www.carlon.com 234 Rigid Nonmetallic Conduit Fittings & Accessories Flat Sealing Washer Part No. Size Std. Ctn. Qty. E943DW 1 /2 125 E943EW 3 /4 125 E943FW 1 100 E943GW 1 1 /4 50 E943HW 1 1 /2 50 E943JW 2 25 Part No. Size Std. Ctn. Qty. LT9LD 1 /2 1200 LT9LE 3 /4 700 LT9LF 1 600 PVC Lock Nut HOLFORM nonmetallic concrete sleeve forms are the easy way to form holes in concrete. They install in seconds with nails, screws or staples and are easily removed. Concrete will not adhere to them. HOLFORMS are adjustable to any slab thickness. Where a waterproof termination is required into any enclosure (metallic or nonmetallic), install the neoprene washer over the threads of a terminal adapter before inserting into the enclosure. Use a standard locknut or threaded bushing to secure the assembly. Std. A B C D Part No. Size Ctn. Qty. Typical Typical Typical Typical E990D 1 /2 75 .852 .836 2.187 .718 E990E 3 /4 50 1.064 1.046 2.531 .781 Gasket included. HOLFORM Concrete Sleeves Min. Std. Std. O.D. Ctn. Ctn. Part No. A B Qty. Wt. (lbs.) E92CSH 1 1 /2 1 3 /4 20 3 E92CSJ 2 2 13 /32 25 6 E92CSL 3 3 13 /32 25 8 E92CSN 4 4 13 /32 18 8 E92CSP 5 5 13 /32 15 8 E92CSR 6 6 13 /32 12 8 Access Pull Elbows Pull Elbows Sleeves Washers Lock Nuts Conduit Bodies Part No. Size Vol. Cu. In. Std. Ctn. Qty. E970CD 1 /2 15.16 15 E970CE 3 /4 15.16 15 Type X with Cover Four knock-out type socket openings, 90° spacing. Available with 1 /2” or 3 /4” socket outlets. Includes cover and gasket. Supplied with 4 stainless steel cover screws. Diameter 4 1 /8", Thickness 1 /4". *Not designed for use with wiring devices or light fixtures. E32447 Except where noted by LR31146 Except where noted by †

MC 2 Electrical€¦ · 234 Rigid Nonmetallic Conduit – Fittings & Accessories Flat Sealing Washer Part No. Size Std. Ctn. Qty. E943DW 1/2 125 E943EW 3/4 125 E943FW 1 100

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MC 2 Electrical€¦ · 234  Rigid Nonmetallic Conduit – Fittings & Accessories Flat Sealing Washer Part No. Size Std. Ctn. Qty. E943DW 1/2 125 E943EW 3/4 125 E943FW 1 100

w w w . c a r l o n . c o m234

Rigid Nonmetallic Conduit – Fittings & Accessories

Flat Sealing Washer

Part No. Size Std. Ctn. Qty.

E943DW 1/2 125

E943EW 3/4 125

E943FW 1 100

E943GW 11/4 50

E943HW 11/2 50

E943JW 2 25

Part No. Size Std. Ctn. Qty.

LT9LD 1/2 1200

LT9LE 3/4 700

LT9LF 1 600

PVC Lock Nut

HOLFORM nonmetallic concretesleeve forms are the easy way toform holes in concrete. Theyinstall in seconds with nails,screws or staples and are easilyremoved. Concrete will notadhere to them. HOLFORMS areadjustable to any slab thickness.

Where a waterproof termination is required into anyenclosure (metallic or nonmetallic), install the neoprenewasher over the threads of a terminal adapter beforeinserting into the enclosure. Use a standard locknut orthreaded bushing to secure the assembly.

Std. A B C DPart No. Size Ctn. Qty. Typical Typical Typical Typical

E990D 1/2 75 .852 .836 2.187 .718

E990E 3/4 50 1.064 1.046 2.531 .781

Gasket included.

HOLFORM™

Concrete Sleeves

Min. Std. Std.O.D. Ctn. Ctn.

Part No. A B Qty. Wt. (lbs.)

E92CSH 11/2 13/4 20 3

E92CSJ 2 213/32 25 6

E92CSL 3 313/32 25 8

E92CSN 4 413/32 18 8

E92CSP 5 513/32 15 8

E92CSR 6 613/32 12 8

Access Pull Elbows

Pull Elbows

SleevesWashers

Lock Nuts

Conduit Bodies

Part No. Size Vol. Cu. In. Std. Ctn. Qty.E970CD 1/2 15.16 15E970CE 3/4 15.16 15

Type X withCoverFour knock-out type socket openings, 90° spacing. Availablewith 1/2” or 3/4” socket outlets.Includes cover and gasket.

Supplied with 4 stainless steel cover screws. Diameter 41/8", Thickness 1/4".*Not designed for use with wiring devices or light fixtures.

