Upload
hanyalramady
View
216
Download
0
Embed Size (px)
Citation preview
7/26/2019 MD Guardline Distribution System
1/32
Distribution SystemMCBs, RCCBs, Distribution Boards
Keeping you protected
7/26/2019 MD Guardline Distribution System
2/32
Warranty Policy :
Product offered by us are warranted against defects arising out of manufacturing processes or use of defective raw materials, for a period of
18 months from the date of supply or 12 months from the date of installation whichever is earlier. The company reserves the right to either replace
or repair the defective items after ascertaining the facts through a detailed service report on usage of our products in normal conditions. However,
MCB warranty is 3 years as standard and extends to 5 years in case used in GE make standard distribution boards.
The prices mentioned in the buylog for the same are for guidance purposes only. The products may be sold at lower prices also. Goods are always
sold subject to laws, rules and regulations relating to excise, customs and maximum retail price as applicable at the time of purchase and as printedon the goods. Excise duty is not applicable on Guardline MCB, however applicable on RCCBs and DBs.
7/26/2019 MD Guardline Distribution System
3/32
GE Energy - Industrial Solutions, India offers innovative
solutions to meet customer needs in Power & Protection.
The company has a pan India presence, with 4 regionaloffices, 9 branch offices and one manufacturing plant.
GE Energy, offers solutions to customers in several segments
that include power sector, core infrastructure like marine
establishments, airports, highways, heavy & light industries,
IT & ITES infrastructure, healthcare, commercial and
residential segments.
About GE Energy - Industrial Solutions
7/26/2019 MD Guardline Distribution System
4/32
7/26/2019 MD Guardline Distribution System
5/32
Contents
Guardline
Miniature Circuit Breakers
Safetrip
Residual Current Circuit Breakers
Safeline
Distribution Boards
Dimensions & Diagrams
A6
B10
C14
7/26/2019 MD Guardline Distribution System
6/32
GuardlineMiniature Circuit Breakers
Keeping you guarded
7/26/2019 MD Guardline Distribution System
7/32A7
Conforms to IS8828:96/IEC60898-1
0.5A to 63A, 10kA
Trip free mechanism
Disconnection with positive contact
Low watt loss Energy saving
Touch proof terminals IP20
High grade engineering plastic housing
ON-OFF flag indication
Captive terminal screws
Compatibility with all DBs
Rated Current(In) : 0.5A, 1A, 2A, 3A, 4A, 6A, 10A, 16A,
20A, 25A, 32A, 40A, 50A, 63A
Number of Poles : 1 Pole, 2 Pole, 3 Pole and 4 Pole
Breaking Capacity : 10kA
Rated Voltage : 240/415V AC
Insulation Voltage : 500V AC
Frequency : 50/60Hz
Tripping Characteristics* : C, D
Operating Temp Range : -250C to +550C
Mounting Arrangement : Snap on fixing, 35mm DIN Channel
Isolators : 40/63A in 2 Pole, 3 Pole and 4 Pole
Higher ratings on request*B series on request
Tripping Characterstics CurveType - B, C & D
Lower Limit as per Standard
