    KMBEEthernet Bridge/Router Module

    Kilomux-2100/2104

    INSTALLATIONAND

    OPERATIONMANUAL

    The Access Company

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    2/104

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    3/104

    KMBEEthernet Bridge/Router Module

    Kilomux-2100/2104

    Installation and Operation Manual

    Notice

    This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD").No part of this publication may be reproduced in any form whatsoever without prior writtenapproval by RAD Data Communications.

    Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other

    intellectual property or other proprietary rights relating to this manual and to the KMBE and anysoftware components contained therein are proprietary products of RAD protected underinternational copyright law and shall be and remain solely with RAD.

    KMBE is a registered trademark of RAD. No right, license, or interest to such trademark isgranted hereunder, and you agree that no such right, license, or interest shall be asserted byyou with respect to such trademark. The RAD name, logo, logotype, and the terms EtherAccess,TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registeredtrademarks of RAD Data Communications Ltd. All other trademarks are the property of theirrespective holders.

    You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or theKMBE. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute,license, or sell any product that supports substantially similar functionality as the KMBE, basedon or derived in any way from the KMBE. Your undertaking in this paragraph shall survive thetermination of this Agreement.

    This Agreement is effective upon your opening of the KMBE package and shall continue untilterminated. RAD may terminate this Agreement upon the breach by you of any term hereof.Upon such termination by RAD, you agree to return to RAD the KMBE and all copies and portionsthereof.

    For further information contact RAD at the address below or contact your local distributor.

    International Headquarters

    RAD Data Communications Ltd.

    24 Raoul Wallenberg StreetTel Aviv 69719, IsraelTel: 972-3-6458181Fax: 972-3-6498250, 6474436E-mail: [email protected]

    North America Headquarters

    RAD Data Communications Inc.

    900 Corporate DriveMahwah, NJ 07430, USATel: (201) 5291100, Toll free: 1-800-4447234Fax: (201) 5295777E-mail: [email protected]

    19882008 RAD Data Communications Ltd. Publication No. 425-217-12/08

    mailto:[email protected]:[email protected]:[email protected]:[email protected]
  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    4/104

    Limited Warranty

    RAD warrants to DISTRIBUTOR that the hardware in the KMBE to be delivered hereunder shall befree of defects in material and workmanship under normal use and service for a period of twelve(12) months following the date of shipment to DISTRIBUTOR.

    If, during the warranty period, any component part of the equipment becomes defective byreason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect,RAD shall have the option to choose the appropriate corrective action: a) supply a replacementpart, or b) request return of equipment to its plant for repair, or c) perform necessary repair atthe equipment's location. In the event that RAD requests the return of equipment, each partyshall pay one-way shipping costs.

    RAD shall be released from all obligations under its warranty in the event that the equipment hasbeen subjected to misuse, neglect, accident or improper installation, or if repairs ormodifications were made by persons other than RAD's own authorized service personnel, unlesssuch repairs by others were made with the written consent of RAD.

    The above warranty is in lieu of all other warranties, expressed or implied. There are nowarranties which extend beyond the face hereof, including, but not limited to, warranties of

    merchantability and fitness for a particular purpose, and in no event shall RAD be liable forconsequential damages.

    RAD shall not be liable to any person for any special or indirect damages, including, but notlimited to, lost profits from any cause whatsoever arising from or in any way connected with themanufacture, sale, handling, repair, maintenance or use of the KMBE, and in no event shall RAD'sliability exceed the purchase price of the KMBE.

    DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makesrelating to KMBE and for ensuring that replacements and other adjustments required inconnection with the said warranties are satisfactory.

    Software components in the KMBE are provided "as is" and without warranty of any kind. RADdisclaims all warranties including the implied warranties of merchantability and fitness for aparticular purpose. RAD shall not be liable for any loss of use, interruption of business or

    indirect, special, incidental or consequential damages of any kind. In spite of the above RADshall do its best to provide error-free software products and shall offer free Software updatesduring the warranty period under this Agreement.

    RAD's cumulative liability to you or any other party for any loss or damages resulting from anyclaims, demands, or actions arising out of or relating to this Agreement and the KMBE shall notexceed the sum paid to RAD for the purchase of the KMBE. In no event shall RAD be liable forany indirect, incidental, consequential, special, or exemplary damages or lost profits, even if RADhas been advised of the possibility of such damages.

    This Agreement shall be construed and governed in accordance with the laws of the State ofIsrael.

    Product DisposalTo facilitate the reuse, recycling and other forms of recovery of wasteequipment in protecting the environment, the owner of this RAD product isrequired to refrain from disposing of this product as unsorted municipalwaste at the end of its life cycle. Upon termination of the units use,customers should provide for its collection for reuse, recycling or other formof environmentally conscientious disposal.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    5/104

    General Safety Instructions

    The following instructions serve as a general guide for the safe installation and operation oftelecommunications products. Additional instructions, if applicable, are included inside themanual.

    Safety Symbols

    This symbol may appear on the equipment or in the text. It indicates potential

    safety hazards regarding product operation or maintenance to operator or service

    personnel.

    Danger of electric shock Avoid any contact with the marked surface while the

    product is energized or connected to outdoor telecommunication lines.

    Protective ground: the marked lug or terminal should be connected to the buildingprotective ground bus.

    Some products may be equipped with a laser diode. In such cases, a label with the

    laser class and other warnings as applicable will be attached near the optical

    transmitter. The laser warning symbol may be also attached.

    Please observe the following precautions:

    Before turning on the equipment, make sure that the fiber optic cable is intact

    and is connected to the transmitter.

    Do not attempt to adjust the laser drive current.

    Do not use broken or unterminated fiber-optic cables/connectors or look

    straight at the laser beam.

    The use of optical devices with the equipment will increase eye hazard.

    Use of controls, adjustments or performing procedures other than those

    specified herein, may result in hazardous radiation exposure.

    ATTENTION: The laser beam may be invisible

    In some cases, the users may insert their own SFP laser transceivers into the product. Users arealerted that RAD cannot be held responsible for any damage that may result if non-compliant

    transceivers are used. In particular, users are warned to use only agency approved products thatcomply with the local laser safety regulations for Class 1 laser products.

    Always observe standard safety precautions during installation, operation and maintenance ofthis product. Only qualified and authorized service personnel should carry out adjustment,maintenance or repairs to this product. No installation, adjustment, maintenance or repairsshould be performed by either the operator or the user.

    Warning

    Warning

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    6/104

    Handling Energized Products

    General Safety Practices

    Do not touch or tamper with the power supply when the power cord is connected. Line voltagesmay be present inside certain products even when the power switch (if installed) is in the OFFposition or a fuse is blown. For DC-powered products, although the voltages levels are usuallynot hazardous, energy hazards may still exist.

    Before working on equipment connected to power lines or telecommunication lines, removejewelry or any other metallic object that may come into contact with energized parts.

    Unless otherwise specified, all products are intended to be grounded during normal use.Grounding is provided by connecting the mains plug to a wall socket with a protective groundterminal. If a ground lug is provided on the product, it should be connected to the protectiveground at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipmentshould be mounted only in grounded racks and cabinets.

    Always make the ground connection first and disconnect it last. Do not connect

    telecommunication cables to ungrounded equipment. Make sure that all other cables aredisconnected before disconnecting the ground.

    Some products may have panels secured by thumbscrews with a slotted head. These panels maycover hazardous circuits or parts, such as power supplies. These thumbscrews should thereforealways be tightened securely with a screwdriver after both initial installation and subsequentaccess to the panels.

    Connecting AC Mains

    Make sure that the electrical installation complies with local codes.

    Always connect the AC plug to a wall socket with a protective ground.

    The maximum permissible current capability of the branch distribution circuit that supplies powerto the product is 16A (20A for USA and Canada). The circuit breaker in the building installationshould have high breaking capacity and must operate at short-circuit current exceeding 35A (40Afor USA and Canada).

    Always connect the power cord first to the equipment and then to the wall socket. If a powerswitch is provided in the equipment, set it to the OFF position. If the power cord cannot bereadily disconnected in case of emergency, make sure that a readily accessible circuit breaker oremergency switch is installed in the building installation.

    In cases when the power distribution system is IT type, the switch must disconnect both polessimultaneously.

    Connecting DC Power

    Unless otherwise specified in the manual, the DC input to the equipment is floating in referenceto the ground. Any single pole can be externally grounded.

    Due to the high current capability of DC power systems, care should be taken when connectingthe DC supply to avoid short-circuits and fire hazards.

    Make sure that the DC power supply is electrically isolated from any AC source and that theinstallation complies with the local codes.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    7/104

    The maximum permissible current capability of the branch distribution circuit that supplies powerto the product is 16A (20A for USA and Canada). The circuit breaker in the building installationshould have high breaking capacity and must operate at short-circuit current exceeding 35A (40Afor USA and Canada).

    Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locatethe circuit breaker of the panel board that services the equipment and switch it to the OFF

    position. When connecting the DC supply wires, first connect the ground wire to thecorresponding terminal, then the positive pole and last the negative pole. Switch the circuitbreaker back to the ON position.

    A readily accessible disconnect device that is suitably rated and approved should be incorporatedin the building installation.

    If the DC power supply is floating, the switch must disconnect both poles simultaneously.

    Connecting Data and Telecommunications Cables

    Data and telecommunication interfaces are classified according to their safety status.

    The following table lists the status of several standard interfaces. If the status of a given port

    differs from the standard one, a notice will be given in the manual.

    Ports Safety Status

    V.11, V.28, V.35, V.36, RS-530, X.21,10 BaseT, 100 BaseT, Unbalanced E1,E2, E3, STM, DS-2, DS-3, S-InterfaceISDN, Analog voice E&M

    SELV Safety Extra Low Voltage:

    Ports which do not present a safety hazard. Usuallyup to 30 VAC or 60 VDC.

    xDSL (without feeding voltage),Balanced E1, T1, Sub E1/T1

    TNV-1 Telecommunication Network Voltage-1:

    Ports whose normal operating voltage is within thelimits of SELV, on which overvoltages from

    telecommunications networks are possible.

    FXS (Foreign Exchange Subscriber) TNV-2 Telecommunication Network Voltage-2:

    Ports whose normal operating voltage exceeds thelimits of SELV (usually up to 120 VDC or telephoneringing voltages), on which overvoltages fromtelecommunication networks are not possible. Theseports are not permitted to be directly connected toexternal telephone and data lines.

    FXO (Foreign Exchange Office), xDSL(with feeding voltage), U-InterfaceISDN

    TNV-3 Telecommunication Network Voltage-3:

    Ports whose normal operating voltage exceeds thelimits of SELV (usually up to 120 VDC or telephoneringing voltages), on which overvoltages fromtelecommunication networks are possible.

    Always connect a given port to a port of the same safety status. If in doubt, seek the assistance

    of a qualified safety engineer.

    Always make sure that the equipment is grounded before connecting telecommunication cables.Do not disconnect the ground connection before disconnecting all telecommunications cables.

    Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables.Extra caution should be exercised during thunderstorms.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    8/104

    When using shielded or coaxial cables, verify that there is a good ground connection at bothends. The grounding and bonding of the ground connections should comply with the local codes.

    The telecommunication wiring in the building may be damaged or present a fire hazard in case ofcontact between exposed external wires and the AC power lines. In order to reduce the risk,there are restrictions on the diameter of wires in the telecom cables, between the equipmentand the mating connectors.

    To reduce the risk of fire, use only No. 26 AWG or larger telecommunication linecords.

    Pour rduire les risques sincendie, utiliser seulement des conducteurs detlcommunications 26 AWG ou de section suprieure.

    Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. Insuch cases, a notice will be given in the installation instructions.

    Do not attempt to tamper with any carrier-provided equipment or connection hardware.

    Electromagnetic Compatibility (EMC)

    The equipment is designed and approved to comply with the electromagnetic regulations ofmajor regulatory bodies. The following instructions may enhance the performance of theequipment and will provide better protection against excessive emission and better immunityagainst disturbances.

    A good ground connection is essential. When installing the equipment in a rack, make sure toremove all traces of paint from the mounting points. Use suitable lock-washers and torque. If anexternal grounding lug is provided, connect it to the ground bus using braided wire as short aspossible.

    The equipment is designed to comply with EMC requirements when connecting it with unshieldedtwisted pair (UTP) cables. However, the use of shielded wires is always recommended, especiallyfor high-rate data. In some cases, when unshielded wires are used, ferrite cores should beinstalled on certain cables. In such cases, special instructions are provided in the manual.

    Disconnect all wires which are not in permanent use, such as cables used for one-timeconfiguration.

    The compliance of the equipment with the regulations for conducted emission on the data linesis dependent on the cable quality. The emission is tested for UTP with 80 dB longitudinalconversion loss (LCL).

    Unless otherwise specified or described in the manual, TNV-1 and TNV-3 ports provide secondaryprotection against surges on the data lines. Primary protectors should be provided in the building

    installation.The equipment is designed to provide adequate protection against electro-static discharge (ESD).However, it is good working practice to use caution when connecting cables terminated withplastic connectors (without a grounded metal hood, such as flat cables) to sensitive data lines.Before connecting such cables, discharge yourself by touching ground or wear an ESD preventivewrist strap.

    Caution

    Attention

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    9/104

    FCC-15 User Information

    This equipment has been tested and found to comply with the limits of the Class A digital device,pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protectionagainst harmful interference when the equipment is operated in a commercial environment. This

    equipment generates, uses and can radiate radio frequency energy and, if not installed and usedin accordance with the Installation and Operation manual, may cause harmful interference to theradio communications. Operation of this equipment in a residential area is likely to cause harmfulinterference in which case the user will be required to correct the interference at his ownexpense.

    Canadian Emission Requirements

    This Class A digital apparatus meets all the requirements of the Canadian Interference-CausingEquipment Regulation.

    Cet appareil numrique de la classe A respecte toutes les exigences du Rglement sur le matriel

    brouilleur du Canada.

    Warning per EN 55022 (CISPR-22)

    This is a class A product. In a domestic environment, this product may cause radiointerference, in which case the user will be required to take adequate measures.

    Cet appareil est un appareil de Classe A. Dans un environnement rsidentiel, cetappareil peut provoquer des brouillages radiolectriques. Dans ces cas, il peut tredemand lutilisateur de prendre les mesures appropries.

    Das vorliegende Gert fllt unter die Funkstrgrenzwertklasse A. In Wohngebietenknnen beim Betrieb dieses Gertes Rundfunkstrrungen auftreten, fr derenBehebung der Benutzer verantwortlich ist.

    Warning

    Avertissement

    Achtung

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    10/104

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    11/104

    Certains produits peuvent tre quips d'une diode laser. Dans de tels cas, une

    tiquette indiquant la classe laser ainsi que d'autres avertissements, le cas chant,

    sera jointe prs du transmetteur optique. Le symbole d'avertissement laser peut

    aussi tre joint.

    Veuillez observer les prcautions suivantes :

    Avant la mise en marche de l'quipement, assurez-vous que le cble de fibre

    optique est intact et qu'il est connect au transmetteur.

    Ne tentez pas d'ajuster le courant de la commande laser.

    N'utilisez pas des cbles ou connecteurs de fibre optique casss ou sans

    terminaison et n'observez pas directement un rayon laser.

    L'usage de priphriques optiques avec l'quipement augmentera le risque pour

    les yeux.

    L'usage de contrles, ajustages ou procdures autres que celles spcifies ici

    pourrait rsulter en une dangereuse exposition aux radiations.

    ATTENTION : Le rayon laser peut tre invisible

    Les utilisateurs pourront, dans certains cas, insrer leurs propres metteurs-rcepteurs Laser SFPdans le produit. Les utilisateurs sont avertis que RAD ne pourra pas tre tenue responsable detout dommage pouvant rsulter de l'utilisation d'metteurs-rcepteurs non conformes. Plusparticulirement, les utilisateurs sont avertis de n'utiliser que des produits approuvs parl'agence et conformes la rglementation locale de scurit laser pour les produits laser declasse 1.

    Respectez toujours les prcautions standards de scurit durant l'installation, l'opration et lamaintenance de ce produit. Seul le personnel de service qualifi et autoris devrait effectuerl'ajustage, la maintenance ou les rparations de ce produit. Aucune opration d'installation,d'ajustage, de maintenance ou de rparation ne devrait tre effectue par l'oprateur oul'utilisateur.

    Manipuler des produits sous tension

    Rgles gnrales de scurit

    Ne pas toucher ou altrer l'alimentation en courant lorsque le cble d'alimentation est branch.Des tensions de lignes peuvent tre prsentes dans certains produits, mme lorsque lecommutateur (s'il est install) est en position OFF ou si le fusible est rompu. Pour les produitsaliments par CC, les niveaux de tension ne sont gnralement pas dangereux mais des risquesde courant peuvent toujours exister.

    Avant de travailler sur un quipement connect aux lignes de tension ou de tlcommunications,retirez vos bijoux ou tout autre objet mtallique pouvant venir en contact avec les pices soustension.

    Sauf s'il en est autrement indiqu, tous les produits sont destins tre mis la terre durant

    l'usage normal. La mise la terre est fournie par la connexion de la fiche principale une prisemurale quipe d'une borne protectrice de mise la terre. Si une cosse de mise la terre estfournie avec le produit, elle devrait tre connecte tout moment une mise la terre deprotection par un conducteur de diamtre 18 AWG ou plus. L'quipement mont en chssis nedevrait tre mont que sur des chssis et dans des armoires mises la terre.

