Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

Marine Cables 1/2013

Page 2: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

Helkama – a true specialistin marine cables ......................2Approvals..................................30,6/1kV cablesLKM-HF & LKM-HF Flex ............4LKMM-HF .................................8LKSM-HF & LKSM-HF Flex......10LKMSM-HF .............................14LKSM-EMC..............................16LKSM-VFD ..............................20LKAM-HF.................................22LKEM-HF.................................240,6/1kV FR cables

LKM-FRHF...............................26LKSM-FRHF ............................30LKAM-FRHF ............................24250V cablesLKM-HF ..................................36LKSM-HF.................................38LKAM-HF ................................40RFE-HF ....................................42RFE-HF (i) ...............................44RFA-HF....................................46RFA-HF (i) ...............................48250V FR cablesLKM-FRHF ..............................50LKSM-FRHF ...........................52LKAM-FRHF ...........................54RFE-FRHF................................56RFE-FRHF (i) ...........................58RFA-FRHF................................60RFA-FRHF (i) ...........................62Optical fibre cablesFXMSU....................................64FXMMS ...................................66Cabled optical fibrescharacteristics .........................68Technical informationGeneral information.................70Bending radius ........................71Diameter tolerance ..................71Core identification ...................71Current rating..........................72Short circuit current ................73Short time duty .......................74Voltage drop............................75

Subject to change without prior notice.See latest updates on our webpagewww.helkamabica.fi

Contents

Helkama is specializing in development and production of

marine and offshore cables. Our experience in this field goes

back more than thirty years. Our high technical quality has

been achieved by continuous development work supported

by our clients. In this catalogue we proudly present our most

comprehensive range of marine cables.

We have chosen to produce only halogen-free cables. They

remarkably improve the fire safety of the ships by not emitting

toxic burning fumes or thick smoke. In addition no corrosive

gases damaging the ship and its equipment are emitted in

case of a fire. Using the latest technology we have been able

to reduce cable weight and size to a minimum and still

maintain quality as well as enabling easy and fast installation.

The halogen free range of cables includes both flame-retardant

(IEC 60332-3) and fire resistant (IEC 60331-21) cables.

Helkama marine cables are approved by all major classification

societies.

As a specialized and independent

company, focusing on service, we have

been able to grow steadily by quickly

responding to our customers’ needs.

Our short delivery times, backed up by

extensive stocks, enable us to deliver

punctually and keep our clients satisfied.

This remains our goal for the future, too.

HELKAMA — a true specialist in marine cables

Marine cable factory inKaarina, Finland.

Page 3: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

ABS BV CCS DNV GL KRS LRS RMRS NK RINA CRS

ww

w.h

elk

am

ab

ica.fi

3TY

PE A

PP

RO

VA

LS

Marine cable factory inShanghai, China.

Type Approval Certificates for factories in Finland and China

Please check updated approval situation on www.helkamabica.fi

0,6/1kV FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN

LKM-HF � � � � � � � � � � � � � � � � �  LKM-HF FLEX � � � � � � � � � � � � � � � � �  LKSM-HF � � � � � � � � � � � � � � � � �  LKSM-HF FLEX � � � � � � � � � � � � � � � � �  LKSM-EMC � � � � � � � � � � � �  � �  LKAM-HF � � � � � � � � � � � � � � � �  LKEM-HF � � � � � � � � � � � � � � � � �  LKM-FRHF � � � � � � � � � � � � � � � � �  LKSM-FRHF � � � � � � � � � � � � � � � � �  LKAM-FRHF � � � � � � � � � � � � �  LKMM-HF � � � � � � � � � � � � � � � �    LKMSM-HF � � � � � � � � � � � � � � � �    1,8/3kV FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN

LKSM-VFD � � � � � � � � � � � � � �  250V FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN

LKM-HF � � � � � � � � � � � � �

LKSM-HF � � � � � � � � � � � � � � �    LKAM-HF � � � � � � � � � � � � �

LKM-FRHF � � � � � � � � � � � �

LKSM-FRHF � � � � � � � � � � � �

LKAM-FRHF � � � � � � � � � � � �

RFE-HF � � � � � � � � � � � � � � � � �  RFE-HF(i) � � � � � � � � � � � � � � � � �  RFA-HF � � � � � � � � � � � � � � � � �  RFA-HF(i) � � � � � � � � � � � � � � � � �  RFE-FRHF � � � � � � � � � � � � � � � � �  RFE-FRHF(i) � � � � � � � � � � � � � � � � �  RFA-FRHF � � � � � � � � � � � � � � � � �  RFA-FRHF(i) � � � � � � � � � � � � � � � � �  FO FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN

FXMMS � �  

� Type Approval only for Finland� Combinated TAC for Finland and China

� � Separate TAC for Finland and China� � Type Approval for Finland, pending for China� � Type Approval pending for Finland and China

� Combinated pending for TAC for Finland and China

Page 4: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

40

,6/1

kV

CA

BLE

S

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor 1,0-10mm2 IEC 60228, class 2- stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex)- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

LKM-HF and LKM-HF FLEXUnarmoured power and control cable 0,6/1kV

Application: For fixed installation in most areas and on open deck in ships.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

1/2

01

3

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi Page 1/4

Page 5: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

– – 1x1,0 5,0 35 18 20

25636 28396 1x1,5 5,5 40 23 25

25638 27000 1x2,5 5,5 55 30 25

25640 27002 1x4 6,5 70 40 30

25642 27004 1x6 7,0 95 52 30

25644 27006 1x10 8,0 140 72 35

25647 27009 1x16 Flex 9,0 185 94 40

25649 27011 1x25 Flex 11,5 290 123 50

25651 27013 1x35 Flex 12,5 385 153 50

25653 27015 1x50 Flex 14,5 540 196 60

25655 27017 1x70 Flex 17,0 750 240 70

25657 27019 1x95 Flex 19,5 975 284 80

25659 27021 1x120 Flex 21,5 1225 331 90

25661 27023 1x150 Flex 24,5 1545 381 100

25663 27025 1x185 Flex 27,0 1880 429 165

25665 27027 1x240 Flex 30,5 2495 507 185

26047 27029 1x300 Flex 33,0 3055 582 200

25581 – 2x1,0 7,5 65 15 30

25670 – 2x1,5 8,5 80 20 35

25686 – 2x2,5 9,5 115 26 40

25702 – 2x4 10,5 155 34 45

25701 – 2x6 12,0 240 44 50

25717 – 2x10 14,0 360 61 60

26054 – 2x16 Flex 16,5 490 80 70

26055 – 2x25 Flex 20,5 755 105 85

26056 – 2x35 Flex 23,0 1035 130 95

26057 – 2x50 Flex 27,5 1455 167 170

26058 – 2x70 Flex 31,5 1995 204 190

25582 – 3x1,0 8,0 80 13 35

25671 25672 3x1,5 9,0 100 16 40

25688 25689 3x2,5 10,0 145 21 45

25703 25704 3x4 11,5 200 28 50

25705 25706 3x6 13,0 310 36 55

25707 25708 3x10 15,0 465 50 65

26071 26072 3x16 Flex 17,5 625 66 75

26073 26074 3x25 Flex 22,0 970 86 90

26075 26076 3x35 Flex 25,0 1325 107 100

26077 26078 3x50 Flex 29,5 1880 137 180

26079 26080 3x70 Flex 34,5 2615 168 210

26081 26082 3x95 Flex 40,0 3455 199 240

26083 26085 3x120 Flex 44,5 4365 232 270

26084 26086 3x150 Flex 50,5 5485 267 305

26087 26088 3x185 Flex 57,0 6800 300 345

26089 26090 3x240 Flex 64,5 9045 355 390

50

,6/1

kV

CA

BLES

LKM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

1/2

01

3

Table continues on next page

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 2/4

Page 6: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

25583 – 4x1,0 8,5 95 13 35

25673 25674 4x1,5 10,0 135 16 40

25690 25691 4x2,5 11,0 180 21 45

25725 25726 4x4 12,5 260 28 55

25727 25728 4x6 14,0 385 36 60

25729 25730 4x10 16,5 585 50 70

26101 26102 4x16 Flex 19,5 800 66 80

26103 26104 4x25 Flex 24,5 1250 86 100

26105 26106 4x35 Flex 27,5 1695 107 170

26107 26108 4x50 Flex 33,0 2420 137 200

26109 26110 4x70 Flex 38,0 3350 168 230

26111 26112 4x95 Flex 44,5 4465 199 270

26113 26114 4x120 Flex 49,5 5590 232 300

25584 – 5x1,0 9,5 125 10 40

25676 25677 5x1,5 11,0 160 13 45

25692 25693 5x2,5 12,0 220 17 50

25864 25865 5x4 13,5 320 23 55

25866 25867 5x6 15,5 475 30 65

25868 25869 5x10 18,5 720 42 75

26131 26132 5x16 Flex 21,5 970 55 90

26133 26134 5x25 Flex 27,5 1545 71 165

26135 26136 5x35 Flex 30,5 2100 89 185

26137 26138 5x50 Flex 37,0 2980 114 225

26139 26140 5x70 Flex 42,5 4175 139 260

25585 – 7x1,0 10,5 155 9 45

25586 – 10x1,0 13,5 225 8 55

25587 – 12x1,0 13,5 250 8 55

25588 – 14x1,0 14,5 280 7 60

25589 – 16x1,0 15,5 325 7 65

25590 – 19x1,0 16,0 365 7 65

25592 – 24x1,0 19,0 465 6 80

25593 – 27x1,0 19,5 510 6 80

25597 – 30x1,0 20,0 555 5 85

25595 – 37x1,0 22,0 680 5 90

60

,6/1

kV

CA

BLE

S1

/20

13

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

LKM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Table continues on next page

Page 3/4

Page 7: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

25678 25679 7x1,5 11,5 200 12 50

25667 25668 10x1,5 15,0 290 11 60

25680 25681 12x1,5 15,5 335 10 65

25991 25992 14x1,5 16,5 380 10 70

25989 25990 16x1,5 17,0 430 9 70

25682 25683 19x1,5 18,5 495 9 75

25875 25876 24x1,5 22,0 635 8 90

25684 25685 27x1,5 22,0 700 8 90

25675 25687 37x1,5 25,0 920 7 100

25694 25695 7x2,5 13,5 285 16 55

25993 25994 10x2,5 17,0 410 14 70

25696 25874 12x2,5 17,5 465 13 70

25995 25996 14x2,5 18,5 535 13 75

25997 25998 16x2,5 19,5 605 12 80

25873 25872 19x2,5 20,5 690 11 85

25877 25878 24x2,5 24,5 900 10 100

26141 26142 27x2,5 25,0 990 10 155

70

,6/1

kV

CA

BLES

1/2

01

3

LKM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 4/4

Page 8: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

80

,6/1

kV

CA

BLE

S1

/20

13

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor 1,5–10mm2 IEC 60228, class 2- stranded copper conductor 16–150mm2 IEC 60228, class 5- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- extruded filler

4. Sheath- black polyolefine plastic, SHF1 IEC 60092-359- standard colour black

LKMM-HF Unarmoured power cablewith extruded filler0,6/1kV

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 9: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