Upper Limit as per Standard
Reference Calibration Temp. 40 Co
IS: 8828-1996/IEC-60898-1-2002
Limit Specified in
In : Rated Current
D Type - 0.5A to 63A
B Type - 0.5A to 63AC Type - 0.5A to 63A
1
Multiple of Rated Current
1.13 1.45 2 2.55 3 5 10 14 20 28 50
-B-Type- - C- Type- - D- Type-
TimeinSeconds
1000
100005000
3600
100
10
1
0.1
0.01
Salient Features Technical Details
7/26/2019 MD Guardline Distribution System
8/32
Single Pole
0.5
1
2
3
4
6
10
16
2025
32
40
50
63
Double Pole
0.5
1
2
3
4
6
10
16
20
25
32
40
50
63
Triple Pole
0.5
1
2
3
GLCSP00
GLCSP01
GLCSP02
GLCSP03
GLCSP04
GLCSP06
GLCSP10
GLCSP16
GLCSP20GLCSP25
GLCSP32
GLCSP40
GLCSP50
GLCSP63
GLCDP00
GLCDP01
GLCDP02
GLCDP03
GLCDP04
GLCDP06
GLCDP10
GLCDP16
GLCDP20
GLCDP25
GLCDP32
GLCDP40
GLCDP50
GLCDP63
GLCTP00
GLCTP01
GLCTP02
GLCTP03
GLDSP00
GLDSP01
GLDSP02
GLDSP03
GLDSP04
GLDSP06
GLDSP10
GLDSP16
GLDSP20GLDSP25
GLDSP32
GLDSP40
GLDSP50
GLDSP63
GLDDP00
GLDDP01
GLDDP02
GLDDP03
GLDDP04
GLDDP06
GLDDP10
GLDDP16
GLDDP20
GLDDP25
GLDDP32
GLDDP40
GLDDP50
GLDDP63
GLDTP00
GLDTP01
GLDTP02
GLDTP03
1212
12
12
12
12
12
12
1212
12
12
12
12
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4
4
4
4
Guardline Ordering Codes
Current Rating(A)
Ordering Cat.No.Type C
Ordering Cat.No.Type D
StandardPack Qty
A8
7/26/2019 MD Guardline Distribution System
9/32
Current Rating(A)
Ordering Cat.No.Type C
Ordering Cat.No.Type D
StandardPack Qty
Current Rating
For marked MCBs please contact your nearest GE sales office
Poles
40 Double Pole GLISDP40
63 Double Pole GLISDP63
40 Triple Pole GLISTP40
63 Triple Pole GLISTP63
40 Four Pole GLISFP40
63 Four Pole GLISFP63
GLCTP04
GLCTP06
GLCTP10
GLCTP16
GLCTP20
GLCTP25
GLCTP32
GLCTP40
GLCTP50
GLCTP63
GLCFP00
GLCFP01
GLCFP02
GLCFP03
GLCFP04
GLCFP06
GLCFP10
GLCFP16
GLCFP20
GLCFP25
GLCFP32
GLCFP40
GLCFP50
GLCFP63
GLDTP04
GLDTP06
GLDTP10
GLDTP16
GLDTP20
GLDTP25
GLDTP32
GLDTP40
GLDTP50
GLDTP63
GLDFP00
GLDFP01
GLDFP02
GLDFP03
GLDFP04
GLDFP06
GLDFP10
GLDFP16
GLDFP20
GLDFP25
GLDFP32
GLDFP40
GLDFP50
GLDFP63
4
4
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
3
3
3
3
3
3
A9
Isolator
4
6
10
16
20
25
32
40
50
63Four Pole
0.5
1
2
3
4
6
10
16
20
25
32
40
50
63
Ordering Cat.No.
7/26/2019 MD Guardline Distribution System
10/32
SafetripResidual Current Circuit Breakers
Keeping you safe
7/26/2019 MD Guardline Distribution System
11/32
B11
Personal protection - Against electrocution
The use of exposed, substandard and poorly wired, or damaged
equipment reduces the safety of an installation and increases the
risk of an electric shock to the person in contact. Electrocution is a
passage of current flowing through human body which affects
the vital functioning like breathing and heartbeat. This can be verydangerous to the person in contact depending upon current and
time for which it flows.
A correctly selected RCCB can detect even small currents flowing
to earth and reduces the risk of electrocution. The effect of electric
current through human body has been well researched and is as
below.
