Measurement in Oil & Gas Industry

Embed Size (px)

DESCRIPTION

O&G

Citation preview

  • 9062

    1127

    4 Ed

    . 1 02/20

    12 - Non

    con

    tractua

    l doc

    umen

    t. Co

    nfirm

    spe

    cificatio

    ns before orde

    ring.

    Measurement in the Oil Industry

    Guaranteeing maximum safety at every stage in the oil sector

    nOperationsinoilfields:drillingandgeneratorsets

    n Inrefineries:thermographyandmaintenance

    nDuringtransport:cathodicprotectionandequipotentiality

    A complete range of instruments offering solutions for all your applications

  • C.A 8335AC/DC Power Analyser Testingofgeneratorsets Recordingofalltheparametersoveronemonth

    Inrush

    C.A 6549 Insulationmeasurementupto5kV Calculationofqualityratios Temperaturecompensation Stepvoltagemode

    EQUIPOTENTIALITY OF THE CHASSIS-EARTHS AND EARTHS

    All the metal chassis-earths are bonded together and then bonded to the earth to help protect the installation against arcing. Indeed, the presence of several independent earthing networks close to one another may lead to a significant difference in potential which could prove hazardous for both people and property. If this is the case, the different earth networks must be interconnected, either via the underground earth or by special buried bonds, to ensure equipotentiality.

    MX 57EXATEX "Gas and Dust" Multimeter Explosiveatmospheres ResettableATEXinstrument

    C.A 6415 Earthloopmeasurement Highcurrentorleakage-currentmeasurements

    Alarmsfunction

    C.A 1888 Thermographic Camera MIXVISION Checkingoffirehazards Predictiveandpreventivemaintenance Infraredmeasurementoftanklevelsandverificationofvalvepositions

    C.A 1727Contact and no-contact Tachometer Maintenance

    MX 59HDDigital Multimeter IP67 Ruggedandleakproof

    PIPELINES

    Made of steel and covered with an anti-corrosive coating, pipelines are designed for transporting oil. To ensure maximum safety, the buried parts of pipelines are also equipped with cathodic protection to prevent chemical or electrochemical corrosion.

    C.A 6472 Measurementofearthing,derrickearthingandlightningarrestorsupto5kHz

    Measurementofcathodicprotection

    Equipotentialitytestingofearthbondsandlightningarrestors

    C.A 6250 Micro-Ohmmeter Testingofsurfaceconditionandmetallization

    OX 7204200 MHz Oscilloscope RemoteEthernetcommunicationandstorageonSDcard

    Probixsafetyaccessories:current,voltage,temperature,weak4-20mA/0-10Vsignals

    F607 TRMS Multimeter Clamp Singleandtotalthree-phasepowervalues

    Workondrillingenginesoperatingat3,000Adc

    CATHODIC PROTECTION

    To reduce the potential of the pipes to the required value, the network is connected at one or more points to the negative pole of a DC current source. This negative voltage is achieved by connecting a DC power supply between the pipeline and the ground, thus creating a current outside the "earthing" flowing through the ground and then in the pipeline. In this situation, the pipeline serves as the cathode for the circuit.

    C.A 1866 Infrared Thermometer No-contacttemperaturemeasurement

    Alimentation DC

    Mise la terre

    Pipeline

  • Your distributor90

    6211

    274 Ed

    . 1 02/20

    12 - Non

    con

    tractua

    l doc

    umen

    t. Co

    nfirm

    spe

    cificatio

    ns before orde

    ring.

    FRANCEChauvin Arnoux190, rue Championnet75876 PARIS Cedex 18Tel: +33 1 44 85 44 38Fax: +33 1 46 27 95 [email protected]

    uNitEd kiNgdomChauvin Arnoux LtdUnit 1 Nelson Ct, Flagship Sq, Shaw Cross Business PkDewsbury, West Yorkshire - WF12 7THTel: +44 1924 460 494Fax: +44 1924 455 [email protected]

    middLE EAstChauvin Arnoux middle EastP.O. BOX 60-1541241 2020 JAL EL DIB - LEBANONTel: +961 1 890 425Fax: +961 1 890 [email protected]

    C.A 1727Contact and no-contact Tachometer

    Rotationandlinearspeed Rangefrom6to100,000RPM Eventcountingfrom0to99,999

    C.A 6415Earth and loop-testing Clamp

    Resistance:0.10to1,200(7cal.) Leakagecurrentfrom1mAto30.00A Batterylifeof1,000measurementseachlasting30s

    C.A 64725-in 1 Earth and resistivity Tester

    Earthandpylon-earthmeasurements, resistivity,earthcoupling,soilpotential,resistanceandcontinuity

    Analysisofthefrequencybehaviourofearthbonds(41Hzto5kHz) C.A 8335

    AC/DC Power Analyser

    4voltageinputs,4currentinputs Inrush Checkingofgeneratorsets Recordingofalltheparameterssimultaneouslyoveraone-monthperiod

    Voltageratio

    C.A 65495 kV Insulation Tester

    Stepvoltage:5steps AutomaticcalculationoftheDAR,PIandDDqualityratios

    Measurementofvoltage,capacitanceandleakagecurrent

    F607TRMS AC, DC and AC+DC Multimeter Clamp

    Upto2,000Aacor3,000Adc/ac+dc Clampingdiam.60mmW,varandVApowermeasurements Harmonicandfrequencyanalysis DatarecordingandBluetoothcommunication

    C.A 625010 A Micro-Ohmmeter

    Chassis-earthcontinuitytesting Verificationofmechanicalbonds Rangefrom1to2500

    K2AC and DC Current Clamp

    Measurementof4-20mAsignalsMeasurementrangefrom0.1mAto450mAdc

    CompatiblewithallMetrixmultimetersandfrom0.1mAto300mArms

    C.A 1866Infrared Thermometer

    Largemeasurementrangefrom-50Cto+1,000C Speciallydesignedformaintenance

    MX 59HDIP67 Digital Multimeter AC/DCvoltagefrom500mVto600V AC/DCcurrentranges:500A,5mA,50mA,500mA&10A

    C.A 1888 MIXVISION Thermographic Camera

    Temperaturesfrom-20Cto+600C,and+1,500C(option)

    Measurementoflevelsincontainers Storageof1,000radiometricimagesonMiniSDcard

    OX 7204 Portable Oscilloscope for maintenance

    200MHz 4isolatedchannels,600VCATIIIMeasurementandrecording Probixsafetyaccessories:current,voltage,weaksignals,temperature

    EthernetandUSB

    MX 57Ex50,000-count TRMS ATEX Multimeter

    100%ATEXGasandDust 600VCATIII ResettableATEXinstrument,inexplosiveandnon-explosiveenvironments