90

,6/1

kV

CA

BLES

1/2

01

3

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

LKMM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

27532 – 2x1,5 9,0 110 20 3527534 – 2x2,5 10,0 155 26 4027536 – 2x4 11,0 205 34 4527538 – 2x6 12,5 285 44 5027540 – 2x10 14,5 420 61 6027543 – 2x16 18,5 630 80 7527545 – 2x25 23,0 970 105 9027547 – 2x35 25,5 1340 130 15527549 – 2x50 30,0 1855 167 18027551 – 2x70 34,0 2510 204 20527564 27566 3x1,5 9,5 130 16 3527568 27570 3x2,5 10,5 180 21 4527572 27574 3x4 12,0 245 28 4527576 27578 3x6 13,5 350 36 5527580 27582 3x10 15,5 515 50 6027585 27587 3x16 20,0 770 66 8027589 27591 3x25 24,5 1170 86 10027593 27595 3x35 27,0 1600 107 16027597 27599 3x50 32,0 2220 137 19027601 27603 3x70 37,0 3090 168 22027605 27607 3x95 42,5 4055 199 25527609 27611 3x120 47,0 5070 232 28527613 27615 3x150 53,5 6425 267 32027628 27630 4x1,5 10,5 165 16 4027632 27634 4x2,5 11,5 215 21 4527636 27638 4x4 13,0 305 28 5027640 27642 4x6 14,5 420 36 6027644 27646 4x10 17,5 635 50 7027649 27651 4x16 21,5 935 66 8527653 27655 4x25 27,0 1440 86 16027657 27659 4x35 30,0 1955 107 18027661 27663 4x50 35,5 2735 137 21027665 27667 4x70 40,5 3790 168 24527692 27694 5x1,5 11,5 195 13 4527696 27698 5x2,5 12,5 255 17 5027700 27702 5x4 14,5 360 23 5527704 27706 5x6 16,5 515 30 6027708 27710 5x10 19,0 770 42 7527713 27715 5x16 24,0 1145 55 9527717 27719 5x25 29,5 1750 71 175

5/2

00

9

Page 10: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor 1,0-10mm2   IEC 60228, class 2- stranded copper conductor 16-300mm2  IEC 60228, class 5 (Flex)- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- filler tape

4. Armour- copper wire braid, coverage > 90% IEC 60092-350- tinned copper wire braid on request

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

100

,6/1

kV

CA

BLE

S1

/20

13

LKSM-HF and LKSM-HF FLEXArmoured power and control cable 0,6/1kV

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Application: For fixed installation in most areas and on open deck in ships.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Page 1/4

Page 11: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

LKSM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

armourmm2

25955 – 1x1,0 3,0 6,0 70 18 40

25736 – 1x1,5 3,0 6,5 75 23 40

25738 – 1x2,5 3,1 7,0 90 30 45

25740 27052 1x4 3,1 7,5 105 40 45

25742 27054 1x6 3,1 8,0 130 52 50

25744 27056 1x10 3,5 9,5 190 72 60

26237 27059 1x16 Flex 4,1 10,5 240 94 65

26238 27061 1x25 Flex 4,9 13,0 360 123 80

26239 27063 1x35 Flex 5,5 14,0 460 153 90

26240 27065 1x50 Flex 8,7 17,0 650 196 105

26241 27067 1x70 Flex 11,4 19,0 885 240 115

26242 27069 1x95 Flex 11,5 21,5 1115 284 130

26243 27071 1x120 Flex 14,5 23,5 1405 331 145

26244 27073 1x150 Flex 14,7 26,5 1720 381 160

26245 27075 1x185 Flex 15,2 29,0 2065 429 180

26246 27077 1x240 Flex 18,2 32,5 2715 507 200

26247 27079 1x300 Flex 18,7 35,5 3300 582 215

25956 – 2x1,0 3,6 9,0 110 15 55

25770 – 2x1,5 3,8 9,5 130 20 60

25785 – 2x2,5 4,3 10,5 160 26 65

25801 – 2x4 4,9 12,0 210 34 75

25803 – 2x6 5,4 13,0 315 44 80

25805 – 2x10 8,7 15,5 480 61 95

26254 – 2x16 Flex 10,0 18,0 625 80 110

26255 – 2x25 Flex 14,5 23,0 985 105 140

26256 – 2x35 Flex 14,7 25,5 1240 130 155

26257 – 2x50 Flex 18,1 29,5 1700 167 180

26258 – 2x70 Flex 18,7 34,0 2270 204 205

26259 – 2x95 Flex 22,2 39,0 2965 241 235

25957 – 3x1,0 3,7 9,5 130 13 60

25772 25773 3x1,5 4,1 10,0 155 16 65

25786 25787 3x2,5 4,6 11,0 195 21 70

25802 25880 3x4 5,2 12,5 260 28 80

25804 25882 3x6 5,8 14,0 370 36 85

25806 25884 3x10 9,3 16,5 570 50 100

26271 26272 3x16 Flex 10,7 19,0 750 66 115

26273 26274 3x25 Flex 14,6 24,5 1165 86 150

26275 26276 3x35 Flex 15,0 27,0 1505 107 165

26277 26278 3x50 Flex 18,3 32,0 2100 137 195

26279 26280 3x70 Flex 22,0 36,5 2850 168 220

26281 26282 3x95 Flex 22,8 42,0 3685 199 255

26283 26284 3x120 Flex 37,8 47,0 4745 232 285

26285 26286 3x150 Flex 39,3 53,0 5885 267 320

26287 26288 3x185 Flex 47,9 59,5 7265 300 360

110

,6/1

kV

CA

BLES

1/2

01

3

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Table continues on next page

Page 2/4

Page 12: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

25958 – 4x1,0 4,1 10,0 150 13 65

25774 25775 4x1,5 4,5 11,0 180 16 70

25788 25789 4x2,5 5,0 12,5 240 21 75

25830 25831 4x4 5,8 13,5 320 28 85

25832 25833 4x6 8,8 15,5 475 36 95

25834 25835 4x10 10,3 18,0 695 50 110

26301 26302 4x16 Flex 11,9 21,0 945 66 130

26303 26304 4x25 Flex 14,8 27,0 1440 86 165

26305 26306 4x35 Flex 18,1 29,5 1900 107 180

26307 26308 4x50 Flex 19,5 35,5 2635 137 215

26309 26310 4x70 Flex 22,6 40,0 3590 168 245

26311 26312 4x95 Flex 37,8 47,0 4850 199 285

26313 26314 4x120 Flex 39,3 52,0 6010 232 315

– – 4x150 Flex 48,2 59,0 7565 267 355

25959 – 5x1,0 4,5 10,5 175 10 65

25776 25777 5x1,5 5,0 12,0 220 13 75

25790 25791 5x2,5 5,6 13,5 285 17 80

26011 26012 5x4 8,6 15,0 410 23 95

26013 26014 5x6 9,7 17,0 565 30 105

26015 26016 5x10 11,5 20,0 830 42 120

26331 26332 5x16 Flex 13,2 23,0 1070 55 140

26333 26334 5x25 Flex 18,1 29,5 1655 71 180

25960 – 7x1,0 4,9 11,5 215 9 75

25961 – 10x1,0 8,7 15,0 320 8 90

25962 – 12x1,0 9,0 15,0 350 8 95

25963 – 14x1,0 9,4 16,0 385 7 100

25964 – 16x1,0 11,4 17,0 445 7 105

25965 – 19x1,0 11,4 17,5 490 7 110

25977 – 24x1,0 12,5 20,5 610 6 125

25978 – 27x1,0 12,8 21,0 655 6 130

25981 – 37x1,0 14,4 23,5 840 5 145

120

,6/1

kV

CA

BLE

S1

/20

13

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

LKSM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

armourmm2

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16

Table continues on next page

Page 3/4

Page 13: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

25778 25779 7x1,5 5,4 13,0 265 12 80

26025 26026 10x1,5 9,6 16,5 390 11 100

25780 25846 12x1,5 9,9 17,0 440 10 105

26027 26028 14x1,5 10,5 18,0 490 10 110

26030 26029 16x1,5 11,5 19,0 545 9 115

25782 25781 19x1,5 11,7 19,5 610 9 120

25828 25829 24x1,5 13,9 23,5 780 8 140

25783 25847 27x1,5 14,1 24,0 845 8 145

25784 25848 37x1,5 16,0 26,5 1085 7 160

25792 25793 7x2,5 8,5 15,0 380 16 90

26033 26034 10x2,5 11,5 18,5 535 14 115

25794 25795 12x2,5 11,5 19,0 595 13 115

26035 26036 14x2,5 11,8 20,5 680 13 125

26037 26038 16x2,5 12,5 21,5 760 12 130

25796 25797 19x2,5 13,2 22,5 855 11 135

25798 25799 24x2,5 15,7 26,0 1080 10 160

25768 25769 27x2,5 16,1 27,0 1175 10 165

130

,6/1

kV

CA

BLES

1/2

01

3

LKSM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

armourmm2

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16

Page 4/4

Page 14: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor 1,5–10mm2 IEC 60228, class 2- stranded copper conductor 16–150mm2 IEC 60228, class 5- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- extruded filler

4. Armour- copper wire braid, coverage > 90% IEC 60092-350- tinned copper wire braid and galvanized steel wire braid on request

5. Sheath-black polyolefine plastic, SHF1 IEC 60092-359- standard colour black

Application: For fixed installation in most areas and on open deck in ships.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

140

,6/1

kV

CA

BLE

S1

/20

13

LKMSM-HF Armoured power cablewith extruded filler 0,6/1kV

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Page 15: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

27232 – 2x1,5 4,9 11,5 195 20 7027234 – 2x2,5 5,4 12,5 230 26 7527236 – 2x4 6,0 14,0 290 34 8527238 – 2x6 9,1 15,5 425 44 9027240 – 2x10 10,7 17,5 580 61 10527243 – 2x16 12,4 20,0 740 80 12027245 – 2x25 15,4 24,5 1085 105 14527247 – 2x35 17,1 27,0 1400 130 16027249 – 2x50 20,2 31,0 1895 167 19027264 27266 3x1,5 5,1 12,0 220 16 7527268 27270 3x2,5 5,7 13,5 275 21 8027272 27274 3x4 6,4 14,5 345 28 8527276 27278 3x6 9,7 16,0 495 36 9527280 27282 3x10 11,4 18,5 685 50 11027285 27287 3x16 13,2 21,0 885 66 12527289 27291 3x25 16,4 26,0 1320 86 15527293 27295 3x35 18,2 28,5 1710 107 17027297 27299 3x50 21,9 33,5 2345 137 20027301 27303 3x70 25,4 38,5 3200 168 23027305 27307 3x95 40,6 45,0 4270 199 27027309 27311 3x120 44,8 49,0 5235 232 29527313 27315 3x150 51,7 55,5 6610 267 33527328 27330 4x1,5 5,6 13,0 260 16 8027332 27334 4x2,5 6,3 14,0 320 21 8527336 27338 4x4 9,5 16,0 430 28 9527340 27342 4x6 10,6 17,5 590 36 10527344 27346 4x10 12,5 20,0 830 50 12027349 27351 4x16 14,5 23,0 1085 66 14027353 27355 4x25 18,2 28,5 1605 86 17027357 27359 4x35 20,2 31,5 2105 107 19027361 27363 4x50 24,1 37,0 2875 137 22027365 27367 4x70 45,7 43,0 4120 168 26027369 27371 4x95 45,0 49,0 5245 199 29527373 27375 4x120 51,2 55,0 6575 232 33027392 27394 5x1,5 6,1 14,0 300 13 8527396 27398 5x2,5 9,2 15,5 395 17 9527400 27402 5x4 10,4 17,0 510 23 10527404 27406 5x6 11,8 19,0 690 30 11527408 27410 5x10 13,8 22,0 985 42 13027413 27415 5x16 16,0 25,5 1300 55 15227417 27419 5x25 20,1 31,0 1925 71 185

150

,6/1

kV

CA

BLES

1/2

01

3

LKMSM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

armourmm2

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 16: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor-stranded copper conductor 1,0-10mm

2IEC 60228, class 2

-stranded copper conductor 16-150mm2

IEC 60228, class 5- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- filler tape

4. Screen- copper tape, coverage 100%

5. Armour- copper wire braid, coverage > 90% IEC 60092-350- tinned copper wire braid on request

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

160

,6/1

kV

CA

BLE

S1

/20

13

LKSM-EMC

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Application: For fixed installation in most areas and on open deck in ships.Design to meet requirements for improved EMC screening properties.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/mat 100MHz [20mΩ/m])

For details see general information section

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: See technical information section.