500mA Immediate cardiac arrest resulting in death
70-100mA Cardiac fibrillation; the heart begins to
vibrate and no longer beats at a steady rate
This situation is dangerous since it is
irreversible
20-30mA Muscle contraction can cause respiratory
paralysis
10mA Muscle contraction: the person remains stuck to
the conductor
1-10mA Prickling sensations
Salient Features Technical Details
Conforms to IEC61008-1
2 Pole & 4 Pole
Trip free mechanism
Disconnection with positive contact
Antiwelding contacts
Bi-connect facility
Touch proof terminals IP20
Resistance against unwanted tripping
Test facility - A test button T provided on device
No ageing effect
Compatibility with all DBs
Protection
Rated Current(In) : 25A, 40A, 63A
Sensitivity* : 30mA, 100mA, 300mA
Number of Poles : 2 Pole and 4 Pole
Rated Voltage : 240/415V AC
Insulation Voltage : 500V AC
Frequency : 50/60Hz
Operating Temp. Range : -250C to +600C
Terminal Capacity : 25mm2
Mounting Arrangement : 35mm DIN Channel
Service Life : 20000 operations
Optional Accessories : Aux. contact, shunt & undervoltage
release, motor operator & panelboard switch
*500mA sensitivity available on request for industrial applications
7/26/2019 MD Guardline Distribution System
12/32
B12
1 Usually has no reactions or effects.
2 Usually has no harmful effects.
3 Usually, no organic damage is expected.
Here the likelihood present is of muscular contractions and difficulty in breathing. Reversible disturbances in
the formation and conductance of impulses in the
heart , including arterial fibrillation and transient
cardiac arrest without ventricular fibrillation are
possible. These effects increase with current
magnitude and time.
4 In addition to the effects of Zone 3, the probability of
ventricular fibrillation increases from 5% (curve c2),
to about 50% (curve c3) and beyond 50% above
(curve c3). Increasing with magnitude and time are
pathophysiological effects as cardiac and breathing
arrest, whilst heavy burns are possible.
However, electrocution should not be viewed in terms of current alone but in
terms of contact voltage. A person gets electrocuted by coming in contact
with an object that has a different potential from his/her own. The difference in
potential causes the current to flow through the body.
The human body has known limits:
In a dry environment, voltage limit = 50V
In a humid environment, voltage limit = 25V
Over current protection devices like MCB are unable to act
promptly on small earth leakage currents. To comply with wiring
regulations the earth fault loop impedance in Ohms, multiplied
by the rated tripping current of the RCD in amperes must not
exceed 50.
Against Indirect Contact Zone Physiological effects
The majority of fires in an electrical installation are result of
leakage current flowing to earth and even a current of the order
of 1A can lead to big fire. These type of faults are not detected by
the normal short circuit protection device like MCB or Fuse. A
correctly selected RCCB will detect this leakage and save the risk
of fire saving the installation.
Against Fire
7/26/2019 MD Guardline Distribution System
13/32
B13
Selection
30mA -This RCCB will provide a high degree of protection against
electrocution. The current flowing through human body depends
upon the resistance of human body and voltage across it and can
vary between 80mA to 240mA. To be within zone of the IEC curve
as shown in chart. It is necessary for the RCCB to operate within
50ms at 240mA and 150ms at 80mA. Both these conditions are
satisfied by 30mA RCCB. For households, individual loads, damp
areas and construction installations, RCCB with sensitivity not
exceeding 30mA is recommended.
100mA -This RCCB will normally give high degree of protection
against electrocution but there is a possibility that the shock
current could fall below the tripping level of RCCB. This could occur
if additional resistances to that of human body are included in the
earth path. The 100mA RCCB protects against leakage currents
and indirect contact with earth loop impedance upto 500 Ohms.
300mA -This RCCB may be used where only fire protection is
required. eg., on lighting circuits and larger installations. These will
not give any protection against electrocution.
