85
1 © Copyright 2014 EMC Corporation. All rights reserved. © Copyright 2014 EMC Corporation. All rights reserved. © Copyright 2014 EMC Corporation. All rights reserved. Partners enablement session EMC Storage & Backup Solutions KSA – December 2014 Mohamed Raafat Presales Consultant – EMC Redington Value Division Saudi Arabia

M. Rafaat_EMC_Presentation

Embed Size (px)

Citation preview

Page 1: M. Rafaat_EMC_Presentation

1© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Partners enablement session EMC Storage & Backup SolutionsKSA – December 2014

Mohamed RaafatPresales Consultant – EMCRedington Value DivisionSaudi Arabia

Page 2: M. Rafaat_EMC_Presentation

2© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

EMC VNX2 SERIES

EMC DD SERIES

Page 3: M. Rafaat_EMC_Presentation

3© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

SIMPLIFY MANAGEMENT

CONTROL COSTS

KEEP DATA SAFE

IT Departments Need HelpThey need to

Page 4: M. Rafaat_EMC_Presentation

4© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Entry-Level Storage Redefined!EMC’s newest, unified hybrid array

VNX5400 VNX5600 VNX5800 VNX7600 VNX8000VNX5200

NEW!

VNXe3200

UP TO 6 PB CAPACITY

UP TO 4X Performance, Just as Affordable

Page 5: M. Rafaat_EMC_Presentation

5© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

EMC VNXe3200 Unified Hybrid Array

Set up NAS or SAN

in under 15 minutes

VMware Ready:VAAI, VASA,

ESX Auto-discovery

Windows Ready: SMB3, ODX, SMI-S

NPIV, MMC, PowerShell

UnifiedFibre Channel (new) iSCSI,

NFS, CIFS, SMB3

Flash OptimizedFAST-VP SSD autotiering

and FAST Cache

Unified Snapshots Built-in: for file/block

Unified

SIMPLE. EFFICIENT. PROTECTED.

MOST AFFORDABLEUNIFIED HYBRID

Page 6: M. Rafaat_EMC_Presentation

6© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

SimpleEnjoy a better storage lifecycle – setup, manage, and support

VIRTUALIZATIONINTEGRATION

Deploy applications faster

VASA | VAAI | ESA

SMB3 | ODX | SMI-S | NPIV

SIMPLE,UNIFIED SYSTEM

Set up NAS/SAN in under 15 minutes

FILEBLOCK

EMC CONNECT PROACTIVE SUPPORT

Resolve problems 5x faster

Page 7: M. Rafaat_EMC_Presentation

7© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

EfficientSmall footprint, incredible value

MCx MULTICORE OPTIMIZATION

Deliver 3X more VM’s

VM’s Databases Files

FLEXIBLE EFFICIENCY FEATURES

Reduce capacity by up to 50%

FAST SUITE CACHING & AUTOTIERING

Set it and forget it

SSD

HDD

Page 8: M. Rafaat_EMC_Presentation

8© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

ProtectedPowerful built-in and add-on capabilities

NATIVE FILE/BLOCK UNIFIED SNAPSHOTS

Schedule storage pool snapshots

VSPEX DATA DOMAINBUNDLES

Separate protection domain

Page 9: M. Rafaat_EMC_Presentation

9© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Expanded Connectivity OptionsNew Fibre Channel and enhanced iSCSI connectivity

8GB/s FIBRE CHANNELOptional 4 port IO ModuleAuto-Negotiates to 4Gb/s

NATIVE ISCSIFour onboard 10 GbE ports

Auto-negotiate to 1 GbE

NEW!

Page 10: M. Rafaat_EMC_Presentation

10© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Setup NAS or SAN in Under 15 minutesUsing the new improved VNXe Configuration Wizard

TEST DRIVE

Experience the new VNXe.Get the free simulator today.

No registration required.Windows operating system.

VNXe3200DEMO SIMULATOR

FREE DOWNLOAD

Page 11: M. Rafaat_EMC_Presentation

11© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

#1

96+ integration points into both VMware® and Hyper-VRedefining Virtualization Integration

VASA | VAAI | ESA

SMB3 | ODX | ESI | NPIV

Analyst firm Wikibon named EMC VNX/VNXe the #1 storage for VMware integration in 2011, 2012, and 2013.

ESX auto-discovery Simplified provisioning Faster VM copies Deeper visibility More overall control

Deploy Applications Faster

Page 12: M. Rafaat_EMC_Presentation

12© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNXe3200 Rear View

• 2U DPE containing two SPs• Two 875W AC power supplies, one per SP• Six 56mm fan modules, three per SP• Shown in “System Health” page in Unisphere

Fan Modules Fan Modules

Power Supply

SP B SP A

Power Supply

Page 13: M. Rafaat_EMC_Presentation

13© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

• Modular system design– All major components are customer

replaceable units– Easy to identify and access

• Simple to service and upgrade– Clear visual repair instructions– Tool-less access to replaceable

components– Keyed for proper placement– “How-to” videos

• Minimal component sparing

• Efficient CRU replacement process

Modular Design

Page 14: M. Rafaat_EMC_Presentation

14© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNXe3200 SP Ports

Mgmt PortService

Port

4x 10GbE2x

SASMini-USB

For FC eSLIC

Fibre Channel eSLIC• 4x8Gb FC ports (speeds 2/4/8Gb)• symmetrical configuration - The

same type of eSLIC must be installed on both SPA and SPB

• Either 0 or 1 eSLIC per SP

eSLIC Fault

Port Link

Page 15: M. Rafaat_EMC_Presentation

15© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Fibre Channel eSLIC System-defined WWNs

– No user actions to create/modify/delete FC interfaces

All FC interfaces (WWNs) available for Host Access

Just set port speed– Symmetrical configuration

on both SPs

eSLIC Fault Port Link

Page 16: M. Rafaat_EMC_Presentation

16© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

mSATA• 32GB Flash• Replaces USB and SSD Bootflash configuration• Physically located underneath each SP• Contains logical partitions for:

– Boot, Root, Cores, Swap – PMP (SP cache content during power loss)– IR (Image repository for firmware)

• Boot and Root partitions can be automatically reimaged from backend disks

Top Bottom

Page 17: M. Rafaat_EMC_Presentation

17© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Faster problem detection and resolution Simplified Troubleshooting

Order replacement parts directly from Unisphere!

