Kewberg Cables & Braids (Pty) Ltd.
9 Clarke Street
Alrode, Alberton
1450
Johannesburg, South Africa
Phone: +27 (0 11) 908 5165
Fax: +27 (0 11) 864 6812
Fax: +27 (0 11) 908 1261
E-mail: [email protected]
Products Catalogue
Kewberg Cables, a subsidiary of the TransCentury Group, is a leading manufacturer of
cables. The company’s customer base includes power supply authorities, railway and
transport organisations, municipalities, and companies in industries such as petrochemi-
cal, mining, wholesale, industrial, construction and domestic building. The company
manufactures and sells a wide range of state of the art products with customer specific
adaptation, design capabilities and full technical back-up service.
Kewberg Cables prides its self on its ability to identify and satisfy customer needs through
development of innovative products; unique, cost effective cable solutions for a wide
range of industries
Technology focus
Kewberg Cables pursues ongoing technology developments through active association
with its local and overseas affiliates. This has enabled the company to remain at the
forefront of technology.
The company has been recognised as a pioneer and leader in specialised cable ad-
vancements in South Africa. Kewberg serves on a number of South African Bureau of
Standards Committees.
Quality focus
Kewberg Cables is a fore runner in the industry with regard to quality.
The manufacturing, quality assurance, are of a world-class standard. In fact the com-
pany has been awarded ISO 9001 compliance certificate.
These quality assurance systems are applied to all the phase of manufacturing process,
likewise ensure the perfect operation of the cable, in accordance with the purpose for
which it was developed.
Customer focus
Customer satisfaction through attention and service are the key pillars on which the com-
petitive strategy of Kewberg Cables is based. We aim at a level of agility and flexibility of
our factory to enable the speedy manufacture of cables that are not kept in stock
5
1 Instrumentation And Control Cable
A wide range of paired and multicore cables which are XLPE insulated .
the cables are screened with an aluminium/mylar tape which gives
protection against interference .
Paired cables can be overall or individually and overall screened .
multicore cables are overall screened .
The standard range is sheathed with flame retardant pvc but can also
be done with low halogen and halogen free compounds .
The whole range can be done in steel wire armoured , APL, FR or unar-
moured .
2 Power Cables
A range of power cables from 2 cores - 37 cores are manufactured to sans
1507 .
These cables are sheathed with flame retardant , low halogen and
halogen free compounds . Various sizes of cabtyre are also manufactured .
3 Pull-Cord Cables
These cables are primarily used for conveyer belt systems on mines .
A wide variety of conductor configurations to suit customer
requirements are protected with a brass plated steel braid , offering
a high tensile , abrasion resistant and mechanically strengthened cable .
4 Cap Lamp Cable
Kewberg cables is the sole manufacture of cap lamp cable in South Africa .
the cables are used on miners cap lamps and are super flexible and
chemical , oil , and abrasion resistant .
5 Security Cables
These cables are used for alarm and burglar detection systems . Kewberg
manufactures a wide range of solid and stranded communication cables
in white , brown and black . Ripcords in various sizes and colours are also
supplied .
6 Blasting Wire
Blasting wire is manufactured specifically for detonation systems used
in the mining industry . These cables are manufactured in various sizes and
colours .
7 Defence Standard Cable
Manufactured to defence standard 61/12 part 4 and 5 . These cables are
supplied in multicore and paired constructions with foil or braid screen .
8 Airfield Lighting Cable .
Airfield lighting cable is used exclusively for the lighting of runways in
commercial and military airports .
9 Specialised Cables
Kewberg cables also manufactures a wide range of specialised cables in
various constructions .
Conductors - plain or tinned copper either solid or multistrand .
Insulation - polyethylene , cross linked polyethylene ( XLPE ) and various
grades of PVC .
Screening - aluminium/mylar foil and plain or tin copper braid .
Sheathing materials - flame retardant , low halogen and halogen free pvc
as well as polyethylene , polyurethane and nitrile outer sheaths can be supplied .
Protection - cable can be protected with galvanised steel wire , galvanised
steel wire braid , brass plated steel wire braid or aluminium polyethylene
laminate ( APL-FR ) .
Our range of specialised cables include underfloor heating cable , speed
trap cable , microphone cable , telephone cables , fire alarm cable , seismic
cable , illumination cable and a variety of single core cables .
7
2| Control Cables
1| Instrumentation Cables
3| Defence Specification Cables
4| Power Cables
5| Mining Cables
6| Special Cables
9
KEWBERG manufactures and supplies a wide range of Instrumentation cables, which are
made using superior raw materials. These Instrumentation Cables are extensively used in
data acquisition systems, process control and computer networking, public address sys-
tems and digital control, measuring & communication systems.
We manufacture and stock a comprehensive range of Screened Instrumentation Cables,
which are used in signalling systems, control and instrument circuits.
These Cables also report and monitor process variables ranging from transducers to en-
vironmental controls and computer inputs. Maximum rejection of electromagnetic noise is
achieved by twisting the insulated conductors. Twisting causes the noise to be cancelled
in adjacent sections of the wire.
Maximum electrostatic noise rejection is achieved by shielding the cable with aluminium
foil tape.
A minimum of 25% overlap of the shield ensures 100% coverage even when the cable is
flexed. The drain wire under the shield provides continuous low resistance path to ground
and simplified hook-up at grounding terminals.
These Cables can also be provided with aluminium polyethylene laminate (APL) and steel
wire armouring (SWA).
Ease of installation is another major benefit of these Cables. Individual cores, pairs, tri-
ads or quads are colour coded and or number printed.
A pair of Communication Wires can also be provided. The Cables are available in a wide
range of insulation and jacket materials, the most popular being PVC, Polyethylene, FR
PVC, LHcL PVC or HFFR PVC.
Construction
Conductor
Bare (plain) or tinned electrolytic annealed copper conductor. Solid, stranded or flexible.
Insulation
Either XLPE, PVC or PE insulation in accordance with SABS 1411 as required.
Twisting and Laying
Required numbers of cores are laid up in case of multi-core core cables. Individual pairs, triads or
quads are formed by uniformly twisting the insulated cores with required lay lengths, prior to laying.
Core Identification
Cores can be colour coded or number printed for easy identification. In case of multi pair cables
both cores in each pair is alpha numerically at short intervals, individual screens are also printed.
Overall Screen
After final lay up of the complete cable an overall screen of aluminium-polyester tape is applied
along with 0.5 sqmm multi stranded annealed tinned copper (ATC) drain wire in continuous electrical
contact with aluminium side of the tape.
Individual & Overall Screen
Individual pairs, triads or quads are screened by aluminium-polyester tape along with 0.5 sqmm an-
nealed tin copper drain wire and overall screened by aluminium-polyester tape as mentioned above.
Tinned copper braid screening can also be used for individual screen.
In case of individually screened cables for critical applications an extruded isolation sheath can also
be provided over the individual screens.
Assembly Binder
After final assembly PVC or PE is provided as required to act as a binder as well as bedding for the
outer screening in all cables.
Armour
Galvanized steel wire or a flame retardant aluminium polyethylene laminate.
Inner & Outer Sheath
PVC, HFFR, LHCL PVC or FR PE sheath can be provided. U.V stabilized Polyethylene sheath can
also be provided for hazardous areas. A blue colour outer sheath for intrinsically safe areas can be
provided on request. A communication wires can be provided if desired.
Rip Cord
To simplify jacket removal, high tensile strength nylon Rip Cord is provided over laid up of pairs/
triads/quads below the outer sheath in case of unarmoured cable or below the Inner Sheath in case
of armoured Cable.
Quality Assurance
Quality Standards are built in every Kewberg Cables product. Our cables are subjected to a series of
required tests in our well-equipped laboratory. Besides the rigid tests and checks at every stage from
raw material through manufacturing stages and finally up to the finished product.
Being an ISO 9001: 2008 certified company, our quality management standards conform to highest
standards quality assurance practices.
11
Kewberg Cables & Braids (Pty) Ltd.
11
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Remark: - Cables of sizes not listed above is available on request
Instrumentation Cables
Multi-pairs—XLPE Insulated, Overall screened
E&OE
Applications & features
Plain annealed multi stranded coper conductor, cross linked polyethylene (XLPE) insu-
lated, cores twisted into pairs. The cores are black and white. Each core is alpha nu-
merically numbered. The cable is overall foil screened with a tinned copper drain wire. The sheath can be
flame retardant PVC low halogen or halogen free compound in black or coloured on request.
Construction
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km
Product CodeSize
(mm²)Pairs
Nominal OD(mm)
Minimumbendingradius(mm)
± Kg / KmCCG A2
Gland Size
Standarddrum length
(m)
Gross drumweight (Kg)
PAIRS
2500440 0.5 1 5.6 51 42 00 1000 912500450 0.5 2 8.9 81 88 0 1000 1532500460 0.5 4 10.6 96 128 0 1000 2032500480 0.5 8 13.3 121 212 1 1000 2992500490 0.5 12 15.8 143 282 2 500 2162500500 0.5 16 17.5 158 350 2 500 2502500520 0.5 24 20.3 183 491 2 500 3332500530 0.5 36 24.8 224 710 3 500 3752500550 1.0 1 6.4 58 60 00 1000 1092500560 1.0 2 10.8 98 131 0 1000 2062500570 1.0 4 12.4 112 183 1 1000 2582500580 1.0 8 16.1 146 315 2 1000 4772500590 1.0 12 18.7 169 428 2 500 2852500600 1.0 16 21.1 190 562 3 500 3682500620 1.0 24 24.1 217 772 3 300 3942500630 1.5 1 7.2 66 73 00 1000 1382500640 1.5 2 12.4 112 166 00 1000 2412500650 1.5 4 14.7 132 247 1 1000 3342500660 1.5 8 18.6 168 407 2 500 2752500670 1.5 12 22.1 199 582 3 500 4532500680 1.5 16 24.9 224 760 3 300 3902500700 1.5 24 28.4 256 1050 4 300 477
Kewberg Cables & Braids (Pty) Ltd.
12
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Triads—XLPE Insulated, Overall screened
E&OE
Applications & features
Plain annealed multi stranded coper conductor, cross linked polyethylene (XLPE) insu-
lated, cores twisted into triads. The cores are black, white and red. Each core is alpha
numerically numbered. The cable is overall foil screened with a tinned copper drain wire. The sheath can be
flame retardant PVC low halogen or halogen free compound in black or coloured on request.
Construction
Product CodeSize
(mm²)Triads
Nominal OD(mm)
Minimumbendingradius(mm)
± Kg / KmCCG A2
Gland Size
Standarddrum length
(m)
Gross drumweight (Kg)
TRIADS
2500990 0.5 1 5.9 54 51 00 1000 1002501010 0.5 4 11.8 107 164 1 1000 2392501020 0.5 8 15.7 141 280 2 1000 3672501030 0.5 12 18.8 169 383 2 500 2632501040 0.5 16 21.2 191 502 3 500 4132501055 0.5 24 26.5 239 726 3 300 3802501558 0.5 36 30.6 273 999 4 300 4622501060 1.0 1 6.8 61 72 00 1000 1212501080 1.0 4 14.3 129 255 1 1000 3422501090 1.0 8 18.3 167 428 2 500 2852501100 1.0 12 22.5 205 620 3 500 4722501110 1.0 16 25.4 229 809 3 300 4052501120 1.5 1 7.7 69 90 00 1000 1552501140 1.5 4 16.4 148 325 2 1000 4872501150 1.5 8 21.8 197 580 2 500 4522501160 1.5 12 26.8 241 841 3 300 414
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km
13
Kewberg Cables & Braids (Pty) Ltd.
13
It is used for transmission of analogue and
digital signals in process control systems. It
will be used for indoor and outdoor installation,
in dry and wet locations, on racks, and in con-
duits. Not allowed for direct connection to low
impedance source. It is not recommended for
direct burial.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Pairs—XLPE Insulated, Individual and Overall screened, Unarmoured
E&OE
Applications & features
Plain annealed multi stranded copper conductor, cross-linked polyethylene (XLPE)
insulated. Cores twisted into pairs. Each pair is foil screened with it ’s own tin copper
drain wire. For each pair, the cores are black and white. Each core and all screens are alpha numerically
numbered. The cable is overall foil screened with tinned copper drain wire. The sheath can be flame retar-
dant PVC low halogen or halogen free compound in black or coloured on request.
Construction
Product CodeSize
(mm²)Pairs
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Gross drumweight (Kg)
PAIRS
2500720 0.5 2 9.7 87 109 0 1000 1742500730 0.5 4 11.0 99 159 0 1000 2342500740 0.5 8 14.3 130 273 1 1000 3482500750 0.5 12 16.9 152 347 2 500 2492500760 0.5 16 19.4 175 458 2 500 3162500780 0.5 24 22.9 207 627 3 500 4782500790 0.5 36 27.6 249 907 4 500 698
2500810 1.0 2 11.1 101 148 0 1000 2232500820 1.0 4 12.8 115 213 1 1000 2882500840 1.0 8 16.7 151 377 2 1000 5392500860 1.0 12 20.2 182 544 2 500 3592500870 1.0 16 22.9 206 691 3 500 5082500890 1.0 24 27.4 247 998 4 500 743
2500920 1.5 2 12.7 115 183 1 1000 2582500930 1.5 4 15.0 136 297 2 1000 3842500940 1.5 8 19.7 178 494 2 500 3342500950 1.5 12 23.3 210 685 3 500 5052500960 1.5 16 26.8 242 903 4 300 4332500980 1.5 24 32.2 290 1305 4 300 554
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km
Kewberg Cables & Braids (Pty) Ltd.
14
It is used for transmission of analogue and
digital signals in process control systems. It
will be used for indoor and outdoor installa-
tion, in dry and wet locations, on racks, and
in conduits. Not allowed for direct connection
to low impedance source. It is not recom-
mended for direct burial.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Triads—XLPE Insulated, Individual and Overall screened, Unarmoured
E&OE
Applications & features
Plain annealed multi stranded copper conductor, cross-linked polyethylene (XLPE)
insulated. Cores twisted into triads. Each triad is foil screened with it ’s own tin copper
drain wire. The cores for the triads are black, white and red. Each core and all screens are alpha numeri-
cally numbered. The cable is overall foil screened with tinned copper drain wire. The sheath can be flame
retardant PVC low halogen or halogen free compound in black or coloured on request.
Construction
Product CodeSize
(mm²)Triads
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Gross drumweight (Kg)
TRIADS
2501180 0.5 4 12.2 110 189 1 1000 2642501190 0.5 8 16.2 146 330 2 1000 4922501210 0.5 12 19.8 179 479 2 500 3272501220 0.5 16 22.0 198 599 3 500 4622501230 0.5 24 27.5 248 872 4 300 4242501235 0.5 36 32.1 286 1248 4 300 536
2501250 1.0 4 14.7 132 286 2 1000 3732501260 1.0 8 19.2 175 509 2 500 3422501270 1.0 12 23.3 210 712 3 500 5182501280 1.0 16 26.1 237 931 3 300 441
2501320 1.5 4 16.8 152 348 2 1000 5102501330 1.5 8 22.3 202 645 3 500 4852501340 1.5 12 27.4 247 929 4 300 441
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km
15
Kewberg Cables & Braids (Pty) Ltd.
