Automated Hematology AnalyzerMEK-7222J/K
22 parameters with WBC 5 part differential
User-friendly Operation with a Compact Body
Shown with optional built-in printer
The best choice for your lab
User friendly operation Compact High accuracy and reliability Low reagent consumption Optional network and
Data management expandability
WBC 5 part differential with advanced laser technology provides reliable data at low cost
22 parameters WBC RBC NE% HGB LY% HCT MO% MCV EO% MCH BA% MCHC NE RDW LY PLT MO PCT EO MPV BA PDW
2 11
Only 3 steps to get a result
Step 1. Press the power keyPrimingisautomaticanditisreadyforusewithin
oneminute.
Step 2. Bring the sample to the nozzleBringawholebloodsampletothesamplingnozzle.
Step 3. Press the count switchAspirationandcountingstart.
Allnumericdata,histogramsandscattergramsare
shownonabacklitLCDdisplay.Thedisplayhas
touchscreenoperationforeasyeditingofmeasured
data.Dataisautomaticallyprintedonanoptional
built-inprinterorexternalprinter.
CelltacEprovidescompleteWBC5partdifferential
andCBCmeasurementwithoutaPC.This
contributestoeasyoperationforstaffwhoarenot
frequentoperatorssuchasoff-peakshiftintheER
orICU.CelltacEscompactsize(only380mmwidth
and485mmdepth,notincludingreagentbottles)
alsosavesdesktopspace.
Celltac innovation in hematology analyzers since 1972
3 10
Simple operation and compact design
Standalone design
CBC or CBC + WBC 5 part diffYoucanselectonlythenecessarymeasurement
CBConly,orCBC+WBC5partdifferential.This
helpseliminateunnecessaryreagentconsumption.
Open and closed sample measurementCelltacEhasauniquedesigncappierceunit(option).
Itcanbeusedforclosedaswellasopensample
measurement.
Variety of measuring modes
(Screenshown:CelltacE)
Openmode Closedmode
High accuracy and reliability
&
Technologies for reliable data
Patented laser technologyAninnovative3anglelaserscatterdetectorprovides
betterdetectionofscatteredlightfromtheWBC
cell.FromasmallforwardangleitobtainsWBC
sizeinformation,fromalargeforwardangleit
obtainsinformationofcellstructureandcomplexity
ofnucleo-chromatinparticles,andfromaside
angleitobtainsinternalgranularityandglobularity
information.This3Dgraphicinformationiscalculated
byaspecialNihonKohdensoftwarealgorithmand
superiorclassificationofWBC5partdiffpopulation
isdisplayedonthescreen.
No chemical processing of WBCThepatentedleukocyteclassificationreagent
selectivelyhemolyzestheredbloodcellswhile
leavingthewhitebloodcellsintact.Thenucleus,
granulesandcellularityremainintactsoCelltacE
andCelltacFcangetinformationfromnatural
shapedWBCnucleiandgranulesandperformmore
accurateWBC5diffmeasurement.
Optimal flow channelsAconsistentaspirationvolumeofdilutedsampleismaintainedbyamanometerforstableandaccurateCBC
measurement.TheshortfluidpathsofCelltacEandCelltacFallowutilizationoftheentiresamplewithout
waste.ANihonKohdenpatenteddoublemixingchamber,twinsampleneedleandsamplingnozzlecleaning
holderminimizecontaminationandallowhighaccuracyandhighreproducibilitymeasurement.
4 9
Size
Granularity
Size
Granularity
Size
Complexity
MO BA
Size
Granularity Complexity
NE
EO
NEEO
MO
BA
LY
Useful flag messages
Flag messages Thefollowingmessagescanbedisplayedor
printedwhenthemeasurementresultisoutof
range.
*Leukocytosis *Erythrocytosis
*Leukopenia *Anemia
*Neutrophilia *Anisocytosis
*Neutropenia *Microcytosis
*Lymphocytosis *Macrocytosis
*Lymphopenic *Hypochromia
*Monocytosis *AbnormalMCHC
*Eosinophilia *Thrombocytosis
*Basophilia *Thrombocytopenia
*Blasts *PLTClumps
*ImmatureGr *PLTRBCInterference
*LeftShift *IfCappearsonthe
*AtypicalLymphocytes rightwidthofthe
*SmallNucleatedCell WBCorPLTdata,
*Ly-MoInterference thePLTmaybe
*Ne-MoInterference coagulated.
