HUAWEI Parameters Sie BSC Version: G3BSC32.10100.06.1120A Siemens Table Parameter Range Unit Default Remark Parameter Local-office BSC Cell Table Cell System Type GSM900/GSM1800 GSM900 SYSID BCC 0~7 - OCT BCC NCC 0~7 - OCT NCC CGI - HEX CELLGLID Support GPRS Yes / No Yes GSUP Frequency Hopping Table HSN 0~63 - HSN TSC 0~7 same as BCC TSC Radio Channel Config. Table CH Type CHTYPE MAIO 0~(N-1) - MAIO MAIO I N D O S A T same as BCC Tch full rate/Tch half rate 01/Tch half rate 0/SDCCH8/Main BCCH/Combined BCCH/BCH/BCCH+CB CH/PBCCH+PDTCH/P CCCH+PDTCH/PDTCH /Dynamic PDTCH 1or2TRX: 1SDCCH/8; 3or4TRX: 2SDCCH/8; 5or6TRX: 3SDCCH/8. And SD dynamic allocation allowed must be Yes

Mapping Parameter From Siemens to Huawei

  • Upload
    tri-ary

  • View
    162

  • Download
    7

Embed Size (px)

Citation preview

Page 1: Mapping Parameter From Siemens to Huawei

HUAWEI Parameters Siemens ParametersBSC Version: G3BSC32.10100.06.1120A Siemens

Table Parameter Range Unit Default Remark Parameter current setting

Local-office

BSC Cell Table

Cell System Type GSM900/GSM1800 GSM900 SYSID BB900/DCS1800

BCC 0~7 - OCT BCC

NCC 0~7 - OCT NCC

CGI - HEX CELLGLID

Support GPRS Yes / No Yes GSUP

Frequency Hopping Table

HSN 0~63 - HSN

TSC 0~7 same as BCC TSC

Radio Channel Config. Table

CH Type CHTYPE

MAIO 0~(N-1) - MAIO MAIO

INDOSAT

same as BCC

Tch full rate/Tch half rate 01/Tch half rate 0/SDCCH8/Main BCCH/Combined BCCH/BCH/BCCH+CBCH/PBCCH+PDTCH/PCCCH+PDTCH/PDTCH/Dynamic PDTCH

1or2TRX: 1SDCCH/8; 3or4TRX: 2SDCCH/8; 5or6TRX: 3SDCCH/8. And SD dynamic allocation allowed must be Yes

Page 2: Mapping Parameter From Siemens to Huawei

Site

Carrier Configuration Table

Static TRX Power Class grade 0 PWRRED 0

Carrier Power Type 40W/60W/Default Default

HW-IUO Property None CONCELL

TRX Priority 0~7 0

Cell

System Information Table

System Information

Regular Transmission Yes / No Yes

Regular Transmission Interval 0~255 min. 10

MS MAX Retrans 1,2,4,7 times 4 MAXRETR 1,4

Common Access Control Class ACC

Special Access Control Classl 0 0 0 0 0 ACC

0~6(BTS30,0407 Version), 0~10 (0529 Version), 0~13 (microcell)

0 is full power, step is -2dBm

OverLaid Cell /UnderLaid / None

Sys information 1~6, 2bis, 2ter, 5bis, 5ter

0 1111000000111111

Sys information 1~6,2bis,2ter,5bis,5ter

this parameter set more biger , and Call setup successful rate is more higher , but the load of RACHand SDCCH is also heavier.

Level 1/ 2/ 3/ 4/ 5/ 6/ 7/ 8/ 9/ 10 Forbidden

0 0 0 0 0 0 0 0 0 0

Level 11/ 12/ 13/ 14/ 15 Forbidden

Page 3: Mapping Parameter From Siemens to Huawei

Cell Channel Description Format

ATT Yes / No Yes IMSIATDT 1

PWRC Yes / No Yes 1

UL DTX DTXUL SHLFSHNH

Tx- integer 4.615mS 32 NSLOTST 9,14

CBA Yes / No Yes CB 1

EC Allowed Yes / No Yes EC 1

Call re-establishment allowed Yes / No no CREALL NOTALLOWED

NCC Permitted 11111111 PLMNP

BS_AG_BLKS_RES block 2 NBLKACGR 1

CCCH_CONF

BA_PA_MFRAMS 2 NFRAMEPG 2

T3212 6min. 15 T3212 40,20

Radio Link Timeout 4~64 480ms 52 RDLNKTO 4,3,5,7

1024,512,256,128,bitmap

bitmap(100000)

