6

Maximum width - 5 metres - Coopers Fire...Maximum width - 5 metres per roller Maximum drop - 4 metres SS 15/28 150 280 Front Cover Galv. MS 18swg 1.2mm Thk Roller/Barrel 70x1.5mm ERW

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Maximum width - 5 metres - Coopers Fire...Maximum width - 5 metres per roller Maximum drop - 4 metres SS 15/28 150 280 Front Cover Galv. MS 18swg 1.2mm Thk Roller/Barrel 70x1.5mm ERW
Page 2: Maximum width - 5 metres - Coopers Fire...Maximum width - 5 metres per roller Maximum drop - 4 metres SS 15/28 150 280 Front Cover Galv. MS 18swg 1.2mm Thk Roller/Barrel 70x1.5mm ERW

Maximum width - 5 metres

Maximum drop - 4 metres

SS 15/15

150

15

0

Front Cover Galv. MS

18swg 1.2mm Thk

UL Approved Smoke

Brush Strip

Roller/Barrel

70x1.5mm ERW Tube

Stall Bracket Mild Steel

5mm Thick

Bottom Bar Galv. MS

14swg 2mm Thk

Bottom Cover Galv.

MS 18swg 1.2mm Thk

DRAWN:

CHECKED:

APPROVED:

TITLE:

DRG. No. ISSUE:

DATE:

Edward House, Penner Road,Havant, Hampshire, PO9 1QZ, UK

Tel: +44 (0) 23 9245 4405Fax: +44 (0) 23 9249 2732

Email: [email protected]: www.coopersfire.com

Coopers Fire Limited

© 1997 A COOPER GROUP LIMITED

ALL RIGHTS RESERVED. THIS DESIGN MAY NOT BE

REPRODUCED IN ANY MATERIAL FORM, INCLUDING

ELECTRONICALLY WITHOUT THE WRITTEN PERMISSION

OF THE COPYRIGHT NAMES

ALL DIMENSION IN MILLIMETERS

UNLESS OTHERWISE STATED

COOPERS SMOKESTOP® DRAFT CURTAIN

HEADBOX WITH S.SEAL CONFIGURATION

606/285/MK

D

14.02.2017

ML

JR

CJL

Page 3: Maximum width - 5 metres - Coopers Fire...Maximum width - 5 metres per roller Maximum drop - 4 metres SS 15/28 150 280 Front Cover Galv. MS 18swg 1.2mm Thk Roller/Barrel 70x1.5mm ERW

Maximum width - 5 metres

Maximum drop - 9 metres

SS 18/18

180

18

0

Front Cover Galv. MS

18swg 1.2mm Thk

Roller/Barrel

70x1.5mm ERW Tube

Stall Bracket Mild

Steel 5mm Thick

Bottom Bar Galv. MS

14swg 2mm Thk

Bottom Cover Galv.

MS 18swg 1.2mm Thk

UL Approved Smoke

Brush Strip

DRAWN:

CHECKED:

APPROVED:

TITLE:

DRG. No. ISSUE:

DATE:

Edward House, Penner Road,Havant, Hampshire, PO9 1QZ, UK

Tel: +44 (0) 23 9245 4405Fax: +44 (0) 23 9249 2732

Email: [email protected]: www.coopersfire.com

Coopers Fire Limited

© 1997 A COOPER GROUP LIMITED

ALL RIGHTS RESERVED. THIS DESIGN MAY NOT BE

REPRODUCED IN ANY MATERIAL FORM, INCLUDING

ELECTRONICALLY WITHOUT THE WRITTEN PERMISSION

OF THE COPYRIGHT NAMES

ALL DIMENSION IN MILLIMETERS

UNLESS OTHERWISE STATED

COOPERS SMOKESTOP® DRAFT CURTAIN

HEADBOX WITH S.SEAL CONFIGURATION

606/287/MK

D

14.02.2017

ML

JR

CJL

Page 4: Maximum width - 5 metres - Coopers Fire...Maximum width - 5 metres per roller Maximum drop - 4 metres SS 15/28 150 280 Front Cover Galv. MS 18swg 1.2mm Thk Roller/Barrel 70x1.5mm ERW

Maximum width - 5 metres per roller

Maximum drop - 4 metres

SS 15/28

150

280

Front Cover Galv. MS

18swg 1.2mm Thk

Roller/Barrel

70x1.5mm ERW Tube

Stall Bracket Mild Steel

5mm Thick

Bottom Bar Galv. MS

14swg 2mm Thk

Bottom Cover Galv.

