4
The World’s Best Low Pressure Sewer System Sets a New Standard in Reliability and Convenience Custom Alarm Panels for E/One Low Pressure Sewer Systems

Maximizes Custom Alarm Panels for E/One Low Pressure … · The basic E/One Sentry panel provides features ... E. Manual Run switch ... E/One Sentry Protect Plus to maximize reliability

Embed Size (px)

Citation preview

The World’s Best Low Pressure Sewer System Sets a New Standard in Reliability and Convenience

Custom Alarm Panels for E/One Low Pressure Sewer Systems

Sent

ry M

axim

izes

Rel

iabi

lity

and

Con

veni

ence

The following features are included or available with the E/One Sentry ProtectPlus to maximize reliability and convenience:

1 VisualAlarmIndicator

2 AudibleAlarm

3 AlarmSilenceSwitch

4 GFCIReceptacle(2)120-volt,15AmpGFCIreceptacles(availableoption)

5 MainServiceDisconnectBreaker(availableoption)

6 Easy-AccessTerminalStripsInterface

7 DisplayPanelOperatingIndicators

• Ready(ACPower) Indicator • PumpRunningIndicator • TroubleIndicator • HighLevelAlarm Indicator

8 LCDDisplay

• ManualRunSwitch • MenuNavigationButtons:Scroll,

Enter,Up,Down • Troubleindicationsinclude: Brown-outCondition Run-dryCondition SystemOver-pressureCondition Run-timeLimitExceeded

9 UserSelections(Forsystemsetup/service)

• DiagnosticMode • PumpPerformanceprovides accesstoperformance statisticsincluding: Real-timeVoltage Real-timeAmperage Real-timeWattage Min/Max/AverageVolts Min/Max/AverageAmps Min/Max/AverageWatts MinimumRun-time MaximumRun-time AverageRun-time LastRun-time CycleCounter HourMeter

• InitializeSystem • RunLimit • AlarmDelay • PowerDelay

EnvironmentOneCorporation2773BalltownRoadNiskayuna,NYUSA12309-1090Voice(01)518.346.6161Fax518.346.6188www.eone.com

APrecisionCastpartsCompanyLM000323Rev.E

1

2 3

4

56

10

11

12

10 GeneratorReceptacle(availableoption)

11 AutoTransferSwitch(ACMainstoPortableGenerator)(availableoption)

12 SentryAdvisorPowerSupplyandModem

7

9

8

12

A. CircuitbreakersforpumppowerandalarmcircuitsB. AudiblehighlevelalarmindicationC. VisualhighlevelalarmindicationD. HighlevelalarmsilenceswitchE. ManualRunswitchF. Redundant“Start”functionwithhighlevelalarmG. Runindicatortoshowwhenpumpisoperating

Advance W

arningO

perating Conditions M

onitor

E/ONE SENTRY ADVISORE/OneSentryAdvisormonitorspumpperformanceandrecordseverystart,runtimedurationandstopofeachgrinderpumponthesystem.Alarmconditionscanbesentautomaticallytoservicepersonnel.

Theonlinemappingfeatureshowsthelocationofeachgrinderpumpinthesystem,whetherthereareafewstationsorhundreds.

Usereportstoreviewsystemperformanceandspotdatatrendssuchasfrequentalarmsorunusuallylongruntimes.

The basic E/One Sentry panel provides features essential to any installation:

THE E/ONE REMOTE SENTRYDISPLAY MODULEprovidesvisualandaudibleindicationwhenthewaterlevelinsidethegrinderpumptankreachesapredetermined“high”levelduringnormaloperation,orintheeventofapoweroutage(withhard-wiredversionofExtremecoreandoptionalcontactsinpanel).Itisideallysuitedforinstallationswheretheoutdooralarmpanellocationisobstructedfromview,orwhereanIndoorUnit(IDU)installationisisolatedinautilityroom.