EBSPWRC / EMSPWRCAllowed/

Mandatory/Forbidden

3~12,14,16,20,25,32,50

20, 32(satellite transmission)

CELL BAR ACCESS

EC=Emergency call

0~2 (one combined

CCCH), 0~7(others)

1(combined), 2(no-combined)

one no-combined CCCH/ one combined CCCH/ two no-combined CCCHs/ three no-combined CCCHs/ four no-combined CCCHs

non-combined CCCH

fit in with the quantity of TRX in the cell

2-9 CCCH multiframes

0~255

20~30(urban), 10~20(suburban) 8~10(mountain)

step=4, period of SACCH=480ms

I34
gciuser: SHLFSHNH (MS shall use DTX for FR TCHs, shall not for HR TCHs).
I35
Tong Jiangping: 9->12 14->32 most of cells is 14
Page 4: Mapping Parameter From Siemens to Huawei

MS_ TXPWR_MAX_CCH grade 5 0(1800),5(900) MSTXPWRMX 0,5

RXLEV_ACCESS_MIN 0~63 grade 8 RXLEVAMI 8,10

ACS Yes / No No

Half Rate Supported Yes / No No EHRACT FALSE/true

CRH 0~14 dBm 4 CELLRESH

CBCH CH Description 6BIT 0 SMSCBUSE

CBCH Mobile Allocation 0 SMSCBUSE

PI Yes / No Yes CRESPARI 1

CBQ Yes / No No Cell Bar Qualify CBQ 0,1

CRO 0~63 0 CRESOFF

TO 0~7 0 TEMPOFF

PT 0~31 0 PENTIME

ECSC Yes / No No EARCLM

Power Deviation Indication Yes / No YES

Power Deviation 0/1/2/3 1 0, 2, 4, 6dBm PWROFS

0~20

grade-110=dBM, 8 means -102dBm

Cell reselection hysteresis, step=2;4(normal), 8~10 (urban) 3,4

only use in cell broadcast operatting

only use in cell broadcast operattingCell Reselect Parameters IndicationCell Reselect Offset, step=2dB, 0~63 means 0~126dB

Cell Reselect Temporary Offset, 0~6 is 0~60 dB, 7 is

Cell Reselect Penalty Time, 0~30 is 20~620ms, when PT=31, C2=C1-CRO

TRUE,false

B46
Tong Jiangping: 6
B48
Tong Jiangping: 看是否有扩容,如果扩容则改为全速率
Page 5: Mapping Parameter From Siemens to Huawei

MBR 0~3 0 NMULBAC

Cell Configuration Table

Data Service Allowed 0110111000 SPEED145

Encryption Algorithm 10000000 ENCALSUP

FH Mode Not Hopping fit in with fact HOPMODE BBHOP/SYNHOP

SMCBC DRX Yes / No No SMSCBUSE

DL DTX Yes / No No 1

TRX iding function control

Cell Allocation Table

ARFCN 0 - CALLF01

… ….

ARFCN 63 - CALLF63

BA1(BCCH) Table

BCCH of NCell 1 -

BCCH of NCell 32 -

0(single~band), 2~3 (dual~band) 0,3

NT 12K FULL RATE, NT 12K HALF RATE, NT 12K, NT 6K, T 9.6K, T 4.8K, T 2.4K, T 1.2K, T 600 BITS, T 1200/75

Not support,A5/1~A5/7

NOENCR&GSMV1

Not hopping/ Baseband hopping/ Radio frequency hopping

No, Yes(cell broadcast)

DTXDLFR / DTXDLHR

Not switchover, Switchover promptly, Switchover when ckeck resource

Allowed, recover when check res.

