138
1 CARMANSCAN VG User Manual

Manual Carman Scan Vg

Embed Size (px)

Citation preview

Page 1: Manual Carman Scan Vg

1

CARMANSCAN VG

User Manual

Page 2: Manual Carman Scan Vg

2

CARMANSCAN VG Manual

CONTENT

CARMANSCAN VG INTRODUCTION

SAFETY

I. Mainframe Parts and Functions

1. Front ………………………………….…………………………… 10

2. Right Side ………………………………………………………… 12

3. Left Side …………………………..……………………………….13

4. Top ………………………………………………………………….14

5. Back………………………………………………………………….15

II. Status Display LED

1. Descriptions ........................................................................16

III. Pointing Device

1. About a Touch Panel...........................................................17

2. How to Use a Touch Panel..................................................18

IV. Battery

1. Battery Charging…. ……………………………………………..20

2. Battery Usage……………………………………………………..21

3. Checking Remaining Battery Power ……………………….21

Page 3: Manual Carman Scan Vg

3

CARMANSCAN VG Manual

CONTENT

4. Cautions in Handling …………………………………………22

V. External Display Device

1. Connection………………………………………………………...23

2. How to Connect ..………………………………………………...23

VI. Power Supply..………………………………………………….24

VII. Component List and Spec.

1. Components

1) Basic Items.…………………………………………………….25

2) Asia Kit..………………………………………………………..26

3) Europe/ USA Kit ……………………………………………...27

2. Option Items.………………………………………………………28

3. System Specifications

1) Hardware Spec. ……………………………………………..28

2) Protocol Spec…..………………………………………………29

3) Scope & Meter Spec..………………………………………..29

VIII. Pictures of Components

1. Basic Items...………………………………………………………30

Page 4: Manual Carman Scan Vg

4

CARMANSCAN VG Manual

CONTENT

2. Asian Kit …………………………………………………………...32

3. Europe Kit (Germany)………………………………………….. 34

4. Europe Kit (France)………………………………………………35

5. USA

Kit…...……………………………………………………………….35

IX. Main Menu

1. Screen Layout and Description……………………………….36

X. Vehicle Diagnosis Program

1. Connection to Vehicle & Selection of Diagnosis Program…….……38

2. Diagnosis Program..……………………………………………..45

XI. Maintenance Information

1. Main Menu…………………………………………………………61

2. Help per Part.…….……………………………………………….62

3. Help per Trouble Type...………………………………………..66

4. Vehicle Wiring Diagrams………………………………………..69

XII. Saved Data

1. Main Menu………………………………………………………….70

Page 5: Manual Carman Scan Vg

5

CARMANSCAN VG Manual

CONTENT

2. Saved Data in Fault Diagnosis Function …………………….71

3. Oscilloscope Saved Data….…………………………………….72

4. Screen Capture Data……………………………………………..73

XIII. Internet

1. Internet Connection……………………………………………..75

2. Internet Screen...………………………………………………...77

XIV. Oscilloscope

1. Connecting to a Vehicle…………………………………………78

2. Main Menu……………………….………………………………...80

3. Auto Measurement.…………….………………………………..81

4. Manual Measurement…….….……………………………….....82

5. Secondary Ignition waveform measuring method…………98

6. Ignition Waveform Measurement.…..………………………105

7. Comparison of Normal Waveform & Misfire Waveform……..111

8. Measurement of Waveform per Trouble Type ………….116

XV. Meter & Simulator

1. Main Menu………………………………………………………..117

Page 6: Manual Carman Scan Vg

6

CARMANSCAN VG Manual

CONTENT

XVI. Utility Box

1. Main Menu..........................................................................119

2. Calculator …………………………..……………………………121

3. Touch Screen Calibration ………….…………………………122

4. File Explorer …………………………………………………….123

XVII. Program Download

1. Main Menu……………………………………………………….124

2. Delete……………………………………………………………..125

3. Download……………………………….………………………..127

4. Hard Disk Information …………….…………………………..130

5. Internal Information ………………….………………………..130

6. Select File List ……………………….………………………..131

XVIII. Configuration Setting

1. Main Menu…………………………………………………………..132

XIX. CARMANSCAN VG PRINT SETUP…………………..136

Page 7: Manual Carman Scan Vg

7

CARMANSCAN VG Manual

Overview of CARMAN SCAN VG

The increased vehicle emissions resulting from the drastic increase in the number

of vehicles has now reached levels that threaten life on the earth.

Accordingly, the vehicle-related laws and regulations of the advanced countries

aim not only to reduce the exhaust gas emissions and prevent the global warming

but also to abandon the development of gasoline engines and promote the

development of new technology (e.g. electric/hydrogen cars). For this purpose

various laws and regulations (e.g. OBD2/EOBD4) have been established or

strengthened to encourage automakers to invest in high-cost and long-term

development.

Due to the widening gap between advanced car maintenance technology and the

skills of maintenance staff, the distribution level of maintenance technology is

absolutely low, increasing the time it takes for maintenance staff to identify the

cause of failures and troubleshoot vehicle problems. i.e., from the perspective of

economics and technology, maintenance staff are facing new challenges in

acquiring and utilizing the wide range of equipment required to measure and

analyze the various parts and systems.

This CARMAN SCAN VG includes the necessary measuring functions and serves

as a guideline for car maintenance to help staff understand the ever-changing

technologies in a short period of time. It also has a recording function allowing

recording of abnormal signals, which can then be replayed for analysis.

CARMAN SCAN VG is a complete integrated vehicle information measuring system

which delivers the car maintenance information of domestic vehicles in real time,

and which has the intelligent self-diagnosis and recording function, satisfying the

requirements of the information age.

To utilize the various measurement and diagnostic functions of CARMAN SCAN VG

and enhance the efficiency of maintenance work to the maximum extent, it is

essential to read this user manual carefully.

Page 8: Manual Carman Scan Vg

8

CARMANSCAN VG Manual

Overview of CARMAN SCAN VG

The core of this equipment is the software implemented by programs. Therefore,

the descriptions contained herein may differ from the latest version of such

programs in the future. With this in mind always refer to the latest version of user

manual available.

Nextech Co., Ltd.

Page 9: Manual Carman Scan Vg

9

CARMANSCAN VG Manual

Cautions in Use

Safety Instruction

Cautions in Use

The CARMAN SCAN VG described in this manual was manufactured for those who have the

basic knowledge required for its use.

Users should follow the safety instructions described in this manual for safe and efficient

use of the product.

The cautions in use are as follows:

Do not drop the product.

Never use the product without the rubber boot in place.

Do not put the product on a distributor or high-tension cables. Even

though CARMAN SCAN VG is manufactured to internally prevent the

interference from the electromagnetic waves, the strong interference

by excessive electromagnetic waves may damage the product.

The strong surge or electric shock applied to the power cable may

damage the power supply unit of the product. So, do not use the

product while the power supply is unstable.

The voltage rating of the AC/DC adaptor is 12V DC.

Be sure to use an AC/DC adaptor with the rated voltage.

The allowed power input to the oscilloscope is 0 - 500V DC.

Do not apply the out-of-range voltage to the input port of an

oscilloscope.

Page 10: Manual Carman Scan Vg

10

CARMANSCAN VG Manual

I. Mainframe Parts and Functions

1. Front

Fig. 1-1: Front view of Product

1. Status display LED

☞ Displays the status of the product.

2. Direction Key

☞ When selecting menu items, use these keys to move up, down, left and

right. (The functions of the keys on the right hand side can be changed with

those of the direction keys on the left hand side (10) via menus.)

3. ENTER/ESC

☞ With these keys, you can start, cancel, quit, or move one-step backward of

a program.

Page 11: Manual Carman Scan Vg

11

CARMANSCAN VG Manual

I. Mainframe Parts and Functions

4. HELP

☞ Pressing the HELP button for any function, displays the relevant description

is in detail.

5 / 7. SPEAKER

☞ Outputs the sound from the product.

Note! )

When you play sound with the built-in speaker, it may produce a splitting

sound if you raise the volume.

6. Special Function Keys (F1 ~ F6)

☞ Used to run application programs or special functions.

8. Power Button

☞ Used to turn the power of the mainframe on and off.

TIP)

If you press this button for 3 or more seconds while the power is on, power

is turned off.

9. O / X

☞ Provides a YES or NO function when removing trouble codes or starting

an actuator.

10. Direction Keys

☞ Provides Pg UP /Pg Down / HOME / END function.

(You can change the functions of these keys with those of the direction keys

on the right hand side (2) via menus).

11. LCD

☞ Displays the screen of the product.

CARMANSCAN VG includes a touch panel on the top of the LCD.

Page 12: Manual Carman Scan Vg

12

CARMANSCAN VG Manual

I. Mainframe’s Parts and Functions

2. Right Side of Mainframe

Fig. I-2 Right Side of Product

1. Headphone Port

☞ Headphone connecting port.

(Supports a mini plug with a diameter 3.5mm.)

This port may not support some shapes, so check it before purchasing one.

Page 13: Manual Carman Scan Vg

13

CARMANSCAN VG Manual

I. Mainframe’s Parts and Functions

3. Left Side of Mainframe

Fig. I-3 Left Side of Mainframe

1. External Display Device Connector (VGA)

☞ Used for connection to external display devices such as CRT monitor, etc.

2. Keyboard Connector

☞ Used for connection to a keyboard.

3. LAN Connector

☞ Used for connection to LAN cable.

Page 14: Manual Carman Scan Vg

14

CARMANSCAN VG Manual

I. Mainframe’s Parts and Functions

4. Top of Mainframe

Fig. I-4 Top of Mainframe 1. Power Connector ☞ A connector for connection to AC adaptor or vehicle battery.

2. RS 232 Connector

☞ A connector for connection to RS 232 cable.

3. DLC Communication Cable Connector

☞ A connector for connection to the DLC comm. cable for vehicle diagnosis.

4 / 5. USB Port

☞ Connector for connection to peripherals such as a printer or mouse which

supports USB connection.

CARMANSCAN VG’s USB connector supports both USB 2.0 and 1.1.

Note! )

When using the USB device not connected to external power source, the

maximum power consumption per port is 500mA.

For the details, see the manual of a USB device.

When connecting 2 or more PC cards or USB devices at the same time, use AC

adaptor. Using a battery will weaken the power of the battery.

