8
Answers for industry. siemens.com/wincc-tia-portal Maximum Configuration Efficiency for All Machine-Level HMI Applications SIMATIC WinCC in the Totally Integrated Automation Portal

Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

  • Upload
    vanthu

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

Answers for industry.

siemens.com/wincc-tia-portal

Maximum Configuration Efficiency for All Machine-Level HMI ApplicationsSIMATIC WinCC in the Totally Integrated Automation Portal

Page 2: Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

With the Totally Integrated Automation Portal (TIA Portal), you can rely on a uniform environment

for programming and configuring control, visualization and drive solutions. This integrated engineering

framework sets new efficiency standards for the implementation of automation solutions – in all sectors,

worldwide.

Integrated engineering framework for all automation tasksTotally Integrated Automation Portal

Intuitive, efficient, provenWith its intuitive user interface, efficient navigation and proven technology, the TIA Portal offers innovative highlights in many regards. This multitude of advantages facilitates the minimization of engineering time, costs and expenditures – from development, to mounting and commissioning, down to maintenance and expansion of automation systems.

The design of the TIA Portal’s software editors is based on a joint layout and navigation concept. Whether hardware configuration, logics programming, frequency converter parameterization or HMI screen designing: Each environment features the same editor design – for targeted time- and cost-savings. Functions, properties

and libraries are automatically arranged in a highly intui-tive manner – matched to the action at hand.

Also switchover between the editors is ever so easy – thanks to “intelligent drag & drop,” “auto completion (IntelliSense)” and many additional features. They facili-tate the engineering of a complete automation system instead of just individual components.

Page 3: Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

HMI engineering redefinedSIMATIC WinCC (TIA Portal)

Direct access to control variables

Configuration of animated graphics

Configuration of motion paths

Definition of project languages

The TIA Portal for the first time combines the

engineering systems for various automation

tasks. A joint framework, a uniform interface

and the identical configuration of comparable

automation tasks ensure minimum familiarization

time coupled with a high recognition value.

Elaborate down to the detail – for maximum engineering efficiencyAll software editors feature a joint layout and navigation concept in order to ensure time- and cost-saving operation in the TIA Portal. Moreover, intelligent wizards support the user with routine tasks – and guarantee first-class results in minimum time. All configuration objects can be saved in a library – this applies to individual blocks as well as complete screens or variables. Faceplates can be compiled from simple image objects in a customer- or project-specific manner. Faceplate changes can be effected centrally via the block definition.

Scalability from Basic Panels to multi-user systemsWinCC (TIA Portal) offers integrated engineering for the software-based configuration of various HMI target devices – from Basic Panels to multi-user applications. Particularly with regard to engineering, WinCC (TIA Portal) offers numerous advantages. Grid-based editors, object- oriented variables view and interconnected messages and archive tags, simple system functions and comfortable script editors ensure maximum engineering efficiency for HMI applications.

Intuitive user interface with maximum convenienceEditors which are adapted to the configuration tasks and processes as well as current Windows technologies form the basis for the intuitive operating concept of WinCC (TIA Portal). The embedding of various editors in a shared working environment ensures the constant up-to-date availability of all data to the user and supports project data overview at all times.

Investment protection through migrationAs WinCC (TIA Portal) supports the migration of WinCC flexible 2008 SP2 or SP3 projects as well as of WinCC V7.0 SP3 projects, previous investments are optimally protected.

Page 4: Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

SIMATIC WinCC Runtime Increased transparency for production

Runtime operating screen of a complex application in the wood-processing industry

All HMI functions onboardIndustrial-standard HMI functions form part of the system’s basic equipment:

•Machine or system operation via an individually adjustable user interface – e.g. with buttons, switches and sliders

• Visualization of process workflows and states with dynamic graphics, bar charts and indicator instruments

• Signaling and acknowledgement of events•Archiving of measured values and messages• Logging of current process and acquired archive data•User and access right administration

Independent WinCC Runtime versions for PC platforms:

• SIMATIC WinCC Runtime Advanced covers applications with PC-based operation and monitoring solutions for single-user systems in the machine-level range

• SIMATIC WinCC Runtime Professional is the PC-based process visualization or SCADA system for the visualization and operation of processes, production workflows, machines and systems in all industries

Page 5: Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

SIMATIC Panels and PC-based HMI solutions with WinCC Runtime Advanced and WinCC Runtime Professional comprise all important functions for the operation and monitoring of machines or systems. The functionality’s application scope can be extended by means of additional options.

WinCC Server / WinCC Client • For the coordinated operation of one or

multiple operator and monitoring stations in networked automation systems

WinCC WebNavigator • For system operation and monitoring via

Internet/Intranet or LAN – without changes in the WinCC project

WinCC Recipes (previously: User Archives) • For the management (saving, loading and

restoring) of recipes (interrelated machine and production data) which are to be trans- ferred to the control in a concentrated way

WinCC Logging (previously: Archiving)• For the archiving of process values and

messages for detailed operating state analyses throughout the process

WinCC DataMonitor • For the display, analysis, evaluation and

distribution of current process states as well as historical data and messages from the process database

SIMATIC B.Data •Modular and sector-neutral energy

management and operational information system for industrial plants

WinCC Audit • Recording of operations in an audit trail,

electronic signature for important production- relevant user actions and user support for compliance with special quality requirements

WinCC Sm@rtServer • Flexible solution for location-independent

access to HMI systems as well as machines and systems, for remote machine and system maintenance via the Internet/Intranet

Multitude of optionsRuntime – tailored functionality

DataMonitor

WinCC client / WinCC server

WinCC clients (max. 32)

WinCC server

LAN

PROFINET

PROFIBUS

WinCC Sm@rtServer

Engineering station PC / programming device

Industrial Ethernet

ISDN/DSL modem / router

ISDN/DSL modem / router

Internet

TPC/IP

Page 6: Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

WinCC (TIA Portal) optimally supports communication between various HMI devices and the new SIMATIC S7-1500 controllers. Thanks to the integration of STEP 7 and WinCC in the TIA Portal, the symbolic addressing

of data on the S7-1500 can be simply used in the HMI. In addition, the new alarm and diagnostics concept of S7-1500 controllers is supported for HMI devices in WinCC (TIA Portal).

