1
1999 SPECIFICATIONS ALL DIMENSIONS ON THIS SHEET IN MILLIMETERS UNLESS OTHERWISE NOTED. R-112M ROADWAY STANDARD ( METRIC ) OKLAHOMA DEPT. OF TRANSPORTATION DESCRIPTION DATE REVISIONS 7/99 ITEM NO. BASIS OF PAYMENT UNIT CLEAR FROM GROUND LINE IN LOCATIONS APPROVED BY THE ENGINEER. ALTERNATE CLIMB BARRIERS APPROVED BY THE ENGINEER PRIOR TO INSTALLATION MAY BE USED. FENCE POST EXTENSION ARM SHALL BE MADE OF PRESSED STEEL OR MALLEABLE IRON AND SHALL BE GALVANIZED AFTER FABRICATION. WIDTHS. NO FABRIC WITH TWISTS AND BARBS ON BOTH SELVAGES WILL BE ACCEPTED. CONNECTION STRETCHER POSTS SHALL BE EMBEDDED IN CONCRETE WHEN FENCE IS BEING ERECTED ON EARTHEN FOUNDATIONS. OTHER POSTS MAY BE EMBEDDED IN CONCRETE IF AND AS DIRECTED BY THE ENGINEER TO SATISFY SPECIFIC 624.06( D 624.06( E FENCE - STYLE CLF GATES - STYLE CLF EACH MAXIMUM LINE POST TENSION WIRE LINE POST SEE GENERAL NOTES TIE WIRES SEE DETAIL ALTERNATE CONC. FOOTING TO BE USED IF AND WHERE DIRECTED BY THE ENGINEER POST BRACE RAIL TYPICAL LINE POST DETAIL TOP RAIL TOP RAIL POST BRACE RAIL TIE WIRES AT STRETCHER STRETCHER POST BANDS END, CORNER, OR SEE POST & FRAMEWORK SCHEDULE FOR FOOTING DIMENSIONS. CONCRETE FOOTING CAP END, CORNER, & STRETCHER DETAILS USE STRETCHER DETAILS AT ALL CORNERS, BENDS IN R/W, ON HILLTOPS, VARIABLE VARIABLE TOP RAIL GATE POST STRETCHER BANDS SEE GENERAL NOTES SEE POST & FRAMEWORK SCHEDULE FOR FOOTING DIMENSIONS. VARIABLE CAP 6.0 m MAXIMUM ( SINGLE GATE) CAP END POST TURNBUCKLES TOP & BOTTOM RAIL. TIE WIRES AT STRETCHER BARS SEE PLANS FOR SIZE AND LOCATION OF GATES. WHERE GATE DETAIL LINE POST TIE WIRES SEE DETAIL SEE GENERAL NOTES END POST CORNER POST GATE STRETCHER POST FAN RIGHT-OF -WAY FENCE CONCRETE FOOTING FOR POSTS SEE PLAN AND PROFILE SHEETS FOR LOCATION. FENCING SYMBOLS ON PLANS FENCING SYMBOL THIS SHEET VARIABLE VARIABLE LINE POST FAN POST FAN POST TIE WIRES SEE DETAIL VARIABLE LINE POST LINE POST TENSION WIRE TENSION WIRE TOP & BOTTOM TOP & BOTTOM SEE PLANS FOR APPROX. LOCATION OF FANS. ANGLE TO BE PLACED FAN DETAILS FAN POST LINE POST TIE WIRES SEE DETAIL VARIABLE SEE END DETAIL 45 SUGGESTED ANGLE. ACTUAL ANGLE AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER. SEE CORNER DETAIL SEE END DETAIL BRACE BAND GENERAL NOTES ELEVATION CULVERT CONNECTION PLAN FASTNER ( NOM. ) SECTION A-A