Amps Poles Sensitivity (mA) Sensitivity (mA)
Rating at 240V/415V AC Rating at 240V AC
Safetrip RCCB offering
Poles
25
40
63
25
40
63
25
40
63
4
4
4
4
4
4
4
4
4
30
30
30
100
100
100
300
300
300
2
2
2
2
2
2
2
2
2
30
30
30
100
100
100
300
300
300
7/26/2019 MD Guardline Distribution System
14/32
SafelineDistribution Boards
Keeping you secure
7/26/2019 MD Guardline Distribution System
15/32
C15
Aesthetically designed in compliance with latest standards
Wide range-sheet steel DBs upto 18 ways
SPN, TPN in single & double door
Degree of protection IP30, IP42 & IP43
Surface & flush mounting
Powder coated Corrosion & scratch resistance
Detachable gland plate
Adequate knock-outs on all sides
Generous wiring space
Clear circuit identification
Supplied complete with bus bars, earth & neutral bars
Multitier, phase segregated, 7 segments, vertical DBs Plug & sockets boards
Prewired DBs available on request Please contact your nearest GE Sales Office
Voltage : 240V AC for SPN, 415V for
TP/TPN DBs
Standard Busbar Rating : 63A/100A/125A
No. of Ways : 4, 6, 8, 10, 12, 14, 18 ways
Mounting : Surface/FlushDielectric Strength : 2.5kV RMS AC for 1min
Mounting Arrangement : 35mm DIN Rail for MCBs, RCCBs
Salient Features Technical Details
7/26/2019 MD Guardline Distribution System
16/32
C16
Plane enclosures 1, 2, 3, 4, 5, 6, 8 ways
IP30 pole incomer
Salient Features
Technical Details
DescriptionCode Ref.
Single Door
1Way SLEMS0001Y
2Way SLEMS0002Y
3Way SLEMS0003Y
4Way SLEMS0004Y
6Way SLEMS0006Y
8Way SLEMS0008Y
Blanking Plate
1Way SLMBP0001X
Dimensions & Diagram - 1.1 | Page D28
One Way Enclosures
One Way Enclosures
7/26/2019 MD Guardline Distribution System
17/32
C17
Safe line - Sheet steel - SPN SPN version in 4, 6, 8, 10, 12, 14, 16 and 18 ways outgoing
Single door, double door and acrylic door
IP30, IP42 and IP43 protection
Liberal wiring space, adequate cable glands
Superior powder coated finish for better protection against heat
& dust (Powder coating thickness of more than 60 microns)
Detachable gland plates
Complete with phase busbars, earthbars, neutral bars & cable kit
Salient Features
Technical Details
DescriptionCode Ref. Code Ref. Code Ref.
Single Door Double Door Acrylic Door
Dimensions4Way SLSMS0204Y SLSMD0204Y 6Way SLSMS0206Y SLSMD0206Y SLSMA0206Y
8Way SLSMS0208Y SLSMD0208Y SLSMA0208Y
10Way SLSMS0210Y SLSMD0210Y SLSMA0210Y
12Way SLSMS0212Y SLSMD0212Y SLSMA0212Y
14Way SLSMS0214Y SLSMD0214Y SLSMA0214Y
16Way SLSMS0216Y SLSMD0216Y SLSMA0216Y
18Way SLSMS0218Y SLSMD0218Y SLSMA0218Y0
Dimensions & Diagram - 1.2 | Page D28
SPN Distribution Boards
SPN Distribution Boards
7/26/2019 MD Guardline Distribution System
18/32
C18
4, 6, 8 and 12 ways Single door, double door and acrylic door (IP30, IP42 and IP43)
With provision 8 module incomer and SP MCB as outgoing
With copper busbar, neutral link, earth link
Supplied with wire set
Salient Features
Technical Details
DescriptionCode Ref. Code Ref. Code Ref.
Single Door Double Door
4Way SLTMS0804Y SLTMD0804Y SLTMA0804Y
6Way SLTMS0806Y SLTMD0806Y SLTMA0806Y
8Way SLTMS0808Y SLTMD0808Y SLTMA0808Y
12Way SLTMS0812Y SLTMD0812Y SLTMA0812Y
Acrylic Door
Dimensions & Diagram - 1.3 | Page D28
TPN Distribution Boards
TPN Distribution Boards
7/26/2019 MD Guardline Distribution System
19/32
C19
Suitable for flush mounting and surface mounting IP30, IP42 and IP43 protection
Detachable gland plates
With copper bus bar
Suitable for 8 module incomer and DP RCCB/RCBO as
sub incomer and SP MCBs as outgoing
3 separate mutual link for each phase
With neutral link and earth bar
6, 8, 12, 16 ways
Salient Features
Technical Details :With four neutral links, one earth link, excluding bus bars and interconnections
DescriptionCode Ref. Code Ref.
