12
#MH60726 Complying with USA and Canada construction directions Complying with CE norms AIR EXTRACTOR DISCHARGE VALVE TO DRAINAGE SYSTEM ON/OFF PUMP INSPECTION PANEL HOSE CONNECTED TO THE SWITCH WATER SUPPLY NETWORK ON/OFF AIR EXTRACTOR PUMP PRESSURE 4 BAR MANOMETER Phase 1 EVERY WORKING DAY - page 1 Phase 2 BIWEEKLY MAINTENANCE - Page 2 to 3 Phase 3 ROUTINE MAINTENANCE OF AIR EXTRACTOR (EVERY 2 MONTHS )- Page 4 to 5 Phase 4 ROUTINE MAINENANCE OF THE UNIT (EVERY 2 MONTHS) Page 6 to 9 created by Viola Gianfranco SMOKI srl SIMPLIFIED MANUAL - BIWEEKLY AND ROUTINE MAINTENANCE the present manual does not replace the complete version delivered with the unit FOR SOOT ABATEMENT SYSTEM SMOKI

MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

#MH60726

Complying with USA and Canada construction directions Complying with CE norms

AIR EXTRACTOR

DISCHARGE VALVE TO

DRAINAGE SYSTEM

ON/OFF PUMP INSPECTION PANEL HOSE CONNECTED TO THE

SWITCH WATER SUPPLY NETWORK

ON/OFF AIR EXTRACTOR PUMP PRESSURE 4 BAR

MANOMETER

Phase 1 EVERY WORKING DAY - page 1

Phase 2 BIWEEKLY MAINTENANCE - Page 2 to 3

Phase 3 ROUTINE MAINTENANCE OF AIR EXTRACTOR (EVERY

2 MONTHS )- Page 4 to 5

Phase 4 ROUTINE MAINENANCE OF THE UNIT (EVERY 2 MONTHS)

Page 6 to 9 created by Viola Gianfranco

SMOKI srl

SIMPLIFIED MANUAL - BIWEEKLY AND ROUTINE MAINTENANCE

the present manual does not replace the complete version delivered with the unit

FOR SOOT ABATEMENT SYSTEM SMOKI

Page 2: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

Phase 1

The unit must be switched on when the fire in the oven is started and stay on as long as

the oven is working

N.b: switch on from control panel if the unit is provided with one

orange - switch pump control

Blue - switch air extractor control

The unit must be switched off at the end of the working time, when the fire in the oven is

extinguished

Page 1

EVERY WORKING DAY

SMOKI srl

Page 3: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

Phase 2

With switched off machine.

Empty all water from the tank to eliminate the soot accumulated

in the unit. The operation must be performed before starting the fire in

the oven with switched off machine.

Turn the control lever in horizontal position as shown in the picture

Page 2

BIWEEKLY MAINTENANCE

SMOKI srl

Page 4: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

When the lever is open, water level will start to lower

until the tank is empty

When the tank is empty, turn the lever in the original position

Turn on the system.The machine starts to fill with water ut to level and the smoke wash

begins.

Page 3

SMOKI srl

Page 5: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

Phase 3

Every two months, with oven and unit off, perform an accurate maintenance of the air extractor

Unscrew the butterfly bolts to remove the motor coupled to the fan from the stainless steel spiral

Remove the stainless steel fan

Carefully remove all soot from the stainless steel blades, so as to avoid any risks of fire and/or

rotation imbalances

Page 4

SMOKI srl

ROUTINE MAINTENANCE OF AIR EXTRACTOR

Page 6: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

Reposition the fan into the stainless steel spiral

Screw the butterfly bolts to block the fan on the stainless steel spiral.

Page 5

SMOKI srl

Page 7: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

Phase 4

Every 2 months, with oven and unit off, perform an accurate maintenance of the unit.

Empty the water tank

Unscrew the 4 fastening knobs to open the inspection door

Open the auxiliary tap connected to the hose

Page 6

SMOKI srl

ROUTINE MAINTENANCE (EVERY 2 MONTHS)

Page 8: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

Clean the tank with a jet of water

Direct the jet of water towards the level float assembly hole located in the lower part of the tank.

( See pictures).

Make sure that the float assembly moves freely up and down .

Page 7

SMOKI srl

Page 9: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

Make sure that the water drain gate (lower hole ) and

water expulsion to sewer (upper hole) are always clean (see pictures).

The water expulsion hole must be always clean and free of muddy waste,

to do so, put the hose inside and clean with a high pressure jet of water.

Page 8

SMOKI srl

Page 10: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

to avoid anomalous water loss, ALWAYS MAKE SURE that there are

Water level maintenance solenoid valve

Fast water filling solenoid valve.

Water level maintenance

solenoid valve pipe connection

Fast water filling solenoid

valve pipe connection

Page 9

connection until the problem is resolved.

In the event of anomalous water loss, immediately replace the solenoid valve

SMOKI srl

VERY IMPORTANT REMARK (WITH MACHINE OFF) :

no leaks .

In the event that water leaks are found , promptly replace the parts indicated below and close the tap water

Page 11: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

After cleaning the water tank, close the auxiliary tap and turn

the control lever in the original position as shown in the picture

Close the inspection door by means of the Switch the machine on

4 fastening knobs

If the unit is working properly, the manometer above the pump

shows a pressure around 2,0 bar

Page 10

SMOKI srl

Page 12: MANUALE DI MANUT ORDINARIA SMOKI IN INGLESE · Phase 1 The unit must be switched on when the fire in the oven is started and stay on as long as the oven is working N.b: switch on

47843 Misano Adriatico (RN) ITALY

http://www.smoki.it

e mail: [email protected] - ufficio amministrazione

e mail: [email protected] - ufficio commerciale

e mail: [email protected] - magazzino

TEL. (0541) 833748- FAX (0541) 821441

SMOKI srl

Via Cella Raibano, 16/C