VARIABLE APPROX. MAX. MAX. A A 45 EXTENSION ARM DETAIL EXTENSION ARM SEE DETAIL INSIDE OR OUTSIDE CONNECTION MAY BE USED. EXTENSION ARMS SHALL BE FITTED WITH WIRE CLIPS OR HOOKED NOTCHES TO HOLD APPROVED BY THE ENGINEER. ANGULAR CLIMB BARRIER FOR LINE POSTS VERTICAL CLIMB BARRIER FOR END & GATE POSTS DOUBLE GATE LATCH MAX. MAX. MAX. C E B A D F A B C D LOCK KEEPER LOCK KEEPER GUIDE LOWER FORKS UPPER FORKS E F LOWER GUIDE UPPER GUIDE A B ALTERNATE TYPE LATCH MAY BE USED IF APPROVED BY THE ENGINEER. TYPICAL GATE LATCH DETAIL SINGLE GATE LATCH LINE POST TIE WIRE WRAPPED 2 TURNS MIN. EACH SIDE OF POST TIE WIRE DETAIL WIRE FABRIC TO BE WOVEN INTO LOCK LOOPS FOR THE ENTIRE WIDTH OF THE FABRIC. AS SHOWN ON PLANS AS SHOWN ON PLANS FOOTING REQUIREMENTS. IN PRICE BID FOR CHAIN LINK FENCE. 2 VERTICAL BRACES AT 1/3 POINTS. ON PLANS AS SHOWN BRACE BAND LATCH GATE BRACE RAIL POST GATE HINGES TENSION WIRES A A 45 ALTERNATE DETAIL EXTEN. ARM WRAPPED 2 WRAPS ( MIN. ) TOP RAIL MAY BE USED IN LIEU LINE POST CLIPPED AT APPROVED BY THE ENGINEER. OF BARBED TOP WIRE, IF WHEN TOP RAIL IS USED IN LIEU OF BARBED TOP WIRE THE COST OF TOP RAIL SHALL BE INCLUDED IN THE PRICE BID FOR FENCE. IN VALLEYS OR DEEP DEPRESSIONS AND AT 150 METERS MAXIMUM SPACING. 600 mm C/C 600 mm C/C VALLEYS AND AT A MAXIMUM OF 150 m APART. A, B OR C A, B or C A, B or C AS SHOWN ON PLANS A, B OR C 80 80 150 150 80 140 140 50 80 350 ( MIN. ) 140 140 50 ) ) 965 100 80 80 150 80 80 80 100 100 50 150 80 80 80 80 1. ALL CONSTRUCTION AND MATERIAL REQUIREMENTS SHALL BE IN ACCORDANCE 4. ALL MISCELLANEOUS HARDWARE SHALL BE FURNISHED GALVANIZED OR 5. CLIMB BARRIER SHOWN INTENDED ONLY TO SHOW AN ACCEPTABLE TYPE. 6. CHAIN LINK FABRIC MAY BE ACCEPTED KNUCKLED BOTH SELVAGES IN ALL 7. STRETCHER POSTS TO BE USED IN GENERAL AT HILL TOPS AND AT BOTTOM OF 8. ALL POSTS WITH THE EXCEPTION OF LINE POSTS, FAN POSTS AND HEADWALL 150 CLIPPED AT 300 mm C/C STRETCHER BARS TRUSS RODS 10 mm TIE WIRES AT 600 mm C/C TRUSS ROD 10 mm 5 mm x 19 mm BRACE BAND w/10 mm BOLT TOP & BOTTOM TENSION WIRES CLIPPED AT AT 600 mm C/C NOTE: GATES WIDER THAN 3.6 m REQUIRE DOUBLE SWING GATES WITH MIDDLE LATCH. WIDTH GREATER THAN 6.0 m IS REQUIRED, USE 3.6 m ( MAX.) 3.6 m ( MAX.) 3.6 m ( MAX.) 3.6 m ( MAX.) 3.6 m ( MAX.) ( MAX.) ( MAX.) 50 mm CLIPPED AT 300 mm c/c CLIPPED AT 300 mm c/c APRX. 25 mm 10 mm TRUSS ROD 5 mm x 19 mm TRUSS ROD 10 mm LINE POST TOP RAIL 932.16 OF TOP RAIL, INCLUDING ALL HARDWARE FOR INSTALLATION, SHALL BRACE BAND W/10 mm BOLT BRACE BAND W/10 mm BOLT W/10 mm BOLT W/10 mm BOLT BE PAID FOR AS TOP RAIL, BY THE LINEAR METER, AS INSTALLED. 