DEPARTMENT OF INSTRUMENTATION AND CONTROL ENGINEERING . MEASURING THE HYSTERESIS LOOP OF THE TOROIDAL CORE USING LABVIEW TO OPTIMIZE THE DESIGN OF PMSM. AUTHOR: ING. ZDEN ĚK NOVÁK SUPERVISOR: DOC. ING. JAN CHYSKÝ, CSC. Presentation overview. Why to measure hysteresis loop - PowerPoint PPT Presentation
Citation preview
MEASURING THE HYSTERESIS LOOP OF THE TOROIDAL CORE USING LABVIEW
TO OPTIMIZE THE DESIGN OF PMSM
AUTHOR: ING. ZDENĚK NOVÁKSUPERVISOR: DOC. ING. JAN CHYSKÝ, CSC.
DEPARTMENT OF INSTRUMENTATION AND CONTROL ENGINEERING
Presentation overview
Why to measure hysteresis loopDesign of hysteresis measurementAnalyzing acquired dataApplication of analyzed dataVerification of FEMM analysisConclusion
PMSM
Goal: 250 000 rpmPower output: 5kW
PMSM
sinusoidal filter Control
board
Why to measure hysteresis loopFlux Density [T]
Flux Density [T]In Opposite Direction
Magnetic flux intensity [A/m]
Magnetic flux intensity [A/m]In OppositeDirection
Permanent magnet synchronous motor (PMSM)
Hysteresis loop
WHY TO DO IT
Design of hysteresis measurement
Measuring procedurer
tiNtH
2)(
)( 11 t
duSN
BtB0
22
0 )(1)(
t
duRC
tv0
22 )(1)(
HOW TO DO IT
Toroidal core with winding
First winding Second winding
Workplace
Amplifier and cooling
Signal generator
Power source
integratorDAQ card
PCCoil
Design of hysteresis measurement
Program block diagram
HOW TO DO IT
DAQ Assistant
Writing to Measurement
File
XY Graph
Variables
Design of hysteresis measurement
GUI from LabVIEW
HOW TO DO IT
Analyzing acquired data
Hysteresis loop of the toroidal shape core;
applied current 3 A, applied frequency 250 Hz
HOW TO DO IT
Application of analyzed data
FOR WHAT USE IT
Implementation into FEMM
software
Application of analyzed data
Results of the FEMM analysis
FOR WHAT USE IT
Verification of FEMM analysis
PMSM prototype
FOR WHAT USE IT
Torque of PMSM in FEMM = 0.01... [N.m]
Activating PMSM
Torque of real PMSM= 0.01... [N.m]
For current 4A:
Video na internetu
ConclusionData for B-H curve of the proposed material
were acquired and analyzedB-H characteristic was implemented into
FEMM software and some parameters were verified
Next stepsOptimization of PMSM based on FEMM model Verification of FEMM modelConsidering the possibility of using other
materials and design
SUMMARY
Thank you !Děkuji !Dziękuję !감사합니다 !