2
ABSTRACTS S220 Heart, Lung and Circulation Abstracts 2009;18S:S1–S286 Results: CABG NO CABG p-Value Baseline data Age (years) 69.9 ± 10.2 65.8 ± 13.3 <.0001 Males (%) 76 75 <.0001 MI (%) 64.8 29.5 <.0001 Angina (%) 86.5 46.8 <.0001 CHF (%) 19.1 10.2 <.0001 DM (%) 31.6 23.6 <.0001 Renal Disease (%) 13.5 7.0 <.0001 Diagnosis Mean GRACE risk score + SD 126.3 ± 33.1 127.2 ± 37.9 0.4 STEMI (%) 8.0 30.6 <.0001 NSTEMI (%) 30.5 33.1 UA (%) 44.6 24.6 Angiography (%) 49.2 63.5 <.0001 Conclusions: Although there were differences between the CABG and no CABG groups, the CABG group unexpectedly had a lower rate of coronary angiography compared with no CABG. This difference persisted even after adjustment for age, gender and diagnosis at presen- tation (odds ratio = 0.64 (CI 0.54–0.75). doi:10.1016/j.hlc.2009.05.543 498 MAJOR STENT DEFORMATION/PSEUDO FRACTURE OF 7 CROWN ENDEAVOR STENT: INCIDENCE AND CAUSATIVE FACTORS M.R. Pitney 1,2, , K.J. Pitney 3 , N. Jepson 1,2 , D. Friedman 1,2 , N. Dang 1 , J. Matthews 1,2 , R. Giles 1,2 1 Eastern Heart Clinic, Sydney Australia 2 Prince of Wales Hospital, Sydney, Australia 3 University of NSW, Sydney, Australia Introduction: This is the initial report of a unique com- plication of the 7 crown Endeavor stent (2.25–2.75 mm) whereby the post-dilation balloon catches and causes major stent deformation angiographically appearing as a large stent fracture (see figure). We sought to determine frequency and cause. The 7 crown stent has a single helix supporting backbone which improves flexibility but limits longitudinal strength. Methods: A retrospective analysis of all 7 crown Endeavor stents deployed at our institution. Bench testing was also performed by deploying and post-dilating stents in 2.5 mm tubing at a 50 mm diameter constant curve, then imaging with IVUS and optical scanning. Results: There were 7 cases of major stent deforma- tion/pseudo fracture representing an incidence of 1.0% (7/ 701), or 1.2% of stents that were post-dilated (7/575). Proce- dural variables increasing risk include tortuosity and the use of stiffer wires. In benchtop testing, balloon “catch” was reproducible at a frequency of 10–50% depending on technique. Factors increasing frequency included subop- timal stent deployment, stiffer wires, and slower speed of balloon advancement. Under worst case conditions (tip of the post-dilatation balloon came in contact with the stent opposite its supporting helix) balloon catch resulted in significant stent deformation 10% of the time. The compli- cation could not be replicated with 9 crown stents (double helix weld pattern). Conclusion: When post-dilation is performed, major stent disruption/pseudo fracture occurs with the 7 crown Endeavor in 1.2% of cases. Operators need to be aware of the complication and develop strategies to deal with it. doi:10.1016/j.hlc.2009.05.544 499 MANAGEMENT AND OUTCOMES OF EARLY STENT THROMBOSIS Rohan Gupta 1 , Patrick Diu 2 , Saissan Rajendran 1 , Maria Gonzalez 2 , Andrew Hopkins 1,2 , John French 1,2 , Craig Juergens 1,2 1 University of New South Wales, Sydney, NSW, Australia 2 Liverpool Hospital, Sydney, NSW, Australia Background: Patients who have stent thrombosis may be considered at higher risk of recurrent episodes, however the amount of risk requires clarification. Methods: To determine the management and outcomes of patients after their first episode of early stent thrombosis (0–30 days), we retrospectively analysed 45 patients who had an episode of early stent thrombosis (ST) at Liverpool hospital over the period 1998–2008 and underwent repeat percutaneous coronary intervention (PCI) as manage- ment. We evaluated procedural details, use of anti-platelet and anti-thrombotic therapy, and post-procedural man- agement. Patients were followed, for a median of 5.3 years, to assess the incidence of recurrent ST and MACE (com- posite of non-fatal myocardial infarction, coronary artery bypass grafting and cardiac death) after their second pro- cedure. Results: The median time for ST after first PCI was 6 days (IQR 3–11 days); 34 presented with STEMI, 6 NSTEMI and 5 UA. 39 patients (87%) were administered glycoprotein IIb/IIIa inhibitors (GPI). 37 patients were restented and 8 received balloon angioplasty alone. 13 patients (29%) had a recurrent ST; 5 received a third PCI; 5 underwent CABG; and 3 treated medically. Of the 5 undergoing a third PCI, 2 had another ST requiring CABG. After the second pro- cedure there were 32 MACEs (7 deaths (16%); 17 non-fatal MIs (38%); 9 CABGs (20%)); 10 patients had more than 1 event. Conclusion: ST is largely managed by restenting of the target vessel and GPIs. ST is associated with a high degree