    Branchez toujours la mise la terre en premier et dbranchez-la en dernier. Ne branchez pas descbles de tlcommunications un quipement qui n'est pas mis la terre. Assurez-vous quetous les autres cbles sont dbranchs avant de dconnecter la mise la terre.

    Avertissement

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    12/104

    F

    i

    Connexion au courant du secteur

    Assurez-vous que l'installation lectrique est conforme la rglementation locale.

    Branchez toujours la fiche de secteur une prise murale quipe d'une borne protectrice de mise la terre.

    La capacit maximale permissible en courant du circuit de distribution de la connexion alimentantle produit est de 16A (20A aux Etats-Unis et Canada). Le coupe-circuit dans l'installation dubtiment devrait avoir une capacit leve de rupture et devrait fonctionner sur courant decourt-circuit dpassant 35A (40A aux Etats-Unis et Canada).

    Branchez toujours le cble d'alimentation en premier l'quipement puis la prise murale. Si uncommutateur est fourni avec l'quipement, fixez-le en position OFF. Si le cble d'alimentation nepeut pas tre facilement dbranch en cas d'urgence, assurez-vous qu'un coupe-circuit ou undisjoncteur d'urgence facilement accessible est install dans l'installation du btiment.

    Le disjoncteur devrait dconnecter simultanment les deux ples si le systme de distribution decourant est de type IT.

    Connexion d'alimentation CC

    Sauf s'il en est autrement spcifi dans le manuel, l'entre CC de l'quipement est flottante parrapport la mise la terre. Tout ple doit tre mis la terre en externe.

    A cause de la capacit de courant des systmes alimentation CC, des prcautions devraienttre prises lors de la connexion de l'alimentation CC pour viter des courts-circuits et des risquesd'incendie.

    Assurez-vous que l'alimentation CC est isole de toute source de courant CA (secteur) et quel'installation est conforme la rglementation locale.

    La capacit maximale permissible en courant du circuit de distribution de la connexion alimentantle produit est de 16A (20A aux Etats-Unis et Canada). Le coupe-circuit dans l'installation dubtiment devrait avoir une capacit leve de rupture et devrait fonctionner sur courant decourt-circuit dpassant 35A (40A aux Etats-Unis et Canada).

    Avant la connexion des cbles d'alimentation en courant CC, assurez-vous que le circuit CC n'estpas sous tension. Localisez le coupe-circuit dans le tableau desservant l'quipement et fixez-leen position OFF. Lors de la connexion de cbles d'alimentation CC, connectez d'abord leconducteur de mise la terre la borne correspondante, puis le ple positif et en dernier, leple ngatif. Remettez le coupe-circuit en position ON.

    Un disjoncteur facilement accessible, adapt et approuv devrait tre intgr l'installation dubtiment.

    Le disjoncteur devrait dconnecter simultanment les deux ples si l'alimentation en courant CCest flottante.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    13/104

    Glossary

    10BaseT

    10BaseT is a LAN protocol which allows stations to be attached viatwisted pair cable.

    Address A coded representation of the origin or destination of data.

    Agent

    In SNMP, this refers to the managed system.

    Analog

    A continuous wave or signal (such as human voice).

    ARP (Address

    Resolution Protocol)

    ARP is a method for finding a host's Ethernet address from itsInternet address. The sender broadcasts an ARP packet containingthe Internet address of another host and waits for the secondhost to send back its Ethernet address.

    ARP is defined in RFC 826.

    Asynchronous

    Transmission

    Asynchronous transmission is the sending of data units character-by-character. The characters are preceded by start bits andfollowed by stop bits.

    AWG

    The American Wire Gauge System, which specifies wire width.

    Balanced

    A transmission line in which voltages on the two conductors areequal in magnitude, but opposite in polarity, with respect toground.

    Bandwidth

    The range of frequencies passing through a given circuit. Thegreater the bandwidth, the more information can be sent throughthe circuit in a given amount of time.

    Baud

    Unit of signaling speed equivalent to the number of discreteconditions or events per second. If each signal event representsonly one bit condition, baud rate equals bps (bits per second).

    Bit

    The smallest unit of information in a binary system. Representseither a one or zero (1 or 0).

    bps (Bits Per Second)

    A measure of data transmission rate in serial transmission.

    Bridge

    A device interconnecting local area networks at the OSI data linklayer, filtering and forwarding frames according to media accesscontrol (MAC) addresses.

    Bridging

    Bridging is the forwarding of traffic between network segmentsbased on data link layer information. These segments have acommon network layer address.

    Broadcast

    Broadcast is a transmission to multiple, unspecified recipients. Onan Ethernet network, a broadcast packet is a special type ofmulticast packet which all nodes on the network are always willingto receive.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    14/104

    Buffer

    A storage device. Commonly used to compensate for differencesin data rates or event timing when transmitting from one device toanother. Also used to remove jitter.

    Bus

    A transmission path or channel. A bus is typically an electricalconnection with one or more conductors, where all attached

    devices receive all transmissions at the same time.

    Byte

    A group of bits (normally 8 bits in length).

    Carrier

    A continuous signal at a fixed frequency that is capable of beingmodulated with a second (information carrying) signal.

    Channel

    A path for electrical transmission between two or more points.Also called a link, line, circuit or facility.

    CHAP

    The Challenge Handshake Authentication Protocol CHAP is anauthentication protocol used by Point to Point Protocol (PPP)servers to validate the identity of remote clients. CHAP periodicallyverifies the identity of the client by using a three-way handshakebased on a shared secret (client users password).

    Clock

    A term for the source(s) of timing signals used in synchronoustransmission.

    Compression

    Any of several techniques that reduce the number of bits requiredto represent information in data transmission or storage, therebyconserving bandwidth and/or memory.

    Congestion

    A state in which the network is overloaded and starts to discarduser data (frames, cells or packets).

    Congestion Control

    A resource and traffic management mechanism to avoid and/orprevent excessive situations (buffer overflow, insufficient

    bandwidth) that can cause the network to collapse. In ATMnetworks, congestion control schemes may be based on fieldswithin the ATM cell header (CLP, EFCI within the PTI) or may bebased on a more sophisticated mechanism between the ATM end-system and ATM switches. The ATM Forum has developed amechanism based on rate control for ABR-type traffic. In FrameRelay networks, congestion is handled by the FECN, BECN and DEbits.

    Data

    Information represented in digital form, including voice, text,facsimile and video.

    Data Link Layer

    Layer 2 of the OSI model. The entity, which establishes, maintains,and releases data-link connections between elements in anetwork. Layer 2 is concerned with the transmission of units ofinformation, or frames, and associated error checking.

    Default Gateway

    Default Gateway is a routing table entry which is used to directpackets addressed to hosts or networks not explicitly listed in therouting table.

    Diagnostics

    The detection and isolation of a malfunction or mistake in acommunications device, network or system.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    15/104

    Digital

    The binary (1 or 0) output of a computer or terminal. In datacommunications, an alternating, non-continuous (pulsating) signal.

    DLCI (Data Link Control

    Identifier)

    DLCI is a channel number which is attached to data frames to tellthe network how to route the data in Frame Relay Networks.

    DNS (Domain Name

    System)

    DNS is a general-purpose distributed, replicated, data queryservice chiefly used on Internet for translating hostnames intoInternet IP addresses.

    DNS is defined in STD 13, RFCs 1034 and 1035.

    Dynamic Station

    A dynamic station is a host which is added automatically to an ARPor LAN table.

    E3

    The European standard for high speed digital transmission,operating at 34 Mbps.

    Encapsulation

    Encapsulating data is a technique used by layered protocols inwhich a low level protocol accepts a message from a higher level

    protocol, then places it in the data portion of the lower-levelframe. The logistics of encapsulation require that packets travelingover a physical network contain a sequence of headers.

    Ethernet

    A local area network (LAN) technology which has extended intothe wide area networks. Ethernet operates at many speeds,including data rates of 10 Mbps (Ethernet), 100 Mbps (FastEthernet), 1,000 Mbps (Gigabit Ethernet), 10 Gbps, 40 Gbps, and100 Gbps.

    Firewall

    A firewall system controls access to or from a protected network(i.e., a site). It implements a network access policy by forcingconnections to pass through the firewall, where they can beexamined and evaluated.

    Frame

    A logical grouping of information sent as a link-layer unit over atransmission medium. The terms packet, datagram, segment, andmessage are also used to describe logical information groupings.

    Frame Relay

    An efficient packet switching technology providing high speedframe or packet transmission with minimum delay and efficientbandwidth utilization over virtual circuits. The link layer handlesmuch of the network layer functionality. It has less protocoloverhead than X.25.

    FXO (Foreign Exchange

    Office)

    A voice interface, emulating a PBX extension, as it appears to theCO (Central Office) for connecting a PBX extension to amultiplexer.