15
It is used for transmission of analogue and
digital signals in process control systems. It
will be used for indoor and outdoor installa-
tion, in dry and wet locations, on racks, and
in conduits. Not allowed for direct connection
to low impedance source. It is recommended
for direct burial.
Remark: - Cables of sizes not listed above is available on request
Instrumentation Cables
Multi-Pairs—XLPE Insulated, Overall screened , Steel Wire armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XPLE)
insulated, cores twisted into pairs. For paired cable the cores are black and white.
Each core is alpha numerically numbered. The cable is overall foil screened with a tinned copper drain wire.
The cable is supplied with a bedding sheath and is armoured with galvanised steel wire for protection. The
sheath can be flame retardant PVC, low halogen or halogen free compound in black or coloured on request.
Construction
Product CodeSize
(mm²)Pairs
Nominal OD(mm)
Minimumbending ra-
dius (mm)
± Kg / KmCCG BW
Gland Size
Standarddrum length
(m)
Gross drumweight (Kg)
PAIRS
2503150 0.5 1 10.5 106 249 0 1000 3242503160 0.5 2 13.8 139 394 0 1000 4812503170 0.5 4 15.5 155 486 0 1000 5732503190 0.5 8 18.6 187 651 1 1000 7972503200 0.5 12 21.1 212 810 2 500 5672503210 0.5 16 22.8 228 930 2 500 6272503230 0.5 24 26.3 263 1323 2 500 9062503235 0.5 32 29.3 294 1589 3 500 10392503240 0.5 36 32.0 320 1903 3 300 733
2503260 1.0 1 11.3 114 290 0 1000 3652503270 1.0 2 15.7 158 489 0 1000 5762503280 1.0 4 17.3 174 589 1 1000 7512503290 1.0 8 21.4 215 857 2 1000 10032503300 1.0 12 24.7 247 1199 2 500 7622503310 1.0 16 27.1 271 1418 3 500 9532503330 1.0 24 31.3 313 1986 3 300 758
2503340 1.5 1 12.1 122 329 0 1000 4042503350 1.5 2 17.3 173 572 1 1000 7342503360 1.5 4 20.0 200 738 2 1000 8842503370 1.5 8 24.6 247 1177 2 500 7512503380 1.5 12 28.5 285 1510 3 500 9992503390 1.5 16 32.1 321 2009 3 300 7652503410 1.5 24 35.6 357 2448 4 300 978
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREA RESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km
Kewberg Cables & Braids (Pty) Ltd.
16
It is used for transmission of analogue and
digital signals in process control systems. It
will be used for indoor and outdoor installa-
tion, in dry and wet locations, on racks, and
in conduits. Not allowed for direct connection
to low impedance source. It is recommended
for direct burial.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Triads—XLPE Insulated, Overall screened , Steel Wire armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XPLE) in-
sulated, cores twisted into triads. For triad cable the cores are black, white and red.
Each core is alpha numerically numbered. The cable is overall foil screened with a tinned copper drain wire.
The cable is supplied with a bedding sheath and is armoured with galvanised steel wire for protection. The
sheath can be flame retardant PVC, low halogen or halogen free compound in black or coloured on request.
Construction
Product CodeSize
(mm²)Triads
Nominal OD(mm)
Minimumbending ra-
dius (mm)
± Kg / KmCCG BW
Gland Size
Standarddrum length
(m)
Gross drumweight (Kg)
TRIADS
2503680 0.5 1 10.8 109 269 0 1000 344
2503700 0.5 4 16.7 168 557 1 1000 719
2503710 0.5 8 21.0 210 808 2 1000 954
2503720 0.5 12 24.8 248 1150 2 500 737
2503730 0.5 16 27.2 272 1371 3 500 930
2503745 0.5 24 33.7 337 2041 4 300 856
2503748 0.5 36 37.8 375 2499 4 300 994
2503750 1.0 1 11.7 117 316 0 1000 391
2503770 1.0 4 19.6 196 733 2 1000 820
2503780 1.0 8 24.3 245 1179 2 500 752
2503790 1.0 12 28.9 291 1565 3 500 1027
2503800 1.0 16 32.6 326 2086 3 300 788
2503810 1.5 1 12.6 126 358 0 1000 433
2503830 1.5 4 21.7 218 868 2 1000 1014
2503840 1.5 8 28.2 283 1505 3 500 997
2503850 1.5 12 34.0 340 2166 4 300 894
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREA RESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km
17
Kewberg Cables & Braids (Pty) Ltd.
17
It is used for transmission of analogue and
digital signals in process control systems. It will
be used for indoor and outdoor installation, in
dry and wet locations, on racks, and in con-
duits. Not allowed for direct connection to low
impedance source. It is recommended for di-
rect burial.
Remark: - Cables of sizes not listed above is available on request
Instrumentation Cables
Multi-Pairs—XLPE Insulated, Individual and Overall screened , Steel Wire armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insu-
lated. Cores twisted into pairs. Each pair is foil screened with it ’s own tin copper drain
wire. For paired cables the cores are black and white. Each core and all screens are alpha numerically num-
bered. The cable is overall foil screened with a tinned copper drain wire. The cable is supplied with a bedding
sheath and is armoured with galvanised steel wire armour for protection. The sheath can be flame retardant
PVC low halogen or halogen free compound in black or coloured on request.
Construction
Product CodeSize
(mm²)Pairs
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Grossdrum
weight(Kg)
PAIRS
2503430 0.5 2 14.6 146.0 439 0 1000 526
2503440 0.5 4 15.9 159.0 527 0 1000 614
2503450 0.5 8 19.6 197.0 761 2 1000 907
2503460 0.5 12 22.2 222.0 902 2 500 613
2503470 0.5 16 25.4 255.0 1267 2 500 878
2503480 0.5 24 29.3 293.0 1597 3 500 1043
2503485 0.5 32 33.3 334.0 2114 3 500 878
2503500 0.5 36 34.8 349.0 2268 4 300 924
2503520 1.0 2 16.0 161.0 517 3 1000 679
2503530 1.0 4 18.1 181.0 651 1 1000 797
2503540 1.0 8 21.4 215.0 934 2 1000 1080
2503550 1.0 12 26.2 262.0 1376 2 500 932
2503560 1.0 16 29.3 293.0 1644 3 500 1066
2503580 1.0 24 34.6 347.0 2356 4 300 951
2503350 1.5 2 18.0 180.0 620 1 1000 782
2503360 1.5 4 20.3 204.0 784 2 1000 930
2503370 1.5 8 25.7 257.0 1305 2 500 897
2503380 1.5 12 30.5 305.0 1863 3 500 1176
2503390 1.5 16 33.3 334.0 2228 4 300 912
2503410 1.5 24 39.8 339.0 2928 4 300 1170
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km
Kewberg Cables & Braids (Pty) Ltd.
18
It is used for transmission of analogue and
digital signals in process control systems. It will
be used for indoor and outdoor installation, in
dry and wet locations, on racks, and in con-
duits. Not allowed for direct connection to low
impedance source. It is recommended for di-
rect burial.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Triads—XLPE Insulated, Individual and Overall screened , Steel Wire armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insu-
lated. Cores twisted into triads. Each triad is foil screened with it ’s own tin copper drain
wire. For triad cables the cores are black, white and red. Each core and all screens are alpha numerically
numbered. The cable is overall foil screened with a tinned copper drain wire. The cable is supplied with a
bedding sheath and is armoured with galvanised steel wire armour for protection. The sheath can be flame
retardant PVC low halogen or halogen free compound in black or coloured on request.
Construction
Product CodeSize
(mm²)Triads
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Gross drumweight (Kg)
TRIADS
2503870 0.5 4 17.1 172.0 594 1 1000 669
2503880 0.5 8 21.5 215.0 870 2 1000 1016
2503900 0.5 12 25.8 259.0 1292 2 500 890
2503910 0.5 16 28.4 284.0 1526 3 500 1025
2503920 0.5 24 34.7 347.0 2231 4 300 914
2503925 0.5 36 39.7 394.0 2838 4 300 1143
2503940 1.0 4 20.0 200.0 777 2 1000 923
2503950 1.0 8 25.2 254.0 1301 2 500 894
2503960 1.0 12 30.5 306.0 1892 3 500 1190
2503970 1.0 16 33.5 336.0 2250 4 300 919
2504010 1.5 4 22.1 221.0 911 2 1000 1155
2504020 1.5 8 28.7 288.0 1586 3 500 1037
2504030 1.5 12 34.6 347.0 2288 4 300 930
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km
19
Kewberg Cables & Braids (Pty) Ltd.
19
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
The flame retardant sheath provides an excel-
lent water barrier and high chemical and abra-
sion resistant qualities.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Pairs—XLPE Insulated, Overall screened, APL / FR armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insu-
lated, cores twisted into pairs. For paired cable the cores are black and white. Each core is
alpha numerically numbered. The cable is overall foil screened with a tinned copper drain wire. The cable is
supplied with a bedding sheath and a flame retardant UV aluminium polyethylene laminate (APL/FR) for pro-
tection. A tinned copper wire is laid under the APL. The standard cable is black or coloured on request.
Construction
Product CodeSize
(mm²)Pairs
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Gross drumweight (Kg)
PAIRS2501810 0.5 1 9.4 85.0 90.0 0-20s 1000 1552501820 0.5 2 12.7 115.0 153.0 1-20 1000 2282501830 0.5 4 14.4 130.0 203.0 1-20 1000 2902501840 0.5 8 17.1 155.0 287.0 2-25 1000 4492501845 0.5 12 20.0 181.0 394.0 2-25 500 2842501850 0.5 16 21.7 195.0 471.0 3-32 500 3982501870 0.5 24 24.5 221.0 629.0 3-32 500 4772501880 0.5 36 29.4 265.0 772.0 4-40 300 429
2501900 1.0 1 10.2 92.0 111.0 0-20s 1000 1862501910 1.0 2 14.6 132.0 205.0 1-20 or 3-30 1000 2922501920 1.0 4 16.2 146.0 265.0 2-25 1000 4272501930 1.0 8 20.3 183.0 428.0 2-25 1000 5902501940 1.0 12 22.9 206.0 557.0 3-32 500 4412501950 1.0 16 25.3 228.0 706.0 3-32 500 4992501970 1.0 24 28.5 258.0 949.0 4-40 300 447
2501990 1.5 1 11.0 100.0 128.0 0-20s 1000 2032502000 1.5 2 16.2 146.0 248.0 2-25 1000 4102502010 1.5 4 18.4 166.0 354.0 2-25 1000 5002505020 1.5 8 22.8 206.0 535.0 3-32 500 4302502030 1.5 12 26.3 237.0 730.0 3-32 500 5112502040 1.5 16 29.4 265.0 943.0 4-40 300 4452502060 1.5 24 33.0 297.0 1256.0 4-40 300 539
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREA RESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km
Kewberg Cables & Braids (Pty) Ltd.
20
It is used for transmission of analogue and
digital signals in process control systems. It
will be used for indoor and outdoor installation,
in dry and wet locations, on racks, and in con-
duits. The FR sheath provides an excellent wa-
ter barrier and high chemical and abrasion re-
sistant qualities.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Triads—XLPE Insulated, Overall screened, APL / FR armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insu-
lated, cores twisted into triads. For triad cable the cores are black, white and red. Each
core is alpha numerically numbered. The cable is overall foil screened with a tinned copper drain wire. The ca-
ble is supplied with a bedding sheath and a flame retardant UV aluminium polyethylene laminate (APL/FR) for
protection. A tinned copper wire is laid under the APL. The standard cable is black or coloured on request.
Construction
Product CodeSize
(mm²)Triads
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Gross drumweight (Kg)
TRIADS
2502320 0.5 1 9.7 88.0 100.0 0-20s 1000 1652502340 0.5 4 15.6 141.0 244.0 2-25 1000 3312502350 0.5 8 19.8 179.0 392.0 2-25 1000 5382502360 0.5 12 23.0 207.0 512.0 3-32 500 4182502370 0.5 16 25.4 229.0 646.0 3-32 500 4692502374 0.5 24 31.1 280.0 919.0 4-40 300 4382502375 0.5 36 35.2 314.0 1217.0 5-50 300 609
2502380 1.0 1 10.5 95.0 126.0 0-20s 1000 2012502400 1.0 4 18.4 166.0 357.0 2-25 1000 5032502410 1.0 8 22.5 204.0 554.0 3-32 500 4392502420 1.0 12 26.7 242.0 773.0 4-40 500 5332502430 1.0 16 30.0 270.0 990.0 4-40 300 459
2502440 1.5 1 11.4 103.0 148.0 1-20 1000 2232502460 1.5 4 20.6 186.0 442.0 2-25 or 3-32 1000 5882502470 1.5 8 26.0 234.0 726.0 3-32 500 5092502480 1.5 12 31.4 283.0 1036.0 4-40 300 473
TECHNICAL INFORMATIONCONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREA RESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 90 pF/m 180 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 110 pF/m 220 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 120 pF/m 240 pF/m 0.65 mH/km
21
Kewberg Cables & Braids (Pty) Ltd.
21
It is used for transmission of analogue and
digital signals in process control systems. It will
be used for indoor and outdoor installation, in
dry and wet locations, on racks, and in con-
duits. The FR sheath provides an excellent wa-
ter barrier and high chemical and abrasion re-
sistant qualities.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Pairs—XLPE Insulated, Individual and Overall screened, APL / FR armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XPLE) in-
sulated. Cores twisted into pairs. Each pair is foil screened with it ’s own tin copper
drain wire. For paired cable the cores are black and white. Each core and all screens are alpha numerically
numbered. The cable is overall foil screened with tinned copper drain wire. The cable is supplied with a bed-
ding sheath and a flame retardant UV aluminium polyethylene laminate (APL/FR) for protection. A tin copper
drain wire is laid under the APL. The standard cable is black or coloured on requested.
