2
MANUFACTURER’S CERTIFICATION is an ENERGY STAR ® partner. fiberglass entrance doors have been tested by ETC Laboratories, Inc., verified by NAMI, and meet NFRC requirements. fiberglass entrance doors that display a permanent NFRC label on the stile of the door have been tested in accordance with NFRC 100 for U-factor and SHGC. doors that display a permanent NFRC label on the stile of the door, meet ENERGY STAR ® requirements in all fifty states and may qualify for tax credits as defined by the Tax Relief Unemployment Insurance Reauthorization, and Job Creation Act of 2010. Products that earn the ENERGY STAR ® meet strict energy efficiency guidelines set by the US Environmental Protection Agency and the Department of Energy. CERTIFICATION STATEMENT Under penalties of perjury, I declare that I have examined this certification statement, and to the best of my knowledge and belief, the facts presented are true, correct and complete. Kip Stuebs General Plant Manager Mastercraft® Doors ENERGY STAR ® and the ENERGY STAR ® mark are registered US marks. CERTIFIED ENERGY PERFORMANCE RATINGS Inswing or Outswing Door CPD# MID-M-2 Insulated Fiberglass Door PRODUCT DESCRIPTION* Default frame** Wood Individual Option Number ¼ Lite ≤ 410† ½ Lite ≤ 900† ¾ Lite ≤ 1100† Full Lite > 1100† IG/Clear/Air/0.25 IG/Clear/Air/0.75 IG/Clear/Air/0.25 with Grid IG/Clear/Air/ 0.50 ⁄ 0.81 w Blinds IG/0.14 (#2)/LowE/ Air/.0.50 with Blinds IG/0.20(3)/LowE/ Air/.0.75 IG/0.20(3)/LowE/ Air/.0.75 with Grid Triple Panel Decorative Flush / Embossed Air Leakage Manufacturer stipulates that these ratings conform to applicable NFRC procedures for determining whole product Consult manufacturer’s literature for other product performance information. * #glazing layers/spacer type/low-e per NFRC 100 †square inches 1btu/hr*ft2°F e.g., ABC-X-1-00001-00001 or 123-X-1-0001-00001 www.nfrc.org DO NOT REMOVE UNTIL AFTER FINAL INSPECTION 06360-00001 ----- ----- ----- 0.25 0.10 --- --- --- --- --- --- 06488-00001 ----- ----- ----- 0.24 0.10 --- --- --- --- --- --- 06548-00001 ----- ----- ----- 0.25 0.09 --- --- --- --- --- --- ----- 07304-00001 ----- ----- --- --- 0.23 0.14 --- --- --- --- ----- 07306-00001 ----- 07307-0001 --- --- 0.22 0.12 --- --- 0.25 0.21 06640-00001 ----- 06642-00001 ----- 0.22 0.08 --- --- 0.28 0.20 --- --- 06644-00001 ----- 06646-00001 ----- 0.22 0.07 --- --- 0.28 0.18 --- --- 07234-00001 07235-0001 06538-00001 ----- 0.22 0.09 0.25 0.15 0.27 0.21 --- --- 0.16 0.17 0.01 0.01 05447-00001 05446-00001 ≤0.3 cfm/ft 2 Certified in Highlighted Regions. Certificado Certified/Certificado For full information, see label on product. Para información completa, consultar la etiqueta del producto.

MANUFACTURER’S CERTIFICATION ... - MASTERCRAFT® Doors · 100/200 for U-factor and SHGC. This manufacturer’s certification statement is for Mastercraft® inswing and outswing

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MANUFACTURER’S CERTIFICATION ... - MASTERCRAFT® Doors · 100/200 for U-factor and SHGC. This manufacturer’s certification statement is for Mastercraft® inswing and outswing

MANUFACTURER’S CERTIFICATION is an ENERGY STAR® partner.

fiberglass entrance doors have been tested by ETCLaboratories, Inc., verified by NAMI, and meet NFRC requirements.

fiberglass entrance doors that display a permanentNFRC label on the stile of the door have been tested in accordance withNFRC 100 for U-factor and SHGC.

doors that display a permanent NFRC label on thestile of the door, meet ENERGY STAR® requirements in all fifty statesand may qualify for tax credits as defined by the Tax Relief UnemploymentInsurance Reauthorization, and Job Creation Act of 2010.

Products that earn the ENERGY STAR® meet strict energy efficiency guidelines set by the US Environmental Protection Agency and theDepartment of Energy.

CERTIFICATION STATEMENT Under penalties of perjury, I declare that I have examined this certification statement, and to the best of my knowledge and belief, the facts presented are true, correct and complete.

Kip Stuebs General Plant Manager Mastercraft® Doors

ENERGY STAR® and the ENERGY STAR® mark are registered US marks.