Management and outcomes of early stent thrombosis

Embed Size (px)

Citation preview

Page 1: Management and outcomes of early stent thrombosis

AB

ST

RA

CT

S

S220 Heart, Lung and CirculationAbstracts 2009;18S:S1–S286

Results:

CABG NO CABG p-Value

Baseline dataAge (years) 69.9 ± 10.2 65.8 ± 13.3 <.0001Males (%) 76 75 <.0001MI (%) 64.8 29.5 <.0001Angina (%) 86.5 46.8 <.0001CHF (%) 19.1 10.2 <.0001DM (%) 31.6 23.6 <.0001Renal Disease (%) 13.5 7.0 <.0001

DiagnosisMean GRACE risk

score + SD126.3 ± 33.1 127.2 ± 37.9 0.4

STEMI (%) 8.0 30.6 <.0001NSTEMI (%) 30.5 33.1UA (%) 44.6 24.6Angiography (%) 49.2 63.5 <.0001

Conclusions: Although there were differences betweenthe CABG and no CABG groups, the CABG groupunexpectedly had a lower rate of coronary angiographycompared with no CABG. This difference persisted evenafter adjustment for age, gender and diagnosis at presen-tation (odds ratio = 0.64 (CI 0.54–0.75).

doi:10.1016/j.hlc.2009.05.543

498MAJOR STENT DEFORMATION/PSEUDO FRACTUREOF 7 CROWN ENDEAVOR STENT: INCIDENCE ANDCAUSATIVE FACTORS

M.R. Pitney 1,2,, K.J. Pitney 3, N. Jepson 1,2, D.

Friedman 1,2, N. Dang 1, J. Matthews 1,2, R. Giles 1,2

1 Eastern Heart Clinic, Sydney Australia2 Prince of Wales Hospital, Sydney, Australia3 University of NSW, Sydney, Australia

Introduction: This is the initial report of a unique com-plication of the 7 crown Endeavor stent (2.25–2.75 mm)whereby the post-dilation balloon catches and causesmajor stent deformation angiographically appearing as alarge stent fracture (see figure). We sought to determinefrequency and cause. The 7 crown stent has a single helixsupporting backbone which improves flexibility but limitslongitudinal strength.

Methods: A retrospective analysis of all 7 crownEndeavor stents deployed at our institution. Bench testingwas also performed by deploying and post-dilating stentsin 2.5 mm tubing at a 50 mm diameter constant curve, thenimaging with IVUS and optical scanning.