The Remote Sentry includes:

• Alowprofileattractivecase(5.4”Wx3.69”Hx1.25”D)

• Lithiumbattery

• Audiblealarm(70dB)

• Push-to-silenceaudiblealarmswitch

• Push-to-testvisualandaudiblealarm

E/ONE SENTRY PROTECT PLUSTakingittothenextlevel,theE/OneSentryProtectPlusincludesthebenefitsoftheProtectoptionaswellasadiagnosticspackagethatprovidesadvancewarningofpendingserviceneedsbymonitoringmajoroperatingconditionsandprovidingaTroubleindicationwhentheseconditionsfalloutsideofnormalranges.Dependingupontheseverityoftheabnormalcondition,thegrinderpumpstationmaycontinuetooperate.TheProtectPlusfeaturesinclude:

• Advancedwarningofpendingserviceneeds

• Datalogging

• User-selectableoptions

TheSentrylineofalarmpanelsiscustomdesignedforusewithE/Onegrinderpumpsystems.The E/One Sentry™ alarm panels provide the latest technology and the greatest flexibilityincustomizingfeaturestosatisfyindividualneeds.Thenewalarmpanelscan be configuredtoprovidefunctionsrangingfrombasicalarmindicationtoadvancedwarningofpendingservicerequirements.Inbetween,there are numerous features availableincludinganeventcounter;run-timemeter;servicedisconnectcapability;andremotealarmindication.

LiketheE/Onegrinderpumpstation,allpanelsareULlistedandmostareCSAcertifiedandmeetallapplicableNECandNFPAcodesandstandards.Furthermore,allE/OneSentryalarmpanelsarehousedinNEMA 4X lockable enclosures,suitableformountingonawallorapost.

Now Available in Two UpgradesE/ONE SENTRY PROTECTTheE/OneSentryProtectpanelprovidesimportantprotectionfromexternalconditionsthatcouldotherwiseprovedamagingtotheE/Onegrinderpumpstation.

AddingtheProtectoptiontotheE/OneSentrypanelprovidesaTroubleindicationandshutsdownthepump/coretemporarilyintheeventofanunacceptableoperatingcondition.

Thepump/corewillautomaticallyreturntoNormaloperationwhentheconditionisresolved.TheProtectfeatureprovidesmonitoringof:

•Brownoutconditionswiththeelectricalpowersupply

•Systemover-pressureconditionsuchaswithaclosedvalve

•Run-dryoperationofthepump/core

ABOVE:Pumpperformancedatacanbeaccessedfromanyweb-enableddevice.Generatereportstodeterminehowyoursystemisperformingandidentifypotentialtroublespots.

20W, 12VDCPOWER SUPPLY

SOLID STATE SIGNAL DETECTOR PCB FOR RUNTIME DRY CONTACTS

CELLULAR MODEMWITH INTEGRATEDANTENNA

CABLEASSEMBLY

EXTRATERMINALBLOCKS

A. CircuitbreakersforpumppowerandalarmcircuitsB. AudiblehighlevelalarmindicationC. VisualhighlevelalarmindicationD. HighlevelalarmsilenceswitchE. ManualRunswitchF. Redundant“Start”functionwithhighlevelalarmG. Runindicatortoshowwhenpumpisoperating

Advance W

arningO

perating Conditions M

onitor

E/ONE SENTRY ADVISORE/OneSentryAdvisormonitorspumpperformanceandrecordseverystart,runtimedurationandstopofeachgrinderpumponthesystem.Alarmconditionscanbesentautomaticallytoservicepersonnel.

Theonlinemappingfeatureshowsthelocationofeachgrinderpumpinthesystem,whetherthereareafewstationsorhundreds.

Usereportstoreviewsystemperformanceandspotdatatrendssuchasfrequentalarmsorunusuallylongruntimes.

The basic E/One Sentry panel provides features essential to any installation:

THE E/ONE REMOTE SENTRYDISPLAY MODULEprovidesvisualandaudibleindicationwhenthewaterlevelinsidethegrinderpumptankreachesapredetermined“high”levelduringnormaloperation,orintheeventofapoweroutage(withhard-wiredversionofExtremecoreandoptionalcontactsinpanel).Itisideallysuitedforinstallationswheretheoutdooralarmpanellocationisobstructedfromview,orwhereanIndoorUnit(IDU)installationisisolatedinautilityroom.