    FXS (Foreign Exchange

    Subscriber)

    A voice interface, emulating the extension interface of a PBX (orsubscriber interface of a CO) for connecting a regular telephoneset to a multiplexer.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    16/104

    Gateway

    Gateways are points of entrance and exit from a communicationsnetwork. Viewed as a physical entity, a gateway is that node thattranslates between two otherwise incompatible networks ornetwork segments. Gateways perform code and protocolconversion to facilitate traffic between data highways of differingarchitecture.

    Interface

    A shared boundary, defined by common physical interconnectioncharacteristics, signal characteristics, and meanings of exchangedsignals.

    IP Address

    Also known as an Internet address. A unique string of numbersthat identifies a computer or device on a TCP/IP network. Theformat of an IP address is a 32-bit numeric address written as fournumbers from 0 to 255, separated by periods (for example,1.0.255.123).

    IP Mask

    he IP mask is a unique 4 byte (32 bit) value that allow therecipient of IP packets to distinguish between different host IDs.

    IP/IPX Routing IP/IPX Routing is the process, performed by a router, of selectingthe correct interface and next hop for a packet being forwarded.Routing is done in order to send a packet to a specific destination.

    IPX (Internetwork

    Packet Exchange)

    IPX is a network layer protocol used in Novell NetWare file serveroperating system.

    ISDN (Integrated

    Services Digital

    Network)

    ISDN is a set of communications standards allowing a single wireor optical fiber to carry voice, digital network services and video.ISDN is intended to eventually replace the telephone system.

    Jitter

    The deviation of a transmission signal in time or phase. It canintroduce errors and loss of synchronization in high speedsynchronous communications.

    Laser

    A device that transmits an extremely narrow and coherent beamof electromagnetic energy in the visible light spectrum. Used as alight source for fiber optic transmission (generally more expensive,shorter lived, single mode only, for greater distances than LED).

    Latency

    The time between initiating a request for data and the beginningof the actual data transfer. Network latency is the delayintroduced when a packet is momentarily stored, analyzed andthen forwarded.

    Leased Lines

    A leased line is a private telephone circuit permanently connectingtwo points, normally provided on a lease by a local PTT.

    Loading

    The addition of inductance to a line in order to minimize amplitudedistortion. Used commonly on public telephone lines to improvevoice quality, it can make the lines impassable to high speed data,and baseband modems.

    Loopback

    A type of diagnostic test in which the transmitted signal isreturned to the sending device after passing through all or part ofa communications link or network.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    17/104

    MAC (Media Access

    Control)

    MAC is the lower sublayer of the data link layer. MAC is theinterface between a node's Logical Link Control and the network'sphysical layer. The MAC differs for various physical media.

    MAC Address

    The MAC Address is the hardware address of a device connectedto a shared network medium.

    Manager

    An application that receives Simple Network Management Protocol(SNMP) information from an agent. An agent and manager share adatabase of information, called the Management Information Base(MIB). An agent can use a message called a traps-PDU to sendunsolicited information to the manager. A manager that uses theRADview MIB can query the RAD device, set parameters, soundalarms when certain conditions appear, and perform otheradministrative tasks.

    Mask

    A mask is a filtering aid that is used to define classes ofaddresses. By defining classes, any packet can be judged as towhether it should pass the filter or not.

    MTU (Maximum

    Transmit Unit)

    The Maximum Transmission Unit is the largest frame length whichmay be sent on a physical medium.

    MultiCast

    MultiCast is an Ethernet addressing scheme used to send packetsto devices of a certain type or for broadcasting to all nodes.

    Multiplexer

    At one end of a communications link, a device that combinesseveral lower speed transmission channels into a single high speedchannel. A multiplexer at the other end reverses the process.Sometimes called a mux. See Bit Interleaving/Multiplexing.

    Network

    (1) An interconnected group of nodes. (2) A series of points,nodes, or stations connected by communications channels; the

    collection of equipment through which connections are madebetween data stations.

    Network Layer

    A layer in the OSI reference model. The network layer providesaddress resolution and routing protocols. Address resolutionenables the network layer to determine a unique network addressfor a node. Routing protocols allow data to flow betweennetworks and reach their proper destination. Examples of networklayer protocols are Address Resolution Protocol (ARP), DatagramDelivery Protocol (DDP), Internet Control Message Protocol (ICMP),Interior Gateway Protocol (IGP), Internet Protocol (IP),Internetwork Packet Exchange (IPX) and Packet Layer Protocol(PLP).

    NetBEUI (NetBIOS

    Extended User

    Interface)

    NetBEUI is the network transport protocol used by all of Microsoftnetwork systems and IBM LAN Server based systems.

    NCP (NetWare Core

    Protocol)

    NCP is a Novell trademark for the protocol used to access NovellNetWare file and print service functions. NCP uses an underlyingIPX or IP transport protocol.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    18/104

    Parity

    Parity is an extra bit added to a byte or word to reveal errors instorage (in RAM or disk) or transmission. Even/odd parity meansthat the parity bit is set so that there are an even/odd number ofone bits in the word, including the parity bit. Odd parity meansthat the parity bit is set so that there are an odd number of onebits in the word, including the parity bit.

    Node

    A point of interconnection to a network.

    Packet

    An ordered group of data and control signals transmitted througha network, as a subset of a larger message.

    Packet Switching

    A data transmission technique, which divides user information intodiscrete data envelopes called packets, and sends the informationpacket by packet.

    PAP

    The Password Authentication Protocol is a simple authenticationprotocol used by a point to point protocol (PPP) to authenticateusers to a network server. This protocol transmits unencrypted

    ASCII messages over the network and is considered unsecure. It isused if the server does not support a stronger protocol such asCHAP.

    parameters

    Parameters are often called arguments, and the two words areused interchangeably. However, some computer languages such asC define argument to mean actual parameter (i.e., the value), andparameter to mean formal parameter. In RAD CLI, parametermeans formal parameter, not value.

    Polling

    See Multidrop.

    Port

    The physical interface to a computer or multiplexer, for connectionof terminals and modems.

    PPP (Point to Point

    Protocol)

    PPP is the protocol defined in RFC 1661, the Internet standard fortransmitting network layer datagrams (e.g. IP packets) over serialpoint-to-point links.

    PPP is designed to operate both over asynchronous connectionsand bit-oriented synchronous systems, it can configureconnections to a remote network dynamically, and test that thelink is usable. PPP can be configured to encapsulate differentnetwork layer protocols (such as IP, IPX, or AppleTalk) by using theappropriate network.

    prompt

    One or more characters in a command line interface to indicatethat the computer is ready to accept typed input.

    Protocol

    A formal set of conventions governing the formatting and relativetiming of message exchange between two communicatingsystems.

    PSTN (Public Switched

    Telephone Network)

    PSTN is the collection of interconnected systems operated by thevarious telephone companies and administrations (PTTs) aroundthe world.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    19/104

    RFC (Request for

    Comment)

    RFC is a numbered Internet informational documents andstandards widely followed by commercial software and freeware inthe Internet and UNIX communities.

    RIP (Routing

    Information Protocol)

    RIP is the companion protocol to IPX for exchange of routinginformation in a Novell network. It is not related to the Internet

    protocol of the same name.

    RIP-2

    Routing information protocol used to discover agents and theroutes that IP packets must traverse. This is done automaticallyusing periodic broadcasts. RIP-2 also supports IP subnets.

    Router

    An interconnection device that connects individual LANs. Unlikebridges, which logically connect at OSI Layer 2, routers providelogical paths at OSI Layer 3. Like bridges, remote sites can beconnected using routers over dedicated or switched lines to createWANs.

    Routing

    The process of selecting the most efficient circuit path for amessage.

    SAP

    SAP is the OSI term for the component of a network addresswhich identifies the individual application on a host which issending or receiving a packet.

    Serial Transmission

    A common mode of transmission, where the character bits aresent sequentially one at a time instead of in parallel.

    Single Mode

    Describing an optical wave-guide or fiber that is designed topropagate light of only a single wavelength (typically 5-10 micronsin diameter).

    SLIP (Serial Line Internet

    Protocol)

    SLIP is software allowing the IP, normally used on Ethernet, to beused over a serial line, e.g. an RS-232 serial port connected to a

    modem. It is defined in RFC 1055.SNMP (Simple Network

    Management Protocol)

    SNMP is the Internet standard protocol, defined in STD 15, RFC1157, developed to manage nodes on an IP network.

    SOCKS

    SOCKS is a security package that allows a host behind a firewall touse finger, FTP, Telnet, Gopher, and Mosaic to access resourcesoutside the firewall while maintaining the security requirements.

