR
OV
IDE
D
21 O
C.
4.2"
RE
Q. E
XIT
WID
TH34
" PR
OV
IDE
D
SE
CO
ND
FLO
OR
20
OC
.4.
8" R
EQ
. EX
IT W
IDTH
34" P
RO
VID
ED
MA
XIM
UM
TR
AV
EL
DIS
TAN
CE
TO
EX
IT
LEG
EN
D:
MA
XIM
UM
CO
MM
ON
PA
TH O
F E
GR
ES
S T
RA
VE
L TO
EX
IT
EX
IT L
IGH
T FI
XTU
RE
, WA
LL M
OU
NTE
DD
IRE
CTI
ON
AL
AS
SH
OW
N, S
HA
DE
DQ
UA
DR
AN
T IN
DIC
ATE
FA
CE
S O
F FI
XTU
RE
S.
FIR
E E
XTI
NG
UIS
HE
RS
:1)
PR
OV
IDE
TY
PE
"2A
-10B
C" R
ATE
D F
IRE
EX
TIN
GU
ISH
ER
FO
R E
VE
RY
1,5
00 S
FA
ND
NO
MO
RE
TH
AN
75
FEE
T TR
AV
EL
DIS
TAN
CE
TO
EX
TIN
GU
ISH
ER
AS
AP
PR
OV
ED
BY
TH
E F
IRE
DE
PA
RTM
EN
T.2)
RE
CE
SS
ALL
CA
BIN
ETS
. CE
NTE
R A
T 3'
-6" A
FF3)
PR
OV
IDE
FIR
E R
ATE
D C
AB
INE
TS W
HE
N IN
STA
LLE
D IN
FIR
E R
ATE
D W
ALL
S.
FE
FLO
OR
1 O
CC
UP
AN
T LO
AD
:51
OC
CU
PA
NTS
OFF
ICE
S @
100
SF/
PE
RS
ON
4,77
8 S
F/10
0 =
48
OC
CU
PA
NTS
AC
CE
SS
OR
Y S
PA
CE
@ 3
00 S
F/P
ER
SO
N
693
SF/
300
= 3
OC
CU
PA
NTS
FLO
OR
2 O
CC
UP
AN
T LO
AD
:45
OC
CU
PA
NTS
OFF
ICE
S @
100
SF/
PE
RS
ON
4,01
2 S
F/10
0 =
41
OC
CU
PA
NTS
AC
CE
SS
OR
Y S
PA
CE
@ 3
00 S
F/P
ER
SO
N1,
120
SF/
300
= 4
OC
CU
PA
NTS
TOTA
L B
UIL
DIN
G O
CC
UP
AN
T LO
AD
:
96
OC
CU
PA
NTS
THES
E PL
ANS
ARE
INST
RUM
ENTS
OF
PROF
ESSI
ONAL
SER
VICE
AND
ARE
PROT
ECTE
D BY
COM
MON
LAW
, STA
TUTO
RY A
NDOT
HER
RES
ERVE
D RI
GHTS
INCL
UDIN
G CO
PYRI
GHT.
TH
EY M
AYNO
T BE
REP
RODU
CED
OR U
SED
FOR
ANY
PURP
OSE
WIT
HOU
TTH
E W
RITT
EN C
ONSE
NT O
F TH
E DE
SIGN
PRO
FESS
IONA
L©20
14
CO
MPL
IAN
CE
WIT
H T
HE
2012
IGC
C:
GE
NE
RA
L N
OTE
S:
GE
NE
RA
L C
ON
TRA
CTO
R IS
HE
RE
BY
AD
VIS
ED
TH
AT
CO
MP
LIA
NC
E W
ITH
TH
E 2
012
IGC
C IN
CLU
DIN
G A
PP
LIC
AB
LE A
ME
ND
EM
EN
TS B
YTH
E T
OW
N O
F C
AR
BO
ND
ALE
IS M
AN
DA
TOR
Y A
ND
MU
ST
BE
INC
OR
PO
RA
TED
IN A
LL P
HA
SE
S O
F D
ES
IGN
, BID
DIN
G, C
ON
STR
UC
TIO
N,
AN
D P
OS
T O
CC
UP
AN
CY
OF
THIS
PR
OJE
CT.
TH
E G
EN
ER
AL
CO
NTR
AC
TOR
WIL
L H
AV
E T
HE
PR
IMA
RY
RO
LE O
F M
AN
AG
ING
,V
ER
IFY
ING
, AN
D D
OC
UM
EN
TIN
G C
OM
PLI
AN
CE
WIT
H T
HE
201
2 IG
CC
.
AN
IND
EP
EN
DE
NT
CO
MM
ISS
ION
ING
AG
EN
T W
ILL
BE
RE
TAIN
ED
BY
TH
E O
WN
ER
TO
RE
VIE
W T
HE
DO
CU
ME
NTA
TIO
N A
ND
TE
ST
RE
SU
LTS
PR
OV
IDE
D B
Y T
HE
GE
NE
RA
L C
ON
TRA
CTO
R A
T C
OM
PLE
TIO
N O
F TH
E P
RO
JEC
T TO
CO
NFI
RM
CO
MP
LIA
NC
E W
ITH
TH
EC
OD
E R
EQ
UIR
EM
EN
TS. I
TEM
S N
OT
ME
ETI
NG
TH
E R
EQ
UIR
EM
EN
TS W
ILL
BE
RE
JEC
TED
AN
D T
HE
GE
NE
RA
L C
ON
TRA
CTO
R S
HA
LLH
AV
E T
HE
OB
LIG
ATI
ON
TO
CO
RR
EC
T A
LL N
ON
CO
MP
LIA
NT
ITE
MS
AT
NO
AD
DIT
ION
AL
CO
ST
TO T
HE
OW
NE
R.
ALT
HO
UG
H T
HE
INTE
NT
OF
THE
201
2 IG
CC
HA
S B
EE
N IN
CO
RP
OR
ATE
D IN
TH
IS S
ET
OF
DR
AW
ING
S, C
OM
PLI
AN
CE
WIT
H T
HIS
CO
DE
RE
MA
INS
TH
E R
ES
PO
NS
IBIL
ITY
OF
THE
GE
NE
RA
L C
ON
TRA
CTO
R, A
ND
TH
US
A F
ULL
PR
OA
CTI
VE
INV
OLV
EM
EN
T A
ND
MA
NA
GE
ME
NT
BY
GE
NE
RA
L C
ON
TRA
CTO
R O
F A
LL A
SP
EC
T O
F TH
IS P
RO
JEC
T TO
INS
UR
E C
OM
PLI
AN
CE
WIT
H A
LL R
EQ
UIR
EM
EN
TS O
F TH
E C
OD
EIS
CR
ITIC
AL.
TH
IS IN
CLU
DE
S B
UT
IS N
OT
LIM
ITE
D T
O: P
RE
PA
RIN
G, D
OC
UM
EN
TIN
G A
ND
SU
BM
ITTI
NG
MA
NA
GE
ME
NT
PLA
NS
AS
SE
CIF
IED
IN T
HE
CO
DE
, VE
RIF
YIN
G T
HA
T S
ELE
CTE
D M
ATE
RIA
LS T
O B
E IN
CO
RP
OR
ATE
D IN
TO T
HE
PR
OJE
CT
WIL
L M
EE
T C
OD
E,
MA
NA
GIN
G, S
UP
ER
VIS
ING
AN
D E
DU
CA
TIN
G S
UB
CO
NTR
AC
TOR
ON
CO
MP
LIA
NC
E W
ITH
TH
E R
EQ
UIR
EM
EN
T O
F TH
E C
OD
E,
VE
RIF
YIN
G A
ND
DO
CU
ME
NTI
NG
TH
AT
PU
RC
HA
SE
D M
ATE
RIA
L A
ND
EQ
UIP
ME
NT
ME
ET
THE
CO
DE
RE
QU
IRE
ME
NTS
, MA
NA
GIN
G O
FS
YS
TEM
S T
O B
E D
ES
IGN
-BU
ILT
BY
GC
OR
HIS
SU
BC
ON
TRA
CTO
R, T
ES
TIN
G S
YS
TEM
S A
ND
CO
MP
ON
EN
TS A
S R
EQ
UIR
ED
BY
TH
EC
OD
E, A
SC
ER
TAIN
ING
TH
AT
TES
T R
ES
ULT
S M
EE
T TH
E C
OD
E IN
TEN
T, D
OC
UM
EN
TIN
G A
LL T
ES
T R
ES
ULT
S A
ND
MA
TER
IALS
INC
OR
PO
RA
TED
INTO
TH
E W
OR
K, P
RE
PA
RIN
G O
PE
RA
TIO
NS
MA
NU
ALS
AN
D O
THE
R D
ELI
VE
RA
BLE
S T
O T
HE
OW
NE
R, T
HE
BU
ILD
ING
OFF
ICIA
L, A
ND
TH
E C
OM
MIS
SIO
NIN
G A
GE
NT.
IGN
OR
AN
CE
OF
THE
CO
DE
SHA
LL N
OT
REL
IEF
THE
GC
FR
OM
TH
E R
ESPO
NSI
BIL
ITY
OF
CO
MPL
YIN
G W
ITH
ALL
TH
E A
PPLI
CA
BLE
SEC
TIO
N O
F TH
E 20
12 IG
CC
.
Land
scap
e Irr
igat
ion:
Out
door
land
scap
e irr
igat
ion
syst
ems s
hall
be d
esig
ned
and
inst
alle
d to
redu
ce p
otab
le w
ater
use
by
50 p
erce
nt fr
om a
calc
ulat
ed m
id-s
umm
er b
asel
ine
in a
ccor
danc
e w
ith S
ectio
n 40
4.1.
2 of
the
IGCC
.In
-gro
und
irrig
atio
n sy
stem
shal
l com
ply
with
all
of th
e fo
llow
ing:
1. T
he d
esig
n an
d in
stal
latio
n of
out
door
irrig
atio
n sy
stem
s sha
ll be
und
er th
e su
perv
ision
of a
n irr
igat
ion
prof
essio
nal a
ccre
dite
dor
cer
tifie
d by
an
appr
opria
te lo
cal o
r nat
iona
l bod
y.2.
Lan
dsca
pe ir
rigat
ion
syst
ems s
hall
not d
irect
wat
er o
nto
build
ing
exte
rior s
urfa
ces,
foun
datio
ns o
r ext
erio
r pav
ed su
rfac
es.
Syst
ems s
hall
not g
ener
ate
runo
ff.3.
Irrig
atio
n co
ntro
l sys
tem
shal
l reg
ulat
e irr
igat
ion
base
d on
wea
ther
, clim
atol
ogic
al o
r soi
l moi
stur
e st
atus
dat
a. T
he c
ontr
olle
rsh
all h
ave
inte
grat
ed o
r sep
arat
e se
nsor
s to
susp
end
irrig
atio
n ev
ents
dur
ing
rain
fall.
4. Ir
rigat
ion
zone
s sha
ll be
bas
ed o
n pl
ant w
ater
nee
ds w
ith p
lant
s of s
imila
r nee
d gr
oupe
d to
geth
er. T
urfg
rass
shal
l not
be
grou
ped
with
oth
er p
lant
ings
on
the
sam
e zo
ne.
5. M
icro
-irrig
atio
n zo
nes s
hall
be e
quip
ped
with
pre
ssur
e re
gula
tors
that
ens
ure
zone
pre
ssur
e is
not g
reat
er th
an 4
0 ps
i, fil
ters
,an
d flu
sh e
nd a
ssem
blie
s.6.
Spr
inkl
ers s
hall:
Hav
e no
zzle
s with
mat
ched
pre
cipi
tatio
n ra
tes.
Be
pro
hibi
ted
on la
ndsc
ape
area
s les
s tha
n 4
feet
(123
0 m
m) i
n an
y di
men
sion.
Be
proh
ibite
d on
slop
es g
reat
er th
an 1
uni
t ver
tical
to 4
uni
ts h
orizo
ntal
(25-
perc
ent s
lope
).
Exce
ptio
n: W
here
the
appl
icat
ion
rate
of t
he sp
rinkl
ers i
s les
s tha
n or
equ
al to
0.5
inch
es (1
2.7
mm
) per
hou
r.Be
per
mitt
ed fo
r use
on
turf
gras
s and
cro
p ar
eas o
nly
exce
ptin
g m
icro
spra
ys o
f a fl
ow le
ss th
an 4
5 ga
llons
(170
lite
rs) p
erho
ur.
If of
the
pop-
up c
onfig
urat
ion,
pop
-up
to a
hei
ght o
f not
less
than
4 in
ches
(101
mm
).O
nly
be in
stal
led
in zo
nes c
ompo
sed
excl
usiv
ely
of sp
rinkl
ers a
nd sh
all b
e de
signe
d to
ach
ieve
a lo
wer
qua
rter
dist
ribut
ion
unifo
rmity
of n
ot le
ss th
an 0
.65.
Soil
and
wat
er q
ualit
y pr
otec
tion.
Soil
and
wat
er q
ualit
y sh
all b
e pr
otec
ted
in a
ccor
danc
e w
ith S
ectio
ns 4
05.1
.1 th
roug
h 40
5.1.
6. o
f the
IGCC
Soil
and
wat
er q
ualit
y pr
otec
tion
plan
.A
soil
and
wat
er q
ualit
y pr
otec
tion
plan
shal
l be
subm
itted
by
the
Gene
ral C
ontr
acto
r and
app
rove
d pr
ior t
o co
nstr
uctio
n. T
hepr
otec
tion
plan
shal
l add
ress
the
follo
win
g:1.
A so
ils m
ap, s
ite p
lan,
or g
radi
ng p
lan
that
indi
cate
s des
igna
ted
soil
man
agem
ent a
reas
for a
ll sit
e so
ils, i
nclu
ding
, but
not
limite
d to
:1.
1. S
oils
that
will
be
reta
ined
in p
lace
and
des
igna
ted
as v
eget
atio
n an
d so
il pr
otec
tion
area
s (VS
PAs)
.1.
2. T
opso
ils th
at w
ill b
e st
ockp
iled
for f
utur
e re
use
and
the
loca
tions
for t
he st
ockp
iles.
1.3.
Soi
ls th
at w
ill b
e di
stur
bed
durin
g co
nstr
uctio
n an
d pl
ans t
o re
stor
e di
stur
bed
soils
and
und
erly
ing
subs
oils
to so
il re
fere
nce
cond
ition
s.1.
4. S
oils
that
will
be
rest
ored
and
re-v
eget
ated
.1.
5. S
oils
dist
urbe
d by
pre
viou
s dev
elop
men
t tha
t will
be
rest
ored
in p
lace
and
re-v
eget
ated
.1.
6. L
ocat
ions
for a
ll la
ydow
n an
d st
orag
e ar
eas,
par
king
are
as, h
aul r
oads
and
con
stru
ctio
n ve
hicl
e ac
cess
, tem
pora
ry u
tiliti
esan
d co
nstr
uctio
n tr
aile
r loc
atio
ns.
New
land
scap
ing
inst
alle
d sh
all b
e 10
0 pe
rcen
t nat
ive
or a
dapt
ive
plan
t spe
cies
.
Build
ing
site
was
te m
anag
emen
t pla
n.A
build
ing
site
was
te m
anag
emen
t pla
n sh
all b
e de
velo
ped
and
impl
emen
ted
by th
e GC
to d
iver
t not
less
than
75
perc
ent o
f the
land
-cle
arin
g de
bris
and
exca
vate
d so
ils. L
and-
clea
ring
debr
is in
clud
es ro
ck, t
rees
, stu
mps
and
ass
ocia
ted
vege
tatio
n. T
he p
lan
shal
l inc
lude
pro
visio
ns th
at a
ddre
ss a
ll of
the
follo
win
g:1.
Mat
eria
ls to
be
dive
rted
from
disp
osal
by
effic
ient
usa
ge, r
ecyc
ling
or re
use
on th
e bu
ildin
g sit
e sh
all b
e sp
ecifi
ed.
