18
136 design: Luca Trazzi Lux 350/400 - Twin programme Outdoor spotlights for the illumination of buildings, car parks, streets and public spaces. It is available in two sizes: Ø 350 mm and Ø 400 mm with five different beams, so as to satisfy the most varied technical lighting requirements. Lux 400 page 146 Lux 350 page 142 for a wider range, see catalogue

LUX 350_400_TWIN_ENG

Embed Size (px)

DESCRIPTION

Outdoor spotlights for the illumination of buildings, car parks, streets and public spaces. It is available in two sizes: Ø 350 mm and Ø 400 mm with five different beams, so as to satisfy the most varied technical lighting requirements. 136 design: Luca Trazzi for a wider range, see catalogue

Citation preview

136

design: Luca Trazzi

Lux 350/400 - Twin programme

Outdoor spotlights for the illumination of buildings, car parks, streets and public spaces.It is available in two sizes: Ø 350 mm and Ø 400 mm with five different beams, so as to satisfy the most varied technical lighting requirements.

Lux 400 page 146Lux 350 page 142

for a wider range, see catalogue

137

Lux 350/400 - Twin

Twin support system for Lux 350 and Lux 400 installation, consisting of cast aluminium fixing brackets, steel arm and tie rod; it is set up for use with the most common pole diameter sizes.

arm Twin 1 page 148 arm Twin 2 page 150 arm Twin 3 page 152

138

Lux 350 - Twin programme

Types of optic for Lux 350

Street optic

The street optic has been designed so as to concentrate most of the light it produces onto the road surface below, meaning that fewer installations are required and thus limiting maintenance and electricity costs.The optic system can be used to achieve high and uniform luminance on the road while limiting glare.Illumination class: ME3c

MH 150 W G12

L Ø Emed

3.00 0.36 33659

MH 150 W G12

L Ø Emed

3.00 0.94 4550

MH 150 W G12

L Ø Emed

3.00 2.24 911

MH 150 W RX7s-24

H B I Lm Uo UL TI

7.50 6.00 24.00 1.3 0.4 0.5 3

Super spot optic

Suitable for the illumination of architectural details from a distance: spires, statues and capitals.

Spot optic

Suitable for the illumination of large architectural details: monuments, fountains and gardens.

Flood optic

Suitable for the uniform illumination of large surfaces: facades, large green spaces and large architectural constructions.

139

programme Lux 400 - Twin

Types of optic for Lux 400

Combined pole installation

Lux 350 and 400 spotlights can be pole-mounted, and may be applied in various size, wattage and optic combinations.

MH-T 250 W E40

L Ø Emed

3.00 1.05 5068

MH-T 250 W E40

L Ø Emed

3.00 1.95 1314

L = distance of the spotlight from the wall [m]Ø = diameter of the illuminated surface [m]Emed = average illuminance [lux]

Road surface C2, q0=0.070H= fixture height [m]B = road width [m]I= distance between poles [m]Lm= average maintained luminance [cd/m2]Uo= general uniformity of luminance UL= longitudinal uniformity of luminance TI= physiological glare index [%]Em= average illuminance [lx] Emin= minimum illuminance [lx]

Spot optic

Suitable for the illumination of large architectural details: monuments, fountains and gardens.

Flood optic

Suitable for the uniform illumination of large surfaces: facades, large green spaces and large architectural constructions.

140

360°

360°

360°

360°

4,000

6,000

8,000

10,000

140

Lux 350/400 - Twin programme

Twin 1 spotlight rotation

Twin 2 spotlight rotation

Twin 3 spotlight rotation

141

design: Luca Trazzi

spotlight Lux 350/400

BodyDie-cast aluminium body and closure glass support ring. The tempered safety glass is fixed to the ring, and the steel spotlight fixing bracket is bolted to the body using two stainless steel screws.

Light sourcesDouble-cap and single-cap metal halide lamps. Single-cap tubular high-pressure sodium lamps.

EmissionsLux 350: super spot optic, spot optic, flood optic, street optic and asymmetrical optic.Lux 400: spot optic and flood optic.

Power supplyPhased electromagnetic ballasts with thermal cutout. Timed ignitors with digital deactivation prolong the life of the components by avoiding unnecessary discharge lamp ignition attempts when they have been exhausted.

AccessoriesWall/floor-mounting bracket, stake, ring for elliptical projection glass, coloured filters, protective grille, ring-shaped baffle and visor.

Colours Embossed-effect grey, anthracite grey or corten finishing.

