www.honeywell.com/security 800-15885V4 – Rev A – 08/2016 MAXPRO ® NVR HYBRID SE (Standard Edition) Hybrid Network Video Recorder Quick Install Guide Document 800-15885V4 – Rev A – 08/2016 Introduction Welcome to your new Honeywell MAXPRO ® NVR HYBRID SE. This guide helps you set up the NVR right out of the box. Before installing your NVR, please read this guide carefully. Note Translated Quick Install Guides can be accessed on your MAXPRO NVR unit after logging in, by clicking on Start menu Honeywell Quick Install Guides. Unpack Check that the items received match those listed on the order form and packing slip. The packing box should include, in addition to your NVR unit and this guide: Install the Hardware Mount the MAXPRO NVR HYBRID SE Unit Mount the NVR either on a flat surface or in a rack mount ears supplied. Connect the Hardware Rear Panel Not shown: Rack mount ears HDMI to DVI-D adapter MAXPRO NVR DDNS Installation Instructions RS485 adapter I/O connectors Recovery USB Flash Drive MAXPRO NVR Client Software (Single Site) and Server Software DVD (includes manuals) MAXPRO Viewer Multi-Site Viewing Software Kit (includes DVD and Getting Started Guide). Not shown. Note Other peripheral hardware (owner supplied) will also be needed for your installation (such as cameras, network PoE switch for the camera network, network switch for a client workstation network, a monitor, and an optional keyboard controller). To access the front LEDs and HDDs (hard drives), use the security key to unlock, then pull the front panel toward you. DVI HDMI Display Port Connect supplied keyboard and mouse before powering up the NVR. Connect up to 16 analog cameras to the Video Input connectors. Connect a local monitor to one of the monitor outputs. # Connector Connects to... 1 Power Switch 2 AC Power Electrical outlet 3 Video Inputs, Outputs (BNC) Analog cameras 4 Control Outputs 5 Alarm Inputs 6 VGA Port VGA monitor 7 DVI-D Port Monitor 8 Display Port Monitor 9 HDMI Port HDMI monitor 10 LAN1 - Camera Network Port Network 11 USB Ports (x4) Various devices 12 LAN2 - Client/Workstation Network Port Network 13 S/PDIF (Optical) Not supported 14-18 Audio Inputs and Outputs Line in - line level Speaker out Microphone in - not used 19 RCA Connector Sport monitor (RCA) 20 Video Out Port 1–8 Analog camera looping output 21 Video Out Port 9–16 Analog camera looping output 22 RS485 PTZ device * * An analog PTZ device must be configured to use the COM5 port (see Third Party IP Device and Analog Camera Configuration). 3 1 5 6 7 8 4 9 13 14-18 2 10 11 12 19 21 22 20 Keyboard Controller (Optional) Follow the documentation that was included with your IP keyboard controller to connect it to the NVR. Network Connections Connect a network PoE switch to the camera network port at the rear of the NVR. Connect your cameras to the network PoE switch with CAT5 Ethernet cables. Optionally, connect the client workstation network port to your client workstation network through a network switch. This allows remote access to your NVR. The default client workstation network IP address must be changed to an available static IP address on your client workstation network. Monitor(s) The MAXPRO NVR HYBRID SE comes with built-in graphics and four types of monitor outputs. The unit supports connection of a single monitor using one of the outputs. The recommended resolution for your monitor is 1280 x 1024 pixels (minimum 1024 x 768) and display colors of at least 32 bit. Dual Network Configuration Contact your dealer to purchase Honeywell and third-party IP and analog cameras and encoder. Power Up the Unit Note Honeywell recommends using an uninterruptible power supply (UPS) for the NVR unit, the camera network switch, and the cameras to ensure that the NVR can continue to record video during a power outage or during transient power events. If you need to monitor video during a power outage, consider a UPS for the monitor as well. 1. Before powering up the NVR, turn on camera(s) and other devices — such as a network switch or router — connected to the NVR. It can take up to two minutes for IP cameras to boot up. Online cameras can be easily discovered by the unit after starting up. 2. Press the power button on the front of the NVR. Front Panel 3. After powering on the unit, you are prompted to log on. The Default user is user name: NVR-Admin, password: Password$123. The user name and password are case sensitive. You will be prompted to create a new password the first time that you log in. The setup wizard starts automatically but may take two minutes to initiate. Note Translated Quick Install Guides can be accessed on your MAXPRO NVR unit after logging in, by clicking on Start menu Honeywell Quick Install Guides. HDMI Output to HDMI monitor DVI-D Output to DVI monitor VGA Output to VGA monitor Display Output to DP monitor Local Monitor (not supplied) Mobile Devices MAXPRO ® NVR HYBRID SE Router/ Firewall Wireless Router Network Client Workstation Camera Network PoE Switch Client Workstation Network Switch Honeywell and Third-Party IP Cameras H4D2F1 HD4HDIH H3D2F1 HD3HDIH HCD2F HCD5HIH Camera Network Port (default 192.168.1.101) Client Workstation Network Port (default 172.25.254.101) Analog Cameras CAT5e CAT5e CAT5e CAT5e CAT5e CAT5e CAT5e USB USB VGA/DVI-D/HDMI/DP HD1 HD2 HD3 HD4 RESET OPEN OPEN HDD status LEDs Green = HDD is operating Red = Fan is off Reset unit Power button Power LED (green) On = system powered up HDD activity Fan status LED Green = Fan is operating Red = Fan is not operating HDD drive button unlocks HDD lever Open CD-ROM drive tray HDD lever opens the HDD drive tray. Push in to lock.

