71
Kewberg Cables & Braids (Pty) Ltd. 9 Clarke Street Alrode, Alberton 1450 Johannesburg, South Africa Phone: +27 (0 11) 908 5165 Fax: +27 (0 11) 864 6812 Fax: +27 (0 11) 908 1261 E-mail: [email protected] [email protected] Products Catalogue

Main Product Publication 1Vkewberg.com/Products Catalogue 2010.pdf · 2015-09-18 · Kewberg Cables & Braids (Pty) Ltd. 9 Clarke Street ... abrasion resistant and mechanically strengthened

  • Upload
    lethuan

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

Kewberg Cables & Braids (Pty) Ltd.

9 Clarke Street

Alrode, Alberton

1450

Johannesburg, South Africa

Phone: +27 (0 11) 908 5165

Fax: +27 (0 11) 864 6812

Fax: +27 (0 11) 908 1261

E-mail: [email protected]

[email protected]

Products Catalogue

Kewberg Cables, a subsidiary of the TransCentury Group, is a leading manufacturer of

cables. The company’s customer base includes power supply authorities, railway and

transport organisations, municipalities, and companies in industries such as petrochemi-

cal, mining, wholesale, industrial, construction and domestic building. The company

manufactures and sells a wide range of state of the art products with customer specific

adaptation, design capabilities and full technical back-up service.

Kewberg Cables prides its self on its ability to identify and satisfy customer needs through

development of innovative products; unique, cost effective cable solutions for a wide

range of industries

Technology focus

Kewberg Cables pursues ongoing technology developments through active association

with its local and overseas affiliates. This has enabled the company to remain at the

forefront of technology.

The company has been recognised as a pioneer and leader in specialised cable ad-

vancements in South Africa. Kewberg serves on a number of South African Bureau of

Standards Committees.

Quality focus

Kewberg Cables is a fore runner in the industry with regard to quality.

The manufacturing, quality assurance, are of a world-class standard. In fact the com-

pany has been awarded ISO 9001 compliance certificate.

These quality assurance systems are applied to all the phase of manufacturing process,

likewise ensure the perfect operation of the cable, in accordance with the purpose for

which it was developed.

Customer focus

Customer satisfaction through attention and service are the key pillars on which the com-

petitive strategy of Kewberg Cables is based. We aim at a level of agility and flexibility of

our factory to enable the speedy manufacture of cables that are not kept in stock

3

5

1 Instrumentation And Control Cable

A wide range of paired and multicore cables which are XLPE insulated .

the cables are screened with an aluminium/mylar tape which gives

protection against interference .

Paired cables can be overall or individually and overall screened .

multicore cables are overall screened .

The standard range is sheathed with flame retardant pvc but can also

be done with low halogen and halogen free compounds .

The whole range can be done in steel wire armoured , APL, FR or unar-

moured .

2 Power Cables

A range of power cables from 2 cores - 37 cores are manufactured to sans

1507 .

These cables are sheathed with flame retardant , low halogen and

halogen free compounds . Various sizes of cabtyre are also manufactured .

3 Pull-Cord Cables

These cables are primarily used for conveyer belt systems on mines .

A wide variety of conductor configurations to suit customer

requirements are protected with a brass plated steel braid , offering

a high tensile , abrasion resistant and mechanically strengthened cable .

4 Cap Lamp Cable

Kewberg cables is the sole manufacture of cap lamp cable in South Africa .

the cables are used on miners cap lamps and are super flexible and

chemical , oil , and abrasion resistant .

5 Security Cables

These cables are used for alarm and burglar detection systems . Kewberg

manufactures a wide range of solid and stranded communication cables

in white , brown and black . Ripcords in various sizes and colours are also

supplied .

6 Blasting Wire

Blasting wire is manufactured specifically for detonation systems used

in the mining industry . These cables are manufactured in various sizes and

colours .

7 Defence Standard Cable

Manufactured to defence standard 61/12 part 4 and 5 . These cables are

supplied in multicore and paired constructions with foil or braid screen .

8 Airfield Lighting Cable .

Airfield lighting cable is used exclusively for the lighting of runways in

commercial and military airports .

9 Specialised Cables

Kewberg cables also manufactures a wide range of specialised cables in

various constructions .

Conductors - plain or tinned copper either solid or multistrand .

Insulation - polyethylene , cross linked polyethylene ( XLPE ) and various

grades of PVC .

Screening - aluminium/mylar foil and plain or tin copper braid .

Sheathing materials - flame retardant , low halogen and halogen free pvc

as well as polyethylene , polyurethane and nitrile outer sheaths can be supplied .

Protection - cable can be protected with galvanised steel wire , galvanised

steel wire braid , brass plated steel wire braid or aluminium polyethylene

laminate ( APL-FR ) .

Our range of specialised cables include underfloor heating cable , speed

trap cable , microphone cable , telephone cables , fire alarm cable , seismic

cable , illumination cable and a variety of single core cables .

7

2| Control Cables

1| Instrumentation Cables

3| Defence Specification Cables

4| Power Cables

5| Mining Cables

6| Special Cables

Instrumentation

Cables

9

KEWBERG manufactures and supplies a wide range of Instrumentation cables, which are

made using superior raw materials. These Instrumentation Cables are extensively used in

data acquisition systems, process control and computer networking, public address sys-

tems and digital control, measuring & communication systems.

We manufacture and stock a comprehensive range of Screened Instrumentation Cables,

which are used in signalling systems, control and instrument circuits.

These Cables also report and monitor process variables ranging from transducers to en-

vironmental controls and computer inputs. Maximum rejection of electromagnetic noise is

achieved by twisting the insulated conductors. Twisting causes the noise to be cancelled

in adjacent sections of the wire.

Maximum electrostatic noise rejection is achieved by shielding the cable with aluminium

foil tape.

A minimum of 25% overlap of the shield ensures 100% coverage even when the cable is

flexed. The drain wire under the shield provides continuous low resistance path to ground

and simplified hook-up at grounding terminals.

These Cables can also be provided with aluminium polyethylene laminate (APL) and steel

wire armouring (SWA).

Ease of installation is another major benefit of these Cables. Individual cores, pairs, tri-

ads or quads are colour coded and or number printed.

A pair of Communication Wires can also be provided. The Cables are available in a wide

range of insulation and jacket materials, the most popular being PVC, Polyethylene, FR

PVC, LHcL PVC or HFFR PVC.

Construction

Conductor

Bare (plain) or tinned electrolytic annealed copper conductor. Solid, stranded or flexible.

Insulation

Either XLPE, PVC or PE insulation in accordance with SABS 1411 as required.

Twisting and Laying

Required numbers of cores are laid up in case of multi-core core cables. Individual pairs, triads or

quads are formed by uniformly twisting the insulated cores with required lay lengths, prior to laying.

Core Identification

Cores can be colour coded or number printed for easy identification. In case of multi pair cables

both cores in each pair is alpha numerically at short intervals, individual screens are also printed.

Overall Screen

After final lay up of the complete cable an overall screen of aluminium-polyester tape is applied

along with 0.5 sqmm multi stranded annealed tinned copper (ATC) drain wire in continuous electrical

contact with aluminium side of the tape.

Individual & Overall Screen

Individual pairs, triads or quads are screened by aluminium-polyester tape along with 0.5 sqmm an-

nealed tin copper drain wire and overall screened by aluminium-polyester tape as mentioned above.

Tinned copper braid screening can also be used for individual screen.

In case of individually screened cables for critical applications an extruded isolation sheath can also

be provided over the individual screens.

Assembly Binder

After final assembly PVC or PE is provided as required to act as a binder as well as bedding for the

outer screening in all cables.

Armour

Galvanized steel wire or a flame retardant aluminium polyethylene laminate.

Inner & Outer Sheath

PVC, HFFR, LHCL PVC or FR PE sheath can be provided. U.V stabilized Polyethylene sheath can

also be provided for hazardous areas. A blue colour outer sheath for intrinsically safe areas can be

provided on request. A communication wires can be provided if desired.

Rip Cord

To simplify jacket removal, high tensile strength nylon Rip Cord is provided over laid up of pairs/

triads/quads below the outer sheath in case of unarmoured cable or below the Inner Sheath in case

of armoured Cable.

Quality Assurance

Quality Standards are built in every Kewberg Cables product. Our cables are subjected to a series of

required tests in our well-equipped laboratory. Besides the rigid tests and checks at every stage from

raw material through manufacturing stages and finally up to the finished product.

Being an ISO 9001: 2008 certified company, our quality management standards conform to highest

standards quality assurance practices.

11

Kewberg Cables & Braids (Pty) Ltd.

11

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Remark: - Cables of sizes not listed above is available on request

Instrumentation Cables

Multi-pairs—XLPE Insulated, Overall screened

E&OE

Applications & features

Plain annealed multi stranded coper conductor, cross linked polyethylene (XLPE) insu-

lated, cores twisted into pairs. The cores are black and white. Each core is alpha nu-

merically numbered. The cable is overall foil screened with a tinned copper drain wire. The sheath can be

flame retardant PVC low halogen or halogen free compound in black or coloured on request.

Construction

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km

Product CodeSize

(mm²)Pairs

Nominal OD(mm)

Minimumbendingradius(mm)

± Kg / KmCCG A2

Gland Size

Standarddrum length

(m)

Gross drumweight (Kg)

PAIRS

2500440 0.5 1 5.6 51 42 00 1000 912500450 0.5 2 8.9 81 88 0 1000 1532500460 0.5 4 10.6 96 128 0 1000 2032500480 0.5 8 13.3 121 212 1 1000 2992500490 0.5 12 15.8 143 282 2 500 2162500500 0.5 16 17.5 158 350 2 500 2502500520 0.5 24 20.3 183 491 2 500 3332500530 0.5 36 24.8 224 710 3 500 3752500550 1.0 1 6.4 58 60 00 1000 1092500560 1.0 2 10.8 98 131 0 1000 2062500570 1.0 4 12.4 112 183 1 1000 2582500580 1.0 8 16.1 146 315 2 1000 4772500590 1.0 12 18.7 169 428 2 500 2852500600 1.0 16 21.1 190 562 3 500 3682500620 1.0 24 24.1 217 772 3 300 3942500630 1.5 1 7.2 66 73 00 1000 1382500640 1.5 2 12.4 112 166 00 1000 2412500650 1.5 4 14.7 132 247 1 1000 3342500660 1.5 8 18.6 168 407 2 500 2752500670 1.5 12 22.1 199 582 3 500 4532500680 1.5 16 24.9 224 760 3 300 3902500700 1.5 24 28.4 256 1050 4 300 477

Kewberg Cables & Braids (Pty) Ltd.

12

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Triads—XLPE Insulated, Overall screened

E&OE

Applications & features

Plain annealed multi stranded coper conductor, cross linked polyethylene (XLPE) insu-

lated, cores twisted into triads. The cores are black, white and red. Each core is alpha

numerically numbered. The cable is overall foil screened with a tinned copper drain wire. The sheath can be

flame retardant PVC low halogen or halogen free compound in black or coloured on request.

Construction

Product CodeSize

(mm²)Triads

Nominal OD(mm)

Minimumbendingradius(mm)

± Kg / KmCCG A2

Gland Size

Standarddrum length

(m)

Gross drumweight (Kg)

TRIADS

2500990 0.5 1 5.9 54 51 00 1000 1002501010 0.5 4 11.8 107 164 1 1000 2392501020 0.5 8 15.7 141 280 2 1000 3672501030 0.5 12 18.8 169 383 2 500 2632501040 0.5 16 21.2 191 502 3 500 4132501055 0.5 24 26.5 239 726 3 300 3802501558 0.5 36 30.6 273 999 4 300 4622501060 1.0 1 6.8 61 72 00 1000 1212501080 1.0 4 14.3 129 255 1 1000 3422501090 1.0 8 18.3 167 428 2 500 2852501100 1.0 12 22.5 205 620 3 500 4722501110 1.0 16 25.4 229 809 3 300 4052501120 1.5 1 7.7 69 90 00 1000 1552501140 1.5 4 16.4 148 325 2 1000 4872501150 1.5 8 21.8 197 580 2 500 4522501160 1.5 12 26.8 241 841 3 300 414

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km

13

Kewberg Cables & Braids (Pty) Ltd.

13

It is used for transmission of analogue and

digital signals in process control systems. It

will be used for indoor and outdoor installation,

in dry and wet locations, on racks, and in con-

duits. Not allowed for direct connection to low

impedance source. It is not recommended for

direct burial.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Pairs—XLPE Insulated, Individual and Overall screened, Unarmoured

E&OE

Applications & features

Plain annealed multi stranded copper conductor, cross-linked polyethylene (XLPE)

insulated. Cores twisted into pairs. Each pair is foil screened with it ’s own tin copper

drain wire. For each pair, the cores are black and white. Each core and all screens are alpha numerically

numbered. The cable is overall foil screened with tinned copper drain wire. The sheath can be flame retar-

dant PVC low halogen or halogen free compound in black or coloured on request.

Construction

Product CodeSize

(mm²)Pairs

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Gross drumweight (Kg)

PAIRS

2500720 0.5 2 9.7 87 109 0 1000 1742500730 0.5 4 11.0 99 159 0 1000 2342500740 0.5 8 14.3 130 273 1 1000 3482500750 0.5 12 16.9 152 347 2 500 2492500760 0.5 16 19.4 175 458 2 500 3162500780 0.5 24 22.9 207 627 3 500 4782500790 0.5 36 27.6 249 907 4 500 698

2500810 1.0 2 11.1 101 148 0 1000 2232500820 1.0 4 12.8 115 213 1 1000 2882500840 1.0 8 16.7 151 377 2 1000 5392500860 1.0 12 20.2 182 544 2 500 3592500870 1.0 16 22.9 206 691 3 500 5082500890 1.0 24 27.4 247 998 4 500 743

2500920 1.5 2 12.7 115 183 1 1000 2582500930 1.5 4 15.0 136 297 2 1000 3842500940 1.5 8 19.7 178 494 2 500 3342500950 1.5 12 23.3 210 685 3 500 5052500960 1.5 16 26.8 242 903 4 300 4332500980 1.5 24 32.2 290 1305 4 300 554

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km

Kewberg Cables & Braids (Pty) Ltd.

14

It is used for transmission of analogue and

digital signals in process control systems. It

will be used for indoor and outdoor installa-

tion, in dry and wet locations, on racks, and

in conduits. Not allowed for direct connection

to low impedance source. It is not recom-

mended for direct burial.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Triads—XLPE Insulated, Individual and Overall screened, Unarmoured

E&OE

Applications & features

Plain annealed multi stranded copper conductor, cross-linked polyethylene (XLPE)

insulated. Cores twisted into triads. Each triad is foil screened with it ’s own tin copper

drain wire. The cores for the triads are black, white and red. Each core and all screens are alpha numeri-

cally numbered. The cable is overall foil screened with tinned copper drain wire. The sheath can be flame

retardant PVC low halogen or halogen free compound in black or coloured on request.