First choice for efficient engineeringOverview and highlights

SIMATIC WinCC (TIA Portal) offers an integrated engineering system with excellent usability for the current

SIMATIC panels and PC systems. Furthermore, it comprises the visualization software for PC-based runtime

stations of single- and multi-user solutions.

• Scalability from Basic Panels to multi-user systems•Optimum support of new SIMATIC S7-1500 controllers• Intuitive user interface with maximum convenience• Joint data archiving and integrated symbols • Perfect interaction of controller and HMI in a shared work environment• System diagnostics as integral element• Comprehensive library concept• Easy editing of projects with different engineering versions• Investment protection through migration

WinCC Server and WinCC Client for the assembly of a high-performance client/server system: Multiple coordinated operator and monitoring stations can be operated in joint assembly with networked automation systems.

WinCC WebNavigator for system operation and monitoring via the Internet, corporate Intranet or LAN.

WinCC WebNavigator clients

Internet

WinCC server

WinCC client WinCC client WinCC client

SIMATIC HMI operator panels

SIMATIC controller S7-1200

SIMATIC controller S7-300

SIMATIC controller S7-400

WinCC WebNavigator server

Page 7: Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

The WinCC engineering software offers innovative tools for the integrated configuration of all SIMATIC HMI operator panels. It is available in several versions that are separated by increasing levels of price and performance. All versions are based on the same engineering environment and are optimally tailored to the individual HMI device classes.

The higher software package always includes the configura-tion options for the lower package. Powerpacks are avail-able to upgrade from WinCC Comfort to higher versions, providing cost-effective solutions when increased function-ality is required.

PC-based runtime functionality for single- and multi-user solutionsThe runtime functionality depends on the equipment of the used operator panel (available memory capacity, number of function keys, etc.) and can be expanded by additional option packages.

Scalable HMISIMATIC WinCC engineering software

The following licenses are available:

•WinCC Basic, for the configuration of SIMATIC HMI Basic Panels; WinCC Basic is included with the SIMATIC STEP 7 Basic

•WinCC Comfort, for the configuration of all SIMATIC HMI Panels – especially the new SIMATIC HMI Comfort Panels, as well as the SIMATIC HMI Basic Panels and SIMATIC Mobile Panels

•WinCC Advanced, for the configuration of PC-based HMI single-user solutions

•WinCC Professional, for process visualization and SCADA applications

The following licenses are available:

•WinCC Runtime Advanced for PC-based HMI single-user solutions with 128, 512, 2K or 4K PowerTags

•WinCC Runtime Professional for multi-user SCADA applications with 128, 512, 2K, 4K, 8K as well as 64K PowerTags

SIMATIC WinCC (TIA Portal) – engineering software and target systems

WinCC Professional

WinCC Advanced

WinCC Comfort

WinCC Basic

Basic Panels

Engi

neer

ing

soft

war

eRu

ntim

e so

ftw

are

an

d ta

rget

sys

tem

s

Integrated runtime module

Integrated runtime module

WinCC Runtime Professional

WinCC Runtime Advanced

Comfort Panels Mobile Panels

PC-based single-user systems, e.g. SIMATIC IPC

PC-based multi-user systems

SCADA functionality

Page 8: Maximum Configuration Efficiency for All Machine · PDF fileMaximum Configuration Efficiency for All Machine-Level HMI Applications ... this applies to individual blocks as well as

Subject to change without prior notice Order No.: E20001-A720-P810-X-7600 DISPO 06333 WÜ/45763 MI.AS.BB.XXXX.52.3.12 WS 04131. Printed in Germany © Siemens AG 2013

The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.

All product designations may be trademarks and product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.

Siemens offers automation and drive products with industrial security functions which support safe system and machine operation. They essentially contribute to the realization of a holistic industrial security concept. Our products are continuously advanced under this aspect. We therefore recommend you to regularly inform yourself on updates of our products and to only use the respectively current versions. Relevant information is available at: http://support.automation.siemens.com. You can also subscribe to a product-specific newsletter via this link.

Moreover, safe system and machine operation necessitates the implementation of suitable protective measures (e.g. cell protection concept) and the integration of all automation and drive components in a holistic state-of-the-art industrial security concept for the entire system or machine. Also third-party products have to be taken into account in this context. Further information is available at: www.siemens.com/industrialsecurity

Siemens AG Industry Sector Industry Automation P.O. Box 48 48 90026 NUREMBERG GERMANY

Find out more:www.siemens.com/wincc-tia-portal

Follow us on: twitter.com/siemensindustry youtube.com/siemens

SIMATIC WinCC (TIA Portal) – Take a look!

Learn everything about SIMATIC WinCC (TIA Portal)