MAXPRO NVR HYBRID SE - Honeywell... 800-15885V4 – Rev A – 08/2016 MAXPRO® NVR HYBRID SE (Standard Edition) Hybrid Network Video Recorder Quick Install Guide Document 800

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MAXPRO NVR HYBRID SE - Honeywell... 800-15885V4 – Rev A – 08/2016 MAXPRO® NVR HYBRID SE (Standard Edition) Hybrid Network Video Recorder Quick Install Guide Document 800

www.honeywell.com/security 800-15885V4 – Rev A – 08/2016

MAXPRO® NVR HYBRID SE(Standard Edition)Hybrid Network Video Recorder

Quick Install GuideDocument 800-15885V4 – Rev A – 08/2016

Introduction

Welcome to your new Honeywell MAXPRO® NVR HYBRID SE. This guide helps you set up the NVR right out of the box. Before installing your NVR, please read this guide carefully.

Note Translated Quick Install Guides can be accessed on your MAXPRO NVR unit after logging in, by clicking on Start menu Honeywell Quick Install Guides.

Unpack

Check that the items received match those listed on the order form and packing slip. The packing box should include, in addition to your NVR unit and this guide:

Install the Hardware

Mount the MAXPRO NVR HYBRID SE Unit Mount the NVR either on a flat surface or in a rack mount ears supplied.

Connect the Hardware

Rear Panel

Not shown: Rack mount earsHDMI to DVI-D adapterMAXPRO NVR DDNS Installation InstructionsRS485 adapterI/O connectors

Recovery USB Flash Drive

MAXPRO NVR Client Software (Single Site) and Server Software DVD (includes manuals)

MAXPRO Viewer Multi-Site Viewing Software Kit (includes DVD and Getting Started Guide). Not shown.

Note Other peripheral hardware (owner supplied) will also be needed for your installation (such as cameras, network PoE switch for the camera network, network switch for a client workstation network, a monitor, and an optional keyboard controller).

To access the front LEDs and HDDs (hard drives), use the security key to unlock, then pull the front panel toward you.

DVIHDMI

Display Port

Connect supplied keyboard and mouse before powering up the NVR.

Connect up to 16 analog cameras to the Video Input connectors.

Connect a local monitor to one of the monitor outputs.