Results: There were 7 cases of major stent deforma-tion/pseudo fracture representing an incidence of 1.0% (7/701), or 1.2% of stents that were post-dilated (7/575). Proce-dural variables increasing risk include tortuosity and theuse of stiffer wires. In benchtop testing, balloon “catch”was reproducible at a frequency of 10–50% depending ontechnique. Factors increasing frequency included subop-timal stent deployment, stiffer wires, and slower speed ofballoon advancement. Under worst case conditions (tip ofthe post-dilatation balloon came in contact with the stentopposite its supporting helix) balloon catch resulted insignificant stent deformation 10% of the time. The compli-cation could not be replicated with 9 crown stents (doublehelix weld pattern).

Conclusion: When post-dilation is performed, majorstent disruption/pseudo fracture occurs with the 7 crownEndeavor in 1.2% of cases. Operators need to be aware ofthe complication and develop strategies to deal with it.

doi:10.1016/j.hlc.2009.05.544

499MANAGEMENT AND OUTCOMES OF EARLY STENTTHROMBOSIS

Rohan Gupta 1, Patrick Diu 2, Saissan Rajendran 1, MariaGonzalez 2, Andrew Hopkins 1,2, John French 1,2, CraigJuergens 1,2

1 University of New South Wales, Sydney, NSW, Australia2 Liverpool Hospital, Sydney, NSW, Australia

Background: Patients who have stent thrombosis may beconsidered at higher risk of recurrent episodes, howeverthe amount of risk requires clarification.

Methods: To determine the management and outcomesof patients after their first episode of early stent thrombosis(0–30 days), we retrospectively analysed 45 patients whohad an episode of early stent thrombosis (ST) at Liverpoolhospital over the period 1998–2008 and underwent repeatpercutaneous coronary intervention (PCI) as manage-ment. We evaluated procedural details, use of anti-plateletand anti-thrombotic therapy, and post-procedural man-agement. Patients were followed, for a median of 5.3 years,to assess the incidence of recurrent ST and MACE (com-posite of non-fatal myocardial infarction, coronary arterybypass grafting and cardiac death) after their second pro-cedure.

Results: The median time for ST after first PCI was 6 days(IQR 3–11 days); 34 presented with STEMI, 6 NSTEMI and5 UA. 39 patients (87%) were administered glycoproteinIIb/IIIa inhibitors (GPI). 37 patients were restented and 8received balloon angioplasty alone. 13 patients (29%) hada recurrent ST; 5 received a third PCI; 5 underwent CABG;and 3 treated medically. Of the 5 undergoing a third PCI,2 had another ST requiring CABG. After the second pro-cedure there were 32 MACEs (7 deaths (16%); 17 non-fatalMIs (38%); 9 CABGs (20%)); 10 patients had more than 1event.

Conclusion: ST is largely managed by restenting of thetarget vessel and GPIs. ST is associated with a high degree

Page 2: Management and outcomes of early stent thrombosis

AB

ST

RA

CT

S

Heart, Lung and Circulation S2212009;18S:S1–S286 Abstracts

of morbidity and mortality and there are high rates ofrecurrent episodes.

doi:10.1016/j.hlc.2009.05.545

500MEASUREMENT OF THE INDEX OF MICRO-CIRCULATORY RESISTANCE PREDICTSPERI-PERCUTANEOUS CORONARY INTERVENTIONMYOCARDIAL INFARCTION

A.S.C. Yong 1,2,, C. Chawantanpipat 1, M.K.C. Ng 1

1 Cardiology Department, Royal Prince Alfred Hospital,Sydney, Australia2 Cardiology Department, Concord Repatriation General Hos-pital, Sydney, Australia

Background: The index of microcirculatory resis-tance (IMR) is an invasive pressure–temperature sensorwire derived measurement, performed during cardiaccatheterization that provides a specific quantitativeassessment of coronary microvasculature status. We haverecently shown that IMR predicts infarct size in the pri-mary percutaneous coronary intervention (PCI) setting.We now investigate the use of IMR in predicting peri-PCImyocardial infarction (PMI).

