    LabVIEW Intermediate II for 8.0 Manual Course Errata

    Lesson 1: Calling Shared Libraries in LabVIEW

    None

    Lesson 2: VI Server

    Exercise 2-2, page 2-19 :

    Figure 2-5 is incorrect. The error clusters between the two Close Reference VIs should be disconnected to build the rest ofthe application. The correct block diagram for Figure 2-5 is as follows:

    Exercise 2-2, page 2-23 :

    In the Testing section, step 2, the file path for the solution should be C:\Solutions\LabVIEW Intermediate I\CourseProject\TLC Main.vi.

    Exercise 2-3, page 2-28 :

    In the Optional section, step 1, all references to VI Server: TCP/IP Access should be replaced with VI Server: Machine

    Access .

  • 7/25/2019 LV Intermediate II Errata Version 8.0_323458B-01

    2/3

    LabVIEW Intermediate II for 8.0 Manual Course Errata

    Lesson 3: Calling Objects in LabVIEW

    Exercise 3-1, page 3-11 :

    In the T esting section, step 1, if your browser does not allow redirects, enter the following path c:\Program Files\NationalInstruments\LabVIEW 8.0\readme\readme.html.

    Exercise 3-2, page 3-12 :

    The Generate VI Statistics HTML.VI in VI Statistics Report.vi has a bad linkage to the subVIs. To resolve the issue, open theBlock Diagram for non-functioning Generate VI Statistics HTML.vi and right-click on each of the grayed-out subVIs (NewReport.vi, Append Text.vi, and Dispose Report.vi) and select Relink subVI . The top level VI will now be operational.

    Exercise 3-5, page 3-43 :

    Figure 3-20 is incorrect. The Compound Arithmetic function should be set to AND, as described on page 3-44. The correctfigure is as follows:

    Lesson 4: Broadcasting Data

    None

  • 7/25/2019 LV Intermediate II Errata Version 8.0_323458B-01

    3/3

    LabVIEW Intermediate II for 8.0 Manual Course Errata

    Lesson 5: Serving Data to a Client Using TCP/IP

    Exercise 5-2, page 5-22 :

    Figure 5-17 is incorrect. The correct figure for the TCP File Receiver block diagram is as follows:

    Lesson 6: Publishing Data to a Subscr iberExercise 6-1, pages 6-20 to 6-21 :

    In the Test section, the path in steps 5 and 9 should be \\\Shared Data.lvlib\Stop.