2. D
iver
ted
mat
eria
ls sh
all n
ot b
e se
nt to
site
s tha
t are
agr
icul
tura
l lan
d, fl
ood
haza
rd a
reas
or g
reen
field
site
s whe
rede
velo
pmen
t is p
rohi
bite
d by
Sec
tion
402.
1 of
the
IGCC
exc
ept w
here
app
rove
d by
the
code
offi
cial.
3. T
he e
ffect
ive
dest
ruct
ion
and
disp
osal
of i
nvas
ive
plan
t spe
cies.
4. W
here
con
tam
inat
ed so
ils a
re re
mov
ed, t
he m
etho
ds o
f rem
oval
and
loca
tion
whe
re th
e so
ils a
re to
be
trea
ted
and
disp
osed
.5.
The
am
ount
of m
ater
ials
to b
e di
vert
ed sh
all b
e sp
ecifi
ed a
nd sh
all b
e ca
lcul
ated
by
wei
ght o
r vol
ume,
but
not
bot
h.7.
Rec
eipt
s or o
ther
doc
umen
tatio
n re
late
d to
div
ersio
n sh
all b
e m
aint
aine
d th
roug
h th
e co
urse
of c
onst
ruct
ion.
Whe
nre
ques
ted
by th
e co
de o
fficia
l, ev
iden
ce o
f div
ersio
n sh
all b
e pr
ovid
ed.
Cons
truc
tion
was
te.
Cons
truc
tion
mat
eria
ls an
d w
aste
and
har
dsca
pe m
ater
ials
rem
oved
dur
ing
site
prep
arat
ion
shal
l be
man
aged
in a
ccor
danc
ew
ith S
ectio
n 50
3 of
the
IGCC
.
Stor
age
and
hand
ling
of m
ater
ials
.M
ater
ials
stor
ed a
nd h
andl
ed o
nsite
dur
ing
cons
truc
tion
shal
l com
ply
with
the
appl
icab
le m
anuf
actu
rer's
prin
ted
inst
ruct
ions
.W
here
man
ufac
ture
r's p
rinte
d in
stru
ctio
ns a
re n
ot a
vaila
ble,
app
rove
d st
anda
rds o
r gui
delin
es sh
all b
e fo
llow
ed.
Cons
truc
tion
phas
e m
oist
ure
cont
rol.
Poro
us o
r fib
rous
mat
eria
ls an
d ot
her m
ater
ials
subj
ect t
o m
oist
ure
dam
age
shal
l be
prot
ecte
d fr
om m
oist
ure
durin
g th
eco
nstr
uctio
n ph
ase.
Mat
eria
l dam
aged
by
moi
stur
e or
that
are
visi
bly
colo
nize
d by
fung
i eith
er p
rior t
o de
liver
y or
dur
ing
the
cons
truc
tion
phas
e sh
all b
e cl
eane
d an
d dr
ied
or, w
here
dam
age
cann
ot b
e co
rrec
ted
by su
ch m
eans
, sha
ll be
rem
oved
and
repl
aced
.Co
nstr
uctio
n m
ater
ial a
nd w
aste
man
agem
ent p
lan.
Not
less
than
50
perc
ent o
f non
haza
rdou
s con
stru
ctio
n w
aste
shal
l be
dive
rted
from
disp
osal
, exc
ept w
here
oth
er p
erce
ntag
esar
e in
dica
ted
in T
able
302
.1 o
f the
IGCC
. A C
onst
ruct
ion
Mat
eria
l and
Was
te M
anag
emen
t Pla
n sh
all b
e de
velo
ped
and
impl
emen
ted
by th
e GC
to re
cycl
e or
salv
age
cons
truc
tion
mat
eria
ls an
d w
aste
. The
Con
stru
ctio
n M
ater
ial a
nd W
aste
Man
agem
ent P
lan
shal
l com
ply
with
all
of th
e fo
llow
ing:
1. T
he lo
catio
n fo
r col
lect
ion,
sepa
ratio
n an
d st
orag
e of
recy
clab
le c
onst
ruct
ion
was
te sh
all b
e in
dica
ted.
2. M
ater
ials
to b
e di
vert
ed fr
om d
ispos
al b
y ef
ficie
nt u
sage
, rec
yclin
g, re
use,
man
ufac
ture
r's re
clam
atio
n, o
r sal
vage
for f
utur
eus
e, d
onat
ion
or sa
le sh
all b
e sp
ecifi
ed.
3. T
he p
erce
ntag
e of
mat
eria
ls to
be
dive
rted
shal
l be
spec
ified
and
shal
l be
calc
ulat
ed b
y w
eigh
t or v
olum
e, b
ut n
ot b
oth.
4. R
ecei
pts o
r oth
er d
ocum
enta
tion
rela
ted
to d
iver
sion
shal
l be
mai
ntai
ned
thro
ugh
the
cour
se o
f con
stru
ctio
n. W
here
requ
este
d by
the
code
offi
cial,
evid
ence
of d
iver
sion
shal
l be
prov
ided
.
For t
he p
urpo
ses o
f thi
s sec
tion,
con
stru
ctio
n m
ater
ials
and
was
te sh
all i
nclu
de a
ll m
ater
ials
deliv
ered
to th
e sit
e an
d in
tend
edfo
r ins
talla
tion
prio
r to
the
issua
nce
of th
e ce
rtifi
cate
of o
ccup
ancy
, inc
ludi
ng re
late
d pa
ckag
ing.
Con
stru
ctio
n an
d w
aste
mat
eria
ls sh
all n
ot in
clud
e la
nd-c
lear
ing
debr
is, e
xcav
ated
soils
and
fill
and
base
mat
eria
ls su
ch a
s, b
ut n
ot li
mite
d to
, top
soil,
sand
and
gra
vel.
Land
-cle
arin
g de
bris
shal
l inc
lude
tree
s, st
umps
, roc
ks, a
nd v
eget
atio
n. E
xcav
ated
soil,
fill
mat
eria
l and
land
-cle
arin
g de
bris
shal
l be
man
aged
in a
ccor
danc
e w
ith S
ectio
n 40
6.1
of th
e IG
CC.
Not
less
than
55
perc
ent o
f the
tota
l bui
ldin
g m
ater
ials
used
in th
e pr
ojec
t, ba
sed
on m
ass,
vol
ume
or c
ost,
shal
l com
ply
with
Sect
ion
505.
2.1,
505
.2.2
, 505
.2.3
, 505
.2.4
or 5
05.2
.5 o
f the
IGCC
. Whe
re a
mat
eria
l com
plie
s with
mor
e th
an o
ne se
ctio
n, th
em
ater
ial v
alue
shal
l be
mul
tiplie
d by
the
num
ber o
f sec
tions
that
it c
ompl
ies w
ith. T
he v
alue
of t
otal
bui
ldin
g m
ater
ial m
ass,
volu
me
or c
ost s
hall
rem
ain
cons
tant
rega
rdle
ss o
f whe
ther
mat
eria
ls ar
e ta
bula
ted
in m
ore
than
one
sect
ion.
The
mer
cury
con
tent
in la
mps
shal
l com
ply
with
Sec
tion
506.
2 or
506
.3 o
f the
IGCC
.Ex
cept
ion:
App
lianc
e, b
lack
ligh
t, bu
g, c
olor
ed, g
erm
icid
al, p
lant
, sha
tter
-res
istan
t/sh
atte
rpro
of/s
hatt
erpr
otec
ted,
show
case
, UV,
T-8
and
T-12
lam
ps w
ith a
col
or re
nder
ing
inde
x of
87
or h
ighe
r, la
mps
with
RDC
bas
es, a
nd la
mps
use
d fo
r spe
cial
-nee
ds li
ghtin
gfo
r ind
ivid
uals
with
exc
eptio
nal n
eeds
.
Moi
stur
e pr
even
tativ
e m
easu
res s
hall
be in
spec
ted
in a
ccor
danc
e w
ith IG
CC S
ectio
ns 9
02 a
nd 9
03 fo
r the
cat
egor
ies l
isted
inIte
ms 1
thro
ugh
7. In
spec
tions
shal
l be
exec
uted
in a
met
hod
and
at a
freq
uenc
y as
list
ed in
IGCC
Tab
le 9
03.1
.1.
Fou
ndat
ion
sub-
soil
drai
nage
syst
em.
2. F
ound
atio
n w
ater
proo
fing.
3. F
ound
atio
n da
mpp
roof
ing.
4. U
nder
slab
wat
er v
apor
pro
tect
ion.
5. F
lash
ings
: Win
dow
s, e
xter
ior d
oors
, sky
light
s, w
all f
lash
ing
and
drai
nage
syst
ems.
6. E
xter
ior w
all c
over
ings
.7.
Roo
f cov
erin
gs, r
oof d
rain
age,
and
flas
hing
s
Ener
gy C
onse
rvat
ion‚
Effi
cien
cy a
nd C
O2e
Em
issi
on R
educ
tion
Build
ings
des
igne
d on
a p
resc
riptiv
e ba
sis sh
all c
ompl
y w
ith th
e re
quire
men
ts o
f IGC
C Se
ctio
ns 6
05, 6
06, 6
07, 6
08, 6
09, 6
10 a
nd61
1.Th
e Bu
ildin
g sh
all b
e pr
ovid
ed w
ith m
eter
ing
com
plyi
ng w
ith IG
CC S
ectio
n 60
3, a
nd c
omm
issio
ning
com
plyi
ng w
ith IG
CC S
ectio
n61
1. T
he b
uild
ing
shal
l be
prov
ided
with
aut
omat
ed-d
eman
d re
spon
se c
ompl
ying
with
IGCC
Sec
tion
604.
The
ener
gy d
istrib
utio
n sy
stem
shal
l be
desig
ned
and
cons
truc
ted
to a
ccom
mod
ate
the
futu
re in
stal
latio
n of
sub-
met
ers a
ndot
her a
ppro
ved
devi
ces i
n ac
cord
ance
with
IGCC
Sec
tion
603.
4. T
his i
nclu
des,
but
is n
ot li
mite
d to
, pro
vidi
ng a
cces
s to
dist
ribut
ion
lines
and
ens
urin
g ad
equa
te sp
ace
for t
he in
stal
latio
n of
sub-
met
ers a
nd o
ther
app
rove
d de
vice
s.
A bu
ildin
g en
ergy
man
agem
ent a
nd c
ontr
ol sy
stem
(EM
CS) s
hall
be p
rovi
ded
and
inte
grat
ed w
ith b
uild
ing
HVAC
syst
ems c
ontr
ols
and
light
ing
syst
ems c
ontr
ols t
o re
ceiv
e an
ope
n an
d in
tero
pera
ble
auto
mat
ed d
eman
d-re
spon
se (A
uto-
DR) r
elay
or I
nter
net
signa
l. Bu
ildin
g HV
AC a
nd li
ghtin
g sy
stem
s and
spec
ific
build
ing
ener
gy-u
sing
com
pone
nts s
hall
inco
rpor
ate
prep
rogr
amm
edde
man
d re
spon
se st
rate
gies
that
are
aut
omat
ed w
ith a
dem
and
resp
onse
aut
omat
ion
Inte
rnet
soft
war
e cl
ient
.Al
l bui
ldin
gs sh
all b
e re
quire
d to
roug
h-in
AU
TO-D
R, in
clud
ing:
ther
mos
tat w
ire to
all
appl
ianc
es a
nd c
ondu
it m
eter
to e
lect
rical
room
.
The
build
ing
ther
mal
env
elop
e sh
all b
e du
rabl
y se
aled
to li
mit
air l
eaka
ge in
acc
orda
nce
with
Sec
tion
C402
.4 o
f the
Inte
rnat
iona
lEn
ergy
Con
serv
atio
n Co
de a
nd th
e pr
ovisi
ons o
f thi
s sec
tion.
A co
ntin
uous
air
barr
ier s
hall
be p
rovi
ded
acco
rdan
ce w
ith S
ectio
n C4
02.4
.1 o
f the
Inte
rnat
iona
l Ene
rgy
Cons
erva
tion
Code
. The
exce
ptio
n in
Sec
tion
C402
.4.1
of t
he In
tern
atio
nal E
nerg
y Co
nser
vatio
n Co
de sh
all n
ot a
pply
.
2012
IGC
C R
EQ
UIR
EM
EN
TS
The
build
ing
ther
mal
env
elop
e ai
r tig
htne
ss sh
all b
e co
nsid
ered
to b
e ac
cept
able
whe
re th
e te
sted
air
leak
age
of th
e to
tal a
rea
of th
e bu
ildin
g th
erm
al e
nvel
ope
is le
ss th
an 0
.25
cfm
/ft2
und
er a
pre
ssur
e di
ffere
ntia
l of 0
.3 in
wat
er c
olum
n (1
.57
lb/f
t2.
Test
ing
shal
l occ
ur a
fter
roug
h-in
and
aft
er in
stal
latio
n of
pen
etra
tions
of t
he b
uild
ing
enve
lope
, inc
ludi
ng p
enet
ratio
ns fo
rut
ilitie
s, h
eatin
g, v
entil
atin
g an
d ai
r-co
nditi
onin
g (H
VAC)
syst
ems,
plu
mbi
ng, a
nd e
lect
rical
equ
ipm
ent a
nd a
pplia
nces
. Tes
ting
shal
l be
done
in a
ccor
danc
e w
ith A
STM
E 7
79.
The
tota
l lig
htin
g in
the
elev
ator
cab
shal
l be
not l
ess t
han
35 lu
men
s per
wat
t, ba
sed
on th
e to
tal l
umen
s fro
m la
mps
div
ided
by th
e to
tal w
atta
ge o
f the
lum
inai
res i
n th
e ca
b, b
ut n
ot in
clud
ing
lum
inai
res o
f sig
nals
and
disp
lays
.In
duct
ion
mot
or w
ith a
Cla
ss IE
2 ef
ficie
ncy
ratin
g, a
s def
ined
by
IEC
EN 6
0034
-30,
or a
ltern
ativ
e te
chno
logi
es, s
uch
aspe
rman
ent m
agne
t syn
chro
nous
mot
ors t
hat h
ave
equa
l or b
ette
r effi
cien
cy, s
hall
be u
sed
for t
he e
leva
tor.
Tran
smiss
ions
shal
lno
t red
uce
the
effic
ienc
y of
the
com
bine
d m
otor
/tra
nsm
issio
n be
low
that
show
n fo
r the
Cla
ss IE
2 m
otor
. Gea
rless
mac
hine
ssh
all b
e as
sum
ed to
hav
e a
100-
perc
ent t
rans
miss
ion
effic
ienc
y. P
oten
tial e
nerg
y re
leas
ed d
urin
g m
otio
n sh
all b
e re
cove
red.
The
build
ing
shal
l be
equi
pped
with
a so
lar p
hoto
volta
ic re
new
able
ene
rgy
syst
em th
at h
as th
e ca
paci
ty to
pro
vide
not
less
than
10
perc
ent o
f the
tota
l cal
cula
ted
annu
al e
nerg
y us
e of
the
build
ings
as d
eter
min
ed b
y th
e m
echa
nica
l eng
inee
r. Th
eph
otov
olta
ic sy
stem
shal
l be
Desig
n-Bu
ild b
y th
e GC
usin
g a
com
pete
nt d
esig
n en
gine
er sp
ecia
lized
in p
hoto
volta
ic sy
stem
s.Th
e in
stal
latio
n, in
spec
tion,
mai
nten
ance
, rep
air a
nd re
plac
emen
t of s
olar
pho
tovo
ltaic
syst
ems a
nd sy
stem
com
pone
nts s
hall
com
ply
with
the
man
ufac
ture
r's in
stru
ctio
ns, I
GCC
Sect
ion
610.
2.2.
1, th
e In
tern
atio
nal F
ire C
ode,
the
Inte
rnat
iona
l Bui
ldin
gCo
de a
nd N
FPA
70.
