5
THE INTERNATIONAL JOURNAL FOR FIRE SAFETY PROFESSIONALS www.frmjournal.com MARCH 2017 MADE TO MEASURE Training matters Fit for purpose Enforcing the law

MADE TO MEASURE - Coltraco · FP030-SafetySigns-Ad.indd 1 13/07/2016 09:27 FRM_March17_Inners.indd 48 24/02/2017 17:46. Join FPA today for 15% discount thefpa.co.uk/signs | 01608

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MADE TO MEASURE - Coltraco · FP030-SafetySigns-Ad.indd 1 13/07/2016 09:27 FRM_March17_Inners.indd 48 24/02/2017 17:46. Join FPA today for 15% discount thefpa.co.uk/signs | 01608

THE INTERNATIONAL JOURNAL FOR FIRE SAFETY PROFESSIONALSwww.frmjournal.com MARCH 2017

MADE TO MEASURE Training mattersFit for purposeEnforcing the law

Fir

e R

isk

Ma

na

ge

me

nt

M

AR

CH

20

17

Page 2: MADE TO MEASURE - Coltraco · FP030-SafetySigns-Ad.indd 1 13/07/2016 09:27 FRM_March17_Inners.indd 48 24/02/2017 17:46. Join FPA today for 15% discount thefpa.co.uk/signs | 01608

46 MARCH 2017 www.frmjournal .com

IN ORDER to comply with regulations outlined in NFPA 2001 and ISO 14520, regular

room integrity tests have to be performed on rooms in which clean agent fire suppression systems are to be installed, to ensure the continued effectiveness of non sprinkler fire suppression.

Before installing clean agent fire suppression systems, which are used when sprinklers

Peak practiceFocusing on the last stage of regulatory testing, Dr Carl Hunter pinpoints key technology to locate potential leak sites in rooms with an insufficient gaseous extinguishing agent hold time

FRM_March17_Inners.indd 46 24/02/2017 17:46

Page 3: MADE TO MEASURE - Coltraco · FP030-SafetySigns-Ad.indd 1 13/07/2016 09:27 FRM_March17_Inners.indd 48 24/02/2017 17:46. Join FPA today for 15% discount thefpa.co.uk/signs | 01608

47www.frmjournal .com MARCH 2017

Current affairs

are inappropriate due to damaging enclosure contents, these regulatory tests must be undertaken in order to ensure the safety of the building structure and effectiveness of fire suppression.

A room integrity test is currently the most commonly used and universally accepted method of testing room integrity in preparation for the use of a clean agent (which could be

an inert gas or hydrocarbon). This uses fans to pressurise and depressurise the protected room, and determines the peak pressure and hold time necessary to ensure the effectiveness of these fire suppression systems.

Testing of this kind revolves around the establishment of the correct hold time and peak pressure necessary for the agent to be a successful extinguishant without damaging the enclosure or its contents. Currently, door fan testing is the primary method for making these calculations and for testing whether or not a room’s integrity is appropriate for clean agent discharge.

Regulatory compliance

As stated, the testing of room integrity is necessary for adherence to the standards and requirements outlined by NFPA 2001: Standard on Clean Agent Fire Extinguishing Systems and ISO 14520: Gaseous Fire-Extinguishing Systems, which were established concerning enclosure design and testing.

The success of clean agent fire suppression systems relies on holding the agent in the room for the correct amount of time, allowing for optimum agent concentration necessary to extinguish the fire. This is part of the total flooding principle on which inert gases and halocarbon agents function. Room integrity tests are imperative for the determination of both the hold time and the peak pressure needed for successful fire suppression.

In order to ensure that the correct agent concentration is achieved, the level of leakage is carefully monitored. Room integrity must be ‘tight’ enough to ensure sufficient retention time according to NFPA or ISO; yet remain ‘loose’ enough to prevent enclosure damage at discharge1. The presence of undesired and unregulated leak sites reduces room integrity and hence will dramatically impact the hold time and peak pressure, placing room

contents and potentially wall structures at risk.

Current testing

Both NFPA 2001 and ISO 14520 standards recommend using door fan testing to analyse the enclosure and retrieve the necessary values for hold time and peak pressure, and to measure the leakage of a room. The test uses large fans to pressurise the room in question by blowing air into it. Fan speed is adjusted to obtain flow pressure equivalent to the pressure exerted during a fire suppression system discharge, before reversing the fan to depressurise the room.

Airflow and pressure readings are then entered into a computer software program which calculates the equivalent leakage area (ELA) and subsequently the hold time and peak pressures. This method is a reputable and effective method of room integrity testing, and in recent years represents the one most respected.

However, a thesis by Todd Hetrick exposed the door fan integrity test as applicable for determining the total area of all leakages, but incapable of revealing the specific locations of leak sites2. Furthermore, the fan test room integrity testing kit itself is not only unable to provide specific leak locations, but also fails to provide any information concerning leak aperture. Given that most gaseous chemical agents used for fire suppression are heavier than air, the agent will begin to leak out of any lower level penetrations left unsealed, making their identification ever more important. In the case of too little leakage, vents must be created to reduce peak pressure in the event of agent discharge for fire suppression. In the case of too much leakage, unwanted leak sites need to be identified and sealed.