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Armoured power and control cablewith improved EMC screening0,6/1kV

Page 17: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

170

,6/1

kV

CA

BLES

1/2

01

3

LKSM-EMC 0,6/1kV Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approx-imateweightkg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

Cross-section of

armourmm2

26904 1x1,0 3,0 6,0 90 18 37

27513 1x1,5 3,0 6,5 100 23 39

27514 1x2,5 3,0 7,0 110 30 41

27515 1x4 3,1 7,5 130 40 45

27516 1x6 3,1 8,0 155 52 48

27157 1x10 3,3 9,5 230 72 57

27518 1x16 4,2 11,0 280 94 66

27519 1x25 4,9 13,5 405 123 80

27520 1x35 5,6 14,5 515 153 86

27521 1x50 8,8 17,0 705 196 102

27522 1x70 10,0 19,0 940 240 114

27523 1x95 11,5 21,5 1185 284 129

27524 1x120 12,4 24,0 1465 331 143

27525 1x150 14,7 26,5 1815 381 160

27526 1x185 15,3 29,5 2165 429 176

27527 1x240 17,1 33,0 2795 507 197

27528 1x300 18,8 35,5 3425 582 213

26905 2x1,0 3,3 9,5 130 15 56

27480 2x1,5 3,6 10,0 145 20 59

27481 2x2,5 4,1 11,0 180 26 65

27482 2x4 4,6 12,0 250 34 72

27483 2x6 5,1 13,0 340 44 79

27484 2x10 8,5 16,0 535 61 95

27485 2x16 11,4 18,5 725 80 112

27486 2x25 12,4 23,0 1045 105 138

27487 2x35 14,7 25,5 1325 130 153

27529 2x50 16,4 30,0 1785 167 179

27530 2x70 18,8 34,0 2385 204 204

27531 2x95 21,3 39,0 3100 241 235

Part numberNormal G-type

Table continues on next pagePage 2/4

Page 18: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

26906 26988 3x1,0 3,6 10,0 155 13 59

26861 26862 3x1,5 3,9 10,5 175 16 62

26863 26864 3x2,5 4,3 11,5 215 21 68

26865 26866 3x4 5,0 12,5 285 28 76

26867 26868 3x6 5,6 14,0 395 36 84

26869 26870 3x10 8,9 16,5 630 50 100

26872 26851 3x16 10,9 19,5 835 66 118

26874 26852 3x25 14,6 24,5 1245 86 147

26876 26853 3x35 15,2 27,0 1590 107 162

26878 26854 3x50 18,3 32,0 2205 137 193

26880 26855 3x70 22,0 36,5 2970 168 219

26882 26856 3x95 22,9 42,0 3825 199 252

26884 26857 3x120 37,9 47,0 4895 232 283

26886 26858 3x150 39,4 53,0 6060 267 319

26907 26989 4x1,0 3,9 10,5 175 13 63

26942 26943 4x1,5 4,3 11,0 200 16 67

26944 26945 4x2,5 4,9 12,5 260 21 74

26946 26947 4x4 5,5 13,5 340 28 82

26948 26949 4x6 8,5 15,5 505 36 94

26950 26951 4x10 9,9 18,5 750 50 110

26952 26953 4x16 12,0 22,0 1020 66 131

26954 26955 4x25 14,8 27,0 1510 86 161

26956 26957 4x35 18,2 30,0 1970 107 179

26958 26959 4x50 19,6 35,5 2715 137 213

26960 26961 4x70 22,6 40,0 3675 168 241

26962 26963 4x95 37,9 47,5 4935 199 284

26964 26965 4x120 39,4 52,5 6095 232 314

26966 26967 4x150 43,7 59,0 7610 267 355

26908 26990 5x1,0 4,2 11,0 200 10 67

27488 27838 5x1,5 4,7 12,0 240 13 73

27489 27839 5x2,5 5,3 13,5 305 17 80

27490 27840 5x4 11,3 15,5 460 23 92

27491 27841 5x6 11,4 17,0 615 30 102

27492 27842 5x10 11,0 20,0 875 42 120

27493 27843 5x16 13,3 23,5 1220 55 142

27494 27844 5x25 16,4 29,5 1775 71 177

180

,6/1

kV

CA

BLE

S1

/20

13

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

LKSM-EMC 0,6/1kV Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approx-imateweightkg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

Cross-section of

armourmm2

Part numberNormal G-type

Table continues on next pagePage 3/4

Page 19: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

190

,6/1

kV

CA

BLES

1/2

01

3

LKSM-EMC 0,6/1kV Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approx-imateweightkg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

Cross-section of

armourmm2

26909 26991 7x1,0 4,7 12,5 240 9 74

26910 26992 10x1,0 9,9 15,5 365 8 93

26911 26993 12x1,0 9,9 16,0 395 8 96

26912 26994 14x1,0 9,9 16,5 430 7 100

26913 26995 16x1,0 10,0 17,5 465 7 105

26914 26996 19x1,0 10,2 18,5 550 7 111

26915 26997 24x1,0 12,2 21,5 695 6 130

26916 26998 27x1,0 12,5 22,0 750 6 132

26917 26999 37x1,0 14,1 24,5 935 5 147

27495 27840 7x1,5 5,2 13,0 285 23 78

27497 27842 10x1,5 9,9 16,5 425 20 99

27499 27844 12x1,5 10,0 17,0 465 16 102

27501 27846 14x1,5 10,2 18,0 520 16 108

27503 27848 16x1,5 10,8 19,0 570 13 113

27505 27850 19x1,5 11,4 20,0 675 23 119

27507 27852 24x1,5 13,6 23,0 855 20 139

27509 27854 27x1,5 13,9 24,0 930 16 143

27511 27856 37x1,5 15,7 26,5 1175 23 160

27496 27841 7x2,5 5,8 14,5 365 30 87

27498 27843 10x2,5 11,4 18,5 555 26 111

27500 27845 12x2,5 11,5 19,0 620 21 115

27502 27847 14x2,5 11,5 20,0 690 21 120

27504 27849 16x2,5 12,2 21,5 775 17 128

27506 27851 19x2,5 12,9 22,5 910 30 135

27508 27853 24x2,5 15,3 26,0 1145 26 157

27510 27855 27x2,5 15,8 27,0 1250 21 161

Part numberNormal G-type

Page 4/4

Page 20: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 5- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- filler tape

4. Screen- copper tape, coverage 100%

5. Armour- copper wire braid, coverage > 90% IEC 60092-350- tinned copper wire braid on request

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

201

,8/3

kV

CA

BLE

S1

/20

13

LKSM-VFD

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Application: For fixed installation in most areas and on open deck in ships.Design to meet requirements for Variable Frequency Drivers (VFD).Suitable for voltage peaks up to 3kV.

Main characteristics

Rated voltage 1,8/3kV (3,6kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/mat 100MHz [20mΩ/m])

For details see general information section

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: See technical information section.Cable with yellow/green protective earth (PE)conductor on request

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Armoured power and control cablewith improved EMC screening1,8/3kV

Page 21: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

211

,8/3

kV

CA

BLES

1/2

01

3

LKSM-VFD 1,8/3kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approx-imateweightkg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

26920 1x16 5,5 14,0 355 94 85 1)26922 1x25 8,5 16,0 495 123 95 1)26924 1x35 9,3 17,0 625 153 105 1)26926 1x50 10,3 19,0 795 196 115 1)26928 1x70 11,3 20,5 995 240 125 1)26930 1x95 12,5 23,5 1280 284 140 1)26932 1x120 13,6 25,5 1525 331 150 1)26934 1x150 14,7 27,5 1830 381 165 1)26936 1x185 15,8 29,5 2165 429 180 1)26938 1x240 17,6 33,0 2800 507 200 1)26940 1x300 18,9 35,0 3365 582 210 1)26871 3x16 16,4 26,5 1165 66 16026873 3x25 16,9 29,5 1525 86 18026875 3x35 18,7 32,5 1910 107 19526877 3x50 28,8 37,0 2580 137 22526879 3x70 35,0 41,0 3395 168 24526881 3x95 35,4 46,5 4295 199 280 1)26883 3x120 38,6 50,5 5200 232 305 1)26885 3x150 42,0 55,0 6255 267 330 1)26887 3x185 45,5 60,0 7475 300 360 1)26893 3x95+3x16 35,4 46,5 4655 199 280 2)26895 3x120+3x25 38,6 50,5 5755 232 305 2)26897 3x150+3x25 42,0 55,0 6825 267 330 2)

Cross-section of

armourmm2

Note

NOTE!

1) = Protective earth (PE) rules are not fulfilled.

(PE rules, for cables over 16mm2 the PE-conductor have to be half of main conductor

and min. 16mm2. This according to IEC 60092-352, Electrical installations

in ships –Choice and installation of electrical cables)

2 = Three additional protective earth (PE) conductors.

Protective earth (PE) rules are fulfilled.

Page 22: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

220

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LKAM-HF Screened power and control cable0,6/1kV

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Screen- drain wire of tinned copper 1,0mm2 (in all sizes)

- aluminium polyester tape, IEC 60092-350 coverage 100%

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

Application: For fixed installation in most areas and on open deck in ships, especially when lightweight cables are needed.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 23: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

230

,6/1

kV

CA

BLES

1/2

01

3

LKAM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

27102 – 2x1,5 9,0 100 20 5527106 27107 3x1,5 9,5 125 16 5527110 27111 4x1,5 10,0 150 16 6027114 27115 5x1,5 11,0 175 13 6527118 27119 7x1,5 12,0 220 12 7027140 27141 10x1,5 15,5 310 11 9027122 27123 12x1,5 16,0 350 10 9527144 27145 14x1,5 16,5 395 10 10027148 27149 16x1,5 17,5 450 9 10527126 27127 19x1,5 18,5 510 9 11027130 27131 24x1,5 22,0 650 8 13027134 27135 27x1,5 22,5 710 8 13527155 27156 32x1,5 23,5 825 7 14027136 27137 37x1,5 25,0 935 7 150

27104 – 2x2,5 9,5 130 26 6027108 27109 3x2,5 10,5 160 21 6027112 27113 4x2,5 11,0 195 21 6527116 27117 5x2,5 12,5 240 17 7527120 27121 7x2,5 13,5 300 16 8027142 27143 10x2,5 17,5 430 14 10527124 27125 12x2,5 18,0 495 13 10527146 27147 14x2,5 18,5 565 13 11027150 27151 16x2,5 19,5 635 12 12027128 27129 19x2,5 21,0 740 11 12527132 27133 24x2,5 25,0 930 10 15027138 27139 27x2,5 25,5 1025 10 15027157 27158 32x2,5 26,5 1195 9 16027152 27153 37x2,5 28,5 1355 9 170

Normal G-type

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 24: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

240

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded flexible IEC 60228, copper conductor class 5

2. Insulation- HF90 plastic IEC 60092-351- standard colour black, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LKEM-HF Switchboard wire0,6/1kV

Application: For fixed wiring in switchboards, control panels and other enclosures.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Cable type, cable size, voltage and manufacturer's name

Page 25: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

250

,6/1

kV

CA

BLES

1/2

01

3

LKEM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

25117* 1x0,5 2,3 10 11 1025120 1x0,75 2,7 14 14 1525121 1x1,0 2,8 17 17 1525122 1x1,5 3,1 21 22 1525124 1x2,5 3,6 32 30 1525125 1x4 4,1 45 39 2025126 1x6 4,7 63 50 2025128 1x10 5,7 103 71 2525130 1x16 6,7 154 94 3025132 1x25 8,6 244 123 3525134 1x35 9,7 334 153 4025136 1x50 11,9 476 196 5025138 1x70 13,7 671 240 5525165 1x95 16,2 887 284 6525166 1x120 18,2 1125 331 7525279 1x150 20,8 1424 381 8525281 1x185 23,3 1753 429 9525283 1x240 26,8 2357 507 11025285 1x300 28,9 2900 582 120

* Rated voltage 300/500V

Available in colours:

blue, dark blue, black, brown, red, yellow, green, yellow/green, grey, orange, violet and white

Other colours on request Delivery lengths:

0,5 mm2, 0,75 mm2, 1 mm2, 1,5 mm2 and 2,5 mm2 available in 200 m boxes or 500 m drums