6. Scope Cable Ports

☞ Ports used to connect cables for oscilloscope or multimeter functions.

Page 15: Manual Carman Scan Vg

15

CARMANSCAN VG Manual

I. Mainframe Parts and Functions

5. Back of Mainframe

Fig. I-5 Back of Mainframe

1. Pen for Touch Panel

☞ A pen for touch panel is placed here.

Be sure to put it back here after using it to prevent loss.

2. Support

☞ The support makes it easy to put the product on a working table for

convenient use.

3. Built-in Battery Pack

☞ A built-in battery pack is included.

4. Vent Hole

☞ Discharges the heat generated inside of the product.

If you turn on the power, the internal cooling fan rotates to discharge the heat.

Page 16: Manual Carman Scan Vg

16

CARMANSCAN VG Manual

II. Status Display LED

Fig. II-1 LED Window

1. Descriptions

1. POWER Lamp

☞ Will be lit when the power from AC adaptor is used.

2. BATTERY Lamp

☞ Will be lit when the power from the built-in battery is used.

3. LAN Lamp

☞ Will be lit when the product is connected to another computer or Internet via

a LAN able.

4. HDD (Hard disk) Lamp

☞ Will be lit when the built-in hard disk is used.

TIP)

Do not press the power button while HDD lamp is lit, as it may damage the hard

disk.

5. DLC Lamp

☞ Will be lit when the product is communicating with a vehicle via DLC cable.

6. TRIGGER

☞ Will be lit when a scope function is used or a trigger-specified wave-form is

displayed.

Page 17: Manual Carman Scan Vg

17

CARMANSCAN VG Manual

III. Pointing Device

1. About the Touch Panel

A touch panel is a convenient pointing device on a screen, in which you can

manipulate a mouse pointer directly.

You can operate the electro-magnetic induction touch panel attached to the LCD of

the CARMANSCAN VG by using the pen attached. Since you can manipulate it on

the screen directly, faster operation is possible.

POINT)

▶ If the pressing force of the pen tip is not sufficient, the unit may not recognize

the manipulation. So, use the pen applying appropriate and sufficient force.

▶ Manipulate the touch panel only with the attached pen.

▶ Do not touch the panel with a sharp object, as it may damage the touch panel or

LCD.

Page 18: Manual Carman Scan Vg

18

CARMANSCAN VG Manual

III. Pointing Device

1. How to Use a Touch Panel

● Tap

Press the screen once with a pen.

This is the same as a single left button click of a mouse.

● Double Tap

Press the screen twice consecutively and swiftly.

This is the same as double-clicking a mouse.

Page 19: Manual Carman Scan Vg

19

CARMANSCAN VG Manual

III. Pointing Device

● Drag

Move the pen keeping it in contact with the screen.

● Point

Press the screen with a pen tip and stay for 1-2 seconds.

This is the same as the right button clicking of a mouse.

Page 20: Manual Carman Scan Vg

20

CARMANSCAN VG Manual

IV. Battery

1. Charging the Battery

1) Connect AC adaptor.

- Charging is started, and if the unit is switched on, the battery icon’s scale

on the main screen and the remaining power (%) are displayed. (It is not

necessary to switch the CARMANSCAN VG on for charging).

2) Check the charged amount below the battery icon on the screen.

3) Disconnect the AC adaptor.

POINT)

▶ The battery charging time of CARMANSCAN VG is about 8 hours,

however, it will vary depending on the usage situation.

▶ For the newly purchased battery or a battery which has not been

charged for 1 or more months, charge it fully first before use.

▶ If the surrounding temperature is too low or high, the battery charging

capacity is decreased.

▶ If you charge a battery immediately after using it, the battery may not be

charged due to the activation of the battery protection function resulting

from high battery temperature. In this case, wait for a while until the battery

temperature is lowered.

Page 21: Manual Carman Scan Vg

21

CARMANSCAN VG Manual

IV. Battery

2. Use of Battery

This section describes how to use the battery of the CARMANSCAN VG.

1) Disconnect AC adaptor and press the power button.

POINT)

▶ If the surrounding temperature is low, the battery operation time is

shortened.

▶ The operation time of a fully charged new CARMANSCAN VG battery is

about 1 – 2 hours, however, it varies depending on the usage situation.

▶ If the battery temperature increases, the operation of the product may

become slow. In this case, connect AC adaptor.

2. Check of Remaining Battery Power

If the product is powered on, you can check the remaining battery power

level displayed in percentage (%) under the battery icon on the right top of

a screen.

POINT)

▶ Due to the characteristics of a lithium ion battery, the actual remaining

battery level may differ from what is displayed on the screen due to the

usage environment (e.g., the number of charges and discharges).

Page 22: Manual Carman Scan Vg

22

CARMANSCAN VG Manual

IV. Battery

3. Cautions in Handling

● The Battery is a very sensitive product. Do not give strong impact to it when

installing or removing it. For safety reasons, do not use a battery pack, which has

been severely shocked.

- A severely shocked battery may cause an electric shock or a rupture.

● Do not disassemble it.

- If you touch the inside of a battery after breaking it down, it may cause an

electric shock or a fire.

● Discharging

- A charged battery discharges power little by little even if you do not use it.

So, it is recommended to charge it right before using it.

- If you do not use a battery for a long time (e.g., I or months), remove and

store it in a cool place.

● About the lifetime

- If you do not use the mainframe for a long time, this may consume the

battery and weaken its power.

- Use the mainframe at least once a month and check the battery status.

- Leaving a battery in a high-temperature place may consume the battery and

weaken its power.

- Since a battery is a consumable product, using it for a long time may

decrease its charging capacity. In this case, replace it with a new one.

- If the battery operation time is excessively short, it means that the battery

lifetime has come to an end.

- Remove the used-up battery from the mainframe. Otherwise, it may cause

an electric shock or a fire.

● Disposition

- When disposing a battery, put an insulation tape over the battery connector

and take other necessary actions to prevent disconnection.

● Battery operation time

- The surrounding temperature affects the operation time of a battery. If the

temperature is low, the operation time may be shortened.

Page 23: Manual Carman Scan Vg

23

CARMANSCAN VG Manual

V. External Display Device

1. Connection

You can connect external display devices such as a projector, CRT or LCD display

to CARMAN SCAN VG.

When connecting or disconnecting an external display device, first

turn off the mainframe power and disconnect the AC adaptor.

Otherwise, it may cause an electric shock.

2. How to Connect

1. Turn off the power of the mainframe, and disconnect AC adaptor.

2. Connect the cable of the display device to the external display device

connector on the left side of the mainframe. See [Fig. I-3: Left Side of Mainframe].

3. Connect the power cable of CRT/LCD display, and turn on the power.

4. Connect AC adaptor to the mainframe, and turn the power on.

Page 24: Manual Carman Scan Vg

24

CARMANSCAN VG Manual

VI. Power Supply

CARMANSCAN VG can receive power in 5 ways as follows:

1. Cigar Lighter Cable

The cigar lighter cable can supply power to the product.

However, when the vehicle ignition switch is off or upon starting a vehicle,

power is not supplied to the cigar lighter socket.

2. Vehicle Battery

Connect the red clip of the battery connection cable to the (+) battery

terminal, and black clip to the (-) terminal. Connect the cigar lighter cable

between the battery connection cable and the product.

In this case, power is supplied anytime regardless of the ignition switch

status or vehicle starting.

Be careful when connecting the cable, as incorrect polarity may

damage the mainframe.

3. DLC Main Cable

Where the vehicle satisfies the OBD-II communication convention and uses a

16-pin diagnostic connector, the DLC main cable can supply power to the

product directly without a separate power supply.

4. Battery

The built-in battery can run the product for 1-2 hours without separate

power supply.

TIP)

The battery operation duration may vary depending on the usage and

environment.

4. AC/DC Adapter If AC/DC adapter is used as a power supply, the battery may be charged

automatically, and it may be used as the power source of the mainframe.

Page 25: Manual Carman Scan Vg

25

CARMANSCAN VG Manual

VII. Component List and Spec.

1. Components

1) Basic Items

NO. PART NUMBER ITEMS

1 11000-11000 MAINBODY

2 11000-11100 RUBBER SHROUD

3 11000-11110 CARRYING CASE

4 11000-11111 QUICK OPERATING MANUAL

5 11000-11210 DLC MAIN CABLE

6 11000-11220 CIGAR CABLE

7 11000-11230 POWER EXTENTION CABLE

8 11000-11240 SCOPE CABLE (4CHANNEL)

9 11000-11250 RS-232C CABLE

10 11000-11260 SECONDARY IGNITION PICK UP

11 11000-11270 USB CABLE

12 11000-11280 TIRIGGER PICK UP

13 11000-11290 AC/DC ADAPTER

14 11000-11300 RECHAGEABLE BATTERY SET

Page 26: Manual Carman Scan Vg

26

CARMANSCAN VG Manual

VII. Component List and Spec.

2) Asian Kit

NO. PART NUMBER ITEMS

1 11000-21100 HYUNDAI CABLE (12P) **

2 11000-21210 KIA ADAPTER (6+1PIN)

3 11000-21220 KIA ADAPTER (20PIN)

4 11000-21300 DAEWOO ADAPTER (12P)

5 11000-21410 SSANGYONG ADAPTER (14P)

6 11000-21420 SSANGYONG ADPTER (20P)

7 11000-21510 TOYOTA ADAPTER (17R)

8 11000-21520 TOYOTA ADAPTER (17C)

9 11000-21600 NISSAN, INFINITY ADAPTER (14P)

10 11000-21100 MITSUBISHI CABLE (12P) **

11 11000-21700 HONDA, ACURA ADAPTER (3P)

12 11000-21800 HONDA ADAPTER (5P)

13 11000-21810 MAZDA ADAPTER (17P)

14 11000-21820 MAZDA ADAPTER (6+1P)

15 11000-21910 SUBARU CABLE (9P)

16 11000-21300 ISUZU ADAPTER (12P)

17 11000-21100 PROTON CABLE (12P) **

** Same cable

Page 27: Manual Carman Scan Vg

27

CARMANSCAN VG Manual

VII. Component List and Spec.

3) European Kit

NO. PART NUMBER ITEMS

1 11000-31000 AUDI / VW CABLE (2+2P)

2 11000-32000 BMW ADAPTER (20P)

3 11000-33100 BENZ PIN BOARD (38P)

4 11000-33200 BENZ CABLE (3 LINER)

5 11000-33300 OPEL ADAPTER (10PIN)

6 11000-34000 PSA CABLE (2PIN)

7 11000-34100 PSA CABLE (30PIN)

8 11000-34200 RANAULT CABLE (12PIN)

4) Australian Kit

NO. PART NUMBER ITEMS

1 11000-21810 HOLDEN CABLE (6PIN)

2 11000-21300 FORD CABLE (20PIN)

Page 28: Manual Carman Scan Vg

28

CARMANSCAN VG Manual

VII. Component List and Spec.

2. Optional Items

NO. PART NUMBER ITEMS

1 11000-51000 PRESSURE VACUUM PICK UP

2 11000-52000 HIGH CURRENT PICK UP (1A~600A)

3 11000-53000 LOW CURRENT PICK UP (500mA~100A)

4 11000-54000 TEMPERATURE PICK UP

5 11000-55000 DLI IGNITION PICK UP

3. System Specifications

1) Hardware spec.