Construction

Product CodeSize

(mm²)Triads

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Gross drumweight (Kg)

TRIADS

2501180 0.5 4 12.2 110 189 1 1000 2642501190 0.5 8 16.2 146 330 2 1000 4922501210 0.5 12 19.8 179 479 2 500 3272501220 0.5 16 22.0 198 599 3 500 4622501230 0.5 24 27.5 248 872 4 300 4242501235 0.5 36 32.1 286 1248 4 300 536

2501250 1.0 4 14.7 132 286 2 1000 3732501260 1.0 8 19.2 175 509 2 500 3422501270 1.0 12 23.3 210 712 3 500 5182501280 1.0 16 26.1 237 931 3 300 441

2501320 1.5 4 16.8 152 348 2 1000 5102501330 1.5 8 22.3 202 645 3 500 4852501340 1.5 12 27.4 247 929 4 300 441

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km

15

Kewberg Cables & Braids (Pty) Ltd.

15

It is used for transmission of analogue and

digital signals in process control systems. It

will be used for indoor and outdoor installa-

tion, in dry and wet locations, on racks, and

in conduits. Not allowed for direct connection

to low impedance source. It is recommended

for direct burial.

Remark: - Cables of sizes not listed above is available on request

Instrumentation Cables

Multi-Pairs—XLPE Insulated, Overall screened , Steel Wire armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XPLE)

insulated, cores twisted into pairs. For paired cable the cores are black and white.

Each core is alpha numerically numbered. The cable is overall foil screened with a tinned copper drain wire.

The cable is supplied with a bedding sheath and is armoured with galvanised steel wire for protection. The

sheath can be flame retardant PVC, low halogen or halogen free compound in black or coloured on request.

Construction

Product CodeSize

(mm²)Pairs

Nominal OD(mm)

Minimumbending ra-

dius (mm)

± Kg / KmCCG BW

Gland Size

Standarddrum length

(m)

Gross drumweight (Kg)

PAIRS

2503150 0.5 1 10.5 106 249 0 1000 3242503160 0.5 2 13.8 139 394 0 1000 4812503170 0.5 4 15.5 155 486 0 1000 5732503190 0.5 8 18.6 187 651 1 1000 7972503200 0.5 12 21.1 212 810 2 500 5672503210 0.5 16 22.8 228 930 2 500 6272503230 0.5 24 26.3 263 1323 2 500 9062503235 0.5 32 29.3 294 1589 3 500 10392503240 0.5 36 32.0 320 1903 3 300 733

2503260 1.0 1 11.3 114 290 0 1000 3652503270 1.0 2 15.7 158 489 0 1000 5762503280 1.0 4 17.3 174 589 1 1000 7512503290 1.0 8 21.4 215 857 2 1000 10032503300 1.0 12 24.7 247 1199 2 500 7622503310 1.0 16 27.1 271 1418 3 500 9532503330 1.0 24 31.3 313 1986 3 300 758

2503340 1.5 1 12.1 122 329 0 1000 4042503350 1.5 2 17.3 173 572 1 1000 7342503360 1.5 4 20.0 200 738 2 1000 8842503370 1.5 8 24.6 247 1177 2 500 7512503380 1.5 12 28.5 285 1510 3 500 9992503390 1.5 16 32.1 321 2009 3 300 7652503410 1.5 24 35.6 357 2448 4 300 978

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREA RESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km

Kewberg Cables & Braids (Pty) Ltd.

16

It is used for transmission of analogue and

digital signals in process control systems. It

will be used for indoor and outdoor installa-

tion, in dry and wet locations, on racks, and

in conduits. Not allowed for direct connection

to low impedance source. It is recommended

for direct burial.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Triads—XLPE Insulated, Overall screened , Steel Wire armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XPLE) in-

sulated, cores twisted into triads. For triad cable the cores are black, white and red.

Each core is alpha numerically numbered. The cable is overall foil screened with a tinned copper drain wire.

The cable is supplied with a bedding sheath and is armoured with galvanised steel wire for protection. The

sheath can be flame retardant PVC, low halogen or halogen free compound in black or coloured on request.

Construction

Product CodeSize

(mm²)Triads

Nominal OD(mm)

Minimumbending ra-

dius (mm)

± Kg / KmCCG BW

Gland Size

Standarddrum length

(m)

Gross drumweight (Kg)

TRIADS

2503680 0.5 1 10.8 109 269 0 1000 344

2503700 0.5 4 16.7 168 557 1 1000 719

2503710 0.5 8 21.0 210 808 2 1000 954

2503720 0.5 12 24.8 248 1150 2 500 737

2503730 0.5 16 27.2 272 1371 3 500 930

2503745 0.5 24 33.7 337 2041 4 300 856

2503748 0.5 36 37.8 375 2499 4 300 994

2503750 1.0 1 11.7 117 316 0 1000 391

2503770 1.0 4 19.6 196 733 2 1000 820

2503780 1.0 8 24.3 245 1179 2 500 752

2503790 1.0 12 28.9 291 1565 3 500 1027

2503800 1.0 16 32.6 326 2086 3 300 788

2503810 1.5 1 12.6 126 358 0 1000 433

2503830 1.5 4 21.7 218 868 2 1000 1014

2503840 1.5 8 28.2 283 1505 3 500 997

2503850 1.5 12 34.0 340 2166 4 300 894

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREA RESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km

17

Kewberg Cables & Braids (Pty) Ltd.

17

It is used for transmission of analogue and

digital signals in process control systems. It will

be used for indoor and outdoor installation, in

dry and wet locations, on racks, and in con-

duits. Not allowed for direct connection to low

impedance source. It is recommended for di-

rect burial.

Remark: - Cables of sizes not listed above is available on request

Instrumentation Cables

Multi-Pairs—XLPE Insulated, Individual and Overall screened , Steel Wire armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insu-

lated. Cores twisted into pairs. Each pair is foil screened with it ’s own tin copper drain

wire. For paired cables the cores are black and white. Each core and all screens are alpha numerically num-

bered. The cable is overall foil screened with a tinned copper drain wire. The cable is supplied with a bedding

sheath and is armoured with galvanised steel wire armour for protection. The sheath can be flame retardant

PVC low halogen or halogen free compound in black or coloured on request.

Construction

Product CodeSize

(mm²)Pairs

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Grossdrum

weight(Kg)

PAIRS

2503430 0.5 2 14.6 146.0 439 0 1000 526

2503440 0.5 4 15.9 159.0 527 0 1000 614

2503450 0.5 8 19.6 197.0 761 2 1000 907

2503460 0.5 12 22.2 222.0 902 2 500 613

2503470 0.5 16 25.4 255.0 1267 2 500 878

2503480 0.5 24 29.3 293.0 1597 3 500 1043

2503485 0.5 32 33.3 334.0 2114 3 500 878

2503500 0.5 36 34.8 349.0 2268 4 300 924

2503520 1.0 2 16.0 161.0 517 3 1000 679

2503530 1.0 4 18.1 181.0 651 1 1000 797

2503540 1.0 8 21.4 215.0 934 2 1000 1080

2503550 1.0 12 26.2 262.0 1376 2 500 932

2503560 1.0 16 29.3 293.0 1644 3 500 1066

2503580 1.0 24 34.6 347.0 2356 4 300 951

2503350 1.5 2 18.0 180.0 620 1 1000 782

2503360 1.5 4 20.3 204.0 784 2 1000 930

2503370 1.5 8 25.7 257.0 1305 2 500 897

2503380 1.5 12 30.5 305.0 1863 3 500 1176

2503390 1.5 16 33.3 334.0 2228 4 300 912

2503410 1.5 24 39.8 339.0 2928 4 300 1170

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km

Kewberg Cables & Braids (Pty) Ltd.

18

It is used for transmission of analogue and

digital signals in process control systems. It will

be used for indoor and outdoor installation, in

dry and wet locations, on racks, and in con-

duits. Not allowed for direct connection to low

impedance source. It is recommended for di-

rect burial.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Triads—XLPE Insulated, Individual and Overall screened , Steel Wire armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insu-

lated. Cores twisted into triads. Each triad is foil screened with it ’s own tin copper drain

wire. For triad cables the cores are black, white and red. Each core and all screens are alpha numerically

numbered. The cable is overall foil screened with a tinned copper drain wire. The cable is supplied with a

bedding sheath and is armoured with galvanised steel wire armour for protection. The sheath can be flame

retardant PVC low halogen or halogen free compound in black or coloured on request.

Construction

Product CodeSize

(mm²)Triads

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Gross drumweight (Kg)

TRIADS

2503870 0.5 4 17.1 172.0 594 1 1000 669

2503880 0.5 8 21.5 215.0 870 2 1000 1016

2503900 0.5 12 25.8 259.0 1292 2 500 890

2503910 0.5 16 28.4 284.0 1526 3 500 1025

2503920 0.5 24 34.7 347.0 2231 4 300 914

2503925 0.5 36 39.7 394.0 2838 4 300 1143

2503940 1.0 4 20.0 200.0 777 2 1000 923

2503950 1.0 8 25.2 254.0 1301 2 500 894

2503960 1.0 12 30.5 306.0 1892 3 500 1190

2503970 1.0 16 33.5 336.0 2250 4 300 919

2504010 1.5 4 22.1 221.0 911 2 1000 1155

2504020 1.5 8 28.7 288.0 1586 3 500 1037

2504030 1.5 12 34.6 347.0 2288 4 300 930

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km

19

Kewberg Cables & Braids (Pty) Ltd.

19

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

The flame retardant sheath provides an excel-

lent water barrier and high chemical and abra-

sion resistant qualities.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Pairs—XLPE Insulated, Overall screened, APL / FR armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insu-

lated, cores twisted into pairs. For paired cable the cores are black and white. Each core is

alpha numerically numbered. The cable is overall foil screened with a tinned copper drain wire. The cable is

supplied with a bedding sheath and a flame retardant UV aluminium polyethylene laminate (APL/FR) for pro-

tection. A tinned copper wire is laid under the APL. The standard cable is black or coloured on request.

Construction

Product CodeSize

(mm²)Pairs

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Gross drumweight (Kg)

PAIRS2501810 0.5 1 9.4 85.0 90.0 0-20s 1000 1552501820 0.5 2 12.7 115.0 153.0 1-20 1000 2282501830 0.5 4 14.4 130.0 203.0 1-20 1000 2902501840 0.5 8 17.1 155.0 287.0 2-25 1000 4492501845 0.5 12 20.0 181.0 394.0 2-25 500 2842501850 0.5 16 21.7 195.0 471.0 3-32 500 3982501870 0.5 24 24.5 221.0 629.0 3-32 500 4772501880 0.5 36 29.4 265.0 772.0 4-40 300 429

2501900 1.0 1 10.2 92.0 111.0 0-20s 1000 1862501910 1.0 2 14.6 132.0 205.0 1-20 or 3-30 1000 2922501920 1.0 4 16.2 146.0 265.0 2-25 1000 4272501930 1.0 8 20.3 183.0 428.0 2-25 1000 5902501940 1.0 12 22.9 206.0 557.0 3-32 500 4412501950 1.0 16 25.3 228.0 706.0 3-32 500 4992501970 1.0 24 28.5 258.0 949.0 4-40 300 447

2501990 1.5 1 11.0 100.0 128.0 0-20s 1000 2032502000 1.5 2 16.2 146.0 248.0 2-25 1000 4102502010 1.5 4 18.4 166.0 354.0 2-25 1000 5002505020 1.5 8 22.8 206.0 535.0 3-32 500 4302502030 1.5 12 26.3 237.0 730.0 3-32 500 5112502040 1.5 16 29.4 265.0 943.0 4-40 300 4452502060 1.5 24 33.0 297.0 1256.0 4-40 300 539

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREA RESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km

Kewberg Cables & Braids (Pty) Ltd.

20

It is used for transmission of analogue and

digital signals in process control systems. It

will be used for indoor and outdoor installation,

in dry and wet locations, on racks, and in con-

duits. The FR sheath provides an excellent wa-

ter barrier and high chemical and abrasion re-

sistant qualities.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Triads—XLPE Insulated, Overall screened, APL / FR armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insu-

lated, cores twisted into triads. For triad cable the cores are black, white and red. Each

core is alpha numerically numbered. The cable is overall foil screened with a tinned copper drain wire. The ca-

ble is supplied with a bedding sheath and a flame retardant UV aluminium polyethylene laminate (APL/FR) for

protection. A tinned copper wire is laid under the APL. The standard cable is black or coloured on request.

Construction

Product CodeSize

(mm²)Triads

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Gross drumweight (Kg)

TRIADS

2502320 0.5 1 9.7 88.0 100.0 0-20s 1000 1652502340 0.5 4 15.6 141.0 244.0 2-25 1000 3312502350 0.5 8 19.8 179.0 392.0 2-25 1000 5382502360 0.5 12 23.0 207.0 512.0 3-32 500 4182502370 0.5 16 25.4 229.0 646.0 3-32 500 4692502374 0.5 24 31.1 280.0 919.0 4-40 300 4382502375 0.5 36 35.2 314.0 1217.0 5-50 300 609

2502380 1.0 1 10.5 95.0 126.0 0-20s 1000 2012502400 1.0 4 18.4 166.0 357.0 2-25 1000 5032502410 1.0 8 22.5 204.0 554.0 3-32 500 4392502420 1.0 12 26.7 242.0 773.0 4-40 500 5332502430 1.0 16 30.0 270.0 990.0 4-40 300 459

2502440 1.5 1 11.4 103.0 148.0 1-20 1000 2232502460 1.5 4 20.6 186.0 442.0 2-25 or 3-32 1000 5882502470 1.5 8 26.0 234.0 726.0 3-32 500 5092502480 1.5 12 31.4 283.0 1036.0 4-40 300 473

TECHNICAL INFORMATIONCONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREA RESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km

21

Kewberg Cables & Braids (Pty) Ltd.

21

It is used for transmission of analogue and

digital signals in process control systems. It will

be used for indoor and outdoor installation, in

dry and wet locations, on racks, and in con-

duits. The FR sheath provides an excellent wa-

ter barrier and high chemical and abrasion re-

sistant qualities.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Pairs—XLPE Insulated, Individual and Overall screened, APL / FR armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XPLE) in-

sulated. Cores twisted into pairs. Each pair is foil screened with it ’s own tin copper

drain wire. For paired cable the cores are black and white. Each core and all screens are alpha numerically

numbered. The cable is overall foil screened with tinned copper drain wire. The cable is supplied with a bed-

ding sheath and a flame retardant UV aluminium polyethylene laminate (APL/FR) for protection. A tin copper

drain wire is laid under the APL. The standard cable is black or coloured on requested.