# Connector Connects to...1 Power Switch2 AC Power Electrical outlet3 Video Inputs, Outputs (BNC) Analog cameras4 Control Outputs5 Alarm Inputs6 VGA Port VGA monitor7 DVI-D Port Monitor8 Display Port Monitor9 HDMI Port HDMI monitor10 LAN1 - Camera Network Port Network11 USB Ports (x4) Various devices12 LAN2 - Client/Workstation Network Port Network13 S/PDIF (Optical) Not supported14-18 Audio Inputs and Outputs Line in - line level

Speaker outMicrophone in - not used

19 RCA Connector Sport monitor (RCA)20 Video Out Port 1–8 Analog camera looping output21 Video Out Port 9–16 Analog camera looping output22 RS485 PTZ device ** An analog PTZ device must be configured to use the COM5 port (see Third Party IP Device and Analog Camera Configuration).

3

1

5

6

7

8

4

9 13

14-18

2

10

11

12

19

21

22

20

Keyboard Controller (Optional) Follow the documentation that was included with your IP keyboard controller to connect it to the NVR.

Network Connections Connect a network PoE switch to the camera network port at the rear of the NVR. Connect your cameras to the network PoE switch with CAT5 Ethernet cables. Optionally, connect the client workstation network port to your client workstation network through a network switch. This allows remote access to your NVR. The default client workstation network IP address must be changed to an available static IP address on your client workstation network.

Monitor(s) The MAXPRO NVR HYBRID SE comes with built-in graphics and four types of monitor outputs. The unit supports connection of a single monitor using one of the outputs.

The recommended resolution for your monitor is 1280 x 1024 pixels (minimum 1024 x 768) and display colors of at least 32 bit.

Dual Network Configuration

Contact your dealer to purchase Honeywell and third-party IP and analog cameras and encoder.

Power Up the Unit

Note Honeywell recommends using an uninterruptible power supply (UPS) for the NVR unit, the camera network switch, and the cameras to ensure that the NVR can continue to record video during a power outage or during transient power events. If you need to monitor video during a power outage, consider a UPS for the monitor as well.

1. Before powering up the NVR, turn on camera(s) and other devices — such as a network switch or router — connected to the NVR. It can take up to two minutes for IP cameras to boot up. Online cameras can be easily discovered by the unit after starting up.

2. Press the power button on the front of the NVR.

Front Panel

3. After powering on the unit, you are prompted to log on. The Default user is user name: NVR-Admin, password: Password$123. The user name and password are case sensitive. You will be prompted to create a new password the first time that you log in.

The setup wizard starts automatically but may take two minutes to initiate.

Note Translated Quick Install Guides can be accessed on your MAXPRO NVR unit after logging in, by clicking on Start menu Honeywell Quick Install Guides.

HDMI Output to HDMI monitor

DVI-D Output to DVI monitor

VGA Output to VGA monitor

Display Output to DP monitor

Local Monitor (not supplied) Mobile Devices

MAXPRO® NVR HYBRID SE

Router/Firewall

Wireless Router

Network

Client Workstation

Camera Network PoE SwitchClient Workstation Network Switch

Honeywell and Third-Party IP Cameras

H4D2F1HD4HDIH H3D2F1

HD3HDIH

HCD2FHCD5HIH

Camera Network Port (default 192.168.1.101)

Client Workstation Network Port (default 172.25.254.101)

Analog Cameras

CAT5e

CAT5eCAT5e CAT5e

CAT5e

CAT5eCAT5e

USB

USBVGA/DVI-D/HDMI/DP

HD1

HD2

HD3

HD4

RESET

OPEN

OPEN

HDD status LEDsGreen = HDD is operatingRed = Fan is off

Reset unit

Power button

Power LED (green)On = system powered upHDD activity

Fan status LEDGreen = Fan is operatingRed = Fan is not operating

HDD drive button unlocks HDD lever

Open CD-ROM drive tray

HDD lever opens the HDD drive tray. Push in to lock.