Sola
r pho
tovo
ltaic
syst
ems s
hall
be te
sted
on
inst
alla
tion
to v
erify
that
the
inst
alle
d pe
rfor
man
ce m
eets
the
desig
nsp
ecifi
catio
ns. A
repo
rt o
f the
test
ed p
erfo
rman
ce sh
all b
e pr
ovid
ed to
the
build
ing
owne
r and
Com
miss
ioni
ng A
gent
.Th
e PV
syst
em sh
all b
e m
eter
ed a
nd m
onito
red
in a
ccor
danc
e w
ith IG
CC S
ectio
ns 6
10.5
.1 a
nd 6
10.5
.2 a
nd s
hall
be m
onito
red
to m
easu
re th
e pe
ak e
lect
ric o
r the
rmal
ene
rgy
gene
rate
d du
ring
the
build
ing'
s ant
icip
ated
pea
k el
ectr
ic o
r fos
sil fu
elco
nsum
ptio
n pe
riod
in a
ccor
danc
e w
ith IG
CC S
ectio
n 60
3.EN
ERGY
SYS
TEM
S CO
MM
ISSI
ON
ING
AND
COM
PLET
ION
With
in 2
0 da
ys fr
om a
ppro
val c
ondu
ctin
g th
e fin
al m
echa
nica
l ins
pect
ion
the
GC sh
all p
rovi
de th
e O
wne
r and
the
Com
miss
ioni
ng A
gent
all
mec
hani
cal s
yste
m d
ocum
enta
tion,
man
uals,
test
ing
and
bala
ncin
g re
port
s, a
nd a
repo
rt o
f all
varia
tion
and
field
cha
nges
form
the
orig
inal
con
stru
ctio
n do
cum
ents
. The
GC
shal
l sch
edul
e a
conv
enie
nt ti
me
to m
eet o
n sit
ew
ith th
e Co
mm
issio
n Ag
ent a
nd to
per
form
any
add
ition
al te
st re
ques
ted
by C
omm
issio
ning
Age
nt a
s nec
essa
ry fo
r the
com
plet
ing
the
Com
miss
ioni
ng C
ertif
icat
ion.
With
in 6
0 da
ys fr
om a
ppro
val c
ondu
ctin
g th
e fin
al m
echa
nica
l ins
pect
ion,
the
Com
miss
ioni
ng A
gent
shal
l pro
vide
evi
denc
e of
mec
hani
cal s
yste
ms c
omm
issio
ning
and
com
plet
ion
of th
e m
echa
nica
l sys
tem
inst
alla
tion
to th
e co
de o
fficia
l, in
acc
orda
nce
with
the
Inte
rnat
iona
l Ene
rgy
Cons
erva
tion
Code
.
Draw
ing
note
s sha
ll cl
early
indi
cate
pro
visio
ns fo
r com
miss
ioni
ng a
nd c
ompl
etio
n re
quire
men
ts in
acc
orda
nce
with
this
sect
ion
and
are
perm
itted
to re
fer t
o sp
ecifi
catio
ns fo
r fur
ther
requ
irem
ents
. Cop
ies o
f all
docu
men
tatio
n sh
all b
e gi
ven
to th
e ow
ner
and
mad
e av
aila
ble
to th
e co
de o
fficia
l upo
n re
ques
t.A
com
miss
ioni
ng p
lan
shal
l be
deve
lope
d by
the
Com
miss
ioni
ng A
gent
and
shal
l inc
lude
as a
min
imum
all
of th
e fo
llow
ing
item
s:1.
A n
arra
tive
desc
ribin
g th
e ac
tiviti
es th
at w
ill b
e ac
com
plish
ed d
urin
g ea
ch p
hase
of c
omm
issio
ning
, inc
ludi
ng g
uida
nce
onw
ho a
ccom
plish
es th
e ac
tiviti
es a
nd h
ow th
ey a
re c
ompl
eted
.2.
Equ
ipm
ent a
nd sy
stem
s to
be te
sted
incl
udin
g, b
ut n
ot li
mite
d to
, the
spec
ific
equi
pmen
t, ap
plia
nces
or s
yste
ms t
o be
test
edan
d th
e nu
mbe
r and
ext
ent o
f tes
ts.
3. F
unct
ions
to b
e te
sted
incl
udin
g, b
ut n
ot li
mite
d to
, cal
ibra
tions
and
eco
nom
izer c
ontr
ols.
4. C
ondi
tions
und
er w
hich
the
test
shal
l be
perf
orm
ed in
clud
ing,
but
not
lim
ited
to, a
ffirm
atio
n of
win
ter a
nd su
mm
er d
esig
nco
nditi
ons a
nd fu
ll ou
tsid
e ai
r.5.
Mea
sura
ble
crite
ria fo
r per
form
ance
.Th
e GC
shal
l cau
se th
e HV
AC sy
stem
s to
be b
alan
ced
in a
ccor
danc
e w
ith g
ener
ally
acc
epte
d en
gine
erin
g st
anda
rds.
Air
and
wat
er fl
ow ra
tes s
hall
be m
easu
red
and
adju
sted
to d
eliv
er fi
nal f
low
rate
s with
in th
e to
lera
nces
pro
vide
d in
the
prod
uct
spec
ifica
tions
. Tes
t and
bal
ance
act
iviti
es sh
all i
nclu
de, a
t a m
inim
um, t
he p
rovi
sions
of I
GCC
Sect
ions
611
.1.2
.1 a
nd 6
11.1
.2.2
.Ea
ch su
pply
air
outle
t and
zone
term
inal
dev
ice
shal
l be
equi
pped
with
a m
eans
for a
ir ba
lanc
ing
in a
ccor
danc
e w
ith th
eIn
tern
atio
nal M
echa
nica
l Cod
e. D
ischa
rge
dam
pers
are
pro
hibi
ted
on c
onst
ant v
olum
e fa
ns a
nd v
aria
ble
volu
me
fans
with
mot
ors o
f 10
hp a
nd la
rger
. Air
syst
ems s
hall
be b
alan
ced
in a
man
ner t
o fir
st m
inim
ize th
rott
ling
loss
es th
en, f
or fa
ns w
ithsy
stem
pow
er o
f gre
ater
than
1 h
p, fa
n sp
eed
shal
l be
adju
sted
to m
eet d
esig
n flo
w c
ondi
tions
.Fu
nctio
nal p
erfo
rman
ce te
stin
g sh
all b
e in
acc
orda
nce
with
the
requ
irem
ents
of I
GCC
Sect
ions
611
.1.3
.1, 6
11.1
.3.2
and
611.
1.3.
3.Eq
uipm
ent:
Equi
pmen
t fun
ctio
nal p
erfo
rman
ce te
stin
g sh
all d
emon
stra
te th
e in
stal
latio
n an
d op
erat
ion
of c
ompo
nent
s,sy
stem
s, a
nd sy
stem
-to-
syst
em in
terf
acin
g re
latio
nshi
ps in
acc
orda
nce
with
app
rove
d pl
ans a
nd sp
ecifi
catio
ns so
that
oper
atio
n, fu
nctio
n, a
nd m
aint
enan
ce se
rvic
eabi
lity
for e
ach
of th
e co
mm
issio
ned
syst
ems i
s con
firm
ed. T
estin
g sh
all i
nclu
deal
l spe
cifie
d m
odes
of c
ontr
ol a
nd se
quen
ce o
f ope
ratio
n, in
clud
ing
unde
r ful
l-loa
d, p
art-
load
and
all
of th
e fo
llow
ing
emer
genc
y co
nditi
ons:
1. E
ach
mod
e as
des
crib
ed in
the
sequ
ence
of o
pera
tion.
2. R
edun
dant
or a
utom
atic
bac
kup
mod
e.3.
Per
form
ance
of a
larm
s.4.
Mod
e of
ope
ratio
n up
on a
loss
of p
ower
and
rest
orat
ion
of p
ower
Cont
rols
: HVA
C co
ntro
l sys
tem
s sha
ll be
test
ed to
doc
umen
t tha
t con
trol
dev
ices
, com
pone
nts,
equ
ipm
ent,
and
syst
ems a
reca
libra
ted,
adj
uste
d an
d op
erat
ed in
acc
orda
nce
with
the
appr
oved
pla
ns a
nd sp
ecifi
catio
ns. S
eque
nces
of o
pera
tion
shal
l be
func
tiona
lly te
sted
to d
ocum
ent t
hat t
hey
oper
ate
in a
ccor
danc
e w
ith th
e ap
prov
ed p
lans
and
spec
ifica
tions
.Ec
onom
izer
s: A
ir ec
onom
izers
shal
l und
ergo
a fu
nctio
nal t
est t
o de
term
ine
that
they
ope
rate
in a
ccor
danc
e w
ith th
em
anuf
actu
rer's
spec
ifica
tions
.
A pr
elim
inar
y re
port
of c
omm
issio
ning
test
pro
cedu
res a
nd re
sults
shal
l be
com
plet
ed a
nd c
ertif
ied
by th
e Co
mm
issio
ning
Agen
t and
pro
vide
d to
the
GC a
nd b
uild
ing
owne
r. Th
e re
port
shal
l be
iden
tifie
d as
"Pre
limin
ary
Com
miss
ioni
ng R
epor
t” a
ndsh
all i
dent
ify a
ll of
the
follo
win
g:1.
Item
izatio
n of
def
icie
ncie
s fou
nd d
urin
g te
stin
g re
quire
d by
this
sect
ion
that
hav
e no
t bee
n co
rrec
ted
at th
e tim
e of
repo
rtpr
epar
atio
n.2.
Def
erre
d te
sts t
hat c
anno
t be
perf
orm
ed a
t the
tim
e of
repo
rt p
repa
ratio
n be
caus
e of
clim
atic
con
ditio
ns.
3. C
limat
ic c
ondi
tions
requ
ired
for p
erfo
rman
ce o
f the
def
erre
d te
sts.
Build
ings
, or p
ortio
ns th
ereo
f, sh
all n
ot p
ass t
he fi
nal m
echa
nica
l ins
pect
ion
until
such
tim
e as
the
code
offi
cial h
as re
ceiv
ed a
lett
er o
f tra
nsm
ittal
from
the
GC a
ckno
wle
dgin
g th
at th
e bu
ildin
g ow
ner h
as re
ceiv
ed th
e Pr
elim
inar
y Co
mm
issio
ning
Rep
ort.
At th
e re
ques
t of t
he co
de o
fficia
l, a
copy
of t
he P
relim
inar
y Co
mm
issio
ning
Rep
ort s
hall
be m
ade
avai
labl
e fo
r rev
iew
.
The
GC sh
all p
rom
ptly
rect
ify a
ll de
ficie
ncie
s ide
ntifi
ed in
the
Prel
imin
ary
Com
miss
ioni
ng R
epor
t, an
d co
mpl
ete
all o
ther
test
sor
re-t
estin
g as
requ
este
d by
the
Com
miss
ioni
ng A
gent
.
Upo
n sa
tisfa
ctor
y co
mpl
etio
n of
all
defic
ienc
ies i
dent
ified
in th
e Pr
elim
inar
y Co
mm
issio
ning
Rep
ort t
he C
omm
issio
ning
Age
ntsh
all i
ssue
a si
gned
and
seal
ed c
ertif
icat
ion,
doc
umen
ting
that
the
mec
hani
cal a
nd se
rvic
e w
ater
hea
ting
syst
ems c
ompl
y w
ithSe
ctio
ns C
403
and
C404
of t
he In
tern
atio
nal E
nerg
y Co
nser
vatio
n Co
de, w
hich
shal
l be
prov
ided
by
the
GC to
the
code
offi
cial.
COM
PLET
ION
REQ
UIR
EMEN
TSW
ithin
90
days
of t
he d
ate
of re
ceip
t of t
he c
ertif
icat
e of
occ
upan
cy th
e GC
sha
ll pr
ovid
e th
e bu
ildin
g ow
ner t
he fo
llow
ing:
Draw
ings
: Con
stru
ctio
n do
cum
ents
that
incl
ude
the
loca
tion
of a
nd p
erfo
rman
ce d
ata
pert
aini
ng to
eac
h pi
ece
of e
quip
men
t.M
anua
ls: A
n op
erat
ing
and
mai
nten
ance
man
ual i
n ac
cord
ance
with
indu
stry
-acc
epte
d st
anda
rds s
hall
be p
rovi
ded
and
shal
lin
clud
e al
l of t
he fo
llow
ing:
1. S
ubm
ittal
dat
a st
atin
g eq
uipm
ent s
ize a
nd se
lect
ed o
ptio
ns fo
r eac
h pi
ece
of e
quip
men
t req
uirin
g m
aint
enan
ce.
2. M
anuf
actu
rer's
ope
ratio
n m
anua
ls an
d m
aint
enan
ce m
anua
ls fo
r eac
h pi
ece
of e
quip
men
t req
uirin
g m
aint
enan
ce, e
xcep
teq
uipm
ent n
ot fu
rnish
ed a
s par
t of t
he b
uild
ing
proj
ect.
Requ
ired
rout
ine
mai
nten
ance
shal
l be
clea
rly id
entif
ied.
3. N
ames
and
add
ress
es o
f not
less
than
one
serv
ice
agen
cy.
A sy
stem
s man
ual s
hall
be p
rovi
ded
and
shal
l inc
lude
all
of th
e fo
llow
ing:
1. H
VAC
cont
rols
syst
em m
aint
enan
ce a
nd c
alib
ratio
n in
form
atio
n, in
clud
ing
wiri
ng d
iagr
ams,
sche
mat
ics,
and
con
trol
sequ
ence
des
crip
tions
. Des
ired
or fi
eld-
dete
rmin
ed se
tpoi
nts s
hall
be p
erm
anen
tly re
cord
ed o
n co
ntro
l dra
win
gs a
tco
ntro
l dev
ices
or,
for d
igita
l con
trol
syst
ems,
in p
rogr
amm
ing
com
men
ts.
2. A
com
plet
e na
rrat
ive
of h
ow e
ach
syst
em is
inte
nded
to o
pera
te, i
nclu
ding
reco
mm
ende
d se
tpoi
nts,
seas
onal
chan
geov
er in
form
atio
n an
d em
erge
ncy
shut
dow
n op
erat
ion.
3. C
ontr
ol se
quen
ce d
escr
iptio
ns fo
r lig
htin
g, d
omes
tic h
ot w
ater
hea
ting
and
all r
enew
able
ene
rgy
syst
ems c
ompl
ete
with
a d
escr
iptio
n of
how
thes
e sy
stem
s con
nect
to, a
nd a
re c
ontr
olle
d in
con
junc
tion
with
, the
ove
rall
build
ing
syst
em.
Syst
em B
alan
cing
Rep
ort:
A w
ritte
n re
port
des
crib
ing
the
activ
ities
and
mea
sure
men
ts c
ompl
eted
in a
ccor
danc
e w
ith IG
CCSe
ctio
n 61
1.1.
2 sh
all b
e pr
ovid
ed.
Fina
l Com
mis
sion
ing
Repo
rt: A
com
plet
e re
port
of t
est p
roce
dure
s and
resu
lts id
entif
ied
as "F
inal
Com
miss
ioni
ng R
epor
t” sh
all
be c
ompl
eted
and
pro
vide
d to
the
build
ing
owne
r. Th
e re
port
shal
l inc
lude
all
of th
e fo
llow
ing:
1. R
esul
ts o
f all
func
tiona
l per
form
ance
test
s.2.
Disp
ositi
on o
f all
defic
ienc
ies f
ound
dur
ing
test
ing,
incl
udin
g de
tails
of c
orre
ctiv
e m
easu
res u
sed
or p
ropo
sed.
3. A
ll fu
nctio
nal p
erfo
rman
ce te
st p
roce
dure
s use
d du
ring
the
com
miss
ioni
ng p
roce
ss in
clud
ing
mea
sura
ble
crite
ria fo
r tes
tac
cept
ance
, pro
vide
d he
rein
for r
epea
tabi
lity.
Exce
ptio
n: D
efer
red
test
s tha
t wer
e no
t per
form
ed a
t the
tim
e of
repo
rt p
repa
ratio
n be
caus
e of
clim
atic
con
ditio
ns.
Post
-Occ
upan
cy R
ecom
mis
sion
ing:
The
com
miss
ioni
ng a
ctiv
ities
spec
ified
in IG
CC S
ectio
ns 6
11.1
.2 th
roug
h 61
1.1.