3.6 m 2.4 m 2.4 m 2.4 m 2.4 m 200 22 FOR EACH METER OF FENCE HEIGHT LESS THAN 2 METERS HIGH. "X" "X" STRETCHER SECTION AS SHOWN SEE TABLE FOR CHORD LENGTH C LENGTH STRETCHER SECTION AS SHOWN R/W SEE TABLE FOR CHORD LENGTH C LENGTH RADIUS SPACING FOR STRETCHER SECTION TYPICAL PLACEMENT FOR CURVES 300 300 SPACING FROM R/W TO FENCE "X" mm 1600 1400 1200 1000 800 600 590 500 450 400 350 300 290 250 200 370 380 395 410 440 485 375 390 400 415 430 450 360 370 385 CURVE RADIUS OVER 1600 m CHORD LENGTH 600 m TO 1600 m 29.8 m 19.0 m 11.8 m LESS THAN 300 m STD. FENCE 590 m 300 m TO RIGHT - OF - WAY FENCE STYLE - CLF ( CHAIN LINK FENCE ) RWF3-1 SHAPE DIMENSIONS CRITICAL AXIS SEC. MODULUS NOMENCLATURE WEIGHT LENGTH FOR GIVEN FENCE FAB. HT EMBEDMENT FOR GIVEN FENCE FAB. HT A B C FOOTING DIM. IN EARTH FOOTING DIM. IN ROCK LINE POST PIPE ROLL ROLL FORMED FORMED "H" RAIL 4.05 43mm 43mm 3.93 2.75 4.85 STAND. "C" HEAVY "C" POST & FRAMEWORK SCHEDULE PIPE 88mm x ROLL FORMED PIPE PIPE PIPE 102mmO.D. END, CORNER, OR STRETCHER POSTS & LESS GATE POSTS TOP RAIL OR GATE FRAMES POST BRACE RAIL 2.0mWIDE GATES UP TO GATES 2.1m GATES 4.1m PIPE PIPE PIPE PIPE ROLL FORMED 1.91mmTHK. 13.55 7.22 5.43 48mmO.D. 57mm x 48mm x 42mm 57mm x 60mmO.D. 73mmO.D. 141mmO.D. 42mmO.D. 2.1m TO 4.1m TO TO 4.0m TO 6.0m 42mmO.D. 48mmO.D. 48mmO.D. 3.21 2.69 2.00 2.69 21.75 8.62 225mmDIA. 100mmDIA. 225mmDIA. 150mmDIA. 125mmDIA. 150mmDIA. 200mmDIA. 355mmDIA. 304mmDIA. 2.083m W/CONC. FOOTING; 2.235m IF DRIVEN. 2.464m W/CONC. FOOTING; 2.616m IF DRIVEN. 2.845m W/CONC. FOOTING; 3.000m IF DRIVEN. 600mm IN CONC. FOOTING; 500mm IF DRIVEN. 675mm IN CONC. FOOTING; 500mm IF DRIVEN. 750mm IN CONC. FOOTING; 900mm IF DRIVEN. A B C 5.39 5.02 6.03 9.18 39.17 89.33 3.20 2.70 4.43 5.34 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 cm 3 ( kg/m ) 4.02 41mm I. D. 42mm I. D. 37mm 37mm I. D. I. D. 128mm 14mm 63mm I. D. I. D. I. D. 900 mm 990 mm 1050 mm 38 mm 127 mm 38 mm 88 mm 32 mm 32 mm 63 mm 50 mm 38 mm 225 mm DIA. 100 mm DIA. 225 mm DEEP 2.235 m W/CONC. FOOTING 2.616 m W/CONC. FOOTING 3.000 m W/CONC. FOOTING 762 mm IN CONC. FOOTING 838 mm IN CONC. FOOTING 914 mm IN CONC. FOOTING 2.390 m 2.770 m 3.150 m 10.83 16.39 17.37 3.20 41mm x 32mm 88mm 406mmDIA. 