19
March 31st and April 1st, 2009 Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger TURCK Inc.

March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Embed Size (px)

Citation preview

Page 1: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Fieldbus Physical Layer as an Asset

Randy Durick

Business Development Manger

TURCK Inc.

Page 2: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Plant Asset Management

Why Plant Asset Management?

Currently Plant Asset Management focuses on instrumentation performance

What about the infrastructure for the instrumentation?

Page 3: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Traditional Analog Circuits

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

4-20mA

Only 1 value is transmittedOnly one direction

Page 4: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Enabling Factors with FF

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

•Increased intelligence closer the process•online performance indication through process & device diagnostics•increased process stability

•Improvements•increasing plant availability•increasing productivity and product quality•less raw & waste material

•During longest lifecycle period of the plant: operation

Page 5: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Foundation fieldbus Capabilities

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

ST_REV, TAG_DESC, STRATEGY, ALERT_KEY, MODE_BLK, BLOCK_ERR, RS_STATE, TEST_RW, DD_RESOURCE, , MANUFAC_ID, DEV_TYPE, DEV_REV, DD_REV, GRANT_DENY,

HARD_TYPES, RESTART, FEATURES, FEATURE_SEL, CYCLE_TYPE, CYCLE_SEL, MIN_CYCLE_T, MEMORY_SIZE, NV_CYCLE_T, FREE_SPACE, FREE_TIME, SHED_RCAS,

SHED_ROUT, FAIL_SAFE, SET_FSAFE, CLR_FSAFE, MAX_NOTIFY, LIM_NOTIFY, CONFIRM_TIME, WRITE_LOCK, UPDATE_EVT, BLOCK_ALM, ALARM_SUM

ACK_OPTION, WRITE_PRI, WRITE_ALM

ST_REV, TAG_DESC, STRATEGY, ALERT_KEY, MODE_BLK, BLOCK_ERR, PV

OUT, SIMULATE, XD_SCALE, OUT_SCALE, GRANT_DENY, IO_OPTS, STATUS_OPTS, CHANNEL, L_TYPE, LOW_CUT, PV_FTIME, FIELD_VAL, UPDATE_EVT, BLOCK_ALM, ALARM_SUM, ACK_OPTION, ALARM_HYS,

HI_HI_PRI, HI_HI_LIM, HI_PRI, HI_LIM, LO_PRI, LO_LIM, LO_LO_PRI, LO_LO_LIM, HI_HI_ALM, HI_ALM, LO_ALM, LO_LO_ALM

ST_REV, TAG_DESC, STRATEGY, ALERT_KEY, MODE_BLK, BLOCK_ERR, PV, SP, OUT, PV_SCALE, OUT_SCALE, GRANT_DENY, CONTROL_OPTS, STATUS_OPTS, IN, PV_FTIME, BYPASS, CAS_IN, SP_RATE_DN, SP_RATE_UP, SP_HI_LIM, SP_LO_LIM

ST_REV, TAG_DESC, STRATEGY, ALERT_KEY, MODE_BLK, BLOCK_ERR, PVSP, OUT, PV_SCALE, OUT_SCALE, GRANT_DENY, CONTROL_OPTS, STATUS_OPTS,

INPV_FTIME, BYPASS, CAS_IN, SP_RATE_DN, SP_RATE_UP, SP_HI_LIM, SP_LO_LIM,

GAINRESET, BAL_TIME, RATE, BKCAL_IN, OUT_HI_LIM, OUT_LO_LIM, BKCAL_HYS,

BKCAL_OUT, RCAS_IN, ROUT_IN, SHED_OPT, RCAS_OUT, ROUT_OUT, TRK_SCALE, TRK_IN_D, TRK_VAL, FF_VAL, FF_SCALE, FF_GAIN, UPDATE_EVT, BLOCK_ALM, ALARM_SUM, ACK_OPTION, ALARM_HYS, HI_HI_PRI, HI_HI_LIM, HI_PRI, HI_LIM, LO_PRI, LO_LIM, LO_LO_PRI, LO_LO_LIM, DV_HI_PRI, DV_HI_LIM, DV_LO_PRI,

DV_LO_LIM, HI_HI_ALM, HI_ALM, LO_ALM, LO_LO_ALM, DV_HI_ALM. DV_LO_ALM

Page 6: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Field Device Asset Management

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Page 7: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

What About the Infrastructure?

Page 8: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Multi-barrier

EEx-e

Power Conditioner

EEx-i

Temperature ?

Voltage ?

Current ?

Jitter ? Noise ?

Ripple ?

Busload ?

Physical Layer Diagnostics

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Page 9: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Life Cycle of Fieldbus Physical Layer:Design

EnvironmentBus topologiesComponent selection

Commissioning“great view at the abyss”A new view to the physical layer “black

hole”Operation

ModificationExpansionsMaintenance

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Page 10: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Environment of the Fieldbus Infrastructure

Fieldbus Installations have to resist a lot of influences the drop of signal-quality of older field devices degrading of shielding, earthing and grounding noise & ripple, caused by other peripheral

devices, causing a drop of signal quality and interfere communication

negative effects of temperature, humidity, UV-light, vibrations

These are well known effects and their influence needs to be reduced by monitoring the fieldbus physical layer – no more “black hole”

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Page 11: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

EEx-e

Power Conditioner

EEx-i

MaintenanceHSE FD

∑ 4 Power Conditioner

Fieldbus Physical Layer Diagnostics

Multi-barrier

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Page 12: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Power Conditioner

HSE FD

∑ 4 Power Conditioner

Maintenance

Advanced Diagnostic Unit

EEx-e

EEx-i

Multi-barrier

Fieldbus Physical Layer Diagnostics

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Page 13: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Why HSE for the Diagnostics? Separate bus recieves diagnostic information regardless of DCS

Vender neutral protocol

Integration of Ethernet-based networks into FF-system architecture

FF-Function blocks

FF-Alarms

Ethernet – Accepted Physical Layer

Use of standard ethernet hardware

Virtually Unlimited number of stations are possible

Virtually Unlimited Ethernet Network length

High transmission speed of HSE

Page 14: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

What are the Online Diagnostics? Monitoring electrical values including alarming

voltage level bus power supply ambient temperature segment current load ripple noise jitter (each device) signal level at each device

Monitoring communication values address/ live list for devices on the segment

Communication statistics frame errors PDU (protocol data units) bus idle times cyclic – and acyclic communication

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Page 15: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Setpoints for Alarms (defaults)

HighHigh High

HighLow

HighHigh High

HighHigh High

HighHigh HighLowLow Low

LowLow Low

LowLow Low

LowLow Low

Temperature

Ripple

Noise

Jitter

Las Level

Device Level

Power Supply 1

Power Supply 2

Segment currentMarch 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Page 16: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Fieldbus Physical Layer as Asset 16

Page 17: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Fieldbus Physical Layer as Asset 17

Page 18: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

Fieldbus Physical Layer as Asset 18

Page 19: March 31st and April 1st, 2009Mile High Industrial and Automation Conference Fieldbus Physical Layer as an Asset Randy Durick Business Development Manger

March 31st and April 1st, 2009 Mile High Industrial and Automation Conference

Questions??