Upload
truongdiep
View
213
Download
0
Embed Size (px)
Citation preview
The new Acura® manual pipette line
was built with the same attention
that made the brand famous over
several instrument generations.
Introducing a slick design with easy
volume reading, it also features a
number of innovations making
high-performance pipetting safe
and agreeable.
The Acura®line features:
• Digital display window for permanentvolume visibility
• Exceptional, user-friendly ergonomics
• Lightweight
• Ultra-soft, effortless activation
• Innovative tip ejection concept
• Swift-set user calibration system
• Entirely autoclavable at 121°C
The Acura® manual models
815 825 835fixed micro macro
855multi
digital readingmicropipettes
Acura manualyour expectations – our tradition
®
Volume
μL
151010Y1520253040506070758090100120150200
Imprecision
(CV %)
< 2.0 %< 1.0 %< 0.7 %< 0.8 %< 0.5 %< 0.5 %< 0.6 %< 0.6 %< 0.5 %< 0.5 %< 0.6 %< 0.6 %< 0.5 %< 0.4 %< 0.3 %< 0.3 %< 0.4 %< 0.3 %< 0.4 %
Inaccuracy
(E %)
<+/– 2.0 %<+/– 1.4 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %
Volume
μL
2503004005006007007508009001000
Imprecision
(CV %)
< 0.4 %< 0.4 %< 0.3 %< 0.3 %< 0.3 %< 0.2 %< 0.2 %< 0.2 %< 0.2 %< 0.2 %
Inaccuracy
(E %)
<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.7 %<+/– 0.6 %
Volume
mL
22.5510
Imprecision
(CV %)
< 0.5 %< 0.5 %< 0.4 %< 0.2 %
Inaccuracy
(E %)
<+/– 0.8 %<+/– 0.8 %<+/– 0.7 %<+/– 0.5 %
Fixed volume – unlimited
The air displacement fixed volume pipettes come with all goodfeatures of the new instrument generation. These include slimergonomic design, ultra-soft plunger stroke, autoclavability,and much more. Available in a wide selection of 1, 5 and 10 μLultra-micro volumes, micro sizes from 10 to 1000 μL, andmacro volumes models of 2 mL, 2.5 mL, 5 mL and 10 mL.
Engineered ergonomics and design
The challenge for our engineers in combining high-tech material with
ergonomic design was far above average, and they succeeded excellently.
Whether in research or routine applications, the result is an instrument
designed and built with the users in mind. The precision pipettes offer
much more than superior performance. Enjoy exceptional convenience,
comfort, safety and sturdiness, enjoy your Acura®.
Digital display always visible at
a glance
Located on the front of theinstrument, the display window allowsset volume to be visible at all timesduring pipetting. A comfortingreassurance for the user.
Tip ejection – easier than ever
Most ergonomically positioned, the largesurface, soft padded ejector buttonprovides for low-pressure activation. Inaddition to ease of tip ejection, the shaftheight adjustment system called Justip™(4 mm span) – controlled by efficientclick-stops – allows a wide selection oftips to tightly fit the nozzle.
Smart and reliable
volume adjustment
State-of-the-art micrometric volumesetting is performed smoothly andprecisely by turning push button.Finely machined click-stops and freerotating cap prevent any unwantedvolume alteration.
Acura® 815
Most comfortable pipetting
Ergonomic shape, lightweight andultra-soft plunger travel are keyelements of the new Acura® family.
Performance
815fixed
825micro
1 – 10 μL
2 – 20 μL
5 – 50 μL
0.1 – 2 μL
0.5 – 10 μL
1 μL to 10 mL
Workstation 337
Stable, sturdy universalpipette workstation 337for 7 micropipettes ofmost brands. Availablein four attractive colours.
2
Acura manualyour expectations – our tradition
®
Acura® 825/835
Adjustable volume micro and macropipettes
Equipped with a precision digital display, the new line is continously adjustabledown to a very fine volume resolution. Single-handed volume setting is easy whenthe other hand is busy. Measuring unknown volumes by aspiration is also possiblewith a high degree of accuracy. Click-stops, together with freely rotating smartie
plunger button cap ensure setting stability while pipetting.