457mmDIA. 406mmDIA. 304mmDIA. 406mmDIA. 609mmDIA. MAXIMUM WIDTH OF SINGLE SWING GATE TO BE 6 m MAXIMUM OPENING MAY BE UP TO 12 m WIDE. DIAMETERS AS SHOWN ARE MINIMUM VALUES. DEPTHS FOR ROCK ARE MINIMUMS. DEPTHS SHOWN FOR CONCRETE FOOTINGS IN EARTH ARE MINIMUM FOR 2 m HIGH FENCE AND MAY BE REDUCED 225 mm FOR SUBSTITUTION FORMULA ON CLASS 2 COLD FORMED STEEL PIPE. FOR SUBSTITUTION FORMULA ON CLASS 2 COLD FORMED STEEL PIPE. SECTION MODULUS AS SHOWN IS BASED UPON ASTM A53 AND AASHTO M 181M. SEE SPECIFICATIONS SECTION MODULUS AS SHOWN IS BASED UPON ASTM A 501 AND AASHTO M 181M. SEE SPECIFICATIONS BRACE BAND W/ 10 mm BOLT ( REQUIRES CONCRETE FOOTING ) ( ) W TOP RAIL OF ROADWAY. TOWARD OUTSIDE METER METER ALTERNATE DETAIL POST CAP ( W/TOP RAIL ) @ BOTTOM OF ARM AT TOP & 50 mm 350 ( MIN. ) 50 mm NOM 80 80 900 mm DEEP CROSS FENCE CONNECTOR WHEN APPROVED BY THE ENGINEER, THE PROPERTY OWNER SHALL CONSTRUCT AND MAINTAIN, AT GATE BETWEEN CORNER POSTS. THE FLOW CAN NOT BE RESTRICTED. HIS OWN EXPENSE, FENCING AND OR WATER DATE APPROVED BY ROADWAY ENGINEER DIA. DIA. 3.9mm THK. 53mm I.D. THK. THK. 3.2mm 2.7mm THK. 3.1mm THK. 40mm I.D. 3.7mm THK. THK. 3.2mm 5.2mm 5.7mm THK. 6.7mmTHK. 2.8mmTHK. 4.6mmTHK. 2.9mmTHK. 3.7mmTHK. 300 C/C mm / WIDE 2.0m 4.0m 6.0m WIDE WIDE - ( mm HIGH CLASS ) - ( mm HIGH CLASS ) HEIGHT OF FENCE OR GATE SHALL BE SPECIFIED. CLASS A DESIGNATES FENCE OR GATE WITHOUT CLIMB BARRIER CLASS B DESIGNATES FENCE OR GATE WITH CLIMB BARRIER ITEM ONLY WHEN TOP RAIL ( ) IS ADDED AS A RETROFIT ITEM, THE COST ALTERNATE CONCRETE FOOTING TO BE USED IF AND WHERE DIRECTED BY THE ENGINEER EQUALS FENCE HEIGHT ATTACHMENT OPTION WHEN WING OR WALL HEIGHT FULL HEIGHT WING/WALL 200 RE-ISSUE W/METRIC1999 SPECS. WITH THE 1999 METRIC STANDARD SPECIFICATIONS. 00M EARTH EMBEDDED - SEE SPECIFICATIONS NOTE: LINE POSTS MAY BE DRIVEN OR ( ) . ALUMINUM ALLOY. 3. THE BOTTOM BARBED WIRE MAY BE OMITTED AND FABRIC INSTALLED 25 mm BARBED WIRE 2. COST OF BARBED WIRE AND EXTRA LENGTH POSTS FOR FAN TO BE INCLUDED BARBED WIRE BARBED WIRE BARBED WIRE BARBED WIRE BARBED WIRE BARBED WIRE BARBED WIRE BARBED WIRE IN PLACE AS BARBED WIRE

