8
used in: - - - - - - - - - microelectronics - - - - - - - - - medical device - - - - - - - - - semiconductor - - - - - - - - - disk drive - - - - - - - - - laboratory - - - - - - - - - pharmaceutical markets - - - - - - - - - hospitals - - - - - - - - - clean rooms MAC 10 ® LE-DC 4x4 FAMILY OF FAN FILTER UNITS

MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT

used in:- - - - - - - - -microelectronics- - - - - - - - -medical device- - - - - - - - - semiconductor- - - - - - - - - disk drive- - - - - - - - - laboratory- - - - - - - - - pharmaceuticalmarkets- - - - - - - - - hospitals- - - - - - - - -clean rooms

MAC 10® LE-DC 4x4F A M I L Y O F F A N F I L T E R U N I T S

Page 2: MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT

Clean air solutions built for you. M O R E I N F O R M A T I O N A V A I L A B L E A T W W W . E N V I R C O - E M E A . C O M

Page 3: MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT

www.envirco-emea.com | Innovators in Clean Air Technology 3

Cop

yrig

ht ©

2012

Env

irco

MAC 10® LE-DC 4x4

■ MAC 10® LE-DC 4x4 IntroductionThe MAC 10® is designed for the most challenging cleanroom applications. It offers significant cost savings and electrical efficiencies for large cleanrooms. The MAC 10® LE-DC 4x4 maximizes energy efficiencies with its exclusive backward blower wheel design. It provides 0.45m/s airflow and up to 250Pa of ESP (External Static Pressure) capability in clean un-loaded conditions, enabling cleanroom projects to operate cost effectively.

Fewer components mean lower installed costs. With the use of the MAC 10® LE-DC 4x4 unit, additional savings are captured in the ceiling plenum because less grid is required and fewer electrical connections are needed. Even better, this model also provides a lower sound level than most competitive 600mm x 1,210mm fan filter units.

■ Standard Features » Low sound, low watts, low profile and low operating costs. » Energy efficient DC motor (1/2hp / 0.37kW). » Universal Controller allows the following.

- Manual control via the integral potentiometer. - Remote speed control via 0-10V analogue signal. - Network control via ModBus® compatible RTU network protocol.

» High Efficiency Particulate Air (HEPA) filter, 99.99% efficient at 0.3 micron particle size (H13). » 250Pa of external static pressure capability at 0.45m/s with HEPA (H13) filter in clean un-loaded conditions. » Aluminium construction with a mill finish for durability. » 230V CE marked. » Protective inlet ring.

■ Options » Ultra Low Penetration Air (ULPA) filter - 99.9995% efficient at 0.12 micron particle size (U15) and U16 filters available. » Monitoring and Control System – A range of Console and PLC options are available for stand-alone or integrated BMS

network control solutions. » The exterior is available powder-coated. » Room-Side Replacement (RSR) available with gel seal filter. The filter is replaced from the roomside. » RSRE provides filter and motor/blower assembly replacement from the roomside.

■ Warranty » Limited 1-year warranty.

MAC 10® LE-DC 4x4

Page 4: MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT

4 Innovators in Clean Air Technology | www.envirco-emea.com

Copyright ©

2012 Envirco

MAC 10® LE-DC 4x4

■ SpecificationsConstructionWelded aluminium cabinet.

FiltersAluminium framed High Efficiency Particulate Air (HEPA) type, with a minimum efficiency of 99.99% @ 0.3 micron (H13) aerosol challenged (zero probed). H14, U15 and U16 filters can be supplied upon request.

Motor/Blower AssemblyDirect drive, continuous duty 1/2 Hp (0.37kW) EC motor with sealed-for-life bearings and inherent overload protection. The blower assembly is electronically (dynamically) balanced and is designed to provide rated airflow through a 50% increase in initial static pressure.

■ Performance 4x4 Standard, RSR, & RSRENOMINAL UNIT SIZE MAX m/h WATTS @ 0.45m/s UNIT WEIGHT (kg)

Standard 3,315 105 61.23RSR & RSRE 3,230 115 68.04

NOTES: Test data is taken with a vane anemometer at 0.45m/s in clean un-loaded conditions (0Pa ESP).Full Load Current; 230V, 50Hz, 1 Ph = 3.2A.The initial current exceeds 3.2A momentarily; suitable circuit breakers should be installed.