4 mm2 available in 100 m boxes or 500 m drums

6 mm2 and 10 mm2 available in 100 m coils or 500 m drums

No MOQ for other sizes

Page 26: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

260

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2 (class 5 on request)- tinned stranded copper conductor on request

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

LKM-FRHF

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Fire-resistant unarmoured powerand control cable 0,6/1kV

Page 27: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

270

,6/1

kV

CA

BLES

1/2

01

3

LKM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

28275 – 1x1,0 5,5 40 18 30

28100 – 1x1,5 5,5 45 23 35

28102 – 1x2,5 6,0 60 30 35

28104 – 1x4 6,5 80 40 40

28106 – 1x6 7,5 100 52 45

28108 – 1x10 8,5 150 72 50

28110 – 1x16 9,5 210 96 55

28112 – 1x25 11,5 320 127 70

28114 – 1x35 13,0 420 157 75

28116 – 1x50 14,5 555 196 85

28118 – 1x70 17,0 780 242 100

28120 – 1x95 19,0 1025 293 115

28122 – 1x120 21,0 1295 339 125

28124 – 1x150 23,5 1605 389 140

28126 – 1x185 26,0 1990 444 155

28128 – 1x240 29,0 2625 522 175

28130 – 1x300 32,0 3230 601 190

28276 – 2x1,0 8,5 75 15 50

28132 – 2x1,5 9,0 90 20 55

28134 – 2x2,5 10,5 125 26 65

28136 – 2x4 11,5 165 34 70

28138 – 2x6 13,0 260 44 75

28140 – 2x10 15,0 385 61 90

28142 – 2x16 17,5 550 82 105

28144 – 2x25 21,5 825 108 130

28146 – 2x35 24,0 1115 133 145

28148 – 2x50 27,0 1465 167 165

28150 – 2x70 31,5 2045 206 190

28154 – 2x95 36,0 2720 249 215

28278 28279 3x1,0 9,0 95 13 55

28162 28163 3x1,5 9,5 115 16 60

28164 28165 3x2,5 11,0 160 21 65

28166 28167 3x4 12,5 220 28 75

28168 28169 3x6 14,0 330 36 85

28170 28171 3x10 16,0 485 50 95

28172 28173 3x16 18,5 705 67 110

28174 28175 3x25 23,0 1060 89 135

28176 28177 3x35 25,5 1425 110 155

28178 28179 3x50 29,5 1905 137 175

28180 28181 3x70 34,5 2685 169 205

28202 28208 3x95 38,5 3540 205 230

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Table continues on next pagePage 2/4

Page 28: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

280

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

LKM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

28280 28281 4x1,0 9,5 115 13 60

28182 28183 4x1,5 11,0 150 16 65

28184 28185 4x2,5 12,0 200 21 75

28186 28187 4x4 13,5 280 28 80

28188 28189 4x6 15,0 405 36 90

28190 28191 4x10 18,0 610 50 105

28192 28193 4x16 20,5 900 67 125

28194 28195 4x25 25,5 1365 89 155

28196 28197 4x35 28,5 1820 110 170

28198 28199 4x50 32,5 2450 137 195

28200 28201 4x70 38,0 3430 169 230

28209 28210 4x95 43,5 4570 205 260

28282 28283 5x1,0 11,0 150 10 65

28212 28213 5x1,5 12,0 185 13 70

28214 28215 5x2,5 13,0 240 17 80

28501 28502 5x4 15,0 345 23 90

28503 28504 5x6 16,5 505 30 100

28505 28506 5x10 19,5 750 42 115

28507 28508 5x16 22,5 1100 56 135

28509 28510 5x25 28,0 1680 74 170

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Table continues on next pagePage 3/4

Page 29: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

290

,6/1

kV

CA

BLES

1/2

01

3

LKM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

28284 28285 7x1,0 12,0 180 9 70

28286 28287 10x1,0 15,0 260 8 90

28288 28289 12x1,0 15,5 295 8 95

28290 28291 14x1,0 16,5 330 7 100

28292 28293 16x1,0 17,5 380 7 105

28294 28295 19x1,0 18,5 435 7 110

28296 28297 24x1,0 21,5 550 6 130

28298 28299 27x1,0 22,0 600 6 130

28300 28301 37x1,0 25,0 805 5 150

28216 28217 7x1,5 13,0 230 12 80

28240 28241 10x1,5 16,5 330 11 100

28220 28221 12x1,5 17,5 380 10 105

28244 28245 14x1,5 18,5 430 10 110

28248 28249 16x1,5 19,5 485 9 115

28224 28225 19x1,5 20,5 565 9 125

28228 28229 24x1,5 24,5 725 8 145

28232 28233 27x1,5 25,0 795 8 150

28234 28235 37x1,5 28,0 1050 7 170

28218 28219 7x2,5 14,5 315 16 90

28242 28243 10x2,5 18,5 450 14 110

28222 28223 12x2,5 19,5 510 13 115

28246 28247 14x2,5 20,5 590 13 125

28250 28251 16x2,5 21,5 670 12 130

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 4/4

Page 30: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2 (class 5 on request)- tinned stranded copper conductor on request

2. Insulation- Mica tape- XLPE plastic EC 60092-351

3. Bedding- separator tape

4. Armour- copper wire braid, coverage > 90% IEC 60092-350- tinned copper wire braid on request

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

300

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

LKSM-FRHF

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Fire-resistant armoured powerand control cable 0,6/1kV

Page 31: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

28541 – 1x1,0 3,0 6,5 75 18 40

28568 – 1x1,5 3,0 7,0 80 23 40

28570 – 1x2,5 3,1 7,0 95 30 45

28572 – 1x4 3,1 8,0 115 40 45

28574 – 1x6 3,1 8,5 140 52 50

28576 – 1x10 3,5 10,0 195 72 60

28578 – 1x16 4,0 11,0 265 96 65

28580 – 1x25 4,9 13,0 380 127 80

28582 – 1x35 5,5 14,0 485 157 85

28584 – 1x50 8,7 16,0 655 196 95

28586 – 1x70 11,4 18,5 905 242 110

28588 – 1x95 11,5 20,5 1155 293 120

28590 – 1x120 14,5 22,5 1465 339 135

28592 – 1x150 14,7 25,0 1770 389 150

28594 – 1x185 15,2 27,5 2160 444 165

28596 – 1x240 18,2 30,5 2820 522 185

28598 – 1x300 18,7 33,5 3450 601 200

28542 – 2x1,0 3,5 10,0 120 15 60

28602 – 2x1,5 3,8 10,5 140 20 65

28604 – 2x2,5 4,3 11,5 170 26 70

28606 – 2x4 4,9 13,0 225 34 75

28608 – 2x6 5,4 14,0 340 44 85

28610 – 2x10 8,7 16,5 505 61 100

28612 – 2x16 10,0 19,0 690 82 115

28614 – 2x25 14,5 23,5 1055 108 140

28616 – 2x35 14,7 26,0 1325 133 155

28618 – 2x50 18,1 29,5 1715 167 175

28620 – 2x70 18,7 34,0 2325 206 205

28543 28544 3x1,0 4,1 10,5 145 13 60

28622 28623 3x1,5 4,1 11,0 170 16 65

28624 28625 3x2,5 4,6 12,0 210 21 75

28626 28627 3x4 5,2 13,5 280 28 80

28628 28629 3x6 5,8 15,0 400 36 90

28630 28631 3x10 9,3 17,5 595 50 105

28632 28633 3x16 10,7 20,0 835 67 120

28634 28635 3x25 14,6 25,0 1260 89 150

28636 28637 3x35 15,0 28,0 1605 110 165

28638 28639 3x50 18,3 31,5 2130 137 190

28640 28641 3x70 22,0 36,5 2920 169 220

28691 28692 3x95 22,8 40,5 3775 205 245

28693 28694 3x120 37,8 45,5 4875 237 275

310

,6/1

kV

CA

BLES

1/2

01

3

LKSM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

armourmm2

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Table continues on next pagePage 2/3

Page 32: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

320

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

28545 28546 4x1,0 4,1 11,0 170 13 65

28642 28643 4x1,5 4,5 12,0 200 16 70

28644 28645 4x2,5 5,0 13,5 255 21 80

28646 28647 4x4 5,7 14,5 335 28 90

28648 28649 4x6 8,8 16,5 505 36 100

28650 28651 4x10 10,3 19,5 725 50 115

28652 28653 4x16 11,9 22,5 1035 67 135

28654 28655 4x25 14,8 27,5 1535 89 165

28656 28657 4x35 18,1 30,5 2000 110 185

28658 28659 4x50 19,5 35,0 2635 137 210

28660 28661 4x70 22,4 40,0 3620 169 240

28703 28704 4x95 37,8 46,0 4895 205 275

28547 28548 5x1,0 4,5 12,0 195 10 70

28662 28663 5x1,5 5,0 13,5 245 13 80

28664 28665 5x2,5 5,6 14,5 305 17 85

28705 28706 5x4 8,6 16,5 440 23 100

28707 28708 5x6 9,7 18,0 600 30 110

28709 28710 5x10 11,5 21,0 870 42 125

28711 28712 5x16 13,2 24,5 1245 56 145

28713 28714 5x25 18,1 30,5 1875 74 180

28549 28550 7x1,0 4,9 13,0 240 9 80

28551 28552 10x1,0 8,7 16,5 355 8 100

28553 28554 12x1,0 9,0 17,0 395 8 100

28555 28556 14x1,0 11,4 18,0 455 7 105

28557 28558 16x1,0 11,4 19,0 505 7 115

28559 28560 19x1,0 11,4 20,0 555 7 120

28561 28562 24x1,0 12,5 23,5 695 6 140

28563 28564 27x1,0 12,8 24,0 750 6 145

28565 28566 37x1,0 14,4 26,5 960 5 160

28666 28667 7x1,5 5,4 14,5 295 12 85

28723 28724 10x1,5 9,6 18,0 430 11 110

28670 28671 12x1,5 9,9 19,0 490 10 115

28727 28728 14x1,5 11,4 20,0 555 10 120

28731 28732 16x1,5 11,5 21,0 610 9 125

28674 28675 19x1,5 11,7 22,0 680 9 130

28678 28679 24x1,5 13,9 26,0 875 8 155

28682 28683 27x1,5 14,1 26,5 945 8 160

28684 28685 37x1,5 16,0 29,5 1220 7 180

28668 28669 7x2,5 8,5 16,0 405 16 95

28725 28726 10x2,5 11,5 20,0 570 14 120

28672 28673 12x2,5 11,5 21,0 635 13 125

28729 28730 14x2,5 11,8 22,5 730 13 135

28733 28734 16x2,5 12,5 23,5 815 12 140

28676 28677 19x2,5 13,2 24,5 920 11 145

28680 28681 24x2,5 15,7 29,0 1165 10 175

28686 28687 27x2,5 16,1 29,5 1265 10 175

28688 28689 37x2,5 18,1 33,0 1660 9 200

LKSM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

armourmm2

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 3/3

Page 33: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

330

,6/1

kV

CA

BLES

1/2

01

3

Page 34: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

340

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LKAM-FRHF Fire-resistant screened powerand control cable 0,6/1kV

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- Mica tape IEC 60092-351- XLPE plastic

3. Screen- drain wire of tinned copper 1,0mm2 (in all sizes)

- aluminium polyester tape, IEC 60092-350 coverage 100%

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Application: For fixed installation in most areas and on open deck in ships,especially when lightweight cables are needed.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage AC 0,6/1kV (1,2kV)DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 35: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

350

,6/1

kV

CA

BLES

1/2

01

3

LKAM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mmNormal G-type

28741 – 2x1,5 9,5 115 20 6028743 28744 3x1,5 10,5 140 16 6028747 28748 4x1,5 11,0 165 16 6528751 28752 5x1,5 12,0 200 13 7528755 – 7x1,5 13,5 250 12 8028763 – 12x1,5 17,5 400 10 10528767 – 14x1,5 18,5 450 10 11028771 – 16x1,5 19,5 515 9 12028775 – 19x1,5 20,5 580 9 12528779 – 24x1,5 24,5 740 8 14528783 – 27x1,5 25,0 810 8 150

28742 – 2x2,5 10,5 140 26 6528745 28746 3x2,5 11,5 175 21 7028749 28750 4x2,5 12,5 215 21 7528753 28754 5x2,5 13,5 270 17 8028769 – 14x2,5 20,5 625 13 12528773 – 16x2,5 22,0 700 12 13028777 – 19x2,5 23,5 820 11 14028781 – 24x2,5 27,5 1035 10 16528785 – 27x2,5 28,0 1140 10 170

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 36: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

362

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

LKM-HF Unarmoured control andinstrumentation cable250V

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended..

