6
The new Acura® manual pipette line was built with the same attention that made the brand famous over several instrument generations. Introducing a slick design with easy volume reading, it also features a number of innovations making high-performance pipetting safe and agreeable. The Acura®line features: Digital display window for permanent volume visibility Exceptional, user-friendly ergonomics Lightweight Ultra-soft, effortless activation Innovative tip ejection concept Swift-set user calibration system Entirely autoclavable at 121°C The Acura® manual models 815 825 835 fixed micro macro 855 multi digital reading micropipettes Acura manual your expectations – our tradition ®

manual your expectations – our tradition digital reading ... fileAcura® 825/835 Adjustable volume micro and macropipettes Equipped with a precision digital display, the new line

Embed Size (px)

Citation preview

Page 1: manual your expectations – our tradition digital reading ... fileAcura® 825/835 Adjustable volume micro and macropipettes Equipped with a precision digital display, the new line

The new Acura® manual pipette line

was built with the same attention

that made the brand famous over

several instrument generations.

Introducing a slick design with easy

volume reading, it also features a

number of innovations making

high-performance pipetting safe

and agreeable.

The Acura®line features:

• Digital display window for permanentvolume visibility

• Exceptional, user-friendly ergonomics

• Lightweight

• Ultra-soft, effortless activation

• Innovative tip ejection concept

• Swift-set user calibration system

• Entirely autoclavable at 121°C

The Acura® manual models

815 825 835fixed micro macro

855multi

digital readingmicropipettes

Acura manualyour expectations – our tradition

®

Page 2: manual your expectations – our tradition digital reading ... fileAcura® 825/835 Adjustable volume micro and macropipettes Equipped with a precision digital display, the new line

Volume

μL

151010Y1520253040506070758090100120150200

Imprecision

(CV %)

< 2.0 %< 1.0 %< 0.7 %< 0.8 %< 0.5 %< 0.5 %< 0.6 %< 0.6 %< 0.5 %< 0.5 %< 0.6 %< 0.6 %< 0.5 %< 0.4 %< 0.3 %< 0.3 %< 0.4 %< 0.3 %< 0.4 %

Inaccuracy

(E %)

<+/– 2.0 %<+/– 1.4 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %

Volume

μL

2503004005006007007508009001000

Imprecision

(CV %)

< 0.4 %< 0.4 %< 0.3 %< 0.3 %< 0.3 %< 0.2 %< 0.2 %< 0.2 %< 0.2 %< 0.2 %

Inaccuracy

(E %)

<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.6 %

Volume

mL

22.5510

Imprecision

(CV %)

< 0.5 %< 0.5 %< 0.4 %< 0.2 %

Inaccuracy

(E %)

<+/– 0.8 %<+/– 0.8 %<+/– 0.7 %<+/– 0.5 %

Fixed volume – unlimited

The air displacement fixed volume pipettes come with all goodfeatures of the new instrument generation. These include slimergonomic design, ultra-soft plunger stroke, autoclavability,and much more. Available in a wide selection of 1, 5 and 10 μLultra-micro volumes, micro sizes from 10 to 1000 μL, andmacro volumes models of 2 mL, 2.5 mL, 5 mL and 10 mL.

Engineered ergonomics and design

The challenge for our engineers in combining high-tech material with

ergonomic design was far above average, and they succeeded excellently.

Whether in research or routine applications, the result is an instrument

designed and built with the users in mind. The precision pipettes offer

much more than superior performance. Enjoy exceptional convenience,

comfort, safety and sturdiness, enjoy your Acura®.

Digital display always visible at

a glance

Located on the front of theinstrument, the display window allowsset volume to be visible at all timesduring pipetting. A comfortingreassurance for the user.

Tip ejection – easier than ever

Most ergonomically positioned, the largesurface, soft padded ejector buttonprovides for low-pressure activation. Inaddition to ease of tip ejection, the shaftheight adjustment system called Justip™(4 mm span) – controlled by efficientclick-stops – allows a wide selection oftips to tightly fit the nozzle.

Smart and reliable

volume adjustment

State-of-the-art micrometric volumesetting is performed smoothly andprecisely by turning push button.Finely machined click-stops and freerotating cap prevent any unwantedvolume alteration.

Acura® 815

Most comfortable pipetting

Ergonomic shape, lightweight andultra-soft plunger travel are keyelements of the new Acura® family.

Performance

815fixed

825micro

1 – 10 μL

2 – 20 μL

5 – 50 μL

0.1 – 2 μL

0.5 – 10 μL

1 μL to 10 mL

Workstation 337

Stable, sturdy universalpipette workstation 337for 7 micropipettes ofmost brands. Availablein four attractive colours.