Page 6: Mapping Parameter From Siemens to Huawei

BA2(SACCH) Table

BCCH of NCell 0 -

BCCH of NCell 32 -

Cell Attribute Table

Interf. Band Thrsh. 0 110 -dBm 110 INTAVEPR

Interf. Band Thrsh. 1 110~85 -dBm 105 INTAVEPR#1

Interf. Band Thrsh. 2 110~85 -dBm 98 INTAVEPR#2

Interf. Band Thrsh. 3 110~85 -dBm 90 INTAVEPR#3

Interf. Band Thrsh. 4 110~85 -dBm 87 INTAVEPR#4

Interf. Band Thrsh. 5 85 -dBm 85 INTAVEPR#5

Interf. Calculation Period 1~31 480ms 20 INTAVEPR 8-4-8-14-20

SACCH Multi_Frames 0~255 480ms 31 RDLNKTBS 16,20,24,32

Radio Resource Report Period 0~255 s 10 RADIOMG

CCCH Load Indication Period 0~255 s 15 PCCCHLDI 255

CCCH Load Thrsh. 0~100 % 100 TCCCHLDI 100

Max Resend Times of Phy. Info. 1~255 times 100 NY1 100,only 3 sites 40

OverLoad Indication Period 0~255 s 15 LAPDOVLT

RACH Busy Thrsh. 0~63 grade 16 RACHBT

Average RACH load TS number 0~65535 timeslot 5000 RACHLAS

Max RC Power Reduction 0~255 step=2dB 5 PWRREDSS DB2

T200 SDCCH(5ms) 50~100 5ms 60 T200

T200 FACCH/F 40~100 5ms 50 T200

T200 FACCH/H 40~100 5ms 50 T200

period of SACCH=480ms

period of SACCH=480ms

grade-110= dBm; 5(BTS20,BTS22C),16(BTS3X)

Page 7: Mapping Parameter From Siemens to Huawei

T200 SACCH TCH SAPI0 120~200 10ms 150 T200

T200 SACCH TCH SAPI3 120~200 10ms 200 T200

T200 SACCH SDCCH 50~100 10ms 60 T200

T200 SDCCH SAPI3 50~100 10ms 60 T200

T3105 0~255 10ms 7 T3105 ms10-4,2,8,10

MAX TA 0~127 550m 63 EXCDIST 0

Frame start time No Use

Paging Times 1~8 times 3 msc paging

Random Access Error Thrsh. 0~255 180

Power Class 5 No Use PWRRED 0

RACH Min. Access Level 0~63 grade 5 grade-110= dBm

DC bias voltage Thrsh. BTS3X No Use

Cell Extension Type normal CELLTYPE STDCELL

Cell Extension Offset 0~35 km 0 HOMSTAM 32

Diversity LNA bypass permitted Yes 3002C

Cell Call Control Table

TCH Immediate Assignment Yes / No No

Immediate Assignment Opt. Yes / No No

Immediate Assign to Other Cell Yes / No No

Assign to Other Cell Yes / No Yes

62(Normal cell), 63(Single timeslot extended cell), 219(Double timeslot extended cell)

Normal cell,Single timeslot extended cell,Double timeslot extended cell

B109
Tong Jiangping: DCS is 0 GSM900 is 5
B117
Tong Jiangping: VSAT site -> Yes
Page 8: Mapping Parameter From Siemens to Huawei