Construction
Product CodeSize
(mm²)Pairs
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Grossdrum
weight(Kg)
Pairs2502070 0.5 2 13.4 121 177 1 1000 2642502080 0.5 4 14.8 133 234 2 1000 3212502090 0.5 8 18.5 167 378 2 1000 5242502100 0.5 12 20.7 187 465 3 500 3202502110 0.5 16 23.6 213 591 3 500 4582502130 0.5 24 27.1 244 781 4 500 5372502140 0.5 32 30.7 277 1016 4 500 7522502150 0.5 36 32.2 290 1070 4 300 498
2502160 1.0 2 14.9 135 224 2 1000 3112502170 1.0 4 16.5 149 297 2 1000 4592502180 1.0 8 20.9 189 496 3 1000 6422502190 1.0 12 24.4 220 682 3 500 5032502200 1.0 16 27.0 244 845 4 500 5692502220 1.0 24 32.0 289 1196 4 300 603
2502250 1.5 2 16.5 149 267 2 1000 4292502260 1.5 4 19.2 173 388 2 1000 5342502270 1.5 8 23.9 215 627 3 500 4762502280 1.5 12 27.5 248 839 4 500 6642502290 1.5 16 31.4 283 1099 4 300 4922502310 1.5 24 36.8 332 1534 5 300 704
TECHNICAL INFORMATIONCONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km
Kewberg Cables & Braids (Pty) Ltd.
22
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
The FR sheath provides an excellent water bar-
rier and high chemical and abrasion resistant
qualities.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Instrumentation Cables
Multi-Triads—XLPE Insulated, Individual and Overall screened, APL / FR armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XPLE) in-
sulated. Cores twisted into triads. Each triad is foil screened with it ’s own tin copper
drain wire. For triad cable the cores are black, white and red. Each core and all screens are alpha numerically
numbered. The cable is overall foil screened with tinned copper drain wire. The cable is supplied with a bed-
ding sheath and a flame retardant UV aluminium polyethylene laminate (APL/FR) for protection. A tin copper
drain wire is laid under the APL. The standard cable is black or coloured on requested.
Construction
Product CodeSize
(mm²)Triads
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Grossdrum
weight(Kg)
Triads2502500 0.5 4 16.0 144 271 2 1000 3582502510 0.5 8 20.4 184 444 2 1000 5902502520 0.5 12 24.0 217 614 3 500 4692502530 0.5 16 26.1 236 747 3 500 5202502540 0.5 24 32.0 289 1070 4 300 4832502551 0.5 36 36.7 328 1474 5 300 686
2502560 1.0 4 18.8 170 393 2 1000 5392502570 1.0 8 23.4 213 641 3 500 4832502580 1.0 12 27.5 248 868 4 500 6782502590 1.0 16 30.7 278 1126 4 300 500
2502610 1.5 4 21.0 189 472 3 1000 6182502620 1.5 8 26.5 239 787 3 500 5402502630 1.5 12 32.0 289 1126 4 300 500
TECHNICAL INFORMATION
CONDUCTOR CONDUCTOR VOLTAGE CAPACITANCE NOMINAL
AREARESISTANCE RATING MUTUAL GROUND INDUCTANCE
0.5mm2 39.00 Ω/km 150/250v 100 pF/m 200 pF/m 0.70 mH/km
1.0mm2 19.50 Ω/km 150/250v 120 pF/m 240 pF/m 0.63 mH/km
1.5mm2 13.30 Ω/km 150/250v 130 pF/m 260 pF/m 0.65 mH/km
Kewberg Cables & Braids (Pty) Ltd.
24
It is used for transmission of analogue and
digital signals in process control systems. It
will be used for indoor and outdoor installa-
tion, in dry and wet locations, on racks, and
in conduits. Not allowed for direct connection
to low impedance source, e.g. the public
mains electricity supply. It is not recom-
mended for direct burial.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.5mm2 39.00 Ω/km 300/500v
1.0mm2 19.50 Ω/km 600/1000v
1.5mm2 13.30 Ω/km 600/1000v
Product CodeSize
(mm²)Cores
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Gross drumweight (Kg)
300 / 500V
2500020 0.5 3 7.0 63 63 00 1000 112
2500030 0.5 4 7.8 70 77 00 1000 142
2500040 0.5 7 8.5 68 104 0 1000 183
2500050 0.5 12 10.9 87 160 0 1000 252
2500060 0.5 19 12.7 101 228 1 1000 347
2500070 0.5 24 15.1 120 305 2 500 235
0.5 27 15.9 127 336 2 500 248
600 / 1000V
2500100 1.0 3 7.8 71 86 00 1000 151
2500110 1.0 4 8.7 79 109 0 1000 353
2500140 1.0 7 10.6 96 172 0 1000 240
2500160 1.0 12 14.1 127 266 1 500 199
2500180 1.0 19 16.3 147 399 2 500 264
2500190 1.0 24 19.3 174 489 2 500 331
2500210 1.0 27 19.7 178 541 2 500 353
600 / 1000V
2500270 1.5 3 8.7 79 108 0 1000 173
2500280 1.5 4 10.1 91 145 0 1000 210
2500290 1.5 7 11.9 107 205 1 500 168
2500300 1.5 12 15.8 143 337 2 500 244
2500320 1.5 19 18.3 165 484 2 500 313
2500330 1.5 24 21.8 196 622 3 500 473
2500340 1.5 27 22.3 201 681 3 500 503
Control Cables
Multi-cores—XLPE Insulated, Overall screened , Unarmoured
E&OE
Applications & features
Electrical Data
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insulated, overall foil
screened with tinned copper drain wire . Colour coded cores up to 4 core , Thereafter white numbered cores
identified by black alpha numerical marking . Sheath can be flame retardant PVC low halogen or halogen free
compound in black or coloured on request .
Construction
25
Kewberg Cables & Braids (Pty) Ltd.
25
It is used for transmission of analogue and
digital signals in process control systems. It
will be used for indoor and outdoor installa-
tion, in dry and wet locations, on racks, and
in conduits. Not allowed for direct connection
to low impedance source, e.g. the public
mains electricity supply. It is recommended
for direct burial.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.5mm2 39.00 Ω/km 300/500v
1.0mm2 19.50 Ω/km 600/1000v
1.5mm2 13.30 Ω/km 600/1000v
Control Cables
Multi-cores—XLPE Insulated, Overall screened , Steel Wire armoured
E&OE
Applications & features
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insulated, overall foil
screened with tinned copper drain wire . Colour coded cores up to 4 core , Thereafter white numbered
cores identified by black alpha numerical marking . Cables supplied with a bedding sheath and galvanised
steel wire armour for protection. Sheath can be flame retardant PVC low halogen or halogen free compound
in black or coloured on request .
Construction
Product codeSize
(mm²)Cores
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Gross drumweight (Kg)
2502670 0.5 3 11.9 120 318 0 1000 393
2502680 0.5 4 12.7 127 346 0 1000 421
2502710 0.5 7 14.4 144 438 0 1000 946
2502740 0.5 12 17.0 170 572 1 1000 734
2502760 0.5 19 19.6 197 749 2 1000 895
2502770 0.5 24 21.9 219 873 2 1000 599
2502790 0.5 27 22.2 223 912 2 500 618
2502840 1.0 3 12.7 128 366 0 1000 441
2502850 1.0 4 13.6 136 409 0 1000 496
2502880 1.0 7 15.5 156 521 0 1000 608
2502900 1.0 12 19.4 194 744 2 500 534
2502920 1.0 19 21.6 216 921 2 500 623
2502930 1.0 24 25.3 254 1 280 2 500 884
2502950 1.0 27 25.7 258 1 343 2 500 916
2503000 1.5 3 13.6 137 414 0 1000 501
2503010 1.5 4 15.0 150 482 0 1000 569
2503020 1.5 7 16.8 168 601 1 500 376
2503030 1.5 12 21.1 211 869 2 500 597
2503050 1.5 19 24.3 244 1 256 2 500 790
2503060 1.5 24 27.8 278 1 522 3 500 1005
2503070 1.5 27 28.7 287 1 617 3 500 1053
Electrical Data
Kewberg Cables & Braids (Pty) Ltd.
26
It is used for transmission of analogue and
digital signals in process control systems. It
will be used for indoor and outdoor installa-
tion, in dry and wet locations, on racks, and
in conduits. Not allowed for direct connection
to low impedance source, e.g. the public
mains electricity supply. It is not recom-
mended for direct burial.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.5mm2 39.00 Ω/km 300/500v
1.0mm2 19.50 Ω/km 600/1000v
1.5mm2 13.30 Ω/km 600/1000v
Control Cables
Multi-cores—XLPE Insulated, Overall screened , APL / FR armoured
E&OE
Applications & features
Electrical Data
Plain annealed multi-stranded copper conductor, cross-linked polyethylene (XLPE) insulated, overall foil
screened with tinned copper drain wire . Colour coded cores up to 4 core , Thereafter white numbered cores
identified by black alpha numerical marking . Cable supplied with a bedding sheath and a UV flame retardant
aluminium polyethylene laminate (APL/FR) for protection . A tin copper drain wire is laid under the APL.
Standard cable is black and coloured cable can be supplied on request .
Construction
Product CodeSize
(mm²)Cores
Nominal OD(mm)
Minimumbending ra-dius (mm)
± Kg / Km Gland SizeStandard
drum length(m)
Grossdrum
weight(Kg)
2501370 0.5 4 11.5 104 136 1 1000 211
2501400 0.5 7 13.2 120 185 1 1000 272
2501430 0.5 12 15.8 143 259 2 1000 346
2501450 0.5 19 18.5 167 366 2 1000 512
2501460 0.5 24 20.8 187 436 3 500 305
2501480 0.5 27 21.1 190 464 3 500 394
2501540 1.0 3 11.6 105 145 1 1000 220
2501550 1.0 4 12.5 113 169 1 1000 244
2501580 1.0 7 14.4 130 239 1 1000 326
2501600 1.0 12 18.3 165 370 2 500 256
2501620 1.0 19 20.5 185 494 3 500 334
2501630 1.0 24 23.5 212 619 3 500 472
2501650 1.0 27 23.9 216 665 3 500 495
2501710 1.5 3 12.5 113 179 1 1000 254
2501720 1.5 4 13.9 125 217 1 1000 304
2501730 1.5 7 15.6 141 284 2 500 217
2501740 1.5 12 20.0 180 449 2 500 312
2501760 1.5 19 22.5 203 611 3 500 468
2501770 1.5 24 26.0 234 769 3 500 531
2501780 1.5 27 26.4 238 829 3 902 561
27
Kewberg Cables & Braids (Pty) Ltd.
27
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Control Cables
Multi– Cores —Unscreened - 300/500v
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed .
2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereaf-
ter black numbered cores with a green/yellow earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREARESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v
1.5mm2 12.10 300/500v
Product Code Size (mm²) Cores Nominal OD (mm) Packing (m) Gland Size
2000580 0.75 2 4.7 1000 00
2000590 0.75 3 5.1 1000 00
2000600 0.75 4 5.7 1000 00
2000610 0.75 5 6.3 1000 00
2000620 0.75 6 7.0 1000 0
2000630 0.75 7 7.1 1000 0
2000640 0.75 8 7.8 1000 0
2000650 0.75 10 9.4 1000 0
2000660 0.75 12 9.8 1000 0
2000670 0.75 14 10.3 500 0
2000680 0.75 16 11.1 500 1
2000690 0.75 18 11.8 500 1
2000700 0.75 19 11.8 500 1
2000710 0.75 20 12.5 500 1
2000720 0.75 21 13.0 500 1
2000730 0.75 24 14.1 500 1
2000740 0.75 25 14.1 500 1
2000750 0.75 27 14.5 500 2
2000760 0.75 30 15.8 500 2
2000770 0.75 32 15.9 500 2
2000780 0.75 34 16.4 500 2
2000790 0.75 36 16.5 500 2
2000800 0.75 37 16.5 500 2
2000810 0.75 40 17.7 500 2
2000820 0.75 42 17.7 500 2
2000830 0.75 50 19.8 500 2
2000840 0.75 61 21.2 500 3
Kewberg Cables & Braids (Pty) Ltd.
28
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Control Cables
Multi– Cores —Unscreened - 300/500v
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed . 2,3 and 4 cores are
colour coded (blue, brown , green/yellow and black ) thereafter blablack numbered cores with a green/
yellow earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v
1.5mm2 12.10 300/500v
Product Code Size (mm²)Cores
Nominal OD(mm)
Packing (m) Gland Size
2000850 1.00 2 5.0 1000 00
2000860 1.00 3 5.4 1000 00
2000870 1.00 4 6.0 1000 00
2000880 1.00 5 6.7 1000 00
2000890 1.00 6 7.5 1000 0
2000900 1.00 7 7.5 1000 0
2000910 1.00 8 8.3 1000 0
2000920 1.00 10 10.0 1000 0
2000930 1.00 12 10.4 1000 0
2000940 1.00 14 11.0 500 1
2000950 1.00 16 11.7 500 1
2000960 1.00 18 12.5 500 1
2000970 1.00 19 12.5 500 1
2000980 1.00 20 13.3 500 1
2000990 1.00 21 13.8 500 1
2001000 1.00 22 13.8 500 1
2001010 1.00 24 15.0 500 2
2001020 1.00 25 15.0 500 2
2001030 1.00 27 15.4 500 2
2001040 1.00 30 16.0 500 2
2001050 1.00 32 16.7 500 2
2001060 1.00 34 17.5 500 2
2001070 1.00 36 17.8 500 2
2001080 1.00 37 17.8 500 2
2001090 1.00 40 18.8 500 2
2001100 1.00 42 18.8 500 2
2001110 1.00 50 21.0 500 3
2001120 1.00 61 22.5 500 3
2001130 1.00 65 23.8 500 3
29
Kewberg Cables & Braids (Pty) Ltd.
29
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Control Cables
Multi– Cores —Unscreened - 300/500v
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed .
2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereaf-
ter black numbered cores with a green/yellow earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREARESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v
1.5mm2 12.10 300/500v
Product Code Size (mm²)Cores
Nominal OD(mm)
Packing (m) Gland Size
2001140 1.50 2 5.9 1000 00
2001150 1.50 3 6.4 1000 00
2001160 1.50 4 7.1 1000 0
2001170 1.50 5 7.9 1000 0
2001180 1.50 6 8.8 1000 0
2001190 1.50 7 8.8 1000 0
2001200 1.50 8 9.8 1000 0
2001210 1.50 10 11.8 1000 1
2001220 1.50 12 12.2 1000 1
2001230 1.50 14 13.0 500 1
2001240 1.50 16 13.8 500 1
2001250 1.50 18 14.7 500 2
2001260 1.50 19 14.7 500 2
2001270 1.50 20 15.7 500 2
2001280 1.50 21 16.3 500 2
2001290 1.50 24 17.7 500 2
2001300 1.50 25 17.7 500 2
2001310 1.50 27 18.1 500 2
2001320 1.50 30 18.9 500 2
2001330 1.50 32 19.7 500 2
2001340 1.50 34 20.6 500 3
2001350 1.50 36 20.8 500 3
2001360 1.50 37 20.8 500 3
2001370 1.50 40 22.2 500 3
2001390 1.50 50 24.8 500 3
2001400 1.50 60 26.5 500 3
Kewberg Cables & Braids (Pty) Ltd.