Despite its importance, it is the latter area of room integrity testing that has been comparatively neglected. Currently, puffer smoke devices have been created in order

FRM_March17_Inners.indd 47 24/02/2017 17:46

Page 4: MADE TO MEASURE - Coltraco · FP030-SafetySigns-Ad.indd 1 13/07/2016 09:27 FRM_March17_Inners.indd 48 24/02/2017 17:46. Join FPA today for 15% discount thefpa.co.uk/signs | 01608

48 MARCH 2017 www.frmjournal .com

Current affairs

to allow users to find leakage locations by following smoke pathways released in the protected room. However, these devices are time consuming and inaccurate.

Best solution

It is here that the value of Coltraco’s Portascanner Watertight Integrity Test Indicator is evident. This unit is a small, hand-held ultrasonic device featuring dual decibel and linear readings in the display. It is widely used in shipping, naval vessels, submarines and off shore oil and gas platforms. Moreover, the unit is supported by regional service stations in USA, UK, Dubai, India and Singapore.

Using ultrasonic technology, this device is able not only to pinpoint precise leak locations, but also to determine their leak apertures as small as 0.06mm with a tolerance of +/-0.02mm, making it by far the most accurate device for this function. The Portascanner 520 also provides an interpretation of the seal for desired locations, labelling them either water tight, weathertight or full leakage site, as appropriate.

The advantages of being able to accurately detect the

exact leak locations and size are self-evident when considered alongside the importance of reaching peak pressure for clean agent fire suppression to be eff ective. In a case where there is too much leakage in a room (and thus insuffi cient hold time), the Portascanner 520 is unrivalled for the rapid and accurate identifi cation of these sites, so that they can be sealed. It is lightweight, fast and easy to use, allowing leak site detection to increase its operational effi ciency and speed to a degree that has never been seen thus far in the fi re industry.

Fire industry first

As the most mathematically accurate device available, it provides precise data concerning leak locations and aperture, while its precision, non-invasive methodology and ease of use makes it the fi rst unit of its kind to be available to the fi re industry. It is perfectly positioned to work alongside door fan testing in order to meet the total requirements for fire safety regulations and to ensure the continuous fi re protection of rooms using clean agent fi re suppression systems.

Door fan testing has been proven to be a reliable and trusted method of room testing by industry experts, so it is expected that its dominance will continue in the near future. However, this type of testing has also been proven to be insuffi cient for leak site detection, as it calculates the overall area of leakage, without providing details on leak location or size.

This makes the process of leak sealing slow and could

fundamentally result in insuffi cient hold times being established. The immediate use of the Portascanner 520 lies in its improvement of the fi nal stage of room integrity testing – the search for leak sites in the case of a leakage excess – for which it can vastly improve accuracy and operational effi ciency.

In summary therefore, the Portascanner 520 is an exceptionally accurate and fast method for leak detection which is best used alongside door fan testing for a complete and comprehensive regulatory room test. It is the first of its kind, intuitive to use, non-invasive and highly accurate. As a consequence, it is of immediate use to the fi re industry

Dr Carl Hunter is CEO and MD of Coltraco Unltrasonics. For more information, view page 5

References1. Fire Stop Company (undated):

Total fl ooding clean agent enclosure integrity test, available at www.fi restop.com.pl/english/oferta/rozne/info_test_szczelnosci.html (accessed 27 May 2016).

2. Hetrick, TM (2009): Development and Validation of a Modifi ed Clean Agent Draining Model for Total Flooding Fire Suppression Systems, available at www.wpi.edu/Pubs/ETD/Available/etd-012109-095028/unrestricted/Thesis_Hetrick_Todd_2008_REV_01.pdf (accessed 27 May 2016).

small as 0.06mm with a tolerance

the most accurate device for this function. The Portascanner 520 also provides an interpretation of the seal for desired locations, labelling them either water tight, weathertight or

Join FPA today for

15% discount

thefpa.co.uk/signs | 01608 812 500

AAA Photoluminescent fire safety signs

• Over 3 times brighter than standard• At least 3 hours’ effective illumination• Mains power not required• No extra cost

Make the brighter choice.

What our customers say: “The service we get from the FPA is quick and efficient. The signs are of a high quality and... are no more costly than the cheaper alternatives that are available from mass suppliers.”

Eric Richardson, Head of Health and Safety, L&Q

FP030-SafetySigns-Ad.indd 1 13/07/2016 09:27FRM_March17_Inners.indd 48 24/02/2017 17:46

Page 5: MADE TO MEASURE - Coltraco · FP030-SafetySigns-Ad.indd 1 13/07/2016 09:27 FRM_March17_Inners.indd 48 24/02/2017 17:46. Join FPA today for 15% discount thefpa.co.uk/signs | 01608

Join FPA today for

15% discount

thefpa.co.uk/signs | 01608 812 500

AAA Photoluminescent fire safety signs

• Over 3 times brighter than standard• At least 3 hours’ effective illumination• Mains power not required• No extra cost

Make the brighter choice.

What our customers say: “The service we get from the FPA is quick and efficient. The signs are of a high quality and... are no more costly than the cheaper alternatives that are available from mass suppliers.”

Eric Richardson, Head of Health and Safety, L&Q

FP030-SafetySigns-Ad.indd 1 13/07/2016 09:27FRM_March17_Inners.indd 49 24/02/2017 17:46