TCH Assignment Retry Yes / No No

Short message uplink disabled Yes / No No

Short message downlink disabled Yes / No No

OM start intra-cell HO Yes / No Yes No Use

OM start inter-cell HO(intraBSC) Yes / No Yes No Use

OM start inter-BSC HO Yes / No Yes No Use

TCH flow alarm Yes / No No

RF CH abnormal release retry Yes / No Yes No Use

Abis flow control permitted Yes / No No

Abis flow control permitted No

Direct Retry Yes / No Yes ENFORCHO ENABLE

Cell Call Control Para. Table

T3101(100ms) 3~50 100ms 30 t3101 HLFSEC-6

Assign-TCH idle rate Thrsh. 0~100 % 80 No Use SDCCHCONGTH

Assign-TCH re-Estb. rate thrsh. 0~100 % 80 SDCCHCONGTH

TCH Flow Control Start Thrsh. 0~7 timeslot 2

Max Assignment Retry Times 0~3 times 2

Ilde TCH Thrsh. for SD to TCH HO 0~100 % 80

Max. radioCH release retry times 0~3 times 1 No Use

Select circuit pool function,Deselect circuit pool function,Dystem auto~select

70,80,85,100

70,80,85,100

Page 9: Mapping Parameter From Siemens to Huawei

Service Type Req.(SD to TCH HO) No Use ENFORCHO ENABLE

Out HO Request Resend Interval 0~15 s 10 No Use BSCTQHO HLFSEC-120

Out BSC HO Req. Resent Times 0~3 times 2 No Use

Syst. Delay Frame No.Adjust number 0

Response On Out BSC HO Req. Yes / No Yes INTERCH 1

Handover

Handover Control Data Table

HO Algorithm HUAWEI No

Min Interval for TCH HOs 1~60 s 6 No

Min Interval for SD HOs 1~60 s 2 No

Min Interval for Consecutive HOs 1~60 s 6 THORQST

Min Interval for Urgent HOs 1~60 s 6 No

Co-BSC/MSC Adj. Yes / No No No

SD HO Allowed Yes / No no IERCHOSDCCH 0

Penalty Allowed Yes / No yes

IntraCell HO Allowed Yes / No Yes INTRACH 1

Load HO Allowed Yes / No NO TRFHOE 0

MS fast moving HO allowed Yes / No no

Rx_Level_Drop HO Allowed Yes / No no EFULHO 0

PBGT HO Allowed Yes / No Yes PBGTHO 1

MSC service request,Location update request,Paging response,MSC service re~establish request,Unknow

MSC service request

HUAWEI / GSM0508

10,12,14,15,16

Page 10: Mapping Parameter From Siemens to Huawei

MS Power Prediction after HO Yes / No no No

MR. Preprocessing Yes / No No No, Yes(15:1) No

Transfer Original MR. Yes / No No No

Transfer BS/MS power class Yes / No Yes No

Sent Freq.of Preprocessed MR. No

Mmnc HO allowed No

Mmnc HO type No

Cell Description Data Table

BCCH BCCH_FREQ

CGI HEX 510-01-LAC-CI

NCC 0~7 OCT NCC NCC-BCC

BCC 0~7 OCT BCC NCC-BCC

Layer of Cell Layer 3 No

Cell Priority No

Cell Type normal cell/IUOcell normal cell CELL_TYPE STDCELL

Inter-layer HO Thrsh. 0~63 grade 25 grade-110= dBm No

Inter-layer HO hysteresis 0~63 dB 3 No

Penalty on MS Fast Moving HO 0~63 s 30 No

Penalty Time on Fast Moving HO 0~255 s 40 No

Min DL Level on Candidate Cell 0~63 grade 15 grade-110= dBm RXLEVMIN 12

Not up report,Twice per second,Once per second,Once every 2s,Once every 4s

Twice per second

Twice per second, Once per second(15:1)

MCC-MNC-LAC-CI

Layer 1,Layer 2,Layer 3,Layer 4

PICO, MICRO, MACRO, UMBRELLA

priority level 1~priority level 16

priority level 1

B171
Tong Jiangping: 先
Page 11: Mapping Parameter From Siemens to Huawei

UL Expected Level at HO Access 0~63 grade 35 grade-110= dBm No

External Cell Description Table

BCCH BCCH_FREQ BCCHFREQ

CGI HEX 510-01-LAC-CI

NCC 0~7 OCT NCC NCC-BCC

BCC 0~7 OCT BCC NCC-BCC

Co-MSC Yes / No No

Layer of the Cell Layer 3 No

Cell Priority No

Inter-Layer HO Thrsh 0~63 grade 25 grade-110= dBm No

Inter-Layer HO Hysteresis 0~63 s 3 No

Penalty on Fast Moving HO 0~63 grade 30 grade-110= dBm No

Penalty Time on Fast Moving HO 0~255 s 40 No

Min DL Level on Candidate Cell 0~63 grade 15 grade-110= dBm RXLEVMIN 12Adjacent Cell Relation Table

PBGT HO Thrsh. 0~127 68 HOM 69

Inter-Cell HO Hysteresis 0~63 4 No

Min Access Level Offset 0~63 0 NoFilter Table

Allowed M.R number lost 0~32 MR 4 No

Filter Length for TCH Level 1~32 s 6 No

MCC&MNC&LAC&CI

Layer 1,Layer 2,Layer 3,Layer 4

PICO, MICRO, MACRO, UMBRELLA

priority level 1~priority level 16

priority level 1

68(urban),72(suburban)

4(urban),8(suburban)