Identify failed components Receive context-sensitive alerts Get direct access to EMC support

Page 18: M. Rafaat_EMC_Presentation

18© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

GLOBAL EMC SUPPORT CENTERS

Resolve Problems 5X FasterWith the EMC Connect Proactive Support Ecosystem

SOFTWAREDOWNLOAD

HOW TO VIDEOS

SUPPORTFORUMS

LIVE CHATSECURE REMOTEDIAL-HOME (ESRS)

DRIVE ORDERING

Page 19: M. Rafaat_EMC_Presentation

19© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNXe3200 Drive Support (O.E. 3.0.1.3513260)

Drive Type(2.5” Drives)

Capacity 12 Drive DAE*

25 Drive DAE

FAST Cache Optimized SSD 100GB ✔ ✔

FAST Cache Optimized SSD 200GB ✔ ✔

FAST VP Optimized SSD 100GB ✔ ✔

FAST VP Optimized SSD 200GB ✔ ✔

15K RPM SAS 300GB ✔ ✔

10K RPM SAS 600GB ✔ ✔

10K RPM SAS 900GB ✔ ✔

Drive Type(3.5” Drives)

Capacity 12 Drive DAE

15K RPM SAS 300GB ✔

15k RPM SAS 600GB ✔

7.2K RPM NL-SAS 2TB ✔

7.2K RPM NL-SAS 4TB ✔

* 2.5” drives supported in 3.5” carriers

Additional Note:System Drives Supported: 200GB FAST VP SSD, 300GB (15K) SAS, 600GB (15k) SAS, 600GB (10K) SAS, 900GB (10K) SAS, 2TB (7.2k) NL-SAS , 4TB (7.2k) NL-SAS

Page 20: M. Rafaat_EMC_Presentation

20© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

EMC VNXe SeriesSimple. Efficient. Protected. VNXe3200

Form factor (Minimum) 2U

Storage Processors (SPs) 2

Processor Cores per SP 4

Total System memory 48 GB

Maximum drives 150*

Max FAST Cache 200GB

Drive types SAS, NL-SAS, Flash

Protocols CIFS, NFS, iSCSI & Fibre Channel

Embedded I/O ports per SP 4 x 10GBaseT Ethernet

Configurable I/O slots per SP 1

I/O slot options available 4 x 8Gb/s Fibre Channel

Backend Connectivity per SP 2 x 6 Gb/s SAS

* Initial support is for 50 drives

Page 21: M. Rafaat_EMC_Presentation

21© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

• 3rd generation VNXe Series Unified Platform

• What’s New:– Fibre Channel– Native iSCSI – Greater performance with:

• Sandy Bridge Processors & more Memory• MCx (Multicore Everything)

– Multicore Cache (DRAM)– Multicore FAST Cache– Multicore RAID

– Fully Optimized Tiering with FAST VP– Unified layered software:

• VNXe Unified Snapshots for File & Block

– Simple and Extensive Management• Enhanced Unisphere & Unisphere Central• Monitoring and Reporting

VNXe3200The Most Affordable FLASH-optimized Hybrid Array

Unified

VAAI and VASA

integration

SMB3, ESI, SMI-S, SCVMM

SIMPLE. EFFICIENT. PROTECTED.

Page 22: M. Rafaat_EMC_Presentation

22© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

• Simple, Efficient & Protected– Integrated Unified

implementation (no X-Blades, Control Stations, etc. to manage)

– Provides balanced performance, scalability and flexibility

VNXe's Purpose Designed ArchitectureIntegrated Unified Storage

Flexible Drive Options

Capacity (NL-SAS)

Performance(SAS)

Extreme Performance(FLASH)

Storage Processor “B” Storage

Processor “A”

FC iSCS

I

NFS

CIFS

Page 23: M. Rafaat_EMC_Presentation

23© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

FAST Suite Optimizes the VNXe3200Improve performance while lowering storage costs

FAST VP AUTOTIERING

Set it and forget it hot spot rebalancing

200 GB FAST CACHE

Extend cache with SSDs for a 3X boost

SSD

HDD

Page 24: M. Rafaat_EMC_Presentation

24© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Hot data is relocated to SSD slices whilecold data is relocated to low-cost HDD slices2

Customers can reduce drive count by up to 66% while increasing performance (IDC)3

FAST VP slices storage into 256 MB slices and begins measuring performance1

FAST VP saves money and time with autotieringAutomated Data Relocation and Tiering

HOW FAST VP AUTOTIERING WORKS

SSD

HDD

AUTOTIERINGIN ACTION

Page 25: M. Rafaat_EMC_Presentation

25© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

..Relocation

Flash SAS NL-SAS

Most Activity

Neutral Activity

Least Activity

Storage Pool

BeforeAfter Relocating.. .• The 256MB slices are relocated according to

both the rank order and the tiering policy

• Policy Engine triggers an automatic relocation– Moves hot data to higher tiers, cold data to

lower tiers, or follow the corresponding tiering policy

• Ensures that the higher performing drives are used first

– Keeps 10% of the space in all tiers free

• Relocation Schedule:– User defined relocation window

– Defines how long the window will be open for the array to start data relocation on the participating storage pools

– User defines relocation rate

– Controls performance impact

– Can be arranged to take place during off-hours to minimize any adverse performance impact

– Start Time (Increments of 15 minutes)

– End Time (Increments of 15 minutes)

Page 26: M. Rafaat_EMC_Presentation

26© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Enable FAST Cache for a 3X workload boost*Turbocharge Your System

3X MORE

Exchange

SQL Server

Hyper-V

VMware

Citrix

VIRTUAL MACHINES

MAILBOXES

TRANSACTIONS

VIRTUAL DESKTOPS

VMware

*Compared to performance without FAST Cache.

