24
LT 2 Comp liance PREACHING TO THE CHOIR

Marc Chapman LT2 speechadem.alabama.gov/misc/swconf2016/MarcChapman-LT2Speech.pdfwith the plan submitted to the Department is a monitoring violation. ADEM Admin Code r 335‐7‐2‐.17(i)

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • LT2 CompliancepPREACHING  TO  THE  CHOIR

  • IntroductionIntroduction•Schedule •Schedule •Plans•Submission of Results

  • SchedulesSchedules• Schedule 1S t   ( i  • Schedule 1Systems  (serving 100,000 or more persons)

    •Schedule 2Systems  (serving 50,000 to 99 999 persons)to 99,999 persons)

    •Plans submitted and sampling started

  • SchedulesSchedules•Schedule 3 Systems  (serving •Schedule 3 Systems  (serving 49,999 to 10,000 persons)

    Pl   b itt d  d  li  •Plans submitted and sampling starts this month

  • SchedulesSchedulesUniversity of Alabama      VS         LSUUniversity of Alabama      VS.        LSU

    November 5th

  • SchedulesSchedules•Schedule 4 Systems  (serving less •Schedule 4 Systems  (serving less than 10,000 person)

    •Plans must be submitted by June 30  201730, 2017

    •Sampling commences in Oct 2017

  • SchedulesSchedulesAuburn University          VS               GeorgiaAuburn University          VS.              Georgia

    November 12th

  • PlansPlans•Schematic of where sample is to •Schematic of where sample is to be taken

    •Sample schedule that specifies the date of collection date of collection 

  • Simple Hand Drawings are Acceptable

  • Abstract Art is Not Acceptable

  • Submission of ResultsSubmission of Results•PWS‐ID•PWS‐ID•Facility IDy•Collection Date•Sample Type (field or matrix spike)

  • Submission of ResultsSubmission of Results

    •The number of oocystsThe number of oocysts

  • Submission of ResultsSubmission of Results

    •Bin CalculationsBin Calculations

  • Submission of ResultsSubmission of Results•If the system took 48 or more •If the system took 48 or more samples:

    U  th     f th   l  Use the average of the sample results

  • Submission of ResultsSubmission of Results•If the system took 24 samples:•If the system took 24 samples:

    Use the average of the sample ltresults

  • Submission of ResultsSubmission of Results•If the system took between 24 to •If the system took between 24 to 47 samples:

    th  hi h t    f  ll  l  the highest average of all samples in any 12 month period 

  • OOcysts / L Bin Classification Additional Treatment ConventionalFiltration

    Additional TreatemtnDirect Filtration

  • Submission of ResultsSubmission of Results•Additional Treatment•Additional Treatment

  • Submission of ResultsSubmission of Results•Additional Treatment•Additional Treatment

  • Submission of ResultsSubmission of ResultsUV DisinfectionUV Disinfection

  • Submission of ResultsSubmission of ResultsO iOzonation

  • Submission of ResultsSubmission of Results• If you have a few high sample results  you may • If you have a few high sample results  you may sample more frequently if the sampling is evenly spaced throughout the monitoring y p g gperiod.

    ADEM Admin Code r 335‐7‐2‐.17(c)  

  • Submission of ResultsSubmission of Results• If you have a few high sample results  you may • If you have a few high sample results  you may not halt sampling.

    •Failure to collect any sample in accordance •Failure to collect any sample in accordance with the plan submitted to the Department is a monitoring violation.a monitoring violation.

    ADEM Admin Code r 335‐7‐2‐.17(i)  