Celltac innovation in hematology analyzers since 1972
ALL: Acute Lymphoblastic Leukemia (L2) CLL: Chronic Lymphocytic Leukemia
WBC 5.1 X 103/mLLC% 64.4%LC# 3284/mLFlags LMI
SNC
WBC 16.5 X 103/mLLC% 90.7%LC# 14966/mLFlags SNC
Size
Complexity Granularity Granularity
Size
Size
Size
Complexity Granularity Granularity
Size
Size
New flags and improved measurement[LMI]Ly-MoInterfaceisdisplayedintheflagdisplayarea.
[NEI]Ne-EoInterferenceisdisplayedintheflagdisplayareaand*marksaftera#NE,%NE,#EO,or%EOvalueindicateinvaliddata.
[PRI]PLT-RBCInterferenceisdisplayedintheflagdisplayareaand*marksafteraRBCorPLTvalueindicateinvaliddata.
[SNC]SmallNucleatedCellisdisplayedintheflagdisplayarea,and*marksafteraWBCvalueindicateinvaliddata.
5 8
Plus
Data Management Expandability
Data Management Software(DMSPro,QP-822V)(option)
Additional research parametersTheDMSProsoftwaregivesresearchparametersof
ImG(ImmatureGranulocyte),ImG%,Band,Band%,
SEGandSEG%.
Data view functionYoucancompareandchoosedatawiththe
thumbnailscattergramlist.
Customizable print formatYoucanenterinputmanualcountdatafromthePC
keyboardandaddthecolumntotheprintedresults.
YoucanalsoaddimagesfromthePC.
Editing print layout
QC management
6 7
Youcaneasilyedittheprintlayoutwiththemouse.
Plus
&
Data Management Expandability
CelltacEandCelltacFcanbeusedaloneorwithaPC.
IfyouconnectittoaPCwithoptionalDataManagement
Software,datacanbestoredonaserver.CelltacFcanalso
beconnectedtoanLISandHISnetworksysteminyou
laboratory.
Network expandability
Display and printing acquired data
on a PCTransferreddatacanbedisplayedona
spreadsheetinthePC.Alldisplayeddata
includedcolorscattergramsandhistograms
canbeprintedonacolorprinter.
Bar code label printing Barcodelabelsfortheworklistcanbe
printedontheoptionalthermalprinter.
Connection to LIS and HIS networkThePCcanbeusedasagatewaytoa
LaboratoryInformationSystemorHospital
InformationSystem.
Large data storageNumericaldata,scattergramsand
histogramsforeachmeasurementcanbe
savedonaPCandreadanytime.Data
canbesavedonCD-Rorothermediafor
virtuallyunlimitedstorage.
160 sample throughput and low
cost backupADPC-Celltac(DualProcessControlled
Celltac)systemcancontroldualCelltacF
analyzers.Thisincreasesthroughputto160
samplesperhourandcanbeusedasalow
costbackupsystemforyourlab.
Celltac innovation in hematology analyzers since 1972
7 6
LISorHIS
Barcodeexample
or
LAN
Host(LIS)
CelltacFLaserprinter
DMS(PC+QP-822V)
Thermalprinter
CelltacF CelltacE
Impactprinter Barcodereader
DMS(PC+QP-822V)
CelltacF
Host(LIS)
Inputtheworklistfile
Createyouroriginalresultfile
Barcode
Worklist
Measureddata
Effective total cost management
Useful functions for reliability
WBC high dilution measurementWhenWBCishigh,noisyorhaspoor
hemolyzation,youcanremeasureitby
automaticallychangingthedilutionratio.
WBC expanded measuring rangeWBChighandhigherdilutionmodesallow
expansionofthemeasuringrange,Celltac
EandCelltacFcanmeasureWBCto599
103L.
Reagent management systemWhenareagentreachesthewarning
volume,awarningwindowisdisplayed.
Work list functionYoucanpresetpatientinformationsuchasID,physician
name,measuringparameters,andcommentsforsamples.
IfyouconnectaPCwithDataManagementSoftware(QP-
822V),youcanenterthepatientinformationonthePCand
sendittoaCelltacEandCelltacF.Aftermeasurementthe
datacanbesentbacktothePC.
CelltacE:Upto50worklistdatacanbeentered.
CelltacF:Upto500worklistdatacanbeentered.
Youcanchooseworklistmodewithorwithoutbarcode.
Useful QC management programsCelltacEandCelltacFprovide4QCprograms:Xbar-R,
Levey&Jennings,XbarBatchandXbarDayCVfor
qualitycontrol.Theseprogramsautomaticallycalculatethe
plottingdatafromthesampledata.