Page 12: Mapping Parameter From Siemens to Huawei

Filter Length for TCH Qual. 1~32 s 6 No

Filter Length for SD Level 1~32 s 3 No

Filter Length for SD Qual. 1~32 3 No

Filter Length for NCell RX_LEV 1~32 6 No

Filter Length for TA 1~32 6 No

Panalty Table

Penalty level after HO Fail. 0~63 grade 30 No

Penalty time after HO Fail. 0~60 s 10 No

Penalty level after BQ HO 0~63 grade 63 No

Penalty time after BQ HO 0~60 s 10 No

Penalty level after TA HO 0~63 grade 63 No

Penalty time after TA HO 0~60 s 10 No

Penalty time after IUO HO Fail. 0~16 s 10 No

Emergency Handover Table

TA Thrsh. 0~63 62 35 , 100

DL Qual. Thrsh. 0~70 60 RQ*10 HOLTHQUDL

UL Qual. Thrsh. 0~70 60 RQ*10 HOLTHQUUL

UL Qual. Thrsh. for Interf.HO 0~70 50 RQ*10 No

DL Qual. Thrsh. for Interf.HO 0~70 50 RQ*10 No

63(normal cell), 219 (Double timeslot extended cell)

HOTMSRM&HOTMSRME

4,5,6,7

4,5,6,7

Page 13: Mapping Parameter From Siemens to Huawei

UL RX_LEV Thrsh. for Interf.HO 0~63 grade 25 grade-110= dBm HOTULINT 35

DL RX_LEV Thrsh. for Interf.HO 0~63 grade 30 grade-110= dBm HOTDLINT

Uplink level SHTM filter length 0~20 3 No

Filter Parameter A1 0~20 10 No

Filter Parameter A2 0~20 10 No

Filter Parameter A3 0~20 10 No

Filter Parameter A4 0~20 10 No

Filter Parameter A5 0~20 10 No

Filter Parameter A6 0~20 10 No

Filter Parameter A7 0~20 10 No

Filter Parameter A8 0~20 10 No

Filter Parameter B 0~255 0 No

MIN TA 0~63 0 No

Load Handover Table

System Flux Thrsh. for Load HO 0,8~11 10 No

Load HO Thrsh. 0~7 load grad 5 TRFHITH 90

Load Req. on Candidate Cell 0~7 load grad 2 No

Load HO Bandwidth 0~63 grade 25 grade-110= dBm No

30,35,40,63

system flux grade

Page 14: Mapping Parameter From Siemens to Huawei

Load HO Step Period 1~60 s 10 No

Load HO Step Level 1~63 grade 5 grade-110= dBm No

Normal Handover Data Table

Edge HO UL RX_LEV Thrsh. 0~63 grade 15 No

Edge HO DL RX_LEV Thrsh. 0~63 grade 20 No

Edge HO Watch Time 1~16 s 5 No

Edge HO Valid Time 1~16 s 4 No

Layer HO Watch Time 1~16 s 5 No

Layer HO Valid Time 1~16 s 4 No

PBGT Watch Time 1~16 s 5 No

PBGT Valid Time 1~16 s 4 No

MS Fast Moving HO Data Table

MS Fast-Moving Watch Cells 1~10 cell 3 No

MS Fast-Moving Valid Cells 1~10 cell 2 No

MS Fast-Moving Time Thrsh. 0~255 s 15 No

Intra-cell cont. HO ctrl. table

MAX Consecutive HO Times 1~20 times 3 No

grade-110= dBm;25(no PBGT, urban), 20 (single BTS, suburban; PBGT, urban)

grade-110= dBm;25(no PBGT, urban), 20 (single BTS, suburban; PBGT, urban)

Page 15: Mapping Parameter From Siemens to Huawei

Forbidden Time after MAX Times 1~200 s 20 No

Interval for Consecutive HO Jud. 1~200 s 6 No

GSM0508 handover table No Use

HW~IUO Handover Table HW~IUO

UL to OL HO allowed

OL to UL HO allowed

RX_LEV for UO HO allowed

RX_QUAL for UO HO allowed

TA for UO HO allowed CCDIST 0

UO signal intensity difference

RX_LEV Thrsh. 0~63 grade 25

RX_LEV Hysteresis 0~63 dB 3

RX_QUAL Thrsh.