A total of 8 micropipettes covering the range from 0.1 to 1000 μL and 2 macropipettes ranging 0.5 – 5 mL and 1 – 10 mL are available.
Workstation 340
Convenient workstationfor 3 Calibra® or Acura®,multi- or single-channelpipettes.
Swift-set calibration
The swift-set user calibration system –with integrated key and lockingmechanism – makes tedious proceduresa thing of the past. Easy and precise,it is in full compliance with internationalstandards and recommendations.835
macro
10 – 100 μL
20 – 200 μL
100 – 1000 μL 0.5 – 5 mL 1 – 10 mL
Minimum maintenance/sterilisation
Shock, heat, chemicals and UV lightresistance is provided by carefullyselected materials and goodconstruction. Consequently,maintenance requirementsare close to non-existant.
Thorough cleaning andsterilisation can be achieved byautoclaving the instrument fullyassembled (121°C, 20 minutes).
121˚C
3
Performance
Volume
range
0.1 – 2 μL0.5 – 10 μL1 – 10 μL 3)
2 – 20 μL5 – 50 μL
10 – 100 μL20 – 200 μL
100 – 1000 μL
Min. vol.
<+/– 6.0 % 1)
<+/– 2.0 % 2)
<+/– 2.0 %<+/– 2.0 %<+/– 1.4 %<+/– 1.0 %<+/– 1.0 %<+/– 0.7 %
Min. vol.
< 5.0 % 1)
< 1.8 % 2)
< 2.5 %< 1.7 %< 1.0 %< 1.0 %< 0.6 %< 0.5 %
Max. vol.
<+/– 2.0 %<+/– 1.0 %<+/– 1.0 %<+/– 1.0 %<+/– 1.0 %<+/– 0.8 %<+/– 0.8 %<+/– 0.5 %
Max. vol.
< 1.5 %< 0.5 %< 0.7 %< 0.5 %< 0.5 %< 0.2 %< 0.2 %< 0.2 %
0.5 – 5 mL1 – 10 mL
<+/– 1.0 %<+/– 0.8 %
< 0.6 %< 0.4 %
<+/– 0.7 %<+/– 0.5 %
< 0.4 %< 0.2 %
1) At 0.5 μL. Indicative data at 0.2 μL: E <+/– 12 %, CV < 8 %2) At 1.0 μL. Indicative data at 0.5 μL: E <+/– 5 %, CV < 3 %3) Fits yellow style 200 μL tips
Micropipettes
Macropipettes
Inaccuracy (E%) Imprecision (CV%)
Macropipettes – maxi advantages
The 835 models accommodate nozzlefilters for added protection againstliquid fill and contamination.
Optional adapter-nozzle allows fittingof Pasteur pipettes on 5 mL model,in addition to Polypropylene tips(order accessory separately).
Colour coding at will
The Acura® pipettes have colour-codeddisplay windows and smarties buttoncaps suggesting a selection of suitabletips. Are other colour combinationdesirable for individual, lab or departmentidentification? Then choose among14 colours of smarties, or pick thesmartie mix which contains all colours.
10 μL
10 μL
10 μL
200 μL
200 μL
200 μL
200 μL
200 μL
200 μL
350 μL
1000 μL
1000 μL
1000 μL
1000 μl
5 mL
10mL
309.0010R
302.0010GR
302.0020R
307.0200R
327.0200R
308.0200R
308.0200GR
309.0200R
329.0200R
308.0350R
307.1000R
318.1000R
309.1000R
319.1000R
312.05R
312.10ER
309.0010B
302.0020B
307.0200B
327.0200B
308.0200B
309.0200B
329.0200B
308.0350B
307.1000B
318.1000B
309.1000B
319.1000B
312.05B
312.10
10 x 96/rack
4 x 204/rack
10 x 96/rack
10 x 96/rack
10 x 96/rack
10 x 96/rack
4 x 204/rack
10 x 96/rack
10 x 96/rack
10 x 96/rack
10 x 60/rack
10 x 60/rack
10 x 60/rack
10 x 60/rack
2 x 50/rack
4 x rack alone
1 x 1000/bag
1 x 1000/bag
2 x 500/bag
2 x 500/bag
1 x 1000/bag
2 x 500/bag
2 x 500/bag
1 x 1000/bag
4 x 250/bag
4 x 250/bag
4 x 250/bag
4 x 250/bag
2 x 250/bag
3 x 100/bag
Natural ultra-microtip
Natural gel loading tip
Natural microtip
Natural universal tip
Yellow universal tip
Natural tip
Natural gel loading tip
Natural tip
Yellow tip
Natural tip
Natural universal tip
Blue tip
Natural tip
Blue tip
Natural macrotip
Natural macrotip
Volume Cat. No. Cat. No.Racks BagsDescription
Qualitips® with filter
Efficient protection against aerosols. Include high-density PE filter for completeuncontaminated sample retrieval. Certified DNAse and RNAse free. Sterile tips areguaranteed pyrogenfree.
