Magnetic Lock - Double (EM-NH2500M)

Embed Size (px)

Citation preview

  • 7/30/2019 Magnetic Lock - Double (EM-NH2500M)

    1/2

    Statement

    Features

    Specifications

    The NH series electromagnet lock is an important mountingplate design breakthrough. The mounting plate is designedw i th a w el l engi neer ed s l idi ng mechani s m t hat makes

    electromagnet considerably easy to clasp the mounting plateto allow security of use and maximize the ease of installation.T her efor e, ev en i f us ed f or l onger peri ods , t he t r ic k yinnovation in i ts design will prevent the electromagnet ofbeing falling when the screw are loosening up .

    The EM-NH2500 Series are high quality and safety range ofstandard fail-safe electromagnetic locks that is simply, workswell in order to effectively secure with doors.

    andis suitable for fire doors and emergency exit doors.

    It is surfacemounted face to face locks offering up to 1200 X 2 poundsholding force which this lock is recommended for applicationswhich require higher levels of access and egress control

    GIANNI INDUSTRIES, INC.

    No.306-1, Hsin Shu Road, Hsin Chuang, Taipei,Taiwan 242TEL: 886-2-2206 9929 FAX: 886-2-2204 6632E-Mail: [email protected]: gianni.tw

    Copyright 2008 Gianni industries, inc. All rights reserved.DM-CA-EM-NH2500 Ver. D Published on 2008.08.18

    The products are manufactured under an ISO

    9 00 1 Q C 08 00 00 C er ti fi ed Q ua li tyManagement Program environment back i t sproduct quality, performance and commitmentto customer satisfaction.

    &

    GP001

    Fasten the mounting plate ont h e s i t e t h e n i n s t a l le l e ct r om a g ne t l o c k w i thpower l ead c abl e t hroughmountingplateslothole.

    For assembling the mountingplate and the electromagnetlock into the groove, pleasem ak e t he m ar k o n t hemounting plate and the mark

    on the electromagnet lockitself to be a straight line foral ignment. Either al igningfrom left side or from r ightsideisfeasible.

    S l ide t he el ect r omagnet i clock to fit with the mountingplate as the drawing. Oncet h e c o rr e ct p o s it i o n i sencountered, use the AllenWrench to fasten the fixingscrews through the bottom ofthe electromagnet lock intothemountingplate.

    A f t e r t h e e l e c t r o m a g n e tfirmly assembled with them o un t in g p l at e , u s e t h escrews to fasten the lock onthesitepermanently.

    Cable

    Special Mounting Plate design

    EM-NH2500DoubleStandardElectromagnetic Lock

    Offers up to 1200 X 2 LBS Holding Force.Magnetic bond sensor monitor output.Anodized aluminum housing.Groove template & housing for easy installation.Dual voltage 12 or 24 VDC selectableAnti-Residual magnetism designed.Complete mounting hardware included.

    ( ).

    Voltage Tolerance: 15%

    Current Draw:500mA x2@12Vdc;250mAx2@24Vdcat 20 degree centigrade

    Operating Temperature from -10 to 55 degreecentigradeHumidity: 0~95% non-condensing.Holding Force: Up to 1200 lbs (545 Kg) X2Dimensions:

    Magnet:(L) 534, (W) 71, (D) 40 mmArm at ur e Pla te :( L) 185, (W) 62, (D) 16 mmMounting Plate:(L) 534, (W) 40, (D) 8 mm

    Finishes for magnet and armature plate: ZincEpoxy Potting Compound: E87252 (S), UL94V-0Weight (Approx.): 9.6 Kg

    ( )

    The product is warranted against defects in material andworkmanship while used in normal service for a period of 5year from the date of sale to the original customer. The GEMpolicy is one of continual development and improvement;therefore GEM reserves the right to change specifications

    without notice.

    Warranty

    Patent

    ZL 2006 2 0122522.X (China)Nr. 20 2006 012 052.1(Germany)M308308 (Taiwan)GB 06 1 6099.8 (Great Britain)06 07229 (France)

    Patent:ZL 2006 2 0122522.XNr. 20 2006 012 052.1M308308GB 06 1 6099.806 07229 (France)

  • 7/30/2019 Magnetic Lock - Double (EM-NH2500M)

    2/2

    LZ-NH2500N

    GIANNI INDUSTRIES, INC.

    No.306-1, Hsin Shu Road, Hsin Chuang, Taipei,Taiwan 242TEL: 886-2-2206 9929 FAX: 886-2-2204 6632E-Mail: [email protected]: gianni.tw

    The products are manufactured under an ISO

    9 00 1 Q C 08 00 00 C er ti fi ed Q ua li tyManagement Program environment back i t sproduct quality, performance and commitmentto customer satisfaction.

    &

    GP001

    EM-NH2500DoubleStandardElectromagnetic Lock

    Optional Brackets

    The door swinging direction and the door frame header are used to determine whether the bracket is required and this identify is a

    measure of which brackets is suitable. Our optional brackets include L bracket LZ bracket- , - .

    With L-bracket for narrow door frames

    Magnet

    Arm atur e

    DoorFrame

    DoorLeaf

    60 mm

    A

    Out-swinging

    W he n < 6 0 m m , mu stinstalled with "L" brackets.

    "A "

    L-NH2500

    With LZ-bracket for in-swinging doors

    Operating Features

    EM-NH2500TD: Re-locking time delay

    Relocking Time Delay Switch ensures theautomatically turns to lock mode after thed oo r i s c lo se d p ro pe rl y a nd i t c an b eadjusted from 0 to 90 seconds.

    N.O.

    COM.

    N.C.

    PowerInput

    SPDT

    relay

    3A@12VDC

    Timer Adjust

    Shorten

    Trigger

    EM-NH2500M-BZ: BuzzerAlarm

    Door Held Open Alarm is an auditory feedback foruser. Alarm sounds when the door is not closed andhas exceeded a specified t ime l imit. Only way tos t op i s b y t h e u n c lo s in g d o or h a s b e e n c l o s edcorrectly. User can also configure alarm time limitsettings on the VR timer and it is adjustable from 0to 20 seconds.

    EM-NH2500M: Bond sensor output & Status LED

    Bond sensor is used to indicate the door status as

    i n a l oc ke d o r un lo ck ed co nd it ion . i s a

    visual feedback for user to give the true status ofthe lock at any time. Green light indicates the doori s i n se c ur e ( u nl o ck e d) a n d t h e R e d l i gh t i sindicates the door is secure (locked).

    Status LED

    Bond sensor monitor output : SPDT rated: 3A@12VDC

    Copyright 2008 Gianni industries, inc. All rights reserved.DM-CA-EM-NH2500 Ver. D Published on 2008.08.18