2

Acura manualyour expectations – our tradition

®

Page 3: manual your expectations – our tradition digital reading ... fileAcura® 825/835 Adjustable volume micro and macropipettes Equipped with a precision digital display, the new line

Acura® 825/835

Adjustable volume micro and macropipettes

Equipped with a precision digital display, the new line is continously adjustabledown to a very fine volume resolution. Single-handed volume setting is easy whenthe other hand is busy. Measuring unknown volumes by aspiration is also possiblewith a high degree of accuracy. Click-stops, together with freely rotating smartie

plunger button cap ensure setting stability while pipetting.

A total of 8 micropipettes covering the range from 0.1 to 1000 μL and 2 macropipettes ranging 0.5 – 5 mL and 1 – 10 mL are available.

Workstation 340

Convenient workstationfor 3 Calibra® or Acura®,multi- or single-channelpipettes.

Swift-set calibration

The swift-set user calibration system –with integrated key and lockingmechanism – makes tedious proceduresa thing of the past. Easy and precise,it is in full compliance with internationalstandards and recommendations.835

macro

10 – 100 μL

20 – 200 μL

100 – 1000 μL 0.5 – 5 mL 1 – 10 mL

Minimum maintenance/sterilisation

Shock, heat, chemicals and UV lightresistance is provided by carefullyselected materials and goodconstruction. Consequently,maintenance requirementsare close to non-existant.

Thorough cleaning andsterilisation can be achieved byautoclaving the instrument fullyassembled (121°C, 20 minutes).

121˚C

3

Performance

Volume

range

0.1 – 2 μL0.5 – 10 μL1 – 10 μL 3)

2 – 20 μL5 – 50 μL

10 – 100 μL20 – 200 μL

100 – 1000 μL

Min. vol.

<+/– 6.0 % 1)

<+/– 2.0 % 2)

<+/– 2.0 %<+/– 2.0 %<+/– 1.4 %<+/– 1.0 %<+/– 1.0 %<+/– 0.7 %

Min. vol.

< 5.0 % 1)

< 1.8 % 2)

< 2.5 %< 1.7 %< 1.0 %< 1.0 %< 0.6 %< 0.5 %

Max. vol.

<+/– 2.0 %<+/– 1.0 %<+/– 1.0 %<+/– 1.0 %<+/– 1.0 %<+/– 0.8 %<+/– 0.8 %<+/– 0.5 %

Max. vol.

< 1.5 %< 0.5 %< 0.7 %< 0.5 %< 0.5 %< 0.2 %< 0.2 %< 0.2 %

0.5 – 5 mL1 – 10 mL

<+/– 1.0 %<+/– 0.8 %

< 0.6 %< 0.4 %

<+/– 0.7 %<+/– 0.5 %

< 0.4 %< 0.2 %

1) At 0.5 μL. Indicative data at 0.2 μL: E <+/– 12 %, CV < 8 %2) At 1.0 μL. Indicative data at 0.5 μL: E <+/– 5 %, CV < 3 %3) Fits yellow style 200 μL tips

Micropipettes

Macropipettes

Inaccuracy (E%) Imprecision (CV%)

Macropipettes – maxi advantages

The 835 models accommodate nozzlefilters for added protection againstliquid fill and contamination.

Optional adapter-nozzle allows fittingof Pasteur pipettes on 5 mL model,in addition to Polypropylene tips(order accessory separately).

Colour coding at will

The Acura® pipettes have colour-codeddisplay windows and smarties buttoncaps suggesting a selection of suitabletips. Are other colour combinationdesirable for individual, lab or departmentidentification? Then choose among14 colours of smarties, or pick thesmartie mix which contains all colours.

Page 4: manual your expectations – our tradition digital reading ... fileAcura® 825/835 Adjustable volume micro and macropipettes Equipped with a precision digital display, the new line