TA Thrsh. 0~63 550m

TA Hysteresis 0~63 550m

UO HO Watch Time 0~16 s 5

UO HO Valid Time 0~16 s 4

Assign Optimum Layer

>Edge HO DL RX_LEV Thrsh.+UO signal intensity difference

System optimization/OverLaid subcell/UnderLaid subcell/No preferential

System optimization

Page 16: Mapping Parameter From Siemens to Huawei

Assign-Optimum-Level Thrsh. 0~63 dBm

pref. subCell in HO of Intra_BSC Y/N

pref. subcell in HO of intra-BSC

Incoming-to-BSC HO optimum layer

Power

Power Control Selection Table

PC Algorithm HW_2

UL PC Allowed Yes / No Yes

DL PC Allowed Yes / No Yes

Ordinary Cell PC Table No Use

BTS Power Control Table HW I

BTS PC Period 1~10 480ms 5

DL RX_LEV Expected 0~63 grade 35

Filter Length for DL RX_LEV 1~31 none 5 grade-110= dBm

DL RX_LEV Compensation 0~100 % 80

DL Qual. Expected 0~7 grade 1

Filter Length for DL Qual. 1~31 none 5

DL Qual. Compensation 0~100 % 20

BTS Min Tx Power 0~10 dBm 4

MAX PC Step 1~15 grade 8

BTS Max Tx Power 30~58 dbm 46 step=2dB

UnderLaid subcell

OverLaid subcell/UnderLaid subcell/No preferential

UnderLaid subcell

GSM_0508 / HW_1 / HW_2

HW_2, HW1(BTS22C)

period of SACCH=480ms

E279
Turn Off the UL PC of some cell
E280
Turn off all the Dl Power Control
Page 17: Mapping Parameter From Siemens to Huawei

PC Adj. Range grade 16

MS Power Control Data Table HW I

PC Interval 1~16 480ms 5

Initial RX_LEV Expected 0~63 grade 30

Filter Length for Initial RX_LEV 1~31 none 2 grade-110= dBm

Stable RX_LEV Expected 0~63 grade 30

Filter Length for Stable RX_LEV 1~31 none 5 grade-110= dBm

UL RX_LEV Compensation 0~100 % 80

UL Qual. Expected 0~7 grade 1

Filter Length for Qual. 1~31 none 6

UL Qual. Compensation 0~100 % 20

Power Increment after HO Fail. 0~4 grade 2

MAX PC Step 1~15 grade 8 step=2dB

HWII Power Control Data Table HW II

PC Interval 1~15 480ms 5

Filter Length for UL RX_LEV 1~20 MR 6

Filter Length for DL RX_LEV 1~20 MR 6

Filter Length for UL Qual. 1~20 MR 6

Filter Length for DL Qual. 1~20 MR 6

MR. Compensation Allowed Yes / No Yes

1~16. corresponding to 0dB~30dB

46(macro cell), 36(BTS22C), 39(BTS3001C)