E32447Except where

noted by

LR31146Except where

noted by †

MC_5_Conduit 8/28/07 12:21 PM Page 234

Page 2: MC 2 Electrical€¦ · 234  Rigid Nonmetallic Conduit – Fittings & Accessories Flat Sealing Washer Part No. Size Std. Ctn. Qty. E943DW 1/2 125 E943EW 3/4 125 E943FW 1 100

w w w . c a r l o n . c o m 235

Rigid Nonmetallic Conduit – Conduit Bodies

Part Std. C Max. L2 L3 Max Max Max. Vol.No. Size Ctn. Qty. Typical L1 Typical H Q W Cu. In.E986D 1/2 25 11/16 45/16 37/32 31/16 15/16 111/32 11/2 4.0E986E 3/4 15 29/32 69/32 59/32 425/32 125/32 13/4 21/32 12.0E986F 1 10 29/32 69/32 59/32 425/32 125/32 13/4 21/32 12.0E986G 11/4 10 13/32 731/32 613/32 6 25/16 21/2 23/4 32.0E986H 11/2 10 13/32 731/32 613/32 6 25/16 21/2 23/4 32.0E986J 2 10 15/32 931/32 813/32 71/4 29/16 35/32 315/32 63.0E986K 21/2 4 15/8 147/8 131/4 1131/32 33/4 411/32 4 5/8 210.E986L 3 4 15/8 147/8 131/4 1131/32 33/4 411/32 4 5/8 210.E986M 31/2 4 125/32 1723/32 157/8 1417/64 47/16 511/32 521/32 390.E986N 4 4 125/32 1723/32 157/8 1417/64 47/16 511/32 521/32 390.

Conduit Bodies

Type LB

Part Std. Vol.No. Size Ctn. Qty. C L1 L2 Q W Cu. In.

E988D 1/2 25 11/16 45/16 31/2 111/32 11/2 4.0E988E 3/4 20 29/32 611/32 59/32 13/4 21/32 12.0E988F 1 10 29/32 611/32 59/32 13/4 21/32 12.0E988G 11/4 10 13/32 8 613/32 21/2 23/4 32.0E988H 11/2 10 13/32 8 613/32 21/2 23/4 32.0E988J 2 5 15/32 915/32 813/32 35/32 315/32 63.0

Type E

Part Std. C Max. L2 Max Max. Vol.No. Size Ctn. Qty. Typical L1 Typical Q W Cu. In.

E987D 1/2 25 11/16 411/16 31/2 111/32 11/2 4.0E987E-CAR 3/4 10 29/32 67/8 532/64 13/4 21/32 12.0E987F-CAR 1 10 29/32 67/8 59/32 13/4 21/32 12.0E987G 11/4 10 13/32 821/32 613/32 21/2 23/4 32.0E987H 11/2 10 13/32 821/32 613/32 21/2 23/4 32.0E987J 2 15 15/32 105/16 813/32 35/32 315/32 63.0

Type C

Part Std. C Max. L2 L3 Max. Max. Max. Vol.No. Size Ctn. Qty. Typical L1 Typical H Q W Cu. In.

E985D-CAR 1/2 10 11/16 45/16 37/32 31/16 15/16 111/32 11/2 4.0E985E-CAR 3/4 10 29/32 69/32 59/32 425/32 125/32 13/4 21/32 12.0E985F 1 10 29/32 69/32 59/32 425/32 125/32 13/4 21/32 12.0E985G 11/4 10 13/32 731/32 613/32 6 25/16 21/2 23/4 32.0E985H-CAR 11/2 5 13/32 731/32 613/32 6 25/16 21/2 23/4 32.0E985J 2 10 15/32 99/32 813/32 71/4 29/16 35/32 315/32 63.0

Type LR

Part Std. C Max. L2 L3 Max Max Max. Vol.No. Size Ctn.Qty. Typical L1 Typical H Q W Cu. In.

E983D-CAR 1/2 10 11/16 411/16 37/32 211/32 15/16 111/32 11/2 4.0E983E 3/4 15 29/32 67/8 59/32 47/16 125/32 13/4 21/32 12.0E983F 1 20 29/32 67/8 59/32 37/16 125/32 13/4 21/32 12.0E983G 11/4 10 13/32 821/32 613/32 421/64 25/16 21/2 23/4 32.0E983H 11/2 10 13/32 821/32 613/32 421/64 25/16 21/2 23/4 32.0E983J 2 10 15/32 105/16 813/32 55/32 29/16 35/32 315/16 63.0

Type T

Part Std. C Max. L2 L3 Max Max Max. Vol.No. Size Ctn. Qty. Typical L1 Typical H Q W Cu. In.

E984D-CAR 1/2 10 11/16 45/16 37/32 31/16 15/16 111/32 11/2 4.0E984E 3/4 20 29/32 69/32 59/32 425/32 125/32 13/4 21/32 12.0E984F-CAR 1 10 29/32 69/32 59/32 425/32 125/32 13/4 21/32 12.0E984G-CAR 11/4 5 13/32 731/32 613/32 6 25/16 21/2 23/4 32.0E984H 11/2 10 13/32 731/32 613/32 6 25/16 21/2 23/4 32.0E984J 2 10 15/32 99/32 813/32 71/4 29/16 35/32 315/32 63.0

Type LL

• Hubs are not threaded • Textured lids • Foam-in-place gasketE42728

Except where noted by

LR31146

MC_5_Conduit 8/28/07 12:21 PM Page 235