    Space

    In telecommunications, the absence of a signal. Equivalent to abinary 0.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    20/104

    Spoofing

    Spoofing is a technique used to reduce network overhead,especially in wide area networks (WAN). Some network protocolssend frequent packets for management purposes. These can berouting updates or keep-alive messages. In a WAN this canintroduce significant overhead, due to the typically smallerbandwidth of WAN connections.

    Spoofing reduces the required bandwidth by having devices, suchas bridges or routers, answer for the remote devices. This fools(spoofs) the LAN device into thinking the remote LAN is stillconnected, even though it's not. The spoofing saves the WANbandwidth, because no packet is ever sent out on the WAN.

    SPX (Sequenced Packet

    Exchange)

    SPX is a transport layer protocol built on top of IPX. SPX is used inNovell NetWare systems for communications in client/serverapplication programs, e.g. BTRIEVE (ISAM manager).

    Static Station

    A static station is a host which is added manually to an ARP or LANtable.

    Stop Bit

    Stop Bits mark the end of a unit of transmission (normally a byteor character). In serial communications, where each bit of themessage is transmitted in sequence, stop bits are extra "1" bitswhich follow the data and any parity bit.

    Synchronous

    Transmission

    Transmission in which data bits are sent at a fixed rate, with thetransmitter and receiver synchronized.

    T1

    A digital transmission link with a capacity of 1.544 Mbps used inNorth America. Typically channelized into 24 DS0s, each capable ofcarrying a single voice conversation or data stream. Uses two pairsof twisted pair wires.

    TCP (Transmission

    Control Protocol)

    TCP is the most common transport layer protocol used on Ethernetand the Internet.

    TCP is built on top of Internet Protocol (IP) and is nearly alwaysseen in the combination TCP/IP (TCP over IP). It adds reliablecommunication, flow-control, multiplexing and connection-oriented communication. It provides full-duplex, process-to-process connections.

    TCP is defined in STD 7, RFC 793.

    TCP/IP stack

    (Transmission Control

    Protocol over Internet

    Protocol)

    TCP/IP stack is the standard Ethernet protocols incorporated into4.2BSD UNIX. While TCP and IP specify two protocols at specificlayers, TCP/IP is often used to refer to the entire DoD protocolsuite based upon these, including Telnet, FTP, UDP and RDP.

    Telnet

    The virtual terminal protocol in the Internet suite of protocols. Itlets users on one host access another host and work as terminalusers of that remote host. Instead of dialing into the computer,the user connects to it over the Internet using Telnet. Whenissuing a Telnet session, it connects to the Telnet host and logs in.The connection enables the user to work with the remote machineas though a terminal was connected to it.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    21/104

    TFTP (Trivial File

    Transfer Protocol)

    A simplified version of the File Transfer Protocol that transfersfiles but does not provide password protection or user-directorycapability.

    Throughput

    The amount of information transferred through the networkbetween two users in a given period, usually measured in the

    number of packets per second (pps).

    Traffic Management

    Set of actions and operations performed by the network toguarantee the operability of the network, exercised in the form oftraffic control and flow control.

    UDP (User Datagram

    Protocol)

    UDP is an Internet standard network layer, transport layer andsession layer protocols which provide simple but unreliabledatagram services. It adds a checksum and additionalprocess-to-process addressing information. UDP is aconnectionless protocol which, like TCP, is layered on top of IP.

    UDP is defined in STD 6, RFC 768.

    WAN (Wide Area

    Network)

    A WAN is a network, usually constructed with serial lines,

    extending over distances greater than one kilometer.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    22/104

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    23/104

    KMBE i

    Contents

    Chapter 1 Introduction

    1.1 Overview....................................................................................................................1-1

    Versions .................................................................................................................1-1

    1.2

    Features ....................................................................................................................1-1

    Bridging ..................................................................................................................1-2

    IP Routing ...............................................................................................................1-2

    IPX Routing .............................................................................................................1-2

    Address Translation (Single IP) and Firewall .............................................................1-2

    Solid Firewall ..........................................................................................................1-3

    1.3 Applications ...............................................................................................................1-3

    Basic Bridging .........................................................................................................1-3

    Routing Between Central and Remote Offices .........................................................1-3

    Dual Link Applications .............................................................................................1-4

    1.4 Physical Description ...................................................................................................1-5

    LEDs .......................................................................................................................1-5

    Connectors .............................................................................................................1-5

    Jumpers ..................................................................................................................1-5

    1.5 Functional Description ................................................................................................1-6

    Management ..........................................................................................................1-6

    Configuration Parameters .......................................................................................1-6

    1.6 Technical Specifications..............................................................................................1-6

    Chapter 2 Installation and Setup

    2.1 Installation .................................................................................................................2-1

    Rear Panel ..............................................................................................................2-1

    Internal Settings .....................................................................................................2-2

    Module Installation .................................................................................................2-3

    Cable Connections ..................................................................................................2-4

    Control Connector ..............................................................................................2-4

    2.2 Operating Indications .................................................................................................2-4

    Normal Indications ..................................................................................................2-4

    2.3 Initial Setup ...............................................................................................................2-5

    Connecting to the Terminal .....................................................................................2-5

    Setting a Password .................................................................................................2-5

    Changing and Deleting the Password ......................................................................2-6

    Chapter 3 Operation

    3.1 KMBE General Configuration .......................................................................................3-1

    3.2

    KMBE Bridge or Router Configuration .........................................................................3-2Configuring KMBE as a Bridge ..................................................................................3-2

    Configuring KMBE as a Router .................................................................................3-3

    3.3 Menus and Screens ....................................................................................................3-3

    The Main Menu .......................................................................................................3-3

    Quick Setup ............................................................................................................3-3

    Security Setup ........................................................................................................3-3

    Advanced Menu ......................................................................................................3-3

    View .......................................................................................................................3-3

    Diagnostic Tools .....................................................................................................3-3

    Exit .........................................................................................................................3-3

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    24/104

    Table of Contents Installation and Operation Manual

    ii KMBE

    Chapter 4 Configuration

    4.1 Quick Setup Menu ......................................................................................................4-1

    Principles of Operation ...........................................................................................4-1

    Quick Setup Example ...............................................................................................4-1

    Link Mode ..........................................................................................................4-1

    Routing ..............................................................................................................4-2

    WAN IP Address .................................................................................................4-2

    Host IP Setup .....................................................................................................4-2

    Security Setup ....................................................................................................4-3

    4.2 Security Setup ............................................................................................................4-3

    Enabling Telnet Access ............................................................................................4-4

    Enabling SNMP Access .............................................................................................4-5

    Enabling/Disabling the Solid Firewall ........................................................................4-54.3 Advanced Setup .........................................................................................................4-6

    Setup Menu ............................................................................................................4-7

    Host Parameters ................................................................................................4-7

    Routing/Bridging Menu .....................................................................................4-11

    Interface Parameters ........................................................................................4-20

    Access Control (Security) ..................................................................................4-26

    WAN Economy Menu ........................................................................................4-28

    Factory Default Options ...................................................................................4-36

    Device Control Menu .............................................................................................4-36

    Software Download ..........................................................................................4-37

    Device Configuration Parameters Upload/Download ..........................................4-39

    Reset Options ..................................................................................................4-40

    Control Other Device ........................................................................................4-40

    Terminal Type ..................................................................................................4-40

    Chapter 5 Troubleshooting and Diagnostics

    5.1 Error Messages ..........................................................................................................5-1

    5.2

    Technical Support ......................................................................................................5-2

    Appendix A Boot Manager

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    25/104

    KMBE Kilomux-2100/2104 Features 1-1

    Chapter 1

    Introduction

    1.1

    Overview

    KMBE is based on the MBE family of standalone bridges and IP/IPX routers for the

    small office. KMBE is a Kilomux-2100/2104 I/O module that can be used for

    various bridging and routing functions, connecting one or two Ethernet LANs via

    the Kilomuxs main links. Quick setup and advanced configuration menus provide

    on-screen instructions that guide you through the configuration procedures.

    Versions

    You can order KMBE with the following LAN interfaces:

    AUI

    Thin coax

    UTP (10BaseT).

    1.2

    Features

    The KMBE module has the following principle features:

    Routing

    Bridging

    IP, IPX, and IP+IPX Routing

    Single IP Address Translation

    Supports static nets and multi-nets

    Supports IP fragmentation

    Configuration and Control

    Supports Telnet allowing configuration and control of the device over WAN

    and LAN

    An SNMP agent provides management by RADview or any other standard

    SNMP management station

    Fast configuration from a terminal emulator and via Telnet or SNMP

    management

    Dual image Flash enables downloading two software versions

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    26/104

    Chapter 1 Introduction Installation and Operation Manual

    1-2 Features KMBE Kilomux-2100/2104

    Software downloading is available by TFTP

    Security

    Solid firewall protection

    PAP/CHAP authentication

    Undesired access to KMBE via Telnet or SNMP can also be blocked orpassword protected

    Other

    Supports PPP Protocol

    Supports 10Base2, 10Base5, or 10BaseT LAN interface

    Supports dual link applications

    Hot-swappable plug-in module.