Construction

Product CodeSize

(mm²)Pairs

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Grossdrum

weight(Kg)

Pairs2502070 0.5 2 13.4 121 177 1 1000 2642502080 0.5 4 14.8 133 234 2 1000 3212502090 0.5 8 18.5 167 378 2 1000 5242502100 0.5 12 20.7 187 465 3 500 3202502110 0.5 16 23.6 213 591 3 500 4582502130 0.5 24 27.1 244 781 4 500 5372502140 0.5 32 30.7 277 1016 4 500 7522502150 0.5 36 32.2 290 1070 4 300 498

2502160 1.0 2 14.9 135 224 2 1000 3112502170 1.0 4 16.5 149 297 2 1000 4592502180 1.0 8 20.9 189 496 3 1000 6422502190 1.0 12 24.4 220 682 3 500 5032502200 1.0 16 27.0 244 845 4 500 5692502220 1.0 24 32.0 289 1196 4 300 603

2502250 1.5 2 16.5 149 267 2 1000 4292502260 1.5 4 19.2 173 388 2 1000 5342502270 1.5 8 23.9 215 627 3 500 4762502280 1.5 12 27.5 248 839 4 500 6642502290 1.5 16 31.4 283 1099 4 300 4922502310 1.5 24 36.8 332 1534 5 300 704

TECHNICAL INFORMATIONCONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km

Kewberg Cables & Braids (Pty) Ltd.

22

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

The FR sheath provides an excellent water bar-

rier and high chemical and abrasion resistant

qualities.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Instrumentation Cables

Multi-Triads—XLPE Insulated, Individual and Overall screened, APL / FR armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XPLE) in-

sulated. Cores twisted into triads. Each triad is foil screened with it ’s own tin copper

drain wire. For triad cable the cores are black, white and red. Each core and all screens are alpha numerically

numbered. The cable is overall foil screened with tinned copper drain wire. The cable is supplied with a bed-

ding sheath and a flame retardant UV aluminium polyethylene laminate (APL/FR) for protection. A tin copper

drain wire is laid under the APL. The standard cable is black or coloured on requested.

Construction

Product CodeSize

(mm²)Triads

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Grossdrum

weight(Kg)

Triads2502500 0.5 4 16.0 144 271 2 1000 3582502510 0.5 8 20.4 184 444 2 1000 5902502520 0.5 12 24.0 217 614 3 500 4692502530 0.5 16 26.1 236 747 3 500 5202502540 0.5 24 32.0 289 1070 4 300 4832502551 0.5 36 36.7 328 1474 5 300 686

2502560 1.0 4 18.8 170 393 2 1000 5392502570 1.0 8 23.4 213 641 3 500 4832502580 1.0 12 27.5 248 868 4 500 6782502590 1.0 16 30.7 278 1126 4 300 500

2502610 1.5 4 21.0 189 472 3 1000 6182502620 1.5 8 26.5 239 787 3 500 5402502630 1.5 12 32.0 289 1126 4 300 500

TECHNICAL INFORMATION

CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL

AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE

0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km

1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km

1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km

23

Control Cables

Kewberg Cables & Braids (Pty) Ltd.

24

It is used for transmission of analogue and

digital signals in process control systems. It

will be used for indoor and outdoor installa-

tion, in dry and wet locations, on racks, and

in conduits. Not allowed for direct connection

to low impedance source, e.g. the public

mains electricity supply. It is not recom-

mended for direct burial.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.5mm2 39.00 Ω/km 300/500v

1.0mm2 19.50 Ω/km 600/1000v

1.5mm2 13.30 Ω/km 600/1000v

Product CodeSize

(mm²)Cores

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Gross drumweight (Kg)

300 / 500V

2500020 0.5 3 7.0 63 63 00 1000 112

2500030 0.5 4 7.8 70 77 00 1000 142

2500040 0.5 7 8.5 68 104 0 1000 183

2500050 0.5 12 10.9 87 160 0 1000 252

2500060 0.5 19 12.7 101 228 1 1000 347

2500070 0.5 24 15.1 120 305 2 500 235

0.5 27 15.9 127 336 2 500 248

600 / 1000V

2500100 1.0 3 7.8 71 86 00 1000 151

2500110 1.0 4 8.7 79 109 0 1000 353

2500140 1.0 7 10.6 96 172 0 1000 240

2500160 1.0 12 14.1 127 266 1 500 199

2500180 1.0 19 16.3 147 399 2 500 264

2500190 1.0 24 19.3 174 489 2 500 331

2500210 1.0 27 19.7 178 541 2 500 353

600 / 1000V

2500270 1.5 3 8.7 79 108 0 1000 173

2500280 1.5 4 10.1 91 145 0 1000 210

2500290 1.5 7 11.9 107 205 1 500 168

2500300 1.5 12 15.8 143 337 2 500 244

2500320 1.5 19 18.3 165 484 2 500 313

2500330 1.5 24 21.8 196 622 3 500 473

2500340 1.5 27 22.3 201 681 3 500 503

Control Cables

Multi-cores—XLPE Insulated, Overall screened , Unarmoured

E&OE

Applications & features

Electrical Data

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insulated, overall foil

screened with tinned copper drain wire . Colour coded cores up to 4 core , Thereafter white numbered cores

identified by black alpha numerical marking . Sheath can be flame retardant PVC low halogen or halogen free

compound in black or coloured on request .

Construction

25

Kewberg Cables & Braids (Pty) Ltd.

25

It is used for transmission of analogue and

digital signals in process control systems. It

will be used for indoor and outdoor installa-

tion, in dry and wet locations, on racks, and

in conduits. Not allowed for direct connection

to low impedance source, e.g. the public

mains electricity supply. It is recommended

for direct burial.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.5mm2 39.00 Ω/km 300/500v

1.0mm2 19.50 Ω/km 600/1000v

1.5mm2 13.30 Ω/km 600/1000v

Control Cables

Multi-cores—XLPE Insulated, Overall screened , Steel Wire armoured

E&OE

Applications & features

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insulated, overall foil

screened with tinned copper drain wire . Colour coded cores up to 4 core , Thereafter white numbered

cores identified by black alpha numerical marking . Cables supplied with a bedding sheath and galvanised

steel wire armour for protection. Sheath can be flame retardant PVC low halogen or halogen free compound

in black or coloured on request .

Construction

Product codeSize

(mm²)Cores

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Gross drumweight (Kg)

2502670 0.5 3 11.9 120 318 0 1000 393

2502680 0.5 4 12.7 127 346 0 1000 421

2502710 0.5 7 14.4 144 438 0 1000 946

2502740 0.5 12 17.0 170 572 1 1000 734

2502760 0.5 19 19.6 197 749 2 1000 895

2502770 0.5 24 21.9 219 873 2 1000 599

2502790 0.5 27 22.2 223 912 2 500 618

2502840 1.0 3 12.7 128 366 0 1000 441

2502850 1.0 4 13.6 136 409 0 1000 496

2502880 1.0 7 15.5 156 521 0 1000 608

2502900 1.0 12 19.4 194 744 2 500 534

2502920 1.0 19 21.6 216 921 2 500 623

2502930 1.0 24 25.3 254 1 280 2 500 884

2502950 1.0 27 25.7 258 1 343 2 500 916

2503000 1.5 3 13.6 137 414 0 1000 501

2503010 1.5 4 15.0 150 482 0 1000 569

2503020 1.5 7 16.8 168 601 1 500 376

2503030 1.5 12 21.1 211 869 2 500 597

2503050 1.5 19 24.3 244 1 256 2 500 790

2503060 1.5 24 27.8 278 1 522 3 500 1005

2503070 1.5 27 28.7 287 1 617 3 500 1053

Electrical Data

Kewberg Cables & Braids (Pty) Ltd.

26

It is used for transmission of analogue and

digital signals in process control systems. It

will be used for indoor and outdoor installa-

tion, in dry and wet locations, on racks, and

in conduits. Not allowed for direct connection

to low impedance source, e.g. the public

mains electricity supply. It is not recom-

mended for direct burial.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.5mm2 39.00 Ω/km 300/500v

1.0mm2 19.50 Ω/km 600/1000v

1.5mm2 13.30 Ω/km 600/1000v

Control Cables

Multi-cores—XLPE Insulated, Overall screened , APL / FR armoured

E&OE

Applications & features

Electrical Data

Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insulated, overall foil

screened with tinned copper drain wire . Colour coded cores up to 4 core , Thereafter white numbered cores

identified by black alpha numerical marking . Cable supplied with a bedding sheath and a UV flame retardant

aluminium polyethylene laminate (APL/FR) for protection . A tin copper drain wire is laid under the APL.

Standard cable is black and coloured cable can be supplied on request .

Construction

Product CodeSize

(mm²)Cores

Nominal OD(mm)

Minimumbending ra-dius (mm)

± Kg / Km Gland SizeStandard

drum length(m)

Grossdrum

weight(Kg)

2501370 0.5 4 11.5 104 136 1 1000 211

2501400 0.5 7 13.2 120 185 1 1000 272

2501430 0.5 12 15.8 143 259 2 1000 346

2501450 0.5 19 18.5 167 366 2 1000 512

2501460 0.5 24 20.8 187 436 3 500 305

2501480 0.5 27 21.1 190 464 3 500 394

2501540 1.0 3 11.6 105 145 1 1000 220

2501550 1.0 4 12.5 113 169 1 1000 244

2501580 1.0 7 14.4 130 239 1 1000 326

2501600 1.0 12 18.3 165 370 2 500 256

2501620 1.0 19 20.5 185 494 3 500 334

2501630 1.0 24 23.5 212 619 3 500 472

2501650 1.0 27 23.9 216 665 3 500 495

2501710 1.5 3 12.5 113 179 1 1000 254

2501720 1.5 4 13.9 125 217 1 1000 304

2501730 1.5 7 15.6 141 284 2 500 217

2501740 1.5 12 20.0 180 449 2 500 312

2501760 1.5 19 22.5 203 611 3 500 468

2501770 1.5 24 26.0 234 769 3 500 531

2501780 1.5 27 26.4 238 829 3 902 561

27

Kewberg Cables & Braids (Pty) Ltd.

27

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Control Cables

Multi– Cores —Unscreened - 300/500v

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed .

2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereaf-

ter black numbered cores with a green/yellow earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREARESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v

1.5mm2 12.10 300/500v

Product Code Size (mm²) Cores Nominal OD (mm) Packing (m) Gland Size

2000580 0.75 2 4.7 1000 00

2000590 0.75 3 5.1 1000 00

2000600 0.75 4 5.7 1000 00

2000610 0.75 5 6.3 1000 00

2000620 0.75 6 7.0 1000 0

2000630 0.75 7 7.1 1000 0

2000640 0.75 8 7.8 1000 0

2000650 0.75 10 9.4 1000 0

2000660 0.75 12 9.8 1000 0

2000670 0.75 14 10.3 500 0

2000680 0.75 16 11.1 500 1

2000690 0.75 18 11.8 500 1

2000700 0.75 19 11.8 500 1

2000710 0.75 20 12.5 500 1

2000720 0.75 21 13.0 500 1

2000730 0.75 24 14.1 500 1

2000740 0.75 25 14.1 500 1

2000750 0.75 27 14.5 500 2

2000760 0.75 30 15.8 500 2

2000770 0.75 32 15.9 500 2

2000780 0.75 34 16.4 500 2

2000790 0.75 36 16.5 500 2

2000800 0.75 37 16.5 500 2

2000810 0.75 40 17.7 500 2

2000820 0.75 42 17.7 500 2

2000830 0.75 50 19.8 500 2

2000840 0.75 61 21.2 500 3

Kewberg Cables & Braids (Pty) Ltd.

28

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Control Cables

Multi– Cores —Unscreened - 300/500v

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed . 2,3 and 4 cores are

colour coded (blue, brown , green/yellow and black ) thereafter blablack numbered cores with a green/

yellow earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v

1.5mm2 12.10 300/500v

Product Code Size (mm²)Cores

Nominal OD(mm)

Packing (m) Gland Size

2000850 1.00 2 5.0 1000 00

2000860 1.00 3 5.4 1000 00

2000870 1.00 4 6.0 1000 00

2000880 1.00 5 6.7 1000 00

2000890 1.00 6 7.5 1000 0

2000900 1.00 7 7.5 1000 0

2000910 1.00 8 8.3 1000 0

2000920 1.00 10 10.0 1000 0

2000930 1.00 12 10.4 1000 0

2000940 1.00 14 11.0 500 1

2000950 1.00 16 11.7 500 1

2000960 1.00 18 12.5 500 1

2000970 1.00 19 12.5 500 1

2000980 1.00 20 13.3 500 1

2000990 1.00 21 13.8 500 1

2001000 1.00 22 13.8 500 1

2001010 1.00 24 15.0 500 2

2001020 1.00 25 15.0 500 2

2001030 1.00 27 15.4 500 2

2001040 1.00 30 16.0 500 2

2001050 1.00 32 16.7 500 2

2001060 1.00 34 17.5 500 2

2001070 1.00 36 17.8 500 2

2001080 1.00 37 17.8 500 2

2001090 1.00 40 18.8 500 2

2001100 1.00 42 18.8 500 2

2001110 1.00 50 21.0 500 3

2001120 1.00 61 22.5 500 3

2001130 1.00 65 23.8 500 3

29

Kewberg Cables & Braids (Pty) Ltd.

29

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Control Cables

Multi– Cores —Unscreened - 300/500v

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed .

2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereaf-

ter black numbered cores with a green/yellow earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREARESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v

1.5mm2 12.10 300/500v

Product Code Size (mm²)Cores

Nominal OD(mm)

Packing (m) Gland Size

2001140 1.50 2 5.9 1000 00

2001150 1.50 3 6.4 1000 00

2001160 1.50 4 7.1 1000 0

2001170 1.50 5 7.9 1000 0

2001180 1.50 6 8.8 1000 0

2001190 1.50 7 8.8 1000 0

2001200 1.50 8 9.8 1000 0

2001210 1.50 10 11.8 1000 1

2001220 1.50 12 12.2 1000 1

2001230 1.50 14 13.0 500 1

2001240 1.50 16 13.8 500 1

2001250 1.50 18 14.7 500 2

2001260 1.50 19 14.7 500 2

2001270 1.50 20 15.7 500 2

2001280 1.50 21 16.3 500 2

2001290 1.50 24 17.7 500 2

2001300 1.50 25 17.7 500 2

2001310 1.50 27 18.1 500 2

2001320 1.50 30 18.9 500 2

2001330 1.50 32 19.7 500 2

2001340 1.50 34 20.6 500 3

2001350 1.50 36 20.8 500 3

2001360 1.50 37 20.8 500 3

2001370 1.50 40 22.2 500 3

2001390 1.50 50 24.8 500 3

2001400 1.50 60 26.5 500 3

Kewberg Cables & Braids (Pty) Ltd.