30
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Control Cables
Multi– Cores —Unscreened - 600/1000v
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed . 2,3 and 4 cores are
colour coded (blue, brown , green/yellow and black ) thereafter black numbered cores with a green/yellow
earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREARESISTANCE RATING
1.0mm2 18.10 600/1000V
1.5mm2 12.10 600/1000V
2.5mm2 7.41 600/1000V4.0mm2 4.61 600/1000V6.0mm2 3.08 600/1000V
10.0mm2 1.83 600/1000V16.0mm2 1.15 600/1000V
Product Code Size (mm²)Cores
Nominal OD(mm)
Packing (m) Gland Size
1.00 2 7.2 1000 00
1.00 3 7.6 1000 00
1.00 4 8.3 1000 0
1.00 6 10.0 1000 0
1.00 7 10.9 1000 0
1.00 8 13.20 1000 1
1.00 12 13.60 1000 2
1.00 16 15.10 500 2
1.00 20 17.90 500 2
1.00 30 20.70 500 2
1.00 50 26.50 500 3
1.50 2 8.0 1000 00
1.50 3 8.5 1000 0
1.50 4 9.3 1000 0
1.50 6 11.6 1000 1
1.50 7 11.6 1000 1
1.50 12 15.3 1000 2
1.50 14 16.1 500 2
1.50 19 18.4 500 2
1.50 20 19.4 500 2
1.50 24 21.6 500 3
1.50 25 21.6 500 3
1.50 27 22.1 500 3
31
Kewberg Cables & Braids (Pty) Ltd.
31
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Control Cables
Multi– Cores —Unscreened - 600/1000v
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed . 2,3 and 4 cores are
colour coded (blue, brown , green/yellow and black ) thereafter black numbered cores with a green/yellow
earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREARESISTANCE RATING
1.0mm2 18.10 600/1000V
1.5mm2 12.10 600/1000V
2.5mm2 7.41 600/1000V4.0mm2 4.61 600/1000V6.0mm2 3.08 600/1000V
10.0mm2 1.83 600/1000V16.0mm2 1.15 600/1000V
Product Code Size (mm²)Cores
Nominal OD (mm) Packing (m) Gland Size
2001410 2.50 2 8.8 1000 0
2001420 2.50 3 9.3 1000 0
2001430 2.50 4 10.6 1000 0
2001440 2.50 5 11.7 1000 1
2001450 2.50 6 12.8 1000 1
2001460 2.50 7 12.8 1000 1
2001470 2.50 8 13.9 1000 1
2001490 2.50 10 16.4 1000 2
2001500 2.50 12 16.9 1000 2
2001510 2.50 14 18.3 500 2
2001520 2.50 16 19.3 500 2
2001530 2.50 18 20.4 500 2
2001540 2.50 19 20.4 500 2
2001550 2.50 20 21.5 500 3
2001560 2.50 21 22.3 500 3
2001570 2.50 24 24.4 500 3
2001580 2.50 25 24.4 500 3
2001590 2.50 27 24.9 500 3
2001600 2.50 30 25.8 500 3
2001610 2.50 32 26.9 500 4
2001620 2.50 34 28.2 500 4
2001630 2.50 36 28.2 500 4
2001640 2.50 37 28.2 500 4
2001650 2.50 50 33.2 500 4
Kewberg Cables & Braids (Pty) Ltd.
32
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Control Cables
Multi– Cores —Unscreened - 600/1000v
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , PVC sheathed . 2,3 and 4 cores are
colour coded (blue, brown , green/yellow and black ) thereafter black numbered cores with a green/yellow
earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREARESISTANCE RATING
1.0mm2 18.10 600/1000V
1.5mm2 12.10 600/1000V
2.5mm2 7.41 600/1000V4.0mm2 4.61 600/1000V6.0mm2 3.08 600/1000V
10.0mm2 1.83 600/1000V16.0mm2 1.15 600/1000V
Product Code Size (mm²)
Cores
Nominal OD (mm) Packing (m) Gland Size
2001660 4.00 2 10.8 500 0
2001670 4.00 3 11.5 500 1
2001680 4.00 4 13.1 500 1
2001690 4.00 5 14.4 500 1
2001700 4.00 6 15.8 500 2
2001710 4.00 7 15.8 500 2
2001720 4.00 12 21.5 500 3
2001730 4.00 19 25.8 500 3
2001740 6.00 2 12.2 500 1
2001750 6.00 3 13.0 500 1
2001760 6.00 4 14.7 500 2
2001770 6.00 5 16.1 500 2
2001780 6.00 6 17.7 500 2
2001790 6.00 7 17.7 500 2
2001800 10.00 2 14.8 500 2
2001810 10.00 3 15.8 500 2
2001820 10.00 4 17.3 500 2
2001830 10.00 5 19.1 500 2
2001840 10.00 6 21.0 500 3
2001800 10.00 7 21.0 500 3
2001860 16.00 3 18.3 500 2
2001870 16.00 4 20.1 500 2
33
Kewberg Cables & Braids (Pty) Ltd.
33
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
These cables are used in machinery, machine
tools, system and appliance engineering,
measuring, control, heating and air conditioning
technologies.
Control Cables
Multi– Cores — Copper Braid screened
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , copper wire braid screened , PVC
sheathed . 2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereafter black
numbered cores with a green/yellow earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v
1.5mm2 12.10 300/500v
2.5mm2 7.41 600/1000V
4.0mm2 4.61 600/1000V
Product CodeSize
(mm²) CoresNominal OD
(mm)Packing (m) Gland Size
2002870 0.75 2 7.1 1000 0
2002880 0.75 3 7.5 1000 0
2002890 0.75 4 8.1 1000 0
2002900 0.75 5 8.8 1000 0
2002910 0.75 6 9.8 1000 0
2002920 0.75 7 9.8 1000 0
2002930 0.75 8 10.6 1000 0
2002940 0.75 10 12.2 1000 1
2002950 0.75 12 12.5 1000 1
2002960 0.75 14 13.2 500 1
2002970 0.75 16 13.8 500 1
2002980 0.75 18 14.9 500 2
2002990 0.75 19 14.9 500 2
2003000 0.75 20 15.7 500 2
2003010 0.75 21 16.2 500 2
2003020 0.75 24 17.3 500 2
2003030 0.75 25 17.3 500 2
2003040 0.75 27 17.6 500 2
2003050 0.75 30 18.2 500 2
2003060 0.75 32 18.9 500 2
2003070 0.75 34 19.6 500 2
2003080 0.75 36 19.6 500 2
2003090 0.75 37 19.8 500 2
2003100 0.75 40 20.9 500 3
2003110 0.75 42 20.9 500 3
2003120 0.75 50 23.4 500 3
Kewberg Cables & Braids (Pty) Ltd.
34
Control Cables
Multi– Cores — Copper Braid screened
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , copper wire braid screened , PVC
sheathed . 2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereafter black
numbered cores with a green/yellow earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v
1.5mm2 12.10 300/500v
2.5mm2 7.41 600/1000V
4.0mm2 4.61 600/1000V
Product CodeSize
(mm²) CoresNominal OD
(mm)Packing (m) Gland Size
2003130 1.00 2 7.4 1000 0
2003140 1.00 3 7.8 1000 0
2003150 1.00 4 8.4 1000 0
2003160 1.00 5 9.2 1000 0
2003170 1.00 6 10.3 1000 0
2003180 1.00 7 10.3 1000 0
2003190 1.00 8 11.1 1000 1
2003200 1.00 10 12.8 1000 1
2003210 1.00 12 13.2 1000 1
2003220 1.00 14 13.8 500 1
2003230 1.00 16 14.6 500 2
2003240 1.00 18 15.7 500 2
2003250 1.00 19 15.7 500 2
2003260 1.00 20 16.5 500 2
2003270 1.00 21 17.1 500 2
2003280 1.00 24 18.2 500 2
2003290 1.00 25 18.2 500 2
2003300 1.00 27 18.6 500 2
2003310 1.00 30 19.2 500 2
2003320 1.00 32 20.0 500 2
2003330 1.00 34 20.7 500 3
2003340 1.00 36 20.7 500 3
2003350 1.00 37 20.7 500 3
2003360 1.00 40 22.1 500 3
2003370 1.00 42 22.1 500 3
2003380 1.00 50 24.6 500 3
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
These cables are used in machinery, machine
tools, system and appliance engineering,
measuring, control, heating and air conditioning
technologies.
35
Kewberg Cables & Braids (Pty) Ltd.
35
Control Cables
Multi– Cores — Copper Braid screened
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , copper wire braid screened , PVC
sheathed . 2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereafter black
numbered cores with a green/yellow earth conductor .
Construction
Product CodeSize
(mm²) CoresNominal OD
(mm)Packing (m) Gland Size
2003400 1.50 2 8.8 1000 0
2003410 1.50 3 9.3 1000 0
2003420 1.50 4 10.5 1000 0
2003430 1.50 5 11.4 1000 1
2003440 1.50 6 12.4 1000 1
2003450 1.50 7 12.4 1000 1
2003460 1.50 8 15.6 1000 2
2003470 1.50 10 15.6 1000 2
2003480 1.50 12 16.1 1000 2
2003490 1.50 14 16.9 500 2
2003500 1.50 16 18.2 500 2
2003510 1.50 18 19.2 500 2
2003520 1.50 19 19.2 500 2
2003530 1.50 20 20.3 500 2
2003540 1.50 21 20.9 500 3
2003550 1.50 24 22.4 500 3
2003560 1.50 25 22.4 500 3
2003570 1.50 27 22.9 500 3
2003580 1.50 30 23.7 500 3
2003590 1.50 32 24.6 500 3
2003600 1.50 34 25.6 500 3
2003610 1.50 36 25.6 500 3
2003620 1.50 37 25.6 500 3
2003630 1.50 40 27.3 500 4
2003640 1.50 42 27.3 500 4
2003650 1.50 50 30.5 500 4
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v
1.5mm2 12.10 300/500v
2.5mm2 7.41 600/1000V
4.0mm2 4.61 600/1000V
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
These cables are used in machinery, machine
tools, system and appliance engineering,
measuring, control, heating and air conditioning
technologies.
Kewberg Cables & Braids (Pty) Ltd.
36
Control Cables
Multi– Cores — Copper Braid screened
E&OE
Applications & features
Plain flexible stranded annealed copper conductor, PVC insulated , copper wire braid screened , PVC
sheathed . 2,3 and 4 cores are colour coded (blue, brown , green/yellow and black ) thereafter black
numbered cores with a green/yellow earth conductor .
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v
1.5mm2 12.10 300/500v
2.5mm2 7.41 600/1000V
4.0mm2 4.61 600/1000V
Product CodeSize
(mm²) Cores
Nominal OD(mm)
Packing (m) Gland Size
2003660 2.50 2 10.00 1000 0
2003670 2.50 3 10.60 1000 0
2003680 2.50 4 11.50 1000 1
2003690 2.50 5 12.90 1000 1
2003700 2.50 6 14.00 1000 1
2003710 2.50 7 14.00 1000 1
2003720 2.50 8 15.20 1000 2
2003730 2.50 10 17.60 1000 2
2003740 2.50 12 18.20 1000 2
2003750 2.50 14 19.10 500 2
2003760 2.50 16 20.10 500 2
2003770 2.50 18 21.20 500 3
2003780 2.50 19 21.20 500 3
2003790 2.50 20 22.40 500 3
2003800 2.50 21 23.50 500 3
2003810 2.50 24 25.20 500 3
2003820 2.50 25 25.20 500 3
2003830 2.50 27 25.80 500 3
2003840 2.50 30 26.70 500 4
2003850 2.50 32 27.70 500 4
2003860 2.50 34 28.80 500 4
2003870 2.50 36 28.80 500 4
2003880 2.50 37 28.80 500 4
2003890 2.50 40 30.70 500 4
2003900 2.50 42 30.70 500 4
2003910 2.50 50 34.30 500 4
2003920 4.00 2 12.40 500 1
2003930 4.00 3 13.10 500 12003940 4.00 4 13.90 500 1
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
These cables are used in machinery, machine
tools, system and appliance engineering,
measuring, control, heating and air conditioning
technologies.
37
Kewberg Cables & Braids (Pty) Ltd.
37
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Control Cables
Multi– Cores — Galvanised Steel Wire Braid screened
E&OE
Applications & features
Construction
CONDUCTOR CONDUCTOR VOLTAGEAREA RESISTANCE RATING
0.5mm2 39 300/500v0.75mm2 24.50 300/500v1.0mm2 18.10 300/500v1.5mm2 12.10 300/500v2.5mm2 7.41 600/1000v4.0mm2 4.61 600/1000v6.0mm2 3.08 600/1000v
10.0mm2 1.83 600/1000v16.0mm2 1.15 600/1000v
Product Code Size (mm²) CoresNominal OD
(mm)Packing (m) Gland Size
2900010 0.50 2 8.10 1000 0
2900060 0.50 3 8.60 1000 0
2900070 0.50 4 9.60 1000 0
2900080 0.50 5 10.00 1000 0
2900090 0.50 7 11.10 1000 0
2900030 0.50 12 11.20 1000 1
2900040 0.50 14 13.80 500 1
2900050 0.50 20 15.70 500 2
2900120 0.75 2 9.10 1000 0
2900150 0.75 3 9.50 1000 0
2900170 0.75 4 10.10 1000 0
2900190 0.75 5 10.80 1000 0
2900220 0.75 7 11.80 1000 1
2900100 0.75 12 14.50 1000 1
2900110 0.75 20 18.10 500 2
2900140 0.75 34 22.00 500 3
2900210 0.75 61 29.00 500 4
2900310 1.00 2 9.40 1000 0
2900360 1.00 3 9.80 1000 0
2900400 1.00 4 10.40 1000 0
2900430 1.00 5 11.20 1000 1
2900450 1.00 7 12.30 1000 1
2900230 1.00 10 14.80 1000 2
2900250 1.00 12 15.20 1000 2
2900260 1.00 14 16.20 500 2
2900270 1.00 19 18.10 500 2
2900280 1.00 20 18.90 500 2
2900290 1.00 25 20.60 500 2
2900380 1.00 40 24.50 500 22900420 1.00 50 27.00 500 3
Plain flexible stranded annealed copper conductor, PVC insulated , PVC bedded, Galvanised steel wire
Braid, PVC sheathed. 2,3 and 4 cores are colour coded (blue, brown, green/yellow and black ) thereafter
black numbered cores with a green/yellow earth conductor . Various sheathing grades and colours avail-
able
Plain flexible stranded annealed copper conductor, PVC insulated , PVC bedded, Galvanised steel wire
Braid, PVC sheathed. 2,3 and 4 cores are colour coded (blue, brown, green/yellow and black ) thereafter
black numbered cores with a green/yellow earth conductor . Various sheathing grades and colours avail-
able
Kewberg Cables & Braids (Pty) Ltd.
38
It is used for transmission of analogue and digi-
tal signals in process control systems. It will be
used for indoor and outdoor installation, in dry
and wet locations, on racks, and in conduits.