    Bridging

    KMBE supports standard proprietary functionality. Because bridging is the KMBE

    default, you can use KMBE as a bridge with little or no configuration.

    IP Routing

    KMBE is an IP router that supports:

    Static IP net configuration

    Dynamic IP net learning using the RIP and RIP-2 protocols

    CIDR topologies

    Multiple IP nets on the LAN or WAN interfaces

    Numbered and unnumbered I/F

    IP fragmentation.

    IPX Routing

    In addition to IP routing, KMBE also supports IPX routing and includes support for

    RIP and SAP.

    Address Translation (Single IP) and FirewallKMBE includes a feature called Single IP. Single IP, designed by RAD, translates IP

    addresses. Single IP can be enabled or disabled. When enabled, KMBE allows

    users in a Small Office to connect to the Intranet quickly and transparently.

    Connection is via a synchronous link. Single IP also protects all Small Office users

    from hackers on the Intranet.

    Normally, a LAN requires a complete statically assigned, unique and legal subnet

    in order to connect to the Intranet. Single IP allows an entire Small Office to

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    27/104

    Installation and Operation Manual Chapter 1 Introduction

    KMBE Kilomux-2100/2104 Applications 1-3

    connect to the Corporate Intranet using only one dynamically or statically

    assigned IP address.

    Solid Firewall

    The Solid Firewall feature prevents access from the Intranet into the Small Office

    LAN. This feature makes the Small Office LAN invisible to outside users. The Solid

    Firewall feature is a simple and foolproof way of protecting security sensitive

    Small Offices (e.g. doctors and lawyers) from Intranet hackers.

    1.3

    Applications

    This section gives four examples of the applications KMBE can be used in.

    Basic Bridging

    Two KMBEs can be used opposite each other in a bridging application. The KMBE

    connected to the larger network or to a network with connections to other

    networks, is the Main KMBE. The KMBE connected to the smaller network is the

    Remote KMBE, see Figure 1-1.

    Figure 1-1. Bridging Application

    Routing Between Central and Remote Offices

    You can use the KMBE as a router to connect a central office to a remote office.

    This application allows you to:

    Use data compression

    Setup firewall protection

    Supply Internet access to all of the remote offices through only one Internetconnection.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    28/104

    Chapter 1 Introduction Installation and Operation Manual

    1-4 Applications KMBE Kilomux-2100/2104

    Figure 1-2. Routing Application with IP+IPX Data Compression

    Figure 1-3. Routing Application with a Firewall

    Dual Link Applications

    In a dual link application, KMBE can work with both Kilomux main links

    simultaneously, connecting two remote LANs to a central LAN and therefore

    provides a cost-effective and simple solution for corporate applications. KMBE

    can also operate opposite another KMBE module, see Figure 1-4.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    29/104

    Installation and Operation Manual Chapter 1 Introduction

    KMBE Kilomux-2100/2104 Physical Description 1-5

    Figure 1-4. Dual Link Application for KMBE

    1.4

    Physical Description

    KMBE modules are designed for installation in any I/O slot of a Kilomux-2100 or

    Kilomux-2104 chassis. Installation procedures for KMBE are provided in Chapter 2

    of the Installation and Operation Manual.

    LEDs

    The LED indicators on the rear panel show the operating status of KMBE. Various

    indicators display LAN activity, configuration mode, alert conditions, and

    readiness of the system. For a description of the rear panel, see Rear Panel

    section in Chapter 2.

    Connectors

    The LAN connector, located on the rear panel, is available in different interfaces

    according to your needs.

    Jumpers

    You need to set the internal jumpers of KMBE according to the specific conditions

    of use. For more information on setting the jumpers, see Internal Settings section

    in Chapter 2.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    30/104

    Chapter 1 Introduction Installation and Operation Manual

    1-6 Technical Specifications KMBE Kilomux-2100/2104

    1.5

    Functional Description

    You can configure KMBE to function as a bridge or router.

    Management

    An SNMP agent provides management by RADview or any other standard SNMP

    management station. For more information, see SNMP Manager Tablein Chapter 6.

    Configuration Parameters

    KMBE supports Telnet, allowing configuration and control of the device over WAN

    and LAN. You can also perform fast configuration from a terminal emulator. For

    more information, see Initial Setupin Chapter 3.

    1.6

    Technical Specifications

    L N Interface Standard Conforms to Ethernet/IEEE 802.3

    Type 10Base2 with coax connector

    10BaseT with RJ-45 connector

    AUI with 15-pin, D-type female

    Control Port Interface RS-232/V.24

    Connector RJ-45

    Data Rates 1.2 to 9.6 kbps

    Data Format 8 bit, no parity

    General Bandwidth Allocated on

    Kilomux Main Link

    9.6 to 1280 kbps

    Data Buffer Size 256 kb

    Protocol HDLC based

    Panel Control Reset

    Diagnostics Local module loopback

    Remote module loopback

    Internal BER test

    Auto self-test

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    31/104

    Installation and Operation Manual Chapter 1 Introduction

    KMBE Kilomux-2100/2104 Technical Specifications 1-7

    Indicators LAN ERR (red)

    Lights momentarily when an error is

    detected on the LAN interface

    LINK ERR (red) (Per Link A&B)

    Flashes when the relevant main link between

    the local and remote KMBE/N is disconnected

    Lights momentarily when an error is detected

    on a packet received from the relevant link

    LAN TX (yellow)

    Lights momentarily when packets are

    transmitted toward the LAN

    LAN RX (yellow)

    Lights momentarily when packets are

    received from the LAN

    READY (green)

    Lights when KMBE/N is ready to forwardpackets

    Flashes when KMBEs are synchronized but no

    workstation has requested

    MAIN (green)

    Lights when KMBE/N is configured for

    connection to the main LAN

    REM (green)

    Lights when the KMBE/N is configured for

    connection to the remote LAN

    UTP (green)Lights when 10BaseT interface is connected

    to the LAN (on modules with UTP interface

    only)

    Power

    Consumption

    1.1W

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    32/104

    Chapter 1 Introduction Installation and Operation Manual

    1-8 Technical Specifications KMBE Kilomux-2100/2104

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    33/104

    KMBE Kilomux-2100/2104 Installation 2-1

    Chapter 2

    Installation and Setup

    This chapter provides information on the functions of the rear panel indicators

    and connectors of the KMBE module, and instructions for performing the internal

    settings, physical installation, and cable connections to this module.

    The KMBE module contains components sensitive to electrostatic discharge (ESD).

    To prevent ESD damage, always hold the module by its sides, and do not touch

    the module components or connectors.

    2.1 Installation

    Rear Panel

    The rear panels of the three models of KMBE modules are shown in Figure 2-1.

    The module rear panel includes several indicators, a RESET push-button and the

    LAN connector. Their functions are explained in Table 2-1.

    2

    REMMAIN

    8

    5 6

    7

    U

    A

    10

    KMBE

    3

    4LAN

    RESET1 1

    4

    3

    10

    7

    65

    8

    MAIN RE M

    2

    THIN

    COAXUTP

    2

    ERR

    REMMAIN

    8

    5 6

    7

    10

    3

    4

    TX

    1

    12

    I

    9 9 9

    11 11 11

    KMBE KMBE

    ERRERR

    LAN LAN

    TXTX RX RXRX

    RESETRESET

    C

    T

    R

    L

    C

    T

    R

    L

    C

    T

    R

    L

    RDY

    LI NK A L IN K B

    LAN

    ERRRDY

    L IN K A LI NK B

    LAN

    ERRRDY

    LI NK A L IN K B

    LAN

    ERR

    Figure 2-1. KMBE Rear Panel Versions

    Caution

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    34/104

    Chapter 2 Installation and Setup Installation and Operation Manual

    2-2 Installation KMBE Kilomux-2100/2104

    Table 2-1. KMBE Module, Functions of Rear Panel Components

    Item Indicator Function

    1 RESET push-button Resets the KMBE module, and starts the initialization process

    2 READY Indicator (green) Lights steadily when the KMBE module is ready to forward packets

    3 LAN TX Indicator (yellow) Lights to indicate that packets are transmitted to the LAN

    4 ERR LINK A Indicator (red) Lights steadily when the link between the local and remote KMBE

    modules is disconnected

    Lights momentarily for each error detected in a packet received

    from link A

    5 MAIN Indicator (green) Lights to indicate that the KMBE module is configured for operation

    in the local mode

    6 REM Indicator (green) Lights to indicate that the KMBE module is configured for operation

    in the remote mode

    7 ERR LINK B Indicator (red) Lights steadily when the link between the local and remote KMBE

    modules is disconnected

    Lights momentarily for each error detected in a packet received

    from link B

    8 LAN RX Indicator (yellow) Lights to indicate that packets are received from the LAN

    9 LAN ERR Indicator (red) Lights momentarily during connection to the LAN

    Lights steadily if connection to the LAN failed

    10 CONTROL connector RJ-45 connector, used for connection of an optional ASCII terminal

    used for KMBE configuration, monitoring and diagnostics

    11 LAN Connector Connection to the local LAN

    Connector type depends on the KMBE module model

    12 LAN Connection Indicator

    (green only for UTP)

    Lights when the KMBE UTP interface is connected to the local LAN

    Internal Settings

    All KMBE modules have one user-selectable jumper, designated WTCH-DOG. The

    KMBE modules include additional jumpers, which are factory-set and should not

    be moved. The WTCH-DOG jumper allows maintenance personnel to disable the

    KMBE watchdog circuit during maintenance.