- System: 128MB SD-RAM

- Storage medium: HDD 40GB

- Display: 7" Color LCD, Touch Screen, VGA Out

- Scope: 4-channel scope, multi-meter

Measurement of secondary ignition waveforms

- Comm. port: DLC Port, Host USB 1.1, USB 2.0, Client LAN, RS-232

- Multimedia: Speaker Out, Video Out

- Key pad: 4 Direction keys, 6 Function keys (Bottom)

- Battery: Smart Li-ion battery, operable for about 1 hour

Page 29: Manual Carman Scan Vg

29

CARMANSCAN VG Manual

VII. Component List and Spec.

2) PROTOCOL Spec.

• J1850 (VPW, PWM)

• KWP2000

• ISO 9141-2

• CAN, J1587

3) Scope & Meter Spec.

3)-1 Scope Spec.

• 4-channel digital scope

• Voltage measurement range: ±500V

• Trigger function (Mode/Source/Level/Delay)

• Ground level adjustment function

• Waveform storage function

• Zoom function

3)-2 Meter Spec.

4-channel multi-meter

Voltage measurement: ±500VDC

Frequency measurement: 0 ~200 KHz

Duty measurement: 0 ~ 100 %

Resistance measurement: 0 ~ 40 ㏁

Temperature measurement: -20 ~ 150℃

Pressure measurement: VACUUM – 100psi,

PRESSURE – 200 Kpa AUTO UNIT CONVERSION

Current measurement: HIGH CURRENT 600A

LOW CURRENT 100A AUTO UNIT CONVERSION

Page 30: Manual Carman Scan Vg

30

CARMANSCAN VG Manual

VIII. Pictures of Components

1. Basic Items

Mainframe Cigar Cable

Bag Battery cable

Main cable Scope cable (4 CH)

Page 31: Manual Carman Scan Vg

31

CARMANSCAN VG Manual

VIII. Pictures of Components

RS232C Cable Secondary ignition pickup

Trigger pickup AC/DC adaptor

Charging battery pack

Page 32: Manual Carman Scan Vg

32

CARMANSCAN VG Manual

VIII. Pictures of Components

2. ASIAN KIT

KIA/MAZDA adapter (6+1P) Ssangyong adapter (14P)

KIA / Ssangyong adapter (20P) TOYOTA adapter (17C)

Daewoo/ISUZU adapter (12P) Ssangyong /NISSAN adapter (14P)

HONDA adapter (5P) MAZDA adapter (17C)

Page 33: Manual Carman Scan Vg

33

CARMANSCAN VG Manual

VIII. Pictures of Components

HONDA/ACURA adapter (3P)) TOYOTA adapter (17R)

SUBARU cable (9P)

HYUNDAI/ MITSUBISHI cable (12P)

Page 34: Manual Carman Scan Vg

34

CARMANSCAN VG Manual

VIII. Pictures of Components

3. EUROPEAN KIT (GERMAN)

BMW adapter (20P) Opel adaptor (10P)

BENZ cable (3 LINER) Audi/Volkswagen cable (2+2P)

BENZ pin board (38P)

Page 35: Manual Carman Scan Vg

35

CARMANSCAN VG Manual

VIII. Pictures of Components

4. EUROPEAN KIT (FRANCE)

PSA cable(2PIN) PSA cable(30P)

RANAULT cable(12P)

5. USA KIT

GM adaptor (12P) Ford adaptor (17P)

Page 36: Manual Carman Scan Vg

36

CARMANSCAN VG Manual

IX. Main Menu

1. Screen Layout and Description

Fig. IV-1: Main Screen Layout

1. Vehicle Diagnosis

: Provides the function to diagnose the vehicle and display sensor outputs via communication with a vehicle.

2. Information for Repair

: Provides help for diagnosing the engine’s electronic control system. Includes wiring diagrams, and other technical information.

3. Saved Data

: Displays saved data from sensors, waveforms and captured images.

Page 37: Manual Carman Scan Vg

37

CARMANSCAN VG Manual

IX. Main Menu

4. Internet

: Provides an Internet search function while LAN cable is connected. 5. Oscilloscope

: Using 4 channels, it provides the function to measure the primary and secondary ignition waveforms and the waveforms from sensors, actuators etc. plus a meter & simulator functions.

6. Utilities

: Provides the functions of a calculator, touch screen calibration, and a file browser

7. Program Download

: Provides the function to download or upload the data on the hard disk or internal memory.

8. Configuration

: Provides the function to change or modify the basic settings of the Carman Scan VG.

9. Battery Icon

☞ Shows the remaining power or charged state of the internal battery.

10. Keyboard Icon

☞ Displays or hides the keyboard for text input on a screen.

11. Capture Icon

☞ Provides a screen capture function.

Page 38: Manual Carman Scan Vg

38

CARMANSCAN VG Manual

IX. Main Menu

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

1. Connection to Vehicle & Selection of Diagnosis Program

1) Connecting to Vehicle

1. Connect the main cable to the DLC connector on the top of the CARMANSCAN

VG mainframe.

- Push in the levers on the both sides of the connector until you hear a click

sound.

Fig. Connecting to X-1 DLC Connector

2. Make a connection after checking the diagnostic connector’s position and

specifications of the vehicle to be diagnosed.

- Abnormal connection may cause defective communication.

Fig. X-2 Connecting to Vehicle Side Connector

Page 39: Manual Carman Scan Vg

39

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

2) Selecting a Diagnosis Program

1. On the main menu, tap on the vehicle diagnosis program item.

Fig. X-3 Main Menu

2. Tap on the vehicle maker’s country, and maker item to diagnose.

- If you select the area icon on the left, the maker pane is activated.

Fig. X-4 Main Screen of Diagnosis Program

Page 40: Manual Carman Scan Vg

40

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

Fig. X-5 Diag Language

If the diagnostic program in VG flash memory contains more than one

language,VG allows you to choose other languages for diagnosis.

Page 41: Manual Carman Scan Vg

41

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

Tap on the vehicle system item (engine, auto transmission, ABS, Air-bag, etc.) to

be diagnosed.

Fig. X-6 Diagnosis Program 3. “Connecting to ECM…” is displayed, and then the communication becomes active.

Fig. X-7 Communication Screen

TIPS)

When the communication is successful, [X-11 Main Diagnosis Screen]

appears, but if it fails, a “Communication Error” message is displayed.

If an error message is displayed, check if the diagnostic cable was connected

properly, and if you selected the correct vehicle type, model year, and system

spec., and then try again.

Page 42: Manual Carman Scan Vg

42

CARMANSCAN VG Manual

X. 차량 진단 프로그램

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

: Tap on the desired item to search or analyze the saved

data.

- Select a file name on the left pane to activate the right pane, and check the

saved information (e.g., vehicle type, saved date, number of saved items).

Fig. X-8 Saved Data List Screen

: Tap on “GRAPH” to check the saved data.

☞ You can check the saved data with this function.

☞ See Fig. X-8 Graph Screen

: Tap on “DEL” to delete a file.

☞ You can delete the selected data.

: Tap on “RENAME” to change a file name.

: Tap on “EXIT” to exit this menu.

Page 43: Manual Carman Scan Vg

43

CARMANSCAN VG Manual

X. 차량 진단 프로그램

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

Fig. X-9 Graph Screen

: Tap on “LIST” to return to the saved data list menu.

☞ Then, Fig. X-7: Saved Data List Screen is displayed.

: Tap on “VIEW CH +” to increase the number of signals

displayed on a single screen.

☞ The default number is 4.

☞ The number can be increased up to 8.

: Tap on “VIEW CH -” to decrease the number of the signals

displayed on a single screen.

: Tap on “UP” to move up to the upper items to be displayed

on the screen.

: Tap on “DOWN” to move down to the lower items to be

displayed on the screen.

Page 44: Manual Carman Scan Vg

44

CARMANSCAN VG Manual

X. 차량 진단 프로그램

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

: Tap on “DLC LOCATION” to check the location of the

ECU connector on the vehicle side.

TIP) This icon is activated only when you select the production region and a

maker of the vehicle to diagnose. See Fig. X-5

- You can check the diagnostic connector’s location of a vehicle as follows.

Fig. X-10: Diagnosis Connector Location-1 Screen

Fig. X-11: Diagnosis Connector Location-2 Screen

Page 45: Manual Carman Scan Vg

45

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

2. Diagnosis Program

1) Main Screen

[

Fig. X-12: Diagnosis Main Screen

1. Procedure for selecting a diagnosis menu

- Shows the procedure for selecting a diagnosis menu.

Country -> Maker -> Vehicle Type -> System -> System Spec.

2. Icon for returning to a main screen

: Pressing this icon on any menu displays the main menu again.

Fig. X-3 Main Menu

3. Trouble Code (Press F1 button or tap “DTC” on the screen)

- You can display the trouble code of the system, and delete a trouble code.

4. Sensor (Press F2 button or tap “SENSOR” on the screen)

- You can search the current values of the sensors of the relevant system.

Page 46: Manual Carman Scan Vg

46

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

5. Actuator (Press F3 button or tap “ACTUATOR” on the screen)

- You can check if the system is normal by forcibly starting or stopping the

actuators of the relevant system.

6. Other (Press F4 button or tap “ OTHER” on the screen)

- You can check the system spec and use various supplementary functions.