Qualitips® without filter
These superior pipette tips cover a range between 0.1 μL and 10 mL. All models autoclavable.Optimal tightness fitting on Socorex pipettes and broad compatibility with other brands.
4
Qualitips®
Volume Cat. No. Cat. No.Racks BagsDescription
10 μL
10 μL
10 μL
20 μL
20 μL
20 μL
100 μL
100 μL
100 μL
200 μL
300 μL
300 μL
1000 μL
1000 μL
309.0010FR
302.0010FR
302.0010AFR
308.0020FR
308.0020AFR
308.0020GFR
308.0100FR
308.0100AFR
308.0100GFR
308.0200LFR
308.0300FR
308.0300AFR
309.1000FR
302.0010AFB
308.0020FS
308.0100AFB
308.0200LFS
308.0300AFB
309.1000FS
309.1000AFB
10 x 96/rack
10 x 100/rack
10 x 100/rack
10 x 96/rack
10 x 96/rack
4 x 204/rack
10 x 96/rack
10 x 96/rack
4 x 204/rack
4 x 204/rack
10 x 96/rack
10 x 96/rack
10 x 100/rack
1 x 1000/bag
5 x 100/bag
1x 1000/bag
5 x 100/bag
1 x 1000/bag
5 x 100/bag
1 x 1000/bag
Sterile ultra-microtip
Sterile microtip
Autoclavable microtip
Sterile tip
Autoclavable tip
Sterile gel loading tip
Sterile tip
Autoclavable tip
Sterile gel loading tip
Sterile extended tip
Sterile tip
Autoclavable tip
Sterile tip
Autoclavable tip
B = bag, F = filter, G = gel loading, L = long, R = rack, S = single wrapped, A = autoclavable
your premium pipette tips
Optimal working position
In addition to the ergonomic designand perfect hand fitting of the pipette,the multichannel volumetric modulesrevolves to allow the selection of thebest working position.
Acura® 855
Multichannel micropipettes
The comprehensive Acura® manual line offers 8- and 12-channel models withvolumes ranging from 0.5 to 350 μL. These multichannel instruments extendpipetting possibilities in microplates and include the same Acura original featuressuch as light weight and effortless activation. Autoclavable fully assembled by 121°C.
Adjustable tip ejector
Position of tip ejector can beadjusted in no time with a 4 mmspan to perfectly match to tipsused. Particular shape of ejectorhead adds to effortless, easysequential tip ejection.
All purpose reservoirs
Well adapted for multichannel pipettes,the reagent reservoirs offer variousshapes in different configurations ateconomical cost.
855multi
Workstation 340
Convenient workstationfor 3 Calibra® or Acura®,multi- or single-channelpipettes.
Performance
Volume
range μL
0.5 – 105 – 50
20 – 20040 – 350
Min. vol.
<+/– 3.5 % 1)
<+/– 1.0 %<+/– 0.9 %<+/– 1.0 %
Min. vol.
< 3.0 %< 1.0 %< 0.6 %< 0.6 %
Max. vol.
<+/– 1.5 %<+/– 0.8 %<+/– 0.7 %<+/– 0.8 %
Max. vol.
< 1.0 %< 0.4 %< 0.3 %< 0.3 %
1) At 1.0 μL. Indicative data at 0.5 μL: E <+/– 5 %, CV < 3 %
Inaccuracy (E%) Imprecision (CV%)
5
0.5 – 10 μL
5 – 50 μL
20 – 200 μL
40 – 350 μL
SOCOREX ISBA SA
Champ-Colomb 7, P.O. Box
1024 Ecublens/Lausanne
Switzerland
www.socorex.com
Tel: +41 (0)21 651 6000
Fax: +41 (0)21 651 6001
digital readingmicropipettes
Description
Work station model 340
Fits 3 multi- or single-channel
Packaging
1 / pack
Cat. No.