    Figure 2-2shows the location of the jumper. The jumper has two positions: ON - The watchdog circuit is enabled. This is the setting required for normal

    operation

    OFF - The watchdog circuit is disabled.

    The default setting is ON.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    35/104

    Installation and Operation Manual Chapter 2 Installation and Setup

    KMBE Kilomux-2100/2104 Installation 2-3

    ON

    OFF

    ON

    OFF

    WTCH-DOG

    JP6

    JUMPER-JP6

    WATCHDOG

    ENABLED

    DISABLED

    WATCHDOG

    FUSE F1

    FUSE F3 FUSE F2

    WTCH- DOG

    STN-HUB SWITCH(UTP INTERFACE ONLY)

    STN

    HUB

    FOR KMBE CONNECTED

    DIRECTLY TO LAN

    TO HUB

    FOR KMBE CONNECTED

    STN

    HUB

    Figure 2-2. Module KMBE, Internal Settings

    KMBE modules with thin Ethernet and AUI interfaces do not have additionaljumpers, as all of their remaining functions are programmable. The KMBE module

    with UTP interface, however, has one additional switch, designated STN/HUB,

    located on the LAN interface card. Figure 2-2also identifies the location of this

    switch. The switch is located on the printed circuit side of the module.

    The STN/HUB switch controls the connection of the internal transmit and receive

    pairs to the external UTP pairs to allow direct connection, without cross cables.

    Table 2-2shows the switch settings.

    Table 2-2. STN/HUB Switch Settings

    Switch Setting Receive Transmit

    STN (Station) Pins 1, 2 Pins 3, 6

    HUB Pins 3, 6 Pins 1, 2

    The correct position of the switch depends on the wiring used in your particular

    network. In general:

    Set the switch to STN if the KMBE module connects directly to the LAN (thisinterchanges the connections of the receive and transmit pairs).

    Set the switch to HUB if the KMBE module connects to an Ethernet hub.

    Factory setting is HUB.

    Module Installation

    The KMBE module can be inserted into, or removed from, an operating chassis

    (hot-swappable).

    Refer to the system installation plan and insert the module in the assigned I/O

    slot of the Kilomux chassis.

    The module is ready to start operating as soon as it is plugged into an operating

    Kilomux chassis. For module configuration instructions, see Chapter 3.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    36/104

    Chapter 2 Installation and Setup Installation and Operation Manual

    2-4 Operating Indications KMBE Kilomux-2100/2104

    Cable Connections

    Identify the cable intended for connection to the LAN connector of this module,

    and connect the cable to the module connector on the rear panel.

    For the KMBE module with UTP interface, verify that the LAN receive and transmit

    pairs are properly connected in accordance with the wiring conventions used in

    your system.

    Control Connector

    The CONTROL connector is an RJ-45 connector wired as follows:

    Table 2-3. Control Connector Pinout

    Pin esignation irection Function

    1, 2 Internal Test Reserved

    3 Not Connected

    4 SG Signal Ground

    5 TXD OUT Transmit Data

    6 RXD IN Receive Data

    7 Not Connected

    8 Not Connected

    Do not make connections to pins 1 and 2.

    2.2 Operating Indications

    Normal Indications

    After the power-up self-test, either the MAIN or the REM indicator must light,

    indicating the selected mode. The LAN RX and LAN TX indicators must light (or

    flash), and the ERR LAN and ERR LINK indicators must be off.

    The READY indicator will turn on when the LAN and WAN interfaces are ready.

    If a links synchronization is lost, the KMBE modules will attempt to re-establish

    the link automatically. If the attempt does not succeed, the KMBE modules reset

    themselves, and continue the attempts to resynchronize. During these attempts,

    the LINK ERR indicator flashes slowly.

    Note

    Note

    Note

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    37/104

    Installation and Operation Manual Chapter 2 Installation and Setup

    KMBE Kilomux-2100/2104 Initial Setup 2-5

    2.3 Initial Setup

    KMBE features a setup program that is invoked and run from an ASCII terminal or

    a PC terminal emulator. The terminal/terminal-emulator is connected to the

    CONTROL port on the KMBE rear panel.

    This section describes how to connect to the terminal and to access the Mainmenu setup program.

    Connecting to the Terminal

    To connect the terminal:

    1. Connect a control cable between the KMBE RJ-45 CONTROL port and the

    connector on the terminal; or between the KMBE RJ-45 CONTROL port and

    the PC communication port (refer to Figure 2-3).

    2. Set the terminal to work at any Baud rate from 2.4 to 19.2 kbps, No Parity, 8

    Data Bits. The Baud rate is self-adaptable.

    3. Set the hardware control to OFF.

    4. Switch on KMBE. The operational status screen displays. Press

    several times to invoke the password message.

    Figure 2-3. Connecting to the Terminal

    Setting a Password

    For first time operation, or if no configuration password has been specified, the

    following message appears:

    WARNING: No configuration password exists.

    Define configuration password? (Y/N):

    To set a password:

    1. Type Yto set a configuration password.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    38/104

    Chapter 2 Installation and Setup Installation and Operation Manual

    2-6 Initial Setup KMBE Kilomux-2100/2104

    A message appears, prompting you to enter a new configuration

    password.

    2. Type a password.

    The password can be up to twelve characters.

    3. Press ENTER.

    A message appears, prompting you to retype the password forverification.

    4. Retype the password and press ENTER.

    The Main menu screen appears.

    The password protects entry to the configuration module, preventing

    unauthorized personnel from changing setup and configuration parameters.

    All KMBE password verification routines are CASE SENSITIVE. Once a password has

    been set, always use the same case when typing the password.

    Changing and Deleting the Password

    To change the password during normal operation:

    1. From the Main menu, select option 0, Exit, to return to the Operational Status

    Messages screen.

    2. Press ENTERseveral times.

    3. Enter the current password.

    A message appears, asking if you want to update the current password.

    4. Type Y You will be prompted to retype the current password.

    5. Retype the current password.

    A message appears prompting you to enter the new password.

    6. Type the newpassword and retype the same password for verification.

    The Main menu appears.

    To delete the current password:

    Follow steps 1-5 above to change the password.

    1. When prompted to enter a new password, press ENTERwithout typing a new

    password.

    This deletes the current password and removes password protection.

    2. Press ENTERagain when prompted for verification.

    The Main menu appears. If the unit doesn't have an IP Address, the Quick

    Setup menu appears.

    Use of Password protection for the configuration module is recommended.

    Always use the Exit option in the Main menu once the unit has been

    configured. Using the Exit option will force personnel requiring access to the

    configuration module to use a password.

    Note

    Note

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    39/104

    KMBE Kilomux-2100/2104 KMBE General Configuration 3-1

    Chapter 3

    Operation

    This chapter gives an introduction on how to operate and initially configure

    KMBE. Topics covered in this chapter include:

    Composite Channel Configuration

    Configuring KMBE as a bridge or router

    Menus and Screens.

    3.1

    KMBE General ConfigurationYou can configure KMBE via the Kilomux supervision port using an ASCII Terminal

    or any supported remote management. You can also configure Channel

    parameters (Link Speed and Location) from the LCD on the Kilomux front panel.

    For information about these configuration methods, refer to the

    Kilomux-2100/2104 System Installation and Operation Manual. Table 3-1explains

    the KMBE composite channel configuration parameters.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    40/104

    Chapter 3 Operation Installation and Operation Manual

    3-2 KMBE General Configuration KMBE Kilomux-2100/2104

    Table 3-1. KMBE Composite Channel Configuration Parameters

    Parameter Function Values

    LOCATION Selects the location of the KMBE

    module.

    This parameter can only be

    configured via the CL module by

    the command DEF CH i, where i

    is the slot number from 1 to 12.