Not allowed for direct connection to low imped-
ance source, e.g. the public mains electricity
supply. It is not recommended for direct burial.
Control Cables
Multi– Cores — Galvanised Steel Wire Braid screened
E&OE
Applications & features
Construction
CONDUCTOR CONDUCTOR VOLTAGEAREA RESISTANCE RATING
0.5mm2 39 300/500v0.75mm2 24.50 300/500v1.0mm2 18.10 300/500v1.5mm2 12.10 300/500v2.5mm2 7.41 600/1000v4.0mm2 4.61 600/1000v6.0mm2 3.08 600/1000v10.0mm2 1.83 600/1000v16.0mm2 1.15 600/1000v
Product Code Size (mm²) CoresNominal OD
(mm)Packing (m) Gland Size
2900530 1.50 2 10.80 1000 02900560 1.50 3 11.30 1000 12900600 1.50 4 12.50 1000 12900630 1.50 5 13.40 1000 12900660 1.50 7 14.40 1000 12900480 1.50 12 18.10 1000 22900500 1.50 14 19.30 500 22900510 1.50 19 21.60 500 3
2900750 2.50 2 12.40 1000 12900760 2.50 3 13.00 1000 12900770 2.50 4 13.90 1000 12900780 2.50 5 15.30 1000 22900800 2.50 7 16.40 500 22900730 2.50 12 21.00 500 32900740 2.50 19 24.00 500 3
2900820 4.00 2 15.20 500 22900830 4.00 3 15.90 500 22900850 4.00 4 16.70 500 22900860 4.00 7 19.50 2
2900870 6.00 4 18.60 500 22900890 6.00 7 21.50 500 3
2900690 10.00 4 21.40 500 3
2900710 16.00 4 24.20 500 3
39
Kewberg Cables & Braids (Pty) Ltd.
39
These multicore flexible cables are designed
for high density wiring between components
and within instruments and electronic equip-
ment. They are extensively used in aircraft,
process control systems, computers, data
processors, military vehicles and military
equipment
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Defence Specification
Cables
Paired Cables—Overall Screened - Defence Standard 61/12
E&OE
Applications & features
Tinned stranded annealed copper conductor, PVC insulated (150/250v), aluminium / Mylar foil screened,
tinned stranded copper drain wire, PVC sheathed (grey)
Construction
CONDUCTOR CONDUCTOR VOLTAGE
RESISTANCE RATING
0.22mm2 92.4 Ω/km 150/250v
0.50mm2 40.1 Ω/km 150/250v
Product CodeSize
(mm²)Pairs
Nominal OD(mm)
± Kg / Km Packing (m) Core Identification Gland Size
2003950 0.22 1 3.6 27 1000 DEF STAN 61-12 00
2003960 0.22 2 6.2 51 1000 DEF STAN 61-12 00
2003970 0.22 3 6.5 62 1000 DEF STAN 61-12 00
2003980 0.22 4 7.2 76 1000 DEF STAN 61-12 00
2004000 0.22 6 8.1 108 1000 DEF STAN 61-12 00
2004020 0.22 8 9.2 122 1000 DEF STAN 61-12 0
2004050 0.22 12 11.6 179 1000 DEF STAN 61-12 1
2004110 0.22 18 13.4 242 500 DEF STAN 61-12 1
2004140 0.22 25 15.4 323 500 DEF STAN 61-12 2
2004150 0.22 30 16.4 355 500 DEF STAN 61-12 2
2004160 0.22 36 18.3 408 500 DEF STAN 61-12 2
2004165 0.22 50 20.3 518 500 DEF STAN 61-12 2
2004170 0.50 1 5.1 56 1000 DEF STAN 61-12 00
2004180 0.50 2 7.6 76 1000 DEF STAN 61-12 00
2004190 0.50 3 8.1 105 1000 DEF STAN 61-12 00
2004200 0.50 4 8.6 119 1000 DEF STAN 61-12 0
2004220 0.50 6 11.2 160 1000 DEF STAN 61-12 0
2004240 0.50 8 12.2 205 1000 DEF STAN 61-12 1
2004270 0.50 12 15.2 271 1000 DEF STAN 61-12 2
2004330 0.50 18 18.8 381 500 DEF STAN 61-12 2
2004340 0.50 20 21.3 418 500 DEF STAN 61-12 32004360 0.50 25 22.3 497 500 DEF STAN 61-12 3
Electrical Data
Kewberg Cables & Braids (Pty) Ltd.
40
These multicore flexible cables are designed
for high density wiring between components
and within instruments and electronic equip-
ment. They are extensively used in aircraft,
process control systems, computers, data
processors, military vehicles and military
equipment
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Paired Cables—Individual and Overall Screened - Defence Standard 61/12
E&OE
Applications & features
Electrical Data
Construction
Tinned stranded annealed copper conductor, PVC insulated (150/250v), aluminium / Mylar foil screened,
tinned stranded copper drain wire, PVC sheathed (grey)
Defence Specification
Cables
CONDUCTOR CONDUCTOR VOLTAGE
RESISTANCE RATING
0.22mm2 92.4 Ω/km 150/250v
0.50mm2 40.1 Ω/km 150/250v
ProductCode
Size(mm²)
PairsNominal OD
(mm)± Kg / Km
Packing(m)
Core Identification Gland Size
2004395 0.22 2 6.3 63 1000 DEF STAN 61-12 00
2004400 0.22 3 7.1 77 1000 DEF STAN 61-12 00
2004410 0.22 4 7.5 95 1000 DEF STAN 61-12 0
2004430 0.22 6 8.8 135 1000 DEF STAN 61-12 0
2004450 0.22 8 9.7 153 1000 DEF STAN 61-12 0
2004470 0.22 12 11.6 223 1000 DEF STAN 61-12 1
0
2004560 0.50 2 8.8 95 1000 DEF STAN 61-12 0
2004570 0.50 3 10.0 131 1000 DEF STAN 61-12 0
2004580 0.50 4 10.8 148 1000 DEF STAN 61-12 0
2004600 0.50 6 13.2 200 1000 DEF STAN 61-12 0
2004610 0.50 8 14.7 256 1000 DEF STAN 61-12 2
2004630 0.50 12 17.8 339 1000 DEF STAN 61-12 2
41
Kewberg Cables & Braids (Pty) Ltd.
41
These multicore flexible cables are designed
for high density wiring between components
and within instruments and electronic equip-
ment. They are extensively used in aircraft,
process control systems, computers, data
processors, military vehicles and military
equipment
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Defence Specification
Cables
Multi Cores—Tinned copper Braid Overall Screened - Defence Standard 61/12
E&OE
Applications & features
Tinned stranded annealed copper conductor, PVC insulated (150/250v), clear polyester taped, tinned copper
wire braid screened, PVC sheathed (grey)
Construction
CONDUCTOR CONDUCTOR VOLTAGE
RESISTANCE RATING
0.22mm2 92.4 Ω/km 150/250v
0.50mm2 40.1 Ω/km 150/250v
Electrical Data
ProductCode
Size(mm²) Cores
Nominal OD(mm)
± Kg / KmPacking
(m)Core Identification Gland Size
2002330 0.22 2 4.1 30 1000 DEF STAN 61-12 00
2002340 0.22 3 4.6 36 1000 DEF STAN 61-12 00
2002350 0.22 4 4.9 40 1000 DEF STAN 61-12 00
2002380 0.22 7 6.1 63 1000 DEF STAN 61-12 00
2002390 0.22 8 6.4 81 1000 DEF STAN 61-12 00
2002400 0.22 10 7.1 86 1000 DEF STAN 61-12 00
2002410 0.22 12 7.3 88 1000 DEF STAN 61-12 00
2002440 0.22 18 8.6 138 1000 DEF STAN 61-12 0
2002460 0.22 20 9.1 146 1000 DEF STAN 61-12 0
2002490 0.22 25 9.6 166 1000 DEF STAN 61-12 0
2002600 0.50 2 6.1 53 1000 DEF STAN 61-12 00
2002610 0.50 3 6.6 64 1000 DEF STAN 61-12 00
2002620 0.50 4 7.6 78 1000 DEF STAN 61-12 00
2002640 0.50 6 8.6 91 1000 DEF STAN 61-12 0
2002650 0.50 7 9.1 108 1000 DEF STAN 61-12 0
2002660 0.50 8 10.2 130 1000 DEF STAN 61-12 0
2002680 0.50 12 11.2 171 1000 DEF STAN 61-12 0
2002700 0.50 16 12.2 200 1000 DEF STAN 61-12 0
2002710 0.50 18 12.7 230 1000 DEF STAN 61-12 0
2002730 0.50 20 13.7 266 1000 DEF STAN 61-12 0
2002760 0.50 25 15.2 339 1000 DEF STAN 61-12 2
2002780 0.50 30 16.2 383 1000 DEF STAN 61-12 2
2002790 0.50 36 18.3 447 500 DEF STAN 61-12 2
Kewberg Cables & Braids (Pty) Ltd.
42
These flexible cables are designed for high
density wiring between components and
within instruments and electronic equipment.
They are extensively used in aircraft, process
control systems, computers, data proces-
sors, military vehicles and military equipment
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Multi Pairs—Tinned copper Braid Overall Screened - Defence Standard 61/12
E&OE
Applications & features
Electrical Data
Construction
Tinned stranded annealed copper conductor, PVC insulated (150/250v), clear polyester taped, tinned copper
wire braid screened, PVC sheathed (grey)
Defence Specification
Cables
CONDUCTOR CONDUCTOR VOLTAGE
RESISTANCE RATING
0.22mm2 92.4 Ω/km 150/250v
0.50mm2 40.1 Ω/km 150/250v
ProductReference
Size(mm²) Pairs
Nominal OD(mm)
± Kg / KmPacking
(m)Core Identification Gland Size
2002325 0.22 1 4.1 30 1000 DEF STAN 61-12 00
2002335 0.22 2 6.2 42 1000 DEF STAN 61-12 00
2002345 0.22 3 6.5 64 1000 DEF STAN 61-12 00
2002355 0.22 4 7.1 85 1000 DEF STAN 61-12 00
2002375 0.22 6 8.1 101 1000 DEF STAN 61-12 00
2002395 0.22 8 9.3 126 1000 DEF STAN 61-12 0
43
Kewberg Cables & Braids (Pty) Ltd.
43
These flexible cables are designed for high
density wiring between components and
within instruments and electronic equipment.
They are extensively used in aircraft, process
control systems, computers, data proces-
sors, military vehicles and military equipment
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Defence Specification
Cables
Multi Cores—Tinned Overall Foil Screened - Defence Standard 61/12
E&OE
Applications & features
Tinned stranded annealed copper conductor, PVC insulated (150/250V), overall foil
screened with tin copper drain wire, PVC sheathed (grey).Construction
CONDUCTOR CONDUCTOR VOLTAGE
RESISTANCE RATING
0.22mm2 92.4 Ω/km 150/250v
0.50mm2 40.1 Ω/km 150/250v
Electrical Data
Product Refer-ence
Size(mm²)
Cores
NominalOD (mm)
± Kg / Km Packing (m) Core Identification Gland Size
2001890 0.22 2 3.5 23 1000 DEF STAN 61-12 00
2001900 0.22 3 4.0 27 1000 DEF STAN 61-12 00
2001910 0.22 4 4.3 30 1000 DEF STAN 61-12 00
2001940 0.22 7 5.5 47 1000 DEF STAN 61-12 00
2001950 0.22 8 5.8 61 1000 DEF STAN 61-12 00
2001960 0.22 10 6.5 65 1000 DEF STAN 61-12 00
2001970 0.22 12 6.5 66 1000 DEF STAN 61-12 00
2002000 0.22 18 7.8 104 1000 DEF STAN 61-12 0
2002020 0.22 20 8.3 110 1000 DEF STAN 61-12 0
2002050 0.22 25 8.8 125 1000 DEF STAN 61-12 0
2002100 0.50 2 5.3 40 1000 DEF STAN 61-12 00
2002110 0.50 3 5.8 48 1000 DEF STAN 61-12 00
2002120 0.50 4 6.8 59 1000 DEF STAN 61-12 00
2002140 0.50 6 7.8 69 1000 DEF STAN 61-12 0
2002150 0.50 7 8.3 81 1000 DEF STAN 61-12 0
2002160 0.50 8 9.4 97 1000 DEF STAN 61-12 0
2002180 0.50 12 10.4 128 1000 DEF STAN 61-12 0
2002200 0.50 16 11.4 150 1000 DEF STAN 61-12 0
2002210 0.50 18 11.9 173 1000 DEF STAN 61-12 0
2002230 0.50 20 12.9 199 1000 DEF STAN 61-12 0
2002260 0.50 25 14.4 254 1000 DEF STAN 61-12 2
2002280 0.50 30 15.4 287 1000 DEF STAN 61-12 2
2002310 0.50 36 17.5 335 500 DEF STAN 61-12 2
Kewberg Cables & Braids (Pty) Ltd.
44
These flexible cables are designed for high
density wiring between components and
within instruments and electronic equipment.
They are extensively used in aircraft, process
control systems, computers, data proces-
sors, military vehicles and military equipment
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Multi Cores—Unscreened Defence Standard 61/12
E&OE
Applications & features
Electrical Data
Construction
Tinned stranded annealed copper conductor, PVC insulated (150/250V), clear polyester tape wrapped. PVC
outer sheath (grey).
Defence Specification
Cables
CONDUCTOR CONDUCTOR VOLTAGE
RESISTANCE RATING
0.22mm2 92.4 Ω/km 150/250v
0.50mm2 40.1 Ω/km 150/250v
Product Refer-ence
Size(mm²)
Cores
Nominal OD(mm)
± Kg / KmPacking
(m)Core Identifica-
tionGlandSize
2000040 0.22 2 3.5 20 1000 DEF STAN 61-12 00
2000060 0.22 3 4.0 24 1000 DEF STAN 61-12 00
2000065 0.22 4 4.3 27 1000 DEF STAN 61-12 00
2000090 0.22 7 5.5 44 1000 DEF STAN 61-12 00
2000100 0.22 8 5.8 58 1000 DEF STAN 61-12 00
2000110 0.22 10 6.5 62 1000 DEF STAN 61-12 00
2000120 0.22 12 6.5 63 1000 DEF STAN 61-12 00
2000150 0.22 18 7.8 101 1000 DEF STAN 61-12 0
2000170 0.22 20 8.3 107 1000 DEF STAN 61-12 0
2000200 0.22 25 8.8 122 1000 DEF STAN 61-12 0
2000310 0.50 2 5.3 37 1000 DEF STAN 61-12 00
2000320 0.50 3 5.8 45 1000 DEF STAN 61-12 00
2000330 0.50 4 6.8 56 1000 DEF STAN 61-12 00
2000350 0.50 6 7.8 66 1000 DEF STAN 61-12 0
2000360 0.50 7 8.3 78 1000 DEF STAN 61-12 0
2000370 0.50 8 9.4 94 1000 DEF STAN 61-12 0
2000390 0.50 12 10.4 125 1000 DEF STAN 61-12 0
2000410 0.50 16 11.4 147 1000 DEF STAN 61-12 0
2000420 0.50 18 11.9 170 1000 DEF STAN 61-12 0
2000440 0.50 20 12.9 196 1000 DEF STAN 61-12 0
2000470 0.50 25 14.4 251 1000 DEF STAN 61-12 2
2000490 0.50 30 15.4 284 1000 DEF STAN 61-12 2
2000520 0.50 36 17.5 332 500 DEF STAN 61-12 2
45
Kewberg Cables & Braids (Pty) Ltd.