m112f - okladot.state.ok.us · 5.39 cm 5.02 cm 6.03 cm cm 9.18 cm cm cm 39.17cm 89.33 cm 3.20 cm 2.70 cm3 cm 4.43 5.34cm3 ... SECTION MODULUS AS SHOWN IS BASED UPON ASTM A 501 AND

Embed Size (px)

Citation preview

Page 1: m112f - okladot.state.ok.us · 5.39 cm 5.02 cm 6.03 cm cm 9.18 cm cm cm 39.17cm 89.33 cm 3.20 cm 2.70 cm3 cm 4.43 5.34cm3 ... SECTION MODULUS AS SHOWN IS BASED UPON ASTM A 501 AND

1999 SPECIFICATIONS

ALL DIMENSIONS ON THIS SHEET IN MILLIMETERS UNLESS OTHERWISE NOTED. R-112M

ROADWAY STANDARD ( METRIC )OKLAHOMA DEPT. OF TRANSPORTATION

DESCRIPTION DATEREVISIONS

7/99

ITEM NO.

BASIS OF PAYMENT

UNIT

CLEAR FROM GROUND LINE IN LOCATIONS APPROVED BY THE ENGINEER.

ALTERNATE CLIMB BARRIERS APPROVED BY THE ENGINEER PRIOR TO

INSTALLATION MAY BE USED. FENCE POST EXTENSION ARM SHALL BE MADE OF PRESSED STEEL OR MALLEABLE IRON AND SHALL BE GALVANIZED

AFTER FABRICATION.

WIDTHS. NO FABRIC WITH TWISTS AND BARBS ON BOTH SELVAGES WILL

BE ACCEPTED.

CONNECTION STRETCHER POSTS SHALL BE EMBEDDED IN CONCRETE WHEN FENCE

IS BEING ERECTED ON EARTHEN FOUNDATIONS. OTHER POSTS MAY BE EMBEDDED

IN CONCRETE IF AND AS DIRECTED BY THE ENGINEER TO SATISFY SPECIFIC

624.06( D

624.06( E

FENCE - STYLE CLF

GATES - STYLE CLF EACH

MAXIMUM

LINE POST TENSION WIRE

LINE POST

SEE GENERAL NOTES

TIE WIRES

SEE DETAIL

ALTERNATE CONC. FOOTING

TO BE USED IF AND WHERE

DIRECTED BY THE ENGINEER

POST BRACE

RAIL

TYPICAL LINE POST DETAIL

TOP RAIL

TOP RAIL

POST BRACE

RAIL

TIE WIRES AT

STRETCHERSTRETCHER POST

BANDS

END,

CORNER, OR

SEE POST & FRAMEWORK

SCHEDULE FOR FOOTING

DIMENSIONS. CONCRETE FOOTING

CAP

END, CORNER, & STRETCHER DETAILS

USE STRETCHER DETAILS AT ALL CORNERS, BENDS IN R/W, ON HILLTOPS,

VARIABLE VARIABLE

TOP RAIL

GATE

POST

STRETCHER

BANDS

SEE GENERAL NOTES

SEE POST & FRAMEWORK

SCHEDULE FOR FOOTING

DIMENSIONS.

VARIABLE

CAP

6.0 m MAXIMUM

( SINGLE GATE) CAP

END

POST

TURNBUCKLES

TOP & BOTTOM RAIL.

TIE WIRES AT

STRETCHER BARS

SEE PLANS FOR SIZE AND LOCATION OF GATES. WHERE

GATE DETAIL

LINE POST

TIE WIRES

SEE DETAIL

SEE GENERAL NOTES

END POST

CORNER POST

GATE

STRETCHER POST

FAN

RIGHT-OF -WAY FENCE

CONCRETE FOOTING FOR POSTS

SEE PLAN AND PROFILE SHEETS FOR LOCATION.

FENCING SYMBOLS ON PLANS

FENCING SYMBOL THIS SHEET

VARIABLE VARIABLE

LINE POST FAN POST FAN POST

TIE WIRES

SEE DETAIL

VA

RIA

BL

E

LINE POST LINE POST

TENSION WIRE

TENSION WIRE

TOP & BOTTOM

TOP & BOTTOM

SEE PLANS FOR APPROX. LOCATION OF FANS.

ANGLE TO BE PLACED

FAN DETAILS

FAN POST LINE POST

TIE WIRES

SEE DETAIL

VA

RIA

BL

E SEE END

DETAIL

45 SUGGESTED

ANGLE. ACTUAL ANGLE

AS SHOWN ON PLANS

OR AS DIRECTED BY

THE ENGINEER.

SEE CORNER

DETAIL

SEE END DETAIL BRACE BAND

GENERAL NOTES

ELEVATION

CULVERT CONNECTION

PLAN

FASTNER

( NOM. )

SECTION A-A

VA

RIA

BL

E

AP

PR

OX

.

MA

X.

MA

X.

A

A

45

EXTENSION ARM DETAIL

EXTENSION ARM

SEE DETAIL

INSIDE OR OUTSIDE

CONNECTION MAY

BE USED.

EXTENSION ARMS SHALL BE

FITTED WITH WIRE CLIPS OR

HOOKED NOTCHES TO HOLD

APPROVED BY THE ENGINEER.

