Upload
eugenia-sanders
View
214
Download
0
Embed Size (px)
Citation preview
MC Type-B fit up review 1
Review of MC Type B assembly clearances reviewing A-to-B and
B-to-C interfaces
3/1/07
Summary:
Wing interfaces look okay between A/B and B/C. There is clamp interferences between A/B (see slide 3) and between B/C (see slide 11 and 12).
3
Type A
Section Cut Looking Inboard
Top
Type B
0.162” clearance
These clamps have an interference
Hole # 59
Hole # 61
Type-A Type-B
Clamps on A and B where there is interference or close contact is
indicated. Clamp measured needed.
Hole # 58
Hole # 60
A-to-B Fit-up
See next slide for winding form interface.
4
0.374”Type A
TopType B
This will be a tight region. Metrology data of the winding form and winding in this area would be useful.
5
MC Type-A to Type-B large wing interface clearance is 0.378” at the edge in the CAD model.
Type-B wing
Type-A wing
Type-B
A side
6
MC Type-A to Type-B large wing pocket interface clearance is 0.358” in the CAD model.
Underside surface of Type-A shown in yellow.
7
MC Type-A to Type-B small wing pocket interface clearance is 0.445” in the CAD model.
Type-B, Side AType-A pocket
surface
9
Outside Wing Flange B Side
MC Type-C to Type-B interface clearance at wing flange B side edge is 0.272” in the CAD model located at the edge of the wing.
Interfacing Type-C surface
Only the edge indicated in the circle area needs to be measured. See next slide for further details.
10
MC Type-B to Type-C large wing interface surface clearance is 0.628” in the CAD model.
There area should be ample space for the interfacing surface.
11
Type-C
Type-B
0.247” shell clearance along this local region.
Rotated expanded view of area indicated.
This will be a tight region. It appears that the winding itself will fit okay (see next slide) although there is clamp problems
12
Ignoring the clamps their appears to be no winding interferences.
Type-C Clamp 61 and clamp hardware interferes with the Type-B winding and local cable.
Hole 61…I think!
Hole # 63
Hole # 65
15
0.50” clearance over most of this length.
Type-B Side A
Measurement needed along this local edge of the Type-B winding form.