45
These cables may be used for main power
distribution in general industries, houses and
commercial buildings. These cables are suit-
able for direct burial installations as well as in
air or ducts. The PVC in LHC and HFFR ar-
moured cable is specially formulated to re-
duce corrosive halogen gasses which are
produced by burning PVC, so are suitable for
use in closed areas such as mines and of-
fices.
Remark: - Cables of sizes not listed above is available on request
Power Cables
Power Cables—Multi-cores Steel Wire Armoured FR PVC 600/1000V
E&OE
Applications & features
Electrical Data
Stranded soft high conductivity copper conductors, PVC insulated, PVC bedding sheath , galvanised single
wire armoured, PVC outer sheath, 600/1000v in accordance with SANS 1507-3 . Cable can be supplied
with flame retardant, low halogen on halogen free outer sheath.
Construction
Product CodeSize
(mm²)Cores
DrumLength
Cable Diameter Gland SizeCable Weight
(kg/km)
4200010 1.5 2 500 13.8 0 360
4200020 1.5 3 500 14.3 0 452
4200030 1.5 4 500 15.1 0 506
4200040 1.5 7 500 17.0 1 629
4200050 1.5 12 500 21.2 2 901
4200060 1.5 14 500 22.0 2 980
4200070 1.5 19 500 25.9 2 1404
4200080 1.5 24 500 29.3 3 1687
4200090 1.5 27 500 29.8 3 1783
4200100 1.5 37 500 32.8 3 2153
Product CodeSize
(mm²)Cores
DrumLength
Cable Diameter Gland SizeCable Weight
(kg/km)
4200110 2.5 2 500 14.7 0 480
4200120 2.5 3 500 15.2 1 523
4200130 2.5 4 500 16.2 1 602
4200130 2.5 7 500 18.5 1 756
4200150 2.5 12 500 24.8 2 1306
4200160 2.5 14 500 25.7 2 1421
4200170 2.5 19 500 28.1 3 1695
4200180 2.5 24 500 32.0 3 2053
4200181 2.5 27 500 32.6 3 2181
4200182 2.5 37 300 37.6 4 3011
Kewberg Cables & Braids (Pty) Ltd.
46
These cables may be used for main power
distribution in general industries, houses and
commercial buildings. These cables are suit-
able for direct burial installations as well as in
air or ducts. The PVC in LHC and HFFR ar-
moured cable is specially formulated to re-
duce corrosive halogen gasses which are
produced by burning PVC, so are suitable for
use in closed areas such as mines and of-
fices.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Power Cables
Power Cables—Multi-cores Steel Wire Armoured FR PVC 600/1000V
E&OE
Applications & features
Stranded soft high conductivity copper conductors, PVC insulated, PVC bedding sheath , galvanised single
wire armoured, PVC outer sheath, 600/1000v in accordance with SANS 1507-3 . Cable can be supplied
with flame retardant, low halogen on halogen free outer sheath.
Construction
Product CodeSize
(mm²)Cores
DrumLength
Cable Diameter Gland SizeCable Weight
(kg/km)
4200190 4.0 2 500 16.3 1 590
4200200 4.0 3 500 17.0 1 668
4200210 4.0 4 500 18.4 1 763
4200220 4.0 7 500 21.0 2 986
4200221 4.0 12 500 28.2 3 1426
4200222 4.0 14 500 29.6 3 1885
4200223 4.0 19 500 32.5 3 2282
4200224 4.0 24 500 38.6 4 3113
4200225 4.0 27 500 39.8 4 3354
47
Kewberg Cables & Braids (Pty) Ltd.
47
It is used in panel and switch gear connec-
tions.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Power Cables
Single Core Flex Panel Wire
E&OE
Applications & features
Stranded or solid, plain or tinned copper conductor, flexible grade PVC insulated, 300/500v and 600/1000v
in accordance with sans 1574, suitable for use at -10 °c to 105 °c - in a range of colours
Construction
STRANDED PANEL WIRE
Product Refer-ence
Size(mm²)
NominalStranding
(No. x strandDiameter)
(mm)
ApproximateOverall Di-
ameter(mm)
Current ratingConductorresistance
VoltageRating
Approx.Cable
weight per100m Coil
(kg)
3800010 0.22 7/0.2 1.2 0.5 92 100 0.4
3800011 0.22 7/0.2 1.6 1 92 300/500v 0.5
3800400 0.50 16/0.2 1.9 2 39 300/500v 0.7
3800405 0.50 16/0.2 2.5 3 39 600/1000v 1.1
3800680 0.75 24/0.2 2.35 5 26 300/500v 1.1
3800685 0.75 24/0.2 2.8 6 26 600/1000v 1.3
3800810 1.00 32/0.2 2.55 8 19.5 300/500v 1.5
3800811 1.00 32/0.2 3.1 10 19.5 600/1000v 1.6
3800090 1.50 30/0.25 2.95 13 13.3 300/500v 2.0
3800095 1.50 30/0.25 3.4 16 13.3 600/1000v 2.2
3800500 2.50 50/0.25 3.8 25 7.98 600/1000v 3.1
3800510 4.00 56/0.30 4.6 32 4.96 600/1000v 4.9
SOLID PANEL WIRE
Product Refer-ence
Size(mm²)
StrandDiameter
(mm)
ApproximateOverall Diame-
ter (mm)
Voltage Rat-ing
Conductorresistance
3800269 0.20 0.50 1.25 100v 89.6
3815050 0.30 0.63 1.63 300/500v 56.4
3801047 0.40 0.71 1.71 300/500v 44.4
3800850 0.50 0.80 1.90 300/500v 35.0
3801050 0.63 0.90 2.00 300/500v 27.6
3801060 0.80 1.00 2.10 300/500v 22.4
Kewberg Cables & Braids (Pty) Ltd.
48
For wiring of lamps, audio systems and se-
curity alarms
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Power Cables
Ripcords
E&OE
Applications & features
Flexible plain copper conductors, PVC insulated
Construction
Product Ref.Size
(mm²)No. ofCores
Approx. CableDiam. (mm)
Conductor resistance @ 20 °C max. (Ω/km)
Approx. Cableweight per 100m
Coil (kg)
0.20 2 92
0.40 2 52
0.50 2 39
0.75 2 26
49
Kewberg Cables & Braids (Pty) Ltd.
49
Used for wiring of extension Cords , Kitchen
Appliances , Power Tools and other general
extension to appliances
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Power Cables
Cabtyre
E&OE
Applications & features
Stranded plain copper conductors, PVC insulated, PVC outer sheath.
Construction
Product Ref.Size
(mm²)No. ofCores
Approx. CableDiam. (mm)
Conductor resistance @ 20 °Cmax. (Ω/km)
Approx. Cableweight per 100m
Coil (kg)
1700010 0.5 2 5.2 39 3.91700040 0.5 3 5.5 39 4.71700070 0.5 4 6.0 39 5.5
1700100 0.75 2 6.2 26 5.21700130 0.75 3 7.0 26 6.7170060 0.75 4 7.2 26 7.8
1700210 1.0 2 6.6 19.5 6.31700240 1.0 3 7.0 19.5 7.61700270 1.0 4 8.0 19.5 9.8
1700300 1.5 2 7.8 13.3 8.41700330 1.5 3 8.3 13.3 10.81700360 1.5 4 9.3 13.3 13.5
1700390 2.5 2 9.6 7.98 13.51700420 2.5 3 10.3 7.98 16.81700450 2.5 4 11.9 7.98 21.8
Voltage Rating Light Duty (LD) 150/250 V
Normal Duty(ND)300/500V
Temperature Range -10°C to 70°C
Sheath colours Black, white, grey
Core colours 2 core - brown and blue
3 core - blue, brown and green/yellow
4 core - black, blue, brown and green/yellow
Kewberg Cables & Braids (Pty) Ltd.
50
It ’s a power cable widely used in power sta-
tion installations.
Remark: - Cables of sizes not listed above is available on request
Power Cables
Unarmoured Power Cables—Eskom Spec
E&OE
Applications & features
Stranded plain annealed copper conductor , PVC insulated and PVC sheathed
sheathing material can be flame retardant PVC, low halogen PVC or halogen free
PVC conductors are colour coded up to 4 core and thereafter black with white numbers. Manufactured to
SANS 1507 as far as applicable.
Construction
Product Ref.Size
(mm²)No ofCores
Eskom code
Maximum Conduc-tor Resistance
(Untinned copper)@ 20 °C max. (Ω/km)
Approx. Cable Diam.(mm)
Gland Size
1600010 1.5 2 BVV02CCV 12.10 8.0 001600020 1.5 3 BVV03CCV 12.10 8.5 01600030 1.5 4 BVV04CCV 12.10 9.3 0
1600040 1.5 7 BVV07CCV 12.10 11.6 1
1600060 1.5 12 BVV12CCV 12.10 15.3 21600080 1.5 14 BVV14CCV 12.10 16.1 21600090 1.5 19 BVV19CCV 12.10 18.4 21600120 1.5 27 BVV27CCV 12.10 22.1 31600130 2.50 2 BVV02DCV 7.41 8.8 01600140 2.50 3 BVV03DCV 7.41 9.3 01600150 2.50 4 BVV04DCV 7.41 10.6 01600170 2.50 7 BVV07DCV 7.41 12.8 11600180 2.50 12 BVV12DCV 7.41 16.9 21600200 2.50 19 BVV19CCV 7.41 20.4 21600220 2.50 27 BVV27DCV 7.41 24.9 31600230 2.50 37 BVV37DCV 7.41 28.2 41600240 4.00 2 BVV02ECV 4.61 10.8 01600250 4.00 3 BVV03ECV 4.61 11.5 11600260 4.00 4 BVV04ECV 4.61 13.1 11600270 4.00 7 BVV07ECV 4.61 15.8 21600290 4.00 12 BVV12ECV 4.61 21.5 31600300 4.00 19 BVV19ECV 4.61 25.8 31600310 6.00 2 BVV02FCV 3.08 12.2 11600320 6.00 3 BVV03FCV 3.08 13.0 11600330 6.00 4 BVV04FCV 3.08 14.7 21600360 10.00 3 BVV03GCV 1.83 14.8 21600370 10.00 4 BVV04GCV 1.83 15.8 21600400 10.00 3 BVV03HCV 1.15 18.3 21600410 10.00 4 BVV04HCB 1.15 20.1 2
51
Kewberg Cables & Braids (Pty) Ltd.
51
It is used to electrically detonate explosives
in mining operations. It has one or two PVC
insulated copper conductors. Two conductor
constructions have the conductors laid paral-
lel like lamp cord, ripcord and HPN. Blasting
wire has no voltage rating.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Mining Cables
Blasting Wire
E&OE
Applications & features
Blasting wire is used on detonation system in the mining industry. Plain solid and stranded annealed copper
conductors PVC insulated, available in various packaging and colour combinations.
Construction
Product CodeSize
(DIA) CoresCONSTRUCTION Packing (m)
1400000 0.50 2 SOLID TWIN TWISTED 100 , 300 , 600 M
1400010 0.50 2 SOLID RIPCORD 100 M
1400020 0.60 1 SOLID SINGLE CORE 1000 M
1400050 0.60 2 SOLID TWIN TWISTED 100 , 300 , 600 M
1400070 0.65 2 SOLID TWIN TWISTED 100 , 300 , 600 M
1700090 0.90 2 SOLID TWIN TWISTED 100 M
1400130 1.12 2 SOLID TWIN TWISTED 100 M
1400160 1.60 2 SOLID TWIN TWISTED
Product CodeSize
(mm2) CoresCONSTRUCTION Packing (m)
1400100 1.50 2 STRANDED TWIN TWISTED 100
1400110 1.50 2 STRANDED FIGURE 8 100
1400170 2.50 2 STRANDED FLAT TWIN 100
1400180 4.00 2 STRANDED FLAT TWIN 100
1400190 4.00 2 PVC/SWA/PVC GREEN 500 M DRUMS
Kewberg Cables & Braids (Pty) Ltd.
52
A highly flexible cable used for lighting the
miners cap lamp from the waist battery.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Mining Cables
Miners Cap Lamp Cable
E&OE
Applications & features
Construction
Flexible annealed tinned copper conductors, PVC insulated and an overall PVC sheath, very flexible sheathing
compound is chemical, oil and abrasion resistant.
The cable is manufactured according to SANS 1438 – 3
Standard Packaging—100 Metre shrink-wrapped coils.
Product CodeSize(mm)
No of Cores
Coil Length
(m)
Approx mass(Kg/100m)
ConductorResistance( Ohms/km)
Cable diameter
1800040 0.5mm2 4 cr 100 8.5 39.0 8.8
1800010 1.0mm2 2 cr 100 10.5 19.6 8.8
53
Kewberg Cables & Braids (Pty) Ltd.
53
Applied in communication and conveyor sys-
tems in the mines.
Remark: - Cables of sizes not listed above is available on request
Mining Cables
Pull Key / Pull Cord
E&OE
Applications & features
Electrical Data
Flexible stranded plain or tinned annealed copper conductor, PVC insulated, PVC bedded or polyester tape
bedding, brass plated steel wire braid, PVC sheathed. The Cable available in various conductor sizes to suit
customer requirements. Cables can also be manufactured to include braided screened cores or pairs if re-
quired. Cores and pairs are colour coded for easy identification.
Cable is also available in flame retardant PVC, low halogen PVC, halogen free PVC or polyurethane.
Construction
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v1.5mm2 12.10 300/500v2.5mm2 7.41 600/1000v
ProductCode
Size (mm²) + cr/pr Construction
MULTICORES - PVC BEDDED
3200190 0.75mm2 x 2 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200240 0.75mm2 x 3 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200340 0.75mm2 x 4 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200745 0.75mm2 x 3 pr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200570 0.75mm2 x 6 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3500600 0.75mm2 x 7 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200620 0.75mm2 x 8 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200660 0.75mm2 x 9 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200110 0.75mm2 x 12 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200150 0.75mm2 x 16 cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3200740 1.0mm2 x 4 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
3200790 1.0mm2 x 5 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
3200690 1.0mm2 x 10 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
3200870 1.5mm2 x 10 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
3201030 1.5mm2 x 4 cr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
3201060 1.5mm2 x 6 cr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
3201100 1.5mm2 x 6 pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
3201800 2.5mm2 x3 cr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
Kewberg Cables & Braids (Pty) Ltd.
