Upload
others
View
6
Download
0
Embed Size (px)
Citation preview
Many options, one source
Capnography
Supplies
452299160511.indd 1452299160511.indd 1 03/12/2020 10:5103/12/2020 10:51
This printed copy is not an official Philips hard copy, use for reference only
2
Accurate measurements and clinical versatility With Philips, you can choose a single capnography monitoring technology to meet different patient needs at different times. Capnostat 5 mainstream and LoFlo sidestream etCO2 sensors use a common extension server, providing clinical versatility to use either solution with the same monitor.
Why capnography? Capnography monitoring provides informationneeded to prompt intervention for patients with conditions which may lead to hypoxia if uncorrected. Why Philips? Philips versatile CO2nnect & Go mainstream and sidestream capnography solutions support clinical workflow throughout the hospital environment. From neonates to adults, we bring our technology across the continuum of care: surgical suite, intensive care unit, emergency room, general ward, procedural sedation – two clinical options, one common connection. With Philips as a trusted supply partner, you can be confident in quality consumables that are validated for both Philips and non-Philips devices, built to high standards of durability.
452299160511.indd 2452299160511.indd 2 03/12/2020 10:5103/12/2020 10:51
This printed copy is not an official Philips hard copy, use for reference only
3
Sidestream monitoring is a good option for non-intubated, spontaneously breathing patients as well as patients requiring intubation during short-term procedural sedation or anesthesia.
Our diverse LoFlo sidestream portfolio includes airway adapters and oral/nasal patient interfaces (with or without O2 delivery and dehumidification options), allowing for ventilation monitoring across the clinical workflow, and from neonates to adults.
The 50 ml/minute sampling rate makes them highly suitable for use with infant and neonatal patients.
Sidestream monitoringMainstream monitoring is an ideal choice for intubated patients. It provides a non-diverting, crisp, accurate CO2 waveform with no time delay, and does not require use of a scavenger system to collect anesthesia gases. Because patient secretions or high humidity do not contaminate the sensor, it is a preferred choice for intubated patients.
The small, rugged, lightweight Capnostat 5 sensors offer fast, accurate on-airway measurement for intubated patients. The light weight makes them a comfortable option for even your smallest patients. They can be used with either single-patient use (SPU) airway adapters or reusable airway adapters that are designed for long-term use and color-coded for easy identification.
Mainstream monitoring
452299160511.indd 3452299160511.indd 3 03/12/2020 10:5103/12/2020 10:51
This printed copy is not an official Philips hard copy, use for reference only
4
Procedural sedation, pain management
Airway management, resuscitation,
transport
Intubated
Mainstream single-patient use airway adapters
Mainstream reusable
airway adapters
Sidestream long-termairway adapters with
humidity management
M2533A M2513A
M2536A M2516A
Ad
ult
Pe
dia
tric
Infa
nt/
Ne
on
ata
l
M2772A Airway adapter set H
(ET tube >4.0 mm)
Choose the right accessories for your patient needs
M2773A Airway adapter set H(ET Tube +/-4.0 mm)
989803144531 Airway adapter set
(ET tube +/-4.0 mm)
M2772A Airway adapter set H
(ET tube >4.0 mm)
M2513A
Sidestreamshort-term
airway adapters
M2768A Airway adapter set(ET tube >4.0 mm)
M2768A Airway Adapter set(ET tube >4.0 mm)
M2533A
Mainstream
Sidestream
Ventilator, ventilation
management
Mainstream Sidestream
Products may not be available in all geographies, please check with your Philips representative for complete portfolio availability.
452299160511.indd 4452299160511.indd 4 03/12/2020 10:5103/12/2020 10:51
This printed copy is not an official Philips hard copy, use for reference only
5
Short-term Long-term
M2760AAdult CO2/O2
oral/nasal
M2756AAdult CO
2
oral/nasal
M2761APediatric CO2/O2
oral/nasal
989803197941 Pediatric CO
2
nasal
Oral/nasal Oral/nasalOral/nasal Oral/nasalNasal NasalNasal Nasal
989803197981Adult CO2/O2
oral/nasal
989803197961Adult CO
2
oral/nasal
989803197991Pediatric CO2/O2
oral/nasal
989803197971Pediatric CO
2
oral/nasal
Non-intubated
M2750AAdult CO2/O2
nasal
M2744AAdult CO
2
nasal
M2751APediatric CO2/O2
nasal
M2745APediatric CO
2
nasal
989803197931Adult CO2/O2
nasal
989803197901Adult CO
2
nasal
989803197911Pediatric CO
2
nasal
M2757A Pediatric CO
2
oral/nasal
989803144471Infant/neo CO2/O2
nasal
M2746AInfant/neo CO
2
nasal
989803197951Infant/neo CO2/O2
nasal
989803197921Infant/neo CO
2
nasal
No O2 delivery No O2 deliveryO2 delivery O2 delivery
Ad
ult
Pe
dia
tric
Infa
nt/
Ne
on
ata
l
Products may not be available in all geographies, please check with your Philips representative for complete portfolio availability.