10 μL

10 μL

10 μL

200 μL

200 μL

200 μL

200 μL

200 μL

200 μL

350 μL

1000 μL

1000 μL

1000 μL

1000 μl

5 mL

10mL

309.0010R

302.0010GR

302.0020R

307.0200R

327.0200R

308.0200R

308.0200GR

309.0200R

329.0200R

308.0350R

307.1000R

318.1000R

309.1000R

319.1000R

312.05R

312.10ER

309.0010B

302.0020B

307.0200B

327.0200B

308.0200B

309.0200B

329.0200B

308.0350B

307.1000B

318.1000B

309.1000B

319.1000B

312.05B

312.10

10 x 96/rack

4 x 204/rack

10 x 96/rack

10 x 96/rack

10 x 96/rack

10 x 96/rack

4 x 204/rack

10 x 96/rack

10 x 96/rack

10 x 96/rack

10 x 60/rack

10 x 60/rack

10 x 60/rack

10 x 60/rack

2 x 50/rack

4 x rack alone

1 x 1000/bag

1 x 1000/bag

2 x 500/bag

2 x 500/bag

1 x 1000/bag

2 x 500/bag

2 x 500/bag

1 x 1000/bag

4 x 250/bag

4 x 250/bag

4 x 250/bag

4 x 250/bag

2 x 250/bag

3 x 100/bag

Natural ultra-microtip

Natural gel loading tip

Natural microtip

Natural universal tip

Yellow universal tip

Natural tip

Natural gel loading tip

Natural tip

Yellow tip

Natural tip

Natural universal tip

Blue tip

Natural tip

Blue tip

Natural macrotip

Natural macrotip

Volume Cat. No. Cat. No.Racks BagsDescription

Qualitips® with filter

Efficient protection against aerosols. Include high-density PE filter for completeuncontaminated sample retrieval. Certified DNAse and RNAse free. Sterile tips areguaranteed pyrogenfree.

Qualitips® without filter

These superior pipette tips cover a range between 0.1 μL and 10 mL. All models autoclavable.Optimal tightness fitting on Socorex pipettes and broad compatibility with other brands.

4

Qualitips®

Volume Cat. No. Cat. No.Racks BagsDescription

10 μL

10 μL

10 μL

20 μL

20 μL

20 μL

100 μL

100 μL

100 μL

200 μL

300 μL

300 μL

1000 μL

1000 μL

309.0010FR

302.0010FR

302.0010AFR

308.0020FR

308.0020AFR

308.0020GFR

308.0100FR

308.0100AFR

308.0100GFR

308.0200LFR

308.0300FR

308.0300AFR

309.1000FR

302.0010AFB

308.0020FS

308.0100AFB

308.0200LFS

308.0300AFB

309.1000FS

309.1000AFB

10 x 96/rack

10 x 100/rack

10 x 100/rack

10 x 96/rack

10 x 96/rack

4 x 204/rack

10 x 96/rack

10 x 96/rack

4 x 204/rack

4 x 204/rack

10 x 96/rack

10 x 96/rack

10 x 100/rack

1 x 1000/bag

5 x 100/bag

1x 1000/bag

5 x 100/bag

1 x 1000/bag

5 x 100/bag

1 x 1000/bag

Sterile ultra-microtip

Sterile microtip

Autoclavable microtip

Sterile tip

Autoclavable tip

Sterile gel loading tip

Sterile tip

Autoclavable tip

Sterile gel loading tip

Sterile extended tip

Sterile tip

Autoclavable tip

Sterile tip

Autoclavable tip

B = bag, F = filter, G = gel loading, L = long, R = rack, S = single wrapped, A = autoclavable

your premium pipette tips

Page 5: manual your expectations – our tradition digital reading ... fileAcura® 825/835 Adjustable volume micro and macropipettes Equipped with a precision digital display, the new line

Optimal working position

In addition to the ergonomic designand perfect hand fitting of the pipette,the multichannel volumetric modulesrevolves to allow the selection of thebest working position.

Acura® 855

Multichannel micropipettes

The comprehensive Acura® manual line offers 8- and 12-channel models withvolumes ranging from 0.5 to 350 μL. These multichannel instruments extendpipetting possibilities in microplates and include the same Acura original featuressuch as light weight and effortless activation. Autoclavable fully assembled by 121°C.

Adjustable tip ejector

Position of tip ejector can beadjusted in no time with a 4 mmspan to perfectly match to tipsused. Particular shape of ejectorhead adds to effortless, easysequential tip ejection.

All purpose reservoirs

Well adapted for multichannel pipettes,the reagent reservoirs offer variousshapes in different configurations ateconomical cost.

855multi

Workstation 340

Convenient workstationfor 3 Calibra® or Acura®,multi- or single-channelpipettes.

Performance

Volume

range μL

0.5 – 105 – 50

20 – 20040 – 350

Min. vol.

<+/– 3.5 % 1)

<+/– 1.0 %<+/– 0.9 %<+/– 1.0 %

Min. vol.

< 3.0 %< 1.0 %< 0.6 %< 0.6 %

Max. vol.

<+/– 1.5 %<+/– 0.8 %<+/– 0.7 %<+/– 0.8 %

Max. vol.