easy access to the lamp compart-ment

water drainage system

vertical aim positioning (240°) heat dissipator

Lux 350

Lux 400

142

70W

MH-TE27

70W

MH-TE27

150W

MHG12

250W

MHG12

150W

MHG12

70W

SHP-TE27

70W

MH-TE27

150W

MHG12

70W

SHP-TE27

Ø 3

50

56

357

Ø 1

66

215

86 7932

Lux 350 spotlight

Light source Wattage Socket W [kg] Code

MH-T 70 W E27 10.5 75445.__MH 150 W G12 11.0 75430.__MH 250 W G12 12.0 75433.__

Light source Wattage Socket W [kg] Code

MH-T 70 W E27 10.5 75446.__SHP-T 70 W E27 10.5 75443.__MH 150 W G12 11.0 75431.__MH 250 W G12 12.0 75434.__

IP65 0.083 m2

integrated electromagnetic control gear

super spot optic

IP65 0.083 m2

integrated electromagnetic control gear

spot optic

Light source Wattage Socket W [kg] Code

MH-T 70 W E27 10.5 75447.__SHP-T 70 W E27 10.5 75444.__MH 150 W G12 11.0 75432.__MH 250 W G12 12.0 75435.__

IP65 0.083 m2

integrated electromagnetic control gear

flood optic

143

70W

MHRX7s

150W

MHRX7s-24

70W

SHPRX7s

150W

SHPRX7s-24

70W

MHRX7s

150W

MHRX7s-24

70W

SHPRX7s

150W

SHPRX7s-24

Ø 3

50

56

357

Ø 1

66

215

86 7932

spotlight Lux 350

Light source Wattage Socket W [kg] Code

MH / SHP 70 W RX7s 10.5 75450.__MH / SHP 150 W RX7s-24 11.0 75451.__

IP65 0.083 m2

integrated electromagnetic control gear

asymmetrical optic

Light source Wattage Socket W [kg] Code

MH / SHP 70 W RX7s 10.5 75448.__MH / SHP 150 W RX7s-24 11.0 75449.__

IP65 0.083 m2

integrated electromagnetic control gear

road optic

144

Ø 265

150

100 353

100

150

M12

13

150

18

86 7932

Lux 350 accessories

plate for floor and wall installationcode 75489.__

spikecode 75487.00

ring-shaped bafflecode 75485.00

refractor for elliptical projectioncode 75609.00

glare reduction visorcode 75488.__

filteryellow code 75606.00green code 75607.00 blue code 75605.00red code 75608.00

safety grillecode 75486.00

145

Lux 350

146

150W

MH-TE40

250W

MH-TE40

150W

SHP-TE40

150W

MH-TE40

250W

MH-TE40

150W

SHP-TE40

400W

MH-TE40

Ø38

7

60

416

Ø18

8

249

Ø38

7

60

461

Ø 1

88

265

86 7932

Lux 400 spotlight

Light source Wattage Socket W [kg] Code

MH-T / SHP-T 100 W E40 13.5 75461.__MH-T 150 W E40 14.0 75463.__SHP-T 150 W E40 14.0 75457.__MH-T 250 W E40 15.0 75465.__

Light source Wattage Socket W [kg] Code

MH-T / SHP-T 100 W E40 13.5 75462.__MH-T 150 W E40 14.1 75464.__SHP-T 150 W E40 15.0 75458.__MH-T 250 W E40 15.0 75466.__

IP65 0.149 m2

integrated electromagnetic control gear

spot optic

IP65 0.149 m2

integrated electromagnetic control gear

flood optic

Light source Wattage Socket W [kg] Code

MH-T 400 W E40 16.0 75467.__

IP65 0.158 m2

integrated electromagnetic control gear

flood optic

OSRAM HQI-T 400/N/SI C.L. 3.25 A lamp. Martini code 4.96095.57Colour variations may occur in vertical operating position with attachment facing downwards.

147

Ø316

150

100 353

100

150M

12

13

168

12

86 7932

accessories Lux 400

plate for floor and wall installationcode 75489.__

spikecode 75487.00

refractor for elliptical projectioncode 75614.00

glare reduction visorcode 75493.__

yellow filter code 75611.00green filter code 75612.00 blue filter code 75610.00red filter code 75613.00

safety grillecode 75491.00

148

Twin 1 arm

tie rod attachment pole-arm attachment

spotlight aim adjustment rotation options

149

1150

650

1280

860

2300

860

1145

1300

1280

1145

Ø

H

Ø

H

86 7932

arm Twin 1

double Twin 1 arm code 78045.__

single Twin 1 armcode 78042.__

double joint Ø 60 H = 155 78001.__Ø 89 H = 155 78005.__Ø 102 H = 155 78009.__Ø 120 H = 155 78013.__Ø 142 H = 180 78017.__Ø 171 H = 180 78021.__

Ø 60 H = 155 78000.__Ø 89 H = 155 78004.__Ø 102 H = 155 78008.__Ø 120 H = 155 78012.__Ø 142 H = 180 78016.__Ø 171 H = 180 78020.__

single joint

+ + +

guide to ordering

fixture pole page 206 joint (1-piece pack) arm

150

Twin 2 arm

tie rod attachment

pole-arm attachment

spotlight aim adjustment

rotation options

151

Ø

H

Ø

H

940

1320

1145

1320

1145

1880

86 7932

arm Twin 2

double Twin 2 armcode 78044.__

single Twin 2 arm code 78041.__

double joint Ø 60 H = 155 78001.__Ø 89 H = 155 78005.__Ø 102 H = 155 78009.__Ø 120 H = 155 78013.__Ø 142 H = 180 78017.__Ø 171 H = 180 78021.__

Ø 60 H = 155 78000.__Ø 89 H = 155 78004.__Ø 102 H = 155 78008.__Ø 120 H = 155 78012.__Ø 142 H = 180 78016.__Ø 171 H = 180 78020.__

single joint

+ + +

guide to ordering

fixture pole page 206 arm joint (1-piece pack)

152

Twin 3 arm

tie rod attachment

pole-arm attachment

spotlight aim adjustment

rotation options

153

1150

860

1145

860

1145

2300

Ø

H

Ø

H

86 7932

arm Twin 3

double Twin 3 arm code 78043.__

single Twin 3 armcode 78040.__

double joint Ø 60 H = 155 78001.__Ø 89 H = 155 78005.__Ø 102 H = 155 78009.__Ø 120 H = 155 78013.__Ø 142 H = 180 78017.__Ø 171 H = 180 78021.__

Ø 60 H = 155 78000.__Ø 89 H = 155 78004.__Ø 102 H = 155 78008.__Ø 120 H = 155 78012.__Ø 142 H = 180 78016.__Ø 171 H = 180 78020.__

single joint

+ + +

guide to ordering

fixture pole page 206 arm joint (1-piece pack)