MDT-ASD PRR
C. Posch 1 30-Aug-01
Radiation Hardness Assurance
Total Ionizing Dose (TID) Change of device (transistor) properties, permanent
Single Event Effects (SEE) Single Event Latchup (SEL), possibly destructive Single Event Upset (SEU), temporary (reset)
Non-Ionizing Energy Loss (NIEL) not relevant for pure CMOS processes
Types of radiation effects:
TID and SEE tests have been performed according to the ATLAS standard radiation test procedures.Additional data on the radiation hardness of the process exist from other sources
MDT-ASD PRR
C. Posch 2 30-Aug-01
Total Ionizing Dose (TID) test
Radiation Facility: Harvard Cyclotron 160 MeV proton beam, variable fluence up to 3·1010 p/sec Beam diameter adjustable from 0.1 cm to 30 cm
Beam Setup and dose calculation: 4.41·108 p/cm2 per Monitor Unit (MU) Ionizing dose in Silicon: 30.21 rad(Si)/MU. 2.38 MU/sec yields a dose rate of ~ 70 rad/sec.
DUT and total dose : 10 devices were irradiated to a TID of 302 krad 5 non-irradiated devices characterized for comparison
MDT-ASD PRR
C. Posch 3 30-Aug-01
TID test setup
Online monitored DC parameters: On-chip bias generator voltages Pre-amp input levels LVDS output levels Power consumption
All values are displayed on screen for immediate observation and are also recorded with the proper timing information for offline analysis
During irradiation the DUT is biased and run under its nominal operating conditions, however there are no signals passed through the analog
amplifier chain. The digital part is exercised periodically
MDT-ASD PRR
C. Posch 4 30-Aug-01
Results - DC parameters (I)
Bias generator - DC levels: average all chips
0.5
0.75
1
1.25
1.5
1.75
2
2.25
2.5
0 50 100 150 200 250 300
Si dose [krad]
DC
vo
ltag
es
Vb4 Vb3Vb2 Vb1Vb4sim Vb3simVb2sim Vb1sim
Preamp inputs - average all chips
0.66
0.67
0.68
0.69
0.7
0.71
0.72
0.73
0.74
0 50 100 150 200 250 300
Si dose [krad]
DC
vo
ltag
es
InA0InA1InB0InB1
The observed changes in DC parameters appeared very similar on all of 10 irradiated devices so only the averages across all DUTs are plotted.
•Pre-amp bias voltages dropped between 2% (Vb4) and 5% (Vb3)•Pre-amp input DC levels dropped by 3% - 4%.
MDT-ASD PRR
C. Posch 5 30-Aug-01
Results - DC parameters (II)
LVDS outputs - average all chips
1.05
1.1
1.15
1.2
1.25
1.3
1.35
1.4
0 50 100 150 200 250 300
Si dose [krad]
DC
vo
ltag
es OutA0OutA2OutB0OutB2
Supply current - Idd (chip 5 - 10)
0.045
0.048
0.051
0.054
0.057
0.06
0 50 100 150 200 250 300
Si dose [krad]
Idd
[A
]
•The DC levels of the LVDS output drivers drop 2% - 3%
•There was no measurable increase in power consumption - no noticeable radiation induced leakage current increase occurred
MDT-ASD PRR
C. Posch 6 30-Aug-01
Results - Performance Parameters
Parameter MAX change AVG(input charge) change System context/commentWilkinson pulse width 0 0 Wilkinson width jitter + 146 ps r.m.s. + 93 ps r.m.s. < 0.1% of typical pulseRMS timing error + 45 ps r.m.s. + 28 ps r.m.s. 3.5% of TDC bin widthAmplifier gain 26 mV peak 15 mV peak minus 5%RMS noise 0 0 Shaper peaking time 161 ps 153 ps minus 0.1%
500
400
300
200
100
pe
ak
[mV
]
87654321input charge [arb U]
Vout vs. Qin
300 krad Pre
