Magnetic Property Measurement System
MPMS XL
Configurations
MPMS XL is offered in 2 configurations
MPMS XL-5 (5 Tesla)
MPMS XL-7 (7 Tesla)
Principal components of this measurement systemTemperature Control System ( 1.7 K to 400 K) Magnet Control System ( 5 T)Sample Handling SystemComputer Operating SystemSuper conducting SQUID Amplifier System
Sample rodSample rotatorSample transportProbe assemblyHe level SensorSuperconducting SolenoidFlow ImpedanceSquid capsule with magnetic shieldSuperconducting pick-up coil
10. Dewar Isolation cabinet11. Dewar12. Printer13. Magnetic power supply14. Temp. controller15. Console Cabinet16. Power distribution unit17.MPMS controller18. Gas/Magnet control unit19. Computer20. Monitor
Specifications of MPMS XL-5
Field =5 TeslaTemperature=1.7K to 400 KSweeping rate=0.001K to 10K/Min
Possible MeasurementsMagnetization vs. Temperature (M vs. T):Default settings: 300K-10K, Temperature interval 5K Zero Field Cooling Field Cooling AC SusceptibilityMagnetization vs. Field (M vs. H):Default settings: -5T to +5T step size 0.5T HysteresisHysteresis
Features of MPMS MultiVu SoftwareSimultaneous Access to all aspects of system operation: sequence setup,data analysis,data display
Enables multiple documents and view to be visible and useable at the same time
Simultaneous display of data files in multiple formats (e.g.. Graphs vs. texts)Automated Background Subtraction
SQUID Magnetometer Facility
(Division of Chemical Sciences)
Request Form:
Date of Submission:
Sample name:
Email Id: Phone No:
Experiment details:
1.Magnetisation Vs Temperature (M vs. T)
Temperature Range (Default settings: 300K-10K, Temperature interval 5K):
Magnetic Field (0-5T):
(Typical measurement time for default settings: 7hours)
2.Magnetisation Vs Field (M vs. H)
Field (Default settings: -5T to +5T step size 0.5T):
Temperature:
(Typical measurement time for default settings: 6hours)
Note: If you require M vs H measurement at more than two temperatures, please submit a separate request form.
Signature of the Research Supervisor
OPERATORES USE
Time taken :
Date of completion:
LimitationsMeasurement of hysteresis at more than two temperatures is considered as II sampleMeasurement below 10K also considered as II sample (because it is necessary for the instrument to be stable at 10K at least for 1 hour before going below 10K)Sample should be submitted only on Friday
Total Number of Measurements Done
Total Number of Working days =Total = Physics = SSCU = MRC = ISU = Metallurgy = Outside = IPC =