5 sh
all b
ere
peat
ed 1
8 to
24
mon
ths a
fter
cer
tific
ate
of o
ccup
ancy
. The
GC
shal
l ini
tiate
such
act
iviti
es b
y sc
hedu
ling
all n
eces
sary
test
ing
and
mee
tings
with
the
Ow
ner a
nd C
omm
issio
ning
Age
nt. S
yste
ms a
nd c
ontr
ol d
evic
es th
at a
re n
ot fu
nctio
ning
pro
perly
shal
lbe
repa
ired
or re
plac
ed b
y GC
, at n
o co
st to
bui
ldin
g O
wne
r. Ad
just
men
ts to
cal
ibra
tion
sett
ings
shal
l be
docu
men
ted.
Thi
sdo
cum
enta
tion
shal
l be
prov
ided
to th
e bu
ildin
g ow
ner a
nd C
omm
issio
ning
Age
nt.
Sequ
ence
of O
pera
tion:
A se
quen
ce o
f ope
ratio
n sh
all b
e de
velo
ped
and
final
ized
by th
e GC
upo
n co
mm
issio
ning
, whe
n th
eop
erat
iona
l det
ails
are
initi
alize
d an
d va
lidat
ed. A
sequ
ence
of o
pera
tion
shal
l be
the
final
reco
rd o
f sys
tem
ope
ratio
n, a
ndsh
all b
e in
clud
ed o
n th
e co
ntro
l dia
gram
"as-
built
s,”
or a
s par
t of t
he e
duca
tion
and
oper
atio
n an
d m
aint
enan
ce d
ocum
ent
that
is p
rovi
ded
to th
e ow
ner.
Ligh
ting
and
elec
tric
al sy
stem
s com
mis
sion
ing
and
com
plet
ion
requ
irem
ents
: Prio
r to
issua
nce
of a
cer
tific
ate
of o
ccup
ancy
,th
e Co
mm
issio
ning
Age
nt sh
all p
rovi
de e
vide
nce
of li
ghtin
g an
d el
ectr
ical
syst
ems c
omm
issio
ning
and
com
plet
ion
inac
cord
ance
with
the
Inte
rnat
iona
l Ene
rgy
Cons
erva
tion
Code
and
the
prov
ision
s of t
his s
ectio
n.
Draw
ing
note
s sha
ll sp
ecify
the
prov
ision
s for
com
miss
ioni
ng a
nd c
ompl
etio
n re
quire
men
ts in
acc
orda
nce
with
this
sect
ion
and
are
perm
itted
to re
fer t
o sp
ecifi
catio
ns fo
r fur
ther
requ
irem
ents
. Cop
ies o
f all
docu
men
tatio
n sh
all b
e gi
ven,
by
the
GC, t
o th
eow
ner a
nd m
ade
avai
labl
e to
the
code
offi
cial u
pon
requ
est i
n ac
cord
ance
with
IGCC
Sec
tions
611
.2.4
and
611
.2.5
Prec
onst
ruct
ion
docu
men
tatio
n, li
ghtin
g: C
onst
ruct
ion
and
owne
r edu
catio
n do
cum
ents
shal
l inc
lude
floo
r pla
ns, d
iagr
ams
and
nota
tions
of s
uffic
ient
cla
rity
desc
ribin
g th
e ty
pes o
f, lo
catio
n an
d op
erat
iona
l req
uire
men
ts o
f all
light
ing
cont
rols
incl
udin
g a
sequ
ence
of o
pera
tion
and
prel
imin
ary
inte
nded
setp
oint
s for
all
dim
min
g sy
stem
s and
aut
omat
ic d
aylig
ht co
ntro
ls,de
mon
stra
ting
conf
orm
ance
to th
e pr
ovisi
ons o
f thi
s cod
e, re
leva
nt la
ws,
ord
inan
ces,
rule
s and
regu
latio
ns, a
s ap
prov
ed b
y th
eco
de o
fficia
l.
Verif
icat
ion:
The
app
rove
d ag
ency
con
duct
ing
com
miss
ioni
ng sh
all v
erify
that
con
trol
s hav
e be
en in
stal
led
in a
ccor
danc
e w
ithth
e ap
prov
ed c
onst
ruct
ion
docu
men
ts. A
ny d
iscre
panc
ies s
hall
be re
view
ed fo
r com
plia
nce
with
Sec
tion
608
and
the
requ
irem
ents
of S
ectio
n C4
05.2
of t
he In
tern
atio
nal E
nerg
y Co
nser
vatio
n Co
de.
Ligh
ting
Cont
rols
Com
mis
sion
ing:
Occ
upan
t sen
sors
: Ver
ifica
tion
that
the
func
tiona
l tes
ting
of o
ccup
ant s
enso
rs h
as b
een
perf
orm
ed, i
n ac
cord
ance
with
Sec
tion
C405
.2 o
f the
Inte
rnat
iona
l Ene
rgy
Cons
erva
tion
Code
, sha
ll be
con
duct
ed.
Auto
mat
ic d
aylig
ht c
ontr
ols:
Aut
omat
ic d
aylig
ht co
ntro
ls sh
all b
e co
mm
issio
ned
in a
ccor
danc
e w
ith a
ll of
the
follo
win
g:1.
It sh
all b
e ve
rifie
d th
at th
e pl
acem
ent a
nd o
rient
atio
n of
eac
h se
nsor
is c
onsis
tent
with
the
man
ufac
ture
r's in
stru
ctio
ns. I
fno
t, th
e se
nsor
shal
l be
relo
cate
d or
repl
aced
.2.
Con
trol
syst
ems s
hall
be in
itial
ly c
alib
rate
d to
mee
t set
tings
and
des
ign
inte
nt e
stab
lishe
d in
the
cons
truc
tion
docu
men
ts.
3. P
rior t
o ca
libra
tion
of sy
stem
s con
trol
ling
dim
mab
le lu
min
aire
s, a
ll la
mps
shal
l be
seas
oned
in a
ccor
danc
e w
ith th
ere
com
men
datio
ns o
f the
lam
p m
anuf
actu
rer.
4. W
here
loca
ted
insid
e bu
ildin
gs, c
alib
ratio
n of
ope
n-lo
op d
aylig
ht co
ntro
ls, w
hich
rece
ive
illum
inat
ion
from
nat
ural
ligh
t onl
y,sh
all n
ot o
ccur
unt
il fe
nest
ratio
n sh
adin
g de
vice
s suc
h as
blin
ds o
r sha
des h
ave
been
inst
alle
d an
d co
mm
issio
ned.
5. C
alib
ratio
n of
clo
sed-
loop
day
light
cont
rols,
that
rece
ive
illum
inat
ion
from
bot
h na
tura
l and
art
ifici
al li
ght,
shal
l not
occ
ur u
ntil
furn
iture
syst
ems a
nd in
terio
r fin
ishes
hav
e be
en in
stal
led,
and
any
fene
stra
tion
shad
ing
devi
ces s
uch
as b
linds
or s
hade
s hav
ebe
en in
stal
led
and
com
miss
ione
d.6.
Cal
ibra
tion
proc
edur
es sh
all b
e in
acc
orda
nce
with
the
man
ufac
ture
r's in
stru
ctio
ns.
The
tota
l lig
htin
g in
the
elev
ator
cab
shal
l be
not l
ess t
han
35 lu
men
s per
wat
t, ba
sed
on th
e to
tal l
umen
s fro
m la
mps
div
ided
by
the
tota
l wat
tage
of t
he lu
min
aire
s in
the
cab,
but
not
incl
udin
g lu
min
aire
s of s
igna
ls an
d di
spla
ys.
Indu
ctio
n m
otor
with
a C
lass
IE2
effic
ienc
y ra
ting,
as d
efin
ed b
y IE
C EN
600
34-3
0, o
r alte
rnat
ive
tech
nolo
gies
, suc
h as
perm
anen
t mag
net s
ynch
rono
us m
otor
s tha
t hav
e eq
ual o
r bet
ter e
ffici
ency
, sha
ll be
use
d fo
r the
ele
vato
r. Tr
ansm
issio
ns sh
all
not r
educ
e th
e ef
ficie
ncy
of th
e co
mbi
ned
mot
or/t
rans
miss
ion
belo
w th
at sh
own
for t
he C
lass
IE2
mot
or. G
earle
ss m
achi
nes
shal
l be
assu
med
to h
ave
a 10
0-pe
rcen
t tra
nsm
issio
n ef
ficie
ncy.
Pot
entia
l ene
rgy
rele
ased
dur
ing
mot
ion
shal
l be
reco
vere
d.Th
e bu
ildin
g sh
all b
e eq
uipp
ed w
ith a
sola
r pho
tovo
ltaic
rene
wab
le e
nerg
y sy
stem
that
has
the
capa
city
to p
rovi
de n
ot le
ss th
an10
per
cent
of t
he to
tal c
alcu
late
d an
nual
ene
rgy
use
of th
e bu
ildin
gs a
s det
erm
ined
by
the
mec
hani
cal e
ngin
eer.
The
phot
ovol
taic
syst
em sh
all b
e De
sign-
Build
by
the
GC u
sing
a co
mpe
tent
des
ign
engi
neer
spec
ializ
ed in
pho
tovo
ltaic
syst
ems.
The
inst
alla
tion,
insp
ectio
n, m
aint
enan
ce, r
epai
r and
repl
acem
ent o
f sol
ar p
hoto
volta
ic sy
stem
s and
syst
em c
ompo
nent
s sha
llco
mpl
y w
ith th
e m
anuf
actu
rer's
inst
ruct
ions
, IGC
C Se
ctio
n 61
0.2.
2.1,
the
Inte
rnat
iona
l Fire
Cod
e, th
e In
tern
atio
nal B
uild
ing
Code
and
NFP
A 70
.So
lar p
hoto
volta
ic sy
stem
s sha
ll be
test
ed o
n in
stal
latio
n to
ver
ify th
at th
e in
stal
led
perf
orm
ance
mee
ts th
e de
sign
spec
ifica
tions
. A re
port
of t
he te
sted
per
form
ance
shal
l be
prov
ided
to th
e bu
ildin
g ow
ner a
nd C
omm
issio
ning
Age
nt.
The
PV sy
stem
shal
l be
met
ered
and
mon
itore
d in
acc
orda
nce
with
IGCC
Sec
tions
610
.5.1
and
610
.5.2
and
sha
ll be
mon
itore
dto
mea
sure
the
peak
ele
ctric
or t
herm
al e
nerg
y ge
nera
ted
durin
g th
e bu
ildin
g's a
ntic
ipat
ed p
eak
elec
tric
or f
ossil
fuel
cons
umpt
ion
perio
d in
acc
orda
nce
with
IGCC
Sec
tion
603.
ENER
GY S
YSTE
MS
COM
MIS
SIO
NIN
G AN
D CO
MPL
ETIO
NW
ithin
20
days
from
app
rova
l con
duct
ing
the
final
mec
hani
cal i
nspe
ctio
n th
e GC
shal
l pro
vide
the
Ow
ner a
nd th
eCo
mm
issio
ning
Age
nt a
ll m
echa
nica
l sys
tem
doc
umen
tatio
n, m
anua
ls, te
stin
g an
d ba
lanc
ing
repo
rts,
and
a re
port
of a
llva
riatio
n an
d fie
ld c
hang
es fo
rm th
e or
igin
al c
onst
ruct
ion
docu
men
ts. T
he G
C sh
all s
ched
ule
a co
nven
ient
tim
e to
mee
t on
site
with
the
Com
miss
ion
Agen
t and
to p
erfo
rm a
ny a
dditi
onal
test
requ
este
d by
Com
miss
ioni
ng A
gent
as n
eces
sary
for t
heco
mpl
etin
g th
e Co
mm
issio
ning
Cer
tific
atio
n.W
ithin
60
days
from
app
rova
l con
duct
ing
the
final
mec
hani
cal i
nspe
ctio
n, th
e Co
mm
issio
ning
Age
nt sh
all p
rovi
de e
vide
nce
ofm
echa
nica
l sys
tem
s com
miss
ioni
ng a
nd c
ompl
etio
n of
the
mec
hani
cal s
yste
m in
stal
latio
n to
the
code
offi
cial,
in a
ccor
danc
ew
ith th
e In
tern
atio
nal E
nerg
y Co
nser
vatio
n Co
de.
Draw
ing
note
s sha
ll cl
early
indi
cate
pro
visio
ns fo
r com
miss
ioni
ng a
nd c
ompl
etio
n re
quire
men
ts in
acc
orda
nce
with
this
sect
ion
and
are
perm
itted
to re
fer t
o sp
ecifi
catio
ns fo
r fur
ther
requ
irem
ents
. Cop
ies o
f all
docu
men
tatio
n sh
all b
e gi
ven
to th
e ow
ner
and
mad
e av
aila
ble
to th
e co
de o
fficia
l upo
n re
ques
t.A
com
miss
ioni
ng p
lan
shal
l be
deve
lope
d by
the
Com
miss
ioni
ng A
gent
and
shal
l inc
lude
as a
min
imum
all
of th
e fo
llow
ing
item
s:1.
A n
arra
tive
desc
ribin
g th
e ac
tiviti
es th
at w
ill b
e ac
com
plish
ed d
urin
g ea
ch p
hase
of c
omm
issio
ning
, inc
ludi
ng g
uida
nce
onw
ho a
ccom
plish
es th
e ac
tiviti
es a
nd h
ow th
ey a
re c
ompl
eted
.2.
Equ
ipm
ent a
nd sy
stem
s to
be te
sted
incl
udin
g, b
ut n
ot li
mite
d to
, the
spec
ific
equi
pmen
t, ap
plia
nces
or s
yste
ms t
o be
test
edan
d th
e nu
mbe
r and
ext
ent o
f tes
ts.
3. F
unct
ions
to b
e te
sted
incl
udin
g, b
ut n
ot li
mite
d to
, cal
ibra
tions
and
eco
nom
izer c
ontr
ols.
4. C
ondi
tions
und
er w
hich
the
test
shal
l be
perf
orm
ed in
clud
ing,
but
not
lim
ited
to, a
ffirm
atio
n of
win
ter a
nd su
mm
er d
esig
nco
nditi
ons a
nd fu
ll ou
tsid
e ai
r.5.
Mea
sura
ble
crite
ria fo
r per
form
ance
.Th
e GC
shal
l cau
se th
e HV
AC sy
stem
s to
be b
alan
ced
in a
ccor
danc
e w
ith g
ener
ally
acc
epte
d en
gine
erin
g st
anda
rds.
Air
and
wat
er fl
ow ra
tes s
hall
be m
easu
red
and
adju
sted
to d
eliv
er fi
nal f
low
rate
s with
in th
e to
lera
nces
pro
vide
d in
the
prod
uct
spec
ifica
tions
. Tes
t and
bal
ance
act
iviti
es sh
all i
nclu
de, a
t a m
inim
um, t
he p
rovi
sions
of I
GCC
Sect
ions
611
.1.2
.1 a
nd 6
11.1
.2.2
.Ea
ch su
pply
air
outle
t and
zone
term
inal
dev
ice
shal
l be
equi
pped
with
a m
eans
for a
ir ba
lanc
ing
in a
ccor
danc
e w
ith th
eIn
tern
atio
nal M
echa
nica
l Cod
e. D
ischa
rge
dam
pers
are
pro
hibi
ted
on c
onst
ant v
olum
e fa
ns a
nd v
aria
ble
volu
me
fans
with
mot
ors o
f 10
hp a
nd la
rger
. Air
syst
ems s
hall
be b
alan
ced
in a
man
ner t
o fir
st m
inim
ize th
rott
ling
loss
es th
en, f
or fa
ns w
ithsy
stem
pow
er o
f gre
ater
than
1 h
p, fa
n sp
eed
shal
l be
adju
sted
to m
eet d
esig
n flo
w c
ondi
tions
.Fu
nctio
nal p
erfo
rman
ce te
stin
g sh
all b
e in
acc
orda
nce
with
the
requ
irem
ents
of I
GCC
Sect
ions
611
.1.3
.1, 6
11.1
.3.2
and
611.
1.3.