30

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Control Cables

Multi– Cores —Unscreened - 600/1000v

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed . 2,3 and 4 cores are

colour coded (blue, brown , green/yellow and black ) thereafter black numbered cores with a green/yellow

earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREARESISTANCE RATING

1.0mm2 18.10 600/1000V

1.5mm2 12.10 600/1000V

2.5mm2 7.41 600/1000V4.0mm2 4.61 600/1000V6.0mm2 3.08 600/1000V

10.0mm2 1.83 600/1000V16.0mm2 1.15 600/1000V

Product Code Size (mm²)Cores

Nominal OD(mm)

Packing (m) Gland Size

1.00 2 7.2 1000 00

1.00 3 7.6 1000 00

1.00 4 8.3 1000 0

1.00 6 10.0 1000 0

1.00 7 10.9 1000 0

1.00 8 13.20 1000 1

1.00 12 13.60 1000 2

1.00 16 15.10 500 2

1.00 20 17.90 500 2

1.00 30 20.70 500 2

1.00 50 26.50 500 3

1.50 2 8.0 1000 00

1.50 3 8.5 1000 0

1.50 4 9.3 1000 0

1.50 6 11.6 1000 1

1.50 7 11.6 1000 1

1.50 12 15.3 1000 2

1.50 14 16.1 500 2

1.50 19 18.4 500 2

1.50 20 19.4 500 2

1.50 24 21.6 500 3

1.50 25 21.6 500 3

1.50 27 22.1 500 3

31

Kewberg Cables & Braids (Pty) Ltd.

31

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Control Cables

Multi– Cores —Unscreened - 600/1000v

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed . 2,3 and 4 cores are

colour coded (blue, brown , green/yellow and black ) thereafter black numbered cores with a green/yellow

earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREARESISTANCE RATING

1.0mm2 18.10 600/1000V

1.5mm2 12.10 600/1000V

2.5mm2 7.41 600/1000V4.0mm2 4.61 600/1000V6.0mm2 3.08 600/1000V

10.0mm2 1.83 600/1000V16.0mm2 1.15 600/1000V

Product Code Size (mm²)Cores

Nominal OD (mm) Packing (m) Gland Size

2001410 2.50 2 8.8 1000 0

2001420 2.50 3 9.3 1000 0

2001430 2.50 4 10.6 1000 0

2001440 2.50 5 11.7 1000 1

2001450 2.50 6 12.8 1000 1

2001460 2.50 7 12.8 1000 1

2001470 2.50 8 13.9 1000 1

2001490 2.50 10 16.4 1000 2

2001500 2.50 12 16.9 1000 2

2001510 2.50 14 18.3 500 2

2001520 2.50 16 19.3 500 2

2001530 2.50 18 20.4 500 2

2001540 2.50 19 20.4 500 2

2001550 2.50 20 21.5 500 3

2001560 2.50 21 22.3 500 3

2001570 2.50 24 24.4 500 3

2001580 2.50 25 24.4 500 3

2001590 2.50 27 24.9 500 3

2001600 2.50 30 25.8 500 3

2001610 2.50 32 26.9 500 4

2001620 2.50 34 28.2 500 4

2001630 2.50 36 28.2 500 4

2001640 2.50 37 28.2 500 4

2001650 2.50 50 33.2 500 4

Kewberg Cables & Braids (Pty) Ltd.

32

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Control Cables

Multi– Cores —Unscreened - 600/1000v

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed . 2,3 and 4 cores are

colour coded (blue, brown , green/yellow and black ) thereafter black numbered cores with a green/yellow

earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREARESISTANCE RATING

1.0mm2 18.10 600/1000V

1.5mm2 12.10 600/1000V

2.5mm2 7.41 600/1000V4.0mm2 4.61 600/1000V6.0mm2 3.08 600/1000V

10.0mm2 1.83 600/1000V16.0mm2 1.15 600/1000V

Product Code Size (mm²)

Cores

Nominal OD (mm) Packing (m) Gland Size

2001660 4.00 2 10.8 500 0

2001670 4.00 3 11.5 500 1

2001680 4.00 4 13.1 500 1

2001690 4.00 5 14.4 500 1

2001700 4.00 6 15.8 500 2

2001710 4.00 7 15.8 500 2

2001720 4.00 12 21.5 500 3

2001730 4.00 19 25.8 500 3

2001740 6.00 2 12.2 500 1

2001750 6.00 3 13.0 500 1

2001760 6.00 4 14.7 500 2

2001770 6.00 5 16.1 500 2

2001780 6.00 6 17.7 500 2

2001790 6.00 7 17.7 500 2

2001800 10.00 2 14.8 500 2

2001810 10.00 3 15.8 500 2

2001820 10.00 4 17.3 500 2

2001830 10.00 5 19.1 500 2

2001840 10.00 6 21.0 500 3

2001800 10.00 7 21.0 500 3

2001860 16.00 3 18.3 500 2

2001870 16.00 4 20.1 500 2

33

Kewberg Cables & Braids (Pty) Ltd.

33

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

These cables are used in machinery, machine

tools, system and appliance engineering,

measuring, control, heating and air conditioning

technologies.

Control Cables

Multi– Cores — Copper Braid screened

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , copper wire braid screened , PVC

sheathed . 2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereafter black

numbered cores with a green/yellow earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v

1.5mm2 12.10 300/500v

2.5mm2 7.41 600/1000V

4.0mm2 4.61 600/1000V

Product CodeSize

(mm²) CoresNominal OD

(mm)Packing (m) Gland Size

2002870 0.75 2 7.1 1000 0

2002880 0.75 3 7.5 1000 0

2002890 0.75 4 8.1 1000 0

2002900 0.75 5 8.8 1000 0

2002910 0.75 6 9.8 1000 0

2002920 0.75 7 9.8 1000 0

2002930 0.75 8 10.6 1000 0

2002940 0.75 10 12.2 1000 1

2002950 0.75 12 12.5 1000 1

2002960 0.75 14 13.2 500 1

2002970 0.75 16 13.8 500 1

2002980 0.75 18 14.9 500 2

2002990 0.75 19 14.9 500 2

2003000 0.75 20 15.7 500 2

2003010 0.75 21 16.2 500 2

2003020 0.75 24 17.3 500 2

2003030 0.75 25 17.3 500 2

2003040 0.75 27 17.6 500 2

2003050 0.75 30 18.2 500 2

2003060 0.75 32 18.9 500 2

2003070 0.75 34 19.6 500 2

2003080 0.75 36 19.6 500 2

2003090 0.75 37 19.8 500 2

2003100 0.75 40 20.9 500 3

2003110 0.75 42 20.9 500 3

2003120 0.75 50 23.4 500 3

Kewberg Cables & Braids (Pty) Ltd.

34

Control Cables

Multi– Cores — Copper Braid screened

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , copper wire braid screened , PVC

sheathed . 2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereafter black

numbered cores with a green/yellow earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v

1.5mm2 12.10 300/500v

2.5mm2 7.41 600/1000V

4.0mm2 4.61 600/1000V

Product CodeSize

(mm²) CoresNominal OD

(mm)Packing (m) Gland Size

2003130 1.00 2 7.4 1000 0

2003140 1.00 3 7.8 1000 0

2003150 1.00 4 8.4 1000 0

2003160 1.00 5 9.2 1000 0

2003170 1.00 6 10.3 1000 0

2003180 1.00 7 10.3 1000 0

2003190 1.00 8 11.1 1000 1

2003200 1.00 10 12.8 1000 1

2003210 1.00 12 13.2 1000 1

2003220 1.00 14 13.8 500 1

2003230 1.00 16 14.6 500 2

2003240 1.00 18 15.7 500 2

2003250 1.00 19 15.7 500 2

2003260 1.00 20 16.5 500 2

2003270 1.00 21 17.1 500 2

2003280 1.00 24 18.2 500 2

2003290 1.00 25 18.2 500 2

2003300 1.00 27 18.6 500 2

2003310 1.00 30 19.2 500 2

2003320 1.00 32 20.0 500 2

2003330 1.00 34 20.7 500 3

2003340 1.00 36 20.7 500 3

2003350 1.00 37 20.7 500 3

2003360 1.00 40 22.1 500 3

2003370 1.00 42 22.1 500 3

2003380 1.00 50 24.6 500 3

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

These cables are used in machinery, machine

tools, system and appliance engineering,

measuring, control, heating and air conditioning

technologies.

35

Kewberg Cables & Braids (Pty) Ltd.

35

Control Cables

Multi– Cores — Copper Braid screened

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , copper wire braid screened , PVC

sheathed . 2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereafter black

numbered cores with a green/yellow earth conductor .

Construction

Product CodeSize

(mm²) CoresNominal OD

(mm)Packing (m) Gland Size

2003400 1.50 2 8.8 1000 0

2003410 1.50 3 9.3 1000 0

2003420 1.50 4 10.5 1000 0

2003430 1.50 5 11.4 1000 1

2003440 1.50 6 12.4 1000 1

2003450 1.50 7 12.4 1000 1

2003460 1.50 8 15.6 1000 2

2003470 1.50 10 15.6 1000 2

2003480 1.50 12 16.1 1000 2

2003490 1.50 14 16.9 500 2

2003500 1.50 16 18.2 500 2

2003510 1.50 18 19.2 500 2

2003520 1.50 19 19.2 500 2

2003530 1.50 20 20.3 500 2

2003540 1.50 21 20.9 500 3

2003550 1.50 24 22.4 500 3

2003560 1.50 25 22.4 500 3

2003570 1.50 27 22.9 500 3

2003580 1.50 30 23.7 500 3

2003590 1.50 32 24.6 500 3

2003600 1.50 34 25.6 500 3

2003610 1.50 36 25.6 500 3

2003620 1.50 37 25.6 500 3

2003630 1.50 40 27.3 500 4

2003640 1.50 42 27.3 500 4

2003650 1.50 50 30.5 500 4

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v

1.5mm2 12.10 300/500v

2.5mm2 7.41 600/1000V

4.0mm2 4.61 600/1000V

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

These cables are used in machinery, machine

tools, system and appliance engineering,

measuring, control, heating and air conditioning

technologies.

Kewberg Cables & Braids (Pty) Ltd.

36

Control Cables

Multi– Cores — Copper Braid screened

E&OE

Applications & features

Plain flexible stranded annealed copper conductor, PVC insulated , copper wire braid screened , PVC

sheathed . 2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereafter black

numbered cores with a green/yellow earth conductor .

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v

1.5mm2 12.10 300/500v

2.5mm2 7.41 600/1000V

4.0mm2 4.61 600/1000V

Product CodeSize

(mm²) Cores

Nominal OD(mm)

Packing (m) Gland Size

2003660 2.50 2 10.00 1000 0

2003670 2.50 3 10.60 1000 0

2003680 2.50 4 11.50 1000 1

2003690 2.50 5 12.90 1000 1

2003700 2.50 6 14.00 1000 1

2003710 2.50 7 14.00 1000 1

2003720 2.50 8 15.20 1000 2

2003730 2.50 10 17.60 1000 2

2003740 2.50 12 18.20 1000 2

2003750 2.50 14 19.10 500 2

2003760 2.50 16 20.10 500 2

2003770 2.50 18 21.20 500 3

2003780 2.50 19 21.20 500 3

2003790 2.50 20 22.40 500 3

2003800 2.50 21 23.50 500 3

2003810 2.50 24 25.20 500 3

2003820 2.50 25 25.20 500 3

2003830 2.50 27 25.80 500 3

2003840 2.50 30 26.70 500 4

2003850 2.50 32 27.70 500 4

2003860 2.50 34 28.80 500 4

2003870 2.50 36 28.80 500 4

2003880 2.50 37 28.80 500 4

2003890 2.50 40 30.70 500 4

2003900 2.50 42 30.70 500 4

2003910 2.50 50 34.30 500 4

2003920 4.00 2 12.40 500 1

2003930 4.00 3 13.10 500 12003940 4.00 4 13.90 500 1

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

These cables are used in machinery, machine

tools, system and appliance engineering,

measuring, control, heating and air conditioning

technologies.

37

Kewberg Cables & Braids (Pty) Ltd.

37

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Control Cables

Multi– Cores — Galvanised Steel Wire Braid screened

E&OE

Applications & features

Construction

CONDUCTOR CONDUCTOR VOLTAGEAREA RESISTANCE RATING

0.5mm2 39 300/500v0.75mm2 24.50 300/500v1.0mm2 18.10 300/500v1.5mm2 12.10 300/500v2.5mm2 7.41 600/1000v4.0mm2 4.61 600/1000v6.0mm2 3.08 600/1000v

10.0mm2 1.83 600/1000v16.0mm2 1.15 600/1000v

Product Code Size (mm²) CoresNominal OD

(mm)Packing (m) Gland Size

2900010 0.50 2 8.10 1000 0

2900060 0.50 3 8.60 1000 0

2900070 0.50 4 9.60 1000 0

2900080 0.50 5 10.00 1000 0

2900090 0.50 7 11.10 1000 0

2900030 0.50 12 11.20 1000 1

2900040 0.50 14 13.80 500 1

2900050 0.50 20 15.70 500 2

2900120 0.75 2 9.10 1000 0

2900150 0.75 3 9.50 1000 0

2900170 0.75 4 10.10 1000 0

2900190 0.75 5 10.80 1000 0

2900220 0.75 7 11.80 1000 1

2900100 0.75 12 14.50 1000 1

2900110 0.75 20 18.10 500 2

2900140 0.75 34 22.00 500 3

2900210 0.75 61 29.00 500 4

2900310 1.00 2 9.40 1000 0

2900360 1.00 3 9.80 1000 0

2900400 1.00 4 10.40 1000 0

2900430 1.00 5 11.20 1000 1

2900450 1.00 7 12.30 1000 1

2900230 1.00 10 14.80 1000 2

2900250 1.00 12 15.20 1000 2

2900260 1.00 14 16.20 500 2

2900270 1.00 19 18.10 500 2

2900280 1.00 20 18.90 500 2

2900290 1.00 25 20.60 500 2

2900380 1.00 40 24.50 500 22900420 1.00 50 27.00 500 3

Plain flexible stranded annealed copper conductor, PVC insulated , PVC bedded, Galvanised steel wire

Braid, PVC sheathed. 2,3 and 4 cores are colour coded (blue, brown, green/yellow and black ) thereafter

black numbered cores with a green/yellow earth conductor . Various sheathing grades and colours avail-

able

Plain flexible stranded annealed copper conductor, PVC insulated , PVC bedded, Galvanised steel wire

Braid, PVC sheathed. 2,3 and 4 cores are colour coded (blue, brown, green/yellow and black ) thereafter

black numbered cores with a green/yellow earth conductor . Various sheathing grades and colours avail-

able

Kewberg Cables & Braids (Pty) Ltd.

38

It is used for transmission of analogue and digi-

tal signals in process control systems. It will be

used for indoor and outdoor installation, in dry

and wet locations, on racks, and in conduits.