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 37: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

27821 2x0,5 6,0 40 8,7 25

27822 3x0,5 6,5 50 7,6 25

27823 4x0,5 7,0 60 6,9 30

27824 5x0,5 7,5 70 6,4 30

27825 7x0,5 8,0 85 5,8 30

27826 10x0,5 10,5 125 5,1 40

27827 12x0,5 10,5 140 4,8 45

27828 14x0,5 11,0 160 4,6 45

27829 16x0,5 12,0 175 4,4 45

27830 19x0,5 12,5 200 4,1 50

27831 20x0,5 13,5 220 4,1 55

27832 24x0,5 14,5 250 3,8 60

27833 27x0,5 15,0 275 3,7 60

27834 32x0,5 15,5 310 3,5 60

27835 37x0,5 16,5 350 3,3 65

26365 2x0,75 6,5 50 11,3 25

26366 3x0,75 7,0 60 9,8 30

26367 4x0,75 7,5 75 8,9 30

26368 5x0,75 8,0 85 8,3 30

26369 7x0,75 8,5 110 7,4 35

26370 10x0,75 11,0 160 6,6 45

26371 12x0,75 11,5 180 6,2 45

26372 14x0,75 12,0 200 5,9 50

26373 16x0,75 13,0 235 5,6 50

26374 19x0,75 13,5 265 5,3 55

26375 20x0,75 14,5 285 5,2 60

26376 24x0,75 16,0 335 4,9 65

26377 27x0,75 16,5 365 4,7 65

26378 32x0,75 17,0 415 4,5 65

26379 37x0,75 18,0 470 4,3 70

372

50

V C

AB

LES1

/20

13

LKM-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

Other sizes on request.

Page 38: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Armour- drain wire copper (in all sizes)- copper wire braid, coverage > 90% IEC 60092-350- tinned copper wire braid on request

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

382

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

LKSM-HF Armoured control andinstrumentation cable250V

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Page 39: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

392

50

V C

AB

LES1

/20

13

LKSM-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

27779 2x0,5 3,1 7,0 80 8,7 4027780 3x0,5 3,1 7,5 85 7,6 4527781 4x0,5 3,1 8,0 95 6,9 4527782 5x0,5 3,2 8,5 110 6,4 5027783 7x0,5 3,5 9,0 125 5,8 5527784 10x0,5 4,6 11,5 180 5,1 7027785 12x0,5 4,8 11,5 195 4,8 7027786 14x0,5 5,1 12,0 215 4,6 7027787 16x0,5 5,5 12,5 235 4,4 7527788 19x0,5 5,8 13,5 265 4,1 8027789 20x0,5 6,1 14,0 285 4,1 8527790 24x0,5 6,8 15,5 325 3,8 9027791 27x0,5 6,9 15,5 345 3,7 9527792 32x0,5 9,9 16,5 420 3,5 10027793 37x0,5 10,9 18,0 470 3,3 10526402 2x0,75 3,6 7,5 90 11,3 4526403 3x0,75 3,6 7,5 100 9,8 4526404 4x0,75 3,6 8,5 115 8,9 5026405 5x0,75 4,1 9,5 140 8,3 5526407 7x0,75 4,1 10,0 165 7,4 6026410 10x0,75 5,1 12,5 220 6,6 7526412 12x0,75 5,3 12,5 245 6,2 7526414 14x0,75 5,6 13,0 270 5,9 8026416 16x0,75 6,1 14,0 300 5,6 8526419 19x0,75 6,3 14,5 330 5,3 8526420 20x0,75 11,0 18,0 455 5,2 11026424 24x0,75 11,7 17,0 450 4,9 10026427 27x0,75 11,7 17,5 485 4,7 10526432 32x0,75 11,8 18,0 545 4,5 11026437 37x0,75 11,9 19,5 605 4,3 115

Cross-section of

armourmm2

Other sizes on request.

Page 40: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

402

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Screen- drain wire of tinned copper- aluminium polyester tape, coverage 100% IEC 60092-350

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships, especially when lightweight cables are needed.

If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

LKAM-HF Screened control andinstrumentation cable 250V

Page 41: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

412

50

V C

AB

LES1

/20

13

26440 2x0,5 6,0 45 8,7 25

26441 3x0,5 6,5 55 7,6 25

26442 4x0,5 7,0 65 6,9 30

26443 5x0,5 7,5 75 6,4 30

26444 7x0,5 8,0 90 5,8 30

26445 10x0,5 10,5 130 5,1 40

26446 12x0,5 11,0 145 4,8 45

26447 14x0,5 11,5 165 4,6 45

26448 16x0,5 12,0 180 4,4 45

26449 19x0,5 12,5 205 4,1 50

26450 20x0,5 13,5 225 4,1 55

26451 24x0,5 14,5 260 3,8 60

26452 27x0,5 15,0 280 3,7 60

26453 32x0,5 15,5 325 3,5 60

26454 37x0,5 16,5 365 3,3 65

26382 2x0,75 6,5 55 11,3 25

26383 3x0,75 7,0 65 9,8 30

26384 4x0,75 7,5 80 8,9 30

26385 5x0,75 8,0 95 8,3 30

26386 7x0,75 9,0 120 7,4 35

26387 10x0,75 11,5 165 6,6 45

26388 12x0,75 12,0 190 6,2 45

26389 14x0,75 12,5 215 5,9 50

26390 16x0,75 13,0 240 5,6 50

26391 19x0,75 13,5 270 5,3 55

26392 20x0,75 17,0 345 5,2 70

26393 24x0,75 16,0 340 4,9 65

26394 27x0,75 16,5 370 4,7 65

26395 32x0,75 17,0 430 4,5 70

26396 37x0,75 18,5 485 4,3 75

LKAM-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

Other sizes on request.

Page 42: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

422

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Twisted pair- two insulated cores twisted together to form a pair See next page for Quad

4. Bedding- filler tape

5. Armour- drain wire copper (in all sizes)

- copper wire braid, coverage > 94% IEC 60092-350- tinned copper wire braid on request

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Armoured instrumentation andcommunication cable 250VRFE-HF

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data:

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,5mm2 0,75mm2 1,5mm2 Unit

80 52 24,4 ohm/km

55 50 60 nF/km

0,6 0,6 0,7 mH/km

≥1500 ≥1500 ≥1500 Mohm/km

Page 43: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

432

50

V C

AB

LES1

/20

13

RFE-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20362 1x2x0,5 7,0 85 4520364 2x2x0,5 Quad 8,0 105 5020363 2x2x0,5 10,5 130 6020366 4x2x0,5 11,5 175 7020368 7x2x0,5 14,0 245 8520369 8x2x0,5 14,5 270 8520370 10x2x0,5 17,0 355 10020371 12x2x0,5 17,5 390 10520372 14x2x0,5 18,5 440 11020373 16x2x0,5 19,5 485 12020374 19x2x0,5 21,0 545 12520376 24x2x0,5 23,5 670 14020378 37x2x0,5 28,0 930 17020382 1x2x0,75 7,5 95 4520384 2x2x0,75 Quad 9,0 125 5520383 2x2x0,75 11,0 155 6520386 4x2x0,75 12,5 215 7520388 7x2x0,75 15,5 330 9020389 8x2x0,75 16,0 375 9520390 10x2x0,75 18,5 440 11020391 12x2x0,75 19,0 490 11520392 14x2x0,75 20,5 565 12520393 16x2x0,75 21,5 620 13020394 19x2x0,75 23,5 715 14020396 24x2x0,75 26,0 860 15520398 32x2x0,75 29,5 1100 17520490 1x2x1,5 9,5 135 6020491 2x2x1,5 Quad 11,0 190 6520492 2x2x1,5 14,0 235 8520493 4x2x1,5 17,0 375 10020494 7x2x1,5 20,0 545 12020495 8x2x1,5 21,5 625 13020496 10x2x1,5 24,5 760 14520497 12x2x1,5 25,5 855 15520498 14x2x1,5 27,0 960 16520499 19x2x1,5 31,0 1230 18520500 24x2x1,5 35,0 1530 21020501 32x2x1,5 39,5 1950 235

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

(Quad)cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue

Page 44: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

442

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Twisted pair & pair screen- two insulated cores twisted together to form a pair- plastic coated aluminium tape and a tinned copper drain wire

4. Bedding- filler tape

5. Armour- drain wire copper (in all sizes)

- copper wire braid, coverage > 94% IEC 60092-350- tinned copper wire braid on request

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Armoured and pair screenedinstrumentation andcommunication cable 250V

RFE-HF (i)

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data:Loop resistance of pair, max. / +20°CPair capacitance, nom. / 800HzLoop inductance, nom.Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,75mm2 1,5mm2 Unit

52 24,4 ohm/km

70 90 nF/km

0,6 0,7 mH/km

≥1500 ≥1500 Mohm/km

Page 45: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

452

50

V C

AB

LES1

/20

13

RFE-HF(i) 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

22006 1x2x0,75 7,5 95 4522008 1x4x0,75 9,0 140 5522010 2x2x0,75 11,5 170 7022012 4x2x0,75 13,0 240 7522014 7x2x0,75 15,5 375 9522016 8x2x0,75 16,5 420 10022018 10x2x0,75 19,0 520 11522020 12x2x0,75 20,0 585 12022022 14x2x0,75 21,0 650 12522024 19x2x0,75 24,0 835 14522026 24x2x0,75 27,0 1035 16022050 1x2x1,5 10,0 145 6022052 1x4x1,5 11,0 200 6522054 2x2x1,5 14,5 255 8522056 4x2x1,5 17,0 415 10022058 7x2x1,5 20,0 610 12022060 8x2x1,5 22,0 700 13022062 10x2x1,5 25,0 855 15022064 12x2x1,5 26,0 965 15522066 14x2x1,5 28,0 1105 16522068 19x2x1,5 32,0 1440 190

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

Page 46: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

462

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Twisted pair- two insulated cores twisted together to form a pair See next page for Quad

4. Screen- drain wire tinned copper- aluminium polyester tape IEC 60092-350 coverage 100%

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Screened instrumentationand communication cable 250VRFA-HF

Application: For fixed installation in most areas and on open deck in ships, especiallywhen lightweight cables are needed. If the cable is exposed to directsun light protective covering or cable with black outer sheath isrecommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,5mm2 0,75mm2 Unit

80 52 ohm/km

55 50 nF/km

0,6 0,6 mH/km

≥1500 ≥1500 Mohm/km

Page 47: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

472

50

V C

AB

LES1

/20

13

RFA-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20910 1x2x0,5 6,0 45 3520912 2x2x0,5 Quad 7,0 65 4020914 2x2x0,5 9,0 75 5520916 4x2x0,5 10,5 120 6520918 7x2x0,5 12,5 175 7520920 8x2x0,5 13,5 200 8020922 10x2x0,5 15,5 245 9520924 12x2x0,5 16,0 280 9520926 14x2x0,5 17,5 315 10520928 16x2x0,5 18,0 350 11020930 19x2x0,5 20,0 410 12020932 24x2x0,5 22,0 515 13520934 32x2x0,5 25,5 665 15020936 37x2x0,5 27,0 745 16020970 1x2x0,75 6,5 55 4020972 2x2x0,75 Quad 7,5 80 4520974 2x2x0,75 10,0 100 6020976 4x2x0,75 11,5 150 7020978 7x2x0,75 14,0 225 8520980 8x2x0,75 15,0 260 9020982 10x2x0,75 17,0 320 10020984 12x2x0,75 18,0 365 10520986 14x2x0,75 19,0 415 11520988 16x2x0,75 20,5 480 12520990 19x2x0,75 22,0 555 13020992 24x2x0,75 24,5 680 145

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

(Quad)cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue

Page 48: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- XLPE plastic IEC 60092-351

3. Twisted pair & pair screen- two insulated cores twisted together to form a pair- plastic coated aluminium tape and a tinned copper drain wire

4. Bedding- separator tape

5. Collective screen- drain wire tinned copper IEC 60092-350- aluminium polyester tape, coverage 100%

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Application: For fixed installation in most areas and on open deck in ships, especiallywhen lightweight cables are needed. If the cable is exposed to directsun light protective covering or cable with black outer sheath isrecommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom.