3.Eq
uipm
ent:
Equi
pmen
t fun
ctio
nal p
erfo
rman
ce te
stin
g sh
all d
emon
stra
te th
e in
stal
latio
n an
d op
erat
ion
of c
ompo
nent
s,sy
stem
s, a
nd sy
stem
-to-
syst
em in
terf
acin
g re
latio
nshi
ps in
acc
orda
nce
with
app
rove
d pl
ans a
nd sp
ecifi
catio
ns so
that
oper
atio
n, fu
nctio
n, a
nd m
aint
enan
ce se
rvic
eabi
lity
for e
ach
of th
e co
mm
issio
ned
syst
ems i
s con
firm
ed. T
estin
g sh
all i
nclu
de a
llsp
ecifi
ed m
odes
of c
ontr
ol a
nd se
quen
ce o
f ope
ratio
n, in
clud
ing
unde
r ful
l-loa
d, p
art-
load
and
all
of th
e fo
llow
ing
emer
genc
yco
nditi
ons:
1. E
ach
mod
e as
des
crib
ed in
the
sequ
ence
of o
pera
tion.
2. R
edun
dant
or a
utom
atic
bac
kup
mod
e.3.
Per
form
ance
of a
larm
s.4.
Mod
e of
ope
ratio
n up
on a
loss
of p
ower
and
rest
orat
ion
of p
ower
Cont
rols
: HVA
C co
ntro
l sys
tem
s sha
ll be
test
ed to
doc
umen
t tha
t con
trol
dev
ices
, com
pone
nts,
equ
ipm
ent,
and
syst
ems a
reca
libra
ted,
adj
uste
d an
d op
erat
ed in
acc
orda
nce
with
the
appr
oved
pla
ns a
nd sp
ecifi
catio
ns. S
eque
nces
of o
pera
tion
shal
l be
func
tiona
lly te
sted
to d
ocum
ent t
hat t
hey
oper
ate
in a
ccor
danc
e w
ith th
e ap
prov
ed p
lans
and
spec
ifica
tions
.Ec
onom
izer
s: A
ir ec
onom
izers
shal
l und
ergo
a fu
nctio
nal t
est t
o de
term
ine
that
they
ope
rate
in a
ccor
danc
e w
ith th
em
anuf
actu
rer's
spec
ifica
tions
.
A pr
elim
inar
y re
port
of c
omm
issio
ning
test
pro
cedu
res a
nd re
sults
shal
l be
com
plet
ed a
nd c
ertif
ied
by th
e Co
mm
issio
ning
Agen
t and
pro
vide
d to
the
GC a
nd b
uild
ing
owne
r. Th
e re
port
shal
l be
iden
tifie
d as
"Pre
limin
ary
Com
miss
ioni
ng R
epor
t” a
ndsh
all i
dent
ify a
ll of
the
follo
win
g:1.
Item
izatio
n of
def
icie
ncie
s fou
nd d
urin
g te
stin
g re
quire
d by
this
sect
ion
that
hav
e no
t bee
n co
rrec
ted
at th
e tim
e of
repo
rtpr
epar
atio
n.2.
Def
erre
d te
sts t
hat c
anno
t be
perf
orm
ed a
t the
tim
e of
repo
rt p
repa
ratio
n be
caus
e of
clim
atic
con
ditio
ns.
3. C
limat
ic c
ondi
tions
requ
ired
for p
erfo
rman
ce o
f the
def
erre
d te
sts.
Build
ings
, or p
ortio
ns th
ereo
f, sh
all n
ot p
ass t
he fi
nal m
echa
nica
l ins
pect
ion
until
such
tim
e as
the
code
offi
cial h
as re
ceiv
ed a
lett
er o
f tra
nsm
ittal
from
the
GC a
ckno
wle
dgin
g th
at th
e bu
ildin
g ow
ner h
as re
ceiv
ed th
e Pr
elim
inar
y Co
mm
issio
ning
Rep
ort.
At th
e re
ques
t of t
he co
de o
fficia
l, a
copy
of t
he P
relim
inar
y Co
mm
issio
ning
Rep
ort s
hall
be m
ade
avai
labl
e fo
r rev
iew
.
Tim
e sw
itch
and
prog
ram
mab
le sc
hedu
le c
ontr
ols:
Lig
htin
g co
ntro
ls in
stal
led
in a
ccor
danc
e w
ith IG
CC S
ectio
n 60
8 sh
all b
epr
ogra
mm
ed. S
ched
ulin
g sh
all i
ncor
pora
te w
eekd
ay, w
eeke
nd a
nd h
olid
ay o
pera
ting
times
, inc
ludi
ng le
ap y
ear a
nd d
aylig
htsa
ving
s tim
e co
rrec
tions
. It s
hall
be v
erifi
ed th
at sy
stem
ove
rrid
es w
ork
and
are
loca
ted
in c
ompl
ianc
e w
ith S
ectio
n C4
05.2
of
the
Inte
rnat
iona
l Ene
rgy
Cons
erva
tion
Code
.
Dim
min
g sy
stem
s with
pre
set s
cene
s: F
or p
rogr
amm
able
dim
min
g sy
stem
s, it
shal
l be
verif
ied
that
aut
omat
ic sh
utof
f and
man
ual o
verr
ides
are
wor
king
and
that
pro
gram
min
g is
com
plet
e. P
rior t
o pr
ogra
mm
ing,
all
lam
ps sh
all b
e se
ason
ed in
acco
rdan
ce w
ith N
EMA
LSD
23.
Post
-com
mis
sion
ing
docu
men
tatio
n: T
he fo
llow
ing
docu
men
tatio
n sh
all b
e pr
ovid
ed b
y th
e GC
to th
e bu
ildin
g ow
ner i
nac
cord
ance
with
Sec
tion
903.
1. S
ettin
gs d
eter
min
ed d
urin
g co
mm
issio
ning
act
iviti
es o
utlin
ed in
Sec
tion
611.
3.3.
2. A
nar
rativ
e de
scrib
ing
the
inte
nt a
nd fu
nctio
nalit
y of
all
cont
rols
incl
udin
g an
y ca
pabi
lity
for u
sers
to o
verr
ide
a sc
hedu
le o
rm
aste
r com
man
d.3.
Spe
cific
atio
n sh
eets
for a
ll lig
htin
g eq
uipm
ent a
nd c
ontr
ols.
4. O
pera
tion
man
uals
for e
ach
light
ing
cont
rol d
evic
e. R
equi
red
mai
nten
ance
and
mai
nten
ance
sche
dule
s sha
ll be
cle
arly
iden
tifie
d. D
ocum
enta
tion
and
inst
ruct
ions
nec
essa
ry fo
r bui
ldin
g m
aint
enan
ce p
erso
nnel
to m
aint
ain
and
reca
libra
te li
ghtin
gsy
stem
s and
con
trol
s.5.
An
annu
al in
spec
tion
sche
dule
for l
ight
ing
cont
rols.
6. T
roub
lesh
ootin
g in
form
atio
n fo
r flu
ores
cent
dim
min
g sy
stem
s and
the
rem
edia
tion
of sw
itchi
ng is
sues
such
as f
alse
-ons
and
false
-offs
.
Post
-occ
upan
cy R
ecom
mis
sion
ing:
The
com
miss
ioni
ng a
ctiv
ities
in S
ectio
n 61
1.3.
3 sh
all b
e re
peat
ed 1
8 to
24
mon
ths a
fter
issua
nce
of th
e ce
rtifi
cate
of o
ccup
ancy
. The
GC
shal
l ini
tiate
such
act
iviti
es b
y sc
hedu
ling
all n
eces
sary
test
ing
and
mee
tings
with
the
Ow
ner a
nd C
omm
issio
ning
Age
nt. C
ontr
ol d
evic
es th
at a
re n
ot fu
nctio
ning
pro
perly
shal
l be
repa
ired
or re
plac
ed b
yth
e GC
at n
o co
st to
Ow
ner.
Adju
stm
ents
to c
alib
ratio
n se
ttin
gs sh
all b
e do
cum
ente
d. T
his d
ocum
enta
tion
shal
l be
prov
ided
toth
e bu
ildin
g ow
ner a
nd C
omm
issio
ning
Age
nt.
Build
ing
enve
lope
syst
ems c
omm
issi
onin
g an
d co
mpl
etio
n re
quire
men
ts: P
rior t
o iss
uanc
e of
a c
ertif
icat
e of
occ
upan
cy, t
heCo
mm
issio
ning
Age
nt sh
all p
rovi
de e
vide
nce
of b
uild
ing
ther
mal
env
elop
e sy
stem
s com
miss
ioni
ng a
nd c
ompl
etio
n to
the
build
ing
owne
r in
acco
rdan
ce w
ith th
e In
tern
atio
nal E
nerg
y Co
nser
vatio
n Co
de a
nd th
e pr
ovisi
ons o
f thi
s sec
tion.
Cons
truc
tion
docu
men
ts sh
all s
peci
fy th
e pr
ovisi
ons f
or c
omm
issio
ning
and
com
plet
ion
requ
irem
ents
in a
ccor
danc
e w
ith th
isse
ctio
n an
d ar
e pe
rmitt
ed to
refe
r to
spec
ifica
tions
for f
urth
er re
quire
men
ts. C
opie
s of a
ll do
cum
enta
tion
shal
l be
give
n, b
y G
C,to
the
build
ing
owne
r and
mad
e av
aila
ble
to th
e co
de o
fficia
l upo
n re
ques
t in
acco
rdan
ce w
ith IG
CC S
ectio
ns 6
11.4
.1 a
nd61
1.4.
2.
Prec
onst
ruct
ion
docu
men
tatio
n, b
uild
ing
ther
mal
env
elop
e: C
onst
ruct
ion
and
owne
r edu
catio
n do
cum
ents
shal
l ind
icat
e th
elo
catio
n, n
atur
e an
d ex
tent
of t
he w
ork
prop
osed
and
show
the
func
tiona
l req
uire
men
ts a
nd o
pera
tion
of a
ll bu
ildin
g th
erm
alen
velo
pe sy
stem
s dem
onst
ratin
g co
nfor
man
ce to
the
prov
ision
s of t
his c
ode,
rele
vant
law
s, o
rdin
ance
s, ru
les a
nd re
gula
tions
,as
app
rove
d by
the
code
offi
cial.
Verif
icat
ion:
The
app
rove
d ag
ency
con
duct
ing
com
miss
ioni
ng sh
all v
erify
that
bui
ldin
g th
erm
al e
nvel
ope
syst
ems h
ave
been
inst
alle
d in
acc
orda
nce
with
the
appr
oved
con
stru
ctio
n do
cum
ents
. Any
disc
repa
ncie
s sha
ll be
revi
ewed
for c
ompl
ianc
e w
ithre
quire
men
ts o
f the
Inte
rnat
iona
l Ene
rgy
Cons
erva
tion
Code
and
this
code
.
INDO
OR
ENVI
RON
MEN
TAL
QU
ALIT
Y AN
D CO
NFO
RT
Indo
or a
ir qu
ality
man
agem
ent p
lan
requ
ired:
An
indo
or a
ir qu
ality
man
agem
ent p
lan
shal
l be
deve
lope
d by
the
GC. S
uch
plan
shal
l add
ress
the
met
hods
and
pro
cedu
res t
o be
use
d du
ring
desig
n an
d co
nstr
uctio
n to
obt
ain
com
plia
nce
with
Sec
tions
802
thro
ugh
805.
Cons
truc
tion
phas
e re
quire
men
ts: T
he v
entil
atio
n of
bui
ldin
gs d
urin
g th
e co
nstr
uctio
n ph
ase
shal
l be
in a
ccor
danc
e w
ith IG
CCSe
ctio
ns 8
03.1
.1 th
roug
h 80
3.1.
3.Du
ct o
peni
ngs:
Duc
t and
oth
er re
late
d ai
r dist
ribut
ion
com
pone
nt o
peni
ngs s
hall
be c
over
ed w
ith ta
pe, p
last
ic, s
heet
met
al o
rsh
all b
e cl
osed
by
an a
ppro
ved
met
hod
to re
duce
the
amou
nt o
f dus
t and
deb
ris th
at c
olle
cts i
n th
e sy
stem
from
the
time
ofro
ugh-
in in
stal
latio
n an
d un
til st
artu
p of
the
heat
ing
and
cool
ing
equi
pmen
t. Du
st a
nd d
ebris
shal
l be
clea
ned
from
duc
top
enin
gs p
rior t
o sy
stem
flus
h ou
t and
bui
ldin
g oc
cupa
ncy.
Indo
or a
ir qu
ality
dur
ing
cons
truc
tion:
Tem
pora
ry v
entil
atio
n du
ring
cons
truc
tion
shal
l be
prov
ided
in a
ccor
danc
e w
ith IG
CCSe
ctio
ns 8
03.1
.2.1
thro
ugh
803.
1.2.
3.Ve
ntila
tion:
Ven
tilat
ion
durin
g co
nstr
uctio
n sh
all b
e ac
hiev
ed th
roug
h op
enin
gs in
the
build
ing
enve
lope
usin
g on
e or
mor
e of
the
follo
win
g m
etho
ds:
1. N
atur
al v
entil
atio
n in
acc
orda
nce
with
the
prov
ision
s of t
he In
tern
atio
nal B
uild
ing
Code
or t
he In
tern
atio
nal M
echa
nica
l Cod
e.2.
Fan
s tha
t pro
duce
a m
inim
um o
f thr
ee a
ir ch
ange
s per
hou
r.3.
Exh
aust
in th
e w
ork
area
at a
rate
of n
ot le
ss th
an 0
.05
cfm
/ft2
(0.2
4 L/
s/in
2) a
nd n
ot le
ss th
an 1
0 pe
rcen
t gre
ater
than
the
supp
ly a
ir ra
te so
as t
o m
aint
ain
nega
tive
pres
suriz
atio
n of
the
spac
e.
Prot
ectio
n of
HVA
C sy
stem
ope
ning
s: H
VAC
supp
ly a
nd re
turn
duc
t and
equ
ipm
ent o
peni
ngs s
hall
be p
rote
cted
dur
ing
dust
-pro
duci
ng o
pera
tions
.Re
turn
air
filte
rs.
Whe
re a
forc
ed a
ir HV
AC sy
stem
is u
sed
durin
g co
nstr
uctio
n, n
ew re
turn
air
filte
rs sh
all b
e in
stal
led
prio
r to
syst
em fl
ush
out
and
build
ing
occu
panc
y.Co
nstr
uctio
n ph
ase
duct
less
syst
em o
r filt
er: W
here
spac
es a
re c
ondi
tione
d du
ring
the
cons
truc
tion
phas
e, sp
ace
cond
ition
ing
syst
ems s
hall
be o
f the
duc
tless
var
iety
, or f
ilter
s for
duc
ted
syst
ems s
hall
be ra
ted
at M
ERV
8 or
hig
her i
n ac
cord
ance
with
ASHR
AE 5
2.2,
and
syst
em e
quip
men
t sha
ll be
des
igne
d to
be
com
patib
le. D
uct s
yste
m d
esig
n sh
all a
ccou
nt fo
r pre
ssur
e dr
opac
ross
the
filte
r.Th
erm
al e
nviro
nmen
tal c
ondi
tions
for h
uman
occ
upan
cy: B
uild
ings
shal
l be
desig
ned
in c
ompl
ianc
e w
ith A
SHRA
E 55
, Sec
tions
6.1,
"Des
ign,
” an
d 6.
2, "D
ocum
enta
tion.
”En
viro
nmen
tal t
obac
co sm
oke
cont
rol:
Smok
ing
shal
l not
be
allo
wed
insid
e of
bui
ldin
gs. A
ny e
xter
ior d
esig
nate
d sm
okin
g ar
eas
shal
l be
loca
ted
not l
ess t
han
25 ft
aw
ay fr
om b
uild
ing
entr
ance
s, o
utdo
or a
ir in
take
s, a
nd o
pera
ble
win
dow
s.Is
olat
ion
of p
ollu
tant
sour
ces:
The
isol
atio
n of
pol
luta
nt so
urce
s rel
ated
to p
rint,
copy
and
jani
toria
l roo
ms,
gar
ages
and
hang
ars s
hall
be in
acc
orda
nce
with
Sec
tion
803.
4.1.