Not allowed for direct connection to low imped-

ance source, e.g. the public mains electricity

supply. It is not recommended for direct burial.

Control Cables

Multi– Cores — Galvanised Steel Wire Braid screened

E&OE

Applications & features

Construction

CONDUCTOR CONDUCTOR VOLTAGEAREA RESISTANCE RATING

0.5mm2 39 300/500v0.75mm2 24.50 300/500v1.0mm2 18.10 300/500v1.5mm2 12.10 300/500v2.5mm2 7.41 600/1000v4.0mm2 4.61 600/1000v6.0mm2 3.08 600/1000v10.0mm2 1.83 600/1000v16.0mm2 1.15 600/1000v

Product Code Size (mm²) CoresNominal OD

(mm)Packing (m) Gland Size

2900530 1.50 2 10.80 1000 02900560 1.50 3 11.30 1000 12900600 1.50 4 12.50 1000 12900630 1.50 5 13.40 1000 12900660 1.50 7 14.40 1000 12900480 1.50 12 18.10 1000 22900500 1.50 14 19.30 500 22900510 1.50 19 21.60 500 3

2900750 2.50 2 12.40 1000 12900760 2.50 3 13.00 1000 12900770 2.50 4 13.90 1000 12900780 2.50 5 15.30 1000 22900800 2.50 7 16.40 500 22900730 2.50 12 21.00 500 32900740 2.50 19 24.00 500 3

2900820 4.00 2 15.20 500 22900830 4.00 3 15.90 500 22900850 4.00 4 16.70 500 22900860 4.00 7 19.50 2

2900870 6.00 4 18.60 500 22900890 6.00 7 21.50 500 3

2900690 10.00 4 21.40 500 3

2900710 16.00 4 24.20 500 3

39

Kewberg Cables & Braids (Pty) Ltd.

39

These multicore flexible cables are designed

for high density wiring between components

and within instruments and electronic equip-

ment. They are extensively used in aircraft,

process control systems, computers, data

processors, military vehicles and military

equipment

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Defence Specification

Cables

Paired Cables—Overall Screened - Defence Standard 61/12

E&OE

Applications & features

Tinned stranded annealed copper conductor, PVC insulated (150/250v), aluminium / Mylar foil screened,

tinned stranded copper drain wire, PVC sheathed (grey)

Construction

CONDUCTOR CONDUCTOR VOLTAGE

RESISTANCE RATING

0.22mm2 92.4 Ω/km 150/250v

0.50mm2 40.1 Ω/km 150/250v

Product CodeSize

(mm²)Pairs

Nominal OD(mm)

± Kg / Km Packing (m) Core Identification Gland Size

2003950 0.22 1 3.6 27 1000 DEF STAN 61-12 00

2003960 0.22 2 6.2 51 1000 DEF STAN 61-12 00

2003970 0.22 3 6.5 62 1000 DEF STAN 61-12 00

2003980 0.22 4 7.2 76 1000 DEF STAN 61-12 00

2004000 0.22 6 8.1 108 1000 DEF STAN 61-12 00

2004020 0.22 8 9.2 122 1000 DEF STAN 61-12 0

2004050 0.22 12 11.6 179 1000 DEF STAN 61-12 1

2004110 0.22 18 13.4 242 500 DEF STAN 61-12 1

2004140 0.22 25 15.4 323 500 DEF STAN 61-12 2

2004150 0.22 30 16.4 355 500 DEF STAN 61-12 2

2004160 0.22 36 18.3 408 500 DEF STAN 61-12 2

2004165 0.22 50 20.3 518 500 DEF STAN 61-12 2

2004170 0.50 1 5.1 56 1000 DEF STAN 61-12 00

2004180 0.50 2 7.6 76 1000 DEF STAN 61-12 00

2004190 0.50 3 8.1 105 1000 DEF STAN 61-12 00

2004200 0.50 4 8.6 119 1000 DEF STAN 61-12 0

2004220 0.50 6 11.2 160 1000 DEF STAN 61-12 0

2004240 0.50 8 12.2 205 1000 DEF STAN 61-12 1

2004270 0.50 12 15.2 271 1000 DEF STAN 61-12 2

2004330 0.50 18 18.8 381 500 DEF STAN 61-12 2

2004340 0.50 20 21.3 418 500 DEF STAN 61-12 32004360 0.50 25 22.3 497 500 DEF STAN 61-12 3

Electrical Data

Kewberg Cables & Braids (Pty) Ltd.

40

These multicore flexible cables are designed

for high density wiring between components

and within instruments and electronic equip-

ment. They are extensively used in aircraft,

process control systems, computers, data

processors, military vehicles and military

equipment

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Paired Cables—Individual and Overall Screened - Defence Standard 61/12

E&OE

Applications & features

Electrical Data

Construction

Tinned stranded annealed copper conductor, PVC insulated (150/250v), aluminium / Mylar foil screened,

tinned stranded copper drain wire, PVC sheathed (grey)

Defence Specification

Cables

CONDUCTOR CONDUCTOR VOLTAGE

RESISTANCE RATING

0.22mm2 92.4 Ω/km 150/250v

0.50mm2 40.1 Ω/km 150/250v

ProductCode

Size(mm²)

PairsNominal OD

(mm)± Kg / Km

Packing(m)

Core Identification Gland Size

2004395 0.22 2 6.3 63 1000 DEF STAN 61-12 00

2004400 0.22 3 7.1 77 1000 DEF STAN 61-12 00

2004410 0.22 4 7.5 95 1000 DEF STAN 61-12 0

2004430 0.22 6 8.8 135 1000 DEF STAN 61-12 0

2004450 0.22 8 9.7 153 1000 DEF STAN 61-12 0

2004470 0.22 12 11.6 223 1000 DEF STAN 61-12 1

0

2004560 0.50 2 8.8 95 1000 DEF STAN 61-12 0

2004570 0.50 3 10.0 131 1000 DEF STAN 61-12 0

2004580 0.50 4 10.8 148 1000 DEF STAN 61-12 0

2004600 0.50 6 13.2 200 1000 DEF STAN 61-12 0

2004610 0.50 8 14.7 256 1000 DEF STAN 61-12 2

2004630 0.50 12 17.8 339 1000 DEF STAN 61-12 2

41

Kewberg Cables & Braids (Pty) Ltd.

41

These multicore flexible cables are designed

for high density wiring between components

and within instruments and electronic equip-

ment. They are extensively used in aircraft,

process control systems, computers, data

processors, military vehicles and military

equipment

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Defence Specification

Cables

Multi Cores—Tinned copper Braid Overall Screened - Defence Standard 61/12

E&OE

Applications & features

Tinned stranded annealed copper conductor, PVC insulated (150/250v), clear polyester taped, tinned copper

wire braid screened, PVC sheathed (grey)

Construction

CONDUCTOR CONDUCTOR VOLTAGE

RESISTANCE RATING

0.22mm2 92.4 Ω/km 150/250v

0.50mm2 40.1 Ω/km 150/250v

Electrical Data

ProductCode

Size(mm²) Cores

Nominal OD(mm)

± Kg / KmPacking

(m)Core Identification Gland Size

2002330 0.22 2 4.1 30 1000 DEF STAN 61-12 00

2002340 0.22 3 4.6 36 1000 DEF STAN 61-12 00

2002350 0.22 4 4.9 40 1000 DEF STAN 61-12 00

2002380 0.22 7 6.1 63 1000 DEF STAN 61-12 00

2002390 0.22 8 6.4 81 1000 DEF STAN 61-12 00

2002400 0.22 10 7.1 86 1000 DEF STAN 61-12 00

2002410 0.22 12 7.3 88 1000 DEF STAN 61-12 00

2002440 0.22 18 8.6 138 1000 DEF STAN 61-12 0

2002460 0.22 20 9.1 146 1000 DEF STAN 61-12 0

2002490 0.22 25 9.6 166 1000 DEF STAN 61-12 0

2002600 0.50 2 6.1 53 1000 DEF STAN 61-12 00

2002610 0.50 3 6.6 64 1000 DEF STAN 61-12 00

2002620 0.50 4 7.6 78 1000 DEF STAN 61-12 00

2002640 0.50 6 8.6 91 1000 DEF STAN 61-12 0

2002650 0.50 7 9.1 108 1000 DEF STAN 61-12 0

2002660 0.50 8 10.2 130 1000 DEF STAN 61-12 0

2002680 0.50 12 11.2 171 1000 DEF STAN 61-12 0

2002700 0.50 16 12.2 200 1000 DEF STAN 61-12 0

2002710 0.50 18 12.7 230 1000 DEF STAN 61-12 0

2002730 0.50 20 13.7 266 1000 DEF STAN 61-12 0

2002760 0.50 25 15.2 339 1000 DEF STAN 61-12 2

2002780 0.50 30 16.2 383 1000 DEF STAN 61-12 2

2002790 0.50 36 18.3 447 500 DEF STAN 61-12 2

Kewberg Cables & Braids (Pty) Ltd.

42

These flexible cables are designed for high

density wiring between components and

within instruments and electronic equipment.

They are extensively used in aircraft, process

control systems, computers, data proces-

sors, military vehicles and military equipment

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Multi Pairs—Tinned copper Braid Overall Screened - Defence Standard 61/12

E&OE

Applications & features

Electrical Data

Construction

Tinned stranded annealed copper conductor, PVC insulated (150/250v), clear polyester taped, tinned copper

wire braid screened, PVC sheathed (grey)

Defence Specification

Cables

CONDUCTOR CONDUCTOR VOLTAGE

RESISTANCE RATING

0.22mm2 92.4 Ω/km 150/250v

0.50mm2 40.1 Ω/km 150/250v

ProductReference

Size(mm²) Pairs

Nominal OD(mm)

± Kg / KmPacking

(m)Core Identification Gland Size

2002325 0.22 1 4.1 30 1000 DEF STAN 61-12 00

2002335 0.22 2 6.2 42 1000 DEF STAN 61-12 00

2002345 0.22 3 6.5 64 1000 DEF STAN 61-12 00

2002355 0.22 4 7.1 85 1000 DEF STAN 61-12 00

2002375 0.22 6 8.1 101 1000 DEF STAN 61-12 00

2002395 0.22 8 9.3 126 1000 DEF STAN 61-12 0

43

Kewberg Cables & Braids (Pty) Ltd.

43

These flexible cables are designed for high

density wiring between components and

within instruments and electronic equipment.

They are extensively used in aircraft, process

control systems, computers, data proces-

sors, military vehicles and military equipment

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Defence Specification

Cables

Multi Cores—Tinned Overall Foil Screened - Defence Standard 61/12

E&OE

Applications & features

Tinned stranded annealed copper conductor, PVC insulated (150/250V), overall foil

screened with tin copper drain wire, PVC sheathed (grey).Construction

CONDUCTOR CONDUCTOR VOLTAGE

RESISTANCE RATING

0.22mm2 92.4 Ω/km 150/250v

0.50mm2 40.1 Ω/km 150/250v

Electrical Data

Product Refer-ence

Size(mm²)

Cores

NominalOD (mm)

± Kg / Km Packing (m) Core Identification Gland Size

2001890 0.22 2 3.5 23 1000 DEF STAN 61-12 00

2001900 0.22 3 4.0 27 1000 DEF STAN 61-12 00

2001910 0.22 4 4.3 30 1000 DEF STAN 61-12 00

2001940 0.22 7 5.5 47 1000 DEF STAN 61-12 00

2001950 0.22 8 5.8 61 1000 DEF STAN 61-12 00

2001960 0.22 10 6.5 65 1000 DEF STAN 61-12 00

2001970 0.22 12 6.5 66 1000 DEF STAN 61-12 00

2002000 0.22 18 7.8 104 1000 DEF STAN 61-12 0

2002020 0.22 20 8.3 110 1000 DEF STAN 61-12 0

2002050 0.22 25 8.8 125 1000 DEF STAN 61-12 0

2002100 0.50 2 5.3 40 1000 DEF STAN 61-12 00

2002110 0.50 3 5.8 48 1000 DEF STAN 61-12 00

2002120 0.50 4 6.8 59 1000 DEF STAN 61-12 00

2002140 0.50 6 7.8 69 1000 DEF STAN 61-12 0

2002150 0.50 7 8.3 81 1000 DEF STAN 61-12 0

2002160 0.50 8 9.4 97 1000 DEF STAN 61-12 0

2002180 0.50 12 10.4 128 1000 DEF STAN 61-12 0

2002200 0.50 16 11.4 150 1000 DEF STAN 61-12 0

2002210 0.50 18 11.9 173 1000 DEF STAN 61-12 0

2002230 0.50 20 12.9 199 1000 DEF STAN 61-12 0

2002260 0.50 25 14.4 254 1000 DEF STAN 61-12 2

2002280 0.50 30 15.4 287 1000 DEF STAN 61-12 2

2002310 0.50 36 17.5 335 500 DEF STAN 61-12 2

Kewberg Cables & Braids (Pty) Ltd.

44

These flexible cables are designed for high

density wiring between components and

within instruments and electronic equipment.

They are extensively used in aircraft, process

control systems, computers, data proces-

sors, military vehicles and military equipment

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Multi Cores—Unscreened Defence Standard 61/12

E&OE

Applications & features

Electrical Data

Construction

Tinned stranded annealed copper conductor, PVC insulated (150/250V), clear polyester tape wrapped. PVC

outer sheath (grey).

Defence Specification

Cables

CONDUCTOR CONDUCTOR VOLTAGE

RESISTANCE RATING

0.22mm2 92.4 Ω/km 150/250v

0.50mm2 40.1 Ω/km 150/250v

Product Refer-ence

Size(mm²)

Cores

Nominal OD(mm)

± Kg / KmPacking

(m)Core Identifica-

tionGlandSize

2000040 0.22 2 3.5 20 1000 DEF STAN 61-12 00

2000060 0.22 3 4.0 24 1000 DEF STAN 61-12 00

2000065 0.22 4 4.3 27 1000 DEF STAN 61-12 00

2000090 0.22 7 5.5 44 1000 DEF STAN 61-12 00

2000100 0.22 8 5.8 58 1000 DEF STAN 61-12 00

2000110 0.22 10 6.5 62 1000 DEF STAN 61-12 00

2000120 0.22 12 6.5 63 1000 DEF STAN 61-12 00

2000150 0.22 18 7.8 101 1000 DEF STAN 61-12 0

2000170 0.22 20 8.3 107 1000 DEF STAN 61-12 0

2000200 0.22 25 8.8 122 1000 DEF STAN 61-12 0

2000310 0.50 2 5.3 37 1000 DEF STAN 61-12 00

2000320 0.50 3 5.8 45 1000 DEF STAN 61-12 00

2000330 0.50 4 6.8 56 1000 DEF STAN 61-12 00

2000350 0.50 6 7.8 66 1000 DEF STAN 61-12 0

2000360 0.50 7 8.3 78 1000 DEF STAN 61-12 0

2000370 0.50 8 9.4 94 1000 DEF STAN 61-12 0

2000390 0.50 12 10.4 125 1000 DEF STAN 61-12 0

2000410 0.50 16 11.4 147 1000 DEF STAN 61-12 0

2000420 0.50 18 11.9 170 1000 DEF STAN 61-12 0

2000440 0.50 20 12.9 196 1000 DEF STAN 61-12 0

2000470 0.50 25 14.4 251 1000 DEF STAN 61-12 2

2000490 0.50 30 15.4 284 1000 DEF STAN 61-12 2

2000520 0.50 36 17.5 332 500 DEF STAN 61-12 2

45

Kewberg Cables & Braids (Pty) Ltd.