54
Applied in communication and conveyor sys-
tems in the mines.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Mining Cables
Pull Key / Pull Cords
E&OE
Applications & features
Construction
Electrical Data
CONDUCTOR CONDUCTOR VOLTAGE
AREA RESISTANCE RATING
0.75mm2 24.50 300/500v
1.0mm2 18.10 300/500v1.5mm2 12.10 300/500v2.5mm2 7.41 600/1000v
ProductCode
Size (mm²) + cr/pr Construction
MULTICORES - POLYESTER TAPEBEDDED
3200575 0.75X6cr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath
COMBINATION CABLE - PVC BEDDED
3200480 0.75mm2x4cr+3.10mm2x2cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3200990 1.5mm2x2cr+0.75mm2x2pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath3201010 1.5mm2x2cr+0.75mm2x3pr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201470 2.5mm2x2cr+0.75mm2x4cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201610 2.5mm2x2cr+0.75mm2x6cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201700 2.5mm2x2cr+1.0mm2x4cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201840 2.5mm2x3cr+1.5mm2x3cr Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201850 4.0mm2x2cr+0.75mm2x4cr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath3201860 2.5mm2x4cr+0.75mm2x2pr Plain Copper , PVC Bedding, BPSW Braid , PVC Sheath
COMBINATION CABLE - POLYESTERTAPE BEDDED
3200900 1.5mm2x2cr+0.75mm2x3cr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath3200970 1.5mm2x2pr+0.75mm2x2pr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath3200730 2.5mm2x2cr+1.0mm2x4cr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath3201780 2.5mm2x2cr+1.5mm2x4cr Tin Copper , Tape Bedding ,BPSW Braid , PVC Sheath
CABLES WITH PLAIN COPPER BRAIDSCREENED CORES
3200280 0.75mm2x3cr + 1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3200390 0.75mm2x4cr + 2cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201300 2.5mm2x2cr+0.75mm2x2cr+1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath3201380 2.5mm2x2cr+0.75mm2x3cr+1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3201520 2.5mm2x2cr+0.75mm2x4cr+1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
3201600 2.5mm2x2cr+0.75mm2x5cr+1cr PCB Tin Copper , PVC Bedding ,BPSW Braid , PVC Sheath
55
Kewberg Cables & Braids (Pty) Ltd.
55
This is a specialized product used for submersi-
ble pumps in deep well in quarries, mines, sew-
age plants and cleaning equipment. The area of
installation is physically restrictive, and where
the environment is hostile.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Submersible Pump Cable
E&OE
Applications & features
Identification
Stranded plain annealed flexible copper conductor, flexible grade waterproof PVC insulated, (600/1000V),
cores laid and flexible grade waterproof PVC sheathed, cable in accordance with SANS1574, suitable for
temperature range of –10°C to +70°C conductors in accordance with SANS 1411 Part 1. Standard packag-
ing –500 metre drums or 100 metre coils.
Construction
Outer Sheath colours: 3 core -Blue, 4 Core –Green
Core Identification: 3 core –Red, Yellow, Blue
Core Identification: 4 core –Red, Yellow, Blue, Black
Size(mm²)
No. ofCores
NominalStranding
(No. xstrand di-ameter)
(mm)
Approx.CableDiam.(mm)
Conductorresistance @
20 °C max.(Ω/km)
Current ratingin Air @
30 °C andConductortemp. 70 °C
(A)(1 Phase)
Volt Drop(mV/A/m)
220V(1 Phase)
Volt Drop(mV/A/m)
380V(3 Phase)
Approx.Cable
weight (kg/m)
1.5 3 44/0.2 10.2 13.30 15 29 25 0.2
2.5 3 72/0.2 11.7 7.98 20 17 15 0.2
4 3 112/0.2 13.5 4.96 30 12 9.5 0.3
6 3 175/0.2 15.1 3.30 35 7.3 6.4 0.5
10 3 294/0.2 17.6 1.91 50 4.3 3.8 0.6
16 3 125/0.4 20.1 1.21 65 2.8 2.4 0.8
1.5 4 44/0.2 11.2 13.30 15 29 25 0.2
2.5 4 72/0.2 12.8 7.98 20 17 15 0.25
4 4 112/0.2 14.6 4.96 30 12 9.5 0.35
6 4 175/0.2 16.5 3.30 35 7.3 6.4 0.5
10 4 294/0.2 19.2 1.91 50 4.3 3.8 0.7
16 4 125/0.4 22.0 1.21 65 2.8 2.4 1.0
Kewberg Cables & Braids (Pty) Ltd.
56
It is a flexible cable normally used for wiring
of portable and mobile machinery. Also used
in temporary power supply on medium duty
industrial applications, workshops and ma-
chinery.
Other applications is on power supply on ar-
eas requiring oil and water resistance.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
PVC NITRILE FLEXIBLE TRAILING CABLE
E&OE
Applications & features
Stranded plain annealed flexible copper conductor, flexible grade PVC insulated and bedded (600/1000V),
cores laid up and flexible grade PVC / nitrile sheathed cable in accordance with SANS1574, suitable for a
temperature range of –10°C to +70°C conductors in accordance with SANS1411 Part 1. Standard packaging
– 500 metre drums or 100 metre coils.
Construction
Identification
Size(mm²)
No. ofCores
NominalStranding
(No. xstrand di-ameter)
(mm)
Approx.CableDiam.(mm)
Conductorresistance @
20 °C max.(Ω/km)
Current rat-ing in Air
@ 30 °C andConductortemp. 70 °C
(A)(1 Phase)
Volt Drop(mV/A/m)
380V(3 Phase)
CCG A2Cable
Gland Size
Approx. Cableweight (kg/m)
1.5 4 44/0.2 11 13.3 15 2900-20ss
0.2
2.5 4 72/0.2 13 7.98 20 171-20
0.3
4 4 112/0.2 15 4.96 30 122-25
0.4
6 4175/0.2
17 3.30 35 7.32-25
0.5
10 4294/0.2
20 1.91 50 4.32-25
0.7
16 4 125/0.4 23 1.21 65 2.82-25
1.0
Outer Sheath colours: Orange
Core Identification: 4 core –Red, Yellow, Blue, Black
57
Kewberg Cables & Braids (Pty) Ltd.
57
It is for indoor telephone installations
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
INDOOR TELEPHONE CABLE
E&OE
Applications & features
Solid annealed copper conductor (plain), PVC insulated, white PVC sheathed indoor telephone cable to
Telkom spec 268 / 271
Construction
Size(mm)
PairsNominal OD
(mm)Cable weight
(Kg / m)Total weight /1000m drum
Maximum conduc-tor loop resistance
(Ω / km)
Minimum insulationresistance (MΩ-km)
0.5 2 3.8 2 49 186.4 37.5
0.5 3 5.1 3 96 186.4 37.5
0.5 4 5.6 4 67 186.4 37.5
0.5 5 5.8 4 109 186.4 37.5
0.5 6 6.8 5 117 186.4 37.5
0.5 10 8.4 9 146 186.4 37.5
0.5 15 9.7 11 178 186.4 37.5
0.5 20 10.7 15 213 186.4 37.5
0.5 25 11.4 18 243 186.4 37.5
0.5 30 11.7 21 291 186.4 37.5
0.5 40 14.2 27 358 186.4 37.5
0.5 50 16.0 35 429 186.4 37.5
0.5 75 18.0 51 570 186.4 37.5
0.5 100 22.8 69 752 186.4 37.5
Kewberg Cables & Braids (Pty) Ltd.
58
For telephone installation , recommended for
burial
Remark: - Cables of sizes not listed above is available on request
Special Cables
OUTDOOR TELEPHONE CABLE - STEEL WIRE ARMOURED
E&OE
Applications & features
Plain annealed solid copper conductor, PVC insulated, PVC bedding sheathed, galvanised steel wire ar-
moured, PVC sheathed . Also available in flame retardant PVC, low halogen PVC and halogen free PVC.
Other constructions on request
Construction
Product Refer-ence
Size(mm)
PairsNominalOD (mm)
Cable weight(Kg / 100 m)
Totalweight /
1000m drum
Maximum con-ductor loopresistance
(Ω / km)
Minimum insu-lation resis-
tance (MΩ-km)
4300010 0.6 2 9.5 21.4 278 129.4 37.5
4300020 0.6 4 11.5 28.9 353 129.4 37.5
4300030 0.6 5 12.0 31.5 380 129.4 37.5
4300040 0.6 6 12.5 34.9 414 129.4 37.5
4300100 0.6 10 14.0 41.1 476 129.4 37.5
4300111 0.6 15 15.5 51.2 635 129.4 37.5
4300112 0.6 20 16.5 58.1 662 129.4 37.5
4300113 0.6 30 18.0 67.2 730 129.4 37.5
4300114 0.6 40 20.0 85.8 553 129.4 37.5
4300115 0.6 51 24.0 124.0 852 129.4 37.5
4300130 0.9 4 13.0 36.9 450.0 55.8 37.5
4300140 0.9 5 14.0 42.0 485.0 55.8 37.5
4300150 0.9 6 14.5 46.1 543.0 55.8 37.5
4300160 0.9 10 16.0 57.9 661.0 55.8 37.5
4300161 0.9 15 18.5 74.2 453.0 55.8 37.5
4300162 0.9 20 19.5 86.4 514.0 55.8 37.5
4300163 0.9 30 24.5 136.3 805.0 55.8 37.5
4300164 0.9 40 26.5 160.2 970.0 55.8 37.5
4300165 0.9 51 29.5 192.3 1194.0 55.8 37.5
59
Kewberg Cables & Braids (Pty) Ltd.
59
The cables are used in security system instal-
lations. They are widely applied in commer-
cial, domestic and industrial buildings and in
public ways.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Security Cables—Solid and Stranded Multicores, Ripcords and Cabtyres
E&OE
Applications & features
Solid conductors: Colour coded solid copper PVC insulated and PVC sheathed, available in white, brown
and black.
Construction
Product Code Size (DIA)Cores
Nominal OD(mm)
± Kg / 100m Packing (m)
3500170 0.45 4 1.2 100
3500180 0.45 6 1.8 100
3500190 0.45 8 2.4 100
3500200 0.45 10 3.0 100
3500210 0.45 12 3.6 100
3500220 0.45 16 4.0 100
3500230 0.45 20 5.4 100
3500240 0.45 30 8.0 100
Product Code Size (mm2) CoresNominal OD
(mm)± Kg / 100m Packing (m)
3500390 0.20 4 2.0 100
3500400 0.20 6 2.6 100
3500410 0.20 8 3.2 100
3500420 0.20 10 3.8 100
3500430 0.20 12 4.6 100
3500440 0.20 20 8.0 100
3500450 0.20 30 12.0 100
Stranded conductors: Colour coded multi stranded copper conductors PVC insulated and PVC sheathed,
available in white, brown and black.
Kewberg Cables & Braids (Pty) Ltd.
60
The cables are used in security system instal-
lations. They are widely applied in commer-
cial, domestic and industrial buildings and in
public ways
Ripcords
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Security Cables—Solid and Stranded Multicores, Ripcords and Cabtyres
E&OE
Applications & features
Solid annealed plain copper conductor, PVC insulated, aluminium/ mylar foil screened, tinned stranded cop-
per drain wire, flame retardant PVC sheathed (red or white)
Construction—Light Duty Cabtyre
Product Code Size (mm2)
Cores
Nominal OD(mm)
± Kg / 100m Packing (m)
0.50 3 4.0 100
Product CodeSize
(mm2)Cores
Nominal OD(mm)
± Kg / 100m Packing (m)
3500390 0.20 2 1.0 100
3500400 0.40 2 1.6 100
3500410 0.50 2 2.2 100
61
Kewberg Cables & Braids (Pty) Ltd.
61
Wiring of fire alarms, fire protective circuits,
burglar alarms, smoke alarms, and voice
communications
Stranded annealed plain copper conductor, PVC insulated, aluminium/mylar foil screened tinned stranded
copper drain wire, flame retardant PVC sheathed (red or white).
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Fire Alarm Cables
E&OE
Applications & features
Solid annealed plain copper conductor, PVC insulated, aluminium/ mylar foil screened, tinned stranded
copper drain wire, flame retardant PVC sheathed (red or white)
Construction
Product CodeSize(DIA)
No of pairs /coresNominal OD
(mm)± Kg / Km Packing (m) Gland Size
2100010 0.80 2 cr 4.0 83 1000 00
2100020 0.80 4 cr 4.9 94 1000 00
2100030 0.80 8 cr 6.5 134 1000 00
2100060 1.12 2 pr 6.4 98 1000 00
Product CodeSize
(mm2)Cores
Nominal OD(mm)
± Kg / Km Packing (m) Gland Size
2100075 1.00 25 6.0 90 1000 00
2100080 1.50 30 7.0 103 1000 00
Kewberg Cables & Braids (Pty) Ltd.
62
A higher wattage, heavy-duty cable system
that is designed to be installed within the
concrete screed of a new building or exten-
sion. A very cost-effective solution for new
home constructions
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Underfloor Heating Cable
E&OE
Applications & features
Galvanised steel wire with or without a solid plain copper wire supplied in various colours each with differ-
ent conductor resistance and packaging lengths for various heating applications. All wire insulated with a
high temperature PVC.
Construction
Product Code Colour
NominalOverall di-mension
(mm)
Cu (Dia)Galvanised
Steel Wire( Dia)
Meters per CoilMaximum conductor
resistance(Ω / Coil at 20°C)
4500010 Grey 4.00 3x0.30mm 1000 608.00
4500020 White 4.00 0.25 3x0.30mm 100 22.10
4500030 Violet 4.00 0.31 3x0.30mm 165 27.80
4500030 Violet 4.00 0.31 3x0.30mm 250 42.10
4500060 Yellow 4.00 0.45 3x0.30mm 200 18.65
4500060 Yellow 4.00 0.45 3x0.30mm 210 19.60
4500070 Orange 4.00 0.55 3x0.30mm 250 16.35
4500070 Orange 4.00 0.55 3x0.30mm 375 24.50
4500080 Red 4.00 0.76 3x0.30mm 330 12.10
4500080 Red 4.00 0.76 3x0.30mm 500 18.30
4500090 Dark Green 4.00 0.85 3x0.30mm 370 10.90
4500100 Pink 4.00 4x0.30mm 100 45.60
4500100 Pink 4.00 4x0.30mm 110 50.20
4500100 Pink 4.00 4x0.30mm 200 91.20
63
Kewberg Cables & Braids (Pty) Ltd.
63
RUNWAY LIGHTING CABLE is designed for
burial beside runways, to power the lights that
guide aircraft to safe landings and take offs.
It has a thick covering of polyethylene and a
shielding of tinned copper braid.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Runway Lighting Cable
E&OE
Applications & features
The conductor comprises single 6mm2 cross-sectional area multi strand tinned annealed copper wire.