Prin
ter,
copi
er a
nd ja
nito
rial r
oom
s: E
nclo
sed
room
s or s
pace
s tha
t are
ove
r 100
squa
re fe
et (9
.3 m
2) in
are
a an
d th
at a
re u
sed
prim
arily
as a
prin
t or c
opy
faci
lity
cont
aini
ng fi
ve o
r mor
e pr
inte
rs, c
opy
mac
hine
s, sc
anne
rs, f
acsim
ile m
achi
nes o
r sim
ilar
mac
hine
s in
any
com
bina
tion,
and
room
s use
d pr
imar
ily a
s jan
itoria
l roo
ms o
r clo
sets
whe
re th
e us
e or
stor
age
of c
hem
ical
soc
curs
, sha
ll co
mpl
y w
ith a
ll of
the
follo
win
g:1.
The
enc
losin
g w
alls
shal
l ext
end
from
the
floor
surf
ace
to th
e un
ders
ide
of th
e flo
or, r
oof d
eck
or so
lid c
eilin
g ab
ove
and
shal
lbe
con
stru
cted
to re
sist t
he p
assa
ge o
f airb
orne
che
mic
al p
ollu
tant
s and
shal
l be
cons
truc
ted
and
seal
ed a
s req
uire
d fo
r 1-h
our
fire-
resis
tanc
e-ra
ted
cons
truc
tion
asse
mbl
ies.
Alte
rnat
ivel
y, fo
r jan
itoria
l roo
ms a
nd c
lose
ts, a
ll ch
emic
als s
hall
be st
ored
inap
prov
ed c
hem
ical
safe
ty st
orag
e ca
bine
ts.
2. D
oors
in th
e en
clos
ing
wal
ls sh
all b
e au
tom
atic
or s
elf-c
losin
g.3.
An
HVAC
syst
em sh
all b
e pr
ovid
ed th
at: p
rovi
des s
epar
ate
exha
ust a
irflo
w to
the
outd
oors
at a
rate
of n
ot le
ss th
an 0
.50
cfm
per s
quar
e fo
ot (2
.4 L
/s/m
2); t
hat m
aint
ains
a n
egat
ive
pres
sure
of n
ot le
ss th
an 7
Pa
with
in th
e ro
om; a
nd th
at p
rohi
bits
the
reci
rcul
atio
n of
air
from
the
room
to o
ther
por
tions
of t
he b
uild
ing.
Filte
rs: F
ilter
s for
air-
cond
ition
ing
syst
ems t
hat s
erve
occ
upie
d sp
aces
shal
l be
rate
d at
MER
V 11
or h
ighe
r, in
acc
orda
nce
with
ASHR
AE S
tand
ard
52.2
, and
syst
em e
quip
men
t sha
ll be
des
igne
d to
be
com
patib
le. T
he a
ir-ha
ndlin
g sy
stem
des
ign
shal
l acc
ount
for p
ress
ure
drop
acr
oss t
he fi
lter.
The
pres
sure
dro
p ac
ross
cle
an M
ERV
11 fi
lters
shal
l be
not g
reat
er th
an 0
.45
in. w
.c. a
t 500
FPM
(412
Pa
at 2
.54
m/s
) filt
er fa
ce v
eloc
ity. F
ilter
per
form
ance
shal
l be
show
n on
the
filte
r man
ufac
ture
r's d
ata
shee
t.
PRO
HIBI
TED
MAT
ERIA
LSTh
e us
e of
the
follo
win
g m
ater
ials
shal
l be
proh
ibite
d:1.
Asb
esto
s-co
ntai
ning
mat
eria
ls.2.
Ure
a-fo
rmal
dehy
de fo
am in
sula
tion
GC sh
all v
erify
, prio
r to
orde
ring,
that
all
mat
eria
ls sp
ecifi
ed a
nd/o
r to
be in
corp
orat
ed in
to th
e pr
ojec
t mee
t the
Mat
eria
lEm
issi
on a
nd P
ollu
tant
Con
trol
requ
irem
ents
spec
ified
in C
hapt
er 8
of t
he 2
012
IGCC
.Em
issi
ons f
rom
com
posi
te w
ood
prod
ucts
: Com
posit
e w
ood
prod
ucts
use
d in
terio
r to
the
appr
oved
wea
ther
cov
erin
g of
the
build
ing
shal
l com
ply
with
the
emiss
ion
limits
or b
e m
anuf
actu
red
in a
ccor
danc
e w
ith th
e st
anda
rds c
ited
in IG
CC T
able
806
.1.
Com
plia
nce
with
em
issio
n lim
its sh
all b
e de
mon
stra
ted
follo
win
g th
e re
quire
men
ts o
f Sec
tion
9312
0 of
Titl
e 17
, Cal
iforn
ia C
ode
of R
egul
atio
ns, A
irbor
ne T
oxic
Cont
rol M
easu
re to
Red
uce
Form
alde
hyde
Em
issio
ns fr
om C
ompo
site
Woo
d Pr
oduc
ts.
Exce
ptio
ns:
1. C
ompo
site
woo
d pr
oduc
ts th
at a
re m
ade
usin
g ad
hesiv
es th
at d
o no
t con
tain
ure
a-fo
rmal
dehy
de (U
F) re
sins.
2. C
ompo
site
woo
d pr
oduc
ts th
at a
re se
aled
with
an
impe
rmea
ble
mat
eria
l on
all s
ides
and
edg
es.
3. C
ompo
site
woo
d pr
oduc
ts th
at a
re u
sed
to m
ake
elem
ents
con
sider
ed to
be
furn
iture
, fix
ture
s and
equ
ipm
ent (
FF&
E) th
atar
e no
t per
man
ently
inst
alle
d.Ad
hesi
ves a
nd se
alan
ts.
A m
inim
um o
f 85
perc
ent b
y w
eigh
t or v
olum
e, o
f spe
cific
cat
egor
ies o
f site
-app
lied
adhe
sives
and
seal
ants
use
d on
the
inte
rior
side
of th
e bu
ildin
g en
velo
pe sh
all c
ompl
y w
ith th
e VO
C co
nten
t lim
its in
IGCC
Tab
le 8
06.2
(1) o
r alte
rnat
ive
VOC
emiss
ion
limits
in IG
CC T
able
806
.2(2
). Th
e VO
C co
nten
t sha
ll be
det
erm
ined
in a
ccor
danc
e w
ith th
e ap
prop
riate
stan
dard
bei
ng e
ither
U.S
. EPA
Met
hod
24 o
r SCA
QM
D M
etho
d 30
4, 3
16A
or 3
16B.
The
exe
mpt
com
poun
d co
nten
t sha
ll be
det
erm
ined
by
eith
er S
CAQ
MD
Met
hods
302
and
303
or A
STM
D 3
960.
Tab
le 8
06.2
(1) a
dhes
ives
and
seal
ants
regu
lato
ry c
ateg
ory
and
VOC
cont
ent c
ompl
ianc
ede
term
inat
ion
shal
l con
form
to th
e SC
AQM
D Ru
le 1
168
Adhe
sive
and
Seal
ant A
pplic
atio
ns a
s am
ende
d on
1/7
/05.
The
prov
ision
s of t
his s
ectio
n sh
all n
ot a
pply
to a
dhes
ives
and
seal
ants
subj
ect t
o st
ate
or fe
dera
l con
sum
er p
rodu
ct V
OC
regu
latio
ns. H
VAC
duct
seal
ants
shal
l be
clas
sifie
d as
"Oth
er”
cate
gory
with
in th
e SC
AQM
D Ru
le 1
168
seal
ants
tabl
e.Ex
cept
ion:
HVA
C ai
r duc
t sea
lant
s are
not
requ
ired
to m
eet t
he e
miss
ions
or t
he V
OC
cont
ent r
equi
rem
ents
whe
n th
e ai
rte
mpe
ratu
re in
whi
ch th
ey a
re a
pplie
d is
less
than
40°
F (4
.5°C
).Ar
chite
ctur
al p
aint
s and
coa
tings
: A m
inim
um o
f 85
perc
ent b
y w
eigh
t or v
olum
e, o
f site
-app
lied
inte
rior a
rchi
tect
ural
coa
tings
shal
l com
ply
with
VO
C co
nten
t lim
its in
Tab
le 8
06.3
(1) o
r the
alte
rnat
e em
issio
ns li
mits
in IG
CC T
able
806
.3(2
). Th
e ex
empt
com
poun
d co
nten
t sha
ll be
det
erm
ined
by
ASTM
D 3
960.
Floo
ring:
A m
inim
um o
f 85
perc
ent o
f the
tota
l are
a of
floo
ring
inst
alle
d w
ithin
the
inte
rior o
f the
bui
ldin
g sh
all c
ompl
y w
ith th
ere
quire
men
ts o
f IGC
C Ta
ble
806.
4(2)
. Whe
re fl
oorin
g w
ith m
ore
than
one
dist
inct
pro
duct
laye
r is i
nsta
lled,
the
emiss
ions
from
each
laye
r sha
ll co
mpl
y w
ith th
ese
requ
irem
ents
. The
test
met
hodo
logy
use
d to
det
erm
ine
com
plia
nce
shal
l be
from
CDPH
/EHL
B/St
anda
rd M
etho
d V.
1.1,
Sta
ndar
d M
etho
d fo
r Tes
ting
VOC
Emiss
ions
Fro
m In
door
Sou
rces
, dat
ed F
ebru
ary
2010
.Th
e em
issio
ns te
stin
g sh
all b
e pe
rfor
med
by
a la
bora
tory
that
has
the
CDPH
/EHL
B/St
anda
rd M
etho
d V.
1.1
test
met
hodo
logy
inth
e sc
ope
of it
s ISO
170
25 A
ccre
dita
tion.
Whe
re p
ost-
man
ufac
ture
coa
tings
or s
urfa
ce a
pplic
atio
ns h
ave
not b
een
appl
ied,
the
floor
ing
liste
d in
IGCC
Tab
le 8
06.4
(1) s
hall
be d
eem
ed to
com
ply
with
the
requ
irem
ents
of I
GCC
Tabl
e 80
6.4(
2).
Acou
stic
al c
eilin
g til
es a
nd w
all s
yste
ms:
A m
inim
um o
f 85
perc
ent o
f aco
ustic
al c
eilin
g til
es a
nd w
all s
yste
ms,
by
squa
re fe
et,
shal
l com
ply
with
the
requ
irem
ents
of I
GCC
Tabl
e 80
6.5(
2). W
here
cei
ling
and
wal
l sys
tem
s with
mor
e th
an o
ne d
istin
ct p
rodu
ctla
yer a
re in
stal
led,
the
emiss
ions
from
eac
h la
yer s
hall
com
ply
with
thes
e re
quire
men
ts. T
he te
st m
etho
dolo
gy u
sed
tode
term
ine
com
plia
nce
shal
l be
from
CDP
H/EH
LB/S
tand
ard
Met
hod
V.1.
1, S
tand
ard
Met
hod
for T
estin
g VO
C Em
issio
ns F
rom
Indo
or S
ourc
es, d
ated
Feb
ruar
y 20
10. T
he e
miss
ions
test
ing
shal
l be
perf
orm
ed b
y a
labo
rato
ry th
at h
as th
eCD
PH/E
HLB/
Stan
dard
Met
hod
V.1.
1 te
st m
etho
dolo
gy in
the
scop
e of
its I
SO 1
7025
Acc
redi
tatio
n.W
here
pos
t-m
anuf
actu
re c
oatin
gs o
r sur
face
app
licat
ions
hav
e no
t bee
n ap
plie
d, th
e ce
iling
or w
all s
yste
ms l
isted
in IG
CC T
able
806.
5(1)
shal
l be
deem
ed to
com
ply
with
the
requ
irem
ents
of I
GCC
Tabl
e 80
6.5(
2).
Insu
latio
n: A
min
imum
of 8
5 pe
rcen
t of i
nsul
atio
n sh
all c
ompl
y w
ith th
e re
quire
men
ts o
f IGC
C Ta
ble
806.
6(1)
or I
GCC
Tabl
e80
8.6(
2). T
he te
st m
etho
dolo
gy u
sed
to d
eter
min
e co
mpl
ianc
e sh
all b
e fr
om C
DPH/
EHLB
/Sta
ndar
d M
etho
d V.
1.1,
Sta
ndar
dM
etho
d fo
r Tes
ting
VOC
Emiss
ions
Fro
m In
door
Sou
rces
, dat
ed F
ebru
ary
2010
. The
em
issio
ns te
stin
g sh
all b
e pe
rfor
med
by
ala
bora
tory
that
has
the
CDPH
/EHL
B/St
anda
rd M
etho
d V.
1.1
test
met
hodo
logy
in th
e sc
ope
of it
s ISO
170
25 A
ccre
dita
tion.
Sepa
ratin
g as
sem
blie
s: W
all a
nd fl
oor-
ceili
ng a
ssem
blie
s tha
t sep
arat
e a
mec
hani
cal o
r em
erge
ncy
gene
rato
r equ
ipm
ent r
oom
or sp
ace
from
the
rem
aind
er o
f the
bui
ldin
g sh
all h
ave
a so
und
tran
smiss
ion
clas
s (ST
C) o
f not
less
than
60
dete
rmin
ed in
acco
rdan
ce w
ith A
STM
E 9
0 an
d AS
TM E
413
, or f
or c
oncr
ete
mas
onry
and
cla
y m
ason
ry a
ssem
blie
s as c
alcu
late
d in
acc
orda
nce
with
TM
S 03
02 o
r as d
eter
min
ed in
acc
orda
nce
with
AST
M E
90
and
ASTM
E 4
13.
HVAC
bac
kgro
und
soun
d: H
VAC
syst
em c
ause
d ba
ckgr
ound
soun
d le
vels
for a
ll m
odes
of o
pera
tion
with
in ro
oms s
hall
be in
acco
rdan
ce w
ith th
e lo
wer
and
upp
er n
oise
crit
eria
(NC)
lim
its a
s sho
wn
in IG
CC T
able
807
.3.2
. Spe
cial
insp
ectio
ns sh
all b
ere
quire
d an
d co
nduc
ted
in a
ccor
danc
e w
ith IG
CC S
ectio
n 90
3.1
in o
rder
to d
emon
stra
te c
ompl
ianc
e.Sp
ecia
l ins
pect
ions
for s
ound
tran
smis
sion
: An
appr
oved
age
ncy,
em
ploy
ed b
y th
e bu
ildin
g ow
ner,
shal
l fur
nish
repo
rt(s
) of
test
find
ings
indi
catin
g th
at th
e re
sults
are
in c
ompl
ianc
e w
ith th
is se
ctio
n an
d th
e co
nstr
uctio
n do
cum
ents
. Disc
repa
ncie
s sha
llbe
bro
ught
to th
e at
tent
ion
of th
e de
sign
prof
essio
nal a
nd c
ode
offic
ial p
rior t
o th
e co
mpl
etio
n of
that
wor
k. A
fina
l tes
ting
repo
rt d
ocum
entin
g re
quire
d te
stin
g an
d co
rrec
tions
of a
ny d
iscre
panc
ies n
oted
in p
rior t
ests
shal
l be
subm
itted
at a
poi
nt in
time
agre
ed u
pon
by th
e bu
ildin
g ow
ner,
or b
uild
ing
owne
r's a
gent
, des
ign
prof
essio
nal,
and
the
code
offi
cial f
or p
urpo
ses o
fde
mon
stra
ting
com
plia
nce.
Exce
ptio
n: T
est r
epor
ts a
re n
ot re
quire
d fo
r app
rove
d as
sem
blie
s with
an
esta
blish
ed so
und
tran
smiss
ion
clas
s (ST
C) ra
ting.
Test
ing
for m
echa
nica
l and
em
erge
ncy
gene
rato
r equ
ipm
ent o
utsi
de o
f bui
ldin
gs: I
n ac
cord
ance
with
IGCC
Sec
tion
807.
