mcq-engineering.blogspot.com http://mcq-engineering.blogspot.com/2013/01/power-systems-dc-transmission-and.html?pfstyle=wp Power Systems (DC Transmission and Distribution) 1. If in a d.c. 2-wire feeder, drop per feeder conductor is 2%, transmission efficiency of the feeder is ........................... percent. (a) 98 (b) 94 (c) 96 (d) 99 2. Transmitted power remaining the same, if supply voltage of a dc 2-wire feeder is increased by 100 percent, saving in copper is .......................... percent. (a) 50 (b) 25 (c) 100 (d) 75 3. A uniformly-loaded d.c. distributor is fed at both ends with equal voltages. As compared to a similar distributor fed at one end only, the drop at middle point is (a) one-half (b) one-fourth (c) one-third (d) twice. 4. In a d.c. 3-wire distributor using balancers and having unequal loads on the two sides (a) both balancers run as motors (b) both balancers run as generators (c) balancer connected to heavily-loaded side runs as a motor (d) balancer connected to lightly-loaded side runs as a motor. 5. As compared to a dc 2-wire distributor, a 3-wire distributor with same maximum voltage to earth uses only ...................... percent of copper. (a) 66.7 (b) 33.3 (c) 31.25 (d) 150 6. In a d.c. 3-wire distribution system, balancer fields are cross-connected in order to (a) make both machines run as unloaded motors. (b) equalize voltages on the positive and negative outers (c) boost the generated voltage (d) balance loads on both sides of the neutral. Answers 1. (c) 2. (a) 3. (b) 4. (d) 5. (c) 6. (a)

Mcq-Engineering-Power Systems DC Transmission and Distribution

Embed Size (px)

DESCRIPTION

Mcq-Engineering-Power Systems DC Transmission and Distribution

Citation preview

  • mcq-engineering.blogspot.comhttp://mcq-engineering.blogspot.com/2013/01/power-systems-dc-transmission-and.html?pfstyle=wp

    Power Systems (DC Transmission and Distribution)1. If in a d.c. 2-wire feeder, drop per feeder conductor is 2%, transmission efficiency ofthe feeder is ........................... percent.(a) 98(b) 94(c) 96(d) 99

    2. Transmitted power remaining the same, if supply voltage of a dc 2-wire feeder is increased by 100 percent,saving in copper is .......................... percent.(a) 50(b) 25(c) 100(d) 75

    3. A uniformly-loaded d.c. distributor is fed at both ends with equal voltages. As comparedto a similar distributor fed at one end only, the drop at middle point is(a) one-half(b) one-fourth(c) one-third(d) twice.

    4. In a d.c. 3-wire distributor using balancers and having unequal loads on the two sides(a) both balancers run as motors(b) both balancers run as generators(c) balancer connected to heavily-loaded side runs as a motor(d) balancer connected to lightly-loaded side runs as a motor.

    5. As compared to a dc 2-wire distributor, a 3-wire distributor with same maximum voltageto earth uses only...................... percent of copper.(a) 66.7(b) 33.3(c) 31.25(d) 150

    6. In a d.c. 3-wire distribution system, balancer fields are cross-connected in order to(a) make both machines run as unloaded motors.(b) equalize voltages on the positive and negative outers(c) boost the generated voltage(d) balance loads on both sides of the neutral.

    Answers1. (c) 2. (a) 3. (b) 4. (d) 5. (c) 6. (a)