Single Door Double Door
6Way 8+4+2 SLHMS0806Y SLHMD0806Y
8Way 8+6+2 SLHMS0808Y SLHMD0808Y
12Way 8+10+2 SLHMS0812Y SLHMD0812Y
16Way 8+14+2 SLHMS0816Y SLHMD0816Y
Dimensions & Diagram - 1.4 | Page D28
Per Phase Isolation Horizontal Distribution Boards
Per Phase IsolationHorizontal Distribution Boards
7/26/2019 MD Guardline Distribution System
20/32
IP30, IP42 and IP43 protection With 8 cutting incomer and 3 rows with different
configuration
Separate neutral for each phase
SP and TP outgoing are possible
Sub incomer of 2 Pole
Salient Features
Single Door
Technical Details :With four neutral links, one earth link, excluding bus bars and interconnections.
DescriptionCode Ref. Code Ref.
Double Door Acrylic Door
8 Way (3 Rowx8+1 Rowx8) SLIMD0808Y SLIMA0808Y
10 Way (3 Rowx10+1 Rowx8) SLIMD0810Y SLIMA0810Y
12 Way (3 Rowx12+1 Rowx8) SLIMD0812Y SLIMA0812Y
14 Way (3 Rowx14+1 Rowx8) SLIMD0814Y SLIMA0814Y
16 Way (3 Rowx16+1 Rowx8) SLIMD0816Y SLIMA0816Y
Dimensions & Diagram - 1.5 | Page D29
Per Phase Isolation Vertical Distribution Boards
C20
Per Phase IsolationVertical Distribution Boards
7/26/2019 MD Guardline Distribution System
21/32
IP30, IP42 and IP43 protection With MCB and 49 RCCB incomer (4 Pole)
TP and SP outgoing
IP30 and IP43
With copper bus bar
Spectra range MCCB upto 125A and Record range for
higher rating
Salient Features
Technical Details - Provision for 4Pole MCB/RCCB
DescriptionCode Ref. Code Ref. Code Ref.
Single Door Double Door Acrylic Door
4Way SLVMS0804Y SLVMD0804Y SLVMA0804Y
6Way SLVMS0806Y SLVMD0806Y SLVMA0806Y
8Way SLVMS0808Y SLVMD0808Y SLVMA0808Y
12Way SLVMS0812Y SLVMD0812Y SLVMA0812Y
Dimensions & Diagram - 1.6 | Page D29
TPN Vertical Distribution Boards
C21
TPN Vertical Distribution Boards
7/26/2019 MD Guardline Distribution System
22/32
C22
Suitable for flush mounting and surface mounting IP30, IP42 and IP43 protection
Detachable gland plates
With copper bus bar
With neutral bar and earth bar
Pan assembly for ease of installation
With provisions for Spectra / Record Range MCCB
as incomer and SP/TP MCBs as outgoing
4, 6, 8 and 12 ways
Salient Features
Technical Details - Provision for 4Pole MCB/RCCB
DescriptionCode Ref. Code Ref.
Double Door - 100A Double Door - 225A
4Way SLVMDM04Y SLVMDM204Y
6Way SLVMDM06Y SLVMDM206Y
8Way SLVMDM08Y SLVMDM208Y
12Way SLVMDM12Y SLVMDM212Y
Dimensions & Diagram - 1.7 | Page D29
TPN Vertical Distribution Boards with MCCB Incomer
TPN Vertical Distribution Boardswith MCCB Incomer
7/26/2019 MD Guardline Distribution System
23/32
C23
With provision for 3nos. phase selector switches and in-built
piano switches
Suitable for flush mounting and surface mounting
IP30, IP42 and IP43 protection
Detachable gland plates
With copper bus bar
With neutral bar, earth bar, and wire set
With provision for 8 module incomer and SP MCB, as outgoing
4, 6, 8 and 12 ways
Salient Features
Technical Details - TPN phase selector DB with 3nos. piano switch
DescriptionCode Ref. Code Ref.