ENABLE FAST CACHE ENABLE FAST CACHE

Page 27: M. Rafaat_EMC_Presentation

27© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

• Large-capacity, array-wide secondary cache– Benefits the entire system– Continuously ensures that the hottest data is served

from Flash drives– Enabled at the Storage Pool level– Caches data at 64KB page granularity

• Positioned between:– Storage Processor’s DRAM-based primary cache– Hard-Disk Drives (HDD)

• Increased storage capacity compared to DRAM

• Less latency compared to HDD

• Multicore FAST Cache tasks can scale to multiple CPU cores

Multicore FAST Cache

HDD

Multicore FAST Cache

Multicore Cache (DRAM)

Processor

Configured in RAID 1 pair

Flash Drives Configuration

100 GB 2x 100GB

200 GB 2x 200GB

Page 28: M. Rafaat_EMC_Presentation

28© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Multicore FAST CacheWhere workloads will see a benefit

Multicore Cache (DRAM)

Sequential I/OHigh-frequency access patternsZero fill requestsI/O larger than 64KB

Multicore FAST Cache– Random I/O– I/O smaller than 64KB

Page 29: M. Rafaat_EMC_Presentation

29© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

• Permanent Sparing– Any unused drive is a possible spare

• No Hot Spare creation is necessary or possible

– Spares become a permanent part of the RAID Group• Equalize operations no longer occur

– Recommended Hot Sparing policy• 1 spare per 30 (enforced by system)

– Exception: A single 12 drive DPE configuration

• Portable Drives– Drives can be relocated between buses, enclosures, etc.

• Each physical drive is identified as a Physical Virtual Drive (PVD) • VNXe3200 keeps track of PVDs by their serial numbers

– 5 minute timeout before spare invoked– Used for bus balancing– Remove whole RAID groups for longer periods (as long as Drives are returned to array)

Multicore RAIDBus 0, Enclosure 1

RAID group 1

RAID 6 Performs Parallel Rebuilds• Drive Fails• Spare rebuild starts• Second drive fails• Spare is found• Rebuild starts from the same block as first• Rebuild wraps around

Page 30: M. Rafaat_EMC_Presentation

30© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

MORE EFFICIENT RAID 5

15K , 7.2K HDD or SSD

+112

More Usable Capacity — Less OverheadImproved RAID

Efficiency

MORE EFFICIENT RAID 6

7.2K HDD

+ 28 or 14

4 or 8 +1

TRADITIONAL RAID 5

15K, 7.2K HDD or SSD

TRADITIONAL RAID 6

6 or 10 + 27.2K HDD

Page 31: M. Rafaat_EMC_Presentation

31© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Reduce Capacity by up to 50%Lower capacity requirements with advanced efficiency services

File Deduplication

and Compression

Thin Provisioningwith Reclaim

Traditional storage

50%Less capacity

Page 32: M. Rafaat_EMC_Presentation

32© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Store More in Less SpaceA mixed workload powerhouse with MCx and Flash

125VIRTUAL MACHINES*

2000 EXCHANGE MAILBOXES*

20,000 SHAREPOINT USERS*

500VIRTUAL DESKTOPS*

VNXe3200 with MCx™

SandyBridge 2.2 GHzMulticore CPU Optimization

* RESULTS BASED ON VSPEX REFERENCE NUMBERS LABS

Page 33: M. Rafaat_EMC_Presentation

33© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNXe3200 Hybrid Storage BundlesMeet your needs: capacity, consolidation, performance

1ENTRY LEVEL

$11,500 LIST

3.6 TB 10K SAS

2BASE

CAPACITY36 TB NL-SAS

3ENHANCED CAPACITY

48 TB NL-SAS

4BASE

CONSOLIDATION15 TB SAS/NL-SAS

5ENHANCED

CONSOLIDATION53 TB 3 TIER FAST*

6BASE

PERFORMANCE11 TB 2 TIER FAST*

7FLASH

CONFIGURATION7 TB SAS/SSD

BUILD YOUR OWN VNXeAT THE EMC STORE TODAY

General-Purpose Storage Highest IOPSMixed, VirtualizedAll-purpose file/block consolidation VMware or Hyper-V environments VDI or demanding databases

* Includes FAST Suite

Page 34: M. Rafaat_EMC_Presentation

34© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

TEST DRIVE

Experience the new VNXe.Get the free simulator today.No registration required.Windows operating system.

VNXe3200SIMULATOR

Free Download

http://www.emc.com/collateral/demos/microsites/vnxe/vnxe-demo.exe

Page 35: M. Rafaat_EMC_Presentation

35© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Opti

ons

Bundle

s Storage Analytics*vCenter Operations Manager, EMC Adapter for VNXe

VNXe Software Choices

FAST Suite*FAST VP, FAST Cache

Base VNXe Base Software

OE, Protocols, Unisphere, Unisphere Central, M&R, Unified Snapshots, Integrated Support/Dial-Home ServicesFile Deduplication & Compression, Thin Provisioning, Event Enabler (common Anti-Virus), File Level Retention

PowerPath*Intelligent load balancing and multi-pathing

Free EMC Storage Integrator for WindowsProvision Microsoft storage three times faster

VPLEX/VE Standard Edition*Create stretched clusters and multi-site VMotion

Syncplicity*Create your own private dropbox

Data Protection Suite*Powerful EMC Backup and Archive software

* Requires separate license

Page 36: M. Rafaat_EMC_Presentation

36© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

EMC Service/Support

* Non-CRU (customer replaceable units) only ** Severity 1 issues (sev 2 = same day; sev 3/4 = NBD – next business day)

Installation of operating environment updates

Onsite response with parts installation

Replacement parts delivery

24x7 remote monitoring and repair

Global technical support***

Rights to new releases of software

24x7 access to online support tools

NBD

24x79x5 24x7

24x7x4**

Business Hours Support Essentials

24x7 Support for Production

Environments

Mission-Critical Support for Fastest

Resolution

BASIC ENHANCED PREMIUM

NBD

NBD* 24x7x4**

Standard on: VNXe3200

Page 37: M. Rafaat_EMC_Presentation

37© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Page 38: M. Rafaat_EMC_Presentation
Page 39: M. Rafaat_EMC_Presentation

39© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

EMC VNX Technical Overview

Page 40: M. Rafaat_EMC_Presentation

40© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX5400 VNX5600 VNX5800 VNX7600 VNX8000VNX5200

6 New VNX Platforms New EMC VNX Series with MCx

SIMPLE. EFFICIENT. POWERFUL. PROTECTED.