The Remote Sentry includes:

• Alowprofileattractivecase(5.4”Wx3.69”Hx1.25”D)

• Lithiumbattery

• Audiblealarm(70dB)

• Push-to-silenceaudiblealarmswitch

• Push-to-testvisualandaudiblealarm

E/ONE SENTRY PROTECT PLUSTakingittothenextlevel,theE/OneSentryProtectPlusincludesthebenefitsoftheProtectoptionaswellasadiagnosticspackagethatprovidesadvancewarningofpendingserviceneedsbymonitoringmajoroperatingconditionsandprovidingaTroubleindicationwhentheseconditionsfalloutsideofnormalranges.Dependingupontheseverityoftheabnormalcondition,thegrinderpumpstationmaycontinuetooperate.TheProtectPlusfeaturesinclude:

• Advancedwarningofpendingserviceneeds

• Datalogging

• User-selectableoptions

TheSentrylineofalarmpanelsiscustomdesignedforusewithE/Onegrinderpumpsystems.The E/One Sentry™ alarm panels provide the latest technology and the greatest flexibilityincustomizingfeaturestosatisfyindividualneeds.Thenewalarmpanelscan be configuredtoprovidefunctionsrangingfrombasicalarmindicationtoadvancedwarningofpendingservicerequirements.Inbetween,there are numerous features availableincludinganeventcounter;run-timemeter;servicedisconnectcapability;andremotealarmindication.

LiketheE/Onegrinderpumpstation,allpanelsareULlistedandmostareCSAcertifiedandmeetallapplicableNECandNFPAcodesandstandards.Furthermore,allE/OneSentryalarmpanelsarehousedinNEMA 4X lockable enclosures,suitableformountingonawallorapost.

Now Available in Two UpgradesE/ONE SENTRY PROTECTTheE/OneSentryProtectpanelprovidesimportantprotectionfromexternalconditionsthatcouldotherwiseprovedamagingtotheE/Onegrinderpumpstation.

AddingtheProtectoptiontotheE/OneSentrypanelprovidesaTroubleindicationandshutsdownthepump/coretemporarilyintheeventofanunacceptableoperatingcondition.

Thepump/corewillautomaticallyreturntoNormaloperationwhentheconditionisresolved.TheProtectfeatureprovidesmonitoringof:

•Brownoutconditionswiththeelectricalpowersupply

•Systemover-pressureconditionsuchaswithaclosedvalve

•Run-dryoperationofthepump/core

ABOVE:Pumpperformancedatacanbeaccessedfromanyweb-enableddevice.Generatereportstodeterminehowyoursystemisperformingandidentifypotentialtroublespots.

20W, 12VDCPOWER SUPPLY

SOLID STATE SIGNAL DETECTOR PCB FOR RUNTIME DRY CONTACTS

CELLULAR MODEMWITH INTEGRATEDANTENNA

CABLEASSEMBLY

EXTRATERMINALBLOCKS

The World’s Best Low Pressure Sewer System Sets a New Standard in Reliability and Convenience

Custom Alarm Panels for E/One Low Pressure Sewer Systems

Sent

ry M

axim

izes

Rel

iabi

lity

and

Con

veni

ence

The following features are included or available with the E/One Sentry ProtectPlus to maximize reliability and convenience:

1 VisualAlarmIndicator

2 AudibleAlarm

3 AlarmSilenceSwitch

4 GFCIReceptacle(2)120-volt,15AmpGFCIreceptacles(availableoption)

5 MainServiceDisconnectBreaker(availableoption)

6 Easy-AccessTerminalStripsInterface

7 DisplayPanelOperatingIndicators

• Ready(ACPower) Indicator • PumpRunningIndicator • TroubleIndicator • HighLevelAlarm Indicator

8 LCDDisplay

• ManualRunSwitch • MenuNavigationButtons:Scroll,

Enter,Up,Down • Troubleindicationsinclude: Brown-outCondition Run-dryCondition SystemOver-pressureCondition Run-timeLimitExceeded

9 UserSelections(Forsystemsetup/service)

• DiagnosticMode • PumpPerformanceprovides accesstoperformance statisticsincluding: Real-timeVoltage Real-timeAmperage Real-timeWattage Min/Max/AverageVolts Min/Max/AverageAmps Min/Max/AverageWatts MinimumRun-time MaximumRun-time AverageRun-time LastRun-time CycleCounter HourMeter

• InitializeSystem • RunLimit • AlarmDelay • PowerDelay

EnvironmentOneCorporation2773BalltownRoadNiskayuna,NYUSA12309-1090Voice(01)518.346.6161Fax518.346.6188www.eone.com

APrecisionCastpartsCompanyLM000323Rev.E

1

2 3

4

56

10

11

12

10 GeneratorReceptacle(availableoption)

11 AutoTransferSwitch(ACMainstoPortableGenerator)(availableoption)

12 SentryAdvisorPowerSupplyandModem

7

9

8

12