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

482

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

RFA-HF (i) Collectively and pair screenedinstrumentation andcommunication cable 250V

0,5mm2 0,75mm2 Unit

80 52 ohm/km

55 70 nF/km

0,6 0,6 mH/km

≥1500 ≥1500 Mohm/km

Page 49: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

492

50

V C

AB

LES1

/20

13

Other sizes on request.

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

The pairs are covered by a numbered tape (1, 2, 3, 4, 5....)

RFA-HF(i) 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20940 2x2x0,5 9,5 95 5520942 4x2x0,5 11,0 145 6520944 7x2x0,5 13,0 220 8020946 8x2x0,5 14,0 245 8520948 10x2x0,5 16,0 305 9520950 12x2x0,5 16,5 350 10020952 14x2x0,5 17,5 395 10520954 16x2x0,5 19,0 450 11520956 19x2x0,5 20,0 520 12020958 24x2x0,5 22,5 655 13521059 2x2x0,75 10,0 115 6021061 4x2x0,75 12,0 180 7021063 7x2x0,75 14,5 275 8521065 8x2x0,75 15,0 310 9021067 10x2x0,75 17,5 380 10521069 12x2x0,75 18,0 440 11021071 14x2x0,75 19,5 520 12021073 16x2x0,75 21,0 580 12521075 19x2x0,75 22,5 680 13521077 24x2x0,75 25,0 840 150

Page 50: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

502

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

LKM-FRHF Fire-resistant unarmouredcontrol and instrumentationcable 250V

Page 51: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

22406 2x0,75 8,5 65,0 11,3 35

22407 3x0,75 9,0 80,0 9,8 35

22408 4x0,75 10,0 110,0 8,9 40

22409 5x0,75 11,0 130,0 8,3 45

22410 7x0,75 11,5 160,0 7,4 45

22411 10x0,75 15,0 225,0 6,6 60

22412 12x0,75 15,5 255,0 6,2 60

22413 14x0,75 16,5 295,0 5,9 65

22414 16x0,75 17,5 330,0 5,6 70

22415 19x0,75 18,0 375,0 5,3 75

22416 20x0,75 19,0 410,0 5,2 75

22417 24x0,75 21,5 475,0 4,9 85

22418 27x0,75 22,0 520,0 4,7 85

22419 32x0,75 23,0 615,0 4,5 90

22420 37x0,75 25,0 695,0 4,3 100

Other size on request.

512

50

V C

AB

LES1

/20

13

LKM-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

Page 52: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- Mica tape- XLPE plastic EC 60092-351

3. Bedding- separator tape

4. Armour- drain wire copper (in all sizes)

- copper wire braid, coverage > 90% IEC 60092-350- tinned copper wire braid on request

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

522

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

LKSM-FRHF

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Fire-resistant armouredcontrol and instrumentationcable 250V

Page 53: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

532

50

V C

AB

LES1

/20

13

22436 2x0,75 3,6 9,0 105 11,3 55

22437 3x0,75 3,9 9,5 125 9,8 60

22438 4x0,75 4,4 11,0 160 8,9 65

22439 5x0,75 4,9 11,5 185 8,3 70

22440 7x0,75 5,4 12,5 220 7,4 75

22441 10x0,75 7,1 16,0 300 6,6 95

22442 12x0,75 7,3 16,0 330 6,2 95

22443 14x0,75 7,8 17,0 370 5,9 100

22444 16x0,75 11,3 18,5 445 5,6 110

22445 19x0,75 11,9 19,5 495 5,3 115

22446 20x0,75 12,9 20,5 545 5,2 125

22447 24x0,75 14,3 22,5 615 4,9 135

22448 27x0,75 14,6 23,0 665 4,7 140

22449 32x0,75 15,3 23,5 740 4,5 140

22450 37x0,75 16,7 26,0 860 4,3 155

Other size on request.

LKSM-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

Cross-section of

armourmm2

Page 54: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- Mica tape IEC 60092-351- XLPE plastic

3. Screen- drain wire of tinned copper- aluminium polyester tape, IEC 60092-350 coverage 100%

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

542

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LKAM-FRHF Fire-resistant screened controland instrumentation cable 250V

Application: For fixed installation in most areas and on open deck in ships,especially when lightweight cables are needed.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 55: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

552

50

V C

AB

LES1

/20

13

LKAM-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

CurrentRating Aat +45°C

Min. bendingradius fixedinstallation

mm

22466 2x0,75 8,5 70 11,3 50

22467 3x0,75 9,0 85 9,8 55

22468 4x0,75 10,0 115 8,9 60

22469 5x0,75 11,0 135 8,3 65

22470 7x0,75 11,5 165 7,4 70

22471 10x0,75 15,0 230 6,6 90

22472 12x0,75 15,5 260 6,2 95

22473 14x0,75 16,5 300 5,9 100

22474 16x0,75 17,5 340 5,6 105

22475 19x0,75 18,0 380 5,3 110

22476 20x0,75 19,5 415 5,2 115

22477 24x0,75 21,5 480 4,9 130

22478 27x0,75 22,0 525 4,7 130

22479 32x0,75 23,0 620 4,5 140

22480 37x0,75 25,0 700 4,3 150

Other size on request.

Page 56: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Twisted pair- two insulated cores twisted together to form a pair See next page for Quad

4. Bedding- filler tape

5. Armour- drain wire (in all sizes)

- copper wire braid, coverage > 94% IEC 60092-350- tinned copper wire braid on request

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

562

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Fire-resistant armouredinstrumentation andcommunication cable 250V

RFE-FRHF

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,75mm2 1,5mm2 Unit

52 24,4 ohm/km

45 55 nF/km

0,6 0,7 mH/km

≥1500 ≥1500 Mohm/km

Page 57: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

572

50

V C

AB

LES1

/20

13

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

(Quad)cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue

RFE-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20520 1x2x0,75 9,5 115 5520522 2x2x0,75 Quad 11,0 170 6520524 2x2x0,75 14,0 210 8520526 4x2x0,75 16,5 330 10020528 7x2x0,75 20,0 470 12020530 8x2x0,75 21,0 515 12520532 10x2x0,75 24,5 640 14520534 12x2x0,75 25,5 710 15020536 14x2x0,75 27,0 810 16520538 19x2x0,75 31,0 1025 18520540 24x2x0,75 34,5 1260 20520542 32x2x0,75 39,4 1605 23520575 1x2x1,5 10,5 155 6520577 2x2x1,5 Quad 12,0 220 7020579 2x2x1,5 16,0 315 9520581 4x2x1,5 18,5 430 11020583 7x2x1,5 22,5 655 13520585 8x2x1,5 24,0 725 14520587 10x2x1,5 27,5 880 16520589 12x2x1,5 29,0 1010 17520591 14x2x1,5 30,5 1135 18520593 16x2x1,5 33,0 1290 19520595 19x2x1,5 35,2 1475 210

Page 58: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Twisted pair & pair screen- two insulated cores twisted together to form a pair- plastic coated aluminium tape and a tinned copper drain wire

4. Bedding- filler tape

5. Armour- drain wire copper- copper wire braid, coverage > 94% IEC 60092-350- tinned copper wire braid on request

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

582

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Fire-resistant armoured andpair screened instrumentationand communication cable 250V

RFE-FRHF (i)

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,75mm2 1,5mm2 Unit

52 24,4 ohm/km

55 75 nF/km

0,6 0,7 mH/km

≥1500 ≥1500 Mohm/km

Page 59: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

592

50

V C

AB

LES1

/20

13

RFE-FRHF(i) 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20546 1x2x0,75 9,5 125 5520548 1X4X0,75 11,0 175 6520550 2x2x0,75 14,5 225 8520552 4x2x0,75 17,0 355 10020554 7x2x0,75 20,0 510 12020556 8x2x0,75 22,0 585 13020558 10x2x0,75 25,0 710 15020560 12x2x0,75 26,0 800 15520562 14x2x0,75 27,5 910 16520564 19x2x0,75 32,0 1175 19020566 24x2x0,75 35,0 1425 21020568 32x2x0,75 41,0 1945 24520603 1x2x1,5 10,5 165 6520604 1X4X1,5 12,0 225 7520605 2x2x1,5 16,5 320 10020607 4x2x1,5 19,0 475 11520609 7x2x1,5 23,0 720 13520611 8x2x1,5 24,5 805 14520613 10x2x1,5 28,0 985 16520615 12x2x1,5 29,5 1145 17520617 14x2x1,5 31,5 1290 19020619 16x2x1,5 33,5 1450 20020621 19x2x1,5 36,0 1665 215

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

Page 60: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

602

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Twisted pair- two insulated cores twisted together to form a pair See next page for Quad

4. Screen- drain wire tinned copper- aluminium polyester tape, coverage 100% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Fire-resistant screenedinstrumentation andcommunication cable 250V

RFA-FRHF

0,75mm2 Unit

52 ohm/km

45 nF/km

0,6 mH/km

≥1500 Mohm/km

Page 61: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

612

50

V C

AB

LES1

/20

13

RFA-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20635 1x2x0,75 8,5 75 5020637 2x2x0,75 Quad 10,0 120 6020639 2x2x0,75 13,0 135 8020641 4x2x0,75 15,5 215 9020643 7x2x0,75 18,5 330 11020645 8x2x0,75 20,0 380 12020647 10x2x0,75 23,0 480 14020649 12x2x0,75 24,0 545 14520651 14x2x0,75 25,5 620 15520653 16x2x0,75 27,5 700 16520655 19x2x0,75 29,5 805 17520657 24x2x0,75 33,5 1030 20021521 1x2x1,5 9,0 100 55

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

(Quad)cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue

Page 62: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2- tinned stranded copper conductor on request

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Twisted pair & pair screen- two insulated cores twisted together to form a pair- plastic coated aluminium tape and a tinned copper drain wire

4. Bedding- separator tape

5. Collective screen- drain wire tinned copper- aluminium polyester tape coverage 100 % IEC 60092-350

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

622

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Fire-resistant collectively andpair screened instrumentationand communication cable 250V

RFA-FRHF (i)

0,75mm2 Unit

52 ohm/km

55 nF/km

0,6 mH/km

≥1500 Mohm/km

Page 63: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

632

50

V C

AB

LES1

/20

13

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

RFA-FRHF(i) 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20667 2x2x0,75 13,5 155 8020669 4x2x0,75 15,5 245 9520671 7x2x0,75 18,5 380 11020673 8x2x0,75 20,0 430 12020675 10x2x0,75 23,5 545 14020677 12x2x0,75 24,5 625 14520679 14x2x0,75 26,0 725 15520681 16x2x0,75 28,0 810 16520683 19x2x0,75 30,0 945 18020685 24x2x0,75 34,0 1205 20521553 2x2x1,5 15,0 215 9021555 4x2x1,5 17,5 350 105

Page 64: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

64O

PTI

CA

L FI

BR

E CA

BLE

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

1/2

01

3

Cable construction:

1. Central element glass fibre, 1,5 mm

2. PP-slotted core, 6,0 mm

3. Optical fibres, 250 μm

4. Swellable tape

5. Rip cord

6. UV-protected and halogen free sheath

FXMSU Optical fibreindoor/outdoor cable

- non-metallic

- networks in marine applications

- Fibres: 250 μm SM or MM fibres

- 4 - 48 fibres

Cable characteristics:

Maximum pulling force 500 N EN 187000 method 501

Crush strength / 100 mm (plate) 4000 N EN 187000 method 504

Crush strength / 25 mm (mandrel) 650 N EN 187000 method 504

Impact strength 25 J EN 187000 method 505

Sheath marking Cable type, manufacturer's name,manufacturing number and time,length marking in meter

Minimum installation temperature -15 °C

Operating temperature range -45...+70 °C

Longitudinal water tightness EN 187000 method 605B

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

�. Slotted corecables haveblue and redmarker threadsfor the first andlast slotrespectively.