8 5
&
Time and cost saving
Low reagent consumptionANihonKohdenoriginalsyringepumpprecisely
aspiratesthelowsamplevolumeof28LforCBC
or55LforCBC+WBC5partdiff.Thesample
remainsinthesamplingneedlesoitdoesnotneed
tobesenttothesyringepump.Thisallowsashort
fluidpathforthebloodsample.Also,unlikeshared
valvemethodinstruments,thesyringedoesnotneed
toberinsedaftereverydispensing.Thesefeatures
contributetothesmallbloodsampleandlowreagent
consumptionof
NihonKohden
Celltacseries
hematology
analyzers.
Twin needle systemCelltacEandCelltacFhavetwinsampling
needlesfortwobathsfordifferentdilutionsof
WBCandHGB,andRBCandPLT.Thisprevents
countingerrorsfromcrosscontaminationof
dilutions.
Automatic electric clog removalTopreventingclogging,CelltacEandCelltacF
removebloodproteinanddustparticlesfrom
theaperturebyahighvoltageclogshattering
electricalpulseaftereachmeasurement.If
aclogoccurs,
theCelltacE
andCelltacF
automatically
removetheclog
andrecountthe
sample.
Fully automatic operationWhenthepoweristurnedon,thefluidpathis
automaticallyprimedandCelltacEandCelltac
Farereadytouseinminutes.Whenthepower
isturnedoff,thefluidpathisautomatically
cleaned.
Diluent
Syringepump
Doublemixingchamber
Celltac innovation in hematology analyzers since 1972
9 4
Unique and compact blood mixing
system NihonKohdenspatentedbloodmixingsystem
contributestothecompactsizeofCelltacF.The
sampleiseffectivelymixedinasmallspaceby
rotatingthetubeinsteadoftippingitendoverend.
Computercontrolleddirectionandrotationspeed
providesmoreeffectivebloodmixing.Theunique
bloodmixingmethodcreateshorizontalandvertical
whirlpoolsofbloodbyalternatingnormalrotationand
reverserotation.Also,therotationspeedisquickly
changedsothatbloodsamplesareevenlymixed
withnocelldamage.
The best choice for your lab
10 3
Simple and intuitive interface
One touch operation for getting a resultLargeandcoloredswitchesforroutineoperation
alloweasyoperationeveninemergencies.Thisis
usefulwhenhematologyspecialistsarenotavailable,
suchastheERatnight.
Clear display with touch screenCelltacFshowsclearclassificationofWBC5partdiff
onahighresolutioncolorTFTLCD.Measurement
conditionsettings,scattergramsdisplay,dataediting
andotheroperationisdonebyintuitivetouchscreen
operation.
High speed processing
80 samples/hour throughputInjust45seconds,CelltacFcanmeasureCBC
orCBC+WBC5partdiffforonesample.Itshigh
speedmeasurementof80samplesperhourwith
auto-samplersupportseasyandefficienthematology
testinginyourlab.Ontheworklist8or22parameter
measurementcanbesetforindividualsamplesin
therack.
STAT measurementCelltacFcaninterruptroutinesampleprocessing
toimmediatelymeasureemergencysamples.You
canloademergencysamplesintheSTATposition
onthesamplerackandpushtheEmergencykey
oryoucanmeasureandemergencysamplewith
themanualmode-nozzlewhileroutinesamplesare
beingmeasuredinautomode.
Automatic recountCelltacFautomaticallyrecountsthemeasuredsamplewhenanyofthefollowingoccurs:
Anyvalueoutsidetheuserdefinedrange
Alarmmessage
WBCoutsidethemeasurablerange
DilutionlevelforrecountingcanbesettoHIGHorHIGHER.
The Celltac F hematology analyzer with auto-sampler features high speed processing80 samples per hour throughputto support your effective lab operation
22 parameters WBC RBC NE% HGB LY% HCT MO% MCV EO% MCH BA% MCHC NE RDW LY PLT MO PCT EO MPV BA PDW
Celltac innovation in hematology analyzers since 1972
11 2
High speed processing with auto sampler Automatic recount High accuracy and reliability Effective total cost management Optional network and
Data management expandability
6388 CAT.No.55-083A 10 .05. SZ. B
PlusDMS
Automated Hematology AnalyzerMEK-8222J/K
22 parameters with WBC 5 part differential
Reliable, Cost-saving, and User-friendly
Printed in Japan on FSC certified paper