3.1,
all
mec
hani
cal a
nd e
mer
genc
y ge
nera
tor e
quip
men
t sha
ll be
fiel
d te
sted
in a
ccor
danc
e w
ith T
able
903
.1. T
estin
g sh
all b
eco
nduc
ted
follo
win
g th
e co
mpl
ete
inst
alla
tion
of th
e eq
uipm
ent o
r gen
erat
ors,
the
inst
alla
tion
of so
und
redu
ctio
n ba
rrie
rs, a
ndba
lanc
ing
and
oper
atio
n of
the
equi
pmen
t or g
ener
ator
s. T
estin
g sh
all b
e at
loca
tions
repr
esen
ting
the
four
car
dina
l dire
ctio
nsfr
om th
e fa
ce o
f the
pro
ject
bui
ldin
g. S
uch
test
ing
shal
l occ
ur o
n a
Tues
day,
Wed
nesd
ay o
r Thu
rsda
y at
bot
h th
e da
y an
d ni
ght
times
with
in th
e pe
riods
show
n in
IGCC
Tab
le 8
07.3
.1.
Test
ing
for b
uild
ing
syst
em b
ackg
roun
d no
ise:
Tes
ting
shal
l be
exec
uted
in a
ccor
danc
e w
ith IG
CC S
ectio
n 80
7.3.
1 w
ithin
not
less
than
50
perc
ent o
f the
tota
l num
ber o
f roo
ms c
onta
ined
in a
bui
ldin
g or
stru
ctur
e, e
xclu
sive
of c
lose
ts a
nd st
orag
e ro
oms
less
than
50
squa
re fe
et in
are
a, a
nd e
xclu
sive
of to
ilet f
acili
ties i
n ac
cord
ance
with
Tab
le 9
03.1
. Tes
ting
shal
l occ
ur fo
llow
ing
the
com
plet
e in
stal
latio
n of
the
equi
pmen
t and
syst
ems,
the
inst
alla
tion
of a
ny so
und
redu
ctio
n ba
rrie
rs, a
nd b
alan
cing
and
oper
atio
n of
the
equi
pmen
t and
syst
ems.
COM
MIS
SIO
NIN
GTh
e Co
mm
issio
ning
Age
nt re
tain
ed b
y th
e O
wne
r sha
ll pe
rfor
m c
omm
issio
ning
dur
ing
cons
truc
tion
and
afte
r occ
upan
cy a
sre
quire
d by
IGCC
Tab
le 9
03.1
. Whe
re IG
CC T
able
903
.1 sp
ecifi
es th
at c
omm
issio
ning
is to
be
done
on
a pe
riodi
c ba
sis, t
heCo
mm
issio
ning
Age
nt sh
all p
rovi
de a
sche
dule
of p
erio
dic
com
miss
ioni
ng w
ith th
e su
bmitt
al d
ocum
ents
that
shal
l be
revi
ewed
and
appr
oved
by
the
code
offi
cial.
The
Com
miss
ioni
ng A
gent
shal
l be
qual
ified
and
shal
l dem
onst
rate
com
pete
nce,
to th
e sa
tisfa
ctio
n of
the
code
offi
cial,
for t
heco
mm
issio
ning
of t
he p
artic
ular
type
of c
onst
ruct
ion
or o
pera
tion.
The
Com
miss
ioni
ng A
gent
shal
l pro
vide
writ
ten
docu
men
tatio
n to
the
code
offi
cial d
emon
stra
ting
com
pete
nce
and
rele
vant
exp
erie
nce
or tr
aini
ng. E
xper
ienc
e or
trai
ning
shal
lbe
con
sider
ed re
leva
nt w
here
the
docu
men
ted
expe
rienc
e or
trai
ning
is re
late
d in
com
plex
ity to
the
sam
e ty
pe o
fco
mm
issio
ning
act
iviti
es fo
r pro
ject
s of s
imila
r com
plex
ity a
nd m
ater
ial q
ualit
ies.
Preo
ccup
ancy
repo
rt re
quire
men
t: Th
e GC
and
Com
miss
ioni
ng A
gent
shal
l kee
p re
cord
s of t
he c
omm
issio
ning
requ
ired
by IG
CCTa
ble
903.
1. T
he C
omm
issio
ning
Age
nt sh
all f
urni
sh c
omm
issio
ning
repo
rts t
o th
e ow
ner a
nd th
e re
gist
ered
des
ign
prof
essio
nal
in re
spon
sible
cha
rge
and,
upo
n re
ques
t, to
the
code
offi
cial.
Repo
rts s
hall
indi
cate
that
wor
k w
as o
r was
not
com
plet
ed in
conf
orm
ance
to a
ppro
ved
cons
truc
tion
docu
men
ts. D
iscre
panc
ies s
hall
be b
roug
ht to
the
imm
edia
te a
tten
tion
of th
e co
ntra
ctor
for c
orre
ctio
n. W
here
disc
repa
ncie
s are
not
cor
rect
ed, t
hey
shal
l be
brou
ght t
o th
e at
tent
ion
of th
e ow
ner,
code
offi
cial a
nd to
the
regi
ster
ed d
esig
n pr
ofes
siona
l in
resp
onsib
le c
harg
e pr
ior t
o th
e co
mpl
etio
n of
that
pha
se o
f the
wor
k. P
rior t
o th
e iss
uanc
eof
a C
ertif
icat
e of
Occ
upan
cy, a
fina
l com
miss
ioni
ng re
port
shal
l be
subm
itted
to a
nd a
ccep
ted
by th
e co
de o
fficia
l.
Post
-occ
upan
cy re
port
requ
irem
ent:
Post
-occ
upan
cy c
omm
issio
ning
shal
l occ
ur a
s spe
cifie
d in
the
appl
icab
le se
ctio
ns o
f thi
sco
de. A
pos
t-oc
cupa
ncy
com
miss
ioni
ng re
port
shal
l be
prov
ided
to th
e ow
ner w
ithin
30
mon
ths a
fter
the
Cert
ifica
te o
fO
ccup
ancy
is is
sued
for t
he p
roje
ct a
nd sh
all b
e m
ade
avai
labl
e to
the
code
offi
cial u
pon
requ
est.
BUIL
DIN
G O
PERA
TIO
NS
AND
MAI
NTE
NAN
CEGe
nera
l: Bu
ildin
g op
erat
ions
and
mai
nten
ance
doc
umen
ts in
acc
orda
nce
with
IGCC
Sec
tion
904.
3 sh
all b
e su
bmitt
ed, b
y th
e GC
,to
the
owne
r prio
r to
the
issua
nce
of th
e Ce
rtifi
cate
of O
ccup
ancy
. Rec
ord
docu
men
ts sh
all b
e in
acc
orda
nce
with
IGCC
Sec
tion
904.
2. T
he b
uild
ing
owne
r sha
ll fil
e a
lett
er w
ith th
e co
de o
fficia
l cer
tifyi
ng th
e re
ceip
t of r
ecor
d do
cum
ents
and
bui
ldin
gop
erat
ions
and
mai
nten
ance
doc
umen
ts. A
t lea
st o
ne c
opy
of th
ese
mat
eria
ls sh
all b
e in
the
poss
essio
n of
the
owne
r and
at
leas
t one
add
ition
al c
opy
shal
l rem
ain
with
the
build
ing
thro
ugho
ut th
e lif
e of
the
stru
ctur
e.
Reco
rd d
ocum
ents
: The
cov
er sh
eet o
f the
reco
rd d
ocum
ents
for t
he p
roje
ct sh
all c
lear
ly in
dica
te th
at a
t lea
st o
ne c
opy
of th
em
ater
ials
shal
l be
in th
e po
sses
sion
of th
e ow
ner.
Reco
rd d
ocum
ents
shal
l inc
lude
all
of th
e fo
llow
ing:
1. C
opie
s of t
he a
ppro
ved
cons
truc
tion
docu
men
ts, i
nclu
ding
pla
ns a
nd sp
ecifi
catio
ns.
2. A
s-bu
ilt p
lans
and
spec
ifica
tions
indi
catin
g th
e ac
tual
loca
tions
of p
ipin
g, d
uctw
ork,
val
ves,
con
trol
s, e
quip
men
t, ac
cess
pane
ls, li
ghtin
g an
d ot
her s
imila
r com
pone
nts w
here
they
are
con
ceal
ed o
r are
inst
alle
d in
loca
tions
oth
er th
an th
ose
indi
cate
don
the
appr
oved
con
stru
ctio
n do
cum
ents
.3.
For
site
s tha
t hav
e pr
evio
usly
bee
n a
brow
nfie
ld, o
r req
uire
d en
viro
nmen
tal c
orre
ctiv
e ac
tion,
rem
edia
tion
or re
stor
atio
n at
the
fede
ral,
stat
e or
loca
l lev
el, c
opie
s of e
ngin
eerin
g an
d in
stitu
tiona
l con
trol
info
rmat
ion
shal
l be
prov
ided
.4.
A c
opy
of th
e Ce
rtifi
cate
of O
ccup
ancy
.
Build
ing
oper
atio
ns a
nd m
aint
enan
ce d
ocum
ents
: The
bui
ldin
g op
erat
ions
and
mai
nten
ance
doc
umen
ts sh
all c
onsis
t of
man
ufac
ture
r's sp
ecifi
catio
ns a
nd re
com
men
datio
ns, p
rogr
amm
ing
proc
edur
es a
nd d
ata
poin
ts, n
arra
tives
, and
oth
er m
eans
of
illus
trat
ing
to th
e ow
ner h
ow th
e bu
ildin
g, si
te a
nd sy
stem
s are
inte
nded
to b
e m
aint
aine
d an
d op
erat
ed. T
he fo
llow
ing
info
rmat
ion
shal
l be
incl
uded
in th
e m
ater
ials,
as a
pplic
able
to th
e sp
ecifi
c pr
ojec
t:1.
Dire
ctio
ns to
the
owne
r or o
ccup
ant o
n th
e m
anua
l cov
er sh
eet i
ndic
atin
g th
at a
t lea
st o
ne c
opy
of th
e m
ater
ials
shal
l be
inth
e po
sses
sion
of th
e ow
ner o
r occ
upan
t.2.
Ope
ratio
ns a
nd m
aint
enan
ce m
anua
ls fo
r equ
ipm
ent,
prod
ucts
and
syst
ems i
nsta
lled
unde
r or r
elat
ed to
the
prov
ision
s of
IGCC
Cha
pter
4 in
clud
ing,
but
not
lim
ited
to, t
he fo
llow
ing,
as a
pplic
able
:2.
1. V
eget
ativ
e sh
adin
g, v
eget
ativ
e ro
ofs a
nd n
atur
al re
sour
ce p
rote
ctio
ns a
nd se
tbac
ks.
2.2.
Wat
er-c
onse
rvin
g la
ndsc
ape
and
irrig
atio
n sy
stem
s.
2.3.
Sto
rmw
ater
man
agem
ent s
yste
ms.
2.4.
Per
man
ent e
rosio
n co
ntro
l mea
sure
s.2.
5. L
ands
cape
or t
ree
man
agem
ent p
lans
.3.
Ope
ratio
ns a
nd m
aint
enan
ce d
ocum
ents
for m
ater
ials,
pro
duct
s, a
ssem
blie
s and
syst
ems i
nsta
lled
unde
r or r
elat
ed to
the
prov
ision
s of t
his c
ode
for m
ater
ial r
esou
rce
cons
erva
tion
in a
ccor
danc
e w
ith IG
CC C
hapt
er 5
incl
udin
g, b
ut n
ot li
mite
d to
, the
follo
win
g, a
s app
licab
le:
3.1.
Car
e an
d m
aint
enan
ce in
stru
ctio
ns a
nd re
com
men
ded
repl
acem
ent s
ched
ule
for f
loor
ing,
incl
udin
g, b
ut n
ot li
mite
d to
,ca
rpet
ing,
wal
k-of
f mat
s and
tile
.3.
2. C
are
and
mai
nten
ance
inst
ruct
ions
for n
atur
al m
ater
ials
incl
udin
g, b
ut n
ot li
mite
d to
, woo
d, b
io-b
ased
mat
eria
ls an
d st
one.
3.3.
Ava
ilabl
e m
anuf
actu
rer's
inst
ruct
ions
on
mai
nten
ance
for:
3.3.
1. E
xter
ior w
all f
inish
es.
3.3.
2. R
oof c
over
ings
.3.
3.3.
Ext
erio
r doo
rs, w
indo
ws a
nd sk
ylig
hts.
3.4.
Info
rmat
ion
and
reco
mm
ende
d sc
hedu
le fo
r req
uire
d ro
utin
e m
aint
enan
ce m
easu
res,
incl
udin
g, b
ut n
ot li
mite
d to
, pai
ntin
gan
d re
finish
ing.
4. O
pera
tions
and
mai
nten
ance
doc
umen
ts fo
r equ
ipm
ent,
prod
ucts
and
syst
ems i
nsta
lled
unde
r or r
elat
ed to
the
prov
ision
s of
this
code
for e
nerg
y co
nser
vatio
n in
acc
orda
nce
with
IGCC
Cha
pter
6 in
clud
ing,
but
not
lim
ited
to, t
he fo
llow
ing:
4.1.
Hea
ting,
ven
tilat
ing
and
air-
cond
ition
ing
syst
ems i
nclu
ding
:4.
1.1.
Rec
omm
ende
d eq
uipm
ent m
aint
enan
ce sc
hedu
le.
4.1.
2. A
ir fil
ters
and
flui
d fil
ters
, inc
ludi
ng re
com
men
ded
repl
acem
ent s
ched
ule
and
mat
eria
ls.4.
1.3.
Tim
e cl
ocks
, inc
ludi
ng se
ttin
gs d
eter
min
ed d
urin
g co
mm
issio
ning
.4.
1.4.
Pro
gram
mab
le c
ontr
ols a
nd th
erm
osta
ts, i
nclu
ding
sett
ings
det
erm
ined
dur
ing
com
miss
ioni
ng.
4.2.
Dom
estic
hot
wat
er sy
stem
s inc
ludi
ng p
erfo
rman
ce c
riter
ia a
nd c
ontr
ols.
4.3.
Bui
ldin
g th
erm
al e
nvel
ope
syst
ems i
nclu
ding
:4.
3.1.
Gla
zing
syst
ems i
nspe
ctio
n sc
hedu
le.
4.3.
2. P
erfo
rman
ce c
riter
ia fo
r rep
lace
men
ts a
nd re
pairs
.4.
3.3.
Info
rmat
ion
and
reco
mm
ende
d sc
hedu
le o
n re
quire
d ro
utin
e m
aint
enan
ce m
easu
res,
incl
udin
g bu
t not
lim
ited
to,
seal
ants
, mor
tar j
oint
s and
scre
ens.
4.4.
Ele
ctric
al a
nd li
ghtin
g sy
stem
s inc
ludi
ng:
4.4.
1. T
echn
ical
spec
ifica
tions
and
ope
ratin
g in
stru
ctio
ns fo
r ins
talle
d lig
htin
g eq
uipm
ent.
4.4.
2. L
umin
aire
mai
nten
ance
and
cle
anin
g pl
an.
4.4.
3. L
amp
sche
dule
, rec
omm
ende
d re
lam
ping
pla
n, a
nd la
mp
disp
osal
info
rmat
ion.
4.4.
4. P
rogr
amm
able
and
aut
omat
ic c
ontr
ols d
ocum
enta
tion,
incl
udin
g se
ttin
gs d
eter
min
ed d
urin
g co
mm
issio
ning
.4.
4.5.
Occ
upan
t sen
sor a
nd d
aylig
ht se
nsor
s doc
umen
tatio
n, in
clud
ing
sett
ings
det
erm
ined
dur
ing
com
miss
ioni
ng.
4.5.
Aut
omat
ic d
eman
d re
duct
ion
syst
ems.
5. O
pera
tions
and
mai
nten
ance
doc
umen
ts fo
r equ
ipm
ent,
prod
ucts
and
syst
ems i
nsta
lled
unde
r or r
elat
ed to
the
prov
ision
s of
this
code
for w
ater
con
serv
atio
n in
acc
orda
nce
with
IGCC
Cha
pter
7, i
nclu
ding
, but
not
lim
ited
to th
e fo
llow
ing:
5.1.
Dom
estic
fixt
ures
.5.
2. W
ater
-reg
ulat
ing
devi
ces i
nclu
ding
fauc
ets a
nd v
alve
s.5.