1.0
0.8
0.6
0.4
0.2
0.0
(t
ime
) [n
s]
87654321input charge [arb U]
Timing noise vs. Qin
300 krad Pre
2.0
1.8
1.6
1.4
1.2
1.0
0.8
(w
idth
) [n
s]
87654321input charge [arb U]
Wilkinson noise vs. Qin
300 krad Pre
MDT-ASD PRR
C. Posch 7 30-Aug-01
Comparison to Gamma Radiation Data
Gamma irradiation of ASD00A at the CERN X-ray facility30 keV gammasTID of 1 Mrad Steps: 10k, 50k, 100k, 300k, 1Mrad Dose rate: ~ 170 rad/sec
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
(t
ime
) [n
s]
5040302010input charge [arb U]
Timing noise vs. QinGamma iradiation 300 krad
300 krad Pre
1.0
0.8
0.6
0.4
0.2
0.0
(t
ime
) [n
s]
87654321input charge [arb U]
Timing noise vs. QinProton iradiation 300 krad
300 krad Pre
500
400
300
200
100
0
pe
ak
[mV
]
5040302010input charge [arb U]
Vout vs. QinGamma irradiation 300 krad
300 krad Pre
500
400
300
200
100
0
pea
k [m
V]
87654321input charge [arb U]
Vout vs. QinProton irradiation 300 krad
300 krad Pre
Parameter Gammas Protons
Wilk. jitter increase 118 ps 91 psTime error increase 25 ps 28 psAmp gain decrease 15.4 mV 15.3 mV
MDT-ASD PRR
C. Posch 8 30-Aug-01
Gamma TID results
110
100
90
80
70
60
ga
in [%
of p
rera
d]
12 3 4 5 6
102 3 4 5 6
1002 3 4 5 6
1000TID [krad]
99.25%
81.7%
Gain vs. TID0.34
0.33
0.32
0.31
0.30
0.29
0.28
(t
ime
) [n
s]
12 3 4 5 6
102 3 4 5 6
1002 3 4 5 6
1000TID [krad]
+ 15%
Timing noise vs. TID160
140
120
100
80
60
40
20
0
ana
log
out
put
pul
se p
ea
k [m
V a
rb]
70605040302010input charge [fC]
prerad 10 krad 50 krad 100 krad 300 krad 1 Mrad
Vout vs. Qin
The averaged RMS timing error increases by 7 % after 300 krad TID At the RTCtid for ASIC qualification, the RMS timing error increase is negligible The voltage gain of the complete analog signal chain - pre-amp, shaper (3 diff amps), analog pad driver drops by 5 % after 300 krad TID At RTCtid the gain drop of the full chain is of the order of 1 % The chip is fully functional after 1 Mrad with a gain drop of 18 % and a timing error increase of 15 %
MDT-ASD PRR
C. Posch 9 30-Aug-01
HP 0.5m CMOS process: TID tolerance
“Total Dose Hardness …”:(Osborne et. al., IEEE Trans. Nucl. Sci., 1998)
“The best TID radiation tolerance is achieved in the HP 0.5m process. The average change in threshold voltage at 100 krad is less than 40 mV for the n-channel and less than 20 mV for the p-channel devices.” “The HP 0.5 m process appears to be a candidate for missions with a total dose requirement of 100 krad.”
(Paul O`Connor, BNL, 1999)
CSC-ASD (similar circuit), 60Co irradiation
Results (1 Mrad):
increase in supply current negligible, almost no radiation induced leakage current.
Gain drop: 4.06 -> 3.99 mV/fC (- 1.5 %)
Noise increase: 1750 -> 2050 rms e- ENC (+ 17 %)
No wave-form change
MDT-ASD PRR
C. Posch 10
30-Aug-01
Single Event Effect (SEE) test
Radiation Facility: Harvard Cyclotron 160 MeV proton beam
Beam Setup and Fluence: 1.05·109 p ·cm-2 ·s-1
1.7 cm beam diameter 10 devices up to a fluence 4.4·1012 p·cm-2 per device Total fluence 4.46·1013 p·cm-2
• For Single Event Upset (SEU) monitoring the test system periodically reads all on-chip register contents, compares them to an initial state and re-writes the registers.