452299160511.indd 5452299160511.indd 5 03/12/2020 10:5103/12/2020 10:51
This printed copy is not an official Philips hard copy, use for reference only
6
Mainstream sensor Sidestream sensor
Part number M2501A M2741A
Initialization time Full specifications within two minutes, waveform data in less than 15 seconds at an ambient temperature of 25°C
Full specifications within two minutes, waveform data in less than 20 seconds at an ambient temperature of 25°C
Measurement range 0 to 150 mmHg, 0 to 19.7%, 0 to 20 kPa (at 760 mmHg) 0 to 150 mmHg, 0 to 19.7%, 0 to 20 kPa (at 760 mmHg)
Accuracy0 - 40 mmHg41 - 70 mmHg71 - 100 mmHg101 - 150 mmHg
± 2% mmHg± 5% of reading± 8% of reading± 10% of reading
± 2% mmHg± 5% of reading± 8% of reading± 10% of reading
Sample flow rate N/A 50 ml/min; ±10 ml/min
CO2 stability (drift)Short-termLong-term
Drift over four hours shall not exceed 0.8 mmHgAccuracy specification will be maintained over a 120-hour period
Drift over four hours shall not exceed 0.8 mmHgAccuracy specification will be maintained over a 120-hour period
Calibration No routine calibration required No routine calibration required
Physical characteristics
Size 35 x 48 x 23 mm (HxWxD) 38 x 66 x 89 mm (HxWxD)
Weight 25 gm (0.88 oz) 272 gm (9.6 oz)
Cable length 3 m (9.8 ft) 1 m (3.38 ft)
Temperature and humidity, operating 0 to 45°C, 10 to 90% RH, non-condensing 0 to 40°C, 10 to 90% RH, non-condensing
Storage -40 to 70°C, <90% RH, non-condensing -40 to 70°C, <90% RH, non-condensing
Water resistance IPX4-splashproof (sensor head only) IPX4-splashproof
Shock resistance IEC TR 60721-4-7 Class 7M3 (designed to withstand environments subject to significant vibrations or high shock levels); EN60068-2-27 shock, EN60068-2-64 random vibration.Able to withstand repeated six-foot drops on to tiled floor while operating.
IEC TR 60721-4-7 Class 7M3 (designed to withstand environments subject to significant vibrations or high shock levels); EN60068-2-27 shock, EN60068-2-64 random vibration.Able to withstand a three-foot drop.
Data output CO2 gas concentration (mmHg), end-tidal CO2, inspired CO2, respiratory rate
CO2 gas concentration (mmHg), end-tidal CO2, inspired CO2, respiratory rate
Comparison chart Mainstream versus sidestream monitoring
452299160511.indd 6452299160511.indd 6 03/12/2020 10:5103/12/2020 10:51
This printed copy is not an official Philips hard copy, use for reference only
7
Order all of your capnography consumables from a single source. Mainstream or sidestream. Short-term or long-term. Adult, pediatric, infant or neonate. Surgical suite, intensive care unit, emergency room, general ward, procedural sedation – and more. Whatever your capnography needs, you can find the answer with Philips.
452299160511.indd 7452299160511.indd 7 03/12/2020 10:5103/12/2020 10:51
This printed copy is not an official Philips hard copy, use for reference only
Philips Medical Systems3000 Minuteman RoadAndover, MA 01810 USA
www.philips.com
Printed in the Netherlands.4522 991 60511 * DEC 2020
© 2020 Koninklijke Philips N.V. All rights are reserved.Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.
452299160511.indd 8452299160511.indd 8 03/12/2020 10:5103/12/2020 10:51
This printed copy is not an official Philips hard copy, use for reference only