45

These cables may be used for main power

distribution in general industries, houses and

commercial buildings. These cables are suit-

able for direct burial installations as well as in

air or ducts. The PVC in LHC and HFFR ar-

moured cable is specially formulated to re-

duce corrosive halogen gasses which are

produced by burning PVC, so are suitable for

use in closed areas such as mines and of-

fices.

Remark: - Cables of sizes not listed above is available on request

Power Cables

Power Cables—Multi-cores Steel Wire Armoured FR PVC 600/1000V

E&OE

Applications & features

Electrical Data

Stranded soft high conductivity copper conductors, PVC insulated, PVC bedding sheath , galvanised single

wire armoured, PVC outer sheath, 600/1000v in accordance with SANS 1507-3 . Cable can be supplied

with flame retardant, low halogen on halogen free outer sheath.

Construction

Product CodeSize

(mm²)Cores

DrumLength

Cable Diameter Gland SizeCable Weight

(kg/km)

4200010 1.5 2 500 13.8 0 360

4200020 1.5 3 500 14.3 0 452

4200030 1.5 4 500 15.1 0 506

4200040 1.5 7 500 17.0 1 629

4200050 1.5 12 500 21.2 2 901

4200060 1.5 14 500 22.0 2 980

4200070 1.5 19 500 25.9 2 1404

4200080 1.5 24 500 29.3 3 1687

4200090 1.5 27 500 29.8 3 1783

4200100 1.5 37 500 32.8 3 2153

Product CodeSize

(mm²)Cores

DrumLength

Cable Diameter Gland SizeCable Weight

(kg/km)

4200110 2.5 2 500 14.7 0 480

4200120 2.5 3 500 15.2 1 523

4200130 2.5 4 500 16.2 1 602

4200130 2.5 7 500 18.5 1 756

4200150 2.5 12 500 24.8 2 1306

4200160 2.5 14 500 25.7 2 1421

4200170 2.5 19 500 28.1 3 1695

4200180 2.5 24 500 32.0 3 2053

4200181 2.5 27 500 32.6 3 2181

4200182 2.5 37 300 37.6 4 3011

Kewberg Cables & Braids (Pty) Ltd.

46

These cables may be used for main power

distribution in general industries, houses and

commercial buildings. These cables are suit-

able for direct burial installations as well as in

air or ducts. The PVC in LHC and HFFR ar-

moured cable is specially formulated to re-

duce corrosive halogen gasses which are

produced by burning PVC, so are suitable for

use in closed areas such as mines and of-

fices.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Power Cables

Power Cables—Multi-cores Steel Wire Armoured FR PVC 600/1000V

E&OE

Applications & features

Stranded soft high conductivity copper conductors, PVC insulated, PVC bedding sheath , galvanised single

wire armoured, PVC outer sheath, 600/1000v in accordance with SANS 1507-3 . Cable can be supplied

with flame retardant, low halogen on halogen free outer sheath.

Construction

Product CodeSize

(mm²)Cores

DrumLength

Cable Diameter Gland SizeCable Weight

(kg/km)

4200190 4.0 2 500 16.3 1 590

4200200 4.0 3 500 17.0 1 668

4200210 4.0 4 500 18.4 1 763

4200220 4.0 7 500 21.0 2 986

4200221 4.0 12 500 28.2 3 1426

4200222 4.0 14 500 29.6 3 1885

4200223 4.0 19 500 32.5 3 2282

4200224 4.0 24 500 38.6 4 3113

4200225 4.0 27 500 39.8 4 3354

47

Kewberg Cables & Braids (Pty) Ltd.

47

It is used in panel and switch gear connec-

tions.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Power Cables

Single Core Flex Panel Wire

E&OE

Applications & features

Stranded or solid, plain or tinned copper conductor, flexible grade PVC insulated, 300/500v and 600/1000v

in accordance with sans 1574, suitable for use at -10 °c to 105 °c - in a range of colours

Construction

STRANDED PANEL WIRE

Product Refer-ence

Size(mm²)

NominalStranding

(No. x strandDiameter)

(mm)

ApproximateOverall Di-

ameter(mm)

Current ratingConductorresistance

VoltageRating

Approx.Cable

weight per100m Coil

(kg)

3800010 0.22 7/0.2 1.2 0.5 92 100 0.4

3800011 0.22 7/0.2 1.6 1 92 300/500v 0.5

3800400 0.50 16/0.2 1.9 2 39 300/500v 0.7

3800405 0.50 16/0.2 2.5 3 39 600/1000v 1.1

3800680 0.75 24/0.2 2.35 5 26 300/500v 1.1

3800685 0.75 24/0.2 2.8 6 26 600/1000v 1.3

3800810 1.00 32/0.2 2.55 8 19.5 300/500v 1.5

3800811 1.00 32/0.2 3.1 10 19.5 600/1000v 1.6

3800090 1.50 30/0.25 2.95 13 13.3 300/500v 2.0

3800095 1.50 30/0.25 3.4 16 13.3 600/1000v 2.2

3800500 2.50 50/0.25 3.8 25 7.98 600/1000v 3.1

3800510 4.00 56/0.30 4.6 32 4.96 600/1000v 4.9

SOLID PANEL WIRE

Product Refer-ence

Size(mm²)

StrandDiameter

(mm)

ApproximateOverall Diame-

ter (mm)

Voltage Rat-ing

Conductorresistance

3800269 0.20 0.50 1.25 100v 89.6

3815050 0.30 0.63 1.63 300/500v 56.4

3801047 0.40 0.71 1.71 300/500v 44.4

3800850 0.50 0.80 1.90 300/500v 35.0

3801050 0.63 0.90 2.00 300/500v 27.6

3801060 0.80 1.00 2.10 300/500v 22.4

Kewberg Cables & Braids (Pty) Ltd.

48

For wiring of lamps, audio systems and se-

curity alarms

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Power Cables

Ripcords

E&OE

Applications & features

Flexible plain copper conductors, PVC insulated

Construction

Product Ref.Size

(mm²)No. ofCores

Approx. CableDiam. (mm)

Conductor resistance @ 20 °C max. (Ω/km)

Approx. Cableweight per 100m

Coil (kg)

0.20 2 92

0.40 2 52

0.50 2 39

0.75 2 26

49

Kewberg Cables & Braids (Pty) Ltd.

49

Used for wiring of extension Cords , Kitchen

Appliances , Power Tools and other general

extension to appliances

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Power Cables

Cabtyre

E&OE

Applications & features

Stranded plain copper conductors, PVC insulated, PVC outer sheath.

Construction

Product Ref.Size

(mm²)No. ofCores

Approx. CableDiam. (mm)

Conductor resistance @ 20 °Cmax. (Ω/km)

Approx. Cableweight per 100m

Coil (kg)

1700010 0.5 2 5.2 39 3.91700040 0.5 3 5.5 39 4.71700070 0.5 4 6.0 39 5.5

1700100 0.75 2 6.2 26 5.21700130 0.75 3 7.0 26 6.7170060 0.75 4 7.2 26 7.8

1700210 1.0 2 6.6 19.5 6.31700240 1.0 3 7.0 19.5 7.61700270 1.0 4 8.0 19.5 9.8

1700300 1.5 2 7.8 13.3 8.41700330 1.5 3 8.3 13.3 10.81700360 1.5 4 9.3 13.3 13.5

1700390 2.5 2 9.6 7.98 13.51700420 2.5 3 10.3 7.98 16.81700450 2.5 4 11.9 7.98 21.8

Voltage Rating Light Duty (LD) 150/250 V

Normal Duty(ND)300/500V

Temperature Range -10°C to 70°C

Sheath colours Black, white, grey

Core colours 2 core - brown and blue

3 core - blue, brown and green/yellow

4 core - black, blue, brown and green/yellow

Kewberg Cables & Braids (Pty) Ltd.

50

It ’s a power cable widely used in power sta-

tion installations.

Remark: - Cables of sizes not listed above is available on request

Power Cables

Unarmoured Power Cables—Eskom Spec

E&OE

Applications & features

Stranded plain annealed copper conductor , PVC insulated and PVC sheathed

sheathing material can be flame retardant PVC, low halogen PVC or halogen free

PVC conductors are colour coded up to 4 core and thereafter black with white numbers. Manufactured to

SANS 1507 as far as applicable.

Construction

Product Ref.Size

(mm²)No ofCores

Eskom code

Maximum Conduc-tor Resistance

(Untinned copper)@ 20 °C max. (Ω/km)

Approx. Cable Diam.(mm)

Gland Size

1600010 1.5 2 BVV02CCV 12.10 8.0 001600020 1.5 3 BVV03CCV 12.10 8.5 01600030 1.5 4 BVV04CCV 12.10 9.3 0

1600040 1.5 7 BVV07CCV 12.10 11.6 1

1600060 1.5 12 BVV12CCV 12.10 15.3 21600080 1.5 14 BVV14CCV 12.10 16.1 21600090 1.5 19 BVV19CCV 12.10 18.4 21600120 1.5 27 BVV27CCV 12.10 22.1 31600130 2.50 2 BVV02DCV 7.41 8.8 01600140 2.50 3 BVV03DCV 7.41 9.3 01600150 2.50 4 BVV04DCV 7.41 10.6 01600170 2.50 7 BVV07DCV 7.41 12.8 11600180 2.50 12 BVV12DCV 7.41 16.9 21600200 2.50 19 BVV19CCV 7.41 20.4 21600220 2.50 27 BVV27DCV 7.41 24.9 31600230 2.50 37 BVV37DCV 7.41 28.2 41600240 4.00 2 BVV02ECV 4.61 10.8 01600250 4.00 3 BVV03ECV 4.61 11.5 11600260 4.00 4 BVV04ECV 4.61 13.1 11600270 4.00 7 BVV07ECV 4.61 15.8 21600290 4.00 12 BVV12ECV 4.61 21.5 31600300 4.00 19 BVV19ECV 4.61 25.8 31600310 6.00 2 BVV02FCV 3.08 12.2 11600320 6.00 3 BVV03FCV 3.08 13.0 11600330 6.00 4 BVV04FCV 3.08 14.7 21600360 10.00 3 BVV03GCV 1.83 14.8 21600370 10.00 4 BVV04GCV 1.83 15.8 21600400 10.00 3 BVV03HCV 1.15 18.3 21600410 10.00 4 BVV04HCB 1.15 20.1 2

51

Kewberg Cables & Braids (Pty) Ltd.

51

It is used to electrically detonate explosives

in mining operations. It has one or two PVC

insulated copper conductors. Two conductor

constructions have the conductors laid paral-

lel like lamp cord, ripcord and HPN. Blasting

wire has no voltage rating.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Mining Cables

Blasting Wire

E&OE

Applications & features

Blasting wire is used on detonation system in the mining industry. Plain solid and stranded annealed copper

conductors PVC insulated, available in various packaging and colour combinations.

Construction

Product CodeSize

(DIA) CoresCONSTRUCTION Packing (m)

1400000 0.50 2 SOLID TWIN TWISTED 100 , 300 , 600 M

1400010 0.50 2 SOLID RIPCORD 100 M

1400020 0.60 1 SOLID SINGLE CORE 1000 M

1400050 0.60 2 SOLID TWIN TWISTED 100 , 300 , 600 M

1400070 0.65 2 SOLID TWIN TWISTED 100 , 300 , 600 M

1700090 0.90 2 SOLID TWIN TWISTED 100 M

1400130 1.12 2 SOLID TWIN TWISTED 100 M

1400160 1.60 2 SOLID TWIN TWISTED

Product CodeSize

(mm2) CoresCONSTRUCTION Packing (m)

1400100 1.50 2 STRANDED TWIN TWISTED 100

1400110 1.50 2 STRANDED FIGURE 8 100

1400170 2.50 2 STRANDED FLAT TWIN 100

1400180 4.00 2 STRANDED FLAT TWIN 100

1400190 4.00 2 PVC/SWA/PVC GREEN 500 M DRUMS

Kewberg Cables & Braids (Pty) Ltd.

52

A highly flexible cable used for lighting the

miners cap lamp from the waist battery.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Mining Cables

Miners Cap Lamp Cable

E&OE

Applications & features

Construction

Flexible annealed tinned copper conductors, PVC insulated and an overall PVC sheath, very flexible sheathing

compound is chemical, oil and abrasion resistant.

The cable is manufactured according to SANS 1438 – 3

Standard Packaging—100 Metre shrink-wrapped coils.

Product CodeSize(mm)

No of Cores

Coil Length

(m)

Approx mass(Kg/100m)

ConductorResistance( Ohms/km)

Cable diameter

1800040 0.5mm2 4 cr 100 8.5 39.0 8.8

1800010 1.0mm2 2 cr 100 10.5 19.6 8.8

53

Kewberg Cables & Braids (Pty) Ltd.

53

Applied in communication and conveyor sys-

tems in the mines.

Remark: - Cables of sizes not listed above is available on request

Mining Cables

Pull Key / Pull Cord

E&OE

Applications & features

Electrical Data

Flexible stranded plain or tinned annealed copper conductor, PVC insulated, PVC bedded or polyester tape

bedding, brass plated steel wire braid, PVC sheathed. The Cable available in various conductor sizes to suit

customer requirements. Cables can also be manufactured to include braided screened cores or pairs if re-

quired. Cores and pairs are colour coded for easy identification.

Cable is also available in flame retardant PVC, low halogen PVC, halogen free PVC or polyurethane.

Construction

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v1.5mm2 12.10 300/500v2.5mm2 7.41 600/1000v

ProductCode

Size (mm²) + cr/pr Construction

MULTICORES - PVC BEDDED

3200190 0.75mm2 x 2 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200240 0.75mm2 x 3 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200340 0.75mm2 x 4 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200745 0.75mm2 x 3 pr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200570 0.75mm2 x 6 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3500600 0.75mm2 x 7 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200620 0.75mm2 x 8 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200660 0.75mm2 x 9 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200110 0.75mm2 x 12 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200150 0.75mm2 x 16 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3200740 1.0mm2 x 4 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

3200790 1.0mm2 x 5 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

3200690 1.0mm2 x 10 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

3200870 1.5mm2 x 10 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

3201030 1.5mm2 x 4 cr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

3201060 1.5mm2 x 6 cr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

3201100 1.5mm2 x 6 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

3201800 2.5mm2 x3 cr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

Kewberg Cables & Braids (Pty) Ltd.