Page 2: MAXPRO NVR HYBRID SE - Honeywell... 800-15885V4 – Rev A – 08/2016 MAXPRO® NVR HYBRID SE (Standard Edition) Hybrid Network Video Recorder Quick Install Guide Document 800

2 | MAXPRO® NVR HYBRID SE Quick Install Guide

© 2016 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means without written permission from Honeywell. The information in this publication is believed to be accurate in all respects. However, Honeywell cannot assume responsibility for any consequences resulting from the use thereof. The information contained herein is subject to change without notice. Revisions or new editions to this publication may be issued to incorporate such changes. For patent information, see www.honeywell.com/patents.

Document 800-15885V4 – Rev A – 08/2016

www.honeywell.com/security+1 800 323 4576 (North America only)

https//honeywellsystems.com/ss/techsupp/index.html

www.honeywell.com/security/uk+44 (0) 1928 754 028 (Europe only)

https//honeywellsystems.com/ss/techsupp/index.html

Honeywell IP Camera Configuration

Using the MAXPRO NVR Wizard (3 Clicks* to Live Video)

Note The setup wizard starts automatically but may take two minutes to initiate.

Live View

1. Please wait while the system logs you on automatically as a Windows Logged-In User.

2. MAXPRO NVR launches and the Viewer tab displays (see below).

3. To view video from cameras, drag MAXPRO NVR in the Devices list into the display panel to show video from all discovered cameras in the Viewer. You can also highlight and drag each camera into a panel.

MAXPRO® VIEWERMulti-site Viewing Software

Honeywell Confidential& ProprietaryHNMVIEWERSoftware

Copyright 2013

Honeywell Inte rnat ional Inc.

All rights reserved.

1. The CONFIGURATION dialog appears. When the network is ready (network icon in Windows tray), click to accept the default settings and proceed to CAMERA DISCOVERY.

To modify the settings for your unique system requirements, follow the table below. After initial setup, you can do this in the MAXPRO NVR client.

2. The CAMERA DISCOVERY window appears.

A pop-up message explains the available free channels in the system and how to delete unused analog channels to add IP cameras. Click OK.

Note 16 analog channels are pre-configured in the unit utilizing the 16 channel license. To add an IP camera, unused pre-configured analog channels can be deleted. See Third Party IP Device and Analog Camera Configuration.

Each newly connected camera is identified and an IP address is assigned to the camera by the Wizard, after which the camera reboots. It may take a few minutes before cameras are discovered and added. You will see a Discovery in progress… indicator as well as a pop-up message on the lower right of your monitor. Click .

3. The INSTALLATION window appears. Click to start the MAXPRO NVR application. Proceed to Live View.

4. Only Honeywell IP cameras and HVE encoders (except Honeywell Performance Series and New equIP® Series IP cameras) are discovered and added in the MAXPRO NVR Wizard.

* 3 clicks for specific models with default settings and in a local area network.

Field Description

Video Format NTSC, PAL

Enable Continuous Recording

Start recording as soon as the camera is added in MAXPRO NVR.

Dynamic IP Synchronization

NVR synchronizes any change in a device’s IP address.

Auto Add Discovered Cameras

Any newly connected device is automatically added to the Devices list.

Choose Camera Network

Choose your camera network.

Auto IP Assignment Assigns a valid static IP address to the camera. Use only if you do not have a DHCP server and you want to assign an IP address in your computer network range.

Filter Discovered Cameras

Filter the discovered cameras based on the camera model and/or IP range.

Return to CONFIGURATION page.

Click onlyafter all

connectedcameras are

discoveredand added.

Reset values without saving changes.

Proceed toCAMERA

DISCOVERY.

WATCH

User currently logged on Number of alarms detected

List of Honeywell IP devices and analog cameras connected to and discovered by MAXPRO NVR.

Devices tab: currently active. Alarms tab: acknowledge and clear alarms.

Timeline

Change playing speed

Play inreverse Pause

Play forward

Select date and timeto start recording

Time jump control to quickly locate video

Images/Clips: select images and clips to view.Double-click or drag the clip to a Viewer panel to view.To export a clip for forensics, click the arrow to switch to Full Timeline mode, then click the Clip Export icon.