The actual functions will depend on the vehicle selected

7. DIAG Menu (Press F5 button or tap “ DIAG MENU” on the screen)

- Pressing this menu displays the diagnosis main screen again on any screen.

Fig. X-12: Diagnosis Main Screen

8. Home (exit from diagnosis) (Press F6 button or tap “HOME” on the

screen)

- Pressing this menu displays the system selection screen again on any

screen. Fig. X-57: Diagnosis Program

-

9. You can also operate the function on any menu by tapping on the screen

directly.

Page 47: Manual Carman Scan Vg

47

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

2) Major Functions

1. Trouble Code

- If troubles are detected, the trouble code, number of trouble codes and

description are displayed. If there is no trouble, “NO TROUBLE CODE” is

displayed as show in the Fig. V-9.

Fig. X-13: Trouble Diagnosis Screen

: If there is a fault code, tap on “ERASE” to delete the code.

☞ Deletes the displayed trouble code.

Be sure to delete trouble codes only when the ignition key is on and

an engine is off.

A trouble code may not be erased, or abnormal problems may occur

if deleting codes with the engine running.

TIPS) A temporary trouble code may be erased without repairing. But if

the fault is still valid, the code is erased temporarily, and will then

be displayed again.

: Tap on “HELP” to display the help items.

☞ You can check the help, circuit diagram and normal waveform of each

sensor item.

Page 48: Manual Carman Scan Vg

48

[ Fig. X-14 : 서비스데이터 화면 (TEXT VIEW) ]

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

2. SENSOR

- You can analyze the changes in the sensor or actuator values.

- Min. and Max. values can be compared.

Fig. X-14: Service Data Screen (Text view)

: Tap on “+FILE” to select the record mode or open a file.

☞ Then and are activated.

Fig. X-15: Text View Storage Screen

: Tap on “RECORD” to start a recording. ☞ You can save the value changes of the (fixed) items you have selected for later

analysis. Recording will continue until “RECORD” is pressed again. : Tap on ”OPEN” to open a recorded event.

☞ You can move to a screen where you can select the saved data.

Page 49: Manual Carman Scan Vg

49

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

: Tap on “+SEL ITEM” to add a sensor item on a Text screen. ☞ When the sensor data list pane on the Screen is activated, you can select new

items or delete previously selected items.

Fig. X-16 Text View Sel Item Screen

: Select an item to add, and then tap on “ADD FIX”. ☞ A new item is fixed, and you can see the data changes on the graph.

: Select an item to unfix, and then tap on “UNFIX”. ☞ The selected item is released from fixing.

Page 50: Manual Carman Scan Vg

50

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

: Tap on “+SIMU-SCAN”.

☞ This is for the simulation of voltage, frequency and duty while checking

the changes of the sensor data value using scope terminal.

Fig. X-17 Text View SIMU SCAN Screen

: Tap on “VOLT”.

☞ When the VOLT simulation pane on the right side is activated, you can do

the simulation using voltage.

: Tap on “FREQUENCY”.

☞ When the DUTY/FREQUENCT simulation pane on the right side is

activated, you can do the simulation using duty and frequency.

: Tap on “INIT MIN/MAX” to re-initiate Min/Max values.

☞ This initializes the MIN/MAX value of the sensors.

Page 51: Manual Carman Scan Vg

51

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

Fig. X-18 Service Data Screen (Graph view)

: Tap on “TEXT VIEW” to return to the text screen.

☞ You can move to the text view screen in Fig. X-14. : Tap on “+FILE” to select the record mode or open a file.

☞ Then and are activated.

: Tap on “RECORD” to start a recording. ☞ You can save the value changes of the (fixed) items you have selected for later

analysis. Recording will continue until “RECORD” is pressed again.

: Tap on ”OPEN” to open a recorded event. ☞ You can move to a screen where you can select the saved data.

Page 52: Manual Carman Scan Vg

52

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

: Tap on “+SEL ITEM” to add a sensor item on a graph screen. ☞ When the sensor data list pane on the right side is activated, you can select

new items or delete previously selected items.

Fig. X-19 Item Selection Screen

: Select an item to add, and then tap on “ADD FIX”. ☞ A new item is fixed, and you can see the data changes on the graph.

: Select an item to unfix, and then tap on “UNFIX”. ☞ The selected item is released from fixing.

Page 53: Manual Carman Scan Vg

53

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

/ : Tap on “CONFIG” to change the screen settings. ☞ Icons necessary for screen settings are displayed on the right hand side.

Fig. X-20 Settings Screen 1

: Tap on “VIEW CH +” to increase the number of sensor items

to be displayed on the screen.

☞ 4 items are displayed by default.

☞ But, the number can be increased up to 8.

: Tap on “VIEW CH -” to decrease the number of sensor items

to be displayed on the screen.

☞ The number can be decreased down to 1.

: Tap on “VIEW DATA” to remove or replace the numeric data

display on the graph.

☞ Data is displayed on the graph on the center of a screen.

: Tap on “VIEW RANGE” to remove or replace the MIN/MAX

values on the graph.

☞ Min/Max data is displayed on the right hand side of a graph.

Page 54: Manual Carman Scan Vg

54

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

: Tap on “VIEW NAME” to remove or replace the data item

names on the graph.

☞ The name is displayed on the left hand side of a graph.

TIP)

/ /

Data is displayed on the graph by default. To remove the display data on the

screen, tap on a relevant icon once. The icon then turns to a red color, and

the data will not displayed on the screen.

: To zoom the graph displayed on the screen, in or out,

tap on the “CH” icon until the desired sensor’s channel is

displayed and then tap the “MAX+” or “MAX-“ icon.

☞ To observe the graphical wave of a test item in more detail , you can tap on ‘+’ or ‘-‘ icon to zoom in or out the graph.

Page 55: Manual Carman Scan Vg

55

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

/ : Tap on “CONFIG / HOLD/RUN”.

☞ You can check the changes of the date through holding or running the screen..

Fig. X-21 Settings Screen 2

: Tap on “HOLD/RUN”.

☞ When you tap on "HOLD", the screen will be frozen and by tapping on "RUN" the screen will proceed again.

: Tap on “PAGE” to move the screen to backward or forward.

☞ You can check the saved screen by pages.

: Tap on "ZOOM" to zoom in or out the screen of the data

value.

☞ Default value is set up at 60 and you can zoom in and out by 10units.

Page 56: Manual Carman Scan Vg

56

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

3. HELP - Displays the help information of individual items of data.

Fig. X-19 Help Items

: Tap on “TIPS” to view the information. ☞ You can view the standard values and repair information of the selected item.

Fig. X-20 TIPS

Page 57: Manual Carman Scan Vg

57

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

: Tap on “WAVE” to view a sample lab scope waveform. ☞ You can view the normal waveform of a selected item.

Fig. X-21 WAVE

: Tap on “CIRCUIT” to view the wiring diagram of a selected item.

☞ You can view the circuit diagram of a selected item.

[Fig. X-22 CIRCUIT]

/ : Tap on “UP” or “DOWN” to move a screen upwards or downwards.

Page 58: Manual Carman Scan Vg

58

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

4. ACTUATOR - You can check if an actuator is normal by forcibly starting and stopping it.

Fig. X-23 Actuator Screen

TIP) When you select a test item on the actuator list, the “START” and “STOP” icons on the left hand side are activated, and DURATION, test METHOD, and test CONDITION are displayed on the right hand side.

: Tap on “START” to start or stop an actuator forcibly. ☞ Pressing this icon starts the actuation.

: Tap on “STOP” to stop an actuator being tested. ☞ Pressing this icon stops the actuation.

Page 59: Manual Carman Scan Vg

59

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

5. Other - You can check various adaptive values, system reset, and system specifications information.

Fig. X-24 OTHER Screen

Fig. X-25 Resetting Adaptive Values

: Tap on “Yes” to confirm you want to delete the adaptive values or execute the selected command.

☞ Confirms the deletion of adaptive values or execution of a command once more before performing it.

Page 60: Manual Carman Scan Vg

60

CARMANSCAN VG Manual

X. Vehicle Diagnosis Program

: Tap on “No” if you do not want to delete the adaptive values or execute the selected command.

☞ Confirms you do not want to carry out the deletion of adaptive values or execution of a command once more before performing it.

: Tap on “ENTER” if you want to execute the command. ☞ Executes a command.

: Tap on “ESC” to quit the function. ☞ Use this icon to cancel a command or quit a function.

: Tap on the desired numbers. ☞ Use this icon to enter numbers.

: Tap on “REST” to reset the adaptive values. ☞ Resets the adaptive values or system resetting items.

Page 61: Manual Carman Scan Vg

61

CARMANSCAN VG Manual

XI. Maintenance Information

1. Main Menu

Fig. XI-1: Maintenance Information Main Screen

: Tap on “Sorted by Parts”.

☞ You can view the help for the parts of 4 systems – Engine / Engine(LPG)

/ ABS / Suspension.

: Tap on “Sorted by Troubles”.

☞ You can view the help for common faults of 4 systems – Engine /

Engine(LPG) / Auto Transmission / Suspension.

: Tap on “Vehicle Diagram”.

☞ You can view the circuit diagrams of a vehicle per maker.

Page 62: Manual Carman Scan Vg

62

CARMANSCAN VG Manual

XI. Maintenance Information

2. Help per Part

- You can view the help for the parts of 4 systems – Engine / Engine (LPG) /

ABS / Suspension.

Fig. XI-2 Help per Part

: Tap on “Troubles”.

☞ You can view the faults and repair methods of a selected part.

Fig. XI-3 Trouble Descriptions

Page 63: Manual Carman Scan Vg

63

CARMANSCAN VG Manual

XI. Maintenance Information

: Tap on “Parts Photo”.

☞ You can view the picture of a selected part.

Fig. XI-4 Part Picture

: Tap on “EMS Configuration”.

☞ You can view a simple EMS diagram of a selected item.

Fig. XI-5 EMS Simple Diagram

Page 64: Manual Carman Scan Vg

64

CARMANSCAN VG Manual

XI. Maintenance Information

: Tap on “Part Explanation”.

☞ You can view the detailed description and functions of parts.

Fig. XI-6 Part Description

: Tap on “Part Characteristics”.

☞ You can view the help regarding characteristics of a selected part.

[Fig. XI-7 Part Characteristics]

Page 65: Manual Carman Scan Vg

65

CARMANSCAN VG Manual

XI. Maintenance Information

: Tap on “EMS Understanding”.