UP TO 6 PB CAPACITY

UP TO 4X Performance, Just as Affordable

Page 41: M. Rafaat_EMC_Presentation

41© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

More processing power. Self-optimizing pools. Any network. Powerful, Flexible Modular Architecture

H A R D W A R E

Multi-core and multi-node scale: MCx technology• MCx technology extends performance to unprecedented levels• Add X-blades for the right amount of file sharing power• Scales to 96 CPU cores and 4,000 drives (multiple back-ends)

Self-optimizing storage pools• Active Data is automatically moved to Flash for fastest performance• Inactive Data is automatically moved out of Flash to large disks for

lowest capacity cost• Fully Automated. Always on. No management intervention needed.

Set-it-and-forget-it.• Lowest transaction cost and lowest capacity cost—simultaneously!

Unified multi-protocol• Full support for any network• Unified block, file and object• Share volumes and files • Fully provisioned LUNs

SSD HDD

Future proof• Flexible IO options• Plug and play• Low-end DC Unified

Options available*

SAN

BLOCKiSCSI

FC

FCoE

NAS

FILECIFS

NFS

pNFS

MPFS

CLOUD

OBJECTREST

SOAP

* DC NEBS Systems planned for Q3 2014

Page 42: M. Rafaat_EMC_Presentation

42© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Dynamic Multicore Optimization

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

Core Number

Core

Uti

lizati

on

Static Core Utilization

Breakthrough Midrange Innovation!

RAID I/O DRAM Cache FAST Cache Data Services Management Available

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

Core Number

Core

Uti

lizati

on

43

Page 43: M. Rafaat_EMC_Presentation

43© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Software SuitesPackage/Suite Contents

VNX Operating Environment(REQUIRED)

VNX OE for File (base file services)VNX OE for Block (base block services)This includes protocols, thin provisioning, block deduplication, block compression,file deduplication and compression, SAN Copy, and ODX Enabler

VNX Unisphere Management Suite(REQUIRED)

Unisphere (Unisphere for Block, Unisphere for File or Unisphere for Unified)Unisphere CentralUnisphere Analyzer, Unisphere QOSVNX Monitoring and Reporting (storage-only version of Watch4Net)

EMC Storage Analytics for VNX VMware vCenter Operations Manager for VNXEMC Adapter for VNX

VNX Events and Retention Suite File Level RetentionCommon Event Enabler (CEE) –Common AV Agent and Common Event Publishing Agent

Total

Efficiency Pack

VNX FAST Suite FAST CacheFAST VP

VNX Local Protection Suite SnapSure, SnapViewRecoverPoint SE CDPVNX Snapshots

Total

Protection Pack

VNX Remote Protection Suite ReplicatorMirrorView A/SRecoverPoint SE CRR

VNX Application Protection Suite AppSyncReplication Manager

Page 44: M. Rafaat_EMC_Presentation

44© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX System Architecture

Flash drivesSAS drives

LCCLCC

SPSSPS

Power Supply

Power Supply

LAN

Near-Line SAS drives

VNX SP Failover

Clients

Database ServersExchange servers

VNX Unified Storage

Application servers

SAN

FailoverVNX Data Mover

VNX SP

VNX OE FILE

VNX OE BLOCK

VMware and Hyper-V

FC iSCSI TBD FC iSCSIFCoE FCoE

VNX Data MoverVNX Data MoverVNX Data Mover

10Gb Enet

10GbEnet

Object:Atmos VE

H A R D W A R E

TBD

VNX Data MoverVNX Data MoverVNX Data MoverVNX Data Mover

Page 45: M. Rafaat_EMC_Presentation

45© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX SeriesMODULAR UNIFIED GATEWAY

VNX5200 VNX5400 VNX5600 VNX5800 VNX7600 VNX8000 VG2 VG8

Max. Drives 125 250 500 750 1000 1500 4000 4000

Max FAST Cache (GB)

600 1000 2000 3000 4200 4200N/A N/A

Drive types 2.5” and 3.5”; Flash, SAS and NL-SAS BE dependent BE dependent

FILE

Configurable I/O Slots per DM

3 3 3 4 4 5 3 5

Data Movers (DM) 1 to 3 1 to 4 1 to 4 2 to 6 2 to 8 2 to 8 1 or 2 2 to 8

Capacity per Data Mover (in TBs)

256TB

CPU / Cores / Memory (per blade)

2.13GHz / 4 / 6 GB

2.13GHz / 4 / 6 GB

2.13GHz / 4 /

12 GB

2.4Gz / 4 / 12 GB

2.8GHz / 6 / 24 GB

2.8GHz / 6 / 24 GB

2.4GHz / 4 / 6 GB

2.8GHz / 6 / 24 GB

Protocols NFS, CIFS, pNFS

BLOCK

Configurable I/O Slots per SP

3 4 5 5 5 11N/A

Embedded I/O ports 2 Back-End SAS ports 0 N/A

CPU / Cores / Memory (per SP)

1.2GHz / 4 / 16 GB

1.8GHz / 4 / 16 GB

2.4GHz / 4 / 24 GB

2.0GHz / 6 / 32 GB

2.2GHz / 8 / 64 GB

2x 2.7GHz /8/ 128GB

N/A

Protocols FC, iSCSI, FCoE N/A

H A R D W A R E

Page 46: M. Rafaat_EMC_Presentation

46© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Broad Set of Capacity, Firepower & Connectivity Choices VNX Highlights – New Flexible Platforms

