Elba DualCast-iron, floor-standing boiler
Life-enhancing heat GB
C 1
46 -
02
MAdE IN ITAly
High quality Italian product
RELIABILITY
SAFETY
QUALITY
EASY TO OPERATE
Elba DualCast-iron, floor-standing boiler
ELBA DUAL
ELBA DUAL is an innovative range of floor-standing boilers,
designed and manufactured by Fondital. Having thermal
outputs ranging from 24 to 73 kW, ELBA DUAL can be
equipped with oil-or gas-fired blown burners.
The heat exchanger with three flue gas passes is made of
cast-iron (EN-GJL-200). The combustion chamber is
engineered for the flame to fully develop and reach a wide
exchange area, which absorbs high heat while keeping the
superficial thermal load on its walls low. The three flue gas
passes, the high efficiency combustion chamber with wet
bottom, and the flue gas passes profiles, which optimize the
heat exchange, allow ELBA DUAL to be classified among
high-efficiency heat generators.
The heat exchanger is fully insulated by a high-thickness,
glass-wool layer, avoiding cost-affecting heat losses.
The casing is manufactured with electro-zinc plated metal
sheet, finished by epoxy-polyester powder paint for longer
lasting life time.
The control panel includes CH temperature selector (49°C/82°C range), thermometer, power on switch with light, manual reset safety thermostat, and lights indicating pump and burner operation and overheating shutdown.Behind the control panel door, space is provided for installation of optional equipment such as a thermoregulation control unit or a programmable timer.
ELBA DUAL Floor-standing boiler designed for domestic heating
• Cast-ironexchangerwiththreefluegaspasses.
• Oil-orgas-firedblownburneroperation.
• Extra-thickinsulationlayerpreventingheatlosses.
• ControlandmanagementpanelequippedwithWIELANDtype cable to the burner, CH pump control, ready for connection to room thermostat and water pressure switch.
• Electro-zincplatedmetal sheet,epoxy-polyesterpowderpaint finish casing.
• Efficiencyratingaccordingto92/42/CEE:★★
A dedicated interface printed circuit board allows all models to be coupled with free-standing water heaters.Fondital also designs and manufactures a 120 liter, stainless steel, free-standing water tank (model WHPF BO) which can withstand the weight of Elba Dual 23, 33, and 43 models.
Life-enhancing heat
Elba DualCast-iron, floor-standing boiler
Item Description Code
Electric kit for managementof 3 CH zones
0KITPOMZ00
Electric kit for connectionto external water heater
0KITBEST06
Hydraulic kit for connection to WHPF BO horizontal
water heater0KITPOVA03
Pump and expansion vessel(12 litre) kit, with manometer,pressure switch, safety valve
0KITPOVA04
Hydraulic kit for connectionto WHPF BO horizontal
water heater + pump and expansion vessel
0KITPOVA05
Thermoregulationcontrol unit kit
0KITCEEL02
Remote control for thermoregulation control unit
(temperature adjustment)0CREMOTO00
Remote control for thermoregulation control unit
(all functions)0CREMOTO01
Daily timer kit 0KITBEST04
Weekly timer kit 0KITBEST05
ACCESSORIES
DIMENSIONS
Model L M R
23 400 G11/4 G 1
33 525 G11/4 G 1
43 625 G11/4 G 1
53 700 G11/4 G 1
63 800 G11/4 G 1
73 900 G11/4 G 1
M CH flowR CH return
Elba Dual boilers can be coupled with Pyrós burners by Fondital, as described in the chart below:
Oil-fired burners:
ELBA DUAL BURNER MODEL
ELBA DUAL 23 PYRÓS DUAL 1 GTFR 3
ELBA DUAL 33 PYRÓS DUAL 1 GTFR 4
ELBA DUAL 43 PYRÓS DUAL 1 GTF 5
ELBA DUAL 53 PYRÓS 1 GTF 6
ELBA DUAL 63 PYRÓS 1 GTF 7
ELBA DUAL 73 PYRÓS 1 GTF 8
Gas-fired:
ELBA DUAL BURNER MODEL GAS TRAIN MODEL Min. PRESSURE (mbar)
ELBA DUAL 23 - - -
ELBA DUAL 33 PYRÓS 1 MTF 50MB - DLE 403 9
MB - DLE 405 7
ELBA DUAL 43 PYRÓS 1 MTF 50 MB - DLE 405 7
ELBA DUAL 53 PYRÓS 1 MTF 100MB - DLE 405 10
MB - DLE 407 8
ELBA DUAL 63 PYRÓS 1 MTF 100MB - DLE 405 10
MB - DLE 407 8
ELBA DUAL 73 PYRÓS 1 MTF 100MB - DLE 405 12
MB - DLE 407 10
PYRÓS 1 MTFPYRÓS DUAL 1 GTFR
Life-enhancing heat
FONDITAL S.p.A.
25078 VESTONE (Brescia) Italy - Via Mocenigo, 123
Tel. +39 0365 878.31 - Fax +39 0365 820.200
e-mail: [email protected] - www.fondital.it
Uff.
Pub
. Fon
dita
l - C
TC 0
3 C
146
- 0
2 A
pril
e 20
08 (2
.000
- 0
3/20
08)
9PC
GB
03C
146
The
man
ufac
ture
r re
serv
es th
e rig
ht to
impl
emen
t mod
ifica
tions
with
out n
otice
.
TECHNICAL DATA
MODEL 23 33 43 53 63 73CE efficiency rating ★★ ★★ ★★ ★★ ★★ ★★
Installation type B23
Nominal input (Qn) kW 26.6 36.3 47.2 57.9 68.5 79.3
Nominal output (Pn) kW 24 33 43 53 63 73
Nominal load efficiency % 90 91 91 91.5 92 92
Reduced load efficiency (30%) % 89.7 90.7 90.7 91.1 91.6 91.6
No. of elements of heat exchanger 3 4 5 6 7 8
CH temperature range °C 49-82 49-82 49-82 49-82 49-82 49-82
Water content l 15.5 19.5 23.5 27.5 31.5 35.5
Min. water flow rate l/h 680 950 1230 1520 1800 2150
Combustion chamber length mm 208 308 408 508 608 708
Flue gas termperature °C 210 190 188 202 181 175
Flue gas flow rate Kg/h 40 53.2 69.3 83.1 97.7 114.5
Working pressure Bar 4 4 4 4 4 4
Flue gas side load loss at max. thermal input Pa 13 25 40 40 50 65
Water side load loss 10° ΔT Pa 4800 5600 6000 7100 10000 11200
Temperature holding loss at ΔT =50° % 0.3 0.3 0.3 0.3 0.3 0.3
Burner head max. diameter mm 110 110 110 110 110 110
Flue gas discharge diameter mm 150 150 150 150 150 150
Power tension V 230 230 230 230 230 230
Frequency Hz 50 50 50 50 50 50
Fuse A 4 4 4 4 4 4
Electric protection class - IP40 IP40 IP40 IP40 IP40 IP40
Recommended nozzle for oil-fired blown burner
Brand Delavan W – Steinen Q – Danfoss S
Flow rate Usgal/h 0.65 0.75 1.00 1.10 1.35 1.65
Angle/cone 60°W 60°B
Fuel type C02 content
Natural gas G20 9÷9.7
Butane gas G30 10.7÷11.6
Propane gas G31 10.5÷11.4
Oil 12.5÷13
CAST-IRON, FLOOR-STANDING BOILER