☞ You can view the help for the EMS algorithm.

Fig. XI-8 Understanding the Mechanism

: Tap on “Vehicle Diagram”.

☞ Displays a Vehicle Diagram menu.

: Tap on “Sorted by Troubles”.

☞ Displays the Help per Trouble menu.

: Tap on “Left Arrow”.

☞ Displays [Fig. XI-2] screen.

: Tap on “Right Arrow”.

☞ Displays the previous screen.

Page 66: Manual Carman Scan Vg

66

CARMANSCAN VG Manual

XI. Maintenance Information

3. Help per Trouble Type

- You can view the help for the common faults of 4 systems – Engine / Engine

(LPG) / Auto Transmission / Suspension.

Fig. XI-9 Help per Trouble Type

: Tap on “Cause of Trouble”.

☞ Displays the help for causes of a fault.

Fig. XI-10 Cause of Problem

Page 67: Manual Carman Scan Vg

67

CARMANSCAN VG Manual

XI. Maintenance Information

: Tap on “Related Part”.

☞ Displays the description of the parts related to the fault.

Fig. XI-11 Related Part

: Tap on “Analysis Method”.

☞ Displays the help for fault analysis methods.

Fig. XI-12 Analysis Method

Page 68: Manual Carman Scan Vg

68

CARMANSCAN VG Manual

XI. Maintenance Information

: Tap on “Vehicle Diagram”.

☞ Displays a circuit diagram.

: Tap on “Sorted by Parts”.

☞ Displays the Help per Part Type.

: Tap on “Left Arrow”.

☞ Displays Fig. XI-9 screen.

: Tap on “Right Arrow”.

☞ Displays the previous screen.

Page 69: Manual Carman Scan Vg

69

CARMANSCAN VG Manual

XI. Maintenance Information

4. Vehicle Wiring Diagram

- You can view the wiring diagrams of each system of a vehicle per maker.

Fig. XI-13 Vehicle Diagram Menu

- If you drag the screen, the position of the diagram will move accordingly.

Fig. XI-14 Vehicle Wiring Diagram

: Tap on “Left Arrow”.

☞ Displays Fig. XI-13 screen.

: Tap on “Right Arrow”.

☞ Displays the previous screen.

Page 70: Manual Carman Scan Vg

70

CARMANSCAN VG Manual

XII. Saved Data

5. Main Menu

- You can view the diagnosis data, oscilloscope data, screen capture files, etc

which have been saved in memory.

Fig. XII-1 Saved Data

: Tap on “SAVED DATA OF DIAGNOSIS” to search or analyze

the saved diagnosis data.

☞ Displays the files saved in the diagnosis program.

: Tap on “SAVED DATA OF OSCILLOSCOPE” to search or

analyze the saved oscilloscope waveforms.

☞ Displays the files saved in the oscilloscope function.

: Tap on “IMAGE VIEWER” to view the capture screens.

☞ Displays the capture files.

Page 71: Manual Carman Scan Vg

71

CARMANSCAN VG Manual

XII. Saved Data

2. Saved Data in Fault Diagnosis Function

- You can view the data saved in the fault diagnosis function.

Fig. XII-2 Saved Data in Fault Diagnosis Function

: Tap on “GRAPH” to check selected saved data file.

☞ Displays the saved data.

☞ See Fig. X-8 Graph Screen.

: Tap on “DEL” to delete selected saved data file.

☞ Deletes the selected data.

: Tap on “RENAME” to change a saved file name.

: Tap on “EXIT” to quit this menu.

Page 72: Manual Carman Scan Vg

72

CARMANSCAN VG Manual

XII. Saved Data

3. Oscilloscope Saved Data

- You can view the waveforms saved from the oscilloscope.

Fig. XII-3 Oscilloscope Saved Data

: Tap on “VIEW” to view the saved waveforms.

☞ Displays the saved waveforms.

: Tap on “RENAME” to change a saved file name. ☞ Changes a file name.

: Tap on “DELETE” after selecting a file name to delete. ☞ Deletes the selected data.

Page 73: Manual Carman Scan Vg

73

CARMANSCAN VG Manual

XII. Saved Data

4. Screen Capture Data

- You can view the captured screen data.

[Fig. XII-4 Screen Capture Data]

: Tap on “SLIDE SHOW”.

☞ You can see the saved screen by capture one after the other..

: Tap on “SLIDE CONFIG”.

☞ You can set-up the showing time and frequency. TIP)

☞ Up to 13 files can be displayed at a time on the image list pane.

☞ Use / icon to view other files than those displayed on

the screen

: Tap on “DELETE” after selecting a file to delete. ☞ Deletes the selected data.

: Tap on “REFRESH”. ☞ Refreshes the screen.

☞ Pressing this button when a new file is added or deleted will reflect

such change on a screen.

Page 74: Manual Carman Scan Vg

74

CARMANSCAN VG Manual

XII. Saved Data

Fig. XII-5 Full Screen

: Tap on “FULL SCREEN”. ☞ As shown in Fig. XII-5, the IMAGE LIST pane disappears, and a captured

screen is displayed on the entire window.

: Tap on “MENU”.

☞ Goes back to Fig. XII-4 screen.

Page 75: Manual Carman Scan Vg

75

CARMANSCAN VG Manual

XIII. Internet

1. Internet Connection

1. Connect a LAN cable to the LAN port on the left side of a mainframe.

Fig. XIII-1 LAN Cable Connecting Method

TIP) A separate LAN cable may be required depending on the Internet environment. You can connect a LAN cable for an external modem where ADSL is used.

TIP)

If you use a fixed IP, you have to enter IP address, subnet mask and gateway value

before using it.

If you use a dynamic ID like as in ADSL or VDSL, no additional setting is required.

Page 76: Manual Carman Scan Vg

76

CARMANSCAN VG Manual

XIII. Internet

2. CARMANSCAN VG performs a network setting. ☞ Setting is done in the following way.

Page 77: Manual Carman Scan Vg

77

CARMANSCAN VG Manual

XIII. Internet

2. Internet Screen - Through Internet, you can download a diagnostic program and maintenance

information, or surf the Internet.

[Fig. XIII-2 Internet]

Page 78: Manual Carman Scan Vg

78

CARMANSCAN VG Manual

XIV. Oscilloscope

1. Connecting to a Vehicle

1. Connect a scope cable to CARMANSCAN VG mainframe.

Fig. XIV-1 Scope Cable Connecting Method 1

▶ Align the up and down grooves of a scope cable with the protrusions of a scope port,

and then turn and fix it.

SCOPE CABLE TERMINAL MAIN-BODY SCOPE TERMINAL

Page 79: Manual Carman Scan Vg

79

CARMANSCAN VG Manual

XIV. Oscilloscope

2. Connect a probe to the signal line of a vehicle sensor, and connect the ground

clamps to a proper location.

Fig. XIV-2 Scope Cable Connecting Method 2

TIP)

In general, the wiring of a vehicle sensor consists of power cable, ground cable and

signaling cable.

A signaling cable sends or receives signals via connection to the ECU.

When testing using the oscilloscope, you can identify the waveform via this signaling

cable.

Page 80: Manual Carman Scan Vg

80

CARMANSCAN VG Manual

XIV. Oscilloscope

2. Main Menu

- Here, you can measure vehicle sensors, actuators and ignition waveforms, and use the automatic measurement function “per trouble type”.

Fig. XIV-3 Main Menu

: Tap on “Auto setup”.

☞ Displays the waveforms of sensors and actuators with the voltage and time values preset in the oscilloscope

: Tap on “Manual setup”.

☞ You can use the oscilloscope function via user manipulation.

: Tap on “Ignition waveform”.

☞ Allows the measurement of Secondary ignition waveforms via preset screens.

: Tap on “Analyze by trouble type”.

☞ Function to measure the related sensors or actuators for each trouble type.

: Tap on “Load Wave file”.

☞ Function to display the saved waveforms.

Page 81: Manual Carman Scan Vg

81

CARMANSCAN VG Manual

XIV. Oscilloscope

3. Automatic Measurement

- Displays the waveform automatically when a measurement target sensor or actuator is selected out of the 33 items.

Fig. XIV-4 Automatic Measurement 1. Sensor and Actuator items

A list of 33 items is displayed.

- You can select the item to test and its type.

2. Channel (4 channels are displayed).

- Select an item, and then select a channel to use.

3. Channel Item

- The items and channels, which were selected in the step 1 and 2, above are

displayed on the channel fields.

4. SAVE

- Pressing this icon saves the setting values and displays the scope waveform

measurement screen.

5. CANCEL

- Pressing this icon deletes all settings. You can then set the item and channel

again.

Page 82: Manual Carman Scan Vg

82

CARMANSCAN VG Manual

XIV. Oscilloscope

4. Manual Measurement

- You can set the voltage, time and trigger as you want.

Fig. XIV-5 Manual Measurement

: Tap on “VOLT/DIV.

☞ You can set the voltage axis.

: Tap on “TIME/DIV.

☞ You can set the time axis.

: Tap on “TRIGGER”.

☞ You can set the trigger.

: Tap on “STOP”.

☞ You can stop a screen, and save the measured waveform which has been automatically recorded prior to that point. If there has not been sufficient time to capture a full recording you will be prompted to wait while to rest of the recording is completed.

Page 83: Manual Carman Scan Vg

83

CARMANSCAN VG Manual

XIV. Oscilloscope

: Tap on “SCREEN”.

☞ You can change to the screen configuration mode.

: Tap on “CURSOR”.

☞ You can change to the cursor position mode.

TIP)

Basically, the menus of the Auto Setup are the same as those of the Manual

Setup measurement screen. The difference is – in the auto setup, a desirable

voltage/time setting is preset for each item being tested; while in the manual

setup, the user may set it as desired.

Page 84: Manual Carman Scan Vg

84

CARMANSCAN VG Manual

XIV. Oscilloscope

1. Voltage Setting

- The vertical line on the grid displayed on the screen is the voltage axis.

The user can adjust the size of one scale from a minimum 20mV to maximum 50V

per division.

Fig. XIV-6 Voltage Setting

: Tap on “CHANNEL”.

☞ Activates channels from CH1 to CH4 in sequence.

: Tap on “Up” or “Down” arrows.

☞ You can adjust the voltage of a selected channel.