Mid-Market Platform

Front View

Rear View

Performance Platform

Front View

Rear View

Up to 6PB and 1.1M IOPS

>200,000 IOPs in 3U

Unified across the family

Up to 32 cores per system

Optimized for Applications

Up to 72 FC Ports

PCI-e Gen 3

NEW

H A R D W A R E

Page 47: M. Rafaat_EMC_Presentation

47© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Unified Storage Components

Block components: storage or data processor enclosure*

– VNX Operating Environment for Block– Dual active storage processors– Automatic failover– Flexible IO connectivity options

Standby power supplies (battery backup)

− SPE Only, DPE has SPS within the DPE

File components: Data Mover Enclosure– VNX Operating Environment for File– From 2 to 8 Data Movers (DM) supported

with configurable failover options– Flexible IO connectivity options

Control stations (1 or 2)

Disk array enclosures

* DPE contains disks (2.5” only); SPE does not contain disks

DPE (Disk Processor Enclosure)

3U

Control Station

Data Mover Enclosure (X-Blade enclosure)

25x 2.5” Disk Array Enclosure

15x 3.5” & 2.5” Disk Array Enclosure

SPS (SPE Only)

Disk Processor Enclosure/Storage Processor Enclosure

Optional Control Station

Start with FC or iSCSI or NAS

Add other protocols seamlessly, as needed

Flexible IO options:

4-port 8Gb FC

2 port optical10GbE

2 port copper 10GbE

4 port Copper 1GbE

2 Port 10Gb FCoE

4 Port 4 Lane 6Gb SAS

Ž

Œ�

H A R D W A R E

60x 3.5” & 2.5” Disk Array Enclosure

Simple Upgradeability: Block/File to Unified**

** VNX2 File/Block to Unified conversions will be in in a future release

Page 48: M. Rafaat_EMC_Presentation

48© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Form Factors

Block Only Base

DAE = drives only

DPE = storage processors + 2.5” drives

SPE = storage processors

Drives

Add DAEs up to the maximum capacity allowed

Can mix drive types in the same DAE (e.g. 7.2K rpm + SSD + 15K rpm +NL-SAS

Can mix different DAES in a system (e.g. 15 drives, 25 drives and 60 drive DAEs)

File Only or Unified Base

Need block hardware + file hardware

H A R D W A R E

CS (Control Station) 1 U

DME(Data Mover Enclosure)

2U

2xSPS (Standby PS) 2x2U

VNX8000

DAE-15x 3.5” & 2.5” drives(Disk Array Enclosure)

3U

DAE-25x 2.5” drives(Disk Array Enclosure)

2U

DAE-25x 2.5” drives(Disk Array Enclosure)

2U

VNX5400 to VNX7600

DPE (Disk Processor Enclosure

includes 25 x 2.5” drive slots) 3U

CS (Control Station) 1 U

DME(Data Mover Enclosure)

2U

DAE-25x 2.5” drives(Disk Array Enclosure)

2U

DAE-25x 2.5” drives(Disk Array Enclosure)

2U

DAE-15x 3.5” & 2.5” drives(Disk Array Enclosure)

3U

SPE(Storage Processor Enclosure)

4U

Page 49: M. Rafaat_EMC_Presentation

49© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

In-Family Data-in-Place Conversions*Extend VNX Investment Protection; Scale with Minimal Impact

Easily upgrade to higher performance VNX platform

No lengthy data migrations

Cost-effective scaling:Conversions across the VNX family reuse installed SAS DAEs, drives, and Flex IO Modules

ConsiderationsConversion of Disk Processor Enclosure (DPE) based VNX5400/5600/5800/7600 arrays will require replacement of DPEs with equivalent form factor DAEs, along with addition of VNX8000 SPEFor File or Unified platform, DM blades will be required to be swapped coincident with the back-end change-outSmall restriction on upgrade paths

Systems with NL-SAS as vault not upgradeable if not supported

Upgrade any VNX to any larger VNX with data-in-place

H A R D W A R E

VNX5400..VNX5800.. VNX8000

* Data in place conversions will be delivered in a future release.

Page 50: M. Rafaat_EMC_Presentation

50© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX8000: Scaling UP to leverage Intel Roadmap MCx: New Storage Processor Architecture

0 1 2

3 4 5

6 7 CB

0 1 2

3 4 5

6 7 CB

0 1 2

3 4 5

6 7 CB

0 1 2

3 4 5

6 7 CB

QPI QPI

SP A SP B

8xCMI

8xCMI

8xCMI

8xCMI

H A R D W A R E

Page 51: M. Rafaat_EMC_Presentation

51© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Storage Processor

• Block services– Virtual Pools with thick and thin LUNs– Flexible RAID options (1/0,5,6) provide optimal

performance AND protection

• Administration/management– Through Storage Processor Ethernet ports– Aggregated to single file/block view in Unisphere

• Single point of management/control

• High availability true Active/Active controller failover

• Connects to Hosts via FC, FCoE, iSCSI for flexibility of connection

• Connects to disk shelves via 4 lane 6Gbit SAS

• Enabled for in-place Encryption in secure environments

Trusted, mature, high performance block services

VNX Series

Storage Processors

PrivateNetwork

Administrator

FC/iSCSISAN

Unisphere

H A R D W A R E

Page 52: M. Rafaat_EMC_Presentation

52© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Data Movers• Up to eight independent file servers contained in a single

system– Scale by adding enclosures: 2 Data Movers per Data Mover

enclosure

• Managed as one, high-performance, high-availability server

• Connects data to the network

• VNX Operating Environment for File– No performance impact after failover– Concurrent Network File System (NFS), Common Internet File

System (CIFS) and File Transfer Protocol (FTP)

• Hot-pluggable

• Flexible N-to-M failover options

• Continues to operate even if control station fails

• No internal disks in the Gateway

Modular, scalable, runs the world’s most mature NAS OS

Data MoverData MoverData MoverData Mover

Control StationControl Station

Data Mover Enclosure

VNX Block Storage(or VMAX if Gateway)