54

Applied in communication and conveyor sys-

tems in the mines.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Mining Cables

Pull Key / Pull Cords

E&OE

Applications & features

Construction

Electrical Data

CONDUCTOR CONDUCTOR VOLTAGE

AREA RESISTANCE RATING

0.75mm2 24.50 300/500v

1.0mm2 18.10 300/500v1.5mm2 12.10 300/500v2.5mm2 7.41 600/1000v

ProductCode

Size (mm²) + cr/pr Construction

MULTICORES - POLYESTER TAPEBEDDED

3200575 0.75X6cr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath

COMBINATION CABLE - PVC BEDDED

3200480 0.75mm2x4cr+3.10mm2x2cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3200990 1.5mm2x2cr+0.75mm2x2pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath3201010 1.5mm2x2cr+0.75mm2x3pr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201470 2.5mm2x2cr+0.75mm2x4cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201610 2.5mm2x2cr+0.75mm2x6cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201700 2.5mm2x2cr+1.0mm2x4cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201840 2.5mm2x3cr+1.5mm2x3cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201850 4.0mm2x2cr+0.75mm2x4cr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath3201860 2.5mm2x4cr+0.75mm2x2pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath

COMBINATION CABLE - POLYESTERTAPE BEDDED

3200900 1.5mm2x2cr+0.75mm2x3cr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath3200970 1.5mm2x2pr+0.75mm2x2pr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath3200730 2.5mm2x2cr+1.0mm2x4cr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath3201780 2.5mm2x2cr+1.5mm2x4cr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath

CABLES WITH PLAIN COPPER BRAIDSCREENED CORES

3200280 0.75mm2x3cr + 1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3200390 0.75mm2x4cr + 2cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201300 2.5mm2x2cr+0.75mm2x2cr+1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201380 2.5mm2x2cr+0.75mm2x3cr+1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3201520 2.5mm2x2cr+0.75mm2x4cr+1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

3201600 2.5mm2x2cr+0.75mm2x5cr+1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath

55

Kewberg Cables & Braids (Pty) Ltd.

55

This is a specialized product used for submersi-

ble pumps in deep well in quarries, mines, sew-

age plants and cleaning equipment. The area of

installation is physically restrictive, and where

the environment is hostile.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Submersible Pump Cable

E&OE

Applications & features

Identification

Stranded plain annealed flexible copper conductor, flexible grade waterproof PVC insulated, (600/1000V),

cores laid and flexible grade waterproof PVC sheathed, cable in accordance with SANS1574, suitable for

temperature range of –10°C to +70°C conductors in accordance with SANS 1411 Part 1. Standard packag-

ing –500 metre drums or 100 metre coils.

Construction

Outer Sheath colours: 3 core -Blue, 4 Core –Green

Core Identification: 3 core –Red, Yellow, Blue

Core Identification: 4 core –Red, Yellow, Blue, Black

Size(mm²)

No. ofCores

NominalStranding

(No. xstrand di-ameter)

(mm)

Approx.CableDiam.(mm)

Conductorresistance @

20 °C max.(Ω/km)

Current ratingin Air @

30 °C andConductortemp. 70 °C

(A)(1 Phase)

Volt Drop(mV/A/m)

220V(1 Phase)

Volt Drop(mV/A/m)

380V(3 Phase)

Approx.Cable

weight (kg/m)

1.5 3 44/0.2 10.2 13.30 15 29 25 0.2

2.5 3 72/0.2 11.7 7.98 20 17 15 0.2

4 3 112/0.2 13.5 4.96 30 12 9.5 0.3

6 3 175/0.2 15.1 3.30 35 7.3 6.4 0.5

10 3 294/0.2 17.6 1.91 50 4.3 3.8 0.6

16 3 125/0.4 20.1 1.21 65 2.8 2.4 0.8

1.5 4 44/0.2 11.2 13.30 15 29 25 0.2

2.5 4 72/0.2 12.8 7.98 20 17 15 0.25

4 4 112/0.2 14.6 4.96 30 12 9.5 0.35

6 4 175/0.2 16.5 3.30 35 7.3 6.4 0.5

10 4 294/0.2 19.2 1.91 50 4.3 3.8 0.7

16 4 125/0.4 22.0 1.21 65 2.8 2.4 1.0

Kewberg Cables & Braids (Pty) Ltd.

56

It is a flexible cable normally used for wiring

of portable and mobile machinery. Also used

in temporary power supply on medium duty

industrial applications, workshops and ma-

chinery.

Other applications is on power supply on ar-

eas requiring oil and water resistance.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

PVC NITRILE FLEXIBLE TRAILING CABLE

E&OE

Applications & features

Stranded plain annealed flexible copper conductor, flexible grade PVC insulated and bedded (600/1000V),

cores laid up and flexible grade PVC / nitrile sheathed cable in accordance with SANS1574, suitable for a

temperature range of –10°C to +70°C conductors in accordance with SANS1411 Part 1. Standard packaging

– 500 metre drums or 100 metre coils.

Construction

Identification

Size(mm²)

No. ofCores

NominalStranding

(No. xstrand di-ameter)

(mm)

Approx.CableDiam.(mm)

Conductorresistance @

20 °C max.(Ω/km)

Current rat-ing in Air

@ 30 °C andConductortemp. 70 °C

(A)(1 Phase)

Volt Drop(mV/A/m)

380V(3 Phase)

CCG A2Cable

Gland Size

Approx. Cableweight (kg/m)

1.5 4 44/0.2 11 13.3 15 2900-20ss

0.2

2.5 4 72/0.2 13 7.98 20 171-20

0.3

4 4 112/0.2 15 4.96 30 122-25

0.4

6 4175/0.2

17 3.30 35 7.32-25

0.5

10 4294/0.2

20 1.91 50 4.32-25

0.7

16 4 125/0.4 23 1.21 65 2.82-25

1.0

Outer Sheath colours: Orange

Core Identification: 4 core –Red, Yellow, Blue, Black

57

Kewberg Cables & Braids (Pty) Ltd.

57

It is for indoor telephone installations

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

INDOOR TELEPHONE CABLE

E&OE

Applications & features

Solid annealed copper conductor (plain), PVC insulated, white PVC sheathed indoor telephone cable to

Telkom spec 268 / 271

Construction

Size(mm)

PairsNominal OD

(mm)Cable weight

(Kg / m)Total weight /1000m drum

Maximum conduc-tor loop resistance

(Ω / km)

Minimum insulationresistance (MΩ-km)

0.5 2 3.8 2 49 186.4 37.5

0.5 3 5.1 3 96 186.4 37.5

0.5 4 5.6 4 67 186.4 37.5

0.5 5 5.8 4 109 186.4 37.5

0.5 6 6.8 5 117 186.4 37.5

0.5 10 8.4 9 146 186.4 37.5

0.5 15 9.7 11 178 186.4 37.5

0.5 20 10.7 15 213 186.4 37.5

0.5 25 11.4 18 243 186.4 37.5

0.5 30 11.7 21 291 186.4 37.5

0.5 40 14.2 27 358 186.4 37.5

0.5 50 16.0 35 429 186.4 37.5

0.5 75 18.0 51 570 186.4 37.5

0.5 100 22.8 69 752 186.4 37.5

Kewberg Cables & Braids (Pty) Ltd.

58

For telephone installation , recommended for

burial

Remark: - Cables of sizes not listed above is available on request

Special Cables

OUTDOOR TELEPHONE CABLE - STEEL WIRE ARMOURED

E&OE

Applications & features

Plain annealed solid copper conductor, PVC insulated, PVC bedding sheathed, galvanised steel wire ar-

moured, PVC sheathed . Also available in flame retardant PVC, low halogen PVC and halogen free PVC.

Other constructions on request

Construction

Product Refer-ence

Size(mm)

PairsNominalOD (mm)

Cable weight(Kg / 100 m)

Totalweight /

1000m drum

Maximum con-ductor loopresistance

(Ω / km)

Minimum insu-lation resis-

tance (MΩ-km)

4300010 0.6 2 9.5 21.4 278 129.4 37.5

4300020 0.6 4 11.5 28.9 353 129.4 37.5

4300030 0.6 5 12.0 31.5 380 129.4 37.5

4300040 0.6 6 12.5 34.9 414 129.4 37.5

4300100 0.6 10 14.0 41.1 476 129.4 37.5

4300111 0.6 15 15.5 51.2 635 129.4 37.5

4300112 0.6 20 16.5 58.1 662 129.4 37.5

4300113 0.6 30 18.0 67.2 730 129.4 37.5

4300114 0.6 40 20.0 85.8 553 129.4 37.5

4300115 0.6 51 24.0 124.0 852 129.4 37.5

4300130 0.9 4 13.0 36.9 450.0 55.8 37.5

4300140 0.9 5 14.0 42.0 485.0 55.8 37.5

4300150 0.9 6 14.5 46.1 543.0 55.8 37.5

4300160 0.9 10 16.0 57.9 661.0 55.8 37.5

4300161 0.9 15 18.5 74.2 453.0 55.8 37.5

4300162 0.9 20 19.5 86.4 514.0 55.8 37.5

4300163 0.9 30 24.5 136.3 805.0 55.8 37.5

4300164 0.9 40 26.5 160.2 970.0 55.8 37.5

4300165 0.9 51 29.5 192.3 1194.0 55.8 37.5

59

Kewberg Cables & Braids (Pty) Ltd.

59

The cables are used in security system instal-

lations. They are widely applied in commer-

cial, domestic and industrial buildings and in

public ways.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Security Cables—Solid and Stranded Multicores, Ripcords and Cabtyres

E&OE

Applications & features

Solid conductors: Colour coded solid copper PVC insulated and PVC sheathed, available in white, brown

and black.

Construction

Product Code Size (DIA)Cores

Nominal OD(mm)

± Kg / 100m Packing (m)

3500170 0.45 4 1.2 100

3500180 0.45 6 1.8 100

3500190 0.45 8 2.4 100

3500200 0.45 10 3.0 100

3500210 0.45 12 3.6 100

3500220 0.45 16 4.0 100

3500230 0.45 20 5.4 100

3500240 0.45 30 8.0 100

Product Code Size (mm2) CoresNominal OD

(mm)± Kg / 100m Packing (m)

3500390 0.20 4 2.0 100

3500400 0.20 6 2.6 100

3500410 0.20 8 3.2 100

3500420 0.20 10 3.8 100

3500430 0.20 12 4.6 100

3500440 0.20 20 8.0 100

3500450 0.20 30 12.0 100

Stranded conductors: Colour coded multi stranded copper conductors PVC insulated and PVC sheathed,

available in white, brown and black.

Kewberg Cables & Braids (Pty) Ltd.

60

The cables are used in security system instal-

lations. They are widely applied in commer-

cial, domestic and industrial buildings and in

public ways

Ripcords

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Security Cables—Solid and Stranded Multicores, Ripcords and Cabtyres

E&OE

Applications & features

Solid annealed plain copper conductor, PVC insulated, aluminium/ mylar foil screened, tinned stranded cop-

per drain wire, flame retardant PVC sheathed (red or white)

Construction—Light Duty Cabtyre

Product Code Size (mm2)

Cores

Nominal OD(mm)

± Kg / 100m Packing (m)

0.50 3 4.0 100

Product CodeSize

(mm2)Cores

Nominal OD(mm)

± Kg / 100m Packing (m)

3500390 0.20 2 1.0 100

3500400 0.40 2 1.6 100

3500410 0.50 2 2.2 100

61

Kewberg Cables & Braids (Pty) Ltd.

61

Wiring of fire alarms, fire protective circuits,

burglar alarms, smoke alarms, and voice

communications

Stranded annealed plain copper conductor, PVC insulated, aluminium/mylar foil screened tinned stranded

copper drain wire, flame retardant PVC sheathed (red or white).

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Fire Alarm Cables

E&OE

Applications & features

Solid annealed plain copper conductor, PVC insulated, aluminium/ mylar foil screened, tinned stranded

copper drain wire, flame retardant PVC sheathed (red or white)

Construction

Product CodeSize(DIA)

No of pairs /coresNominal OD

(mm)± Kg / Km Packing (m) Gland Size

2100010 0.80 2 cr 4.0 83 1000 00

2100020 0.80 4 cr 4.9 94 1000 00

2100030 0.80 8 cr 6.5 134 1000 00

2100060 1.12 2 pr 6.4 98 1000 00

Product CodeSize

(mm2)Cores

Nominal OD(mm)

± Kg / Km Packing (m) Gland Size

2100075 1.00 25 6.0 90 1000 00

2100080 1.50 30 7.0 103 1000 00

Kewberg Cables & Braids (Pty) Ltd.

62

A higher wattage, heavy-duty cable system

that is designed to be installed within the

concrete screed of a new building or exten-

sion. A very cost-effective solution for new

home constructions

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Underfloor Heating Cable

E&OE

Applications & features

Galvanised steel wire with or without a solid plain copper wire supplied in various colours each with differ-

ent conductor resistance and packaging lengths for various heating applications. All wire insulated with a

high temperature PVC.

Construction

Product Code Colour

NominalOverall di-mension

(mm)

Cu (Dia)Galvanised

Steel Wire( Dia)

Meters per CoilMaximum conductor

resistance(Ω / Coil at 20°C)

4500010 Grey 4.00 3x0.30mm 1000 608.00

4500020 White 4.00 0.25 3x0.30mm 100 22.10

4500030 Violet 4.00 0.31 3x0.30mm 165 27.80

4500030 Violet 4.00 0.31 3x0.30mm 250 42.10

4500060 Yellow 4.00 0.45 3x0.30mm 200 18.65

4500060 Yellow 4.00 0.45 3x0.30mm 210 19.60

4500070 Orange 4.00 0.55 3x0.30mm 250 16.35

4500070 Orange 4.00 0.55 3x0.30mm 375 24.50

4500080 Red 4.00 0.76 3x0.30mm 330 12.10

4500080 Red 4.00 0.76 3x0.30mm 500 18.30

4500090 Dark Green 4.00 0.85 3x0.30mm 370 10.90

4500100 Pink 4.00 4x0.30mm 100 45.60

4500100 Pink 4.00 4x0.30mm 110 50.20

4500100 Pink 4.00 4x0.30mm 200 91.20

63

Kewberg Cables & Braids (Pty) Ltd.

63

RUNWAY LIGHTING CABLE is designed for

burial beside runways, to power the lights that

guide aircraft to safe landings and take offs.

It has a thick covering of polyethylene and a

shielding of tinned copper braid.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Runway Lighting Cable

E&OE

Applications & features

The conductor comprises single 6mm2 cross-sectional area multi strand tinned annealed copper wire.