: Tap on “Return” Arrow.

☞ The screen returns to Fig. XIV-5 Manual Measurement screen.

Page 85: Manual Carman Scan Vg

85

CARMANSCAN VG Manual

XIV. Oscilloscope

TIP)

☞ Channel and voltage setting

As shown in Fig. XIV-7 Channel Setting Box, you can also activate a relevant

channel by tapping on the box assigned to each channel, and set the voltage using

Up/Down button.

☞ AC/DC setting

By tapping the AC icon shown in the Fig. XIV-7 Channel Setting Box, you can

switch from DC to AC measurements.

AC measurement is available only in CH1.

Fig. XIV-7 Channel Setting Box.

Page 86: Manual Carman Scan Vg

86

CARMANSCAN VG Manual

XIV. Oscilloscope

2. Time Setting

- The horizontal line on the grid displayed on the screen is the time axis.

- A user can adjust the scale from a minimum 50㎲ to maximum 10s.

Fig. XIV-8 Time Setting

: Tap on “Left” or “Right” Arrow. ☞ You can change the time setting.

: Tap on “Return” Arrow. ☞ The screen returns to a Fig. XIV-5 Measurement Screen.

TIPS)

You can also change the time setting by manipulating the LEFT/RIGHT icon on the

right side.

Page 87: Manual Carman Scan Vg

87

CARMANSCAN VG Manual

XIV. Oscilloscope

3. Trigger

- You can change the trigger settings.

Fig. XIV-9 Trigger

: Tap on “CHANNEL”.

☞ The channel in the trigger box is changed.

☞ Each tapping on the icon changes the channel from CH1 to CH4 one by one.

: Tap on “TYPE”.

☞ Changes the type of trigger.

☞ Each tapping on the icon makes a change from Rising to Falling, or Falling to Rising.

: Tap on “MODE”.

☞ Changes the trigger mode.

☞ Each tapping on the icon changes the trigger mode between ▶AUTO ▶NORMAL

▶SINGLE in a regular order.

Page 88: Manual Carman Scan Vg

88

CARMANSCAN VG Manual

XIV. Oscilloscope

: Tap on “LEVEL”.

☞ By using the UP/DOWN direction key on the left side or by dragging the

left top of the screen, you can set the trigger level.

: Tap on “POS”.

☞ By using the LEFT/RIGHT direction key on the left side or dragging the

left top of a screen, you can set the trigger position.

: Tap on “Return” Arrow.

☞ The screen returns to Fig. XIV-5 Measurement Screen.

TIPS)

- Using the icon below, you can change the trigger settings.

: By tapping on the channel pane, you can change the channels.

: By tapping on the arrow shape, you can change the type.

: By tapping it, you can change the mode.

: Re-activates the screen stopped by trigger setting.

TIPS)

- What is a trigger? A trigger is a function to display the repeated or

intermittent signals in a good-to-view waveform on the screen according

to the channel, voltage level, screen, position settings, etc. When

triggered correctly the pattern should stay steady on the screen.

Page 89: Manual Carman Scan Vg

89

CARMANSCAN VG Manual

XIV. Oscilloscope

4. Stop

- This function stops a screen, and then allows replaying of the waveforms which

were recorded prior to pressing the stop function icon.

Fig. XIV-10 Stop

: Tap on “Left” Arrow.

☞ Navigates a saved file in a reverse direction.

: Tap on “Pause”.

☞ Pause (temporary stop) during file navigation.

: Tap on “Right” Arrow.

☞ Navigates a saved file in a forward direction.

: Tap on “CURSOR”.

☞ Measures the time and voltage value of a saved waveform.

Page 90: Manual Carman Scan Vg

90

D

CARMANSCAN VG Manual

XIV. Oscilloscope

: Tap on “Return” Arrow.

☞ Returns the screen to Fig. XIV-5 Measurement Screen.

: Tap on “FILE”. ☞ Pressing it activates an Open and Save icon, allowing you to save a stopped

waveform, or open another saved waveform.

: Tap on “OPEN”. ☞ Opens a saved file for analysis.

[ Fig. XIV-11 Open ]

: Tap on “VIEW”.

☞ Displays a waveform in a saved file.

: Tap on “DELETE”. ☞ Deletes a saved file.

: Tap on “RENAME”.

☞ Changes a name of a saved file.

Page 91: Manual Carman Scan Vg

91

CARMANSCAN VG Manual

XIV. Oscilloscope

: The user can navigate a waveform in a forward and reverse direction, and use the Pause and Zoom-in function.

[ Fig. XIV-12 View Waveform ]

: Tap on “FILE”.

☞ Returns to Fig. XIV-11 Open.

: Tap on “Left” Arrow.

☞ Navigates a saved file in a reverse direction.

: Tap on “Pause”.

☞ Pause (temporary stop) during file navigation.

: Tap on “Right” Arrow.

☞ Navigates a saved file in a forward direction.

: Tap on “CURSOR”.

☞ Measures the time and voltage value of a saved waveform.

Page 92: Manual Carman Scan Vg

92

CARMANSCAN VG Manual

XIV. Oscilloscope

: You can zoom in or out of a saved waveform for analysis.

[ Fig. XIV-13 Zoom In/Out ]

: Tap on “Left” or “Right” Arrow.

☞ Zooms in/out a time axis to analyze a waveform.

: Tap on “Up” or “Down” Arrow. ☞ Zooms in/out a voltage axis to analyze a waveform.

: Tap on “Return” Arrow. ☞ Returns to Fig. XIV-12 View Waveform.

Page 93: Manual Carman Scan Vg

93

CARMANSCAN VG Manual

XIV. Oscilloscope

: You can save the temporarily stored waveform on the hard disk.

Fig. XIV-14 Save

Page 94: Manual Carman Scan Vg

94

CARMANSCAN VG Manual

XIV. Oscilloscope

5. Screen

- You can change the screen configuration.

Fig. XIV-15 Screen Mode

: Tap on the “Default Measurement Icon”.

☞ Pressing this icon displays the default waveform measurement

screen mode as shown in the figure above.

: Tap on the “Waveform Only Icon”.

☞ Pressing this icon displays only waveforms on a screen as shown in

the figure below.

Fig. XIV-16 Screen Mode

Page 95: Manual Carman Scan Vg

95

CARMANSCAN VG Manual

XIV. Oscilloscope

: Tap on the “Digital Data Display Icon.

☞ Displays the measured data of each waveform in detail.

Fig. XIV-17 Screen Mode

: Tap on “GRID”.

☞ The mode is changed to allow changing of the screen settings.

Fig. XIV-18 Grid

Page 96: Manual Carman Scan Vg

96

CARMANSCAN VG Manual

XIV. Oscilloscope

: Tap on “PEAK MODE”.

☞ A mode where you can observe the peak point of a waveform in detail

: Tap on “Quarter Grid”.

☞ Changes a screen configuration as shown in the screen below.

Fig. XIV-19 Screen Configuration

: Tap on “Full Grid”.

☞ Default screen configuration. Fig. XIV-18 Grid

: Tap on “No Grid”.

☞ Dotted lines disappear on the screen, and only waveforms are

displayed.

Page 97: Manual Carman Scan Vg

97

CARMANSCAN VG Manual

XIV. Oscilloscope

6. Cursor

You can make a cross type cursor on a screen, and select a point on a

waveform to analyze data.

Fig. XIV-20 Cursor Procedure:

• Press the Cursor icon once and the first X/Y axis cursors will be

displayed and highlighted on the screen.

• Drag these Cursors to the first point of measurement required.

• Press the Cursor icon a second time to highlight the second set of X/Y

axis cursors.

• Drag these Cursors to the second point of measurement required.

• Pressing the Cursor icon a third time will remove all Cursors from the

screen.

• Whilst there are Cursors on the screen, voltage and time measurements

will be displayed at the bottom of the screen in relation to the position of

the Cursors.

Page 98: Manual Carman Scan Vg

98

CARMANSCAN VG Manual

XIV. Oscilloscope

5. Secondary Ignition waveform measuring method.

- VG scope terminal characteristics and basic points.

[ Fig. XIV-21 VG scope terminal characteristic ]

As shown on [ XIV-21 ], Oscilloscope terminal characteristic is classified with

CH1 – For the positive measurement, CH2 – For the negative measurement and CH3

– For the trigger pick up.

The role of trigger pick up is to distinguish waveform of cylinder by connecting to

No.1 cylinder. If the probe is not connected properly according to the characteristic

of the channel, normal waveform detection will not be possible.

Above characteristics only correspond to the ignition waveform measurement and

for the use of normal scope function you can use any channel from 1 to 4 to

measure the waveform.

Page 99: Manual Carman Scan Vg

99

CARMANSCAN VG Manual

XIV. Oscilloscope

1. DISTRIBUTOR type

1) Ignition pick up

- [ XIV-23 ] Connect Secondary Ignition Pick up (which is bitten to CH2 of VG

scope terminal) to the distributing wires (which is connected to the center

electrode of the power distributor (No.1) from the ignition coil).

* Since the ignition waveform of power distributor type comes out as a

negative, please connect ignition pick up to CH 2.

2) Trigger pick up

- [ XIV-23 ] This is for the cylinder distinction. Connect it to the high-tension

cable (No.2) of the No.1 cylinder.

- Check SPARK PLUG mark on the trigger pick up and connect it through

correct direction.

[ Fig. XIV-22 Trigger Pick UP ]

[ Fig. XIV -23 Power Distributor Type ]

Page 100: Manual Carman Scan Vg

100

CARMANSCAN VG Manual

XIV. Oscilloscope

2. DLI(DISTRIBUTORLESS IGNITION) Type

1) Ignition pick up

- Connect DLI pick up (which is connected to the CH1 VG scope terminal) to

the No.1 and No.2 cylinder high-tension cable of ignition coil.

[No.1 and 3 high-tension cable of Fig. XIV-24]

- Connect DLI pick up (which is connected to the CH2 VG scope terminal) to

the No.3 and No.4 cylinder high-tension cable of ignition coil.

[No.2 and 4 high-tension cable of Fig. XIV-24]

* However, if the ignition waveform cannot be measured after connecting the

probe as written above, please change the position of probe connected to the CH1

and probe connected to the CH2 for reexamination.

* DLI pick up is composed with two cables as one set and this is an optional item.