ANGULAR CLIMB BARRIER

FOR LINE POSTS

VERTICAL CLIMB BARRIER

FOR END & GATE POSTS

DOUBLE GATE LATCH

MA

X.

MA

X.

MA

X.

C

E

B

A

D

F

A

B

C

D

LOCK KEEPER

LOCK KEEPER GUIDE

LOWER FORKS

UPPER FORKS

E

F

LOWER GUIDE

UPPER GUIDE

A

B

ALTERNATE TYPE LATCH MAY BE USED IF APPROVED BY THE ENGINEER.

TYPICAL GATE LATCH DETAIL

SINGLE GATE LATCH

LINE POST

TIE W

IRE W

RA

PPED 2

TUR

NS M

IN. E

AC

H

SIDE O

F PO

ST

TIE WIRE DETAIL

WIRE FABRIC TO BE WOVEN INTO LOCK LOOPS FOR THE ENTIRE WIDTH OF THE FABRIC.

AS

SH

OW

N

ON

PL

AN

S

AS

SH

OW

N

ON

PL

AN

S

FOOTING REQUIREMENTS.

IN PRICE BID FOR CHAIN LINK FENCE.

2 VERTICAL BRACES AT 1/3 POINTS.

ON

PL

AN

S

AS

SH

OW

N

BRACE BAND

LATCH

GATE

BRACE RAIL

POST GATE

HINGES

TE

NS

ION

WIR

ES

A

A

45

ALTERNATE

DETAIL

EXTEN. ARMWRAPPED

2 WRAPS

( MIN. )

TOP RAIL MAY BE USED IN LIEU LINE

POST

CL

IPP

ED

AT

APPROVED BY THE ENGINEER.

OF BARBED TOP WIRE, IF

WHEN TOP RAIL IS USED IN LIEU OF BARBED TOP WIRE THE COST

OF TOP RAIL SHALL BE INCLUDED IN THE PRICE BID FOR FENCE.

IN VALLEYS OR DEEP DEPRESSIONS AND AT 150 METERS MAXIMUM SPACING.

600 mm C/C 600 mm C/C

VALLEYS AND AT A MAXIMUM OF 150 m APART.

A, B

OR

C

A, B

or

C

A,

B o

r C

AS

SH

OW

N

ON

PL

AN

S

A, B

OR

C

80 80

150

150

80

140

140

50

80

350 ( M

IN. )

140

140

50

)

)

965

100

80

80

150

80

80

80

10

0

100

50

150

80

80

80

80

1. ALL CONSTRUCTION AND MATERIAL REQUIREMENTS SHALL BE IN ACCORDANCE

4. ALL MISCELLANEOUS HARDWARE SHALL BE FURNISHED GALVANIZED OR

5. CLIMB BARRIER SHOWN INTENDED ONLY TO SHOW AN ACCEPTABLE TYPE.

6. CHAIN LINK FABRIC MAY BE ACCEPTED KNUCKLED BOTH SELVAGES IN ALL

7. STRETCHER POSTS TO BE USED IN GENERAL AT HILL TOPS AND AT BOTTOM OF

8. ALL POSTS WITH THE EXCEPTION OF LINE POSTS, FAN POSTS AND HEADWALL

150

CLIPPED AT 300 mm C/C

STRETCHER BARSTRUSS RODS

10 mm

TIE WIRES AT 600 mm C/C

TRUSS ROD

10 mm

5 mm x 19 mm

BRACE BAND w/10 mm BOLT

TOP & BOTTOM TENSION

WIRES CLIPPED AT

AT 600 mm C/C

NOTE: GATES WIDER THAN 3.6 m REQUIRE

DOUBLE SWING GATES WITH MIDDLE LATCH.

WIDTH GREATER THAN 6.0 m IS REQUIRED, USE

3.6 m ( MAX.)3.6 m ( MAX.)3.6 m ( MAX.)3.6 m ( MAX.)3.6 m ( MAX.)

( MA

X.)

( MA

X.)