period of SACCH=480ms

period of SACCH=480ms

period of SACCH=480ms

Page 18: Mapping Parameter From Siemens to Huawei

UL MR. Number Predicted 0~3 MR 2

DL MR. Number Predicted 0~3 MR 2

UL RX_LEV Upper Thrsh. 0~63 grade 40

UL RX_LEV Lower Thrsh. 0~63 grade 30 grade-110= dBm

UL Qual. Upper Thrsh. 0~7 grade 0 grade-110= dBm

UL Qual. Lower Thrsh. 0~7 grade 2

DL RX_LEV Upper Thrsh. 0~63 grade 40

DL RX_LEV Lower Thrsh. 0~63 grade 30 grade-110= dBm

DL Qual. Upper Thrsh. 0~7 grade 0 grade-110= dBm

DL Qual. Lower Thrsh. 0~7 grade 2

MAX Adj. Value for Qual. Zone 0 0~30 dB 4

MAX Adj. Value for Qual. Zone 1 0~30 dB 4

MAX Adj. Value for Qual. Zone 2 0~30 dB 4

Adj. PC Value by RxQual. 0~4 dB 4

UL Qual. bad TrigThrsh 5

UL Qual. bad UpLEVDiff 0

DL Qual. bad TrigThrsh 5

DL Qual. bad UpLEVDiff 0

BTS Max. Power 30~58 dBm 48

BTS PC class 1~16 2dB 16

Channel

Radio CH management ctrl. Table

CH Allocation Algorithm HW-1/HW-2Huawei II algorithm

Page 19: Mapping Parameter From Siemens to Huawei

SD dynamic allocation allowed

Idle SD Thrsh. 2

Cell SD maximum 80

TCH minimum recovery time(s) 600

Idle TCH Thrsh. N1 0

Apply-TCH decision period T(m) 0

IDLE Thrsh. for TCH/F priority 2

TCH rate adjust allowed

TCH rate adjust traffic Thrsh. 80

MIN recovery time of TCH/H 600

HWII Channel Allocation Table HW II

SD Allocation Priority Allowed Y/N

Interf. Priority Allowed Y/N Y

Active CH Interf. Meas.Allowed Y/N Y

Allocation TRX Priority Allowed Y/N Y

History Record Priority Allowed Y/N Y

Balance Traffic Allowed Y/N Y

Interf. of UL Level Thrsh. 0~63 grade 31

Interf. of UL Qual. Thrsh. 0~70 grade 40 grade-110= dBm

Interf. of DL Level Thrsh. 0~63 grade 31 RQ*10

Interf. of DL Qual. Thrsh. 0~70 grade 40 grade-110= dBm

Filter Length for TCH Level 1~32 6 RQ*10

Filter Length for TCHQual. 1~32 6

Yes

No

No

Page 20: Mapping Parameter From Siemens to Huawei

Filter Length for SDCCH Level 1~32 2

Filter Length for SDCCH Qual. 1~32 2

Updata Period of CH Record 1~1440 min. 30

Updata Freq. of CH Record 1~32 2

Page 21: Mapping Parameter From Siemens to Huawei

Siemens ParametersSiemens

Default Unit Same/Not Question

same

same

same

same

same

same

same

same

Page 22: Mapping Parameter From Siemens to Huawei

same

Huawei special

not

Huawei special

Huawei Special

Huawei Special

Huawei Special

4 same

not

not

Page 23: Mapping Parameter From Siemens to Huawei

Huawei Special

same

same

same

10 same

same

same

same

255 same

same

Huawei Special

same

10 same

4 same

J44
gciuser: S0 = 4 + 4 RDLNKTO
Page 24: Mapping Parameter From Siemens to Huawei

same

6 same

Huawei Special

same

same

not

not

same

same

0 same

0 same

0 same

1 same

Huawei Special

0 same

MSTXPMAX_GSM/MSTXPMAX_DCS

Page 25: Mapping Parameter From Siemens to Huawei

0 same

not

same

BBHOP same

not

same

Huawei Special

same

same

same

Huawei Special

Huawei Special

Huawei Special

J63
gciuser: GSMV1 represents the ciphering algorithm A5/1,
Page 26: Mapping Parameter From Siemens to Huawei

Huawei Special

Huawei Special

Huawei Special

same

same

same

same 现网

same

same

20 same

not

same

same

same

not

not

not

same

same

same

same

Page 27: Mapping Parameter From Siemens to Huawei

same

same

same

same

MS10-4 same

1 same

Huawei Special

Huawei Special

Huawei Special

not

6 same

HuaWei special

STDCELL same

not

Huawei Special

Huawei Special

Huawei Special

Huawei Special

Huawei Special

J104
gciuser: MS10 = 10ms
Page 28: Mapping Parameter From Siemens to Huawei

Huawei Special

Huawei Special

Huawei Special

Huawei Special

Huawei Special

Huawei Special

Huawei Special

Huawei Special

Huawei Special

Huawei Special

ENABLE same

same

not

not

Huawei Special

Huawei Special

not

Huawei Special

Page 29: Mapping Parameter From Siemens to Huawei

not

not

Huawei Special

Huawei Special

not

5

0 For inter-cell HO

1

0

0

1

2 SACCH multiframes

Page 30: Mapping Parameter From Siemens to Huawei

Same OCT

Same OCT

12 1dB

Page 31: Mapping Parameter From Siemens to Huawei

12 1dB

69 1dB

0 = -63dB126 = +63dB69 (= 6dB)

Page 32: Mapping Parameter From Siemens to Huawei

1km Not

5

5

34&99

HOTMSRM for normal cell&HOTMSRME for extended cell

Page 33: Mapping Parameter From Siemens to Huawei

35 1dB

35 1dB

90 1%

Handover Threshold (dBm) = -110dBm + HOTULINT

Handover Threshold (dBm) = -110dBm + HOTDLINT

Page 34: Mapping Parameter From Siemens to Huawei
Page 35: Mapping Parameter From Siemens to Huawei

No Use

HW~IUO

0

Page 36: Mapping Parameter From Siemens to Huawei

No Use

HW I

Page 37: Mapping Parameter From Siemens to Huawei

HW I

HW II

Page 38: Mapping Parameter From Siemens to Huawei
Page 39: Mapping Parameter From Siemens to Huawei

HW II

Page 40: Mapping Parameter From Siemens to Huawei