Third Party IP Device and Analog Camera Configuration

Additional Configuration

MAXPRO NVR Web Client

To access the Web Client, click on the MAXPRO NVR Web Client shortcut on the NVR desktop. Click Continue on the self signed certificate warning message that appears. Login to the Web Client with default Username: admin and Password: trinity.

MAXPRO NVR HYBRID SE Default IP Address Configuration

If more than one MAXPRO NVR HYBRID SE unit is on the same network, you must assign a unique IP address and computer name to each unit (the default name is MAXPRO-NVR).

To change the IP address:

1. Click the network icon ( ) or ( ) located next to the clock (lower right of screen), click Open Network and Sharing Center, then click Change adapter settings.

2. Right click Camera Network or Client Workstation Network, and then select Properties.

3. Click Internet Protocol Version 4 (TCP/IPv4), then click Properties.

4. Click Use the following IP address, then in the IP address, Subnet mask, and Default gateway boxes, type the IP address settings.

5. Click Use the following DNS server addresses, and then, in the Preferred DNS server and Alternate DNS server boxes, type of the addresses of the primary and secondary DNS servers. This step is required when clients connect through the Internet.

To change the computer name:

1. Click Start, right-click Computer, click Properties, click Advanced system settings, click the Computer Name tab, and then click Change.

2. Under Computer name, delete the old computer name, type a new computer name, and then click OK. The name cannot contain spaces or all numbers or any of the following characters: < > ; : " * + = \ | ?.

3. After changing the computer name, restart the computer.

4. Navigate to the C:\Program Files(x86)\Honeywell\MaxproNVR\TrinityFramework\bin folder, and then double-click MaxproNVRMachineNameUtility.exe to open the MAXPRO NVR Utility.

5. The new computer name should automatically appear in the Machine Name field. If it does not, enter the name manually. Click Update. The message Machine Name Updated successfully appears when the update is complete.

More Information

1. On the Configurator tab, click the Camera tab.

2. Click (Auto Discovery) to automatically discover the connected IP cameras in the subnet.

3. Click (Manual Add) to manually add the IP device to the Camera list. Enter the device’s IP address into the field and ensure that the user name and password listed for the new camera match the user name and password of the camera.

To delete a pre-configured analog channel, select the check box next to the appropriate camera, then click Delete. A confirmation message appears (bottom of the display area). Click Yes to delete the selected camera.

4. To change the default parameters of a camera, select it and then click at the beginning of the camera line to open the camera advanced settings pane where you can modify the settings as required.

5. Click Save for your new settings to take effect.

2

1

4

53

Use the Search tab to search for recorded video (clips) or events.

Use the Configurator tab to configure video devices and set up your MAXPRO NVR system. Configurator tab sub-tabs:

System: System information, event recording, email, archival schedule, holiday/exceptions for schedules.

Disk: Configure and monitor video storage hard drives.

Camera: Discover and add network cameras, live camera configuration, recording, video motion detection.

Schedule: Set recording schedules configuration.

I/O: Configure input and output for each camera.

Sequence: Select a sequence of cameras for live video.

User: Set user access and permission levels.

Your MAXPRO NVR HYBRID SE unit has two configured network ports with the following default static IP addresses:

• 192.168.1.101 for LAN1 (Camera Network)

• 172.25.254.101 for LAN2 (Client Workstation Network)

MAXPRO NVR HYBRID SE Third Party Devices

Please refer to the appropriate user guide located on the software/documentation DVD or on the Honeywell product web site atwww.honeywell.com/security.

The MAXPRO NVR Guides (Installation and Configuration Guide, and Operator’s Guide) provide detailed information on adding and configuring third party cameras, the multi-function Web Client, as well as other advanced features.

A comprehensive list of all the third party devices supported by MAXPRO NVR HYBRID SE is available on the product compatibility page: www.security.honeywell.com/hota/compatibility/index.html.

WATCH