50 mm

CLIPPED AT 300 mm c/c

CLIPPED AT 300 mm c/c

AP

RX

. 2

5 m

m

10 mm TRUSS ROD5 mm x 19 mm

TRUSS ROD

10 mm

LINE

POST

TOP RAIL932.16

OF TOP RAIL, INCLUDING ALL HARDWARE FOR INSTALLATION, SHALL

BRACE BAND W/10 mm BOLTBRACE BAND W/10 mm BOLT

W/10 mm BOLT

W/10 mm BOLT

BE PAID FOR AS TOP RAIL, BY THE LINEAR METER, AS INSTALLED.

3.6 m 2.4 m 2.4 m 2.4 m 2.4 m

20

0

22

FOR EACH METER OF FENCE HEIGHT LESS THAN 2 METERS HIGH.

"X"

"X"

STRETCHER SECTION AS SHOWN

SEE TABLE FOR

CHORD LENGTH þÿ���C�LENGTH

STRETCHER SECTION AS SHOWN

R/W

SEE TABLE FORCHORD LENGTH

þÿ���C�LENGTH

RADIUSSPACING FOR STRETCHER SECTION

TYPICAL PLACEMENT FOR CURVES

300

300

SPACING FROM

R/W TO FENCE

"X" mm

1600

1400

1200

1000

800

600

590

500

450

400

350

300

290

250

200

370

380

395

410

440

485

375

390

400

415

430

450

360

370

385

CURVE RADIUS

OVER 1600 m

CHORD LENGTH

600 m TO 1600 m 29.8 m

19.0 m

11.8 mLESS THAN 300 m

STD. FENCE

590 m300 m TO

RIGHT - OF - WAY FENCE

STYLE - CLF

( CHAIN LINK FENCE )

RWF3-1

SHAPE

DIMENSIONS

CRITICAL AXIS

SEC. MODULUS

NOMENCLATURE

WEIGHT

LENGTH

FOR GIVEN

FENCE FAB. HT

EMBEDMENT

FOR GIVEN

FENCE FAB. HT

A

B

C

FOOTING DIM.

IN EARTH

FOOTING DIM.

IN ROCK

LINE POST

PIPE

ROLL ROLL

FORMED FORMED "H"

RAIL

4.05

43mm 43mm

3.93 2.75 4.85

STAND.

"C"

HEAVY

"C"

POST & FRAMEWORK SCHEDULE

PIPE

88mm x

ROLL

FORMED PIPE PIPE PIPE

102mmO.D.

END, CORNER, OR

STRETCHER POSTS& LESS

GATE POSTSTOP RAIL OR

GATE FRAMES

POST BRACE RAIL2.0mWIDE

GATES UP TO GATES 2.1m GATES 4.1m

PIPE PIPE PIPE PIPE

ROLL

FORMED

1.91mmTHK.

13.55 7.22 5.43

48mmO.D. 57mm x 48mm x

42mm

57mm x 60mmO.D. 73mmO.D. 141mmO.D. 42mmO.D.

2.1m TO 4.1m TO

TO 4.0m TO 6.0m

42mmO.D. 48mmO.D. 48mmO.D.

3.21 2.69 2.00 2.69 21.75 8.62

225mmDIA.

100mmDIA.

225mmDIA.

150mmDIA. 125mmDIA. 150mmDIA. 200mmDIA.

355mmDIA. 304mmDIA.

2.083m W/CONC. FOOTING; 2.235m IF DRIVEN.

2.464m W/CONC. FOOTING; 2.616m IF DRIVEN.

2.845m W/CONC. FOOTING; 3.000m IF DRIVEN.

600mm IN CONC. FOOTING; 500mm IF DRIVEN.

675mm IN CONC. FOOTING; 500mm IF DRIVEN.

750mm IN CONC. FOOTING; 900mm IF DRIVEN.

A

B

C

5.39 5.02 6.03 9.18 39.17 89.33 3.20 2.70 4.43 5.34 cm 3cm 3cm 3cm 3cm 3cm 3cm 3cm 3cm 3cm 3cm 3cm 3cm 3cm 3

( kg/m ) 4.02

41mm I. D.42mm I. D.37mm37mm I. D. I. D.128mm14mm63mm I. D.I. D.I. D.

900 mm

990 mm

1050 mm

38 mm127 mm 38 mm88 mm 32 mm 32 mm63 mm 50 mm38 mm

225 mm DIA.

100 mm DIA.