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Page 65: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

FXMSU

Partnumber

Cable and number offibres

Diameterof slotted

core,

mm

10001 FXMSU 1X4SML (L)

10022 FXMSU 1X6SML (L)

10024 FXMSU 2X6SML (L)

10028 FXMSU 4X6SML (L)

14384 FXMSU 1X4OM3L (L)

14386 FXMSU 2X4OM3L (L)

14388 FXMSU 3X4OM3L (L)

14398 FXMSU 4X6OM3L (L)

14404 FXMSU 1X4GKL (L)

14406 FXMSU 1X6GKL (L)

14408 FXMSU 2X4GKL (L)

14410 FXMSU 3X4GKL (L)

14412 FXMSU 4X4GKL (L)

14416 FXMSU 4X6GKL (L)

14420 FXMSU1X4SML+1X4GKL (L)

14422 FXMSU1X4SML+2X4GKL (L)

14424 FXMSU2X4SML+2X4GKL (L)

14426 FXMSU1X6SML+3X4GKL (L)

14428 FXMSU2X6SML+3X4GKL (L)

14449 FXMSU1X4SML+1X4OM3 (L)

14450 FXMSU1X4SML+2X4OM3L (L)

14451 FXMSU2X4SML+2X4OM3L (L)

14454 FXMSU1X6SML+3X4OM3L (L)

14455 FXMSU2X6SML+3X4OM3L (L)

Other fiber combinations on request

Nominalouter

diameter,

mm

Approximateweight,kg/km

duringinstallation,

mm

finalinstallation,

mm

Minimum bending radius

65O

PTIC

AL FIB

RE C

AB

LE1

/20

13

6 9,4 75 140 100

Page 66: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

- For tray installation- Fibres: 2–8 SM or MM fibres, 900 μm- Connectors can be mounted directly to the fibres

Cable characteristics:Maximum pulling force 1500 N EN 187000 method 501Crush strength / 100 mm (plate) 4000 N EN 187000 method 504Crush strength / 25 mm (mandrel) 750 N EN 187000 method 504Impact strength, R = 300 mm 30 J EN 187000 method 505Sheath marking Cable type, manufacturer's name,

manufacturing number and time,length marking in meter

Minimum bending radius 195 mm during installation, 130 mm in final bendingNominal cable diameter 13.1 mmCable weight 142 kg/kmMinimum installation temperature -15 °COperating temperature range -45...+70 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

Cable construction:

1. FRP central element 2 mm

2. PP-slotted core

3. Installation cable unit FMS 1 (2 mm)

4. Fire barrier tape

5. Rip cord

6. Halogen free sheath 1,5 mm

FXMMS Optical fibreinstallation cable

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

66O

PTI

CA

L FI

BR

E CA

BLE

1/2

01

3

Cable and number offibres

Diameterof slotted

core,

mm

FXMMS 2-4 7,5 10,7 102 160 110

FXMMS 6-8 9,7 13,1 142 195 130

Nominalouter

diameter,

mm

Approximateweight,kg/km

duringinstallation,

mm

finalinstallation,

mm

Minimum bending radius

Page 67: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

67O

PTIC

AL FIB

RE C

AB

LE1

/20

13

FXMMS

Partnumber

Cable and number offibres

Diameterof slotted

core,

mm

10810 FXMMS 2SMT (2MM) 7,5 10,7 102 160 110

10812 FXMMS 4SMT (2MM) 7,5 10,7 102 160 110

10814 FXMMS 6SMT (2MM) 9,7 13,1 142 195 130

10816 FXMMS 8SMT (2MM) 9,7 13,1 142 195 130

13747 FXMMS 2GKT (2MM) 7,5 10,7 102 160 110

13748 FXMMS 4GKT (2MM) 7,5 10,7 102 160 110

13749 FXMMS 6GKT (2MM) 9,7 13,1 142 195 130

13750 FXMMS 8GKT (2MM) 9,7 13,1 142 195 130

13872 FXMMS 2OM3T (2MM) 7,5 10,7 102 160 110

13874 FXMMS 4OM3T (2MM) 7,5 10,7 102 160 110

13876 FXMMS 6OM3T (2MM) 9,7 13,1 142 195 130

13878 FXMMS 8OM3T (2MM) 9,7 13,1 142 195 130

Nominalouter

diameter,

mm

Approximateweight,kg/km

duringinstallation,

mm

finalinstallation,

mm

Minimum bending radius

Page 68: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

68O

PTI

CA

L FI

BR

E CA

BLE

1/2

01

3

Cabled optical fibres characteristicsFibre coating: L = 250 μm ± 10 μm

T = 900 μm ± 50 μm

Single mode fibre 10/125 μm SM / OS2 (ITU-T G.652.D)

Fibre type SML 250μm±10μmSMT 900μm±50μm

Mode field diameter (MFD) 1310 nm 9,3 +/- 0,5 μm

Mode field eccentricity ≤ 1,0 μm

-Installation cables ≤ 0,5 μm

Cladding diameter 125 +/- 2 μm

- Installation cables 125 +/- 1 μm

Cladding ellipticity ≤ 2 %

Fibre attenuation 1310 nm ≤ 0,40 dB/km

1550 nm ≤ 0,25 dB/km

Zero dispersion range 1300...1324 nm

Dispersion coefficient ≤ 0,093 ps/nm2/km

- Dispersion at 1550 nm ≤ 18 ps/nm/km

Cut-off wavelength ≤ 1260 nm

- Installation cables 1180...1250 nm

Polarization mode dispersion ≤ 0,5 ps/√km

Proof test 1 % / 1 sec

Fibre identification 6 colour systemaccording to SFS 5648

Multi mode fibre 50/125 μm OM3

Fibre type OM3L 250μm±10μmOM3T 900μm±50μm

Core diameter 50 +/- 3 μm

Core ellipticity ≤ 6 %

Core eccentricity ≤ 3 μm

Cladding diameter 125 +/- 2 μm

Cladding ellipticity ≤ 2 %

Fibre attenuation 850 nm ≤ 2,7 dB/km

1300 nm ≤ 0,8 dB/km

Bandwidth 850 nm ≥ 1500 MHz x km (LED)

1300 nm ≥ 500 MHz x km (LED)

850 nm ≥ 2000 MHz x km (Laser)

Numerical aperture, NA 0,200 +/- 0,015

Fibre identification 6 colour systemaccording to SFS 5648

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Page 69: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

69O

PTIC

AL FIB

RE C

AB

LE1

/20

13

Multi mode fibre 62,5/125 μm GK / OM1

Fibre type GKL 250μm±10μmGKT 900μm±50μm

Core diameter 62,5 +/- 3 μm

Core ellipticity ≤ 6 %

Core eccentricity ≤ 3 μm

Cladding diameter 125 +/- 2 μm

Cladding ellipticity ≤ 2 %

Fibre attenuation 850 nm ≤ 3,5 dB/km

1300 nm ≤ 1,0 dB/km

Bandwidth 850 nm ≥ 200 MHz x km

1300 nm ≥ 500 MHz x km

Numerical aperture, NA 0,275 +/- 0,015

Fibre identification 6 colour systemaccording to SFS 5648

Page 70: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

Amount of Category burning Burning time

material

A 7 litres/m 40 min

B 3,5 litres/m 40 min

C 1,5 litres/m 20 min

Un3A

70TE

CHNI

CAL

INFO

RMAT

ION

1/2

01

3

All Helkama cables comply with the mostsevere requirements ofcategory A.

Test on

bunched

cables

IEC 60332-3

Burning isallowed upto max. 2.5meters fromthe burnerwithinspecified time.

IEC 60332-1 is the test for single insu-lated wire and cable. Test procedure andrequirements according to the picturebelow.

Halogen-free

Halogen-free refers to the absenceof halogens, such as chlorine andfluorine, and is determined onthe basis of halogen content andthe acidity of gases of a cable.

IEC 60754-1 determines thehalogen content of the material.To meet the requirements ashalogen-free the halogen contentof the material may not exceed0,5 % or 5 mg/g.

IEC 60754-2 determines thedegree of acidity of gases evolvedduring combustion. The limitvalues are 4,3 for pH and10 mikroS for conductivity.

Smoke emission

Smoke emission refers to visibilityin a fire. The greater the light trans-mittance, the better the visibility.When tested in accordance withIEC 61034-1 (test method) andIEC 61034-2 (test requirements)the smoke emission of a cable duringfire must not exceed the following values.

Requirements:60 % lighttransmittance

27m3 cubesmoke chamber

Min. 50 mm of the cable, measured fromthe upper support, must remain unburnedafter the specified time.

475 550 600mm mm mm

50 mm

3.5

m

1 m

4 m

2.5

m

2 m

Insulation material:

The following designations are used forinsulation materials in this catalog.All materials are halogen-free.

XLPE stands for cross-linked poly-ethylene compound. It has excellentmechanical and electrical characteristics.

Sheathing material:

The designation SHF1 stands forthermoplastic compound. This materialis halogen-free, highly flame-retardantand has low smoke emission.

Definition of terms:

Flame-retardant

To be flame-retardant, the cablesmust withstand the test specified inIEC standard 60332-3 or IEC 60332-1.Flame-retardant cables do not propagatefire, and are self-extinguishing.

IEC 60332-3 is the test for bunched wiresand cables and has three categories A,B and C, defined by different limits forflammable material and burning times.Burning time describes how long theburner is directed towards the bunch ofcables. The requirement for passing thetest is that after the burner has beenremoved the cables must extinguishthemselves. Burning may not occur morethan 2.5 m from the burner as shown inthe figure.

GENERAL INFORMATION

Fire-resistant

IEC 60331-1 Test method for fire withshock at a temperature of at least830 °C for cables of rated voltage up toand including 0,6/1,0 kV and with anoverall diameter exceeding 20 mm.

IEC 60331-2 Test method for fire withshock at a temperature of at least830 °C for cables of rated voltage up toand including 0,6/1,0 kV and with anoverall diameter not exceeding 20 mm.

830 °C / 90 min

gas burner500 mm

110 mm

Page 71: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

71TECHNICAL INFORM

ATION1

/20

13

LKM-HF During installation R = 6x D < 25mmLKMM-HF During installation R = 9x D > 25mmLKEM-HF Fixed installation R = 4x D < 25mm

Fixed installation R = 6x D > 25mmLKSM-HF During installation R = 9x DLKSM-EMC Fixed installation R = 6x DLKSM-VFDLKMSM-HFLKAM-HFLKM-FRHFLKSM-FRHFLKAM-FRHFRFE-HFRFE-HF(i)RFA-HFRFA-HF(i)RFE-FRHFRFE-FRHF(i)RFA-FRHFRFA-FRHF(i)

DIAMETER TOLERANCE Cable outer diameter, mm. Tolerance1 – 10 ±0,5mm

10,1 – 20 ±1,0mm20,1 – 30 ±1,5mm

Cable outer diameter, mm. Tolerance30,1 – 40 ±2,0mm40,1 – 50 ±2,5mm50,1 – 60 ±3,0mm

Recommended minimum bending

radius, ( R ) :

Radius (R)

Outer

diameter (D)

250V

a bPair number1 1 22 3 43 5 64 7 85 9 106 11 12etc.