Single Door Double Door
4Way SLXMS0804Y SLXMD0804Y
6Way SLXMS0806Y SLXMD0806Y
8Way SLXMS0808Y SLXMD0808Y
12Way SLXMS0812Y SLXMD0812Y
Dimensions & Diagram - 1.8 | Page D29
Phase Selector Distribution Boards
Phase Selector Distribution Boards
7/26/2019 MD Guardline Distribution System
24/32
DB with phase segregation and separator between incomer
and outgoing
Suitable for flush mounting and surface mounting
IP30, IP42 and IP43 protection
Detachable gland plates
With copper bus bar
With neutral bar, earth bar
With provision for 8 module incomer and DP RCCB/RCBO as
sub incomer and SP MCB, as outgoing
4, 6, 8 and 12 ways
Salient Features
C24
Technical Details - Compartmental space for 4P MCB
DescriptionCode Ref. Code Ref.
Single Door Double Door
4Way SLCMS0804Y SLCMD0804Y
6Way SLCMS0806Y SLCMD0806Y
8Way SLCMS0808Y SLCMD0808Y
12Way SLCMS0812Y SLCMD0812Y
Dimensions & Diagram - 1.9 | Page D30
Phase Segregated Distribution Boards
Phase Segregated Distribution Boards
7/26/2019 MD Guardline Distribution System
25/32
Suitable for flush mounting and surface mounting
IP30, IP42 and IP43 protection
Detachable gland plates
Flexibility to organize the distribution as per site requirements
With neutral bar and earth bar
26, 28, 39, 42, 52, 56 ways in 2, 3 and 4 rows
Other configurations on request
C25
Salient Features
Technical Details
DescriptionCode Ref. Code Ref.
Double Door Acrylic Door
13module x 2 tier SLFMD0213Y SLFMA0213Y
13module x 3 tier SLFMD0313Y SLFMA0313Y
13module x 4 tier SLFMD0413Y SLFMA0413Y
14module x 2 tier SLFMD0214Y SLFMA0214Y
14module x 3 tier SLFMD0314Y SLFMA0314Y
14module x 4 tier SLFMD0414Y SLFMA0414Y
Dimensions & Diagram - 1.10 | Page D30
Universal Distribution Boards
Universal Distribution Boards
7/26/2019 MD Guardline Distribution System
26/32
C26
SPN and TPN Distribution Boards
With in-built plug and socket
Ideal for protection of appliances like ACs, Geysers etc.
Available from 20A SPN to 63A TPN
Available for DP RCCB incomer
Excellent aesthetics
Salient Features
Technical Details
DescriptionCode Ref.
Single Door
20A SPN SLRMS0S20Y
20A TPN SLRMS0T20Y
32A TPN SLRMS0T32Y
20A with provision for DP RCCB SLRMS0220Y
32A TP with provision for 4P RCCB SLRMS0432Y
63A TP with provision for 3P MCB SLRMS0363Y
Dimensions & Diagram - 1.11 | Page D30
Plug & Socket Boards
Plug & Socket Boards
7/26/2019 MD Guardline Distribution System
27/32
Dimensions & DiagramPlease contact your nearest GE sales office for drawings in printable format
7/26/2019 MD Guardline Distribution System
28/32
D28
Dimensions & Diagram - 1.1
One Way Enclosures
Dimensions & Diagram - 1.2
SPN Distribution Boards
Dimensions & Diagram - 1.4
Per Phase Isolation Horizontal Distribution Boards
Dimensions & Diagram - 1.3
TPN Distribution Boards
245
105
225
47
0
340
450
7/26/2019 MD Guardline Distribution System
29/32
D29
Dimensions & Diagram - 1.6
TPN Vertical Distribution Boards
Dimensions & Diagram - 1.7
TPN Vertical Distribution Boards with MCCB Incomer
Dimensions & Diagram - 1.5
Per Phase Isolation Vertical Distribution Boards
Dimensions & Diagram - 1.8
Phase Selector Distribution Boards
7/26/2019 MD Guardline Distribution System
30/32
D30
Dimensions & Diagram - 1.9
Phase Segregated Distribution Boards
Dimensions & Diagram - 1.11
Plug & Socket Boards
Dimensions:
168x137x60
275x135x65
275x135x65
235x180x65
275x180x65
317x140x127
Dimensions & Diagram - 1.10
Universal Distribution Boards
168
137
78
60
5
5124
110
155
7/26/2019 MD Guardline Distribution System
31/32
Note :
Product upgradation is a continuous process. The data given is subject to change without any prior notice.