Polyethylene insulation provides the cable with superior electrical and mechanical characteristics, screened

with tinned copper braid and sheathed with a flame retardant PVC.

Construction

Kewberg Cables & Braids (Pty) Ltd.

64

Cables for elevators and cranes (Internal and

Panoramic).

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Flat Elevator / Crane Cable

E&OE

Applications & features

Flat crane cable has flexible copper conductors class 5 annealed copper conductors, 4core cable is colour

coded blue, brown, yellow/green earth conductor. The sheath is a flexible grade PVC.

Construction

Product Code Size (mm²) No. Of CoresCable Dia (Width x

Height)Kg/1000m

2200010 1.5mm2 4 15x5 200.0

2200020 1.5mm2 8 28x5 600.0

2200030 1.5mm2 12 40x5 950.0

2200040 2.5mm2 4 18x5.8 290.0

2200050 2.5mm2 8 37x5.8 740.0

2200060 2.5mm2 12 50x5.8 1260.0

2200070 4.0mm2 4 21x6.8 410.0

2200080 4.0mm2 7 38x6.9 750.0

2200100 6.0mm2 4 24x7.6 520.0

2200110 10.0mm2 4 30x9.6 800.0

2200120 16.0mm2 4 24.5x10.9 1150.0

2200130 25.0mm2 4 41.5x12.5 1800.0

2200140 35.0mm2 4 49x15.8 2200.0

65

Kewberg Cables & Braids (Pty) Ltd.

65

The cable is used for overhead crane control

system

They are built to withstand mechanical stress

wihile allowing for control.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Pendant Crane Cable

E&OE

Applications & features

Electrical Data

Crane pendant cable consists of plain annealed copper, black PVC insulated conductors with green, yellow

earth. The cable is strengthened by 2 steel wire ropes extruded in the outer PVC sheath.

Construction

Product CodeSize

(mm²)No. Of Cores

Cable Diameter (Widthx Height)

Kg/1000m

2200150 1.0mm2 14 16X26 400

2200160 1.0mm2 27 22X34 700

2200170 1.5mm2 8 16X28 420

2200180 1.5mm2 12 17X28 510

2200190 1.5mm2 20 21X34 720

Kewberg Cables & Braids (Pty) Ltd.

66

Seismic cable is used for seismic detection

devices mainly used in mines to monitor

breaths and slips of the earths tectonic

plates.

Remark: - Cables of sizes not listed above is available on request

Diameter and weights are representative figures and may vary by +- 5%

Special Cables

Seismic Detection Cable

E&OE

Applications & features

Plain annealed solid copper conductor, polyethylene insulated, either individual or overall screening with a

tinned copper drain wire, PVC bedding, galvanised steel wire armoured and PVC sheathed. The outer

sheath can be flame retardant PVC, low halogen or halogen free PVC.

Construction

Product Code Size (mm) Pairs Drum LengthApprox mass

(Kg)Conductor Resis-tance ( Ohms/km)

Cable diameterGlandSize

OVERALLSCREENED

3600180 0.8 2 pr 500 240 36.0 13.8 0

3600190 0.8 4 pr 500 288 36.0 15.5 0

3600200 0.8 6 pr 500 345 36.0 17.0 1

3600210 0.8 8 pr 500 398 36.0 18.5 1

3600220 0.8 10 pr 500 480 36.0 19.9 2

3600230 0.8 12 pr 500 560 36.0 21.2 2

3600240 0.8 20 pr 500 852 36.0 24.2 2

3600250 0.8 32 pr 500 1010 36.0 28.5 3

INDIVIDUALSCREENED

3600010 0.8 2 pr 500 260 36.0 14.4 0

3600020 0.8 4 pr 500 305 36.0 15.9 0

3600030 0.8 6 pr 500 365 36.0 17.6 1

3600040 0.8 8 pr 500 440 36.0 19.5 2

3600050 0.8 10 pr 500 510 36.0 21.1 2

3600060 0.8 12 pr 500 590 36.0 22.0 2

3600070 0.8 20 pr 500 890 36.0 26.6 3

3600080 0.8 32 pr 500 1050 36.0 32.8 4

67

Material

Insulation Material

Chemical description

Short

symbol

accordin

g to DIN

76722

Classi-

fication

acc. to

ISO

6722

Continuou

s duty

temp.

(3.000 h)

°C

Thermal

overload

capacity

°C / 48 h

Cold

bending

resistanc

e °C

Specific

resistance

at 20 °C

Ω x cm

Shore

hardnes

s A/D

Tensile

strength

MPa

Elongation

at break

% Abrasion

Flame

retardant Oil Fuel

Brake

Fluid

Acid/

Lye

Organic

compound

s

PVC Polyvinyl Chloride Y (YW) A/B 90 / 105 140 -40 > 10¹² A85-95 > 10 > 150 + + + + - + -

XPVC

Irradiation cross-linked

PVC-compounds X A/B 90 / 105 140 -40 > 10¹² A85-95 > 10 > 150 ++ + + + + + +

PE Polyethylene 2Y B 100 100 -50 > 1016

D45-55 > 15 > 300 + -- - + - ++ -

TPE-E

Thermoplastic Polyester-

Elastomer Hytrel® 13Y C 110 150 -40 > 1010

D40-78 > 25 > 300 ++ - ++ ++ + - +

TPE-U

(PUR)

Thermoplastic

Polyurethane-Elastomer

Elastollan® 11Y C 125 150 -50 > 109

A75-D54 > 30 > 300 ++ - ++ ++ + + +

XPE

Irradiation cross-linked

PE-compounds 2X C/D 125 200 -40 >1013

A95-D50 >10 >100 + + + + + + +

EVA

Ethylene-Vinylacetate-

Copolymer-compounds 4G C 130 160 -40 >1013 A80-90 > 10 > 200 + - + + + + +

HX

Irradiation cross-l inked

Copolymer-compounds – D 150 200 -40 > 1011

A92 > 10 > 100 + + + + + + +

XTPE-E

Irradiation cross-l inked

Polyester-Elastomer-

compounds 12X D 150 200 -40 >1011

A88 >15 >200 +/- + ++ ++ ++ ++ ++

PVDFPolyvinylidenfluorid

Dyflor® Kynar® 10Y D 155 160 -65 >1014 D75-80 > 20 > 100 ++ +(+) ++ ++ ++ ++ +

ETFE

Ethylen-Tetrafluor-

ethylen-Copolymer

Hostaflon®-ET Tefzel® 7Y E 180 230 -65 >1016

D75-80 > 30 > 150 ++ +(+) ++ ++ ++ ++ ++

FEP

Perfluorethylen-

propylen-Copolymer

Hostaflon®-FEP Teflon®-

FEP 6Y F 210 240 -65 >1016 D55-60 > 15 > 200 ++ ++ ++ ++ ++ ++ ++

PFA

Perfluoralkoxy-

Tetrafluorethylenco-

polymer Hostaflon®-PFA

Teflon®-PFA 14Y H 260 270 -65 >1017

D55-65 > 20 > 200 ++ ++ ++ ++ ++ ++ ++

PTFE

Polytetrafluorethylene

Hostaflon®-TF Teflon®-

PTFE 5Y H 260 310 -65 >1017 D55-65 > 20 > 200 ++ ++ ++ ++ ++ ++ ++DuPontRegisteredTradeMarks: Othertrademarks

Hytrel,Teflon,Tefzel Elastollanisaregisteredtrademark ofElastogranGmbH Dyfloris aregistred trademarkof Evonik(previouslyDegussa)

HostaflonisaregisteredtrademarkofHoechst,Germany. Kynarisa registeredtrademarkof ArkemaInc.

Thermal Properties Resistance to various:

PRODUCTS ANY CABLE AND CABLE RELATED PRODUCTS NOT LISTED IN THIS CATALOGUE

SOURCING SOURCING OF CABLE & RELATED PRODUCTS, LOCALLY AND INTERNATIONALLY

SERVICES OVER-SHEATHING & ARMOURING OF EXISTING CABLES WITH THE FOLLOWING

SHEATHING WITH THE FOLLOWINGFR (Flame Retardant),

LH (Low Halogen, Blue stripe),ZH (Zero Halogen, White stripe)

ARMOURING WITH THE FOLLOWINGSWA (Steel Wire Armour)

APL ( Aluminium-Polyethylene-Laminate)AVL (Aluminium-Vinyl-Laminate ) in FR, LHFR and ZHFR

FR Flame Retardant

LH Low Halogen

LHFR Low Halogen Flame Retardant

ZH Zero Halogen

HFFR Halogen Free Fire Retardant

SWA Steel Wire Armour

APL Aluminium-Polyethylene-LaminateAVL Aluminium-Vinyl-LaminateOAM Overall Mylar* (Screen)IOAM Individual and Overall Aluminium / Mylar* (Screen)TCB Tinned Copper Braid

PCB Plain Copper Braid

D/W Drain Wire

PVC Poly Vinyl Chloride

XLPE Cross Linked Polyethelen

PE Polyethelene

TC Tinned Copper

PC Plain Copper

PR Pairs

C Cores

TR Triads

STR Stranded

PC Plain Copper Cores

1.5mm² Size of the conductors

4 Qty of Conductors

Pr Conductors in a Twisted Pair Construction

XLPE Cross linked Polyethelene insulation

IOAM Ind ividual and Over All Mylar (Screen)

D/W Drain Wire

SWA Steel Wire Armour

HFFR Halogen Free Fire Retardant oversheath

1.5mm² x 4 PR STR PC XLPE IOAM + D/W SWA HFFR

MEASURING RE-MEASURING AND RE-DRUMMING OF CABLE

OTHER PRODUCTS AND SERVICES

MANUFACTURING OF SPECIAL CABLESSpecial cables can be manufactured according to your specifications.

Composite Cables can be manufactured according to your specifications and requirements

TYPICAL CABLE ABBREVIATIONS

TYPICAL CABLE CONSTRUCTION DETAILS

69

CONDUCTOR STRANDING TO VDE 0295 & IEC 60228

Crosssection(mm²)

Conductor stranding toDIN VDE 0295 Class 2

No. of wires / wire di-ameter

Multi-Conductorstranding to

VDE 0295No. of wires / wire

diameter

Conductor strandingto VDE 0295

Class 5No. of wires / wire

diameter

Superfine Conductorstranding to VDE

0295 Class 6No. of wires / wire

diameter

0.14 18/0.10

0.25 14/0.15 32/0.10

0.34 7/0.25 19/0.15 42/0.10

0.5 7/0.3 7/0.3 16/0.2 28/0.15

0.75 7/0.37 7/0.37 24/0.2 42/0.15

1 7/0.43 7/0.43 32/0.2 56/0.15

1.5 7/0.52 7/0.52 30/0.25 84/0.15

2.5 7/0.67 19/0.41 50/0.25 140/0.15

4 7/0.85 19/0.52 56/0.30 224/0.15

6 7/1.05 19/0.64 84/0.30 192/0.2

10 7/1.35 49/0.51 80/0.40 320/0.2

16 7/1.70 49/0.65 128/0.40 512/0.2

25 7/2.13 84/0.62 200/0.40 800/0.2

35 7/2.52 133/0.58 280/0.40 1120/0.2

50 19/1.83 133/0.69 400/0.40 705/0.3

70 19/2.17 189/0.69 356/0.50 990/0.3

95 19/2.52 259/0.69 485/0.50 1340/0.3

120 37/2.03 336/0.67 614/0.50 1690/0.3

150 37/2.27 392/0.69 765/0.50 2123/0.3

185 37/2.52 494/0.69 944/0.50 1470/0.4

240 61/2.24 627/0.7 1225/0.50 1905/0.4

300 61/2.5 790/0.7 1530/0.50 2385/0.4

400 61/2.89 2035/0.50

500 61/3.23 1768/0.60

630 91/3.23 2286/0.60

Kindly note that in accordance with VDE 0295 only the maximum diamemeter and resistance of the conductor is specified

AMERICAN WIRE GUAGE TO ACTUAL METRIC AREA (mm²) & CONDUCTOR RESISTANCE

AWG /MCM num-

ber

Conductor Cross-sectional area

(mm²)

Conductor diameter(mm)

Conductor resistance(Ω / km)

AWG number

ConductorCross-

sectionalarea (mm²)

Conductordiameter

(mm)

Conductorresistance

(Ω / km)

1000 MCM 507 29.3 0.036 15 1.65 1.45 11.2

900 MCM 456 27.8 0.04 16 1.31 1.29 14.7

750 MCM 380 25.4 0.048 17 1.04 1.15 17.8

600 MCM 304 22.7 0.061 18 0.823 1.024 23

550 MCM 279 21.7 0.066 19 0.653 0.912 28.3

500 MCM 253 20.7 0.07 20 0.519 0.812 34.5

450 MCM 228 19.6 0.08 21 0.412 0.723 44

400 MCM 203 18.5 0.09 22 0.324 0.644 54.8

350 MCM 177 17.3 0.1 23 0.259 0.573 70.1

300 MCM 152 16 0.12 24 0.205 0.511 89.2

250 MCM 127 14.6 0.14 25 0.163 0.455 111

4/0 107.2 11.68 0.18 26 0.128 0.405 146

3/0 85 10.4 0.23 27 0.102 0.361 176

2/0 67.4 9.27 0.29 28 0.0804 0.321 232

1/0 53.4 8.25 0.37 29 0.0646 0.286 282

1 42.4 7.35 0.47 30 0.0503 0.255 350

2 33.6 6.54 0.57 31 0.04 0.227 446

3 26.7 5.83 0.71 32 0.032 0.202 578

4 21.2 5.19 0.91 33 0.0252 0.18 710

5 16.8 4.62 1.12 34 0.02 0.16 899

6 13.3 4.11 1.44 35 0.0161 0.143 1125

7 10.6 3.67 1.78 36 0.0123 0.127 1426

8 8.34 3.26 2.36 37 0.01 0.113 1800

9 6.62 2.91 2.77 38 0.00795 0.101 2255

10 5.26 2.59 3.64 39 0.00632 0.0897 2860

11 4.15 2.3 4.44 39 0.00632 0.0897 2860

12 3.31 2.05 5.41 40 0.00487 0.079 3802

13 2.63 1.83 7.02 42 0.00317 0.064 584214 2.08 1.63 8.79 44 0.00203 0.051 9123

Note: 1 CM = 1 Circ. Mil = 0.0005067 mm² and 1 MCM = 1000 Circular mils = 0.5067 mm²

71

Phone: +27 (0 11) 908 5165

Fax: +27 (0 11) 864 6812

Fax: +27 (0 11) 908 1261

E-mail: [email protected]

9 Clarke Street

Alrode, Alberton

1450

Johannesburg, South Africa

P O Box 124379,

Alrode, 1451

Alberton, South Africa

Kewberg Cables & Braids (Pty) Ltd.

A subsidiary of