< 1.0 %< 0.4 %< 0.3 %< 0.3 %

1) At 1.0 μL. Indicative data at 0.5 μL: E <+/– 5 %, CV < 3 %

Inaccuracy (E%) Imprecision (CV%)

5

0.5 – 10 μL

5 – 50 μL

20 – 200 μL

40 – 350 μL

Page 6: manual your expectations – our tradition digital reading ... fileAcura® 825/835 Adjustable volume micro and macropipettes Equipped with a precision digital display, the new line

SOCOREX ISBA SA

Champ-Colomb 7, P.O. Box

1024 Ecublens/Lausanne

Switzerland

[email protected]

www.socorex.com

Tel: +41 (0)21 651 6000

Fax: +41 (0)21 651 6001

digital readingmicropipettes

Description

Work station model 340

Fits 3 multi- or single-channel

Packaging

1 / pack

Cat. No.

320.340

Universal work station model 337

Fits 7 single-channel micropipettes of most brands Light grey Ice blue Vanilla yellow Mint green

1 / pack1 / pack1 / pack1 / pack

320.337G320.337B320.337Y320.337M

1 / pack 1.835.633

Colour

WhiteGreyVanillaLemonYellowOrangeRed

Pasteur pipette adapter-nozzle

for model 835, 5 mL

Colour

RosePinkPurpleIce blueBlueMintGreen

Cat. No.

1.825.7191.825.7201.825.7211.825.7221.825.7131.825.7231.825.711

Cat. No.

1.825.7101.825.7151.825.7161.825.7121.825.7171.825.7181.825.714

Smartie mix

Assorted colours (14 / pack) 1.825.700

Smartie plunger caps

Alternative colour selection (6 / pack)

Description

Reagent reservoir, 70 mL, PP, autoclavableLarge reagent reservoir with hinged lid, 175 mL, PP, autoclavable8-channel reservoir, 40 mL, PS, sterile, single wrapped12-channel reservoir, 40 mL, PS, sterile, single wrappedNozzle protection filter for 5 mL modelNozzle protection filter for 10 mL model

Cat. No.

330.01330.01L330.08.9330.12.9322.05322.10

Packaging

20 / pack20 / pack10 / pack10 / pack250 / pack100 / pack

Reservoirs and filters

Standards and compliance

The Acura® manual pipettes aredesigned to operate under national andinternational standards such as EN ISO8655, DIN 12650, GMP, GLP, NCCLS.The instruments conform to the CEdirective IVD 98/79 EEC (in vitrodiagnostic medical devices).

QC and warranty

Performance values are obtained with bi-dest. water at constant temperature(± 0.5°C) between 20 and 25°C, inaccordance with EN ISO 8655 / DIN 12650.Each instrument bears its own serialnumber and passes strictperformance control attestedby an individual QC certificate.Three year warranty.

B.A

CU

.E –

B5

05

Acura manualyour expectations – our tradition

®

Ordering information – Accessories

Ordering information – Instruments

Volume μL

0.5 – 105 – 50

20 – 20040 – 350

Division μL

0.010.10.20.4

Tip style

10 μL200 μL200 μL350 μL

8-channel/Cat. No.

855.08.010855.08.050855.08.200855.08.350

12-channel/Cat. No.

855.12.010855.12.050855.12.200855.12.350

Acura® 855, multichannel macropipettes

Volume mL

22.5510

Cat. No.

835.F02835.F02.5835.F05835.F10

Tip style

5 mL5 mL5 mL10 mL

Acura® 835F, fixed volume macropipettes

Volume μL

151010Y152025304050

Cat. No.

815.0001815.0005815.0010815.0010Y815.0015815.0020815.0025815.0030815.0040815.0050

Tip style

10 μL10 μL10 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL

Volume μL

6070758090100120150200

Cat. No.

815.0060815.0070815.0075815.0080815.0090815.0100815.0120815.0150815.0200

Tip style

200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL

Volume μL

2503004005006007007508009001000

Cat. No.

815.0250815.0300815.0400815.0500815.0600815.0700815.0750815.0800815.0900815.1000

Tip style

1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL

Acura® 815, fixed volume micropipettes

Volume mL

0.5 – 51 – 10

Cat. No.

835.05835.10

Div. mL

0.010.01

Tip style

5 mL10 mL

Acura® 835, adjustable volume macropipettes

Volume μL

0.1 – 20.5 – 101 – 102 – 205 – 50

10 – 10020 – 200

100 – 1000

Cat. No.

825.0002825.0010825.0010Y825.0020825.0050825.0100825.0200825.1000

Div. μL

0.0020.010.010.020.10.10.21

Tip style

10 μL10 μL200 μL200 μL200 μL200 μL200 μL1000 μL

Acura® 825, adjustable volume micropipettes

6

S+