Network

VNX series

H A R D W A R E

Page 53: M. Rafaat_EMC_Presentation

53© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Control Station

• Installation

• Administration/management– Through Data Mover and Storage Processor Ethernet ports

• Configuration changes

• Monitoring and diagnostics– Heartbeat pulse of Data Mover

• Monitors and manages Data Mover failover

• Enterprise Linux-based

• Initiates communications with Data Movers for greater security

• Single point of management/control

• Failover redundancy option

Secure management and control for VNX for file

Control StationControl Station

VNX series

Control Station

PrivateNetwork

Administrator

Unisphere

H A R D W A R E

Control Station

Page 54: M. Rafaat_EMC_Presentation

54© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Data Mover FailoverHigh availability architecture with no performance impact

Configurable Data Mover failover optionsN-to-M, Automatic, manual, none

Failover triggers:Software issueInternal network failurePower failureNon-responsive Data Mover

Failed Data Mover shut down to avoid “split-brain syndrome”

IP, Media Access Control (MAC), and Virtual LAN (VLAN) addresses are transferred

Automatic call-home of event

No performance impact after failover

Network

Data pathtransferred

Data Mover

Data Mover

Data remainsaccessible

No client-performanceimpact

Data Mover

Data Mover

Data Mover

VNX series

Control Station

Control Station

Data Mover

H A R D W A R E

Page 55: M. Rafaat_EMC_Presentation

55© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Flexible Storage Tiers

SAS back-end connect for performance and reliability

• Up to 24Gb (4x6 Gb) per SAS bus

• Point-to-point, robust interconnect

Flash (SSD) options

• Highest performing drives

• Fast Cache SSDs (SLC)

– 2.5” in 15 + 25 drive DAE

– 100 GB, 200 GB– ~5,000 IOs per second

• FAST VP SSDs (eMLC)

– 2.5”; 100 GB, 200 GB, 400 GB, 800 GB

– ~3,500 IOs per second

Optimize TCO with tiered service levels

AUTOMATIC DATA OPTIMIZATION

Highest capacity

Good performance

Highest performance

Near-line SAS(7.2K rpm)

SAS(10K/15K rpm)

Flash

SAS (HDD) options

• 3.5” drives (195 drives/ rack with 3U DAE, 555 drives / rack with 4U DAE)

– 600GB, 900GB, 1.2TB 10K

– 300 GB, 600 GB 15K

– ~ 140 (10K) to ~ 180 (15K) IOs per second

• 2.5” Drives (500 drives/ rack)– 600GB and 900GB 10K RPM

– 300GB 15K

– ~ 140 IO/s (10K), ~ 180 IOs per second (15K)

Near-line SAS (HDD) options

• 3.5” drives (195 drives/ rack)– 1TB, 2TB, 3TB and 4 TB 7.2K RPM

– ˜ 90 IOs per second

• 2.5” drives (500 drives/ rack)– 1TB 7.2K RPM; ˜ 90 IOs per second

H A R D W A R E

SAN LUNs

HostLUNs

NFS/CIFS NAS Volumes

New drives for next gen

Page 56: M. Rafaat_EMC_Presentation

56© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Bus 2, Enclosure 0

RAID group 1

Multi-Core RAIDPerformance Scale with Advanced Availability and Flexibility

Permanent and Pro-Active Sparing– Any unbound drive is a potential Hot Spare– Hot Spares become a permanent part of the

RAID Group– 3 Hot Sparing policies:

▪ Recommended▪ No Hot Spares▪ Custom

Bus 2, Enclosure 0

Bus 0, Enclosure 0

RAID group 1

RAID group 2VAULT

Bus 0, Enclosure 0

RAID group 2VAULT

Portable Drives– 5-Minute timeout before hot spare is invoked– Drives or data on drives can be relocated to

different busses and/or shelves

E F F I C I E N C Y

Page 57: M. Rafaat_EMC_Presentation

57© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Symmetric Active-Active

* Symmetric Active-Active for Classic LUNs with RecoverPoint and FAST Cache, but no SnapView or MirrorView

Active-Passive (ALUA) Asymmetric Active-Active

VNXCX

Cache Coherency Links

LUN LUN

LUN

Symmetric Active-Active

LUN

Page 58: M. Rafaat_EMC_Presentation

58© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

RAID Group RAID Group RAID Group

Tiered Storage Pool

Near-Line SAS15K SASFLASH

VNX Modular Architecture—Pools

Virtual Blended Storage Pool

• Block services provided by VNX Storage Processor

• Tiered storage– Choose storage tiers

• Extreme Performance (Flash), Performance (SAS), Capacity (NL-SAS)

– Choose protection per tier (RAID 1/0, 5, 6)

• Each Tier within a pool has a single RAID type

• Raid 5 – 4+1 or 8+1• Raid 6 – 6+2 or 14+2

– System builds RAID groups

• Tiers are aggregated into virtual blended storage pool

E F F I C I E N C Y

Page 59: M. Rafaat_EMC_Presentation

59© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Modular Architecture—LUNs and File Systems• LUNs are simply built from the

Virtual Pool with 256MB granularity

• LUNs can be shared to block connected Hosts (FC, iSCSI, FCoE)

• File services added

• LUNs are configured for file and consumed by Data Mover

• File systems optimally built via Automated Volume Management and shared via NFS or CIFS

SAN

E F F I C I E N C Y

Virtual Blended Storage Pool

Near-Line SAS

15K SASFLASH

Block Storage Processor

Data Mover File Storage PoolData Mover File Services

CIFS or NFS

LUN LUN LUN LUN

Page 60: M. Rafaat_EMC_Presentation

60© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Advanced pool optimization functionalityAutomatic Data Relocation Within A Tier