Methods: N = 14 consecutive patients undergoing elec-tive PCI of a single lesion were recruited. Thepressure–temperature sensor wire (RADI, Uppsala) wasused for PCI and physiological measurements. Mea-surements obtained included mean transit time at rest(TmnR), hyperemic Tmn (TmnH), hyperemic proxi-mal pressure (Pa), hyperemic distal pressure (Pd) andwedge pressure (Pw). Hyperemia was induced by adeno-sine infusion (140 mcg/kg/min). Coronary flow reserve(CFR = TmnR/TmnH) and IMR corrected for collateralflow (PaXTmnHX[Pd − Pw]/[Pa − Pw]) were calculated preand post-PCI. Troponin T levels were measured before and1 day post-PCI. PMI was defined as post-procedural tro-ponin T >0.03 �g/L or a post-procedural rise in patientswith downward trending pre-PCI troponin levels.

Results: All patients had normal or downward trend-ing pre-PCI troponin T levels. Three (21.4%) patientshad a PMI. Mean ± SD of procedural IMR change was5.5 ± 14. Using an IMR rise of >5 as a cut-off, IMR elevationcould predict PMI (sensitivity = 100%, specificity = 73%,area under ROC curve = 0.90). CFR was not predictive ofPMI.

Conclusions: Peri-procedural IMR elevation is predic-tive of PMI. IMR is easily assessed and provides an early,on-table detection method for PMI. Such a method facili-tates the development of therapeutic strategies and couldhelp in post-procedural management decisions.

doi:10.1016/j.hlc.2009.05.546

501MYOCARDIAL INJURY FOLLOWING CORONARYARTERY SURGERY VERSUS ANGIOPLASTY(MICASA): A RANDOMIZED TRIAL USINGBIOCHEMICAL MARKERS AND MAGNETICRESONANCE IMAGING

William van Gaal 1,2,3,, Jayanth Arnold 3, Luca Testa 3,Theo Karamitsos 3, Chris Lim 3, Francis Ponnuthurai 1,3,Joseph Selvanayagem 3, Steve Westaby 3, StefanNeubauer 3, Adrian Banning 3

1 Northern Health, Epping, Australia2 University of Melbourne, Melbourne, Australia3 John Radcliffe Hospital, Oxford, UK

Background: The frequency of peri-procedural myocar-dial injury defined by late gadolinium enhancementon magnetic resonance imaging (MRI) following per-cutaneous coronary intervention (PCI) and coronaryartery bypass grafting (CABG) have not been directlycompared. Furthermore, peri-procedural necrosis andmyocardial infarction (MI) were recently redefined by theESC/AHA/WHF. We sought to compare the frequencyof Troponin I and MRI defined injury following PCI andCABG.

Methods: Single centre randomized trial. Patients with2 or 3 vessel CAD and/or left main disease were eligible.

Results: Of 80 patients enrolled, 40 underwent PCIand 39 underwent CABG (1 death prior). Two PCI and 7CABG patients had incomplete MRI evaluation (5 claus-trophobia, 3 renal impairment, 1 image quality), and 4CABG patients had incomplete biomarkers. Mean syn-tax scores were 23.6 ± 7.6 vs. 22.1 ± 6.8 (p = 0.34) and meanEuro scores 1.85 vs. 2.31 (p = 0.21) for PCI and CABGrespectively. Following PCI, 6/38 (15.8%) patients had lategadolinium enhancement, compared with 9/32 (28.1%)following CABG (p = 0.25). Using the new universal defini-tions, necrosis occurred in 30/40 (75.0%) PCI patients and35/35 (100%) CABG patients (p = 0.001), and MI occurred in30/40 (75.0%) PCI patients and 9/32 (28.1%) CABG patients(p = 0.0001). Only 6/30 (20.0%) PCI patients who met thenew definition of peri-procedural MI had late enhance-ment on MRI.

Conclusions: The incidence of MRI defined infarctiondid not differ between groups. According to the newdefinition, necrosis was significantly lower following PCIcompared with CABG. The new definition of PCI relatedMI overestimates the incidence MI compared with MRIdefined infarction.

doi:10.1016/j.hlc.2009.05.547