8/17/2019 Manual Chapa Electronica
1/9
8/17/2019 Manual Chapa Electronica
2/9
8/17/2019 Manual Chapa Electronica
3/9
en
14
Menu code changingChanging of administrator and user code
Menu languageChoice the language
Menu Key synchronise *In this program the channel of the E Key* will be
adjusted to the channel of the input unit. This is
necessary if the radio channel of the input unit has
to be changed although other E Keys* (with old
radio channel adjustment) are stored.
Menu InfoInforms about version and serial number.
Menu InfoInforms about version and serial number.
SNA Serial No of the lock
• User create Users, codes and E Keys* can be stored.
• E Key assign Specified users could be assigned to an
E Key later.
• Delete Users, codes and E Keys* can be
deleted
• Time entry Input of time and calibrating of the clock
The clock will be automatically calibrated
between two clock time adjustments.
Exception: Changing of batteries in the
meantime and change-over of summer
and winter time.
• Date entryInput of date
• RFID channel *12 different channels are selectable. This
is necessary if the channel is already
used by another application (e.g. WLAN).
If collision with other WLAN systems are
mentioned a distance of three channels
is recommended. (In case of doubt
please check before mounting.)
• Priority If the door does not unlock after pressing
the E Key* pad several times, it is neces-
sary to increase the priority of this door.
Otherwise it is possible to decrease the
priority of other doors in the near
distance.
• Restructure The internal data structure will be new
congured. It is recommended to use
this function if severel users are deleted.
By using the software* this function is
useless.
• Install keyboard After changing input or output unit both
units will be adjusted.
Menu Administrator Here you will nd all menus which are operatable with administrator rights only.
These are the following:
* Function only with Burg-Wächter product TSE E Key
Description of functions available via display
First openingPress key “On/Enter”, put in your opening
code works setting, open.You can change the administrator and the
user codes in the menu “code changed”
Below the menu structure with all input
possibilities is shown. Please nd the
instructions for programming the lock on
the display.
8/17/2019 Manual Chapa Electronica
4/9
15 16
en
■ Display
■ Input Administrator/ User
E = Enter
Further functions are available with the
software TSE Home and TSE Professionalwith USB wireless.
*Function only with Burg-Wächter product TSE E Key
Programming and operation diagramm
Menu Administrator
E
Menu Language/
Sprache
Choice
E
Menu Code changed
Administrator
User 001
User 299
Previous Code
New Code
Repeat entry
Code changecompleted
E
E
E
E
E
E
Menu Info
Burg Wächter TSE 3004 Vx.x
SN xxxxxxxx
E
E
MenuKey sync.
Key in pro.
mode Cont. withENTER
No E Key
available
Data are
stored
E
E
E
No E Keyavailable
E Key in Prog.
mode cont. withENTER
Admin. Setup
User Create
Store with
ON Key
Create
Code + E Key
Admin Code
E
Create E KeyCreate Code
Admin Code Admin Code
User xxxE Key store with
ENTER
User xxx
Code entry
User xxx
Code entry
Data are stored
Store with
ON Key
E Key store with
ENTER
E Key in Prog.
mode cont.
with ENTERE Keyalready
exist
Notpossible
Data arestored!
No E Keyavailable
E Keyalready
exist
Notpossible
Data arestored!
E
E
E
E E
E
E
E
E
E
E
E
E
Admin. Setup
Time entry
Admin. Code
Hour
Minute
Data arestored!
E
E
E
E
Admin. Setup
Date entry
Day
Month
Year
Data arestored!
E
E
E
Admin. Code
E
E
Admin. Setup
RFID channel
connection
channel 1
channel 12
Data are stored!
E
Admin Code
E
E
Admin. Setup
Priority
Priority
T □□□
T□□□□□□□
Data are stored!
Admin. Code
E
E
E
Admin. Setup
Restructure
Restructure inprogress!
Admin. Code
E
E
Admin. Setup
Install keyboard
Data are stored!
Admin. Code
E
E
Admin. Setup
Delete
Admin. Code
Data record isdeleted!
Data deleted
User 001
User 299
E
Delete
User
Delete
E Key
E
E
E
User 001
User 299
Admin. Code
Admin. Setup
E Key assign
User xxx
E Key store withENTER
E Key in Prog.
mode cont. withENTER
No E Key
available
E Keyalready
exist
Not
possibleData arestored!
E
E
E
E
E
Not possible
E E
8/17/2019 Manual Chapa Electronica
5/9
8/17/2019 Manual Chapa Electronica
6/9
· Batteriewechsel innen
· Changing of battery inside
· Changement des piles côté intérieur
· Batterij vervanging binnen
nl
en
fr
de
nl
en
fr
de
· Funktion Notschloss
· Function of the emengency lock
· Fonction de la serrure de secours
· Functie noodslot
50
8/17/2019 Manual Chapa Electronica
7/9
· Batteriewechsel außen· Changing of battery outside· Changement des piles côté
extérieur · Batterij vervanging buiten
1 2 3
2x 1,5V AA
1
2
1 2
12
2x 1,5V AA
de
fr
en
nl
3
· Beim Erscheinen der Batteriewechselaufforderung im Display der Tastatur
jeweils zwei Batterien innen und außen tauschen.
· If low battery consumption appears in the display you have to change batteriesinside and outside.
· Lorsque apparaît l’indicateur de piles faible dans la display du clavier, il est
impératif de changer les piles situées dans le clavier et celles près du cylindre.
· Bij het verschijnen van de lage batterijspanning indicator op het display, moeten
zowel de batterijen binnen als buiten vervangen worden.
· Batteriewechsel innen· Changing of battery inside
· Changement des piles côtéintérieur
· Batterij vervanging binnen
(LR6)
(LR6)
51
8/17/2019 Manual Chapa Electronica
8/9
Bild 3: Zum Schließen des Notschlosses muss der Drehknaufzwei Umdrehungen in beide Richtungen gedreht werden.
1
21
2
12
3
90°
nl
en
fr
de
90°
3
· Notschloss schließen· Locking of the
emergency lock
· Fermer la serrure de
secours
· Noodslot sluiten
Image 3: Pour fermer la serrure de secours, le bouton intérieur etextérieur doivent être tourné 2x à gauche et 2x à droite.
Afbeelding 3: Om het noodslot te sluiten moet de draaiknopbinnen en buiten zowel twee maal links als twee maal rechts
gedraaid worden.
Fig. 3: To lock the emergency lock the knob has to be turned twotimes in both directions.
· Funktion Notschloss
· Function of the emengency lock· Fonction de la serrure de secours
· Functie noodslot
· Notschloss öffnen· Opening the
emergency lock
· Ouvrir la serrure de
secours
· Noodslot openen
· Tür öffnen· Opening the door
· Ouvrir la porte
· Deur openen
52
8/17/2019 Manual Chapa Electronica
9/9
BURG-WÄCHTER KG Altenhofer Weg 15D - 58300 Wetter Germany
Druck-/ Satzfehler, Irrtum und Änderungen vorbehalten.
Typographical errors, omissions and changes reserved.Sous réserve de fautes d‘impression et de composition,d‘erreurs est de modications.
TSE 3004 Bedienungsanleitung