25
Dr Marc Heuschkel Ch. Champ Petau 2 CH-1053 Bretigny Switzerland [email protected] http://www.qwane.com MEA60 Biochips Product Catalogue

MEA60 Biochips Product Catalogue - Qwane · Dr Marc Heuschkel Ch. Champ Petau 2 CH-1053 Bretigny Switzerland [email protected] MEA60 Biochips Product Catalogue

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Dr Marc Heuschkel Ch. Champ Petau 2 CH-1053 Bretigny Switzerland [email protected] http://www.qwane.com

MEA60 Biochips

Product Catalogue

MEA60-100-10-PtBlack

Substrate dimension: 12mm x 12mm x 0.7mmSubstrate material: GlassElectrode material: Platinum blackInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø10µmInterelectrode distance: 100µm (centre to centre)Impedance (@1kHz): 150-200kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-100-30-3D

Substrate dimension: 12mm x 12mm x 0.6mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: 3D tip-shapedElectrode height: 25-40µm

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø30µmInterelectrode distance: 100µm (centre to centre)Impedance (@1kHz): 500-800kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-100-30-Pt

Substrate dimension: 12mm x 12mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø30µmInterelectrode distance: 100µm (centre to centre)Impedance (@1kHz): 800-1100kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-100-30-PtBlack

Substrate dimension: 12mm x 12mm x 0.7mmSubstrate material: GlassElectrode material: Platinum blackInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø30µmInterelectrode distance: 100µm (centre to centre)Impedance (@1kHz): 20-30kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-200-10-PtBlack

Substrate dimension: 12mm x 12mm x 0.7mmSubstrate material: GlassElectrode material: Platinum blackInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø10µmInterelectrode distance: 200µm (centre to centre)Impedance (@1kHz): 150-200kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-200-30-3D

Substrate dimension: 12mm x 12mm x 0.5mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: 3D tip-shapedElectrode height: 50-70µm

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø30µmInterelectrode distance: 200µm (centre to centre)Impedance (@1kHz): 450-650kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-200-30-Pt

Substrate dimension: 12mm x 12mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø30µmInterelectrode distance: 200µm (centre to centre)Impedance (@1kHz): 800-1100kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-200-30-PtBlack

Substrate dimension: 12mm x 12mm x 0.7mmSubstrate material: GlassElectrode material: Platinum blackInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø30µmInterelectrode distance: 200µm (centre to centre)Impedance (@1kHz): 20-30kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-200-50-ITO

Substrate dimension: 12mm x 12mm x 0.7mmSubstrate material: GlassElectrode material: Indium-tin oxide (ITO)Insulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 59Reference electrode: One internal reference (N°15)

Electrode layout: 8x8 matrixElectrodes dimension: Ø50µmInterelectrode distance: 200µm (centre to centre)Impedance (@1kHz): 900-1200kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-4-Well-Pt

Substrate dimension: 21mm x 21mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 56 (14 in each well)Reference electrode: One internal reference per well;

electrodes N°15, 42, 57, 84

Electrode layout: 4x4 matrix in each wellElectrodes dimension: Ø30µmInterelectrode distance: 200µm (centre to centre)Impedance (@1kHz): 800-1100kΩ

Culture chamber: Plexiglass chamberswell Ø6mm, height 8mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-4-Well-PtBlack

Substrate dimension: 21mm x 21mm x 0.7mmSubstrate material: GlassElectrode material: Platinum blackInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 56 (14 in each well)Reference electrode: One internal reference per well;

electrodes N°15, 42, 57, 84

Electrode layout: 4x4 matrix in each wellElectrodes dimension: Ø30µmInterelectrode distance: 200µm (centre to centre)Impedance (@1kHz): 20-30kΩ

Culture chamber: Plexiglass chamberswell Ø6mm, height 8mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-400-70

Substrate dimension: 15mm x 15mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 60Reference electrode: external reference to be used

Electrode layout: 8x8 matrixElectrodes dimension: Ø70µmInterelectrode distance: 400µm (centre to centre)Impedance (@1kHz): 250-300kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-400-70-3D

Substrate dimension: 15mm x 15mm x 0.5mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: 3D tip-shapedElectrode height: 70-80µm