320.340
Universal work station model 337
Fits 7 single-channel micropipettes of most brands Light grey Ice blue Vanilla yellow Mint green
1 / pack1 / pack1 / pack1 / pack
320.337G320.337B320.337Y320.337M
1 / pack 1.835.633
Colour
WhiteGreyVanillaLemonYellowOrangeRed
Pasteur pipette adapter-nozzle
for model 835, 5 mL
Colour
RosePinkPurpleIce blueBlueMintGreen
Cat. No.
1.825.7191.825.7201.825.7211.825.7221.825.7131.825.7231.825.711
Cat. No.
1.825.7101.825.7151.825.7161.825.7121.825.7171.825.7181.825.714
Smartie mix
Assorted colours (14 / pack) 1.825.700
Smartie plunger caps
Alternative colour selection (6 / pack)
Description
Reagent reservoir, 70 mL, PP, autoclavableLarge reagent reservoir with hinged lid, 175 mL, PP, autoclavable8-channel reservoir, 40 mL, PS, sterile, single wrapped12-channel reservoir, 40 mL, PS, sterile, single wrappedNozzle protection filter for 5 mL modelNozzle protection filter for 10 mL model
Cat. No.
330.01330.01L330.08.9330.12.9322.05322.10
Packaging
20 / pack20 / pack10 / pack10 / pack250 / pack100 / pack
Reservoirs and filters
Standards and compliance
The Acura® manual pipettes aredesigned to operate under national andinternational standards such as EN ISO8655, DIN 12650, GMP, GLP, NCCLS.The instruments conform to the CEdirective IVD 98/79 EEC (in vitrodiagnostic medical devices).
QC and warranty
Performance values are obtained with bi-dest. water at constant temperature(± 0.5°C) between 20 and 25°C, inaccordance with EN ISO 8655 / DIN 12650.Each instrument bears its own serialnumber and passes strictperformance control attestedby an individual QC certificate.Three year warranty.
B.A
CU
.E –
B5
05
Acura manualyour expectations – our tradition
®
Ordering information – Accessories
Ordering information – Instruments
Volume μL
0.5 – 105 – 50
20 – 20040 – 350
Division μL
0.010.10.20.4
Tip style
10 μL200 μL200 μL350 μL
8-channel/Cat. No.
855.08.010855.08.050855.08.200855.08.350
12-channel/Cat. No.
855.12.010855.12.050855.12.200855.12.350
Acura® 855, multichannel macropipettes
Volume mL
22.5510
Cat. No.
835.F02835.F02.5835.F05835.F10
Tip style
5 mL5 mL5 mL10 mL
Acura® 835F, fixed volume macropipettes
Volume μL
151010Y152025304050
Cat. No.
815.0001815.0005815.0010815.0010Y815.0015815.0020815.0025815.0030815.0040815.0050
Tip style
10 μL10 μL10 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL
Volume μL
6070758090100120150200
Cat. No.
815.0060815.0070815.0075815.0080815.0090815.0100815.0120815.0150815.0200
Tip style
200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL
Volume μL
2503004005006007007508009001000
Cat. No.
815.0250815.0300815.0400815.0500815.0600815.0700815.0750815.0800815.0900815.1000
Tip style
1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL
Acura® 815, fixed volume micropipettes
Volume mL
0.5 – 51 – 10
Cat. No.
835.05835.10
Div. mL
0.010.01
Tip style
5 mL10 mL
Acura® 835, adjustable volume macropipettes
Volume μL
0.1 – 20.5 – 101 – 102 – 205 – 50
10 – 10020 – 200
100 – 1000
Cat. No.
825.0002825.0010825.0010Y825.0020825.0050825.0100825.0200825.1000
Div. μL
0.0020.010.010.020.10.10.21
Tip style
10 μL10 μL200 μL200 μL200 μL200 μL200 μL1000 μL
Acura® 825, adjustable volume micropipettes
6
S+