Please contact your nearest GE Sales office for the latest product information.
REGIONAL OFFICES BRANCH OFFICES
7/26/2019 MD Guardline Distribution System
32/32
NORTH
New Delhi
GE India Industrial Pvt. Ltd.71/1, Shivaji MargNew Delhi-110015Ph: (011) 45052277/8Fax: (011) 25928088
Chandigarh
GE India Industrial Pvt. Ltd.SCO No. 72 & 73, First FloorSector 8/C, Madhya MargChandigarh-160008Ph: (0172) 3982908-10Fax: (0172) 3982905
Jaipur
GE India Industrial Pvt. Ltd.448, 4th Floor, Ganapati PlazaM.I. Road, Jaipur-302001Ph: (0141) 5112802Fax: (0141) 2389012
Lucknow
GE India Industrial Pvt. Ltd.101, Ace Business Center19, Vidhan Sabha MargLucknow-226001Ph: (0522) 3203808, 3012444/666Fax: (0522) 4045909
SOUTH
Bangalore
GE India Industrial Pvt. Ltd.The Millenia, Level-6, Tower B1 & 2, Murphy Road, UlsoorBangalore-560008Ph: (080) 41434000Fax: (080) 41434199
Chennai
GE India Industrial Pvt. Ltd.Temple Tower, 6th Floor476, (New No. 672) Anna SalaiNandanamChennai-600035Ph: (044) 45070470-84Fax: (044) 45070474
Coimbatore
GE India Industrial Pvt. Ltd.No.36/6 & 7, 1st FloorAshirwad BuildingD.B.Road, R.S. PuramCoimbatore-641002Ph: (0422) 4393520 / 4393529
WEST
Mumbai
GE India Industrial Pvt. Ltd.361/362, Solitaire Corporate ParkM. Vasanji Road, ChakalaAndheri (E), Mumbai-400093Ph: (022) 40101610Fax: (022) 40101611
EAST
Kolkata
GE India Industrial Pvt. Ltd.Horizon Building, 4th Floor57, Chowringhee RoadKolkata-700071
Ph: (033) 40034056Fax: (033) 40034071
Works:GE India Industrial Pvt. Ltd.Plot No. 42/1 & 45/14Electronic City - Phase IIBangalore-560100Ph: (080) 41113000Fax: (080) 28528469/552
HO:GE India Industrial Pvt. Ltd.The Millenia, Level-6, Tower B1 & 2, Murphy Road, UlsoorBangalore-560008Ph: (080) 41434000Fax: (080) 41434199Email: [email protected]
Toll Free No:18001024343
Customer Care:[email protected]
We are committed to continuous development and improvement of our products and the specifications aresubject to change without notice. For product availability and latest prices, please contact GE Sales Team.
For any further information, visit us at http://www.geindustrial.com
gand General Electric are registered trade marks of General Electric Co. USA
Ahmedabad
GE India Industrial Pvt. Ltd.405-406, Kirtiman ComplexKinariwala House, Behind CitibankOff C.G. Road, Ahmedabad-380006Ph: (079) 65427385/55427389Fax: (079) 26460637
Pune
GE Money Financial Services LimitedShop No. 405-410, 4th FloorCity Point, Dhole Patil RoadPune-411001Mob: +91 9850867507
Cochin
GE India Industrial Pvt. Ltd.Mayur Business Center & MotelChittur Road, Pullepadi JunctionCochin-682035Ph: (0484) 2364139Fax: (0484) 4031400
Hyderabad
GE India Industrial Pvt. Ltd.5-2-45, Hyderbasti, RP RoadNear Gujarati High SchoolSecunderabad-500003Ph: (040) 27543162, 66311264Fax: (040) 66339272
1
107/MODGLMCB