3. Ir
rigat
ion
and
rain
wat
er a
nd g
ray
wat
er c
atch
men
t.6.
Ope
ratio
ns a
nd m
aint
enan
ce d
ocum
ents
for e
quip
men
t pro
duct
s and
syst
ems u
nder
or r
elat
ed to
the
prov
ision
s of t
his c
ode
for i
ndoo
r env
ironm
enta
l qua
lity
in a
ccor
danc
e w
ith IG
CC C
hapt
er 8
, inc
ludi
ng, b
ut n
ot li
mite
d to
, the
follo
win
g:6.
1. H
umid
ifica
tion/
dehu
mid
ifica
tion.
6.2.
Gre
en c
lean
ing
prod
ucts
, pro
cedu
res a
nd te
chni
ques
.6.
3. R
ecom
men
ded
win
dow
cle
anin
g sc
hedu
le.
6.4.
Ven
tilat
ion
cont
rols.
6.5.
Flo
or fi
nish
es.
6.6.
Fire
plac
es a
nd c
ombu
stio
n ap
plia
nces
.
THES
E PL
ANS
ARE
INST
RUM
ENTS
OF
PROF
ESSI
ONAL
SER
VICE
AND
ARE
PROT
ECTE
D BY
COM
MON
LAW
, STA
TUTO
RY A
NDOT
HER
RES
ERVE
D RI
GHTS
INCL
UDIN
G CO
PYRI
GHT.
TH
EY M
AYNO
T BE
REP
RODU
CED
OR U
SED
FOR
ANY
PURP
OSE
WIT
HOU
TTH
E W
RITT
EN C
ONSE
NT O
F TH
E DE
SIGN
PRO
FESS
IONA
L©20
14
OFF
ICE
BU
ILD
ING
2 S
TOR
Y10
,604
SF.
51 P
AR
KS
MO
NU
ME
NT
SIG
N A
0.2
3 C
AR
GA
RA
GE
US
PS
BO
X
BIK
E R
AC
KS
CU
RB
RA
MP
(TO
TR
AS
HE
NC
LOS
UR
E)
CO
NC
RE
TE A
PR
ON
RE
: CIV
IL
BE
NC
H
A0.
1
A7.
0-7.
1
A1.
0-5.
0
TYP
A0.
2
CU
-2
CU
-7
CU
-4
CU
-1
CU
-3
CU
-6
CU
-5
CU
-9
CU
-8
HC
PA
RK
ING
SIG
NS
17'-4
"
12'-8" 2'-3"
8"2'
-6"
3'-6
"
7'-0
" CLE
AR
(2) 1
" DIA
. SLE
EV
ES
FOR
CA
NE
BO
LTS
PE
R D
OO
R
6" S
TEE
L P
IPE
BO
LLA
RD
,C
ON
CR
ETE
FIL
LED
6" S
TEE
L P
IPE
BO
LLA
RD
.C
ON
CR
ETE
FIL
LED
, TY
P.
TRA
SH
EN
CLO
SU
RE
RE
CY
CLI
NG
EN
CLO
SU
RE
3'-9
"3'
-9"
2'-6
"
7'-0
" CLE
AR
3 Y
D. D
UM
PS
TER
3 Y
D. D
UM
PS
TER
1'-0" 6'-0" 6"
6'-0
" H x
4'8
" W M
ETA
L D
EC
KG
ATE
S. P
RIM
E &
PA
INT
TOM
ATC
H S
TUC
CO
11 2"M
ETA
L S
LID
E L
ATC
HB
Y C
ON
TRA
CTO
RM
ETA
L S
PA
CE
R. C
AP
&W
ELD
CO
NTI
NU
OU
S T
OP
OS
TS.
15b 4
2'-8"4'-6"
4"
16
1715b
154
RE
INFO
RC
ED
CO
NC
RE
TE S
LAB
(SLO
PE
TO
GA
TES
)
#5 B
AR
S @
12"
EA
. WA
Y
PA
INT
ALL
EX
PO
SE
D F
AC
ES
TO M
ATC
H S
TUC
CO
CE
ME
NTI
TIO
US
STU
CC
OR
E: F
INIS
H S
CH
ED
ULE
NE
W A
SP
HA
LTP
AR
KIN
G L
OT
RE
: CIV
IL
CA
ULK
TR
AN
SIT
ION
SE
ALA
NT
AT
ALL
SE
AM
S -T
YP
.
7'-4"
16 1715b
154
CO
MP
AC
TED
SU
BG
RA
DE
OR
SE
LEC
T FI
LL
#5 B
AR
S @
16"
O.C
.
BO
ND
BE
AM
W/ (
2) #
5 B
AR
S
8" C
ON
C. B
LOC
K,
GR
OU
T S
OLI
D
(2) #
5 B
AR
S
2'-0"
1'-0"
2'-6
"
1'-6
''
3'-0" 6"3'-O''
CO
NC
RE
TE P
AV
ING
GR
OU
T S
OLI
D6'
' DIA
. SC
H. 4
O S
TEE
L P
IPE
,
FIN
ISH
SM
OO
THC
ON
VE
X C
ON
CR
ETE
CA
P
CO
NC
RE
TE F
OU
ND
ATI
ON
1/2"
EX
PA
NS
ION
JO
INT
XX
XX
XX
XX
X
SE
ALA
NT
1'' CAP
4x4x
1/4
STE
EL
TUB
E
(3 P
ER
GA
TE, W
ELD
ED
TO
TU
BE
WE
LDA
BLE
STE
EL
BU
TT H
ING
ES
8" C
MU
, RE
: STR
UC
IN 2
'-0"x
3'-0
" CO
NC
. FO
UN
DA
TIO
N
3x3x
1/4
STE
EL
TUB
E D
OO
R F
RA
ME
PR
IME
& P
AIN
T TO
MA
TCH
STU
CC
O
1 1/
2", 1
6 G
A M
ETA
L D
EC
K G
ATE
P
RIM
E &
PA
INT
TO M
ATC
H S
TUC
CO
TY
P.
5-#5
1-#5
EA
. EN
D
PL5
/8x1
0x0'
-10"
W/4
- 5/8
"ØA
307
HE
AD
ED
AN
CH
OR
BO
LTS
(EM
BE
D 1
0")
TUB
E C
OL.
RE
: PLA
N,
GR
OU
T S
OLI
D
3/4"
NO
N-S
HR
INK
NO
N-M
ETA
LIC
GR
OU
T
2-#5
CO
NT.
1'-0"
3'-8" (MIN.)
3'-0
" SQ
.
XX
XX
XX
XX
XX
EN
CA
SE
CO
LUM
N IN
CO
NC
RE
TE T
O G
RA
DE
THES
E PL
ANS
ARE
INST
RUM
ENTS
OF
PROF
ESSI
ONAL
SER
VICE
AND
ARE
PROT
ECTE
D BY
COM
MON
LAW
, STA
TUTO
RY A
NDOT
HER
RES
ERVE
D RI
GHTS
INCL
UDIN
G CO
PYRI
GHT.
TH
EY M
AYNO
T BE
REP
RODU
CED
OR U
SED
FOR
ANY
PURP
OSE
WIT
HOU
TTH
E W
RITT
EN C
ONSE
NT O
F TH
E DE
SIGN
PRO
FESS
IONA
L©20
14
SC
ALE
: 1/1
6" =
1'-0
"
8'16
'0
32'
SE
E C
IVIL
DR
AW
ING
S F
OR
AD
DIT
ION
AL
DE
TAIL
S
FOR
EX
TER
IOR
FIN
ISH
ES
NO
T LI
STE
DIN
DR
AW
ING
, RE
FER
TO
A2.
1
4'-10"
12'-1
34"
STU
CC
O B
ELO
W
1'-818"
1'-0
"
39 S
F D
OU
BLE
SID
ED
, IN
TER
NA
LLY
ILLU
MIN
ATE
D S
IGN
CA
BIN
ET
WIT
H E
MB
OS
SE
D A
LUC
OB
ON
D F
AC
E B
Y S
IGN
CO
NTR
AC
TOR
. FIE
LD V
ER
IFY
OP
EN
ING
DIM
EN
SIO
NS
.
1'-7"5'-4"1'-6"
8'-4"
10'-1
34"
RE
: STR
UC
16 17154
1
8'-6
1 4"
4'-6"
934"
934"
1'-0"2'-0"
3'-0"
8"
(OP
EN
TO
BE
YO
ND
)
1'-7"5'-4"1'-6"
8'-4"
1'-5
34"
RE
: STR
UC
16 17154
1
+ 0'
-6"
T.O
. CO
NC
. BA
SE
(4) 3
/4" D
IA. X
30"
GA
LV.
AN
CH
OR
BO
LTS
FU
RN
ISH
ED
BA
SE
CO
VE
R, P
RO
VID
ED
W/ P
OLE
+ 0'
-0"
FIN
ISH
GR
D.
SE
T B
OLT
S P
ER
TE
MP
LATE
- 6'-0
"B
.O. F
OU
ND
ATI
ON
EQ
UA
LLY
SP
AC
ED
ON
18"
DIA
.(4
) #7
BA
RS
VE
RT.
x 7
'-2" L
G.
SIT
E E
LEC
TRIC
AL
PLA
NE
LEC
TRIC
AL
CO
ND
UIT
, SE
E
(7) #
3 TI
ES
ON
15"
CE
NTE
RS
HA
ND
HO
LE W
/CO
VE
R
SE
E S
ITE
PLA
N F
OR
NU
MB
ER
OF
SIT
E
6" M
INIM
UM
BE
LOW
FIN
ISH
ED
GR
AD
EP
AIN
T TO
MA
TCH
STU
CC
O A
LL E
XP
OS
ED
ALL
FO
UN
DA
TIO
N F
OR
MS
TO
BE
RE
MO
VE
D
+ 20
'-0"
TOP
OF
FIX
TUR
E
4" S
QU
AR
E P
OLE
3/4"
BA
SE
PLA
TEW
/11"
BO
LT C
IRC
LE
CIR
CLE
(3) #
3 TI
ES
AT
TOP
14" A
BO
VE
FD
N.
STU
B 3
/4" C
ON
DU
IT
WIT
H P
OLE
LIG
HTS
.
CO
NC
RE
TE F
OU
ND
ATI
ON
BA
SE
PLA
TE
NO
TE:
2'-6" MIN.
6'-0"6"
2'-0
" DIA
.
4"
20'-0"
19'-6"
6"
11"
2'-0
" MIN
.TO
CU
RB
SIT
E L
IGH
T FI
XTU
RE
RE
FER
TO
SIT
E E
LEC
TRIC
AL
PLA
NFO
R M
OD
EL
No.
RE
FER
TO
SIT
E E
LEC
TRIC
AL
PLA
NFO
R M
OD
EL
No.
ALL
FO
UN
DA
TIO
N F
OR
MS
TO
BE
RE
MO
VE
D 6
" MIN
IMU
M B
ELO
W F
INIS
HE
D G
RA
DE
.
SIT
E L
IGH
TIN
G N
OTE
:
INC
LUD
ED
IN T
HE
CO
NTR
AC
T B
Y T
HE
ELE
CTR
ICA
L C
ON
TRA
CTO
R.
RE
GIS
TER
ED
PR
OFE
SS
ION
AL
EN
GIN
EE
R A
ND
DO
CU
ME
NTE
D IN
TH
E S
HO
P
INC
LUD
ING
SH
OP
DR
AW
ING
S, S
OIL
TE
STI
NG
AN
D D
ES
IGN
FE
ES
SH
ALL
BE
DR
AW
ING
S.
ALL
AS
SO
CIA
TED
CO
STS
FO
R T
HE
TO
TAL
INS
TALL
ATI
ON
VE
RIF
IED
BY
TH
EO
N A
CTU
AL
SIT
E S
OIL
BO
RIN
GS
AN
D A
NA
LYS
IS F
OR
EA
CH
PO
LE L
OC
ATI
ON
AS
SH
OP
DR
AW
ING
S M
AY
BE
FO
R W
OR
ST
CA
SE
SO
IL C
ON
DIT
ION
S O
R M
AY
BE
BA
SE
D
SH
OW
CO
MP
LIA
NC
E W
ITH
TH
E A
PP
LIC
AB
LE B
UIL
DIN
G C
OD
E, F
OR
WIN
D L
OA
DIN
G.
LUM
INA
IRE
, AN
D R
EIN
FOR
CE
D C
ON
CR
ETE
EN
CA
SE
ME
NT
CA
LCU
LATI
ON
S T
OP
RO
FES
SIO
NA
L E
NG
INE
ER
. S
HO
P D
RA
WIN
GS
SH
ALL
INC
LUD
E T
HE
PO
LE,
PR
OV
IDE
SH
OP
DR
AW
ING
S S
IGN
ED
AN
D S
EA
LED
BY
A R
EG
ISTE
RE
D
14
131
16 17154
(2) #
5 C
ON
T.
(3) 2
x12
BE
AM
2X6
FRA
MIN
G
EX
T G
RA
DE
PLY
WO
OD
2x8
RA
FTE
RS
2x B
LOC
KIN
G
8" C
MU
SO
LID
GR
OU
T W
/ #5
@ 2
4"O
.C. V
ER
T. C
EN
TER
IN C
ELL
S.
CU
LTU
RE
D S
TON
E T
O M
ATC
HB
UIL
DIN
G
6'-1034"
2'-0" 1'-0"
2'-8
"
3'-0"
8"
14131
16 17154
8" C
MU
SO
LID
GR
OU
T W
/ #5
@ 2
4"O
.C. V
ER
T. C
EN
TER
IN C
ELL
S.
(2) #
5 C
ON
T.
STU
CC
O. P
AIN
T TO
MA
TCH
PR
IMA
RY
BU
ILD
ING
STU
CC
O C
OLO
R
CU
LTU
RE
D S
TON
E T
O M
ATC
HB
UIL
DIN
G
BA
CK
LIT
ALU
MIN
UM
SIG
N C
AB
INE
TB
Y S
IGN
CO
NTR
AC
TOR
(3) 2
x12
BE
AM
2X6
FRA
MIN
G
EX
T G
RA
DE
PLY
WO
OD
2x8
RA
FTE
RS
2x B
LOC
KIN
G
STA
ND
ING
SE
AM
ME
TAL
RO
OF
BE
RR
IDG
E "C
EE
-LO
CK
" STA
ND
ING
SE
AM
ME
TAL
RO
OF,
RE
D
CE
ME
NTI
TIO
US
STU
CC
OS
TO O
R E
QU
AL
WIT
H T
AN
ELA
STO
ME
RIC
CO
ATI
NG
,
FAS
CIA
PR
EFI
NIS
HE
D M
ETA
L FA
SC
IA, R
ED
SO
FFIT
PR
EFI
NIS
HE
D T
AN
1/4
"x X
" ME
TAL
LAP
PA
NE
L
MA
NU
FAC
TUR
ED
STO
NE
VE
NE
ER
MA
NU
FAC
TUR
ED
STO
NE
CA
P
LE
DG
E S
TYLE
MA
NU
FAC
TUR
ED
STO
NE
MA
NU
FAC
TUR
ED
STO
NE
BA
SE
MA
NU
FAC
TUR
ED
STO
NE
VE
NE
ER
MA
NU
FAC
TUR
ED
STO
NE
VE
NE
ER
1 4 13 14 15 16 17
*U
SE
MFG
RE
CO
ME
ND
ED
JO
INT
SP
AC
ING
10'-1
34"
10'-0
"8'
-61 4"
4
THES
E PL
ANS
ARE
INST
RUM
ENTS
OF
PROF
ESSI
ONAL
SER
VICE
AND
ARE
PROT
ECTE
D BY
COM
MON
LAW
, STA
TUTO
RY A
NDOT
HER
RES
ERVE
D RI
GHTS
INCL
UDIN
G CO
PYRI
GHT.
TH
EY M
AYNO
T BE
REP
RODU
CED
OR U
SED
FOR
ANY
PURP
OSE
WIT
HOU
TTH
E W
RITT
EN C
ONSE
NT O
F TH
E DE
SIGN
PRO
FESS
IONA
L©20
14