2) Trigger pick up

- For cylinder distinction, please connect trigger pick up to the No.1 high-

tension cable.

- If the No.1 cylinder of the vehicle you want to measure is positive, please

connect trigger pick up to the high-tension cable on opposite direction of

SPARK PLUG. [No.1 high-tension cable of Fig. XIV-24]

[ Fig. XIV-24 DLI Type ]

Page 101: Manual Carman Scan Vg

101

CARMANSCAN VG Manual

XIV. Oscilloscope

3. COIL ON PLUG Type

- This is the type that an ignition coil is located on a spark plug without a high-

tension cable. It has two types depends upon vehicle maker.

- An ignition coil and a spark plug separable type.

- An ignition coil and a spark plug inseparable type.

Coil on plug type cannot measure the ignition waveform by an ignition pickup. It

requires a special cable.

An ignition coil and a spark plug separable type connection method.

1) Detach tube. Fig. XIV-25

[ Fig. XIV-25 ]

2) Connect a high-tension cable where a tube is detached.

- Prepare high-tension cables as many as vehicle cylinders.

- Connect each high-tension cable with each cylinder. Fig. XIV-26

[ Fig.XIV-26 ]

Page 102: Manual Carman Scan Vg

102

CARMANSCAN VG Manual

XIV. Oscilloscope

3) Connect DLI Second Ignition Pickup with connected high-tension cable.

- When they are connected, be aware of negative and positive signs as same as DLI

type measurement. Fig. XIV-27

- Connect a Trigger Pickup with a high-tension cable that is connected No.1

cylinder for Cylinder distinction.

[ Fig. XIV-27 ]

Page 103: Manual Carman Scan Vg

103

CARMANSCAN VG Manual

XIV. Oscilloscope

An ignition coil and a spark plug inseparable type connection method

1) Prepare picture-like cable. Fig. XIV-28

- Connect a processed spark plug with a DLI high-tension cable.

- Prepare high-tension cables as many as vehicle cylinders.

[ Fig. XIV-28 ]

2) Connect a spark plug of prepared high-tension cable with a spark tube of

an ignition coil, which is detached from vehicle. Fig. XIV-29

- Connect it with each cylinder.

[ Fig. XIV-29 ]

Page 104: Manual Carman Scan Vg

104

CARMANSCAN VG Manual

XIV. Oscilloscope

3) Connect DLI Second Ignition Pickup with a high-tension cable.

- When they are connected, be aware of negative and positive signs as same

as DLI type measurement. Fig. XIV-30

- Connect a Trigger Pickup with a high-tension cable that is connected No.1

cylinder for Cylinder distinction.

[ Fig. XIV-30 ]

* Users should manufacture connection cables for measurement of COIN ON PLUG

type. Also, connection cable should be manufactured depends on measuring vehicle

types, because its length and thickness of a high-tension plug tube might be different

depends on vehicles.

* For measurement methods besides connection steps, refer to the DLI type.

* Users can use DLI high-tension cable that is alike a spark plug. Also, in some

cases, users can process spark plug like [Picture XIV-28] to use for ignition

waveform measurement.

Page 105: Manual Carman Scan Vg

105

CARMANSCAN VG Manual

XIV. Oscilloscope

6. Ignition Waveform Measurement

- This function is used to measure a Secondary Ignition Waveform.

[ Fig. XIV-31 Ignition Waveform Setting Window ]

1. Cylinder Select Window

- Select the number of cylinders to be measured.

2. Type Select Window

- Select the type of vehicle’s ignition system to measure (e.g. Distributor or DLI)

☞ If you select an item in the Cylinder Select window, then this window is activated.

3. Probe Type Select Window

- Select the probe type, e.g. “1.1” for conventional ignition using a main coil lead and

“1 to 3” or “1 to 4” when using the DLI Multi lead pickups.

4. OK

- Setting has been completed, and a measurement screen is displayed.

5. CANCEL

- Cancel the settings. You can then make the settings again.

Page 106: Manual Carman Scan Vg

106

CARMANSCAN VG Manual

XIV. Oscilloscope

Fig. XIV-32 Measurement of Ignition Waveform

: Tap on “SET VOLT”. ☞ You can set the voltage axis.

: Tap on “SET TIME”.

☞ You can set the time axis.

: Tap on “TRIGGER”.

☞ You can set a trigger level and trigger voltage value.

: Tap on “CYLINDER”.

☞ You can change the selected single cylinder shown at the bottom.

: Tap on ”SCREEN”.

☞ You can change the waveform display method on the screen. See Fig. XIV-33~37 Screen Settings.

Page 107: Manual Carman Scan Vg

107

CARMANSCAN VG Manual

XIV. Oscilloscope

: Tap on “INFOR.”.

☞ Pressing the Information icon, removes or replaces the digital information displayed on the screen.

: You can split a screen to display the waveforms of the

entire cylinders on the top, and a waveform of each

cylinder at the bottom.

Fig. XIV-33 Screen Settings – Split Mode

TIPS)

- The ignition waveform screen is set to a split mode by default.

Page 108: Manual Carman Scan Vg

108

CARMANSCAN VG Manual

XIV. Oscilloscope

: Displays the ignition waveforms of the entire cylinders

in Parade form.

Fig. XIV-34 Screen Setting – Series Mode

: Displays the ignition waveform of each cylinder.

Fig. XIV-35 Screen Setting – Cylinder Mode TIPS) To select another cylinder for display, press the “Return” icon (F6)

and then select “Cylinder” The individual Cylinder numbers will be displayed

for selection.

Page 109: Manual Carman Scan Vg

109

CARMANSCAN VG Manual

XIV. Oscilloscope

: Displays the overall trend of ignition waveform values.

Fig. XIV-36 Screen Settings – Trend Mode

: Tap on “PEAK VOLT”.

☞ Pressing this icon activates the peak voltage data pane on the right

side where the data change per cylinder is displayed.

: Tap on “DWELL”.

☞ Pressing this icon activates the dwell time data pane on the right

side where the data change per cylinder is displayed.

: Tap on “BURN VOLT”.

☞ Pressing this icon activates the burn-voltage data pane on the right

side where the data change per cylinder is displayed.

: Tap on “BURN TIME”.

☞ Pressing this icon activates the burn time data pane on the right side

where the data change per cylinder is displayed.

Page 110: Manual Carman Scan Vg

110

CARMANSCAN VG Manual

XIV. Oscilloscope

: Displays the ignition waveforms in a 3-dimentional

screen.

Fig. XIV-37 Screen Settings – 3D Mode Special Note: Lead Connections

1. Conventional Coil Vehicle.

- Connect the main Secondary ignition pickup lead to channel 2 and the

No 1 “trigger” pickup to channel 3.

Secondary pickup Trigger pickup

2. Distributor-less Ignition Coil Vehicle

- On DLI (Distributor-less ignition) vehicles with a waste spark system,

Connect the multi-lead set from the “Positive” firing cylinders to Channel 1

and the multi-lead set from the “Negative” firing cylinders to channel 2.

Connect the No 1 “trigger” pickup to channel 3.

Note: Ensure the word “Spark”

on the trigger pickup faces

towards the spark plug.

Page 111: Manual Carman Scan Vg

111

CARMANSCAN VG Manual

XIV. Oscilloscope

7. Comparison of a Normal Waveform and Misfire Waveform

Comparison of Waveforms in a Split Mode

Fig. XIV-38 Split Screen Normal Waveform

Fig. XIV-39 Split Screen Misfire Waveform

Page 112: Manual Carman Scan Vg

112

CARMANSCAN VG Manual

XIV. Oscilloscope

Comparison of Waveforms in a Series Mode

Fig. XIV-40 Series- Normal Waveform

Fig. XIV-41 Series- Misfire Waveform

Page 113: Manual Carman Scan Vg

113

CARMANSCAN VG Manual

XIV. Oscilloscope

Comparison of Waveforms in Cylinder Mode

Fig. XIV-42 Cylinder-Normal Waveform

Fig. XIV-43 Cylinder-Misfire Waveform

Page 114: Manual Carman Scan Vg

114

CARMANSCAN VG Manual

XIV. Oscilloscope

Comparison of Waveforms in a Trend Mode

Fig. XIV-44 Trend-Normal Waveform

Fig. XIV-45 Trend Actual Waveform

Page 115: Manual Carman Scan Vg

115

CARMANSCAN VG Manual

XIV. Oscilloscope

Comparison of 3D Waveforms

Fig. XIV-46 3D_Normal Waveform

Fig. XIV-47 3D_Misfire Waveform

Page 116: Manual Carman Scan Vg

116

CARMANSCAN VG Manual

XIV. Oscilloscope

8. Measurement of Waveform per Trouble Type - When you select a trouble type, the sensors and actuators related to the

trouble are selected automatically to enable oscilloscope measurement.

Fig. XIV-48 Waveform Measurement per Trouble

: Tap on “SAVE”.

☞ Selects the items to be tested in each channel, and changes the scope

measurement mode to suit. : Tap on “CANCEL”.

☞ Cancels all the settings, allowing you to make settings again.

Page 117: Manual Carman Scan Vg

117

CARMANSCAN VG Manual

XV. Meter & Simulator

1. Main Menu

- Meter and Simulation functions.

XV-1 Meter & Simulator

: Tap to measure voltage.

☞ Allows measurement of voltage via the multi-meter functions.

: Tap to measure current. ☞ Requires Optional high or low current clamp.

: Tap to measure frequency. ☞ Allows measurement of frequency via the multi-meter functions.

: Tap to measure pressure.

☞ Requires Optional pressure pickup.

: Tap on it to measure a duty. ☞ Allows measurement of duty cycle via the multi-meter functions.

Page 118: Manual Carman Scan Vg

118

CARMANSCAN VG Manual

XV. Meter & Simulator

: Tap to test an actuator. ☞ You can use this function to determine if an actuator is normal by

starting or stopping it via the in-built Actuator driver.

: Tap to measure resistance. ☞ Allows measurement of resistance via the multi-meter functions.

: Tap to output a voltage arbitrarily.

☞ Allows simulation of sensors by outputting a variable voltage.

For Example) Throttle position sensor, coolant temperature sensor etc.

: Tap to measure temperature.

☞ Requires Optional Thermocouple pickup

: Tap to output a frequency arbitrarily.

☞ Allows simulation of sensors by outputting a variable frequency, duty

cycle and voltage.