■ Dimensions

ON/OFF SWITCH

7/8Ø (22.23mm)KNOCKOUT FOR INCOMING POWER

UNIVERSAL CONTROL

46.655” (1,185mm)PLENUM - TYPICAL10.679”

(271.25mm)

UNIVERSALCONTROLLER

POWER ENTRY10.679” (271.25mm)

10.679”(271.25mm)

ON/OFFSWITCH

47.625” (1,209.68mm)FILTER - TYPICAL

47.83” (1,214.88mm)PLENUM FLANGE - TYPICAL

46.86” (1,190.24mm)LID PANEL - TYPICAL

44.22” (1,123.19mm) (20) 1/4” THREADED INSERTS - TYPICAL

3.752”(95.30mm)

17.632”(447.85mm)

Top & Side ViewsSide and Angled Views

Page 5: MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT

www.envirco-emea.com | Innovators in Clean Air Technology 5

Cop

yrig

ht ©

2012

Env

irco

Performance

■ Performance ChartsMAC 10 LEDC 4x4 STD HEPA

0.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

90.00

100.00

0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95Velocity (M/s)

% P

WM

(Pul

se W

idth

Mod

ulat

ion

Sign

al)

150175200225250 0Esp

255075100125

MAC 10 LEDC 4x4 STD HEPA

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

500.00

550.00

600.00

0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95Velocity (M/s)

Pow

er (W

atts

)

150175200225250 0 PaEsp

255075100125

Testing performed in accordance with IEST Recommended Practices IEST-RP-CC006.3 Includes initial clean filter pressure losses. Active Filter Face Area* = 1.33 m2.% PWM = Motor Controller Pulse Width Modulation Signal

Unit Operating Amps = Watts / (Volts x Power Factor) Power Factor

@ 20% PWM = 0.61 @ 40% PWM = 0.67 @ 60% PWM = 0.71 @ 80% PWM = 0.74 @ 100% PWM = 0.74

Sensible Heat Gain: Total Heat Method - Btu/hr = 3.431 x Motor Watts Motor Efficiency Method = Btu/hr = 3.431 x .35 x Motor Watts

*Active filter face area does not include area losses due to protective screens. **Due to variations in filter protective screens, actual values measured 152 mm from filter face in accordance with IEST Standards, may vary from charted values.

MAC 10 LEDC 4x4 STD HEPA

0.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

90.00

100.00

0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95Velocity (M/s)

% P

WM

(Pul

se W

idth

Mod

ulat

ion

Sign

al)

150175200225250 0Esp

255075100125

MAC 10 LEDC 4x4 STD HEPA

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

500.00

550.00

600.00

0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95Velocity (M/s)

Pow

er (W

atts

)

150175200225250 0 PaEsp

255075100125

Testing performed in accordance with IEST Recommended Practices IEST-RP-CC006.3 Includes initial clean filter pressure losses. Active Filter Face Area* = 1.33 m2.% PWM = Motor Controller Pulse Width Modulation Signal

Unit Operating Amps = Watts / (Volts x Power Factor) Power Factor

@ 20% PWM = 0.61 @ 40% PWM = 0.67 @ 60% PWM = 0.71 @ 80% PWM = 0.74 @ 100% PWM = 0.74

Sensible Heat Gain: Total Heat Method - Btu/hr = 3.431 x Motor Watts Motor Efficiency Method = Btu/hr = 3.431 x .35 x Motor Watts

*Active filter face area does not include area losses due to protective screens. **Due to variations in filter protective screens, actual values measured 152 mm from filter face in accordance with IEST Standards, may vary from charted values.

Test data taken with a vane anemometer.Testing performed in accordance with IEST Recommended Practices IEST-RP-CC006.3Includes initial clean filter pressure losses.Active Filter Face Area* = 1.33 m2.% PWM = Motor Controller Pulse Width Modulation Signal

Unit Operating Amps = Watts / (Volts x Power Factor)Power Factor@ 20% PWM = 0.61@ 40% PWM = 0.67@ 60% PWM = 0.71@ 80% PWM = 0.74@ 100% PWM = 0.74

Sensible Heat Gain:Total Heat Method - Btu/hr = 3.431 x Motor WattsMotor Efficiency Method = Btu/hr = 3.431 x .35 x Motor Watts

*Active filter face area does not include area losses due to protective screens.**Due to variations in filter protective screens, actual values measured 152mm from filter face in accordance with IEST Standards, mayvary from charted values.