    MAIN

    connects KMBE to the main LAN

    REM

    connects KMBE to the remote LAN

    Default MAIN

    LINK_SPEED Selects the link bandwidth

    assigned to the KMBE module

    This is an external port parameter,

    also configurable from the

    Kilomux LCD

    NC

    Module not connected

    9.6, 19.2, 28.8

    38.4, 48.0, 57.6

    67.2, 76.8, 86.4

    96, 105.6, 115.2

    124.8, 128, 160

    192, 224, 240

    272, 304, 336,

    368, 512, 768,

    1024, 1536 Composite channel data

    rate, in kbps.

    Default NC

    Note

    Table 3-2specifies the

    comptiablity of the various KMBE link

    bandwidth with the Kilomux main link

    rates.

    LINK Selects to which Kilomux link each

    KMBE module connectsThis is a DEF CON command

    parameter

    ML-A

    ML-B

    BOTH

    All fields When both external channels are

    connected the slot is configured

    for two lines, one for Main Link A,

    and one for Main Link B

    This is a DEF FRAME command

    parameter

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    41/104

    Installation and Operation Manual Chapter 3 Operation

    KMBE Kilomux-2100/2104 KMBE General Configuration 3-3

    Table 3-2. KMBE Link Bandwidth Compatibility with the Kilomux Main Link Rate

    Main Link Rate

    Link Bandwidth

    384 512 768 1024 1536

    9.6 + + +

    19.2 + + + + +

    28.8 + + +

    38.4 + + + + +

    48.0 + + +

    57.6 + + + + +

    67.2 + + + + +

    76.8 + + + + +

    86.4 + + +

    96 + + + + +

    105.6 + + +

    115.2 + + + + +

    124.8 +

    128 + + + + +

    160 + + + + +

    192 + + + + +

    224 + + + + +

    240 + + +

    272 + + +

    304 + + +

    336 + + +

    368 + + +

    512 + + +

    768 + +

    1024 +

    1280 +

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    42/104

    Chapter 3 Operation Installation and Operation Manual

    3-4 Menus and Screens KMBE Kilomux-2100/2104

    3.2

    KMBE Bridge or Router Configuration

    KMBE can be configured as either a bridge or a router. KMBE, by default is

    automatically configured in the bridge mode. Decide whether KMBE will be used

    as a bridge or a router before you start the configuration.

    Configuring KMBE as a Bridge

    By default, KMBE is automatically configured in bridge mode. Before you

    configure KMBE as a bridge, set the location parameter to Remote or Main. One

    of the two KMBEs in the bridge must have the location parameter set to Remote

    and the other set to Main:

    Remote- If the KMBE you are configuring as a bridge is connected to the

    network that is smaller, and has no connections via a router to other

    networks

    Main- If the KMBE you are configuring as a bridge is connected to the

    network that is larger or has connections via a router to other networks.

    Configuring KMBE as a Router

    You can use KMBE as a router with compression capability to separate networks.

    Before configuring KMBE as a router, set the location switch to Main.

    3.3 Menus and Screens

    This section provides a brief description of the available KMBE menus andscreens.

    The Main Menu

    The name of the device (KMBE) connected to the terminal is listed at the top of

    the screen. The Main menu has five options. To choose an option, type the

    number preceding the option.

    MAIN MENU ( Device name KMBE )

    1. Quick setup

    2. Security setup

    3. Advanced setup

    4. View

    5. Diagnostic tools

    0. Exit

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    43/104

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    44/104

    Chapter 3 Operation Installation and Operation Manual

    3-6 Menus and Screens KMBE Kilomux-2100/2104

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    45/104

    KMBE Kilomux-2100/2104 Quick Setup Menu 4-1

    Chapter 4

    Configuration

    4.1

    Quick Setup Menu

    The Quick Setup menu allows you to enter the minimum number of parameters

    needed to operate your KMBE/N.

    Principles of Operation

    The Quick Setup screen guides you through the configuration, port by port. The

    Quick Setup screen asks you for the appropriate parameters depending on the

    type of port you are configuring and how you have already configured otherports. The Quick Setup screen presents messages, and prompts you to accept or

    modify the current parameters.

    To accept the current parameter, press ENTER

    The parameter options are enclosed in brackets [ ]. To view the options, usethe space bar to toggle, then press ENTER

    To enter new information, type in the new parameters and press ENTER.

    After all parameters have been accepted or changed, you can view them on the

    screen. A confirmation message appears requesting that you confirm all the

    setup changes. The device resets after the changes are saved.

    To configure the setup parameters:

    1. From the Main menu, select option 1, Quick Setup.

    2. Follow the on-screen instructions to accept or modify the setup parameters.

    3. Press Yto save the setup parameters.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    46/104

    Chapter 4 Configuration Installation and Operation Manual

    4-2 Quick Setup Menu KMBE Kilomux-2100/2104

    Quick Setup Example

    QUICK SETUP

    -----------

    WARNING: This device automatically exits to OperationalMessages

    10 minutes after last keyboard action without savingparameters

    'ENTER' - Accept parameter , 'SPACE' - Change parameter .

    WAN interface #1 - V.11

    Connection type: [Uplink ]

    Link mode: [Synchronous ]

    Routing: [BRIDGE ], Protocol: [PROPRIETARY]

    Connection : [Always ]

    LAN IP address : 192.168.1.2 , enter new : 192.168.1.3

    LAN IP mask : 255.255.255.000 , enter new :255.255.255.000

    Default gateway setting by: [Interface ]

    Default gateway interface: 1

    SECURITY setupDevice access name : KMBE/N

    No password at present - do you want to createpassword(Y/N)?:[N]

    Security type: [Disabled]

    Saving the changes might cause RESET the unit.

    Do you want to save QUICK SETUP (Y/N) ? Y

    The fields in the Quick Setup example are described below:

    Link Mode

    Select this parameter to determine how data is transmitted across the link. When

    the mode is synchronous, data bits are transmitted at a fixed rate. The sender

    and the receiver are synchronized. The other mode is Frame Relay. Frame Relay is

    a packet-switching protocol for connecting devices on a WAN.

    Use the space bar to toggle between Synchronous, or Frame Relaymodes.

    Routing

    Select this parameter to assign the link type. Use the space bar to toggle

    between Bridge, IP, IPXor IP IPXlink types.

    Selecting IPX link type disables the Single IP and WAN IP Address features, andremoves the corresponding parameters from the screen.

    WAN IP Address

    Select this parameter to enter the IP address for the WAN interface.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    47/104

    Installation and Operation Manual Chapter 4 Configuration

    KMBE Kilomux-2100/2104 Quick Setup Menu 4-3

    Host IP Setup

    LAN IP Address

    Select this parameter to enter the IP address. Every device on a TCP/IP network

    must have an address to identify it. The IP address is a value consisting of the

    network address and the host address on that network. The value assigned to a

    network depends on the number of computers on that network.

    The IP address is a 32-bit number. The number is made up of 4 parts, with each

    part consisting of 3 digits. One part of the address identifies the network and

    another part of the address identifies the host. Which numbers in the address

    identifies the host is dependent on the IP class.

    There are 5 classes of IP addresses. Each class represents a network having a

    certain number of computers. For example, a Class C address is given to a

    network having between 1-255 computers. Table 4-1gives the ranges for

    different classes of IP addresses.

    Table 4-1. IP Classes

    Class Range

    A 0.0.0.0 to 127.255.255.255

    B 128.0.0.0 to 191.255.255.255

    C 192.0.0.0 to 223.255.255.255

    D 224.0.0.0 to 239.255.255.255

    E 240.0.0.0 to 247.255.255.255

    The numbers in each part of the code are translated into binary. The binary code

    identifies the network and the host.

    IP addresses are assigned by the Internet Network Information Center (InterNIC).

    InterNIC assigns the network ID. Host IDs are assigned by the network

    administrator.

    LAN IP Mask

    Select this parameter to enter the IP mask. The mask is configured automatically

    from the IP address class, as shown in Figure 4-1. If you want to change the

    default mask, enter a new mask. For example, the IP mask is usually

    225.225.225.0. A mask of this sort would allow 254 hosts on the LAN. If you

    want to create a subnet which allows 6 users, including KMBE/N, configure the

    mask as 22.225.225.248. on KMBE/N and each host that is included on the

    subnet.

  • 7/24/2019 Manual KMBE Kilomux 2100-2104

    48/104

    Chapter 4 Configuration Installation and Operation Manual

    4-4 Security Setup KMBE Kilomux-2100/2104

    KILOMUX

    IP addressMaskDefault Gateway

    192.168.1.2255.255.255.248192.168.1.1

    .3.248

    192.168.1.1

    .4.248

    192.168.1.1

    .5.248

    192.168.1.1

    .6.248

    192.168.1.1

    LAN IP address 192.168.1.1

    Mask 255.255.255.248

    DigitalNetwork

    KMBE/N

    Figure 4-1. Setting up the IP Mask

    Security Setup

    Device Access Name

    Select this parameter to display the name assigned to KMBE/N for identificat