2
Technical Information machine-dro.co.uk +44 (0)1992 450780 www.machine-dro.co.uk - Allendale Electronics Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ. Images & Content ©2010 Allendale Electronics Limited. E&OE - Specifications subject to change without prior notice. DIGITAL READOUTS ® 1 OF 2 Machine Tool Linear Encoder Selection Guide Standard Measurements Doc V: 1.0 Mill Travel Measuring Guide STEP 4. Measure between the two marks, this will give the travel of the slide. Repeat these steps for each axis. STEP 1. Adjust all stops to the most outward position. Traverse the table to its full extent in one direction. STEP 2. Draw a line across the table and lower slide. STEP 3. Traverse the table to its full extent in the opposite direction. On smaller milling tables the maximum height from the Y axis slide to the top of the table also needs to be measured. The minimum distance between the rear of the table and column. Depending upon available space it may be necessary to select a slim profile scale or mount on the front of the table. The overall length of table & gap between any table drains. To ensure the scale is easier to fit on the machine. Measure maximum length scale that can be fitted on each axis. Additional Measurements Machine Make... Machine Model... X Travel... Y Travel... Z Travel... Notes... (E.g Adcock And Shipley) (E.g Bridgeport) (E.g Longitudinal Travel 762mm) (E.g Cross Travel 302mm) (E.g Knee Travel 406mm)

Machine Tool Linear Encoder Selection Guide › pub › media › downloads › ... · lower slide. STEP 3. Traverse the table to its full extent in the opposite direction. On smaller

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Machine Tool Linear Encoder Selection Guide › pub › media › downloads › ... · lower slide. STEP 3. Traverse the table to its full extent in the opposite direction. On smaller

Technical Information

mac

hine

-dro

.co.

uk +

44 (

0)19

92 4

5078

0

www.machine-dro.co.uk - Allendale Electronics Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.Images & Content ©2010 Allendale Electronics Limited. E&OE - Specifi cations subject to change without prior notice.

DIGITAL READOUTS

®

1 OF 2

Mac

hine

Too

l Lin

ear

Enc

oder

Sel

ecti

on G

uide

Standard Measurements

Doc V: 1.0Mill Travel Measuring Guide

STEP 4. Measure between the two marks, this will give the travel of the slide. Repeat these steps for each axis.

STEP 1. Adjust all stops to the most outward position. Traverse the table to its full extent in one direction.

STEP 2. Draw a line across the table and lower slide.

STEP 3. Traverse the table to its full extent in the opposite direction.

On smaller milling tables the maximum height from the Y axis slide to the top of the table also needs to be measured.

The minimum distance between the rear of the table and column. Depending upon available space it may be necessary to select a slim profile scale or mount on the front of the table.

The overall length of table & gap between any table drains. To ensure the scale is easier to fit on the machine. Measure maximum length scale that can be fitted on each axis.

Additional Measurements

Machine Make...

Machine Model...

X Travel...

Y Travel...

Z Travel...

Notes...

(E.g Adcock And Shipley)

(E.g Bridgeport)

(E.g Longitudinal Travel 762mm)

(E.g Cross Travel 302mm)

(E.g Knee Travel 406mm)

Page 2: Machine Tool Linear Encoder Selection Guide › pub › media › downloads › ... · lower slide. STEP 3. Traverse the table to its full extent in the opposite direction. On smaller

Technical Information

mac

hine

-dro

.co.

uk +

44 (

0)19

92 4

5078

0

www.machine-dro.co.uk - Allendale Electronics Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.Images & Content ©2010 Allendale Electronics Limited. E&OE - Specifi cations subject to change without prior notice.

DIGITAL READOUTS

®

2 OF 2

Mac

hine

Too

l Lin

ear

Enc

oder

Sel

ecti

on G

uide

Doc V: 1.0Lathe Travel Measuring Guide

STEP 3. Push the tail stock out to its most outward position. Traverse the carriage to its full extent toward the tail stock.

STEP 1. Adjust all stops to the most outward position. Traverse the saddle to it maximum travel towards the chuck.

STEP 2. Draw a line along the edge of the carriage on the bed.

STEP 4. Measure between the mark and the edge of the carriage. This will give you the carriage travel.

STEP 1. Traverse the cross slide to its most outward position. Draw a line across the cross slide and lower slide.

STEP 2. Traverse the cross slide to its most inward position. Measure between the two marks, this will give the travel of the cross slide.

Other measurements include the width of the gap between the bed. The overall height from the top of the cross slide to the base of the slide.

Some lathes have a recessed cross slide, by measuring the gap we may be able to use a slim profile scale to fit within the slot.

Standard Measurements

Additional Measurements

Machine Make...

Machine Model...

X Travel...

Z Travel...

Top Slide Travel...

Notes...

(E.g Colchester)

(E.g Triumph 2000)

(E.g Carridge Travel 760mm)

(E.g Cross Slide Travel 228mm)

(E.g Top Slide Travel 100mm)