Recording electrodes: 60Reference electrode: External reference to be used

Electrode layout: 8x8 matrixElectrodes dimension: Ø70µmInterelectrode distance: 400µm (centre to centre)Impedance (@1kHz): 200-300kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-500-75

Substrate dimension: 15mm x 15mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 60Reference electrode: external reference to be used

Electrode layout: 8x8 matrixElectrodes dimension: Ø75µmInterelectrode distance: 500µm (centre to centre)Impedance (@1kHz): 230-280kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-500-75-3D

Substrate dimension: 15mm x 15mm x 0.5mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: 3D tip-shapedElectrode height: 70-80µm

Recording electrodes: 60Reference electrode: External reference to be used

Electrode layout: 8x8 matrixElectrodes dimension: Ø75µmInterelectrode distance: 500µm (centre to centre)Impedance (@1kHz): 150-250kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-600-80

Substrate dimension: 15mm x 15mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 60Reference electrode: external reference to be used

Electrode layout: 8x8 matrixElectrodes dimension: Ø80µmInterelectrode distance: 600µm (centre to centre)Impedance (@1kHz): 200-250kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-600-80-3D

Substrate dimension: 15mm x 15mm x 0.5mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: 3D tip-shapedElectrode height: 70-80µm

Recording electrodes: 60Reference electrode: External reference to be used

Electrode layout: 8x8 matrixElectrodes dimension: Ø80µmInterelectrode distance: 600µm (centre to centre)Impedance (@1kHz): 100-200kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-6x10-400

Substrate dimension: 15mm x 15mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 60Reference electrode: external reference to be used

Electrode layout: 6x10 matrixElectrodes dimension: Ø70µmInterelectrode distance: 400µm (centre to centre)Impedance (@1kHz): 250-300kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-6x10-400-3D

Substrate dimension: 15mm x 15mm x 0.5mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: 3D tip-shapedElectrode height: 70-80µm

Recording electrodes: 60Reference electrode: External reference to be used

Electrode layout: 6x10 matrixElectrodes dimension: Ø70µmInterelectrode distance: 400µm (centre to centre)Impedance (@1kHz): 200-300kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-6x10-500

Substrate dimension: 15mm x 15mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 60Reference electrode: external reference to be used

Electrode layout: 6x10 matrixElectrodes dimension: Ø75µmInterelectrode distance: 500µm (centre to centre)Impedance (@1kHz): 230-280kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-6x10-500-3D

Substrate dimension: 15mm x 15mm x 0.5mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: 3D tip-shapedElectrode height: 70-80µm

Recording electrodes: 60Reference electrode: External reference to be used

Electrode layout: 6x10 matrixElectrodes dimension: Ø75µmInterelectrode distance: 500µm (centre to centre)Impedance (@1kHz): 150-250kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-6x10-600

Substrate dimension: 15mm x 15mm x 0.7mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: Planar

Recording electrodes: 60Reference electrode: external reference to be used

Electrode layout: 6x10 matrixElectrodes dimension: Ø80µmInterelectrode distance: 600µm (centre to centre)Impedance (@1kHz): 200-250kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Dissociated cell cultures (brain tissue, spinal cord, retina,heart muscle cells, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com

MEA60-6x10-600-3D

Substrate dimension: 15mm x 15mm x 0.5mmSubstrate material: GlassElectrode material: PlatinumInsulation material: SU-8 epoxy, thickness 5µmWorking Temperature: 10°C - 70°C

Electrode geometry: 3D tip-shapedElectrode height: 70-80µm

Recording electrodes: 60Reference electrode: External reference to be used

Electrode layout: 6x10 matrixElectrodes dimension: Ø80µmInterelectrode distance: 600µm (centre to centre)Impedance (@1kHz): 100-200kΩ

Culture chamber: Glass ringExternal Ø24mm, height 6mm

Required accessory: MEA60-Spacer

Characteristics

Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)

Applications

Product typeMicro-Electrode Array Biochip compatible with the dataacquisition systems from Multi Channel Systems MCSGmbH, Reutlingen, Germany.

Product information is subject to change without notice

© 2019, Marc Heuschkel

Marc Heuschkel, Ch. de Champ Petau 2, CH-1053 Bretigny, SwitzerlandEmail: [email protected], Internet: www.qwane.com