TIPS)

Measurements using the optional items such as current and temperature

probes will be described in the separate user manual for optional items.

Page 119: Manual Carman Scan Vg

119

CARMANSCAN VG Manual

XVI. Utility Box

1. Main Menu

- Using calculator, touch screen calibration and file explorer function.

Fig. XVI-1 Utility Box

: Tap to use the Calculator.

☞ This function includes a calculation and unit conversion of length, weight,

volume, and area.

: Tap to calibrate the Touch Screen.

☞ Executes a touch screen calibration program.

: Tap to select the File Explorer.

☞ Executes a file explorer function.

Page 120: Manual Carman Scan Vg

120

CARMANSCAN VG Manual

XVI. Utility Box

: Tap to select the Fix Bug File.

☞ You can delete simply defective or error files caused by program

update.

: Tap to select the VG Test.

☞ You can do self-test of overall scanner and scope functions..

Page 121: Manual Carman Scan Vg

121

CARMANSCAN VG Manual

XVI. Utility Box

2. Calculator

- Provides a general calculator and unit conversion function.

Fig. XVI-2 Calculator

1. Input data pane

- The data entered via the number panel is displayed.

2. Data input keys

- Can be used the same as a general calculator.

3. Unit setting pane

- You can select the unit of the number to be displayed on an input pane.

- If you select a unit, the result is converted to other units shown in the pane

(5) and displayed under a corresponding unit symbol.

4. Input result pane

- The entered number and unit are displayed here.

5. Unit conversion pane

- The entered number is converted to other units listed in this pane.

Page 122: Manual Carman Scan Vg

122

CARMANSCAN VG Manual

XVI. Utility Box

3. Touch Screen Calibration

- You can use this function to align the hitting point of a touch screen

accurately.

Fig. XVI-3 Touch Screen Calibration

1. Tap accurately on the center of the “cross” displayed on the screen.

2. After the calibration is completed, press “ENTER” button to save the

result, and return to Fig. XIV-1.

3. If the calibration is done incorrectly, press “ESC” to start a calibration

procedure again.

Page 123: Manual Carman Scan Vg

123

CARMANSCAN VG Manual

XVI. Utility Box

4. File Explorer

- You can use the file explorer to search or execute a file.

Fig. XVI-4 File Explorer

☞ You can use this function via a connection with a mouse and keyboard.

It is a windows environment, which operates just like that of a PC.

Page 124: Manual Carman Scan Vg

124

CARMANSCAN VG Manual

XVII. Program Download

1. Main Menu

- This function is used to download diagnosis programs and other application programs.

- You can check the data saved on the hard disk and internal flash memory.

Fig. XVII-1 Program Download

: Select a file on either list and then tap on Delete.

☞ Deletes the selected file.

: Select a file on the hard disk list, and tap on Download.

☞ Downloads the selected file from the hard disk to the internal memory.

: Select a file saved on the hard disk, and tap on Hard Inform.

☞ You can view the detailed information of the selected file.

: Select a file in internal memory, and tap on Internal Inform.

☞ You can view the detailed information of the selected file.

: Tap to download multiple files at a time.

☞ SELECT FILE LIST window is displayed.

: Select a file, and tap on Select.

☞ A selected file is added to a SELECT FILE LIST.

Page 125: Manual Carman Scan Vg

125

CARMANSCAN VG Manual

XVII. Program Download

2. Delete

1. Select a file to delete, and tap on the delete icon.

Fig. XVII-2 Delete

2. A deletion confirmation message is displayed.

- If you want to delete it, tap on OK icon.

- If not, tap on CANCEL icon.

Fig. XVII-3 Delete

Page 126: Manual Carman Scan Vg

126

CARMANSCAN VG Manual

XVII. Program Download

3. A message showing the completion of a file deletion is displayed.

- Tap on OK icon to complete it.

[ Fig. XVII-4 Delete ]

Page 127: Manual Carman Scan Vg

127

CARMANSCAN VG Manual

XVII. Program Download

3. Download

1. Select a file from the hard disk list, and tap on the download icon.

Fig. XVII-5 Download

2. A download confirmation message is displayed.

- If you want to download it, tap on OK icon.

- If not, tap on CANCEL icon.

Fig. XVII-6 Download

Page 128: Manual Carman Scan Vg

128

CARMANSCAN VG Manual

XVII. Program Download

3. Memory setting is started

Fig. XVII-7 Download

TIP)

Memory Setting?

Due to the characteristics of flash memory, the space necessary for download

of new data is cleared. Even if there is no data in flash memory, this procedure

is performed.

4. A program download is executed.

Fig. XVII-8 Download

Page 129: Manual Carman Scan Vg

129

CARMANSCAN VG Manual

XVII. Program Download

5. A message asking for program verification is displayed.

- If you want the verification, tap on OK icon.

- If not, tap on CANCEL icon.

Fig. XVII-9 Download File Verification

TIP)

What is the verification?

It is the function to check if the original file to download is the same as the file

downloaded to flash memory.

6. A download completion message is displayed.

- Check the name of a downloaded file, and tap on OK icon to complete the

down load procedure.

Fig. XVII-10 Download Completion

Page 130: Manual Carman Scan Vg

130

CARMANSCAN VG Manual

XVII. Program Download

4. Hard Disk Information

- You can check the information on the files saved on the hard disk.

Fig. XVII-11 Hard Info

5. Internal Information

- You can check the information on the files existing in the internal flash

memory.

Fig. XVII-12 Internal Information

Page 131: Manual Carman Scan Vg

131

CARMANSCAN VG Manual

XVII. Program Download

6. Select File List

- You can select and check the file to download or delete.

If you tap on this icon once, a select file list for the hard disk is displayed;

and if you tap on it once more, a select file list for the internal memory is

displayed.

[ Fig. XVII-13 Select File List ]

TIPS)

- Tapping on this icon displays a select file list for the hard disk and internal

memory alternately.

Page 132: Manual Carman Scan Vg

132

CARMANSCAN VG Manual

XVIII. Configuration Setting

1. Main Menu

- This is a function to test a key pat, check the system configuration

information, and change the product settings.

Fig. XVIII-1 Configuration Setting

: Tap to select the key function settings.

☞ You can change the left/.right layout of keys, and check if they are normal.

: Tap to select the system unit settings.

☞ You can change the units of data displayed by a program.

: Tap to select the Control Panel.

☞ It provides a function the same as a control panel of a computer.

Page 133: Manual Carman Scan Vg

133

CARMANSCAN VG Manual

XVIII. Configuration Setting

: Tap to select the battery settings.

☞ You can set the warning about remained battery power.

: Tap to select System Information.

☞ You can check the product’s lot number, serial number and program

version.

: Tap to select Other Setting.

☞ You can set options for whether the mouse pointer shows on the screen.

: Tap to select Graph Set.

☞ You can set graph and osilloscope screen.

Page 134: Manual Carman Scan Vg

134

CARMANSCAN VG Manual

XVIII. Configuration Setting

: You can change the Colour of Line for your better analysis

in case of being a lot of lines in the screen, which might

confuse you at various similar line.

[ 그림 XVIII-2 그래프 색상 설정 ]

: Tap to select Bottom.

☞ You can select the bottom colour of scnreen.

: Tap to select Grid 1.

☞ As you can see in the Picture XVIII-2, it makes you to analyze the data

precisely while dividing the box among ten.

You can change the color of the line of the horizontal axis using screen scale

configuration.(Which is not shown on the picture above.).

: Tap to select Grid 2

☞ You can change the color of the horizontal axis line on the screen.

Page 135: Manual Carman Scan Vg

135

CARMANSCAN VG Manual

XVIII. Configuration Setting

: Tap to select Center Grid.

☞ You can change the color of the vertical axis line on the screen.

: Tap to select Cursor.

☞ You can change the color of the cursor which the point of time is selected

by user.

: Tap to select CH1/8.

☞ You can select from Channel 1 to Channel 8.

: Tap to select CH Color.

☞ You can change the color of the selected channel.

: Tap to select OK.

☞ The selected item will be saved.

: Tap to select CANCEL.

☞ The selected item will be canceled.

: Tap to select Default 1.

☞ Setting-up as default 1 value.

: Tap to select Default 2.

☞ Setting-up as default 2 value.

Page 136: Manual Carman Scan Vg

136

CARMANSCAN VG Manual

XVIV. Carmanscan VG Printer Setting

1. Available Printers

Carmanscan VG is compatible with printers using HP PCL (Printer Control

Language) driver.

- You should check if a printer supports HP PCL driver, before you purchase.

☞ Recommended Printers

HP

Business Inkjet 1000

Photo Smart 7450

Samsung

MJC 8500

2. Setting

- You can set a HP PCL driver-supporting printer by connecting USB cable

with USB terminal in VG without any driver setting process.

☞ The following driver massage window may show up, when VG is connected

to printer first.

Then, press “OK” button, and go to next process.

VG recognizes a new printer successfully.

[ Fig. XVIV-1 Driver Massage ]

Page 137: Manual Carman Scan Vg

137

CARMANSCAN VG Manual

XVIV. Carmanscan VG Printer Setting

3. Using Printer functions

- In order to use printer function, you should capture a screen or bring

saved screen data.

- When you click capture button, the current screen will be captured. Then

following print message will show up.

You can print the captured screen immediately, or anytime you want after

saving captured screen.

4. Printer Setting

- As following Fig.XVIV-2, you can capture current screen with pressing

capture icon (NO.1).

- After capturing screen you want to print, a print message window asking

whether you print or cancel will show up.

[ Fig. XVIV-2 PRINT Massage ]

Page 138: Manual Carman Scan Vg

138

CARMANSCAN VG Manual

XVIV. Carmanscan VG Printer Setting

- If you click “Print” button, following window will show up.

- When you bring and print the saved screen-capture data, the same

window will show up.

☞ Printer setting window setting

[ Fig. XVIV-2 PRINT SETTING ] 1. Printer : Set PCL Inkjet (NO.1).

- This is default setting.

2. Port : Set LPT2 (NO.2).

- When a printer is connected, LPT2 is set.

3. Color Option Mode (NO.3)

- If you want black and white color print, check (“V”) next to the

“Draft Mode”.

- If you want color print, check (“V”) next to “Color”.

- If you check (“V”) to both, color print will be applied.

4. If all settings are done, click “OK” button. (NO.4)