• Every bit flip is recorded and time stamped. The period of this read-write cycle is approximately 3 seconds.
• The power consumption of the DUT is monitored to catch Single Event Latchups (SEL). • During irradiation the DUT is biased and run under its nominal operating conditions, however
there are no signals passed through the analog amplifier chain.
MDT-ASD PRR
C. Posch 11
30-Aug-01
SEE Test Results
Chip ID # SEU Shift Reg bit Setup Reg bit at p/cm2 total p/cm2
1 2 39 92 2.64E+012 4.40E+0122 1 52 - 1.76E+011 4.61E+0123 0 - - - 4.40E+0124 0 - - - 4.76E+0125 2 46 99 1.76E+012 4.41E+0126 0 - - - 4.41E+0127 0 - - - 4.41E+0128 0 - - - 4.41E+0129 2 29 82 3.53E+012 4.41E+012
10 0 - - - 4.41E+012
Total SEU 7 Total fluence 4.46E+013
7 SEUs (bit flips) were observed after 4.46·1013 protons·cm-2
4 SEUs in the shift register, 3 SEUs in the setup register No hard/destructive SEEs (stuck bits, latch-ups) occurred
MDT-ASD PRR
C. Posch 12
30-Aug-01
SEU - impact calculation4.46·1013 p·cm-2 Total test fluence6.38·1012 p·cm-2 Average fluence per SEU (7)1.33·1012 h·cm-2 Fluence for 10 years ATLAS (SRLsee)
0.2086 Average SEU per device (10 years)46'000 Number of devices
9'595 Total SEU - all devices (10 years)959.5 SEU / year
4.80 SEU / day (assuming 200 days running)2.40 SEU / day (only setup register)~ 1 Worst case SEU / month
• Proton irradiation of 10 devices up to a total fluence of 4.46·1013 p·cm-2 yielded enough statistics to make a solid prediction on average fluence per SEE per device.
• The relevant numbers are 0.2 SEUs per device in 10 years and 2.4 SEUs per day for all of ATLAS. No hard/destructive SEE (e.g. latch-ups) occurred.
• The worst case impact of one SEU is the loss of 8 channels out of 360'000 for the time of one update interval.
• Occurence probability of 1 out of 53 SEUs or approximately once per month.• The SEU rate is very manageable and will not cause any considerable degradation in
performance of the ATLAS MDT detector.
MDT-ASD PRR
C. Posch 13
30-Aug-01
HP 0.5m CMOS process: SEL tolerance
“Single Event Latchup …”:(Osborn et. al.7th NASA Symposium
on VLSI design, 1998)
HP 0.5 Latchup Data
50
60
70
80
90
100
110
1 2 3 4 5
Drawn Well-to-active spacing [um]
LE
T [
Me
V/m
g/c
m^
2]
Conservative design rules: (MOSIS SCMOS)
Double Min. Well-to-Active spacing: Double Min. Well-to-Active spacing: 33m
81 LET latchup threshold
“A recent simulation study [Huthinen et al.] has shown that the maximum energy deposition occurring with non-negligible probability in the LHC radiation environment will correspond locally to a LET lower than 50 MeVcm2mg-1.”
(Extremely rare “worst-case” assumption)
MDT-ASD PRR
C. Posch 14
30-Aug-01
CMOS Latchup - Well-to-Active Spacing
Rwell
Rsub
Well-to-Active spacing33m
p-substrate
MDT-ASD PRR
C. Posch 15
30-Aug-01
ASD radiation tolerance: Summary
Total Ionizing Dose (TID) ASD fully functional after ionizing dose corresponding to 17 times
worst case RTC (1 DUT) and ~ 5 times RTC (10DUTs) No measurable increase in supply current radiation induced leakage
current insignificant Device parameter changes at expected maximum dose completely
negligible
Single Event Effects (SEE)Single Event Upset (SEU)
Worst case SEU expected at a rate of ~ 1 per month
Hard/destructive SEE:
No occurance
Single Event Latchup (SEL):
Process tested for SEL - critical LET not expected in LHC