CORE IDENTIFICATION (according to HD 308 S2)

BU = Blue, BN = Brown, BK = Black, GY = Grey, Y/G = Yellow/Green

1 2

250V

LKSM-HF

Black numbers on white base4-coresto 37-cores

3-cores

2-cores

2

3

1

Black numbers on white base

Black numbers on white base

Black numberson white base

Black numberson white base

Last coreyellow/green.

BU

BN

Y/G

0,6/1kV Normal type G-type(with earthconductor)

1-core

2-cores

3-cores

4-cores

5-cores

7-coresand above

6

71

23

45

12

34

5BU

BKBN

GY

Y/G

61

23

45

Y/G

BK

BN BU

BKGY

BNBU

GY

BN BK

BN

GY

Y/G

BK

1,8/3kV LKSM-VFD

BK

GY

BN BK

Y/GGY

BN BKY/G

Y/G

1-core

3-cores

3-cores+ 3-groundcores

BENDING RADIUS

Page 72: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

72TE

CHNI

CAL

INFO

RMAT

ION

1/2

01

3

CURRENT RATING

"Current rating (A) at an ambient temperature of 45°Caccording to the standard IEC 60092-3520,6/1 kV +90°C marine cables."

Current carrying capacities in continous service atmaximum rated conductor temperature of +90°C.

For continuous service. Continuous service for a cable isto be considered as a current-carrying service (withconstant load) having a duration longer than three timesthe thermal time constant of the cable, i.e. longer thanthe critical duration(see short time duty).

Size 1 2 3 4 5 7 10 12 14 16 19 24 27 37

Factor, n 1 0,85 0,7 0,7 0,58 0,52 0,46 0,44 0,41 0,40 0,37 0,35 0,33 0,301,0mm2 18 15 13 13 10 9 8 8 7 7 7 6 6 51,5mm2 23 20 16 16 13 12 11 10 9 9 9 8 7 72,5mm2 30 26 21 21 17 16 14 13 12 12 11 11 10 94mm2 40 34 28 28 236mm2 52 44 36 36 3010mm2 72 61 50 50 4216mm2 96 82 67 67 5625mm2 127 108 89 89 7435mm2 157 133 110 110 9150mm2 196 167 137 13770mm2 242 206 169 16995mm2 293 249 205 205120mm2 339 288 237 237150mm2 389 331 272 272185mm2 444 377 311 311240mm2 522 444 365 365300mm2 601 511 421 421

N

For class 2 conductor cables

Ambient temperature +35°C +40°C +45°C +50°C +55°C +60°C +65°C +70°C +75°C +80°CCorrection factor 1,10 1,05 1,00 0,94 0,88 0,82 0,74 0,64 0,58 0,47

Size 1 2 3 4 5 7 10 12 14 16 19 24 27 37

Factor, n 1 0,85 0,7 0,7 0,58 0,52 0,46 0,44 0,41 0,40 0,37 0,35 0,33 0,301,0mm2 17 14 12 12 10 9 8 7 7 7 6 6 6 51,5mm2 22 19 15 15 13 11 10 10 9 9 8 8 7 72,5mm2 30 26 21 21 17 16 14 13 12 12 11 11 10 94mm2 39 33 27 27 236mm2 50 43 35 35 2910mm2 71 60 50 50 4116mm2 94 80 66 66 5525mm2 123 105 86 86 7135mm2 153 130 107 107 8950mm2 196 167 137 13770mm2 240 204 168 16895mm2 284 241 199 199120mm2 331 281 232 232150mm2 381 324 267 267185mm2 429 365 300 300240mm2 507 431 355 355300mm2 582 495 407 407

N

For class 5 conductor cables

Page 73: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

Formula 1:

S

tIk = 146 X

Based on formula:

S 234 + Tk

t 234 + TbIk = 226 X X In

73TECHNICAL INFORM

ATION1

/20

13

Ik = Maximum permissible short circuit current.S = Cross-section of the conductor in mm2.t = Duration of the short circuit in s.

Tk = Maximum rated conductor temperature,short circuit, °C

Tb = Maximum rated conductor temperature,normal, °C

Formula 1: For 0,6/1kV cable with XLPE or HF90 withmaximum operating temperature of +90°C (Tb) and short circuit temperature of +250°C (Tk).

Maximum permissible short circuit current.0,6/1 kV +90°C marine cables.

SHORT CIRCUIT CURRENT

Cross-section of Duration of the short circuit in s. the conductor in mm2 0,2 0,5 1 2 3 10

1,0 0,3 0,2 0,1 0,1 0,1 0,01,5 0,5 0,3 0,2 0,2 0,1 0,12,5 0,8 0,5 0,4 0,3 0,2 0,14 1,3 0,8 0,6 0,4 0,3 0,26 2,0 1,2 0,9 0,6 0,5 0,310 3,3 2,1 1,5 1,0 0,8 0,516 5,2 3,3 2,3 1,7 1,3 0,725 8,2 5,2 3,7 2,6 2,1 1,235 11,4 7,2 5,1 3,6 3,0 1,650 16,3 10,3 7,3 5,2 4,2 2,370 22,9 14,5 10,2 7,2 5,9 3,295 31,0 19,6 13,9 9,8 8,0 4,4120 39,2 24,8 17,5 12,4 10,1 5,5150 49,0 31,0 21,9 15,5 12,6 6,9185 60,4 38,2 27,0 19,1 15,6 8,5240 78,4 49,6 35,0 24,8 20,2 11,1300 97,9 61,9 43,8 31,0 25,3 13,9

Short circuit current in kA

SHORT CIRCUIT FACTOR

Short Circuit Factor can be calculated by following formula:

SHORT CIRCUIT FACTOR =SHORT CIRCUIT CURRENT

CURRENT RATING

Page 74: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

74TE

CHNI

CAL

INFO

RMAT

ION

1/2

01

3

Intermittent service

Correction factor for intermittent serviceaccording to the standard IEC 60092-352

The correction factor given hereby has beenroughly calculated for periods of 10 min,of which 4 min are with a constant load and6 min without load.

Intermittence period = 10min.Intermittence ratio = 40%.

1-exp(-10/T)

1-exp(-4/T)

Fi=

SHORT TIME DUTY

T = 0,245 x d 1,35

(d = Overall diameter of the cable, mm.)

Short time duty according to the standardIEC 60092-352 0,6/1 kV +90°Cmarine cables.

If a cable is intended to supply motoror equipment operating for periods of half an hour orone hour, its current rating given in table “currentrating”, may be increased using the relevantcorrection factors given by formula:

1,12

1-exp(-ts/T)

=correction

factor

( ts = service time, min. T = Time constant, min.)

Overall diameter of Correction the cable, mm. factor.

1 1,0002 1,0013 1,0124 1,0425 1,0836 1,1277 1,1708 1,2089 1,24210 1,27320 1,43330 1,49040 1,51850 1,53460 1,544

Overall Service Time Criticaldiameter of time, min. constant, duration,the cable, min. min.

mm.

30 60 T 3x T

1 1,058 1,058 0,245 0,7352 1,058 1,058 0,625 1,873 1,058 1,058 1,08 3,244 1,058 1,058 1,59 4,785 1,058 1,058 2,15 6,466 1,058 1,058 2,75 8,267 1,058 1,058 3,39 10,28 1,059 1,058 4,06 12,29 1,059 1,058 4,76 14,3

10 1,061 1,058 5,48 16,520 1,126 1,066 14,0 41,930 1,255 1,105 24,2 72,540 1,403 1,173 35,6 10750 1,554 1,254 48,2 14560 1,705 1,341 61,6 185

Correction factor.

Page 75: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

VOLTAGE DROP75

TECHNICAL INFORMATION

1/2

01

3

Cable types: LKM-HF, LKSM-HF, LKAM-HF, LKM-FRHF, LKSM-FRHF (Cables with class 2 conductor)

Size Resistance Resistance Voltage Resistance Current Voltageat +20°C at +90°C reduction at +45°C rating reductionohm/km ohm/km mV/Am *) ohm/km A **) mV/m ***)

1.0mm2 18,1 23,1 46,2 19,9 18 0,721.5mm2 12,1 15,4 30,9 13,3 23 0,612.5mm2 7,41 9,45 18,9 8,14 30 0,494mm2 4,61 5,88 11,8 5,06 40 0,416mm2 3,08 3,93 7,85 3,38 52 0,3510mm2 1,83 2,33 4,67 2,01 72 0,2916mm2 1,15 1,47 2,93 1,26 96 0,2425mm2 0,727 0,927 1,85 0,798 127 0,2035mm2 0,524 0,668 1,34 0,575 157 0,1850mm2 0,387 0,493 0,987 0,425 196 0,1770mm2 0,268 0,342 0,683 0,294 242 0,1495mm2 0,193 0,246 0,492 0,212 293 0,12120mm2 0,153 0,195 0,390 0,168 339 0,11150mm2 0,124 0,158 0,316 0,136 389 0,11185mm2 0,0991 0,1264 0,253 0,1088 444 0,097240mm2 0,0754 0,0961 0,192 0,0828 522 0,086300mm2 0,0601 0,0766 0,153 0,0660 601 0,079

Cable types: LKM-HF FLEX, LKSM-HF FLEX, LKEM-HF (Cables with class 5 conductor)

Size Resistance Resistance Voltage Resistance Current Voltageat +20°C at +90°C reduction at +45°C rating reductionohm/km ohm/km mV/Am *) ohm/km A **) mV/m ***)

0,75mm2 26,0 33,2 66,3 28,6 14 0,801.0mm2 19,5 24,9 49,7 21,4 17 0,731.5mm2 13,3 17,0 33,9 14,6 22 0,642.5mm2 7,98 10,18 20,4 8,76 30 0,534mm2 4,95 6,31 12,6 5,44 39 0,426mm2 3,30 4,21 8,42 3,62 50 0,3610mm2 1,91 2,44 4,87 2,10 71 0,3016mm2 1,21 1,54 3,09 1,33 94 0,2525mm2 0,78 0,995 1,99 0,857 123 0,2135mm2 0,554 0,706 1,41 0,608 153 0,1950mm2 0,386 0,492 0,984 0,424 196 0,1770mm2 0,272 0,347 0,694 0,299 240 0,1495mm2 0,206 0,263 0,525 0,226 284 0,13120mm2 0,161 0,205 0,411 0,177 331 0,12150mm2 0,129 0,164 0,329 0,142 381 0,11185mm2 0,106 0,135 0,270 0,116 429 0,10240mm2 0,0801 0,102 0,204 0,088 507 0,09300mm2 0,0641 0,082 0,163 0,070 582 0,08

Cable types: LKSM-HF 250V, RFE-HF, RFE-HF(i), RFA-HF, RFA-HF(i), RFE-FRHF, RFE-FRHF(i), RFA-FRHF, RFA-FRHF(i)

Size Resistance Maximum Resistance Voltage Resistance Voltageat +20°C conductor at +45°C reduction at +90°C reductionohm/km temperature, °C ohm/km mV/Am at +45°C ohm/km mV/Am at +90°C

0,5 mm2 40,4 90 44,4 88,7 51,5 103,00,75 mm2 26,0 90 28,6 57,1 33,2 66,31,5 mm2 12,8 90 14,1 28,1 16,3 32,6

*) at +90°C**) For continuous service (single core, ambient temperature +45°C)

***) at maximum current rating for continuous service at +45°C

Page 76: Marine Cables 1/2013 - Electech...2013/10/24  · 1/2013 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,5–10mm2 IEC 60228, class 2 - stranded

HELKAMA BICA OY

Lakimiehenkatu 4FI-20780 KAARINAFinland

Tel. +358 2 410 8700Fax +358 2 410 8750

[email protected]

[email protected]

Helkama Bica (Shanghai) Co., Ltd.

Plot 1-2, MinHang Export Processing ZoneNo. 3111 Huan Cheng West RoadFengxian District, Shanghai 201401,China

Tel. +86 21 3365 5333,Fax +86 21 3365 5331

[email protected]

www.helkamabica.fi

1/2013 Subject to change without prior notice. See latest updates on our webpage www.helkamabica.fi