Polyethylene insulation provides the cable with superior electrical and mechanical characteristics, screened
with tinned copper braid and sheathed with a flame retardant PVC.
Construction
Kewberg Cables & Braids (Pty) Ltd.
64
Cables for elevators and cranes (Internal and
Panoramic).
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Flat Elevator / Crane Cable
E&OE
Applications & features
Flat crane cable has flexible copper conductors class 5 annealed copper conductors, 4core cable is colour
coded blue, brown, yellow/green earth conductor. The sheath is a flexible grade PVC.
Construction
Product Code Size (mm²) No. Of CoresCable Dia (Width x
Height)Kg/1000m
2200010 1.5mm2 4 15x5 200.0
2200020 1.5mm2 8 28x5 600.0
2200030 1.5mm2 12 40x5 950.0
2200040 2.5mm2 4 18x5.8 290.0
2200050 2.5mm2 8 37x5.8 740.0
2200060 2.5mm2 12 50x5.8 1260.0
2200070 4.0mm2 4 21x6.8 410.0
2200080 4.0mm2 7 38x6.9 750.0
2200100 6.0mm2 4 24x7.6 520.0
2200110 10.0mm2 4 30x9.6 800.0
2200120 16.0mm2 4 24.5x10.9 1150.0
2200130 25.0mm2 4 41.5x12.5 1800.0
2200140 35.0mm2 4 49x15.8 2200.0
65
Kewberg Cables & Braids (Pty) Ltd.
65
The cable is used for overhead crane control
system
They are built to withstand mechanical stress
wihile allowing for control.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Pendant Crane Cable
E&OE
Applications & features
Electrical Data
Crane pendant cable consists of plain annealed copper, black PVC insulated conductors with green, yellow
earth. The cable is strengthened by 2 steel wire ropes extruded in the outer PVC sheath.
Construction
Product CodeSize
(mm²)No. Of Cores
Cable Diameter (Widthx Height)
Kg/1000m
2200150 1.0mm2 14 16X26 400
2200160 1.0mm2 27 22X34 700
2200170 1.5mm2 8 16X28 420
2200180 1.5mm2 12 17X28 510
2200190 1.5mm2 20 21X34 720
Kewberg Cables & Braids (Pty) Ltd.
66
Seismic cable is used for seismic detection
devices mainly used in mines to monitor
breaths and slips of the earths tectonic
plates.
Remark: - Cables of sizes not listed above is available on request
Diameter and weights are representative figures and may vary by +- 5%
Special Cables
Seismic Detection Cable
E&OE
Applications & features
Plain annealed solid copper conductor, polyethylene insulated, either individual or overall screening with a
tinned copper drain wire, PVC bedding, galvanised steel wire armoured and PVC sheathed. The outer
sheath can be flame retardant PVC, low halogen or halogen free PVC.
Construction
Product Code Size (mm) Pairs Drum LengthApprox mass
(Kg)Conductor Resis-tance ( Ohms/km)
Cable diameterGlandSize
OVERALLSCREENED
3600180 0.8 2 pr 500 240 36.0 13.8 0
3600190 0.8 4 pr 500 288 36.0 15.5 0
3600200 0.8 6 pr 500 345 36.0 17.0 1
3600210 0.8 8 pr 500 398 36.0 18.5 1
3600220 0.8 10 pr 500 480 36.0 19.9 2
3600230 0.8 12 pr 500 560 36.0 21.2 2
3600240 0.8 20 pr 500 852 36.0 24.2 2
3600250 0.8 32 pr 500 1010 36.0 28.5 3
INDIVIDUALSCREENED
3600010 0.8 2 pr 500 260 36.0 14.4 0
3600020 0.8 4 pr 500 305 36.0 15.9 0
3600030 0.8 6 pr 500 365 36.0 17.6 1
3600040 0.8 8 pr 500 440 36.0 19.5 2
3600050 0.8 10 pr 500 510 36.0 21.1 2
3600060 0.8 12 pr 500 590 36.0 22.0 2
3600070 0.8 20 pr 500 890 36.0 26.6 3
3600080 0.8 32 pr 500 1050 36.0 32.8 4
67
Material
Insulation Material
Chemical description
Short
symbol
accordin
g to DIN
76722
Classi-
fication
acc. to
ISO
6722
Continuou
s duty
temp.
(3.000 h)
°C
Thermal
overload
capacity
°C / 48 h
Cold
bending
resistanc
e °C
Specific
resistance
at 20 °C
Ω x cm
Shore
hardnes
s A/D
Tensile
strength
MPa
Elongation
at break
% Abrasion
Flame
retardant Oil Fuel
Brake
Fluid
Acid/
Lye
Organic
compound
s
PVC Polyvinyl Chloride Y (YW) A/B 90 / 105 140 -40 > 10¹² A85-95 > 10 > 150 + + + + - + -
XPVC
Irradiation cross-linked
PVC-compounds X A/B 90 / 105 140 -40 > 10¹² A85-95 > 10 > 150 ++ + + + + + +
PE Polyethylene 2Y B 100 100 -50 > 1016
D45-55 > 15 > 300 + -- - + - ++ -
TPE-E
Thermoplastic Polyester-
Elastomer Hytrel® 13Y C 110 150 -40 > 1010
D40-78 > 25 > 300 ++ - ++ ++ + - +
TPE-U
(PUR)
Thermoplastic
Polyurethane-Elastomer
Elastollan® 11Y C 125 150 -50 > 109
A75-D54 > 30 > 300 ++ - ++ ++ + + +
XPE
Irradiation cross-linked
PE-compounds 2X C/D 125 200 -40 >1013
A95-D50 >10 >100 + + + + + + +
EVA
Ethylene-Vinylacetate-
Copolymer-compounds 4G C 130 160 -40 >1013 A80-90 > 10 > 200 + - + + + + +
HX
Irradiation cross-l inked
Copolymer-compounds – D 150 200 -40 > 1011
A92 > 10 > 100 + + + + + + +
XTPE-E
Irradiation cross-l inked
Polyester-Elastomer-
compounds 12X D 150 200 -40 >1011
A88 >15 >200 +/- + ++ ++ ++ ++ ++
PVDFPolyvinylidenfluorid
Dyflor® Kynar® 10Y D 155 160 -65 >1014 D75-80 > 20 > 100 ++ +(+) ++ ++ ++ ++ +
ETFE
Ethylen-Tetrafluor-
ethylen-Copolymer
Hostaflon®-ET Tefzel® 7Y E 180 230 -65 >1016
D75-80 > 30 > 150 ++ +(+) ++ ++ ++ ++ ++
FEP
Perfluorethylen-
propylen-Copolymer
Hostaflon®-FEP Teflon®-
FEP 6Y F 210 240 -65 >1016 D55-60 > 15 > 200 ++ ++ ++ ++ ++ ++ ++
PFA
Perfluoralkoxy-
Tetrafluorethylenco-
polymer Hostaflon®-PFA
Teflon®-PFA 14Y H 260 270 -65 >1017
D55-65 > 20 > 200 ++ ++ ++ ++ ++ ++ ++
PTFE
Polytetrafluorethylene
Hostaflon®-TF Teflon®-
PTFE 5Y H 260 310 -65 >1017 D55-65 > 20 > 200 ++ ++ ++ ++ ++ ++ ++DuPontRegisteredTradeMarks: Othertrademarks
Hytrel,Teflon,Tefzel Elastollanisaregisteredtrademark ofElastogranGmbH Dyfloris aregistred trademarkof Evonik(previouslyDegussa)
HostaflonisaregisteredtrademarkofHoechst,Germany. Kynarisa registeredtrademarkof ArkemaInc.
Thermal Properties Resistance to various:
PRODUCTS ANY CABLE AND CABLE RELATED PRODUCTS NOT LISTED IN THIS CATALOGUE
SOURCING SOURCING OF CABLE & RELATED PRODUCTS, LOCALLY AND INTERNATIONALLY
SERVICES OVER-SHEATHING & ARMOURING OF EXISTING CABLES WITH THE FOLLOWING
SHEATHING WITH THE FOLLOWINGFR (Flame Retardant),
LH (Low Halogen, Blue stripe),ZH (Zero Halogen, White stripe)
ARMOURING WITH THE FOLLOWINGSWA (Steel Wire Armour)
APL ( Aluminium-Polyethylene-Laminate)AVL (Aluminium-Vinyl-Laminate ) in FR, LHFR and ZHFR
FR Flame Retardant
LH Low Halogen
LHFR Low Halogen Flame Retardant
ZH Zero Halogen
HFFR Halogen Free Fire Retardant
SWA Steel Wire Armour
APL Aluminium-Polyethylene-LaminateAVL Aluminium-Vinyl-LaminateOAM Overall Mylar* (Screen)IOAM Individual and Overall Aluminium / Mylar* (Screen)TCB Tinned Copper Braid
PCB Plain Copper Braid
D/W Drain Wire
PVC Poly Vinyl Chloride
XLPE Cross Linked Polyethelen
PE Polyethelene
TC Tinned Copper
PC Plain Copper
PR Pairs
C Cores
TR Triads
STR Stranded
PC Plain Copper Cores
1.5mm² Size of the conductors
4 Qty of Conductors
Pr Conductors in a Twisted Pair Construction
XLPE Cross linked Polyethelene insulation
IOAM Ind ividual and Over All Mylar (Screen)
D/W Drain Wire
SWA Steel Wire Armour
HFFR Halogen Free Fire Retardant oversheath
1.5mm² x 4 PR STR PC XLPE IOAM + D/W SWA HFFR
MEASURING RE-MEASURING AND RE-DRUMMING OF CABLE
OTHER PRODUCTS AND SERVICES
MANUFACTURING OF SPECIAL CABLESSpecial cables can be manufactured according to your specifications.
Composite Cables can be manufactured according to your specifications and requirements
TYPICAL CABLE ABBREVIATIONS
TYPICAL CABLE CONSTRUCTION DETAILS
69
CONDUCTOR STRANDING TO VDE 0295 & IEC 60228
Crosssection(mm²)
Conductor stranding toDIN VDE 0295 Class 2
No. of wires / wire di-ameter
Multi-Conductorstranding to
VDE 0295No. of wires / wire
diameter
Conductor strandingto VDE 0295
Class 5No. of wires / wire
diameter
Superfine Conductorstranding to VDE
0295 Class 6No. of wires / wire
diameter
0.14 18/0.10
0.25 14/0.15 32/0.10
0.34 7/0.25 19/0.15 42/0.10
0.5 7/0.3 7/0.3 16/0.2 28/0.15
0.75 7/0.37 7/0.37 24/0.2 42/0.15
1 7/0.43 7/0.43 32/0.2 56/0.15
1.5 7/0.52 7/0.52 30/0.25 84/0.15
2.5 7/0.67 19/0.41 50/0.25 140/0.15
4 7/0.85 19/0.52 56/0.30 224/0.15
6 7/1.05 19/0.64 84/0.30 192/0.2
10 7/1.35 49/0.51 80/0.40 320/0.2
16 7/1.70 49/0.65 128/0.40 512/0.2
25 7/2.13 84/0.62 200/0.40 800/0.2
35 7/2.52 133/0.58 280/0.40 1120/0.2
50 19/1.83 133/0.69 400/0.40 705/0.3
70 19/2.17 189/0.69 356/0.50 990/0.3
95 19/2.52 259/0.69 485/0.50 1340/0.3
120 37/2.03 336/0.67 614/0.50 1690/0.3
150 37/2.27 392/0.69 765/0.50 2123/0.3
185 37/2.52 494/0.69 944/0.50 1470/0.4
240 61/2.24 627/0.7 1225/0.50 1905/0.4
300 61/2.5 790/0.7 1530/0.50 2385/0.4
400 61/2.89 2035/0.50
500 61/3.23 1768/0.60
630 91/3.23 2286/0.60
Kindly note that in accordance with VDE 0295 only the maximum diamemeter and resistance of the conductor is specified
AMERICAN WIRE GUAGE TO ACTUAL METRIC AREA (mm²) & CONDUCTOR RESISTANCE
AWG /MCM num-
ber
Conductor Cross-sectional area
(mm²)
Conductor diameter(mm)
Conductor resistance(Ω / km)
AWG number
ConductorCross-
sectionalarea (mm²)
Conductordiameter
(mm)
Conductorresistance
(Ω / km)
1000 MCM 507 29.3 0.036 15 1.65 1.45 11.2
900 MCM 456 27.8 0.04 16 1.31 1.29 14.7
750 MCM 380 25.4 0.048 17 1.04 1.15 17.8
600 MCM 304 22.7 0.061 18 0.823 1.024 23
550 MCM 279 21.7 0.066 19 0.653 0.912 28.3
500 MCM 253 20.7 0.07 20 0.519 0.812 34.5
450 MCM 228 19.6 0.08 21 0.412 0.723 44
400 MCM 203 18.5 0.09 22 0.324 0.644 54.8
350 MCM 177 17.3 0.1 23 0.259 0.573 70.1
300 MCM 152 16 0.12 24 0.205 0.511 89.2
250 MCM 127 14.6 0.14 25 0.163 0.455 111
4/0 107.2 11.68 0.18 26 0.128 0.405 146
3/0 85 10.4 0.23 27 0.102 0.361 176
2/0 67.4 9.27 0.29 28 0.0804 0.321 232
1/0 53.4 8.25 0.37 29 0.0646 0.286 282
1 42.4 7.35 0.47 30 0.0503 0.255 350
2 33.6 6.54 0.57 31 0.04 0.227 446
3 26.7 5.83 0.71 32 0.032 0.202 578
4 21.2 5.19 0.91 33 0.0252 0.18 710
5 16.8 4.62 1.12 34 0.02 0.16 899
6 13.3 4.11 1.44 35 0.0161 0.143 1125
7 10.6 3.67 1.78 36 0.0123 0.127 1426
8 8.34 3.26 2.36 37 0.01 0.113 1800
9 6.62 2.91 2.77 38 0.00795 0.101 2255
10 5.26 2.59 3.64 39 0.00632 0.0897 2860
11 4.15 2.3 4.44 39 0.00632 0.0897 2860
12 3.31 2.05 5.41 40 0.00487 0.079 3802
13 2.63 1.83 7.02 42 0.00317 0.064 584214 2.08 1.63 8.79 44 0.00203 0.051 9123
Note: 1 CM = 1 Circ. Mil = 0.0005067 mm² and 1 MCM = 1000 Circular mils = 0.5067 mm²
71
Phone: +27 (0 11) 908 5165
Fax: +27 (0 11) 864 6812
Fax: +27 (0 11) 908 1261
E-mail: [email protected]
9 Clarke Street
Alrode, Alberton
1450
Johannesburg, South Africa
P O Box 124379,
Alrode, 1451
Alberton, South Africa
Kewberg Cables & Braids (Pty) Ltd.