MAC 10 LE-DC 4x4 STD HEPA (H13)

Page 6: MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT

6 Innovators in Clean Air Technology | www.envirco-emea.com

Copyright ©

2012 Envirco

Performance

■ Performance ChartsMAC 10 LEDC 4x4 RSR HEPA

0.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

90.00

100.00

0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95Velocity (M/s)

% P

WM

(Pul

se W

idth

Mod

ulat

ion

Sign

al)

150175200225250 0 PaEsp

255075100125

MAC 10 LEDC 4x4 RSR HEPA

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

500.00

550.00

600.00

650.00

0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95Velocity (M/s)

Pow

er (W

atts

)

150175200225250 0 PaEsp

255075100125

Testing performed in accordance with IEST Recommended Practices IEST-RP-CC006.3 Includes initial clean filter pressure losses. Active Filter Face Area* = 1.13 m2.% PWM = Motor Controller Pulse Width Modulation Signal

Unit Operating Amps = Watts / (Volts x Power Factor) Power Factor

@ 20% PWM = 0.41 @ 40% PWM = 0.46 @ 60% PWM = 0.49 @ 80% PWM = 0.51 @ 100% PWM = 0.52

Sensible Heat Gain: Total Heat Method - Btu/hr = 3.431 x Motor Watts Motor Efficiency Method = Btu/hr = 3.431 x .35 x Motor Watts

*Active filter face area does not include area losses due to protective screens. **Due to variations in filter protective screens, actual values measured 152 mm from filter face in accordance with IEST Standards, may vary from charted values.

MAC 10 LEDC 4x4 RSR HEPA

0.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

90.00

100.00

0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95Velocity (M/s)

% P

WM

(Pul

se W

idth

Mod

ulat

ion

Sign

al)

150175200225250 0 PaEsp

255075100125

MAC 10 LEDC 4x4 RSR HEPA

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

500.00

550.00

600.00

650.00

0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95Velocity (M/s)

Pow

er (W

atts

)

150175200225250 0 PaEsp

255075100125

Testing performed in accordance with IEST Recommended Practices IEST-RP-CC006.3 Includes initial clean filter pressure losses. Active Filter Face Area* = 1.13 m2.% PWM = Motor Controller Pulse Width Modulation Signal

Unit Operating Amps = Watts / (Volts x Power Factor) Power Factor

@ 20% PWM = 0.41 @ 40% PWM = 0.46 @ 60% PWM = 0.49 @ 80% PWM = 0.51 @ 100% PWM = 0.52

Sensible Heat Gain: Total Heat Method - Btu/hr = 3.431 x Motor Watts Motor Efficiency Method = Btu/hr = 3.431 x .35 x Motor Watts

*Active filter face area does not include area losses due to protective screens. **Due to variations in filter protective screens, actual values measured 152 mm from filter face in accordance with IEST Standards, may vary from charted values.

Test data taken with a vane anemometer.Testing performed in accordance with IEST Recommended Practices IEST-RP-CC006.3Includes initial clean filter pressure losses.Active Filter Face Area* = 1.33 m2.% PWM = Motor Controller Pulse Width Modulation Signal

Unit Operating Amps = Watts / (Volts x Power Factor)Power Factor@ 20% PWM = 0.61@ 40% PWM = 0.67@ 60% PWM = 0.71@ 80% PWM = 0.74@ 100% PWM = 0.74

Sensible Heat Gain:Total Heat Method - Btu/hr = 3.431 x Motor WattsMotor Efficiency Method = Btu/hr = 3.431 x .35 x Motor Watts

*Active filter face area does not include area losses due to protective screens.**Due to variations in filter protective screens, actual values measured 152mm from filter face in accordance with IEST Standards, mayvary from charted values.

MAC 10 LE-DC 4x4 RSR HEPA (H13)

Page 7: MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT
Page 8: MAC 10 LE-DC 4x4 · Clean air solutions built for you. MORE INFORMATION AVAILABLE AT

Envirco® MAC 10® and VE5 are registered trademarks of Envirco®, USA. Specifications subject to modifications or changes without notice. US patents 4,560,395 and 5,470,363. Other patents issued and pending in foreign countries. Special thanks to Connect2Cleanrooms for cleanroom photography.

Clean air solutions built for you. M O R E I N F O R M A T I O N A V A I L A B L E A T W W W . E N V I R C O - E M E A . C O M

MAC10-LEDC4X4/1012 | Copyright ©2012 Envirco®. All Rights Reserved.

Provided by Your Local Envirco® Representative:

Envirco® Europe, Middle East and AfricaThe Cavendish Centre, Winnall Close | Winchester, Hampshire; S023 OLB, UK

tel:+44(0)1962.840465 | fax:+44(0)1962.828619www.envirco-emea.com | email: [email protected]

Industrial Cleanroom Products

» MAC 10® Original

» MAC 10® IQ™

» Ducted Ceiling Module (DCM)

» AC or DC Control Systems

Hospital & HealthcareHospital & Healthcare

» IsoClean® and IsoClean with Ultraviolet Light

» IsoClean® CM

» AirCeil®