1. Storage Pool Rebalancing after pool expansion– Improves pool performance by balancing data across

all drives in pool▪ Re-distributes data across private RAID groups to

avoid hot spots▪ Allows users to expand pool capacity in small

increments

2. Load balancing within a tier– Relocates within tier, based on activity level– Occurs as part of FAST VP relocation

▪ During user-defined tiering relocation window

– “No Data Movement” tiering policy WILL allow load balance within a tier

Virtual Pool

Relo

cate

wit

hin

a T

ierAuto Rebalancing

After Expansion

E F F I C I E N C Y

Page 61: M. Rafaat_EMC_Presentation

61© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

FAST Cache Process Page requests satisfied from DRAM if

available

If not, FAST Cache driver checks map to determine where page is located

Page request satisfied from disk drive if not in FAST Cache

Policy Engine copies the page to FAST Cache if it is being used frequently

Subsequent requests for this page satisfied from FAST Cache

Dirty pages are copied back to disk drives as background activity

MAPPolicyEngine

Driver

DRAM

Flash Drives Disk Drives

* *

VDI

* * * *

Home Dir.

E F F I C I E N C Y

Page 62: M. Rafaat_EMC_Presentation

62© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

FAST Cache Configuration• FAST Cache supported for all VNX platforms

– Applicable to VNX for File and VNX for Block

• Highly scalable– Up to 4.2 TB FAST Cache – Supports Reads and Writes

• Applies to classic LUNs and pool LUNs– Thick and Thin pool LUNs

• A system-wide resource that benefits many workloads– Host application data: OLTP – Oracle + Microsoft SQL, VMware, etc.– Array-based data services: Snapshots, etc.

• Easy configuration in Unisphere

Model Max Capacity

VNX5200 600 GB

VNX5400 1 TB

VNX5600 2 TB

VNX5800 3 TB

VNX7600 4.2 TB

VNX8000 4.2 TB

E F F I C I E N C Y

Page 63: M. Rafaat_EMC_Presentation

63© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Improved Performance and Efficiency of FAST CacheMulti-Core FAST Cache

Performance enhancements– New Stack Order (MCC above MCF)

▪ Reduced cache hit pass-through overhead

– Increased promotion queue– Proactive clean optimization

▪ Improved responsiveness as promotions are not delayed by flush of dirty pages

Upper Redirector

Multi Core Cache

FAST Cache

Multi-Core RAID

Backend Driver

E F F I C I E N C Y

Page 64: M. Rafaat_EMC_Presentation

64© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Block Deduplication• Deduplication of data at 8KB

granularity– Deduplicated LUNs are Thin LUNs

• Settable per pool LUN– Thick, Thin and Deduplicated LUNs

supported in a single pool

• Freed up blocks/slices are available for re-use within storage pool

• Deduplication occurs out of band to minimize I/O impact

De-dupeEngine

UserChanges

IndexDatabase

LUN

Free Pool

Read

De-dupe

Storage Pool

LUN

• Improves VDI efficiency • Reduce $/VM deployment costs

Reduce CAPEX by 50% or More

E F F I C I E N C Y

Page 65: M. Rafaat_EMC_Presentation

65© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

File Deduplication and Compression

• Intelligent data selection– Typically avoids active data

Option to target active files

Compression support for VMs through the VNX Plug-in for VMware (VSI)

End-user file-level activation

– Tunable options by file system Size of files

Age of files

File extension

Directory filtering

Internal policy engine– Runs in the background

– Throttles to avoid negative impact on client services

• Leverages EMC technologies– Compression engine

– File single instancing engine

Capacity Savings

Traditional file data

1 TB

Up to 50%*savingsFile-level Deduplication-

enabled file system

~ 500 GB

Activedata

~100 GB

Up to 500 GB savingsDedupe and

compressed data

~400 GB

Activedata

~100 GB

Inactive ,aged data, orspecifically targeted data

~900 GB

* Deep compression algorithm in File OE V7.1 gives up to 65% savings

Page 66: M. Rafaat_EMC_Presentation

66© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Replication Usage is Increasing"Increasingly, organizations of all sizes use replication functionality as their first line of defense within their data protection schemes.”

Eric SheppardIDC Analyst

6AM 8AM 10AM 12PM 2PM 4PM 6PM 8PM 10PM 12PM

Snapshots enable multiple application restore points

CDP technology enables any point in time recovery8AM 10AM 12PM 2PM 4PM 6PM 8PM 10PM

Local Remote

CDP= Continuous Data Protection

Page 67: M. Rafaat_EMC_Presentation

67© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Local Protection Suite

VNX Snapshots / SnapSure• Instant copies of file and block

data for rapid access

• Wide range of uses:– Protection between backups– Rapid Database Restores– Copies of Production for

Development & Reporting– Data Validation

RecoverPoint Local Replication • Records all writes with an

embedded VNX splitter

• Saves transactions to a journal which enables DVR-like roll-back to any point-in-time, local or remote

• Enables hardware-independent replication with Virtual RecoverPoint Appliance (vRPA)

Snapshots and RecoverPoint for operational recovery

Page 68: M. Rafaat_EMC_Presentation

68© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

VNX Local Protection Suite

VNX Snapshots RecoverPoint Local Replication

Snapshots and RecoverPoint for operational recovery

Source LUN

Mon Tue Wed

SAP team 1

SAP team 2

Backup Reporting Other..Dev&Test

• Up to 90% space savings• Use up to 256 copies

• Up to 90% bandwidth savings• New Virtual appliance option

VPLEXiSCSI

VNX VNX Journal

iSCSI

VMVM

iSCSI

VNX VNX Journal

iSCSI

Virtual Appliance

vRPA

Primary Remote

New

Page 69: M. Rafaat_EMC_Presentation

69© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

EMC RECOVERPOINT FOR VNX

Affordable Tier-1 Data Protection

Page 70: M. Rafaat_EMC_Presentation

70© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Average Cost of DowntimeDowntime is Costly

• Lost revenue

• Business disruption

• Dissatisfied users

• Troubleshooting time

• Deferred IT activities

* Enterprise Management Associates - 2012

Average cost of application downtime is $45K/hour*

Page 71: M. Rafaat_EMC_Presentation

71© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

EXPONENTIAL DATA GROWTH

INCREASING CRITICALITY OF APPLICATIONS

BUDGET

What Drives Investment in Protection?