CERTIFIED

ENERGY PERFORMANCE RATINGS

Inswing or Outswing DoorCPD# MID-M-2

Insulated Fiberglass Door

PRODUCTDESCRIPTION*Default frame**

Wood

Individual Option Number

¼ Lite≤ 410†

½ Lite≤ 900†

¾ Lite≤ 1100†

Full Lite> 1100†

IG/Clear/Air/0.25

IG/Clear/Air/0.75

IG/Clear/Air/0.25with Grid

IG/Clear/Air/0.50 ⁄0.81 w Blinds

IG/0.14 (#2)/LowE/Air/.0.50 with Blinds

IG/0.20(3)/LowE/Air/.0.75

IG/0.20(3)/LowE/Air/.0.75 with Grid

Triple PanelDecorative

Flush / EmbossedAir LeakageManufacturer stipulates that these ratings conform to applicable NFRC procedures for determining whole product

Consult manufacturer’s literature for other product performance information. * #glazing layers/spacer type/low-eper NFRC 100 †square inches 1btu/hr*ft2°F

e.g., ABC-X-1-00001-00001 or 123-X-1-0001-00001 www.nfrc.org

DO NOT REMOVE UNTIL AFTER FINAL INSPECTION

06360-00001 ----- ----- -----

0.250.10

------

------

------

06488-00001 ----- ----- -----

0.240.10

------

------

------

06548-00001 ----- ----- -----

0.250.09

------

------

------

----- 07304-00001 ----- -----

------

0.230.14

--- ---

------

----- 07306-00001 ----- 07307-0001

------

0.220.12

------

0.250.21

06640-00001 ----- 06642-00001 -----

0.220.08

------

0.280.20

------

06644-00001 ----- 06646-00001 -----

0.220.07

------

0.280.18

------

07234-00001 07235-0001 06538-00001 -----

0.220.09

0.250.15

0.270.21

------

0.16 0.170.01 0.01 05447-0000105446-00001

≤0.3 cfm/ft2

Certified in Highlighted Regions.Certificado

Certified/Certificado

For full information, see label on product.Para información completa, consultar la etiqueta del producto.

Fiberglass 9" 2018.indd 2 11/1/18 10:20 AM

Page 2: MANUFACTURER’S CERTIFICATION ... - MASTERCRAFT® Doors · 100/200 for U-factor and SHGC. This manufacturer’s certification statement is for Mastercraft® inswing and outswing

Manufacturer’sCertification Midwest Manufacturing 5311 Kane Rd., Eau Claire, WI 54703

fiberglass entrance doors have been tested by ATI Laboratories, verified by NAMI, and meet NFRC requirements. fiberglass entrance doors that display a permanent NFRC label on the stile of the door have been tested in accordance with NFRC 100/200 for U-factor and SHGC. This manufacturer’s certification statement is for Mastercraft® inswing and outswing insulated fiberglass doors that were purchased on or after January 1, 2011 through December 31, 2016. Doors listed on this sheet may be eligible to receive an energy tax credit as defined by The Tax Relief, Unemployment Insurance Reauthorization, and Job Creation Act of 2010.

Under penalties of perjury, I declare that I have examined this certification statement, and to the best of my knowledge and belief, the facts are true, correct and complete.

Kip StuebsMidwest ManufacturingPrehung Door PlantGeneral Manager

Mastercraft® Inswing or Outswing Insulated Fiberglass Door CPD# MID-M-2 Window Size Size Thickness Grid U-Factor SHGC Flush 0.16 0.01 Embossed 0.17 0.01 Fbg Door w 1/4 Lite ≤ 410 1/4” Clear 0.25 0.10 Fbg Door w 1/4 Lite ≤ 410 3/4” Clear 0.24 0.10 Fbg Door w 1/4 Lite ≤ 410 1/4” Clear with Grid 0.25 0.09 Fbg Door w 1/4 Lite ≤ 410 3/4” 0.20 (3) Low E 0.22 0.08 Fbg Door w 1/4 Lite ≤ 410 3/4” 0.20 (3) Low E with Grid 0.22 0.07 Fbg Door w 1/4 Lite ≤ 410 1” Art Glass 0.22 0.09 Fbg Door w 1/2 Lite ≤ 900 1/2”-81/100” Clear with Blinds 0.23 0.14 Fbg Door w 1/2 Lite ≤ 900 1/2” 0.14 (#2) Low E with Blinds 0.22 0.12 Fbg Door w 1/2 Lite ≤ 900 1” Art Glass 0.25 0.15Fbg Door w 3/4 Lite ≤ 1100 3/4” 0.20 (3) Low E 0.28 0.20 Fbg Door w 3/4 Lite ≤ 1100 3/4” 0.20 (3) Low E with Grid 0.28 0.18 Fbg Door w 3/4 Lite ≤ 1100 1” Art Glass 0.27 0.21 Fbg Door w Full Lite > 1100 1/2” 0.14 (#2) Low E with Blinds 0.25 0.21