MS 18swg 1.2mm Thk

UL Approved Smoke

Brush Strip

DRAWN:

CHECKED:

APPROVED:

TITLE:

DRG. No. ISSUE:

DATE:

Edward House, Penner Road,Havant, Hampshire, PO9 1QZ, UK

Tel: +44 (0) 23 9245 4405Fax: +44 (0) 23 9249 2732

Email: [email protected]: www.coopersfire.com

Coopers Fire Limited

© 1997 A COOPER GROUP LIMITED

ALL RIGHTS RESERVED. THIS DESIGN MAY NOT BE

REPRODUCED IN ANY MATERIAL FORM, INCLUDING

ELECTRONICALLY WITHOUT THE WRITTEN PERMISSION

OF THE COPYRIGHT NAMES

ALL DIMENSION IN MILLIMETERS

UNLESS OTHERWISE STATED

COOPERS SMOKESTOP® DRAFT CURTAIN

HEADBOX WITH S.SEAL CONFIGURATION

606/289/MK

D

14.02.2017

ML

JR

CJL

Page 5: Maximum width - 5 metres - Coopers Fire...Maximum width - 5 metres per roller Maximum drop - 4 metres SS 15/28 150 280 Front Cover Galv. MS 18swg 1.2mm Thk Roller/Barrel 70x1.5mm ERW

Maximum width - 5 metres per roller

Maximum drop - 9 metres

SS 18/36

180

36

0

Front Cover Galv. MS

18swg 1.2mm Thk

Roller/Barrel

70x1.5mm ERW Tube

Stall Bracket Mild Steel

5mm Thick

Bottom Bar Galv. MS

14swg 2mm Thk

Bottom Cover Galv.

MS 18swg 1.2mm Thk

UL Approved Smoke

Brush Strip

DRAWN:

CHECKED:

APPROVED:

TITLE:

DRG. No. ISSUE:

DATE:

Edward House, Penner Road,Havant, Hampshire, PO9 1QZ, UK

Tel: +44 (0) 23 9245 4405Fax: +44 (0) 23 9249 2732

Email: [email protected]: www.coopersfire.com

Coopers Fire Limited

© 1997 A COOPER GROUP LIMITED

ALL RIGHTS RESERVED. THIS DESIGN MAY NOT BE

REPRODUCED IN ANY MATERIAL FORM, INCLUDING

ELECTRONICALLY WITHOUT THE WRITTEN PERMISSION

OF THE COPYRIGHT NAMES

ALL DIMENSION IN MILLIMETERS

UNLESS OTHERWISE STATED

COOPERS SMOKESTOP® DRAFT CURTAIN

HEADBOX WITH S.SEAL CONFIGURATION

606/291/MK

D

14.02.2017

ML

JR

CJL

Page 6: Maximum width - 5 metres - Coopers Fire...Maximum width - 5 metres per roller Maximum drop - 4 metres SS 15/28 150 280 Front Cover Galv. MS 18swg 1.2mm Thk Roller/Barrel 70x1.5mm ERW

'W'

'D

'

'W'

'D

'

'X'

'Y

'

'X'

'Y

'

SINGLE ROLLER UNIT MULTIPLE ROLLER UNIT

W D

X (mm) Y (mm)

< 5m < 4m 150 150

< 5m < 9m 180 180

W D

X (mm) Y (mm)

Unlimited < 4m 150 280

Unlimited < 9m 180 360

NOTE: - SIZES OUTSIDE THESE STANDARDS - PLEASE CONTACT COOPERS

SEE DRG

606/328

SEE DRG

606/328

DRAWN:

CHECKED:

APPROVED:

TITLE:

DRG. No. ISSUE:

DATE:

© 1997 A COOPER GROUP LIMITED

ALL RIGHTS RESERVED. THIS DESIGN MAY NOT BE REPRODUCED IN ANY

MATERIAL FORM, INCLUDING ELECTRONICALLY WITHOUT THE WRITTEN

PERMISSION OF THE COPYRIGHT NAMES

ALL DIMENSION IN MILLIMETERS UNLESS

OTHERWISE STATED

Edward House, Penner Road,Havant, Hampshire, PO9 1QZ, UK

Tel: +44 (0) 23 9245 4405Fax: +44 (0) 23 9249 2732

Email: [email protected]: www.coopersfire.com

Coopers Fire Limited

COOPERS SMOKESTOP® DRAFT CURTAIN

MATRIX OF SIZES

600/613/MK

D

14.02.2017

ML

JR

CJL