More information to protect, harder to restore

quickly

Protection is not a revenue-generating

investment

More of the organization is reliant

on IT

SITE OPTIONS

Leverage secondary site infrastructure

Page 72: M. Rafaat_EMC_Presentation

72© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

What if You Could…

• Have a simple approach for both local and remote replication

• Minimize data loss when a corruption occurs

• Install an affordable protection solution with Tier-1 capabilities

Page 73: M. Rafaat_EMC_Presentation

73© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

You Can with EMC RecoverPoint• Single solution for local and remote

protection

• Delivers a selectable RPO

• Reduces costs through:• Bandwidth reduction• Synchronous links over IP• Customer installable

OVER 100M RUN HOURS

OVER 10,000 DEPLOYED

800 PB+ PROTECTED

Page 74: M. Rafaat_EMC_Presentation

74© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

RecoverPoint Use Cases for VNX

• Protect against physical failures− Equipment or site loss

• Protect against data corruption− Viruses, human error

• One solution protects all applications− Eliminates need for multiple tools

Single solution for local and remote protection

VNX Local Protection

Suite

VNX Remote Protection

Suite

Local Copy

Production Site

Rep

licatio

n

Production RemoteCopy

Production Site

Replication

Production

Remote Site

Page 75: M. Rafaat_EMC_Presentation

75© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Protect Against Physical FailureReplicate one or more copies – to anywhere

• Go any distance – with FC or IP networks

• Get your data offsite efficiently – reduces bandwidth required

• Restore quickly to a known state

Page 76: M. Rafaat_EMC_Presentation

76© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Multi-Site ReplicationRemote Office

Data Protection

Disaster Recovery Redundancy

Centralize remote office replication

Reduced risk – no longer reliant on branch office staff

Faster recoveries

Multi-site redundancyProvides a higher level of protection

Protection against regional disasters

Page 77: M. Rafaat_EMC_Presentation

77© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Telco Offerings

Compression + deduplication gives a 90% reduction

using only 3.6 Mb/s

Replicated data36 Mb/s writes

0

15

1

22

3

13

9

24

0

15

1

22

3

13

9

247.3 Mb/s

Fractional T3

WAN Bandwidth ReductionReducing the WAN Payload

40 Mb/s

T3Traditional copyuses 36 Mb/s(no reduction)

0

15

1

22

3

13

9

24

RequiredBandwidth

Save over $7,000/ month

3.7 Mb/s of extra

bandwidth for other uses

$10,000 /month

$3,000 /month

Lease Payments

Page 78: M. Rafaat_EMC_Presentation

78© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Protect Against Data CorruptionFlexible recovery of your applications

• Recover to ANY point-in-time

• Locally or remotely

• Granular RPO− Ability to recover on a per-transaction

basis

− Retrieve your data to the moment before the virus attacked

− Recover to the most optimal restart point

Page 79: M. Rafaat_EMC_Presentation

79© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

CONTINUOUS

8AM 10AM 12PM 2PM 4PM 6PM 8PM 10PM 12AM

Minimize RPO with RecoverPoint

Provides DVR-like, ANY Point-In-Time access to data

12AM 12AM

BACKUP

Recovery Point Objective (RPO)

SNAPSHOTS

8AM 11PM1PM 6PM

3:27PM

DATA CORRUPTION OCCURS AT 3:28pm

12+ Hrs

3+ Hrs

Page 80: M. Rafaat_EMC_Presentation

80© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Server

How RecoverPoint Works1. Production data

written to storage

3. Writes are acknowledged back to the application from RecoverPoint, which are responsible for:

• De-duplication and compression• Monitoring and management

4. Data is sequenced, check-summed, de-duplicated, compressed, and replicated to the remote RecoverPoint over IP or Fibre Channel

5. Data is received, uncompressed, inflated, sequenced, and check-summed

r A r Cr B

6. Data written to the journal volume

Journal volume

2. VNX splitter intercepts write IO and sends a copy to LUN and to RecoverPoint

WAN

/ A / C/ B

Local site Remote site

RECOVERY!9. RecoverPoint turns

remote site into the active production site and notifies application

RecoverPoint RecoverPoint

Server

SANSAN

8. Local production site fails, RecoverPoint recovers

7. Consistent data is distributed to the remote volumes

iSC

SI

iSC

SI

vRPA vRPA

FC/iS

CSI

PRODUCTION SITE FAILURE!

vRPA vRPA

Page 81: M. Rafaat_EMC_Presentation

81© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

One Solution Protects AllSimplify your operations

• Eliminate multiple replication tools− One solution to manage all replication

• Maintains consistency across applications

− Guarantee consistent recoveries

• Offload protection processing from servers

Page 82: M. Rafaat_EMC_Presentation

82© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Simple to Install and OperatePeace of mind without complexity

• User-installable – no need for expensive services engagements

• Integrated management with Unisphere

Page 83: M. Rafaat_EMC_Presentation

83© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

RecoverPoint to Protect VNXAffordable Tier-1 capabilities for mid-range market

• Protect against both physical and operational failures

• Minimize data loss by recovering to ANY point-in-time

• Speed recovery times

• Eliminate multiple replication tools

• Reduce operational costs

Page 84: M. Rafaat_EMC_Presentation

84© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

Virtual RecoverPoint Appliance for VNX

VPLEXFC

VNX VNX Journal

FC

iSCSI

VNX VNX Journal

iSCSI

VMVM

Physical Appliance

iSCSI

VNX VNX Journal

iSCSI

Virtual Appliance

vRPARPA

Primary Remote Primary Remote

New

Virtual appliance (vRPA) reduces initial investment by up to 60%

Flexibility in resource allocation

Simplicity and lower TCO for VNX

Page 85: M. Rafaat_EMC_Presentation

85© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.

[email protected]

+966 500 67 9992