225 mm DEEP

2.235 m W/CONC. FOOTING

2.616 m W/CONC. FOOTING

3.000 m W/CONC. FOOTING

762 mm IN CONC. FOOTING

838 mm IN CONC. FOOTING

914 mm IN CONC. FOOTING

2.390 m

2.770 m

3.150 m

10.83 16.39 17.37 3.20

41mm x

32mm88mm

406mmDIA. 457mmDIA.

406mmDIA. 304mmDIA. 406mmDIA. 609mmDIA.

MAXIMUM WIDTH OF SINGLE SWING GATE TO BE 6 m MAXIMUM OPENING MAY BE UP TO 12 m WIDE.

DIAMETERS AS SHOWN ARE MINIMUM VALUES. DEPTHS FOR ROCK ARE MINIMUMS. DEPTHS SHOWN FOR

CONCRETE FOOTINGS IN EARTH ARE MINIMUM FOR 2 m HIGH FENCE AND MAY BE REDUCED 225 mm

FOR SUBSTITUTION FORMULA ON CLASS 2 COLD FORMED STEEL PIPE.

FOR SUBSTITUTION FORMULA ON CLASS 2 COLD FORMED STEEL PIPE.

SECTION MODULUS AS SHOWN IS BASED UPON ASTM A53 AND AASHTO M 181M. SEE SPECIFICATIONS

SECTION MODULUS AS SHOWN IS BASED UPON ASTM A 501 AND AASHTO M 181M. SEE SPECIFICATIONS

BRACE BAND W/ 10 mm BOLT

( REQUIRES CONCRETE FOOTING )

( )W TOP RAIL

OF ROADWAY.

TOWARD OUTSIDE

METER

METER

ALTERNATE

DETAIL

POST CAP

( W/TOP RAIL )

@ B

OT

TO

M O

F A

RM

AT

TO

P &

50 m

m

350 ( M

IN. )

50 mm

NOM

80

80

900 mm DEEP

CROSS FENCE CONNECTOR

WHEN APPROVED BY THE ENGINEER, THE PROPERTY

OWNER SHALL CONSTRUCT AND MAINTAIN, AT

GATE BETWEEN CORNER POSTS. THE FLOW

CAN NOT BE RESTRICTED.

HIS OWN EXPENSE, FENCING AND OR WATER

DATEAPPROVED BY ROADWAY ENGINEER

DIA.

DIA.

3.9mm THK.

53mm I.D.

THK.THK. 3.2mm2.7mmTHK.3.1mmTHK.

40mm I.D.

3.7mm THK.THK.3.2mm 5.2mm 5.7mm THK. 6.7mmTHK. 2.8mmTHK. 4.6mmTHK. 2.9mmTHK. 3.7mmTHK.

30

0

C

/C

mm

/

WIDE2.0m

4.0m 6.0mWIDE WIDE -( mm HIGH CLASS )

-( mm HIGH CLASS )

HEIGHT OF FENCE OR GATE SHALL BE SPECIFIED.

CLASS A DESIGNATES FENCE OR GATE WITHOUT CLIMB BARRIER

CLASS B DESIGNATES FENCE OR GATE WITH CLIMB BARRIER

ITEM

ONLYWHEN TOP RAIL ( ) IS ADDED AS A RETROFIT ITEM, THE COST

ALTERNATE CONCRETE FOOTING TO BE USED IF AND WHERE DIRECTED

BY THE ENGINEER

EQUALS FENCE HEIGHT

ATTACHMENT OPTION

WHEN WING OR WALL HEIGHT

FULL HEIGHT WING/WALL

200

RE-ISSUE W/METRIC1999 SPECS.

WITH THE 1999 METRIC STANDARD SPECIFICATIONS.

00M

EARTH EMBEDDED - SEE SPECIFICATIONS

NOTE: LINE POSTS MAY BE DRIVEN OR

( ).

ALUMINUM ALLOY.

3. THE BOTTOM BARBED WIRE MAY BE OMITTED AND FABRIC INSTALLED 25 mm

BARBED WIRE

2. COST OF BARBED WIRE AND EXTRA LENGTH POSTS FOR FAN TO BE INCLUDED

BARBED WIRE BARBED WIRE

BARBED WIRE

BARBED WIRE

BARBED WIREBARBED WIRE

BARBED WIRE

BARBED WIRE IN PLACE AS

BARBED WIRE